Jharkhand Bijli Vitran Nigam Limited - Jharkhand
40979624 tender for manufacturing, testing and supply of super enamelled aluminum winding wire...
40979624 tender for manufacturing, testing and supply of super enamelled aluminum winding wire...
40958432 supply of electric line materials under o&mhead for f.y. 2023 24 ms base plate for 33 kv , earthing ( chemical ) with gi earthing pipe 40 mm 3.1 mtrs. long ( bentonite as intermittent layers ) , earthing ( chemical ) with gi earthing pipe 20 mm 2.5 mtrs. long , lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg , stay set complete for dss with wire , stay set complete ( 1800x16 mm ) with stay wire 7 / 10 swg 8 kgs & guy insulator ) , stay set complete ( 1900x20 mm ) with stay wire 7 / 10 swg 8 kgs & guy insulator ) , gi wire 8 swg , gi wire no. 10 for earthing , gi stay wire 7 / 16 for earthing , m.s nuts & bolts of different size , fabricated items ( galvanized ) , 33 kv angle stay clamp ( 50x6mm ) [ galvanized ] , earth clamp for earth wire ( 50 x 6 mm ) [ galvanized ] , gi earthing pipe 3.1 meter long ( 40 mm dia ) , aluminum pipe 40 mm dia , aluminum winding wire...
40824831 supply of 1 ms base plate for 33 kv 2 earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) 3 earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long 4 lt stay set complete (1700x16 mm) with stay wire 7/12 swg 5 stay set complete for dss with wire 6 stay set complete (1800x16 mm) with stay wire 7/10 swg 8 kgs & guy insulator) 7 stay set complete (1900x20 mm) with stay wire 7/10 swg 8 kgs & guy insulator) 8 gi wire 8 swg 9 gi wire no. 10 for earthing 10 gi stay wire 7/16 for earthing 11 m.s nuts & bolts of different size 12 fabricated items (galvanized) 13 33 kv angle stay clamp (50x6mm) [galvanized] 14 earth clamp for earth wire (50 x 6 mm) [galvanized] 15 gi earthing pipe 3.1 meter long (40 mm dia) 16 aluminum pipe 40 mm dia 17 aluminum winding wire...
40380713 supply of corona resistant round enamelled winding wire grade 2 size 20 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0. [ warranty period: 30 months after the date of delivery ] electric loco shed stores / tata, jharkhand 300.00 kg...
40352718 supply of corona resistant round enameled winding wire 20 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso / 2014 / el / spec / 0116 ( rev. 0 ) ( issued on august 2014 ) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] electric loco shed stores / tata, jharkhand 500.00 kg...
40174751 supply of corona resistant round enameled winding wire 18.5 swg, conforming to rdso smi no. rdso/2006/el/smi/0239 (rev. 0) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso/2014 /el/spec/ 0116 (rev. 0) (issued on august 2014) for corona resistant round copper enameled winding wires.corona resistant round enameled winding wire 18.5 swg, conforming to rdso smi no. rdso/2006/el/smi/0239 (rev. 0) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso/2014 /el/spec/ 0116 (rev. 0) (issued on august 2014) for corona resistant round copper enameled winding wires.,corona resistant round enameled winding wire 18.5 swg, conforming to rdso smi no. rdso/2006/el/smi/0239 (rev. 0) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso/2014 /el/spec/ 0116 (rev. 0) (issued on august 2014) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] electric loco shed stores/tata , jharkhand 400.00 kg...
39229730 supply of corona resistant round enameled winding wire 18 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso / 2014 / el / spec / 0116 ( rev. 0 ) ( issued on august 2014 ) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] electric loco shed stores / tata , jharkhand 250.00 kg...
38908272 bids are invited for copper winding wire se copper wire, swg 15 , se copper wire, swg 16 , se copper wire, swg 17 , se copper wire, swg 18 , se copper wire, swg 19 , se copper wire, swg 20 , se copper wire, swg 21 , se copper wire, swg 22 total quantity : 700...
38744289 supply of corona resistant round enamelled winding wire grade 2 size 20 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0.corona resistant round enamelled winding wire grade 2 size 20 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0., corona resistant round enamelled winding wire grade 2 size 20 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0. [ warranty period: 30 months after the date of delivery ] ...
38661843 bids are invited for winding wire rope of winder for underground mine total quantity : 1000...
38642426 supply of thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 20 swg. specn. no. is 13730part 13 / 1993. [ warranty period: 30 months after the date of delivery ] ...
38259868 auction sale of srl no [ 1 ] lot no ctrc / copper / 22 23 / p&eq, desc u / s released power & eq coil with insulation qty.2398.55 kgs, copper 2230.65 kgs, insulation 167.90 kgs. [ 2 ] lot no ctrc / copper / 22 23 / aux, desc u / s released aux. winding wire with insulation qty. 1722.2 kgs, copper 1601.65 kgs, insulation 120.55 kgs. srl no. [ 3 ] lot no ctrc / copper / 22 23 / copseg, desc u / s released copper segment & cut pieces ( pure copper ) , qty. 957.6 kgs., copper full....
37612451 supply of corona resistant round enameled winding wire 18.5 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso / 2014 / el / spec / 0116 ( rev. 0 ) ( issued on august 2014 ) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] ...
37457955 manufacturing, testing and supply of dpc al. winding wires & strips of assorted size dpc al. winding wires and strips of different size for repairing of distribution transformer of 25 kva, 63 kva, 100 kva and 200 kva , dpc al. winding wires & strips of assorted size , dpc al. winding wires & strips of assorted size , dpc al. winding wires & strips of assorted size , dpc al. winding wires & strips of assorted size , dpc al. winding wires & strips of assorted size , dpc al. winding wires & strips of assorted size...
37411478 supply of corona resistant round enameled winding wire 17 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso / 2014 / el / spec / 0116 ( rev. 0 ) ( issued on august 2014 ) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] ...
37406346 e quotation for seeking firm rates for non schedule items for preparing estimates of annual repair and maintenance of water supply system and sanitation t rinpas, kanke, ranchi under d.w and s mechanical division, ranchi. , cost towards providing all labours tools & techniciansfor dismantling and disconnecting of 40 hp kirloskar make motor and taken out rotor from motor stator cutting removing burnt and damaged coil and after repairing refitting the same etc all complete. , cost towards full rewinding of 40 hp motor stator with supplying of super enameled round copper conductor suitable gauge class f insulating materials making all connection taping, varnishing with dr beck varnish all complete with deducting the cost of taken out scrap materials ( wt. of wire is 18.5kg approx ) . , s / f ball bearing skf make 6312&6309 at de&nde side of 40 hp kirloskar make motor including proper greasing all complete. , cost towards providing all labour tools and tackles for dismantling of 40 hp single stage kirloskar make c / f pump with changing damaged parts such as gm neck ring as per size and sample 2 nos. shaft sleeve 2 nos. shaft sleeve check nut 2 nos. making ci bearing housing as per size and sample 2 nos. supplying and fitting ball wearing skf make 6309 2nos. making supplying and fitting ms gland tightner as per size and sample 2 pair making citric motion of rotating unit assembling on lathe m / c etc all complete , cost towards repairing of 40 hp l&t motor starter by supplying and fitting l&t make 3 core ml 4 power contactor 45 amp. with auxiliary contractor complete set 2nos. supplying and fitting timer type lt 100 1nos., over load relay suitable range 1nos.etc all complete. , cost towards providing all labours tools & technicians for taking out damaged 250amp. tpn hrc fuse type disconnector main switch replacing new disconnector fuse unit with hrc fuse 1 set doing electrical connection and testing on full load after deducting the cost of taken out scrap materials , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 40 hp pump set. , cost towards providing all labour tools and tackles for dismantling and taken out damaged nr valve and s / f 4”dia c.i df nr valve heavy duty rating pn 1 isi marked on delivery pipe line with all work including cost of labour charge all complete testing on full load with deducting the cost of scrap materials. , cost towards supplying and laying 50 mm² x 3.5 core aluminium armoured cable from main switch to industrial panel. ( both sets ) . , cost towards supplying and laying 16 mm² x 3 core copper cable from panel to starter and starter to motor in bunch of two. ( both sets ) . , cost towards replacing damaged suction pipe by making supply & fitting 100 mm dia heavy duty m.s. suction pipe 10feet long both and 100 mm dia m.s. flange welding, 100mm dia long bend 1 no with nut bolt rubber insertion etc required for the job. , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge. , cost towards dismantling of 100 hp wpil make single stage c / f pump and taking out its rotating unit assembly with changing of damaged parts by new making s / f neck ring as per sample size 2 nos, c.i shaft sleeve as per sample size – 2nos, making s / f shaft sleeve check nut as per sample size – 2 nos , s / fball bearing skf 6309 2 nos and repairing of bearinghousing by welding turning machining as per bearing size 2 nos, c.i gland tightner as per sample size – 2nos including cost of reassembling of rotating unit assembly balancing rotating unit assembly and fitting the pump with supply of grease gland packing oil packing paper with transporting cost of rotating unit from p / plant to workshop and back , cost toward supplying fitting & changing of 100 hp jyoti make motor ball bearing skf 6316 at de side 1 no. and sk 6314 nde 1 no. with grease. , cost towards repairing of 100 hp l & t make f.a.s.d starter with s / f contactor set 2 sets ) , relay unit ( 85 135a ) 1set, timer unit 1 set, making new connection etc all complete. , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 100 hp pump set. , cost towards supplying and fitting mccb 630 amp. for bus bar make l&t schneider / bch , cost towards supplying and fitting mccb 250 amp. for bus bar make l&t schneider / bch , cost toward supplying fitting & changing 100mm dia cidf sluice valve ( pn 1 ) 1 set & cidf nr valve ( pn 1 ) 1 no. including fitting charge , cost toward supplying fitting & changing 150 mm dia ci foot valve hiding single leather flat and gun metal seating all complete. , submersible pump sets , cost towards providing all labour tools and technicians for dismantling and taken out 5hp submersible p / set with column pipe for bore well. , cost towards repairing of5 hp submersible pump with s / f norylimpeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i. suction casing, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.2 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , supplying all material such as 40 mm dia g.i. pipe medium quality 15 ft. long, charcoal salt etc. for making earthing station as per i.e. rule , cost towards replacement of old and damaged underground service line by supplying new overhead line 10 mm² 3core copper wire after the deduction of cost of scrap materials. , supplying and laying ( under and over ground ) 2 dia aqua gold weather proof pvc pipe from bore well to main rising pipe line ( damaged pipe replacement ) make supreme / isi mark ( both sets ) , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , cost towards s / f and changing of 2”dia upvc column pipe with heavy duty socket ( make supreme / paras ) for both sets. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. , providing all labour, tools tackles& technicians for lowering of 5hp submersible pump set with all accessories in the bore well , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 1 no ( 2 ) 40 mm dia nr valve – 1 no ( 3 ) 40 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape , supplying and installation suitable size panel board for 5 hp submersible pump including fixing on wall comprising of following points such as ( 1 ) d.o.l starter 1no. ( 2 ) hrc fuse – 3 no. ( 3 ) voltmeter with selector switch – 1 set ( 4 ) ammeter with selector switch – 1 set ( 5 ) phase indicating neon lamp – 3 nos. etc. all complete after the deduction of cost of scrap materials. , supplying and fitting union 1.5 dia , supplying and fitting elbow 1.5 dia , supplying and fittingtee 1.5 dia , supplying and fitting socket 1.5 dia , supplying and fitting upvc valve 1.5 dia , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge....
37326781 e quotation for seeking firm rates for non schedule items for preparing estimates.annual repair and maintenance of water supply system and sanitation at t.b. sanatorium itki under d.w. & s. mechanical division ranchi. annual repair and maintenance of water supply system and sanitation at t.b. sanatorium itki under d.w. and s. mechanical division ranchi. , provision leake repairing of different and size of upvc sch 80 pipe in place of existing / cracked and damaged pipe of isi approved make or equivalent make damaged pipe in trenchage and replacement of pipe and fitting so as to give. i m average cover over the socket of pipes with disposal of excavated earth within initial lead and lift and necessary fitting and earth work in backfilling and cutting pipe to size etc. all complete as per specification and direction of e / i. , leakage in 50 mm dia upvc pipe , leakage in 40 mm dia upvc pipe , leakage in 32 mm dia upvc pipe , leakage in 25 mm dia upvc pipe , leakage in 20 mm dia upvc pipe , provision leake repairing of different and size of upvc sch 80 pipe in place of existing / cracked and damaged pipe with red lead and yarn of following nominal bore screwed and socketed joints on wall, ceiling and floor including supplying and fitting on wall hooks or pipe clamp wooden plugs, cutting pipe to size and threading ends where necessary etc. all complete as per specification and direction of e / i. , leakage in 50 mm dia upvc pipe , leakage in 40 mm dia upvc pipe , leakage in 32 mm dia upvc pipe , leakage in 25 mm dia upvc pipe , leakage in 20 mm dia upvc pipe , supplying and flaxing u pvc ball valve of approved make all complete as per direction of e / i. , 50 mm dia u pvc ball valve , 40 mm dia u pvc ball valve , 32 mm dia u pvc ball valve , 25 mm dia u pvc ball valve , 20 mm dia u pvc ball valve , supplying of materials for c.p. bathroom fitting ( as per schedule rate ) to consumrtion day to day work. , 15mm dia c.p. bib cock ( long thread ) , 15mm dia c.p. pillar cock ( long thread ) , 15mm dia c.p. angular stop cock ( long thread ) , 15mm dia cp basin mixture , 15mm dia cp wall mixture , jet sprey , health faucet , bib cock spindle , a ) medium size , b ) large size , mirror , towel rail , soap dish , 32mm dia cp waste : , 32mm dia pvc waste pipe 750mm long with coupling : , 100mm dia c.p. jali : , 15mm dia and 45cm long pvc connection pipe : , sink waste , cistern ball cock , cistern handle , pvc water storage tank cover ( 2000 / 1000 l ) , 25mm dia ball cock set for pvc tank , cammod cover , m seal , waste pipe bundla , 10 lit pvc l / d cistern , flush bend , basin , supplying, fitting and fixing pvc pipes of approved make including supplying nails, clips and pvc washer cement & yarn for making plumber joints properly cutting pipe to sizes including earth work of scaffolding etc. where necessary etc. all complete as per specification and direction of e / i. , 100mm dia pvc sewer pipe , 75mm dia pvc sewer pipe , supplying and fixing pvc fitting of approved make confirming to isi including supplying nails and bobbins from making solvent cement solution or gasket joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of e / i. , 110mm swr nahani trap , 110mm swr plain bend , 110mm swr door bend , 110mm swr plain tee , 110mm swr door tee , 75mm swr plain bend , 75mm swr door bend , 75mm swr plain tee , 75mm swr door tee , supplying all materials , labours, tools and equipment for laying upvc pipesof approved make in trenches with upvc solvent solution with socket and screw joints and cutting pipe as per size and threading ends where necessary etc. all complete as per specification and direction of e / i. ( in trenches ) , 50mm dia. upvc schedule 80 pipe ( in trenches ) [ make supreme / ashirwad / paras ] , 25mm dia. upvc schedule 80 pipe ( in trenches ) [ make supreme / ashirwad / paras ] , 40mm dia. upvc schedule 80 pipe ( in wall&overground ) [ make supreme / ashirwad / paras ] , supplying and fixing upvc fittings of approved make all complete as per specification and direction of e / i. , a ) upvc elbow ( 90 degree ) 50mm dia. upvc , 40mm dia upvc , 25mm dia upvc , b ) tee plain 50mm dia. upvc , 40mm dia upvc , 25mm dia upvc , c ) reducing bush 50mm x 25mm dia. upvc. , 50mm x 40mm dia upvc , 40mm x 25mm dia upvc , d ) reducing tee 50mm x 25mm dia. upvc. , 40mm dia upvc , 25mm dia upvc , e ) upvc socket 50mm dia. upvc , 40mm dia. upvc , 25mm dia upvc , f ) union socket ( upvc ) 50mm dia. upvc , 40mm dia upvc , 25mm dia upvc , providing all material, equipment and wash out and cleaning of 2000 / 1000 litre pvc water storage tank including rubbing the wall of tank by the help of coconut, rushi and bleaching powder their washing by clean water all complete as per direction of e / i. , 3000 litre capacity hdpe w / s / tank 2 time x 3000 liter x 2 nos. = 12000.00 liter 2000 litre capacity hdpe w / s / tank 2 time x 2000 liter x 88 nos. = 372000.00 liter 1000 litre capacity hdpe w / s / tank 2 time x 1000 liter x 9 nos. = 18000.00 liter total = 402000.00 liter , 10 hp c / f pump set , cost for complete rewinding of 10 h.p sq. cage induction motor operated on 415v, 3 phase, 50 c / s 1460 rpm with supply fitting of super enameled copper wire and other required insulation materials, heating assembly of the motor and testing on load ( wt of burnt coil 5.5 kg ) , cost for dismantling of 10 h.p c / f pump checking and changing of its damaged parts such as pump shaft of en 9 materials 01 no. key 02 nos. gland tightner 2 sets, gland tightner stud 4 nos. c.i bearing housing with cap 2 sets, ball bearing 6306 ( skf ) 2 nos. casing stud 16 mm sq. x 80 mm long with nut 8 nos. packing paper. grease, gland packing etc all complete and testing on load. , cost for supply and fitting of 3 dia tyre coupling complete set with nut, bolt & tyre. all complete. , cost for supply and fitting of 4 dia g.m flap tyre foot valve with packing and nut & bolt 4 nos. etc all complete. , cost for supply and fitting of 3 dia cidf heavy duty sluice valve, isi marked , cost for overhauling and repairing of motor control panel and changing of its damaged parts such as contactor ( ml 4 ) 3 nos., vm 02 nos., am 01, selector switch 2 nos, 100 amp mccb – 1 no, etc all complete and testing on load. , 3 h.p. submersible p / set , providing all labour, tools, tackles and technicians for taking out 3 h.p. submersible pump set with column pipe for bore well , cost towards for rewinding and repairing of 3 h.p submersible motor with s / f suitable winding wire, bronze bush etc. all complete after the deduction of cost of scrape materials. , cost towards repairing of 3 h.p. submersible pump with s / f bronze impeller as per size and sample, bush, thrust plate, pump shaft etc. all complete after the deduction of cost of scrape materials. , cost towards replacement of damaged submersible cable by supplying and fitting 2.5 mm2x 3 core flat submersible cable including cable jointing all complete for both set. after the deduction of cost of scrape materials. , cost towards supplying fitting, changing 2” dia g.i. column pipe with heavy duty socket ( make zindal / tata ) after the deduction of cost of scrape materials. , cost towards supplying and fitting ( 1 ) 2 dia g.m. full way valve – 1 no ( 2 ) 2 dia nr valve – 1 no ( 3 ) 2 dia g.i. bend 2 nos. ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape materials. , providing all labour, tools tackles and technicians for lowering of 3 h.p submersible pump set with all accessories in the bore well , 5 h.p. / 7.5 h.p. submersible p / set , providing all labour, tools, tackles and technicians for taking out 5 h.p. submersible pump set with column pipe ( 280 ) from bore well , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.0 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , cost towards repairing of 5 hp submersible pump with s / f noryl impeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. , cost towards supplying fitting, changing 2” dia g.i. column pipe with heavy duty socket ( make zindal / tata ) after the deduction of cost of scrape materials. , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 2 no ( 2 ) 50 mm dia nr valve – 1 no ( 3 ) 50 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt – 2 pair after the deduction of cost of scrape materials. , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , providing all labour, tools tackles and technicians for lowering ( 280 ) of 5 h.p.submersible pump set with all accessories in the bore well , supplying and installation suitable size panel board for 5 h.p. submersible pump including fixing on wall comparising of following points such as ( 1 ) d.o.l starter – 1 no. ( 2 ) hrc fuse – 3 no. ( 3 ) volt meter with selector witch 1 set ( 4 ) ammeter with selection switch – 1 set ( 5 ) zindicating neon lamp – 3 no. etc. all complete after the deduction of cost of scrape materials....
37280077 supply of corona resistant round enameled winding wire 21 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi or rdso spec. no. rdso / 2014 / el / spec / 0116 ( rev. 0 ) ( issued on august 2014 ) for corona resistant round copper enameled winding wires. [ warranty period: 30 months after the date of delivery ] ...
37062876 supply of corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 17 swg, etc.corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 17 swg, etc., corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 17 swg, conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi. [ warranty period: 30 months after the date of delivery ] ...
37042790 supply of corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 19 swg, (1.016 mm), etc.corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 19 swg, (1.016 mm), etc.,corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 19 swg, (1.016 mm), conforming to rdso smi no. rdso/2006/el/smi/0239 (rev. 0) & conforming to various tests listed out at point no. 6 of the same smi. [ warranty period: 30 months after the date of delivery ]...
37035964 supply of corona resistant round enameled winding wire grade 2 conveing with additional voltage endurance test of 2kv at 50hz size 18 swg, ( 1.219 mm ) , conforming to rdso smi no. rdso / 2006 / el / smi / 0239 ( rev. 0 ) & conforming to various tests listed out at point no. 6 of the same smi. [ warranty period: 30 months after the date of delivery ] ...
36384920 supply of thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 18 swg ( 1.219mm ) as per rdso specn. no. rdso / 2014 / el / spec / 0116 ( rev 0 ) . [ warranty period: 30 months after the date of delivery ] electric loco shed jharkhand 830.00 kg...
36379960 supply of thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 19 swg ( 1.016mm ) as per rdso specn. no. rdso / 2014 / el / spec / 0116 ( rev 0 ) . [ warranty period: 30 months after the date of delivery ] electric loco shed jharkhand 751.00 kg...
36048058 supply of corona resistant round enamelled winding wire grade 2 size 20 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0. [ warranty period: 30 months after the date of delivery ] electric loco shed jharkhand 125.00 kg...
36046858 supply of corona resistant round enamelled winding wire grade 2 size 18.5 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0 and conforming to various tests listed out at point no 6 of same document. [ warranty period: 30 months after the date of delivery ] electric loco shed jharkhand 25.00 kg...
36046120 supply of corona resistant round enamelled winding wire grade 2 size 18 swg conforming to rdso special maintenance instruction no. rdso / 2006 / el / smi / 0239, rev 0 and conforming to various tests listed out at point no 6 of same document. [ warranty period: 30 months after the date of delivery ] electric loco shed jharkhand 125.00 kg...
35796656 auction sale of unserviceable and scrap [ 1 ] lot no ctrc / copper / 22 23 / 01, desc released & u / s power & eq. coil with insulation, qty 5411.9 kgs. [ copper 5033.067 kg, insulation 378.833 kg ] , [ 2 ] lot no ctrc / copper / 22 23 / 02, desc aux. winding wire with insulation , qty 2475.4 kgs. [ copper 2302.122 kg, insulation 173 .278 kg ] , [ 3 ] lot no ctrc / copper / 22 23 / 03, desc copper segment & cut pieces, qty 681.8 kgs.. [ copper 681.80 kg ] , [ 4 ] lot no ctrc / copper / 22 23 / 04, desc cut pieces of power & eq. coil, qty 63 kgs. [ copper 62.685 , insulation 0.315 kg ] , ...
34911438 supply of thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 18.5 swg. specn. no. is 13730 part 13 / 1993.thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 18.5 swg. specn. no. is 13730 part 13 / 1993., thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 18.5 swg. specn. no. is 13730 part 13 / 1993. electric loco shed jharkhand 120.00 kg...
34910549 supply of thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 19 swg. specn. no. is 13730 part 13 / 1993.thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 19 swg. specn. no. is 13730 part 13 / 1993., thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 19 swg. specn. no. is 13730 part 13 / 1993. electric loco shed jharkhand 751.00 kg...
34910071 supply of thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993.thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993., thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993. electric loco shed jharkhand 830.00 kg...
34278542 supply of thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage enduranee test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage enduranee test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993, thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage enduranee test of 2kv at 50hz. size 18 swg. specn. no. is 13730 part 13 / 1993 electric loco shed jharkhand 125.00 kg...
34278230 supply of thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 18.5 swg. specn. no. is 13730part 13 / 1993.thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 18.5 swg. specn. no. is 13730part 13 / 1993., thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 18.5 swg. specn. no. is 13730part 13 / 1993. electric loco shed jharkhand 25.00 kg...
34278091 supply of thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 20 swg. specn. no. is 13730part 13 / 1993.thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 20 swg. specn. no. is 13730part 13 / 1993., thermax 200 cr type round enamelled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz size 20 swg. specn. no. is 13730part 13 / 1993. electric loco shed jharkhand 125.00 kg...
33496104 auction sale of disposal of 12nos. of scrap materials such as ( 1 ) released / defective over head copper wire assorted size qty=400kg ( cu ) ( 2 ) released / defective fan winding wire copper qty=50kg ( cu ) ( 3 ) released / defective burn out super enamled copper wire qty=195kg ( cu ) ( 4 ) released / defective brass stud qty=3.64kg ( brass ) ( 5 ) released / defective copper stud qty=2.180kg ( cu ) ( 6 ) broken & damaged impeller bronze & brass qty=46kg ( brass ) ( 7 ) defective ball & roller bearing all size qty=101kg ( fe ) ( 8 ) released / defective fan bush qty=0.39kg ( brass ) ( 9 ) scrap ferrous qty=1000kg ( fe ) ( 10 ) pvc insulated submersible winding wire copper qty=200kg ( cu=170kg, other=30kg ) ( 11 ) released 3 core flat submersible wire assorted size qty=22.8kg ( cu=9.8kg, other=13kg ) ( 12 ) pvc insulated aluminium wire assorted size qty=683.15kg ( al=170.78kg, other=512.36kg ) location dhn power house. [ i ] loading by the labour of purchaser, [ ii ] delivery on the basis of actual weight only....
33347859 bids are invited for super enamelled copper winding wire swg 15 , super enamelled copper winding wire swg 16 , super enamelled copper winding wire swg17 , super enamelled copperwinding wire swg 18 total quantity : 450...
33328845 rewinding of 85 hp 550 v , 500 gpm, 110 mtr head submersible motor woth supply of winding wire 3 sq mm high insulating copper wire and other insulating materials with accessories of submersible motor installed at centre pit moti muhallah , grd pro ...
33032072 auction sale of [ 1 ] desc ceiling fan 1200mm. ( defective & unserviceable ) , ledger reference rl 05 / 72, qty 83 nos., approx total weight 265.17 [ fe 245.348, cu 20.169 ] . [ 2 ] desc ceiling fan 1400 mm ( defective & unserviceable ) , ledger reference rl 05 / 72, qty 08 nos., approx total weight 32 [ fe 28.8, cu 3.2 ] . [ 3 ] desc ceiling fan 1500 mm ( defective & unserviceable ) , ledger reference rl 05 / 72, qty 07 nos., approx total weight 70 [ fe 65.45 cu 4.55 ] . [ 4 ] desc copper conductor wire zero size, ledger reference rl 05 / 71, qty 200 kg, approx total weight 200 [ fe 0 cu 200 ] . [ 5 ] desc fl fitting release & defective different size ( t 5, 28 w, led 20w, 40w ) , ledger reference rl 05 / 73, qty 34 nos., approx total weight 30 [ fe 30 cu 0 ] . [ 6 ] desc led release fitting outdoor street light defective & unserviceable, ledger reference rl 05 / 68, qty 300 nos., approx total weight 150 [ fe 150 cu 0 ] . [ 7 ] desc copper wire / winding wire release from defective submersible pump, ledger reference rl 05 / 67, qty 15 kg, approx total weight 15 [ fe 0 cu 15 ] . [ 8 ] desc hs meter defective all size ampere, ledger reference rl 05 / 65, qty 182 nos., approx total weight 87.14 [ fe 43.68 alu 43.68 ] . [ 9 ] desc mh fitting released 250w / 400w , ledger reference rl 05 / 61, qty 11 nos., approx total weight 59 [ fe 59 cu 0 ] . [ 10 ] desc exhust fan off size 380mm, 400mm, release, ledger reference rl_05 / 09, qty 27 nos, approx total weight 38 [ fe 26 cu 12 ] . [ 11 ] desc ball bearing off size, ledger reference rl 05 / 28, qty 43 nos, approx total weight 15 [ fe 15 cu 0 ] ....
32204586 auction sale of lot no: 60.0 lot name: old, used, winding wire rope (29 mm dia) in coils...
32120780 rewinding of 85 hp 550 v 500 gpm 110 mtr head submersible motor with supply of winding wire 3.0 mm high insulation winding wire and other insulating materials of submersible motor installed at centre pit and kamaljore for domestic water supply at grd rewinding of 85 hp 550 v 500 gpm 110 mtr head submersible motor with supply of winding wire 3.0 mm high insulation winding wire and other insulating materials of submersible motor installed at centre pit and kamaljore for domestic water supply at grd...
31955758 rate of materials supply of materials ( i ) rail pole 60 kgs 13 meter ( ii ) rail pole 52 kgs 13 meter ( iii ) rs joist pole 9.3 meter ( 175x85mm ) 19.6 kgs per mtr ( iv ) rs joist pole 9 meter ( 116x100mm ) 23 kgs per mtr ( v ) 125x70x5 rs gi joist 8mtr ( 13.3kg / mtr ) ( vi ) wpb 160x160, 30.4kg / m weather resistant h beam, 11m ( vii ) wpb 160x160, 30.4kg / m weather resistant h beam, 13m ( viii ) psc pole 400 kg w.l ( 9 mtr. ) ( ix ) psc pole 200 kg w.l ( 8 mtr. ) ( x ) steel tubular pole ( sp 32 ) of 9 meter ( xi ) steel tubular pole ( sp 55 ) of 11 meter ( xii ) steel tubular pole ( sp 72 ) of 13meter acsr conductors ( i ) acsr panther conductor ( 232 sq. mm ) ( ii ) acsr wolf conductor ( 150 sq. mm ) ( iii ) acsr dog conductor ( 100 sq. mm ) ( iv ) acsr racoon conductor ( 80 sq. mm ) ( v ) acsr rabbit conductor ( 55 mm2 ) ( vi ) acsr weasel conductor ( 34 sq. mm ) insulators & h / w fittings ( i ) 33 kv pin insulator 10 kn with pin ( porcelain type ) ( ii ) 33 kv polymer pin insulators 10 kn with gi pin and nut & washer ( iii ) 33 kv disc insulator ( polymer type ) 90 kn with h / w fitting and nut & washer ( iv ) 33 kv disc. insulator ( porcelain type ) 70 kn with h / w fitting ( v ) 33 kv disc insulator ( polymer type ) 70 kn with h / w fitting ( vi ) suspension hardware suitable for panther conductor ( vii ) tension hardware suitable for panther conductor ( viii ) 11 kv pin insulator 10 kn, od 40 mm dia with pin ( polymer type ) and nut & washer ( ix ) 11 kv pin insulator 5kn with pin ( porcelain type ) ( x ) 11 kv pin insulator 5 kn with pin ( polymer type ) and nut & washer ( xi ) 11 kv disc insulator ( polymer type ) 70 kn with h / w ( xii ) 11 kv disc insulator ( porcelain type ) 45 kn with h / w ( xiii ) 11 kv disc insulator ( polymer type ) 45 kn with h / w ( xiv ) lt pin insulator with pin ( porcelain type ) ( xv ) lt pin insulator ( porcelain type ) ( xvi ) lt shackle insulator ( porcelain type ) ( xvii ) lt shackle strip with bolts and nut ( xviii ) 33 kv post insulator 10 kn ( polymer ) ( xix ) 11 kv post insulator 5 kn ( polymer ) ( xx ) 33 kv stay insulator ( xxi ) 11 kv stay insulator ( xxii ) lt stay insulator ( xxiii ) mid span compression joints suitable for acsr panther conductor ( xxiv ) repairing sleeve suitable for acsr panther conductor isolator ( i ) 33 kv isolator 800 amp , 3 phase, with earth switch ( ii ) 33 kv isolator 800 amp , 3 phase, with out earth switch ( iii ) 33 kv isolator 630 amp, 3 phase, without earth switch ( iv ) 33 kv isolator 630 amp, 3 phase, with earth switch ( v ) 33 kv isolator 400 amp, 3 phase, with earth switch ( vi ) 11 kv isolator 630 amp, 3 phase, with earth switch ( vii ) 11 kv isolator 630 amp, 3 phase, without earth switch ( viii ) 11 kv isolator 400 amp, 3 phase, without earth switch ( ix ) 11 kv isolator 400 amp, 3 phase, with earth switch ( x ) 11 kv isolator 200 amp single phase ab switch ( i ) 33 kv 3 pin type, 3 phase, ab switch 800 amp ( porcelain type ) ( ii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( iii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( polymer type ) ( iv ) 11 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( v ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( polymer type ) ( vi ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( porcelain type ) ( vii ) 11kv ab switch 200 amps ( single break ) lightening arrestor ( i ) lightening arrestor ( 9kv 5ka ) line type ( ii ) 11 kv lightening arrester ( 9 kv, 10 ka class ii, station type ) ( 1set=3nos ) ( iii ) 33 kv lightening arrester ( 30kv, 10ka class ii, station type ) ( 1set=3nos ) earthing ( i ) 25mm dia ms rod 3 m long for earth mat ( ii ) spike earthing made of 20mm gi solid rod ( iii ) g.i earthing strip size 75x8 mm ( iv ) g.i earthing strip size 35x3 mm ( v ) g.i earthing strip size 35x4 mm ( vi ) g.i earthing strip size 40x4 mm ( vii ) g.i earthing strip size 40x5 mm ( viii ) insulated gi / alum.flexible wire 16 sq.mm ( ix ) ace chemrod ( artificial concept of earthing by chemical rod ) : ace chemrod earthing electrode ( consisting mild steel galvanised pipe of size 2500 mm in length x 48 mm outer dia. x 2 mm thick, ms rod of size 2575 mm x 16 mm be welded with bottom. the epoxy insulator of not less than 100 mm length is to be fixed on top of mild steel galvanised pipe. a highly conductive substance is to be filled in residual gap between pipe and rod ) with highly conductive substances not less than 25 kg for soil treatment ( x ) earthing complete conventional type having intermittent layer of charcoal and salt stay set ( i ) gi stay set complete for d / s / s ( 1900x 16mm ) with staywire 7 / 12 swg and guy insulator ( ii ) gi stay set complete for d / s / s ( 1900x 20mm ) with staywire 7 / 10 swg and guy insulator ( iii ) stay set complete ( 1800x20mm ) with stay wire 7 / 10 swg & guy insulator ( galvanised ) ( iv ) 11 kv stay set complete ( 1800x16 mm ) with stay wire 7 / 10 swg and guy insulator ( v ) lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg ( vi ) gi stay wire no. 7 / 8, 7 / 10, 7 / 12, 7 / 14, 7 / 16 p.g.clamps ( i ) p g clamp for 232 / 150 sq mm conductor ( ii ) p g clamp for 80 / 100mm2 ( iii ) p g clamps for 34 / 55mm2 ( iv ) bimettalic clamps for distribution transformers ht side ( 25 to 200 kva ) ( v ) bimettalic clamps for distribution transformers ht side above ( 200 kva ) ( vi ) bimettalic clamps for distribution transformers lt side ( 25 to 200 kva ) ( vii ) bimettalic clamps for distribution transformers lt side above ( 200 kva ) ( viii ) bimettalic clamps for power transformer 5 mva ( ix ) bimettalic clamps for power transformer 10 mva ( x ) bimettalic clamps for vcbs for 33kv and 11 kv ( xi ) bimettalic clamps for ct pt unit ( xii ) p g clamp 3 bolt for abt meters structures, gantry columns and base plates ( i ) structure for 33kv lightening arrestor [ non galvanized ] ( ii ) structure for 33kv lightening arrestor [ galvanized ] ( iii ) structure for 33 kv isolator ( galvanised ) ( iv ) structure for 11 kv isolator ( galvanised ) ( v ) structure for 33 kv isolator [ galvanized ] ( vi ) structure for 11 kv isolator [ galvanized ] ( vii ) structure for 33 kv pt ( non galvanised ) ( viii ) structure for 33 kv pt [ galvanized ] ( ix ) structure for 11 kv pt ( non galvanised ) ( x ) structure for 11 kv pt [ galvanized ] ( xi ) structure for post insulator for 11kv ( galvanised ) ( xii ) structure for post insulator for 33 kv [ galvanized ] ( xiii ) structure for 33 kv hg fuse set ( non galvanised ) ( xiv ) structure for 33 kv hg fuse set [ galvanized ] ( xv ) a swing bus structure ( xvi ) gantry column, girder structures for 33 / 11 kv pss for single transformer [ galvanized ] ( xvii ) a structures for top mounted ab switch on 33 kv bus [ galvanized ] ( xviii ) a structures for top mounted ab switch on 11 kv bus [ galvanized ] ( xix ) a structures for 11 kv take off with top mounted ab switch and provision of lightening arrester [ galvanized ] ( xx ) gi base plate for 33kv ( 500x500x10 mm ) avg weight 19.6kg / plate ( xxi ) stone base plate for 11 kv, dss, lt current and potential transformers ( i ) 33 kv ct outdoor oil immersed type, 3 core, 200 100 / 5 5 1 amp, class 0.5 for differential protection ( ii ) 33 kv ct outdoor oil immersed type, 3 core, 300 150 / 5 5 1 amp, class 0.5 for differential protection ( iii ) 33 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( iv ) 33 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( v ) 33 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vi ) 33 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vii ) 11 kv ct outdoor oil immersed type, 3 core, 600 300 / 5 5 1amp, class 0.5 for differential protection ( viii ) 11 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( ix ) 11 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( x ) 11 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xi ) 11 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xii ) 33 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) ( xiii ) 11 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) power transformer ( i ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( off load tap changer ) ( ii ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( on load tap changer ) ( iii ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( off load tap changer ) ( ivi ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( on load tap changer ) distribution transformer ( i ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 1 ( ii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 2 ( iii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 3 ( iv ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 4 ( v ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 5 ( vi ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 1 ( vii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 2 ( viii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 3 ( ix ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 4 ( x ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 5 ( xi ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 1 ( xii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 2 ( xiii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 3 ( xiv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 4 ( xv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 5 ( xvi ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 1 ( xvii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 2 ( xviii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 3 ( xix ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 4 ( xx ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 5 ( xxi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 1 ( xxii ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 2 ( xxiv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 3 ( xxv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 4 ( xxvi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 5 ( xxvii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxviii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxix ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxx ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxi ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxiii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating ; bis level 2 ( xxxiv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxxv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxvi ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxvii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxviii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxxix ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xl ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xli ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xlii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xliii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xliv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xlv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xlvi ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted ; bis level 5 distribution box ( i ) lt distribution box suitable for 500 kva transformer ( 800 a, isolator & 12 sp mccb of 160 a ) ( ii ) lt distribution box suitable for 400 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 315 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 200 kva transformer ( 400 a, isolator & 9 sp mccb of 160 a ) ( v ) lt distribution box suitable for 100 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( v ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( vii ) ltdb for 100kva & 63kva, isolator 250a, incoming mccb 4p, 200a, 36ka, outgoing mccb 3p 100a, 36ka ( viii ) ltdb for 25kva, isolator 63a, incoming mccb 4p, 63a, 20ka, outgoing mccb 3p 32a, 20ka ( ix ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & 6 tp mccb of 100 a ) ( x ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 6 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xi ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 9 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 3 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 5 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiv ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 8 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xv ) spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement vcb, c&r panel ( i ) 33 kv vcb, 1250 amp., outdoor type, 26.3 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 1200 600 300 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, with metering system in panel with numeric relay announciator ( ii ) 33 kv vcb, 1250 amp., outdoor type, 16 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 600 300 / 1 1a or 400 200 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( iii ) 11 kv vcb, outdoor type, 1250 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 1200 600 300 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va with metering system in panel ( iv ) 11 kv vcb, outdoor type, 800 a, for incoming, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( v ) 11 kv vcb, outdoor type, 630 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va ( vi ) 11 kv vcb, outdoor type, 400 a, for outgoing, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( vii ) indoor type control and relay panel for 33kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. ( viii ) indoor type control and relay panel for 33kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( ix ) indoor type control and relay panel for 11kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( x ) indoor type control and relay panel for 11kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. distribution board ( i ) 415v ac power distribution board ( ii ) 30v dc distribution board pipe connector ( i ) aluminium pipe connector ( ii ) connector pipe to panther ( iii ) connector panther to panther ( iv ) connector panther to ab switch ( v ) connector pipe to pipe ( vi ) connector pipe to dog ( vii ) connector pipe to ab switch ( viii ) connector dog to ab switch copper control cable ( i ) 2.5 mm2 copper 2 core control cable ( armoured ) ( ii ) 2.5 mm2 copper 2 core control cable ( unarmoured ) ( iii ) 2.5 mm2 copper 4 core control cable ( armoured ) ( iv ) 2.5 mm2 copper 4 core control cable ( unarmoured ) ( v ) 2.5 mm2 copper 6 core control cable ( armoured ) ( vi ) 2.5 mm² copper 6 core un armourd cable ( vii ) 7 core x 2.5 sq.mm. armoured control cable ( viii ) 2.5 mm2 copper 8 core control cable ( unarmoured ) ( ix ) 2.5 mm2 copper 10 core control cable ( armoured ) ( x ) 2.5 mm2 copper 10 core control cable ( unarmoured ) ( xi ) 2.5 mm2 copper 12 core control cable ( armoured ) ( xii ) 2.5 mm2 copper 12 core control cable ( unarmoured ) ( xiii ) 19 core x 2.5 sq.mm.armoured control cable capacitor bank ( i ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 3600 kvar ( ii ) 1815 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 kvar+726 kvar+726 kvar 12.1 kv bank shall be complete with capacitor units of 121 kvar at 6.98 kv including allied materials such as suitable size of aluminium busbars, pin / pos ( iii ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 1200 kvar ( iv ) 1089 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 metering equipment ( i ) 33 kv metering cubicle with pt & ct , 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( ii ) 33 kv outdoor type oil immersed ct pt combined metering unit 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( iii ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( modular rack mounted ) of different capacity ( iv ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( projection type ) of different capacity ( v ) 33 kv / 110 v, three phase four wire, ( 0.2s accuracy class for ct and 0.2 accuracy class for pt ) , ratio 1600 / 1a or 1200 / 1a ct pt combined metering unit for feeder ( vi ) metering panel, data concentrator unit ( dcu ) with modem ( vii ) structure for 33 kv metering unit ( viii ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.2s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( ix ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.5s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( x ) trivector energy meter of 800 / 5 amp ( xi ) trivector energy meter of 400 / 5 amp ( xii ) 11 kv, outdoor type oil immersed ct pt combined metering unit, 3 phase 4 wire ( 11kv / 110v ) [ 12 kv pt 50va burden 0.5s accuracy class; ct 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 15 va, 0.5 accuracy class ] ( xiii ) 11 kv metering cubicle with pt ratio 11kv / √3 / 110v and ct ratio 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 0.5 accuracy class for both ( xiv ) ltct electronic meter ( 200 / 150 / 100 / 5 ) 3 phase 4 wire with meter box, class 0.5s accuracy ( xv ) ac 3 phase, 4 wire, 40 200amp lt electronic trivector accuracy class 1.0 dlms compliant category a meter with inbuilt cts and inbuilt 4g with fall back option gprs modem ( xvi ) structure for d.t meter ( xvii ) ac 3 phase dtr meter complete set above 100kva 400 / 5a ( xviii ) lt electronic trivector meter 40 200 amp. ( xix ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 200 / 5a ( xx ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 5a ( xxi ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 5a ( xxii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 1a ( xxiii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 1a ( xxiv ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 1a ( xxv ) 11kv / 110, 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 5a ( xxvi ) 11 kv / 110 v 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 200 / 5 a ( xxvii ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 600 / 1a ( xxviii ) 11 kv / 110, 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 600 / 5 a ( xxix ) dlms compliant, single phase 2 wire 5 30 amp. 1.0 accuracy, class ac statics single phase meter with meter box ( xxx ) lt static energy meter, 3 phase 4 wire, direct connected, 100 amp. with meter box, class 1.0 accuracy ( xxxi ) three phase 4 wire ac static whole current meter, electronic energy meter with box ( 10 60 ) amp ( xxxii ) single phase electronic meter, two wire, 5 30 amp. class 1.0 accuracy with box ( xxxiii ) single phase rf meter with box as per is 13779 standards, dlms compliant ( xxxiv ) three phase rf meter with box as per is 13779 standards, dlms compliant ( xxxv ) single phase rs 232 / 485 prepaid energy meter ( xxxvi ) three phase rs 232 / 485 prepaid energy meter ( xxxvii ) single phase rf prepaid energy meter ( xxxviii ) three phase rf prepaid energy meter ( xxxix ) single phase gprs / gsm prepaid energy meter ( xl ) three phase gprs / gsm prepaid energy meter ( xli ) pvc cable gland sizes 20 mm, ( xlii ) pvc cable gland sizes 25 mm, ( xliii ) pvc cable gland sizes 32 mm ( xliv ) pvc cable gland sizes 40 mm ( xlv ) pvc cable gland sizes 50 mm ( xlvi ) pvc cable gland sizes 63 mm ( xlvii ) pvc cable gland sizes 75 mm ( xlviii ) single phase whole current smart meter ( 5 30 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( xlix ) three phase whole current smart meter ( 10 50 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( l ) three phase whole current smart meter ( 20 100 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( li ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 100 / 5 amp ) ( lii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 200 / 5 amp ) ( liii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio / 5 amp ) ( liv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for feeder ( ct raio / 5amp ) ( lv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. meter box ( ct raio / 5amp ) ( lvi ) field routers / collectors / dcu along with installation clamp and accessories complete ( lvii ) network interface card ( nic ) for smart meter ( lviii ) centralized management console with single 24 led monitor ( lix ) work station consoles with dual 24 led monitor along with operating system, antivirus & license ( lx ) network laserjet ( b / w ) photocopy, scanning and printing ( lxi ) a4 size inkjet / bubble jet printer ( lxii ) a3 size inkjet color printer / all in one color laserjet printer ( lxii ) l.t. ct ratio 50 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 100 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 200 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 300 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 400 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 500 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 600 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 800 / 5a, 5va, 0.5 accuracy for metering, epoxy casted gi service pipe ( i ) gi service pipe 25 mm diameter 3 mtr length ( ii ) gi service pipe 40 mm diameter 3 mtr length ( iii ) gi service pipe 60mm diameter 3 mtr length ( iv ) g.i. pipe 3 dia ring main units ( i ) 11 kv 3 way rmu, 2od + 1vl, one incomer + one breaker + one outgoing ( ii ) 11 kv 4 way rmu, 2od + 2vl, ( one incomer + two breakers + one outgoing ( iii ) 11 kv 5 way rmu, 2od + 3vl, ( one incomer + three breakers + one outgoing ) ( iv ) 11 kv 6 way rmu, 2od + 4vl, ( one incomer + four breakers + one outgoing xlpe insulated cables ( i ) 33 kv ht xlpe cable single core 630mm2 ( armoured ) ( ii ) 1c x 400mm2 cable ( 33 kv power cable ) ( iii ) 33 kv ht xlpe cable 3 core 400 sq mm ( armoured ) ( iv ) 33 kv ht xlpe cable 3 core 300mm2 ( armoured ) ( v ) 33 kv ht xlpe cable 3 core 240mm2 ( armoured ) ( vi ) 33 kv ht xlpe cable 3 core 185mm2 ( armoured ) ( vii ) 33 kv ht xlpe cable 3 core 150mm2 ( armoured ) ( viii ) 33 kv ht xlpe cable 3 core 120mm2 ( armoured ) ( ix ) 33 kv ht xlpe cable 3 core 95mm2 ( armoured ) ( x ) 33 kv ht xlpe cable 3 core 70mm2 ( armoured ) ( xi ) 33 kv ht xlpe cable 3 core 50mm2 ( armoured ) ( xii ) 11 kv 3 core x 35 sq. mm cable ( armoured ) ( xiii ) 11 kv xlpe cable single core 630mm2 ( armoured ) ( xiv ) 3core x 630sq mm ( 11 kv power cable ) ( xv ) 11 kv xlpe cable 3 core 400mm2 ( armoured ) ( xvi ) 11 kv xlpe cable 3 core 300mm2 ( armoured ) ( xvii ) 11 kv xlpe cable 3 core 240 mm2 ( armoured ) ( xviii ) 11 kv xlpe cable 3 core 185mm2 ( armoured ) ( xix ) 11 kv xlpe cable 3 core 150mm2 ( armoured ) ( xx ) 11 kv xlpe cable 3 core 120mm2 ( armoured ) ( xxi ) 11 kv xlpe cable 3 core 95mm2 ( armoured ) ( xxii ) 11 kv xlpe cable 3 core 70mm2 ( armoured ) ( xxiii ) 11 kv xlpe cable 3 core 50mm2 ( armoured ) ( xxiv ) 11 kv xlpe cable 3 core 25mm2 ( armoured ) ( xxv ) power cable for dt meter 120 sq.mm unarmoured ( xxvi ) power cable for dt meter 240 sq.mm unarmoured ( xxvii ) lt xlpe cable 4 core 16 mm2 ( armoured ) ( xxviii ) lt xlpe cable 4 core 16mm2 ( unarmoured ) ( xxix ) lt xlpe cable 4 core 25mm2 ( armoured ) ( xxx ) lt xlpe cable 3.5 core 300mm2 ( armoured ) ( xxxi ) lt xlpe cable 3.5 core 185mm2 ( armoured ) ( xxxii ) lt xlpe cable 3.5 core 120mm2 ( armoured ) ( xxxiii ) lt xlpe cable 3.5 core 95 mm2 ( armoured ) ( xxxiv ) lt xlpe cable 3.5 core 50mm2 ( armoured ) ( xxxv ) lt xlpe cable 3.5 core 25mm2 ( armoured ) ( xxxvi ) lt xlpe cable 2 core 16 mm2 ( armoured ) ( xxxvii ) lt xlpe cable 2 core 10mm2 ( armoured ) ( xxxviii ) lt xlpe cable 2 core 6mm2 ( armoured ) ( xxxix ) lt xlpe cable 1cx120 sqmm ( armoured ) ( xl ) lt xlpe single core cable 95 mm2 ( armoured ) ( xli ) lt xlpe single core cable 50 mm2 ( armoured ) ( xlii ) lt xlpe single core cable 25 mm2 ( armoured ) ( xliii ) lt xlpe cable 3.5 core 35 sq. mm. ( armoured ) ( xliv ) lt xlpe cable 3.5 core 70 sq. mm. ( armoured ) ( xlv ) lt xlpe single core unarmoured 1 x 400 sqmm pvc insulated cables ( i ) 3.5 core 300 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ii ) 3.5 core 240 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iii ) 3.5 core 185 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iv ) 3.5 core 150 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( v ) 3.5 core 70 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vi ) 3.5 core 35 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vii ) 2 core 16 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( viii ) 1 core 120 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ix ) lt pvc cable 3.5 core 95 mm2 ( armoured ) ( x ) lt pvc cable 3.5 core 10 mm2 ( armoured ) ( xi ) lt pvc cable 3.5 core 6 mm2 ( armoured ) ( xii ) lt pvc cable 2 core 16 mm2 ( armoured ) ( xiii ) lt pvc cable 2 core 10 mm2 ( armoured ) ( xiv ) lt pvc cable 2 core 6 mm2 ( armoured ) ( xv ) lt pvc cable 2 core 4 mm2 ( armoured ) ( xvi ) lt pvc cable 1 core 16 mm2 ( armoured ) ( xvii ) lt pvc cable 1 core 50 mm2 ( armoured ) ( xviii ) lt pvc cable 1 core 70 mm2 ( armoured ) ( xix ) lt pvc cable 1 core 150 mm2 ( armoured ) ( xx ) lt pvc cable 1 core 300 mm2 ( armoured ) ( xxi ) pvc single phase service cable 3.5 core 25 mm2 ( amoured ) ( xxii ) 2.5 sq mm twin core pvc service cable ( armoured ) ( xxiii ) 4 sq mm twin core pvc service cable ( unarmoured ) ( xxiv ) pvc single phase service cable 2 core 2.5 mm2 ( unamoured ) ( xxv ) pvc single phase service cable 2 core 6 mm2 ( unarmoured ) ( xxvi ) pvc three phase service cable 4 core 6 mm2 ( armoured ) ( xxvii ) pvc three phase service cable 4 core 8 mm2 ( armoured ) ( xxviii ) pvc three phase service cable 4 core 10 mm2 ( armoured ) ( xxix ) pvc three phase service cable 4 core 16 mm2 ( armoured ) ( xxx ) pvc three phase service cable 4 core 25 mm2 ( armoured ) ( xxxi ) pvc three phase service cable 4 core 10 mm2 ( unarmoured ) aerial bunched cables ( i ) 11 kv xlpe ht ab cable 3cx185mm2+240mm2 bare messenger ( ii ) 11 kv xlpe ht ab cable 3cx185mm2+150mm2 bare messenger ( iii ) 11 kv xlpe ht ab cable 3cx150mm2+120mm2 bare messenger ( iv ) 11kv xlpe ht ab cable 3cx120 mm2 + 95mm2 bare messenger ( v ) 11 kv xlpe ht ab cable 3cx95mm2+80mm2 bare messenger ( vi ) 11 kv xlpe ht ab cable 3cx70mm2+70mm2 bare messenger ( vii ) 11 kv xlpe ht ab cable 3cx50mm2+70mm2 bare messenger ( viii ) 11 kv xlpe ht ab cable 3cx35mm2+70mm2 bare messenger ( ix ) 11 kv xlpe ht ab cable 3cx35mm2+35mm2 bare messenger ( x ) lt xlpe ab cable 3cx120+1cx70+1cx16 mm2 ( xi ) lt xlpe ab cable 3cx95 sqmm + 1x70 sqmm+1x70 sq mm ( xii ) lt xlpe ab cable 3cx95+1cx70+1cx16 mm2 ( xiii ) lt xlpe ab cable 3x70+1x50+1x16 ( street light ) mm2 ( xiv ) lt xlpe ab cable 3cx50 sqmm + 1x35 sqmm+1x16 sq mm ( xv ) lt xlpe ab cable 3x50+1x25+1x35 mm2 ( xvi ) lt xlpe ab cables 1x16 ( ph ) + 1x25 ( bare condustor + 1x16 ( insulated street lighting ) mm2 ( xvii ) lt xlpe ab cable 3cx120+70mm2 ( xviii ) lt xlpe ab cable 3cx95+70mm2 ( xix ) lt xlpe ab cable 3cx50+35mm2 ( xx ) lt xlpe ab cable 3cx35+25mm2 ( xxi ) lt xlpe ab cable 3cx25+25mm2 ( xxii ) lt xlpe ab cable 3cx16+25mm2 ( xxiii ) lt xlpe ab cable 1cx16+25mm2 single phase ab cable accessories ( i ) 11 kv ab cable straight thru joint kit suitable for 35 70 sqmm ( ii ) 11 kv ab cable straight thru joint kit suitable for 95 120 sqmm ( iii ) 11 kv abc termination kit 35 70 sqmm ( iv ) 11 kv abc termination kit 95 120 sqmm ( v ) lt pre insulated mid span joint suitable 25 mm2 phases ( vi ) lt pre insulated mid span joint suitable 35 mm2 phases ( vii ) lt pre insulated mid span joint suitable 50 mm2 phases ( viii ) lt pre insulated mid span joint suitable 70 mm2 phases ( ix ) lt pre insulated mid span joint suitable 95 mm2 phases ( x ) lt pre insulated mid span joint suitable 120 mm2 phases ( xi ) pre insulated mid span joint suitable for 25 mm2 neutral messenger ( xii ) pre insulated mid span joint suitable for 35 mm2 neutral messenger ( xiii ) pre insulated mid span joint suitable for 50 mm2 neutral messenger ( xiv ) insulation piercing connector for db charging ( xv ) insulation piercing connector branching suitable for t joints ( xvi ) piercing connector for lt ab cable ( xvii ) insulation piercing connector type i ( main 16 95 mm2 & tap 4 50 mm2 ) ( xviii ) insulation piercing connector type ii ( main 16 120 mm2 & tap 16 120 sq mm ) ( xix ) satellite connector ( xx ) lt ab cable accessory, 1.1mtr. stainless steel strap if207 ( 20x0.7 ) ( xxi ) buckle for strap ( xxii ) suspension clamp with eyehook ( xxiii ) suspension clamp suitable for 25 70 sqmm baremessenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxiv ) suspension clamp suitable for 35 95 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxv ) suspension clamp suitable for 95 150 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxvi ) dead end clamp with eyehook ( xxvii ) dead end clamp suitable for 25 70 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxviii ) dead end clamp suitable for 70 95 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxix ) dead end clamp suitable for 95 150 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxx ) dead end clamp assembly suitable upto 25 sq.mm bare messenger ( 01 dead end clamp with bracket, 2 mtr. stainless steel straps, 02 nos. buckles ) ( xxxi ) suspension clamp assembly suitable for 95 mm2 bare messenger ( 01 nos. suspension clamp with bracket, 2 mtr. stainless stell straps 02 nos. buckles ( xxxii ) service main anchor clamp for proper support of service cable ( 4mm2 and 10 mm2 ) ( xxxiii ) eye hook ( xxxiv ) stainless steel strip of 20mmx1mmx1000mm with buckle clip fabricated items ( i ) hot dip galvanized fabricated iron material for 33 kv line, lt line & dss ( ii ) 33 kv pole top bracket 50x10 mm flat [ galvanized ] ( 2.5 kgs. ) ( iii ) 33 kv pole top bracket 65x65x6 mm [ galvanized ] ( 3.58 kgs. ) ( iv ) 33 kv pole top bracket [ non galvanized ] ( 2.9 kgs. ) ( v ) 11kv pole top bracket 50x8 mm [ galvanized ] ( 2.2 kgs. ) ( vi ) 11 kv pole top bracket 50x8 mm ( f type ) [ non galvanized ] ( 2.2 kgs, ) ( vii ) 11 kv f clamp / bracket ( 2.1 kgs. ) ( viii ) 11 kv fish plate ( 1.6 kgs. ) ( ix ) 33 kv fish plate ( for st pole 13 mtr. ) ( 3 kgs, ) ( x ) 33kv v cross arm for ( 100x50x6 mm ) [ galvanized ] ( 19.7 kgs. ) ( xi ) 33 kv v cross arm ( 100x 50x 6 mm ) [ non galvanized ] ( 19.7 kgs. ) ( xii ) 33 kv dp special type v cross arm [ galvanised ] ( 21 kgs. ) ( xiii ) 11kv v cross arm ( 100x50x6 mm ) , [ galvanized ] ( 16 kgs. ) ( xiv ) 11kv v cross arm ( 75x40x6 mm ) , [ galvanized ] ( 14.6 kgs. ) ( xv ) 11 kv v cross arm ( 75 x 40 x6 mm ) [ non galvanized ] ( 14.6 kgs. ) ( xvi ) ms angle ( 65x65x6 mm ) for guarding of 33 kv [ galvanized ] ( 16 kgs. ) ( xvii ) ms angle ( 65x65x6 mm ) for guarding of 11 kv [ galvanized ] ( 13.6 kgs. ) ( xviii ) ms angle ( 65x65x6 mm ) for guarding of 33 kv, 11 kv, l.t line [ non galvanized ] ( 13.6 kgs. ) ( xix ) top channel set ( 100x50x6 mm ) 3200 mm length [ galvanized ] ( 66.2 kgs. ) ( xx ) top channel set ( 100x50x6 mm ) [ non galvanized ] ( 66.2 kgs. ) ( xxi ) ms channel for ab switch ( 100x50x6 mm ) [ galvanized ] ( 28.16 kgs. ) ( xxii ) ms channel ab switch ( 100x50x6 mm ) [ non galvanized ] ( 28.16 kgs. ) ( xxiii ) 33kv d p channel ( 100x50x6 mm ) 3150 mm long [ galvanized ] ( 65.2 kgs. ) ( xxiv ) 33kv d p channel ( 100x50x6 mm ) 2200 mm long [ galvanized ] ( 45.5 kgs. ) ( xxv ) 33kv d p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] ( 26.9 kgs. ) ( xxvi ) 33 kv d.p channel ( 100x50x6 mm ) 1.3 meter [ non galvanized ] ( 26.9 kgs. ) ( xxvii ) 11kv d p channel ( 75x40x6 mm ) [ galvanized ] ( 41.3 kgs. ) ( xxviii ) 11kv d.p channel ( 75x40x6mm ) [ non galvanized ] ( 41.3 kgs. ) ( xxix ) transformer base channel ( 100x50x6 mm ) [ galvanized ] ( 52.63 kgs. ) ( xxx ) transformer base channel ( 100x50x6 mm ) [ non galvanized ] ( 52.63 kgs. ) ( xxxi ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ galvanized ] ( 52.3 kgs. ) ( xxxii ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ non galvanized ] ( 52.3 kgs. ) ( xxxiii ) belting angle a ( 65x65x6 mm ) [ galvanized ] ( 31 kgs. ) ( xxxiv ) belting angle b ( 65x65x6 mm ) [ galvanized ] ( 28 kgs. ) ( xxxv ) back clamp ( 50x6 mm ) for v xrm & & top bracket for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvi ) back clamp ( 50x8 mm ) for guarding angle for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvii ) back clamp ( 50x8 mm ) for guarding angle for 9 mtr. psc pole [ galvanized ] ( 3 kgs. ) ( xxxviii ) back clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 3.2 kgs. ) ( xxxix ) back clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 3.2 kgs. ) ( xl ) back clamp ( 50x8 mm ) for v xrm & top bracket for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xli ) back clamp ( 50x6 mm ) for v arm & top bracket 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xlii ) back clamp ( 50x6 mm ) for 9mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( xliii ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( xliv ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( xlv ) back clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 2 kgs. ) ( xlvi ) back clamp ( 50x6 mm ) for tublar pole [ non galvanized ] ( 2 kgs. ) ( xlvii ) support clamp for v cross arm for 60kg rail pole [ galvanized ] ( 1.6 kgs. each ) ( xlviii ) support clamp for v cross arm for 60kg rail pole [ non galvanized ] ( 1.6 kgs. each ) ( xlix ) support clamp for v cross arm for 9 mtr 400kg psc pole [ galvanized ] ( 1.2 kgs. each ) ( l ) support clamp for v cross arm for 9 mtr 400kg psc pole [ non galvanized ] ( 1.2 kgs. each ) ( li ) support clamp for v cross arm for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. each ) ( lii ) support clamp for v cross arm for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. each ) ( liii ) support clamp for v cross arm for tublar pole [ galvanized ] ( 1.4 kgs. each ) ( liv ) support clamp for v cross arm for tublar pole [ non galvanized ] ( 1.4 kgs. each ) ( lv ) back clamp a for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvi ) back clamp b for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvii ) back clamp for 33 kv dp special type v cross arm [ galvanised ] ( 3 kgs. each ) ( lviii ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ galvanized ] ( 3.7 kgs. ) ( lix ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ non galvanized ] ( 3.7 kgs. ) ( lx ) clamp for top channel 50x6 mm flat for 60kg rail pole [ galvanized ] ( 2.8 kgs. ) ( lxi ) clamp for top channel 50x6 mm flat for 60kg rail pole [ non galvanized ] ( 2.8 kgs. ) ( lxii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( lxiii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( lxiv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( lxv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( lxvi ) clamp for top channel 50x6 mm flat for tublar pole [ galvanized ] ( 2 kgs. ) ( lxvii ) clamp for top channel 50x6 mm flat for tublar pole [ non galvanized ] ( 2 kgs. ) ( lxviii ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 2.4 kgs. ) ( lxix ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 2.4 kgs. ) ( lxx ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( lxxi ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( lxxii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( lxxiii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( lxxiv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ galvanized ] ( lxxv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ non galvanized ] ( lxxvi ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ galvanized ] ( 19.3 kgs. ) ( lxxvii ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ non galvanized ] ( 19.3 kgs. ) ( lxxviii ) clamp ( 50 x 6 mm ) for transformer base channel [ galvanized ] ( 3.2 kgs. ) ( lxxix ) clamp ( 50 x 6 mm ) for transformer base channel [ non galvanized ] ( 3.2 kgs. ) ( lxxx ) clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] ( 1.872 kgs. ) ( lxxxi ) clamp ( 50 x 6 mm ) for transformer belting [ non galvanized ] ( 1.872 kgs. ) ( lxxxii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] ( 1.872 kgs. ) ( lxxxiii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ non galvanized ] ( 1.872 kgs. ) ( lxxxiv ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 60kg rail pole [ galvanized ] ( 2.25 kgs. each ) ( lxxxv ) d.p channel support clamp ( 50x6 mm ) ) for 60kg rail pole [ non galvanized ] ( 2.25 kgs. each ) ( lxxxvi ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.5 kgs. each ) ( lxxxvii ) d.p channel support clamp ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.5 kgs. each ) ( lxxxviii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.1 kgs. each ) ( lxxxix ) d.p channel support clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ nongalvanized ] ( 1.1 kgs. each ) ( xc ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ galvanized ] ( 4.5 kgs. each ) ( xci ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ non galvanized ] ( 4.5 kgs. each ) ( xcii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ galvanized ] ( 1.92 kgs. ) ( xciii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( xciv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( xcv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( xcvi ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( xcvii ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( xcviii ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ galvanized ] ( 1.8 kgs. ) ( xcix ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ non galvanized ] ( 1.8 kgs. ) ( c ) 33kv cross bracing for d p structure ( 50x50x6 ) [ galvanized ] ( 64.3 kgs. ) ( ci ) 33 kv cross bracing for dp channel [ non galvanized ] ( 64.3 kgs. ) ( cii ) 11 kv cross bracing for d p structure [ galvanized ] ( 51.7 kgs. ) ( ciii ) 11 kv cross bracing for d p structure [ non galvanized ] ( 51.7 kgs. ) ( civ ) clamp for cross bracing set of 2 pair for 60kg rail pole [ galvanized ] ( 1.872 kgs. each ) ( cv ) clamp for cross bracing set of 2 pair for 60kg rail pole [ non galvanized ] ( 1.872 kgs. each ) ( cvi ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ galvanized ] ( 1.3 kgs. ) ( cvii ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ non galvanized ] ( 1.3 kgs. ) ( cviii ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole [ galvanized ] ( 1.2 kgs. ) ( cix ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole non [ galvanized ] ( 1.2 kgs. ) ( cx ) clamp for cross bracing set of 2 pair for tublar pole [ galvanized ] ( 1.75 kgs. ) ( cxi ) clamp for cross bracing set of 2 pair for tublar pole [ non galvanized ] ( 1.75 kgs. ) ( cxii ) support clamp for cross bracing for 60kg rail pole [ galvanized ] ( 2.5 kgs. each ) ( cxiii ) support clamp for cross bracing for 60kg rail pole [ non galvanized ] ( 2.5 kgs. each ) ( cxiv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ galvanized ] ( 2.33 kgs. each ) ( cxv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ non galvanized ] ( 2.33 kgs. each ) ( cxvi ) support clamp for cross bracing for 8 mtr 200kg psc pole [ galvanized ] ( 1.68 kgs. each ) ( cxvii ) support clamp for cross bracing for 8 mtr 200kg psc pole [ non galvanized ] ( 1.68 kgs. each ) ( cxviii ) support clamp for cross bracing for tublar pole [ galvanized ] ( 2.1 kgs. each ) ( cxix ) support clamp for cross bracing for tublar pole [ non galvanized ] ( 2.1 kgs. each ) ( cxx ) angle / side stay clamp ( 50x8 mm ) for 13 mtr. stp pole [ galvanized ] ( 2.1 kgs. ) ( cxxi ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 1.92 kgs. ) ( cxxii ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( cxxiii ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( cxxiv ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( cxxv ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( cxxvi ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( cxxvii ) angle / side stay clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 1.92 kgs. ) ( cxxviii ) angle / side stay clamp ( 50 x 6 mm ) for tublar pole [ non galvanized ] ( 1.92 kgs. ) ( cxxix ) clamp for g.i. pipe ( 2.02 kgs. ) ( cxxx ) gi flat ( 75x6 mm ) [ galvanized ] ( 1.1 kgs. ) ( cxxxi ) ms flat ( 75x6 mm ) [ non galvanized ] ( 1.1 kgs. ) ( cxxxii ) earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] ( 1.8 kgs. ) ( cxxxiii ) earth clamp for earthwire ( 50 x 6 mm ) [ non galvanized ] ( 1.8 kgs. ) ( cxxxiv ) ms angle for lt distribution bus ( 50x50x6 mm ) [ galvanized ] ( cxxxv ) ms angle for l t distribution bus ( 50x50x6 mm ) [ non galvanized ] ( cxxxvi ) lt bracket vertical formation ( cxxxvii ) lt bracket for tapping point ( cxxxviii ) lt angle bracket ( 50x50x6 mm ) [ galvanized ] ( cxxxix ) lt angle bracket ( 50x50x6 mm ) [ non galvanized ] ( cxl ) pole clamp for i hook b type ( 0.8 kgs. each ) ( cxli ) lt back clamp ( 50 x 6 mm ) for lt angle [ galvanized ] ( 0.55 kgs. each ) ( cxlii ) lt back clamp ( 50 x 6 mm ) for lt angle [ non galvanized ] ( 0.55 kgs. each ) ( cvliii ) u clamp ( 40 x 6 mm ) [ galvanized ] ( 1.46 kgs. ) ( clxiv ) u clamp ( 40 x 6 mm ) [ non galvanized ] ( 1.46 kgs. ) ( clxv ) 50 x 6 mm galvanized gi flat ( risers ) ( clxvi ) 25 x 3 mm galvanized gi flat ( risers ) fuse ( i ) 11 kv d.o. fuse unit ( polymer type ) ( ii ) 33 kv d.o. fuse unit ( polymer type ) ( iii ) 33 kv h.g. fuse unit ( polymer type ) ( iv ) 11 kv h.g. fuse unit ( polymer type ) electrical conduit ( pipes ) ( i ) gi pipe 4 medium duty ( b class ) ( ii ) gi pipe 6 medium duty ( b class ) ( iii ) gi pipe 8 medium duty ( b class ) ( iv ) hume pipe rcc pipe 100 mm ( np2 class ) ( v ) hume pipe rcc pipe 150 mm ( np2 class ) ( vi ) hume pipe rcc pipe 200 mm ( np3 class ) ( v ) hdpe pipe 110 mm / 4 pe 63 grade ( vi ) hdpe pipe 160 mm / 6 pe 63 grade ( vii ) hdpe pipe 200 mm / 8 pe 63 grade heat shrinkable kit ( i ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 ( ii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 300 mm2 ( iii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 240mm2 ( iv ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 185 mm2 ( v ) 33 kv 3 core heat shrikable straight through cable jointing kit for 150 95 mm2 ( vi ) 33 kv 3 core heat shrikable straight through cable jointing kit for 70 35 mm2 ( vii ) 33 kv termination kit for 1core x 400mm2 ( viii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 400mm2 ( ix ) 33 kv 3 core heat shrinkable out door type cable termination kit for 300 mm2 ( x ) 33 kv 3 core heat shrinkable out door type cable termination kit for 240 mm2 ( xi ) 33 kv 3 core heat shrinkable out door type cable termination kit for 185 mm2 ( xii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 120 mm2 ( xiii ) 33 kv 3 core heat shrikable out door cable termination kit for 95 70 mm2 ( xiv ) 33 kv 3 core heat shrikable indoor cable termination kit for 400mm2 ( xv ) 33 kv 3 core heat shrikable indoor cable termination kit for 300 mm2 ( xvi ) 33 kv 3 core heat shrikable indoor cable termination kit for 240 mm2 ( xvii ) 33 kv 3 core heat shrikable indoor cable termination kit for 185 mm2 ( xviii ) 33 kv 3 core heat shrikable indoor cable termination kit for 120 mm2 ( xix ) 33 kv 3 core heat shrikable indoor cable termination kit for 95 70 mm2 ( xx ) 33 kv 3 core heat shrikable indoor cable termination kit for 50 25 mm2 ( xxi ) in door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxii ) out door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxiii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 400 mm2 ( xxiv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 300 mm2 ( xxv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 240 mm2 ( xxvi ) 11 kv 3 core heat shrinkable straight through cable jointing kit 185 mm2 ( xxvii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 95 150 mm2 ( xxviii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 70 35 mm2 ( xxix ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 400 mm2 ( xxx ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 300 mm2 ( xxxi ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 240 mm2 ( xxxii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 120 185 mm2 ( xxxiii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 95 50 mm2 ( xxxiv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 400 mm2 ( xxxv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 300 mm2 ( xxxvi ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 240 mm2 ( xxxvii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 120 185 mm2 ( xxxviii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 95 50 mm2 ug cables related material ( i ) pillar box cum consumer service distribution box one time lock system ( 1 no. 3 ph 4 wire incoming and 5 nos. 3ph 4 wire outgoing ) ( ii ) cable marker ( metal ) ab switch contact ( i ) male female contact of 33 kv ab switch 600 630 amp ( ii ) male female contact of 33 kv ab switch 400 amp ( iii ) male female contact of 33 kv ab switch 200 amp ( iv ) male female contact of 11 kv ab switch 800 amp ( v ) male female contact of 11 kv ab switch 600 amp ( vi ) male female contact of 11 kv ab switch 400 amp ( vii ) male female contact of 11 kv ab switch 200 amp testing equipment ( i ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt whole current single phase meters up to 60a ( ii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt 3 phase & ct operated energy meters ( iii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh for ht+ : to test meters suitable for ht, 3 phase, 3 wire and 4 wire systems ( iv ) eh ii chain electric hoist ( capacity 1 ton, standard lift 3 mtr ) with 1.5 hp motor ( v ) electronic weighing machine with 1.2x1.2 mtr. platform, suitable for weighing limit upto 2 tons ( vi ) electronic weighing machine with 2x2 mtr. platform, suitable for weighing limit upto 4 tons ( vii ) earth tester 200 amp. 2000 ohm ( digital ) ( viii ) 500 v megger ( ix ) 2.5 / 5 kv megger ( mannual ) ( x ) digital clamp meter ( meco 3150 ) ( xi ) digital tong tester ( 1000 amp., 500 v ) with associated accessories. ( xii ) digital multi meter ( 10 amp along with ma range ) ( xiii ) 2.5 kv motorised with range up to 20000 mega ohms ( xiv ) 2.5 kv motorised cum manual with range up to 20000 mega ohms ( xv ) 5 kv motorised with range up to 100000 mega ohms ( xvi ) 5 kv motorised cum manual with range up to 100000 mega ohms tool kit ( i ) adhesive insulation tape ( ii ) high temperature tape ( iii ) dicharge rod for 33 kv / 11kv ( iv ) screw driver set 840 ( v ) screw driver set 935 ( vi ) neon tester 813 ( vii ) hammer 200 gm ( viii ) hack saw frame ( ix ) hack saw blades ( x ) adjustable spanner ( xi ) wire stripper ( xii ) combinational plier ( xiii ) side cutting plier ( xiv ) measuring tape ( xv ) hand drill machine ( xvi ) punch ( xvii ) knife ( xviii ) spanner set ( xix ) tool bag ( xx ) nose plier ( xxi ) drill bit 3 / 10 concrete ( jk ) ( xxii ) chain pulley 5ton with 15 meter chain ( xxiii ) max pulley 10 ton civil works ( i ) opc cement scada related materials ( a ) scada server ( i ) fep server with interface switches for rtus and frtus ( ii ) isr server { data server } ( iii ) nms server { dms server } ( iv ) dts server ( only at ranchi ) ( v ) developmental server ( vi ) communication server ( vii ) web / directory server ( viii ) workstation with dual tft monitors ( ix ) led based video projection system with 2x3 module configuration with each module at least 67 diagonal with common projector ( x ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 1f ) ( xi ) 33 kv or 11 kv control and relay panel, scada compatable for transformer protection ( it ) with o / c +e / f + diff relay ( xii ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 2f ) ( xiii ) buchholz relay contact ( xiv ) minimum oil gauge ( xv ) scada compatible winding temp. indicator ( xvi ) scada compatible oil temp. indicator ( xvii ) rtu base equipment comprising panels, racks, sub racks, powe suppy modules, cpu, analog and digital input control output modules, interfacing mft using rs 485 modbus protocol and 2 ethernet ports + 4 serial ports ( rs232 / 485 ) , required a d converters and all other accessories required ( xviii ) dc voltage transducer ( xix ) rtu base and foundation ( base should be capable of withstanding 200 kg. load ) ( xx ) multi function transducers ( 5 amps, 110 v with rs 485 modbus communication protocol ) ( xxi ) type a frtu for 5 way rmus ( xxii ) type a frtu for 4 way rmus ( xxiii ) type b frtu for 3 way rmus ( xxiv ) type c frtu for 2 way rmus ( xxv ) routers 230 v ac, 2 ge ports, 48xfe, wan speed 200 mbps ( xxvi ) ethernet switch ( xxvii ) 2 mbps vpn link for connectivity for s / s with scada control center ( xxviii ) ldms ( xxix ) 2 kva ups ( for ldms ) with 160 ah battery, 72 v battery set ( xxx ) gsm / gprs modem along with accessories ( xxxi ) b / w laser printer for ldms ( xxxii ) 48 v dc power supply system based on smps for rtu & comm. equipment with 80 ah battery ( xxxiii ) cat 6 cable ( xxxiv ) ldms software ( xxxv ) numerical relay scada compatible for power transformer protection ( xxxvi ) numerical relay scada compatible for 33kv and 11 kv feeder protection ( xxxvii ) mcu module card ( xxxviii ) power module card ( xxxix ) di card ( xl ) do card ( xli ) ai card ( xlii ) com 6 card ( xliii ) rmu 3 way ( 1 incomer, 1 outgoing and 1 breaker ) scada compatible ( xliv ) rmu 5 way ( 1 incomer, 1 outgoing and 3 breakers ) scada compatible ( xlv ) 11 kv sectionalizer ( xlvi ) 11 kv auto reclosure ( xlvii ) gprs / cdma / edge / 3g modem ( xlviii ) heavy duty relay for cb trip / close ( 48 v dc, 2 no, 1 nc ) ( xlix ) 48 v dcps at rtu locations along with vrla batteries ( l ) 11 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( li ) 33 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( b ) storage & backup devices ( i ) external raid mass storage device ( for 2 months online backup ) ( ii ) external dat drive ( c ) switches ( i ) layer ii switch ( scada / dms lan ) ( 48 ports ) ( ii ) layer switch ( planning & development system lan ) ( 24 ports ) ( d ) other active devices ( i ) gps time synchronization system ( ii ) time, day & date digital displays ( e ) printers ( i ) a3 color inkjet printer ( ii ) b / w laser printer ( iii ) color laser printer ( f ) security system ( dmz ) ( i ) web server with load balancing ( ii ) firewall & network ids / ips in pair ( 2 nos. ) ( g ) cabling system ( i ) cable, jacks, hubs, etc. ( ii ) acdb for control centre ( iii ) kvm switch ( iv ) panels ( h ) software for control centre ( i ) scada software ( ii ) isr software ( iii ) dms software ( iv ) dts software ( v ) developmental software ( vi ) network management software ( viii ) gis adaptor / engine for importing data from gis system under it system ( i ) form: f 4: rtu:rtu type b 33 / 11 kv sub stations ( i ) rtu base equipment comprising panels, racks, sub racks, power supply modules, cpu, analog and digital input control output modules, interfacing equipments for interfacing mfts using rs 485 modbus protocol and 2 eathernet ports, required a d converters & all other required items / accessories including complete wiring for all modules for locations mentioned for type b rtus ( ii ) multifunction transducers ( mfts ) ( iii ) contact multiplying relays ( cmrs ) ( iv ) heavy duty relays ( hdrs ) for cb trip / close and rise and lower of oltc ( v ) weather transducer wind speed ( vi ) weather transducer rainfall ( vii ) weather transducer humidity ( viii ) weather transducer temperature ( ix ) weather transducer wind direction ( x ) router for rtus at dc power supply ( xi ) oltc transducers ( xii ) dc current transducer ( xiii ) dc voltage transducer ( xiv ) acdb with sufficient mccbs ( j ) test equipments for rtu ( i ) rtu database configuration & maintenance software tool ( ii ) master station cum rtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( k ) form: f 5:frtu / frtus ( i ) type a frtu for 5 way rmus ( ii ) type a1 frtu for 4 way rmus ( iii ) type b frtu for 3 way rmus ( iv ) type c frtu for sectionalizers ( v ) mfts ( vi ) contact multiplying relays ( cmrs ) ( vii ) heavy duty relays for cb trip / close ( l ) test equipments for frtu ( i ) frtu database configuration & maintenance software tool ( ii ) master station cum frtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( m ) f4: gprs / cdma / edge / 3gmodems ( i ) gprs ( n ) form: f 7: auxiliary power supply system ( aps ) ( i ) 20 kva ups ( 1+1 ) with vrla batteries to give 4 hrs back up ( ii ) dc power supply ( dcps ) system based on smps ( for 20 a load plus charging current@10% capacity ) with vrla batteries to give 4 hrs back up. ( iii ) 2 kva ups for rtu locations / ldms ( iv ) 48 v dcps at rtu locations along with vrla batteries ( v ) 24 / 48 v dcps for frtu locations along with vrla batteries safety equipment ( i ) rechargeable led hand torch ( ii ) safety helmet pvc ( iii ) safety shoes ( electrical safety ) ( iv ) rubber hand gloves ( 1.1kv ) commander ( v ) safety double adjustable belts ( karam ) ( vi ) safety items as per the requirement of electrical inspector as under first aid box, shock treatment chart, rubber matts 8 mm thick, 4 fire buckets with sand & m.s. hooks / stand, helmet, hand gloves and, fire extinguisher ( 2 nos ) fire extinguishers ( i ) i kg dry chemical powder ( map 50% ) ; fire rating : 1a, 8b ( ii ) 2 kg dry chemical powder ( map 50% ) ; fire rating: 2a, 8b ( iii ) 4 kg dry chemical powder ( map 50% ) ; fire rating : 2a, 21b ( iv ) 6 kg dry chemical powder ( map 50% ) ; fire rating: 3a, 34b ( v ) 9 kg dry chemical powder ( map 50% ) fire rating: 4a, 55b ( vi ) 6 ltr water type; fire rating : 2a ( vii ) 9 ltr water type, fire rating: 3a ( viii ) 6 ltr mechanical foam type, fire rating: 2a, 21b ( ix ) 9 ltr mechanical foam type, fire rating: 4a, 34b ( x ) 2 kg carbon dioxide type, fire rating: 8b ( xi ) 3 kg carbon dioxide type, fire rating: 13b ( xii ) 4.5 kg carbon dioxide type, fire rating: 21b ( xiii ) 6.5 kg carbon dioxide type, fire rating: 55b ( xiv ) 9 kg carbon dioxide type, fire rating: 70b ( xv ) 22.5 kg carbon dioxide type, fire rating: 70b ( xvi ) gas pressure ctc fire extinguisher ( xvii ) fire buckets ( capacity 10 ltrs. ) feeder pillar / smdb / distribution board ( i ) lt mini feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) ( ii ) smdb ( 1 in, 3 out ) with housing 5 nos 20 amp spn mcb, ( iii ) tpn distribution board 12 way, 50 amp tpn mcb, ( iv ) tpn distribution board 12 way, 100 amp tpn mcb, ( v ) tpn distribution board 12 way, 150 amp tpn mcb, ( vi ) lt feeder piller box for 1 phase 8 connection made of m.s.sheet. ( vii ) lt feeder piller box for 1 phase 12 connection made of m.s.sheet. ( viii ) lt feeder piller box for 3 phase 4 connection made of m.s.sheet. ( ix ) lt feeder piller box for 3 phase 8 connection made of m.s.sheet. ( x ) lt feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) aluminium end terminal lugs 10 sq mm 16 sq mm 25 sq mm 32 sq mm 50 sq mm 70 sq mm 95 sq mm 120 sqmm 150 sq mm 185 sq mm 225 sq mm 240 sq mm 300 sqmm 400 sq mm other misc. equipment ( i ) earthing g.i.strip ( 65x6 ) mm2 ( ii ) rain coat ( iii ) rubber mat along length of pannel ( iv ) aluminium pipe 40 mm dia ( v ) 400 watt / 250 v hpsv lamp fitting complete for 33 / 11 kv pss yard lightining ( vi ) 30 v 80 ah battery charging unit complete with battery and stand ( vii ) 30 volts 100 ah lead acid battery with battery charger and stand ( viii ) 30v, 40 amp. float cum boost battery charger with full wave rectification for 230 v, 1 phase, 50 hz ac input supply as per technical specifications. ( ix ) polycarbonate seal bit ( x ) sticker seal with hologram ( xi ) earth knob ( xii ) ms earth mat for switch yard ( xiii ) rail piece 44.64kg / m 6.92 meter long for power transformer ( xiv ) aluminium binding wire ( xv ) gi wire no. 6 / 8 / 10 ( xvi ) t / c fuse wire 12 / 14 / 16 / 18 / 22 / 28 / 32 swg ( xvii ) m s nuts & bolts of different size ( xviii ) galvanised nuts & bolts ( assorted size ) ( xix ) jointing sleeves ( alumnium ) suitable for 34 / 55 sq.mm ( xx ) jointing sleeves ( alumnium ) suitable for 70 100 sq.mm ( xxi ) jointing sleeves ( alumnium ) suitable for 150 232 sq.mm ( xxii ) anticlimbing device ( barbed wire ) 2x12 swg ( xxiii ) al paint ( xxiv ) red oxide paint ( xxv ) lt phase seperator ( xxvi ) 3 mm thick ms plate with weight of 0.36 kg asset tag ( xxvii ) transformer oil ( ehv grade ) ( xxviii ) natural ester oil ( xxix ) c wedge connector for 0.2sq panther conductor ( nominal aluminum area 200mm2 ) ( xxx ) fault locator machine for ug cables ( flc ) without vehicle ( xxxi ) transformer oil testing kit ( 220 / 230 ac ) ( xxxii ) transformer oil filter machine ( 500 gph ) ( xxxiii ) supply & installation of battery bank of 2 volt 300 ah vrla cells mounted on rack with insulated copper terminal connectors & nut boly ( each set of battery bank consist of 204 nos. vrla cells ) ( b ) furniture ( i ) thrive mid back revolving chair size:75cm ( w ) x 75cm ( d ) x 100cm 109cm ( h ) x 45cm 54cm ( seat height ) . ( ii ) thrive non revolving visitor chair size:63.5cm ( w ) x 59.5cm ( d ) x 97.5cm ( h ) x 42.5cm ( seat height ) . ( iii ) regency non revolving visitor chair with armrest size:59cm ( w ) x 63cm ( d ) x 81.5cm ( h ) x 45cm ( seat height ) . ( iv ) regency mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 78.5cm 90.5cm ( h ) x 44.2cm 54.2cm ( seat height ) . ( v ) bravo mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 85.5cm 97.5cm ( h ) x 42.5cm 54.5cm ( seat height ) . ( vi ) high back revolving chair size:76.1cm ( w ) x 76.1cm ( d ) x 114.5cm 131.5cm ( h ) x 44.5cm 54.5cm ( seat height ) . ( vii ) non revolving visitor chair size:60.9cm ( w ) x 64.7cm ( d ) x 98.2cm ( h ) x 46.2cm ( seat height ) . ( viii ) very high back revolving chair size:77cm ( w ) x 77cm ( d ) x 134.9cm 143.9cm ( h ) x 49.9cm 58.9cm ( seat height ) . ( ix ) non revolving visitor chair size:59cm ( w ) x 68.5cm ( d ) x 89.5cm ( h ) x 46.5cm ( seat height ) . ( x ) unlearn single seater cpu / laptop table for computer training hall size: 90cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xi ) unlearn 2 seater laptop table for meeting hall size:135cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xii ) unlearn 4 seater laptop table for meeting hall size:270cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xiii ) talk unitised 4 seater round table size:120cm dia x 75cm ( h ) ( xiv ) talk modular conference table size:67.5cm ( w ) x 60cm ( d ) x 75cm ( h ) ( xv ) enterprise table with cpu hanger size:165cm ( w ) x 90cm ( d ) x 72.8cm ( h ) ( xvi ) insight table for library size:180cm ( w ) x 90cm ( d ) x 74cm ( h ) ( xvii ) versatila v2 table for faculty sitting area size:150cm ( w ) x 89.4cm ( d ) x 75cm ( h ) ( xviii ) executive table with right unit and pedestal size:180cm ( w ) x 210cm ( d ) x 75cm ( h ) ( xix ) main desk table size: 180cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xx ) back unit for impress desk table size: 221.5cm ( w ) x 41cm ( d ) x 200cm ( h ) ( xxi ) display unit tv cabinet walnut color size: 140cm ( w ) x 40cm ( d ) x 75.4cm ( h ) ( xxii ) time out 4 seater pu coated dining table size: 113.5cm ( w ) x 117.5cm ( d ) x 75cm ( h ) ( xxiii ) café chair without armrest size: 52.5cm ( w ) x 55.8cm ( d ) x 84.5cm ( h ) x 45cm ( seat height ) ( xxiv ) apple dining table 6 seater glass top size: 160cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xxv ) silver dining chair size: 44.5cm ( w ) x 41.5cm ( d ) x 96cm ( h ) ( xxvi ) dark walnut dining chair size: 45cm ( w ) x 45cm ( d ) x 95cm ( h ) ( xxvii ) coffee table walnut color size: 100cm ( w ) x 65cm ( d ) x 45cm ( h ) ( xxviii ) 3 seater leatherite sofa size: 205.5cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxix ) 2 seater leatherite sofa size: 100cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxx ) single seater leatherite sofa size: 86cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxxi ) plain almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxii ) glass door storwel almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxiii ) single sided wood & steel book rack base unit size:90cm ( w ) x 30cm ( d ) x 189cm ( h ) ( xxxiv ) all steel periodical display rack size:90cm ( w ) x 45cm ( d ) x 183cm ( h ) ( xxxv ) 4 door bookcase ( without top ) size:91.4cmw x 32cm ( d ) x 174.2cm ( h ) ( xxxvi ) white board 4ft. x 3ft. with stand ( xxxvii ) l shaped workstation made of 19mm thk white mdf board with pvc edges.size:1800mm ( l ) + 1200mm ( l ) x 600mm ( d ) x 1200mm ( h ) meter box ( i ) poly carbonate weather proof outdoor type meter cover boxes for single phase meter size 315mm x 265mm x 130mm along with zinc plated clamps ( ii ) poly carbonate weather proof outdoor type meter cover boxes for three phase meters 445mm x 345mm x 170mm along with zinc plated clamps ( iii ) deep drawn m.s. sheet weather proof outdoor type meter cover box for single phase meter size 300mm x 250mm x 160mm along with zinc plated clamps ( iv ) deep drawn m.s. sheet weather proof outdoor type meter cover box for three phase meter size 500mm x 300mm x 160mm along with zinc plated clamps ( v ) metal box of ct 800 / 5 amp ( vi ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 400 / 5a ( vii ) meter box ( viii ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 800 / 5a ( ix ) metal box of ct 400 / 5 amp gas insulated switchgear s / s ( i ) 30kv, 10ka, metal oxide, station class, surge arrester ( scada compliant ) ( for 33kv incoming line, ht side of 2nos. power transformers and 33 / 0.433kv station transformer ) outdoor type with surge counter. ( ii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) with: breaker: 36kv, 1250 a, ( 25ka s.c. rating ) , 3 ph, indoor type breaker ( with 30v dc tripping / closing coil and associated control ) along with marshalling box, terminal connectors and required accessories complete as per applicable ts ct:36kv, 1 ph, 25ka ( 800^00 200 / 1 1 1 a ) indoor type current transformer, having three secondary cores ( protection & metering & current differential protection ) along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set = 3 nos. ) pts: 36kv, 1 ph, 33kv / 110 v, single core outdoor type potential transformer along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set= 3 nos. ) and digital ammeter / voltmeter / energy meter, o / c and e / f relay etc. the cable chamber shall have 3 nos., 20kv, 10 ka distribution class valve type lightning arresters and isolators of capacity given in ts. for feeder protection ( iii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between gis and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for bus coupler protection. ( iv ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 1a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between breakers and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for power transformer protection. ( v ) 11 kv indoor gas insulated switch gear panel ( scada compliants ) consisting of 1250 a, 25ka for 3 seconds, 3 ph, indoor type breaker along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for transformer protection ( vi ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for bus coupler protection ( vii ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for feeder protection ( viii ) remote terminal unit ( rtu ) & accessories with pc & connections with 30 nos. analog points for voltage, frequency, mw, mvar ; 3 positional analog points for oltc and 28 digital points for breaker and isolator status. ( ix ) flexible cu. earth bond 1cm dia & 500mm long, both end provision of socket suitable for m 16 bolts. ( x ) g 3 gi beam ( 5.05mtr long, consisting of 2 nos 150x75 x5.7mm ) for 33kv incoming line ( 2 nos. beam one for surge arrester and other for isolator, nominal unit wt 0.2 mt ) ( xi ) gi spikes with cone and gi ( 2 nos ) base plate 10mm ( 50x2500 mm gi pipe ) ( unit wt=0.04 mt ) ( xii ) 12 kv, 630 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , gang operated isolator along with earth switch and support insulators, operating mechanism, base channel, down pipe and all required accessories complete as per technical specifications, without earth switch for substation transformers. ( xiii ) 60 kg / mtr rail pole pieces 5.4 mts ( 2.7x2 ) 44.62 kg per mtr / transformer ( unit wt=0.240 mt ) ( xiv ) 2 tier 2 rows cable trench ( internal width 1500 mm, depth 680 mm, width 75x75x6 mm support angles fixed rcc column of 250 x 250 mm & with ladder type cable tray ( 45x45x5mm two angles at both side having welded flats of 25x5 mm at a gap of 150mm ) for power & control cable ( xv ) chequerred plate 1000x300x5.6mm thick for cable trench in side control room 12 mtr ( xvi ) overhead hoist beam mounted remote opertated for lifting of equipment of control room, capacity 5 tonnes ( xvii ) 36kv, 800 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , motorised indoor floor mounted off load isolator along with all required accessories complete as per technical specifications, scope of works and approved ( xviii ) external electrification in switch yard area including power receptacles, station yard lighting with 6 nos lighting pole ( fitted with 2x100 watts led flood light ) made of 11 meters high steel tubular poles ( is 2713 part i, ii iii ) of designation 410 – sp 60 and 6 nos light ( 1 x 250 w led ) on structure & control room complete as per technical specifications, approved drawings and scope of the work. ( xix ) internal electrification works of control room comprising of main distribution board, sub distribution boards, copper flexible multi conductor 2.5 sqmm wiring ( for light & fan ) / 4 sqmm wiring ( for power points ) , power and light points, conduits, fan / led lamps / tube fittings, exhaust fans, switches, sockets, 2mm thick, pvc 25mm dia conduits pipes in recess, plugs, miniature circuit breakers, seperate independent earthing ( 2 nos of 40mm gi pipe / 3 m long ) etc as required including dc emergency lighting and auto change over switch as per technical specifcations, approved drawings and scope of work. over head distance to fault locator ( offline ) with signature analyser. a ) accessories & laptop as per latest technical specifications tower line for river crossings ( i ) d type tower for 33kv, 11kv ( double circuit line ) ( 13.56mt each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( ii ) d type tower for 33kv, 11kv ( four circuit line ) ( 15.14mt ) ( double circuit tower +3meter extension each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( iii ) compression type tension hardware fitting for earth wire ( iv ) vibration damper suitable for 7 / 3.15 mm gi earth wire ( v ) 25x500 mm flexible cu. earth bond. covered conductor & accessories ( i ) acsr covered panther conductor ( 200 sq. mm ) ( ii ) acsr covered wolf conductor ( 150 sq. mm ) ( iii ) acsr covered dog conductor ( 100 sq. mm ) ( iv ) mid span joint ( 150 sq mm & 200 sq mm ) ( v ) suspension ties ( ( 150 sq mm & 200 sq mm ) ) ( vi ) tension clamp ( wedge type ) ( ( 150 sq mm & 200 sq mm ) ) ( vii ) insulation piercing connector ( bare to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( viii ) insulation piercing connector ( covered to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( ix ) insulation piercing connector with alumunium bail for earthing ( ( 150 sq mm & 200 sq mm ) ) ( x ) mid span joint ( 100 sq mm & 50 sq mm ) ( xi ) suspension ties ( ( 100 sq mm & 50 sq mm ) ) ( xii ) tension clamp ( wedge type ) ( ( 100 sq mm & 50 sq mm ) ( xiii ) insulation piercing connector ( bare to covered ) ( 100 sq mm & 50 sq mm ) ( xiv ) insulation piercing connector ( covered to covered ) ( 100 sq mm & 50 sq mm ) ( xv ) insulation piercing connector with aluminium bail for earthing ( 100 sq mm & 50 sq mm ) led lights and related items ( i ) led light 190w ( ii ) led light 120w ( iii ) led light 75w ( iv ) led light 40w ( v ) 18 watt led panel bulb with outer 205x205x25 mm sq. and 180x180 mm inner diesel generator sets ( three phase ) with amf panel ( i ) 10kva ( ii ) 20kva ( iii ) 30kva ( iv ) 40kva ( v ) 50kva ( vi ) 62.5kva ( vii ) 82.5kva ( viii ) 100kva ( ix ) 160kva trw related items ( i ) 1 / 2 l.t. brass studs ( ii ) 1 / 2 h.t. brass studs ( iii ) l.t bushing 3347 250 amp ( iv ) l.t. bushing 250 amp ( v ) kraft paper 4 mile ( vi ) insulating paper tap 2.0 mm ( vii ) press board 1 mm ( viii ) bakelite tube 3 / 8x1 / 2 ( ix ) empire sleeving size 4 mm ( x ) r.c. sheet 3 x2x1 / 2 mm ( xi ) inline connector 6 mm ( xii ) cotton tap 1 ( xiii ) r.c. strip ( xiv ) r.c. washer 50x28x2 ( xv ) silicagel breather 200 kva ( xvi ) m.seal ( xvii ) c.i.cap 1 8 1 / 2 ( xviii ) insulating paper top 2.5 mil 20 mm ( xix ) crap paper ( xx ) g.p. thinner ( xxi ) d.a. gray paint ( xxii ) white paint ( xxiii ) nylon washer 3 / 4 ( xxiv ) m.s. plug ( xxv ) l.t. al.strip 6.50x4.50 mm ( xxvi ) dpc aluminum winding wire ( xxvii ) dpc aluminum winding strip ( xxviii ) transformer testing bench panel for 10 kva to 500 kva distribution transformer with its installation & commissioning transformer repairing items ( i ) l.t bushing rod assembly of 750 kva transformer. ( ii ) h.t bushing rod assembly of 750 kva transformer. ( iii ) l.t bushing insulator of 750 kva transformer. ( iv ) h.t bushing insulator of 750 kva transformer. ( v ) l.t bushing gasket set of 750 kva transformer. ( vi ) h.t bushing gasket set of 750 kva transformer. ( vii ) tank gasket set of 750 kva transformer. ( viii ) silica gel breather of 750 kva transformer. ( ix ) arching horn of 750 kva transformer, ( x ) l.t bushing rod assembly of 500 kva transformer ( xi ) h.t bushing rod assembly of 500 kva transformer ( xii ) l.t bushing insulator of 500 kva transformer ( xiii ) h.t bushing insulator of 500 kva transformer ( xiv ) l.t bushing gasket set of 500 kva transformer ( xv ) h.t bushing gasket set of 500 kva transformer ( xvi ) tank gasket set of 500 kva transformer ( xvii ) silica gel breather of 500 kva transformer ( xviii ) arching horn of 500 kva transformer ( xix ) l.t bushing rod assembly of 400 kva transformer ( xx ) h.t bushing rod assembly of 400 kva transformer ( xxi ) l.t bushing insulator of 400 kva transformer ( xxii ) h.t bushing insulator of 400 kva transformer ( xxiii ) l.t bushing gasket set of 400 kva transformer ( xxiv ) h.t bushing gasket set of 400 kva transformer ( xxv ) tank gasket set of 400 kva transformer ( xxvi ) silica gel breather of 400 kva transformer ( xxvii ) arching horn of 400 kva transformer ( xxviii ) l.t bushing rod assembly of 315 kva transformer ( xxix ) h.t bushing rod assembly of 315 kva transformer ( xxx ) l.t bushing insulator of 315 kva transformer ( xxxi ) h.t bushing insulator of 315 kva transformer ( xxxii ) l.t bushing gasket set of 315 kva transformer ( xxxiii ) h.t bushing gasket set of 315 kva transformer ( xxxiv ) tank gasket set of 315 kva transformer ( xxxv ) silica gel breather of 315 kva transformer ( xxxvi ) arching horn of 315 kva transformer ( xxxvii ) l.t bushing rod assembly of 250 kva transformer ( xxxviii ) h.t bushing rod assembly of 250 kva transformer ( xxxix ) l.t bushing insulator of 250 kva transformer ( xl ) h.t bushing insulator of 250 kva transformer ( xli ) l.t bushing gasket set of 250 kva transformer ( xlii ) h.t bushing gasket set of 250 kva transformer ( xliii ) tank gasket set of 250 kva transformer ( xliv ) silica gel breather of 250 kva transformer ( xlv ) arching horn of 250 kva transformer ( xlvi ) l.t bushing rod assembly of 200 kva transformer ( xlvii ) h.t bushing rod assembly of 200 kva transformer ( xlviii ) l.t bushing insulator of 200 kva transformer ( xlix ) h.t bushing insulator of 200 kva transformer ( l ) l.t bushing gasket set of 200 kva transformer ( li ) h.t bushing gasket set of 200 kva transformer ( lii ) tank gasket set of 200 kva transformer ( liii ) silica gel breather of 200 kva transformer ( liv ) arching horn of 200 kva transformer ( lv ) l.t bushing rod assembly of 100 kva transformer ( lvi ) h.t bushing rod assembly of 100 kva transformer ( lvii ) l.t bushing insulator of 100 kva transformer ( lviii ) h.t bushing insulator of 100 kva transformer ( lix ) l.t bushing gasket set of 100 kva transformer ( lx ) h.t bushing gasket set of 100 kva transformer ( lxi ) tank gasket set of 100 kva transformer ( lxii ) silica gel breather of 100 kva transformer ( lxiii ) arching horn of 100 kva transformer ( lxiv ) l.t bushing rod assembly of 63 kva transformer ( lxv ) h.t bushing rod assembly of 63 kva transformer ( lxvi ) l.t bushing insulator of 63 kva transformer ( lxvii ) h.t bushing insulator of 63 kva transformer ( lxviii ) l.t bushing gasket set of 63 kva transformer ( lxix ) h.t bushing gasket set of 63 kva transformer ( lxx ) tank gasket set of 63 kva transformer ( lxxi ) silica gel breather of 63 kva transformer ( lxxii ) arching horn of 63 kva transformer ( lxxiii ) l.t bushing rod assembly of 25 kva transformer ( lxxiv ) h.t bushing rod assembly of 25 kva transformer ( lxxv ) l.t bushing insulator of 25 kva transformer ( lxxvi ) h.t bushing insulator of 25 kva transformer ( lxxvii ) l.t bushing gasket set of 25 kva transformer ( lxxviii ) h.t bushing gasket set of 25 kva transformer ( lxxix ) tank gasket set of 25 kva transformer ( lxxx ) silica gel breather of 25 kva transformer ( lxxxi ) arching horn of 25 kva transformer ab switch repairing item ( i ) jaw of air break switch 600a ( ii ) blade of of air break switch 600a ( iii ) post insulator of air break switch 600a ( iv ) bearing of air break switch 600a ( v ) phase coupling pipe of air break switch 600 a ( vi ) down pipe of air break switch 600 a ( vii ) operating handle of air break switch 600 a ( viii ) operating leaver of air break switch 600 a ( ix ) connector of air break switch 600 a ( x ) arching horn of air break switch 600 a ( xi ) jaw of air break switch 400a ( xii ) blade of of air break switch 400a ( xiii ) post insulator of air break switch 400a ( xiv ) bearing of air break switch 400a ( xv ) phase coupling pipe of air break switch 400 a ( xvi ) down pipe of air break switch 400 a ( xvii ) operating handle of air break switch 400 a ( xviii ) operating leaver of air break switch 400 a ( xix ) connector of air break switch 400 a ( xx ) arching horn of air break switch 400 a ( xxi ) jaw of air break switch 200a ( xxii ) blade of of air break switch 200a ( xxiii ) post insulator of air break switch 200a ( xxiv ) bearing of air break switch 200a ( xxv ) phase coupling pipe of air break switch 200 a ( xxvi ) down pipe of air break switch 200 a ( xxvii ) operating handle of air break switch 200 a ( xxviii ) operating leaver of air break switch 200 a ( xxix ) connector of air break switch 200 a ( xxx ) arching horn of air break switch 200 a vcb repairing item ( i ) trip coil of 33kv vcb ( ii ) trip coil of 11kv vcb ( iii ) closing coil of 33kv vcb ( iv ) closing coil of 11kv vcb ( v ) push button switch 5a ( vi ) test terminal block 5a ( vii ) 33 kv indoor current transformers of ratio as required suitable for metering and protection. ( viii ) 33 kv outdoor current transformers of ratio as required suitable for metering and protection. ( ix ) 11 kv indoor current transformers of ratio as required suitable for metering and protection. ( x ) 11 kv outdoor current transformers of ratio as required suitable for metering and protection. ( xi ) 33000 / 110 volts single phase voltage transformer indoor. ( xii ) 33000 / 110 volts single phase voltage transformer outdoor. ( xiii ) 11000 / 110 volts single phase voltage transformer indoor. ( xiv ) 11000 / 110 volts single phase voltage transformer outdoor. ( xv ) flush type switchboard mounting pattern 96x96 sq.mm m.i. voltmeter ( xvi ) voltmeter phase selector switch. ( xvii ) indicating lamps coloured red, amber and blue, white, green, etc. ( xviii ) auxiliary switch having minimum of 8 contacts, 4 normally open and 4 normally closed ( xix ) flush mounting pattern 96x96 sq.mm m.i. ammeter ( xx ) ammeter selector switch to indicate phase current ( xxi ) over current and earth fault numerical relay ( xxii ) automatic door illuminating lamps with switch ( xxiii ) 240 v, 100 w, ac single phase anti / condensation heaters, with thermostat ( 0 60 deg. c ) and switch. ( xxiv ) operation counter for vcb ( xxv ) bus bar spout epoxy casted r phase of 33kv indoor vcb ( xxvi ) bus bar spout epoxy casted y phase of 33kv indoor vcb ( xxvii ) bus bar spout epoxy casted b phase of 33kv indoor vcb ( xxviii ) circuit spout epoxy casted of 33kv indoor vcb ( xxix ) housing for vacuum interrupter of 33kv indoor vcb ( xxx ) drive insulator 33kv vcb ( xxxi ) release coil of 33kv indoor vcb ( xxxii ) bus bar spout epoxy casted r phase of 11kv indoor vcb ( xxxiii ) bus bar spout epoxy casted y phase of 11kv indoor vcb ( xxxiv ) bus bar spout epoxy casted b phase of 11kv indoor vcb ( xxxv ) circuit spout epoxy casted of 11kv indoor vcb ( xxxvi ) housing for vacuum interrupter of 11kv indoor vcb ( xxxvii ) drive insulator of 11kv vcb ( xxxviii ) release coil of 11kv indoor vcb ( xxxix ) vacuum interrupter of 33kv outdoor type ( xl ) vacuum interrupter of 33kv indoor type ( xli ) vacuum interrupter of 11kv outdoor type ( xlii ) vacuum interrupter of 11kv indoor type ( xliii ) buzzer / hooter ( xliv ) t n c switch mrt related items ( i ) fully automatic energy meter test bench with 0.02 class, 10 position, for testing of 1 ph & 3 ph energy meters with 5 years maintenance, accreditation from nabl and software updation. ( ii ) instrument transformer ( ct pt ) test system ( iii ) transformer turn ratio meter and measurement test kit ( iv ) transformer oil filtering machine 500 gph ( v ) circuit breaker operational analyzer ( vi ) 3 ph relay test kit with all necessary accessories ( vii ) primary injection kit 1000 a with relay testing facility ( viii ) ht coil winding machine its installation, testing & commissioning ( ix ) lt coil winding machine its installation, testing & commissioning ( x ) 03 ( three ) phase transformer winding resistance meter ( xi ) digital multimeter, 750v ( xii ) capacitance tan delta test set for transformer, motor and switchgear ( xiii ) capacitance tan delta test set for cables ( xiv ) vaccum interrupter tester ( xv ) secondary injection kit ( xvi ) digital ht earth tester ( xvii ) 3 ph power quality analyser ( xviii ) 05 kv insulation tester ( manual ) ( xix ) 10 kv insulation tester ( motarized ) ( xx ) digital clamp meter; 20 1000a, 200 v dc ( xxi ) digital clamp meter; 20a ( 1ma 20a ) ( xxii ) discharge rod ( make fibre ) ( xxiii ) thermal imaging camera ( xxiv ) single phase & three phase meter automatic testing bench for 20 positions ( 0.02s class rsm ) frp fencing ( i ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 63 / 100 / 200 / 500 kva substation etc...
31897243 e quotation for seeking firm rates for non schedule items for preparing estimates. gr c repairing of electro mechanical assets and all their associate works like repairing of motors, pumps, starters, panel, cables etc. at rinpas, kanke, ranchi , c / f pump sets , cost towards dismantling of 100 hp wpil make single stage c / f pump and taking out its rotating unit assembly with changing of damaged parts by new making s / f neck ring as per sample size 2 nos, c.i shaft sleeve as per sample size – 2nos, making s / f shaft sleeve check nut as per sample size – 2 nos , s / fball bearing skf 6309 2 nos and repairing of bearinghousing by welding turning machining as per bearing size 2 nos, c.i gland tightner as per sample size – 2nos including cost of reassembling of rotating unit assembly balancing rotating unit assembly and fitting the pump with supply of grease gland packing oil packing paper with transporting cost of rotating unit from p / plant to workshop and back , cost toward supplying fitting & changing of 100 hp jyoti make motor ball bearing skf 6316 at de side 1 no. and sk 6314 nde 1 no. with grease. , cost towards repairing of 100 hp l & t make f.a.s.d starter with s / f contactor set 2 sets ) , relay unit ( 85 135a ) 1set, timer unit 1 set, making new connection etc all complete. , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 100 hp pump set. , cost towards supplying and fitting mccb 630 amp. for bus bar make l&t schneider / bch , cost towards supplying and fitting mccb 250 amp. for bus bar make l&t schneider / bch , cost toward supplying fitting & changing 100mm dia cidf sluice valve ( pn 1 ) 1 set & cidf nr valve ( pn 1 ) 1 no. including fitting charge , cost toward supplying fitting & changing 150 mm dia ci foot valve hiding single leather flat and gun metal seating all complete. , cost towards providing all labours tools & techniciansfor dismantling and disconnecting of 40 hp kirloskar make motor and taken out rotor from motor stator cutting removing burnt and damaged coil and after repairing refitting the same etc all complete. , cost towards full rewinding of 40 hp motor stator with supplying of super enameled round copper conductor suitable gauge class f insulating materials making all connection taping, varnishing with dr beck varnish all complete with deducting the cost of taken out scrap materials ( wt. of wire is 18.5kg approx ) . , s / f ball bearing skf make 6312&6309 at de&nde side of 40 hp kirloskar make motor including proper greasing all complete. , cost towards providing all labour tools and tackles for dismantling of 40 hp single stage kirloskar make c / f pump with changing damaged parts such as gm neck ring as per size and sample 2 nos. shaft sleeve 2 nos. shaft sleeve check nut 2 nos. making ci bearing housing as per size and sample 2 nos. supplying and fitting ball wearing skf make 6309 2nos. making supplying and fitting ms gland tightner as per size and sample 2 pair making citric motion of rotating unit assembling on lathe m / c etc all complete , cost towards repairing of 40 hp l&t motor starter by supplying and fitting l&t make 3 core ml 4 power contactor 45 amp. with auxiliary contractor complete set 2nos. supplying and fitting timer type lt 100 1nos., over load relay suitable range 1nos.etc all complete. , cost towards providing all labours tools & technicians for taking out damaged 250amp. tpn hrc fuse type disconnector main switch replacing new disconnector fuse unit with hrc fuse 1 set doing electrical connection and testing on full load after deducting the cost of taken out scrap materials , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 40 hp pump set. , cost towards providing all labour tools and tackles for dismantling and taken out damaged nr valve and s / f 4”dia c.i df nr valve heavy duty rating pn 1 isi marked on delivery pipe line with all work including cost of labour charge all complete testing on full load with deducting the cost of scrap materials. , cost towards supplying and laying 50 mm² x 3.5 core aluminium armoured cable from main switch to industrial panel. ( both sets ) . , cost towards supplying and laying 16 mm² x 3 core copper cable from panel to starter and starter to motor in bunch of two. ( both sets ) . , cost towards replacing damaged suction pipe by making supply & fitting 100 mm dia heavy duty m.s. suction pipe 10feet long both and 100 mm dia m.s. flange welding, 100mm dia long bend 1 no with nut bolt rubber insertion etc required for the job. , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge. , submersible pump sets , cost towards providing all labour tools and technicians for dismantling and taken out 5hp submersible p / set with column pipe for bore well. , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.2 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , cost towards repairing of5 hp submersible pump with s / f norylimpeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i. suction casing, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards s / f and changing of 2”dia upvc column pipe with heavy duty socket ( make supreme / paras ) for both sets. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. dwsd m1062 , providing all labour, tools tackles& technicians for lowering of 5hp submersible pump set with all accessories in the bore well , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 1 no ( 2 ) 40 mm dia nr valve – 1 no ( 3 ) 40 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape materials. , supplying and installation suitable size panel board for 5 hp submersible pump including fixing on wall comprising of following points such as ( 1 ) d.o.l starter 1no. ( 2 ) hrc fuse – 3 no. ( 3 ) voltmeter with selector switch – 1 set ( 4 ) ammeter with selector switch – 1 set ( 5 ) phase indicating neon lamp – 3 nos. etc. all complete after the deduction of cost of scrap materials. , supplying all material such as 40 mm dia g.i. pipe medium quality 15 ft. long, charcoal salt etc. for making earthing station as per i.e. rule , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , cost towards replacement of old and damaged underground service line by supplying new overhead line 10 mm² 3core copper wire after the deduction of cost of scrap materials. , supplying and laying ( under and over ground ) 2 dia aqua gold weather proof pvc pipe from bore well to main rising pipe line ( damaged pipe replacement ) make supreme / isi mark ( both sets ) , supplying and laying 1.5 dia under and over ground supreme aqua gold / any reputed make weather proof upvc pipe from bore well to dharamshala over head tank. , supplying and fitting union 1.5 dia , supplying and fitting elbow 1.5 dia , supplying and fittingtee 1.5 dia , supplying and fitting socket 1.5 dia , supplying and fitting upvc valve 1.5 dia , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge....
31897240 e quotation for seeking firm rates for non schedule items for preparing estimates. repair and replacement of plumbing fixtures, cleaning of toilet and bathroom of inter ward, icu ward, staff room, female ward, w.w. ward, d.b. ward, duty room, main office building, a. ward, opd, drug store etc. and repairing of submersible pump set, , 10 hp c / f pump set , cost for complete rewinding of 10 h.p sq. cage induction motor operated on 415v, 3 phase, 50 c / s 1460 rpm with supply fitting of super enameled copper wire and other required insulation materials, heating assembly of the motor and testing on load ( wt of burnt coil 5.5 kg ) , cost for dismantling of 10 h.p c / f pump checking and changing of its damaged parts such as pump shaft of en 9 materials 01 no. key 02 nos. gland tightner 2 sets, gland tightner stud 4 nos. c.i bearing housing with cap 2 sets, ball bearing 6306 ( skf ) 2 nos. casing stud 16 mm sq. x 80 mm long with nut 8 nos. packing paper. grease, gland packing etc all complete and testing on load. , cost for supply and fitting of 3 dia tyre coupling complete set with nut, bolt & tyre. all complete. , cost for supply and fitting of 4 dia g.m flap tyre foot valve with packing and nut & bolt 4 nos. etc all complete. , cost for supply and fitting of 3 dia cidf heavy duty sluice valve, isi marked , cost for overhauling and repairing of motor control panel and changing of its damaged parts such as contactor ( ml 4 ) 3 nos., vm 02 nos., am 01, selector switch 2 nos, 100 amp mccb – 1 no, etc all complete and testing on load. , 3 h.p. submersible p / set , providing all labour, tools, tackles and technicians for taking out 3 h.p. submersible pump set with column pipe for bore well , cost towards for rewinding and repairing of 3 h.p submersible motor with s / f suitable winding wire, bronze bush etc. all complete after the deduction of cost of scrape materials. , cost towards repairing of 3 h.p. submersible pump with s / f bronze impeller as per size and sample, bush, thrust plate, pump shaft etc. all complete after the deduction of cost of scrape materials. , cost towards replacement of damaged submersible cable by supplying and fitting 2.5 mm2x 3 core flat submersible cable including cable jointing all complete for both set. jsor cb 1 3 after the deduction of cost of scrape materials. , cost towards supplying fitting, changing 2” dia g.i. column pipe with heavy duty socket ( make zindal / tata ) jsor 9k vi after the deduction of cost of scrape materials. , cost towards supplying and fitting ( 1 ) 2 dia g.m. full way valve – 1 no ( 2 ) 2 dia nr valve – 1 no ( 3 ) 2 dia g.i. bend 2 nos. ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape materials. , providing all labour, tools tackles and technicians for lowering of 3 h.p submersible pump set with all accessories in the bore well , providing all labour, tools tackles and technicians for lowering 3 h.p.submersible pump set with all accessories in the bore well , 5 h.p. / 7.5 h.p. submersible p / set , providing all labour, tools, tackles and technicians for taking out 5 h.p. submersible pump set with column pipe ( 280 ) from bore well , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.0 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , cost towards repairing of 5 hp submersible pump with s / f noryl impeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. , cost towards supplying fitting, changing 2” dia g.i. column pipe with heavy duty socket ( make zindal / tata ) after the deduction of cost of scrape materials. , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 2 no ( 2 ) 50 mm dia nr valve – 1 no ( 3 ) 50 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt – 2 pair after the deduction of cost of scrape materials. , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , providing all labour, tools tackles and technicians for lowering ( 280 ) of 5 h.p.submersible pump set with all accessories in the bore well , supplying and installation suitable size panel board for 5 h.p. submersible pump including fixing on wall comparising of following points such as ( 1 ) d.o.l starter – 1 no. ( 2 ) hrc fuse – 3 no. ( 3 ) volt meter with selector witch 1 set ( 4 ) ammeter with selection switch – 1 set ( 5 ) zindicating neon lamp – 3 no. etc. all complete after the deduction of cost of scrape materials. , supplying of plumber & sweeper for engaged to maintenance of water supply, cleaning of toilet and bathroom, sewer line etc. operating of pump, f.w.v fro interrupted water supply etc. all complete as per direction of e / i. ( including contractor profit ) . period from 01.04.2022 to 31.03.2023 ( i ) ( plumber ) 12 month x 26 days x 1 nos. = 312 nos. , ( ii ) sweeper 12 month x 26 days x 1 nos. = 312 nos. , provision leake repairing of different and size of upvc sch 80 pipe in place of existing / cracked and damaged pipe of isi approved make or equivalent make damaged pipe in trenchage and replacement of pipe and fitting so as to give. i m average cover over the socket of pipes with disposal of excavated earth within initial lead and lift and necessary fitting and earth work in backfilling and cutting pipe to size etc. all complete as per specification and direction of e / i. leakage in 50 mm dia upvc pipe , leakage in 40 mm dia upvc pipe , leakage in 32 mm dia upvc pipe , leakage in 25 mm dia upvc pipe , leakage in 20 mm dia upvc pipe , provision leake repairing of different and size of upvc sch 80 pipe in place of existing / cracked and damaged pipe with red lead and yarn of following nominal bore screwed and socketed joints on wall, ceiling and floor including supplying and fitting on wall hooks or pipe clamp wooden plugs, cutting pipe to size and threading ends where necessary etc. all complete as per specification and direction of e / i. leakage in 50 mm dia upvc pipe , leakage in 40 mm dia upvc pipe , leakage in 32 mm dia upvc pipe , leakage in 25 mm dia upvc pipe , leakage in 20 mm dia upvc pipe , supplying and flaxing u pvc ball valve of approved make all complete as per direction of e / i. 50 mm dia u pvc ball valve , 40 mm dia u pvc ball valve , 32 mm dia u pvc ball valve , 25 mm dia u pvc ball valve , 20 mm dia u pvc ball valve , supplying of material for consumption to day to day works direction of e / i. ( a ) hydrochloric acid ( 500 ml ) , ( b ) bleaching powder ( 25 kg bag ) , ( c ) phenyl liquid ( 1 ltr. ) , ( d ) harpic liquid ( 1 ltr. ) , ( e ) surf ( 1 kg ) , ( f ) nariyal broom , ( g ) pochha broom , ( h ) safi , ( i ) dettol ( 500ml ) , ( j ) phenyl goli ( pkt ) , ( k ) odonil , ( l ) room freshner , ( m ) phooll broom , ( n ) lizol ( 500 ml ) , ( o ) plastic bucket ( 10 l ) , ( p ) plastic mug ( 1 l ) , supplying of materials for c.p. bathroom fitting ( as per schedule rate ) to consumrtion day to day work. 15mm dia c.p. bib cock ( long thread ) , 15mm dia c.p. pillar cock ( long thread ) , 15mm dia c.p. angular stop cock ( long thread ) , 15mm dia cp basin mixture , 15mm dia cp wall mixture , jet sprey , health faucet , bib cock spindle , a ) medium size , b ) large size , mirror , towel rail , soap dish , 32mm dia cp waste : , 32mm dia pvc waste pipe 750mm long with coupling : , 100mm dia c.p. jali : , 15mm dia and 45cm long pvc connection pipe : , sink waste , cistern ball cock , cistern handle , pvc water storage tank cover ( 2000 / 1000 l ) , 25mm dia ball cock set for pvc tank , cammod cover , m seal , waste pipe bundla , 10 lit pvc l / d cistern , flush bend , basin , supplying all materials, labours, tools and equipment for the fitting and fixing cp bathroom fittings in vip fittings including all accessories etc. all complete as per specification and direction of e / i. a ) sink mixture flr5309n jaquar , b ) wall mixture 3 in 1 with wall flange flr5281n jaquar , c ) central hole basin mixture with popup waste system 450mm long braided houses ( con 169knb ) jaquar , d ) pillar cock flr5011n jaquar , e ) bib cock with flange flr – 5053n jaquar , f ) cp bib cock 2 in 1 angular stop cock flr 5041n jaquar , g ) angular stop cock with flange flr 5053n jaquar , h ) health faucet ald 577 jaquar , i ) over head shower with arm ohs 1999 jaquar , j ) glass shelf 22 ( aqn 7771 ) jaquar , k ) towel rail ( akp 35711ps ) jaquar , l ) towel ring ( akp 35721p ) jaquar , m ) soap dish holder akp 35731p jaquar , n ) cp liquid soap dispenser with mettalic bottle acn1137n jaquar , supplying, fitting and fixing pvc pipes of approved make including supplying nails, clips and pvc washer cement & yarn for making plumber joints properly cutting pipe to sizes including earth work of scaffolding etc. where necessary etc. all complete as per specification and direction of e / i. 100mm dia pvc sewer pipe , 75mm dia pvc sewer pipe , supplying and fixing pvc fitting of approved make confirming to isi including supplying nails and bobbins from making solvent cement solution or gasket joints including earth work or providing scaffolding as the case may be all complete as per specification and direction of e / i. 110mm swr nahani trap , 110mm swr plain bend , 110mm swr door bend , 110mm swr plain tee , 110mm swr door tee , 75mm swr plain bend , 75mm swr door bend , 75mm swr plain tee , 75mm swr door tee , providing all material, equipment and wash out and cleaning of 2000 / 1000 litre pvc water storage tank including rubbing the wall of tank by the help of coconut, rushi and bleaching powder their washing by clean water all complete as per direction of e / i. 3000 litre capacity hdpe w / s / tank 2 time x 3000 liter x 2 nos. = 12000.00 liter 2000 litre capacity hdpe w / s / tank 2 time x 2000 liter x 88 nos. = 372000.00 liter 1000 litre capacity hdpe w / s / tank 2 time x 1000 liter x 9 nos. = 18000.00 liter total = 402000.00 liter...
31690848 bids are invited for super enamelled copper winding wire swg 15 , super enamelled copper winding wire swg 16 , super enamelled copper winding wire swg17 , super enamelled copperwinding wire swg 18super enamelled round copper winding wire as per is 13730 total quantity : 450...
31657886 supply of ther200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 21 swg. specn. no. is 13730 part 13 / 1993.ther200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 21 swg. specn. no. is 13730 part 13 / 1993., thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurancee test of 2kv at 50hz size 21 swg. specn. no. is 13730 part 13 / 1993. electric loco shed jharkhand 416.00 kg...
31570209 supply of ther200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. spec. no.is 13730 part 13 / 1993ther200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. spec. no.is 13730 part 13 / 1993, thermax 200 cr type round enameled winding wire grade 2, conveing with additional voltage endurance test of 2kv at 50hz. size 18 swg. spec. no.is 13730 part 13 / 1993 electric loco shed jharkhand 314.00 kg...
31566216 auction sale of disposal of tlac items such as ( 1 ) heating element 5kw for distilled water plant make roxy qty=3nos.=2.4kg ( cu ) ( 2 ) icpn main switch 400amp complete with hrc fuse qty=4nos.=16.92kg ( fe=15kg, cu=1.92kg ) ( 3 ) copper socket 120mm qty=10nos.=0.23kg ( cu ) ( 4 ) ss nut bolt 10x65x30mm qty=6nos.=1.59kg ( fe ) ( 5 ) cover for ddm switch qty=8nos.=39.2kg ( fe ) ( 6 ) relay us type for ll80 switch qty=8nos.=7.52kg ( fe=6.4kg, cu=1.12kg ) ( 7 ) relay ud type for ll80 switch qty=10nos.=0.65kg ( cu ) ( 8 ) relay ur type for d300 switch qty=25nos.=50kg ( fe=45kg, cu=5kg ) ( 9 ) over voltage relay qty=8nos.=12kg ( fe=10.4kg, cu=1.6kg ) ( 10 ) terminal for t 5 qty=2nos.=1.65kg ( fe ) ( 11 ) temperature compensating registance for d 300 qty=29nos.=4.35kg ( fe=2.9kg, cu=1.45kg ) ( 12 ) arm comp. with holder for t 5 dyn qty=2nos.=1.6kg ( fe ) ( 13 ) planger for ddm switch qty=5nos.=8kg ( fe=7kg, cu=1kg ) ( 14 ) scrap parts for change over switch qty=1no.=15.5kg ( fe=15kg, cu=0.5kg ) ( 15 ) old model acos ( scrap ) qty=1nos.=8kg ( fe=7.5kg, cu=0.5kg ) ( 16 ) eyree no.7 flux qty=13nos.=0.52kg ( cu ) ( 17 ) shackle mutatior ( dewell ) qty=5nos.=6.25kg ( fe=5.25kg, cu=1kg ) ( 18 ) ballast chok 300amp qty=3nos.=5.1kg ( fe=3.6kg, cu=1.5kg ) ( 19 ) bunner 5 / 8 wick for haricane lamp qty=9nos.=0.198kg ( fe ) ( 20 ) g9 pipe 1.5 qty=6.200mtrs=19.22kg ( fe ) ( 21 ) float switch complete qty=1no.=0.75kg ( cu ) ( 22 ) heating element 1500w qty=11nos.=4.565kg ( cu ) ( 23 ) single row deep groove ball bearing qty=30nos.=10.8kg ( fe ) ( 24 ) lamp resistance cut in relay 24 32 volt qty=37nos.=3.885kg ( fe ) ( 25 ) battery fuse box qty=6nos.=14.4kg ( fe ) ( 26 ) socket with round trs 3 core cable 3 meters for immersion water heater 1500w 250v qty=6nos.=1.536kg ( cu ) ( 27 ) m.s.bolt+nut4x0.75 qty=2nos.=0.48kg ( fe ) ( 28 ) low voltage transformer qty=3nos.=23.7kg ( fe=16.8kg, cu=6.9kg ) ( 29 ) m.s. rod 10mm fan qty=3.700mtrs=4.07kg ( fe ) ( 30 ) m s bolt & nut 45x6mm qty=2.7kg ( fe ) ( 31 ) foundation bolt 1ftx10 long qty=4nos.=2kg ( fe ) ( 32 ) terminal base complete for 29l dynamo qty=69nos.=4.14kg ( fe ) ( 33 ) s.m. round 42mm qty=45fts.=12.15kg ( fe ) ( 34 ) ictpn main switch 200 amp 415v qty=3nos.=10.35kg ( fe=9.3kg, cu=1.05kg ) ( 35 ) spot long range lamp with halogen bulb qty=3nos.=0.825kg ( fe ) ( 36 ) head light assemble lucus type qty=6nos.=1.8kg ( fe ) ( 37 ) change over switch 32 amp dp qty=1no.=3.9kg ( fe ) ( 38 ) hrc fuse 125amp sin type qty=14nos.=0.63kg ( cu ) ( 39 ) fuse link hrc 315amp qty=6nos.=0.306kg ( cu ) ( 40 ) spring washer 10mmx8mmx1mm qty=200nos.=0.46kg ( fe ) ( 41 ) insulating bush qty=245nos.=2.205kg ( fe ) ( 42 ) duplex nut qty=170nos.=2.55kg ( fe ) ( 43 ) 11 pin precooling socket model cashing qty=1no.=0.056kg ( al ) ( 44 ) solinium lamp ballast rating 60amp 4volt qty=5nos.=7.25kg ( fe=4.5kg, cu=2.75kg ) ( 45 ) s.m round 25mm qty=14.670mtrs.=18.77kg ( fe ) ( 46 ) ll 80 switch complete qty=2nos.=1.6kg ( cu ) ( 47 ) bush carbon for 2d 1159 qty=20nos.=0.7kg ( fe ) ( 48 ) coil ducth for 75dyn qty=4nos.=32kg ( cu ) ( 49 ) coil for d300 qty=53nos.=34.45kg ( fe=5.3kg, cu=29.15kg ) ( 50 ) coil for ll80 switch qty=17nos.=14.45kg ( cu ) ( 51 ) claper for d 300 switch qty=30nos.=7.65kg ( cu ) ( 52 ) clapper for ll80 switch qty=3nos.=0.909kg ( cu ) ( 53 ) claper assemble for d 300 qty=2nos.=3.8kg ( fe=0.8kg, cu=3kg ) ( 54 ) contact for d 300 switch complete qty=7nos.=0.91kg ( cu ) ( 55 ) l contact for d 300 switch qty=157nos.=4.396kg ( al ) ( 56 ) contact for ll 80 switch qty=21nos.=0.735kg ( cu ) ( 57 ) thermo static expansion valve 7.5 tr cap. suitable for r 134a refrigerant for use in bg under qty=18nos.=1.548kg ( fe ) ( 58 ) liquid receiver stainless steel as per icf drg. no. wgscwas 7 3 005 alt f & conforming to icfs qty=1no.=8.54kg ( fe ) ( 59 ) shaft seal assemble smc 4 65 for accel compressor suitable for r 134a used in under slang ac coaches qty=12nos.=2.244kg ( fe ) ( 60 ) burned transformer winding wire qty=30kg ( cu ) ( 61 ) released old cu wire qty=13kg ( cu ) ( 62 ) cap for fuse f.l tube, 20 / 18w qty=10065=30.195kg ( al ) ( 63 ) cap for lamp 110 / 120 v of diff. watt qty=12339=123.39kg ( al ) ( 64 ) release empty box of 6.5 kw rbc qty=30=1890kg ( fe=1890kg ) ( 65 ) release cell connector with nut bolt qty=2148=328.64kg ( fe=223.39kg, al=105.25kg ) ( 66 ) suspension hanger pin qty=169=380.25kg ( fe ) lot no.15 / tl / dhn / 21 / 22, location tlac scrap store / dhn....
31368854 rewinding of 01 no of 85 hp 550 v, 110 mtr head 500 gpm submersible motor with providing winding wire and other internal spare parts of motor of grd project ...
31081439 bids are invited for boqauto extension if any seller submits price in last 15 minutes, the rawill be auto extended by 15 minutes. ( for anunlimited time ) total quantity : 1 1 : copper winding wire, 15 swg 2 : copper winding wire, 17 swg 3 : copper winding wire, 18 swg 4 : copper winding wire, 19 swg 5 : copper winding wire, 19.5 swg 6 : copper winding wire, 20 swg 7 : copper winding wire, 21 swg 8 : copper winding wire, 22 swg 9 : copper winding wire, 23 swg 10 : copper winding wire, 24 swg 11 : copper winding wire, 34 swg 12 description: copper winding wire, 35 swg 13 description: copper winding wire, 36 swg...
30819752 supply of electric line materials , electrical items : , fuse wire 12 swg , fuse wire 14 swg , fuse wire 16 swg , fuse wire 18 swg , fuse wire 22 swg , fuse wire 28 swg , fuse wire 32 swg , all types of connectors , connector pipe to panther , connector panther to panther , connector pipe to ab switch , connector panther to ab switch , connector dog to ab switch , g.i. wire no. 6 , g.i. wire no. 8 , g.i. wire no. 10 for earthing , g.i. wire no. 7 / 16 , earthing g.i strip for ( 65x6 ) , stay set complete ( 1900*20 mm ) with stay wire 7 / 10 swg 8 kg. & guy insulator , stay set complete ( 1800 x16 mm ) with stay wire 7 / 10 swg 8 kgs & guy insulator , lt stay set complete ( 1700 x16 mm ) with stay wire 7 / 12 swg , stay set complete for dss with wire , ms nuts & bolts different size , al. winding wire , earth clamp for earthwire ( 50x6mm ) galvanised , gi earthing pipe 3.1 meter long ( 40mm dia ) , 33 kv angle stay clamp ( 50x6mm ) galvanized , angle / side stay clamp ( 50x6mm ) for 8 mtr 200kg psc pole , ms base plate for 33 kv , anticlimbing device ( barbed wire ) , danger board 33kv , buckle for strap , spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and outgoing 3 phase connection as per field requirement , fabrication item galvanised ( different types of 33kv / 11 kv line ) , note:gst must be define / mentioned otherwise price part not be considered....
30791920 supply of 1 fuse wire 12 swg 2 fuse wire 14 swg 3 fuse wire 16 swg 4 fuse wire 18 swg 5 fuse wire 22 swg 6 fuse wire 28 swg 7 fuse wire 32 swg 8 all types of connectors 9 connector pipe to panther 10 connector panther to panther 11 connector pipe to ab switch 12 connector panther to ab switch 13 connector dog to ab switch 14 g.i. wire no. 6 15 g.i. wire no. 8 16 g.i. wire no. 10 for earthing 17 g.i. wire no. 7/16 18 earthing g.i strip for (65x6) 19 stay set complete (1900*20 mm) with stay wire 7/10 swg 8 kg. & guy insulator 20 stay set complete (1800 x16 mm) with stay wire 7/10 swg 8 kgs & guy insulator 21 lt stay set complete (1700 x16 mm) with stay wire 7/12 swg 22 stay set complete for dss with wire 23 ms nuts & bolts different size 24 al. winding wire 25 earth clamp for earthwire(50x6mm) galvanised 26 gi earthing pipe 3.1 meter long (40mm dia) 27 33 kv angle stay clamp(50x6mm) galvanized 28 angle/side stay clamp(50x6mm) for 8 mtr 200kg psc pole 29 ms base plate for 33 kv 30 anticlimbing device( barbed wire) 31 danger board 33kv 32 buckle for strap 33 spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement 34 fabrication item galvanised (different types of 33kv/11 kv line) ...