East Central Railway - Jharkhand

37828112 supply of battery voltmeter ( uba ) , range:0 150v, specification: clw / es / 3 / 0073 and drg. no. clw / es / 3 / sk 1 / 0073 range 0 150 volts [ warranty period: 30 months after the date of delivery ] ...

Drinking Water And Sanitation Department - Jharkhand

37695394 supply installation testing and commissioning of pump sets, motor control panel, stabilizer and its allied works at bagodih multi village rural water supply scheme at bagodih ( a ) raw water pumping plant 1.01 supplying all labour tools and tackles for taking out old and damaged vt pump sets from intake well with all accessories , demolition of mounting channel for installation of new vertical turbine pump sets. 1.02 supplying, installation, testing and commissioning of electrically driven vertical turbine pump sets kirloskar / wpil / mather & plate / jyoti having discharge capacity of raw water 90 m3 / h against a total head of 75 meter, in all concern coupled with vertical hollow shaft sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) , operated on 415 + 10% volts, 50hz, 1460 rpm ( 10% above the capacity of pump ) with sole plate, discharge head, m.s. d.f. column assembly random length of 5 ft, total 60 ft. s.s. line shaft, s.s, socket, spider bearing with rubber cut less bush, cidf sluive valve 1 no, cidf nr valve 1 no, pressure gauge 1 no ets all complete. 1.03 supplying all labour tools and tackles for making pcc foundation 2′x2′x1′ with all materials such as cement , sand, stone chips, foundation bolt etc all complete including fixing of sole plate for installation of new vt pump sets 1.04 providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated consisting of: proper distribution 200 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 200 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 160 amp tp l&t / siemens / bch / schneider make for outgoing feeder 2 nos ( 1no for each pump sets ) , 32a dp mcb for lighting 1 no., suitable size of fully automatic star delta starter l&t / bch / schnider / havells make 2 nos., ( 1no for each pump sets ) 0 500 v voltmeter with selector switch 1 set, ct operated ampere meter ( 0 120a ) with ct 2 sets, phase indicating neon lamp 6nos, s.p.p. 2nos , doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 1.05 cost towards supplying and laying of 16mm2 x , 3 core pvc insulated and pvc sheathed , 1.1 kv grade unarmored copper cable of reputed make and isi marked doing connection from panel to both motor. jsor dwsd 2021 1.06 cost towards making cable mouth for 16mm2 1.07 cost of doing internal light wiring of pump house with 7 / 18 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 1.08 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 1.09 supplying and laying of 8 swg copper / gi wire for making earthing connection in two from earthing station to panel to motor . 1.10 supplying and fixing 3 ton capacity triple gear chain pulley block with 6 meter lifting chain of reputed make and isi marked. 1.11 supplying 75 kva servo controlled voltage stabilizer suitable for input voltage 280 480 volts, output voltage of 400 volt±1%, 3 ph, 50 hz, with copper wound transformer ( oil cooled ) , unbalanced type, air cooled / oil cooled, three phase, frequency : 50 hz. speed of correction : 35v / second. regulation : + 1% from no load to full load.ambient temperature : 0 to 55 degree centigrade ( designed for indoor / outdoor continuous operation. operation : automatic cum manual, mcb for short circuit & over load protection, high volt low volt indicator & volt meter with all necessary switches and indicator the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box with bidirectional wheels for easy handling, necessary monitors and user’s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, auto / manual selector switch, raise / low push button etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. all three phases shall independently monitored and corrected. make – powerline / servokon 1.12 supplying and fitting 200 amp changeover switch. make – havell’s / hpl 1.13 supplying and filling transformer oil. 1.14 supplying and laying 120 sq. mm x 3.5 core pvc sheathed & pvc insulated, 1.1 kv grade aluminum unarmoured cable. make – polycab / kei / universal / isi 1.15 cost for supplying and laying delivery pipe line with s / f of 4dia heavy duty gi pipe 5, flange 5nos., rubber insertion 5kg, nut bolt 8kg, with cutting of pipe in required size and welding with all labour tools and tackles. ( b ) clear water pumping plant 1.16 supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundation for installation of new hsc centrifugal pump sets. 1.18 supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & plate / jyoti ) having discharge capacity of clear water 90 m3 / h against total head of 30 meter coupled with tefc sq. cage induction motor make ( kriloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 set etc all complete. 1.19 supplying all labour tools and tackles for making pcc foundtiaon 1nos, of size 6′x3x3′ with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface. 1.20 cost for supply and laying of suction pipe line with s / f of 6 dia heavy duty g.i. pipe 6m, bend 2 nos., flange 6 nos., nut, bolt, washer 10kg, rubber insertion etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) 1.21 providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – proper distribution 100 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 100 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 63 amp tp l&t / siemens make for outgoing feeder 2 nos. ( 1no for each pump sets ) suitable size of fully automatic star delta starter l & t / bch / schnider make 2 nos. 0 500 v voltmeter with selector switch 2nos ct operated ampere meter 0 100a ) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 1.22 cost towards supplying and laying of 10 mm2 , 3 core pvc insulated and pvc sheathed, 1.1 kv grade unarmered copper cable of reputed make and isi marked for doing connection from panel to motor. jsor dwsd 2021 1.23 cost towards making cable mouth for 10mm2 1.24 cost of doing internal light wiring of pump house with 7 / 18 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 1.25 cost for doing chemical earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 1.26 supplying and laying of 8 swg copper / gi wire for making earthing connection in to from earthing station to panel to motor . 1.27 cost for supplying and laying delivery pipe line with s / f of 4dia heavy duty gi pipe 5, flange 5nos., rubber insertion 5kg, nut bolt 8kg, with cutting of pipe in required size and welding with all labour tools and tackles. 2 supply, installation, testing and commissioning of 1no v.t. pump set at raw water pumping plant and 1 no h.s.c. pump set at clear water pumping plant and its allied works at rural water supply scheme, dumri ( a ) raw water pumping plant, dumri 2.01 supplying all labour tools and tackles for taking out old and damaged vt pump sets from intake well with all accessories , demolition of mounting channel for installation of new vertical turbine pump sets. 2.02 cost towards supplying, installation and commissioning of vertical turbine water lubricated single / multi stage pump set of kirlosker / jyoti / mather & platt / wpil make capable of discharge 36.55 lps against total head 36 m, with suitable discharge head base plate and accessories such as m.s. column pipe of suitable dia, flange type 40ft ( 5ft length 7nos and 2.5ft 2nos ) , line shaft , spider bearing with rubber cutless bush for 40ft column assembly, coupled with suitable capacity vertical hollow shaft squirrel cage tefc induction motor of kirlosker / jyoti / cgl / abb / bhel make , operated on 415±10% volt , 3 phase, 50 c / s, a.c. supply having 1450 rpm , with non reversible rachet, including cost of supplying fitting and fixing of all required accessories such as strainer, sluice valve, n.r. valve, pressure gauge etc all complete. 2.03 cost for supply and fitting of ml3 starter of l&t make. 2.04 cost for breaking of old pcc foundation and making new pcc foundation size ( 600mm x 600mm x 400mm ) with supply and fitting of 5 / 8 inch dia x 300mm long foundation bolt 4nos, stone chips, sand, cement etc and plastering and punning of exposed surface etc all complete 2.05 cost for supplying and laying of 3core 10 sq. mm, copper cable unarmoured, p.v.c insulated and p.v.c. sheathed 1100 v grade with isi mark from motor to starter in 2 length each for both motor. 2.06 cost for doing socketing of 3 core 10 sqmm cable, with supplyu and fiotting of copper lugs with all required insulating materials. 2.07 supplying 50 kva servo controlled voltage stabilizer suitable for input voltage 280 480 volts, output voltage of 400 volt±1%, 3 ph, 50 hz, with copper wound transformer ( oil cooled ) , unbalanced type, oil cooled, three phase, frequency : 50 hz. speed of correction : 35v / second. regulation : + 1% from no load to full load.ambient temperature : 0 to 55 degree centigrade ( designed for indoor / outdoor continuous operation. operation : automatic cum manual, mcb for short circuit & over load protection, high volt low volt indicator & volt meter with all necessary switches and indicator the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box with bidirectional wheels for easy handling, necessary monitors and user’s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, auto / manual selector switch, raise / low push button etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. all three phases shall independently monitored and corrected. make – powerline / servokon 2.08 supplying and fitting 200 amp changeover switch. make – havell’s / hpl 2.09 supplying and filling transformer oil. 2.10 supplying and laying 70 sq. mm x 3.5 core pvc sheathed & pvc insulated, 1.1 kv grade aluminium unarmoured cable. make – polycab / kei / universal / isi 2.11 cost of doing internal light wiring of pump house with 7 / 20 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 2.12 supplyng and fitting of 150 mm dia cidf sluice valve with nut bolts washer insersation rubber with all labour tool, tackles and technician charges etc. all complete job ( b ) clear water pumping plant, dumri 2.13 cost towards supplying of hsc c / f pump capable for discharging 36 lps against total head 45 m ( make: kirloskar / crompton greese / jyoti / mather & platt / wpil ) coupled with sutibale size of squirell cage 3 phase induction motor ( make: kirloskar / crompton greaves / jyoti / abb / bhel ) operated on 415v, 50c / s, 1450rpm fitted on common channel fabricated base plate with required size of heavy duty , sluice valve 1no., n.r. valve 1no, pressure guage 1no., etc all complete. 2.14 cost towards dismantling of old 25hp c / f pump motor from base plate by gas cutter, cost for breaking of old existing foundation and removing of all garbage from pump house with all labour tools, tackles and technician cost. making new pcc foundation for above centrifugal pump set of casting of new pcc foundation of size 5 x 3 x 3 deep with s / f of 5 / 8 x 3 long foundation bolt 6nos, cement, sand, stone chips and plastering and punning of exposed surface etc all complete. 2.15 cost for supplying and laying of 3core 10 sq. mm, copper cable unarmoured, p.v.c insulated and p.v.c. sheathed 1100 v grade with isi mark from motor to starter in 2 length each for both motor. 2.16 cost for making and fitting of 6 dia common header with s / f of 6dia heavy duty gi pipe 6mtr, 6dia bend 2nos, 6 dia flange 10nos, rubber insertion 15kg. nut+bolt+washer 16kg, cutting of pipe in require length and duing complete welding etc all complete with all labour tools and tackles. 2.17 cost towards consumable materials such as grease, gland packing, insertion rubber, nut bolt, jute, logbook, , led bulb, broom etc. 2.18 cost for doing socketing of 3 core 10 sqmm cable, with supplyu and fiotting of copper lugs with all required insulating materials. 2.19 supplying 50 kva servo controlled voltage stabilizer suitable for input voltage 280 480 volts, output voltage of 400 volt±1%, 3 ph, 50 hz, with copper wound transformer ( oil cooled ) , unbalanced type, air cooled / oil cooled, three phase, frequency : 50 hz. speed of correction : 35v / second. regulation : + 1% from no load to full load.ambient temperature : 0 to 55 degree centigrade ( designed for indoor / outdoor continuous operation. operation : automatic cum manual, mcb for short circuit & over load protection, high volt low volt indicator & volt meter with all necessary switches and indicator the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box with bidirectional wheels for easy handling, necessary monitors and user’s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, auto / manual selector switch, raise / low push button etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. all three phases shall independently monitored and corrected. make – powerline / servokon 2.20 supplying and fitting 200 amp changeover switch. make – havell’s / hpl 2.21 supplying and filling transformer oil. 2.22 supplying and laying 70 sq. mm x 3.5 core pvc sheathed & pvc insulated, 1.1 kv grade aluminium unarmoured cable. make – polycab / kei / universal / isi 2.23 cost of doing internal light wiring of pump house with 7 / 20 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 2.24 supplyng and fitting of 300 mm dia cidf sluice valve with nut bolts washer insersation rubber with all labour tool, tackles and technician charges etc. all complete job 2.25 cost towards supplying of hsc c / f pump capable for discharging 36 lps against total head 45 m ( make: kirloskar / crompton greese / jyoti / mather & platt / wpil ) coupled with sutibale size of squirell cage 3 phase induction motor ( make: kirloskar / crompton greaves / jyoti / abb / bhel ) operated on 415v, 50c / s, 1450rpm fitted on common channel fabricated base plate with required size of heavy duty , sluice valve 1no., n.r. valve 1no, pressure guage 1no., etc all complete. 3 supply installation testing and commissioning of pump sets, motor control panel, stabilizer and its allied works at bharkatta multi village rural water supply scheme at bharkatta ( a ) raw water pumping plant: 3.01 supplying all labour tools and tackles for taking out old and damaged vt pump sets from intake well with all accessories , demolition of mounting channel for installation of new vertical turbine pump sets. 3.02 supplying, installation, testing and commissioning of electrically driven water lubricated vertical turbine pump sets kirloskar / wpil / mather & plate / jyoti having discharge capacity of raw water 114 m3 / h against a total head of 39 meter, in all concern coupled with vertical hollow shaft sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) , operated on 415 + 10% volts, 50hz, 1460 rpm ( 10% above the capacity of pump ) with sole plate, discharge head, m.s. d.f. column assembly random length of 5 ft, total 45 ft. s.s. line shaft, s.s, socket, spider bearing with rubber cut less bush, cidf sluice valve 1 no, cidf nr valve 1 no, pressure gauge 1 no ets all complete. 3.03 supplying all labour tools and tackles for braking old pcc and making new pcc foundation 2′x2′x1′ with all materials such as cement , sand, stone chips, foundation bolt etc all complete including fixing of sole plate for installation of new vt pump sets 3.04 providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated consisting of: proper distribution 200 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 200 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 100 amp tp l&t / siemens / bch / schneider make for outgoing feeder 2 nos ( 1no for each pump sets ) , 32a dp mcb for lighting 1 no. suitable size of fully automatic star delta starter l&t / bch / schnider / havells make 2nos. ( 1no for each pump sets ) 0 500 v voltmeter with selector switch 1 set ct operated ampere meter ( 0 120a ) with ct 2 sets, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 3.05 cost towards supplying and laying of 16mm2 x , 3 core pvc insulated and pvc sheathed , 1.1 kv grade unarmored copper cable of reputed make and isi marked doing connection from panel to both motor. jsor dwsd 2021 3.06 cost towards making cable mouth for 16mm2 3.07 cost of doing internal light wiring of pump house with 7 / 18 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 3.08 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 3.09 supplying and laying of 8 swg copper / gi wire for making earthing connection in two from earthing station to panel to motor . 3.10 supplying and fixing 3 ton capacity triple gear chain pulley block with 6 meter lifting chain of reputed make and isi marked. 3.11 supplying 50 kva servo controlled voltage stabilizer suitable for input voltage 240 480 volts, output voltage of 400 volt±1%, 3 ph, 50 hz, with copper wound transformer ( oil cooled ) , unbalanced type, oil cooled, three phase, frequency : 50 hz. speed of correction : 35v / second. regulation : + 1% from no load to full load.ambient temperature : 0 to 55 degree centigrade ( designed for indoor / outdoor continuous operation. operation : automatic cum manual, mcb for short circuit & over load protection, high volt low volt indicator & volt meter with all necessary switches and indicator the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box with bidirectional wheels for easy handling, necessary monitors and user’s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and output voltage, auto / manual selector switch, raise / low push button etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. all three phases shall independently monitored and corrected. make – powerline / servokon. 3.12 supplying and laying 50 sq. mm x 3.5 core pvc sheathed & pvc insulated, 1.1 kv grade aluminium unarmoured cable. make – polycab / kei / universal / isi 3.13 supplying and fitting 200 amp changeover switch. make – havell’s / hpl 3.14 supplying and filling transformer oil. 3.15 cost for supplying and laying delivery pipe line with s / f of 4dia heavy duty gi pipe 5, flange 5nos., rubber insertion 5kg, nut bolt 8kg, with cutting of pipe in required size and welding with all labour tools and tackles. 3.16 cost towards supplying and laying of 16mm2 x , 3 core pvc insulated and pvc sheathed , 1.1 kv grade unarmored copper cable of reputed make and isi marked doing connection from panel to both motor. jsor dwsd 2021 ( b ) clear water pumping plant: 3.17 supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundation for installation of new hsc centrifugal pump sets. 3.18 supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & plate / jyoti ) having discharge capacity of clear water 114 m3 / h against total head of 37 meter coupled with tefc sq. cage induction motor make ( kriloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 set etc all complete. 3.19 supplying all labour tools and tackles forbreaking old pcc and making new pcc foundtiaon 1nos, of size 6′x3x3′ with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface. 3.20 cost for supply and laying of suction pipe line with s / f of 6 or suitable dia heavy duty g.i. pipe 6m, bend 2 nos., flange 6 nos., nut, bolt, washer 10kg, rubber insertion etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) 3.21 providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated consisting of: proper distribution 200 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 200 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 100 amp tp l&t / siemens / bch / schneider make for outgoing feeder 2 nos ( 1no for each pump sets ) , 32a dp mcb for lighting 1 no. suitable size of fully automatic star delta starter l&t / bch / schnider / havells make 2 nos. ( 1no for each pump sets ) 0 500 v voltmeter with selector switch 1 set ct operated ampere meter ( 0 120a ) with ct 2 sets, phase indicating neon lamp 6nos s.p.p. 2nos doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 3.22 cost towards supplying and laying of 10 mm2 , 3 core pvc insulated and pvc sheathed, 1.1 kv grade unarmered copper cable of reputed make and isi marked for doing connection from panel to motor. jsor dwsd 2021 3.23 cost towards making cable mouth for 10mm2 3.24 cost of doing internal light wiring of pump house with 7 / 20 single core copper wire will all required making short point 1 no, medium point 4 nos, long point 1 no with supplying and fixing 4′x40 watt tube light 3 nos, 25 watt, led flood light with bracket 1 no etc all complete. 3.25 cost for doing chemical earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 3.26 supplying and laying of 8 swg copper / gi wire for making earthing connection in to from earthing station to panel to motor . 3.27 cost for supplying and laying delivery pipe line with s / f of 4dia heavy duty gi pipe 3, flange 5nos., rubber insertion 5kg, nut bolt 8kg, t 01 no. with cutting of pipe in required size and welding with all labour tools and tackles. 3.28 supplying and fitting 200 amp changeover switch. make – havell’s / hpl...

Bharat Coking Coal Limited - Jharkhand

37603178 bids are invited for item1 , item2 , item3 , item4 , item5 , item6 , timer 0.5 10s 22 ovdc ampere meter 400 200 5a voltmeter anl g 0 600 4in thermometer oil temp msrng assembly contactor tc pwr 415v 3p 220v 500a sling web 4m 10ton polyster total quantity : 50...

Drinking Water And Sanitation Department - Jharkhand

37406346 e quotation for seeking firm rates for non schedule items for preparing estimates of annual repair and maintenance of water supply system and sanitation t rinpas, kanke, ranchi under d.w and s mechanical division, ranchi. , cost towards providing all labours tools & techniciansfor dismantling and disconnecting of 40 hp kirloskar make motor and taken out rotor from motor stator cutting removing burnt and damaged coil and after repairing refitting the same etc all complete. , cost towards full rewinding of 40 hp motor stator with supplying of super enameled round copper conductor suitable gauge class f insulating materials making all connection taping, varnishing with dr beck varnish all complete with deducting the cost of taken out scrap materials ( wt. of wire is 18.5kg approx ) . , s / f ball bearing skf make 6312&6309 at de&nde side of 40 hp kirloskar make motor including proper greasing all complete. , cost towards providing all labour tools and tackles for dismantling of 40 hp single stage kirloskar make c / f pump with changing damaged parts such as gm neck ring as per size and sample 2 nos. shaft sleeve 2 nos. shaft sleeve check nut 2 nos. making ci bearing housing as per size and sample 2 nos. supplying and fitting ball wearing skf make 6309 2nos. making supplying and fitting ms gland tightner as per size and sample 2 pair making citric motion of rotating unit assembling on lathe m / c etc all complete , cost towards repairing of 40 hp l&t motor starter by supplying and fitting l&t make 3 core ml 4 power contactor 45 amp. with auxiliary contractor complete set 2nos. supplying and fitting timer type lt 100 1nos., over load relay suitable range 1nos.etc all complete. , cost towards providing all labours tools & technicians for taking out damaged 250amp. tpn hrc fuse type disconnector main switch replacing new disconnector fuse unit with hrc fuse 1 set doing electrical connection and testing on full load after deducting the cost of taken out scrap materials , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 40 hp pump set. , cost towards providing all labour tools and tackles for dismantling and taken out damaged nr valve and s / f 4”dia c.i df nr valve heavy duty rating pn 1 isi marked on delivery pipe line with all work including cost of labour charge all complete testing on full load with deducting the cost of scrap materials. , cost towards supplying and laying 50 mm² x 3.5 core aluminium armoured cable from main switch to industrial panel. ( both sets ) . , cost towards supplying and laying 16 mm² x 3 core copper cable from panel to starter and starter to motor in bunch of two. ( both sets ) . , cost towards replacing damaged suction pipe by making supply & fitting 100 mm dia heavy duty m.s. suction pipe 10feet long both and 100 mm dia m.s. flange welding, 100mm dia long bend 1 no with nut bolt rubber insertion etc required for the job. , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge. , cost towards dismantling of 100 hp wpil make single stage c / f pump and taking out its rotating unit assembly with changing of damaged parts by new making s / f neck ring as per sample size 2 nos, c.i shaft sleeve as per sample size – 2nos, making s / f shaft sleeve check nut as per sample size – 2 nos , s / fball bearing skf 6309 2 nos and repairing of bearinghousing by welding turning machining as per bearing size 2 nos, c.i gland tightner as per sample size – 2nos including cost of reassembling of rotating unit assembly balancing rotating unit assembly and fitting the pump with supply of grease gland packing oil packing paper with transporting cost of rotating unit from p / plant to workshop and back , cost toward supplying fitting & changing of 100 hp jyoti make motor ball bearing skf 6316 at de side 1 no. and sk 6314 nde 1 no. with grease. , cost towards repairing of 100 hp l & t make f.a.s.d starter with s / f contactor set 2 sets ) , relay unit ( 85 135a ) 1set, timer unit 1 set, making new connection etc all complete. , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 100 hp pump set. , cost towards supplying and fitting mccb 630 amp. for bus bar make l&t schneider / bch , cost towards supplying and fitting mccb 250 amp. for bus bar make l&t schneider / bch , cost toward supplying fitting & changing 100mm dia cidf sluice valve ( pn 1 ) 1 set & cidf nr valve ( pn 1 ) 1 no. including fitting charge , cost toward supplying fitting & changing 150 mm dia ci foot valve hiding single leather flat and gun metal seating all complete. , submersible pump sets , cost towards providing all labour tools and technicians for dismantling and taken out 5hp submersible p / set with column pipe for bore well. , cost towards repairing of5 hp submersible pump with s / f norylimpeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i. suction casing, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.2 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , supplying all material such as 40 mm dia g.i. pipe medium quality 15 ft. long, charcoal salt etc. for making earthing station as per i.e. rule , cost towards replacement of old and damaged underground service line by supplying new overhead line 10 mm² 3core copper wire after the deduction of cost of scrap materials. , supplying and laying ( under and over ground ) 2 dia aqua gold weather proof pvc pipe from bore well to main rising pipe line ( damaged pipe replacement ) make supreme / isi mark ( both sets ) , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , cost towards s / f and changing of 2”dia upvc column pipe with heavy duty socket ( make supreme / paras ) for both sets. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. , providing all labour, tools tackles& technicians for lowering of 5hp submersible pump set with all accessories in the bore well , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 1 no ( 2 ) 40 mm dia nr valve – 1 no ( 3 ) 40 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape , supplying and installation suitable size panel board for 5 hp submersible pump including fixing on wall comprising of following points such as ( 1 ) d.o.l starter 1no. ( 2 ) hrc fuse – 3 no. ( 3 ) voltmeter with selector switch – 1 set ( 4 ) ammeter with selector switch – 1 set ( 5 ) phase indicating neon lamp – 3 nos. etc. all complete after the deduction of cost of scrap materials. , supplying and fitting union 1.5 dia , supplying and fitting elbow 1.5 dia , supplying and fittingtee 1.5 dia , supplying and fitting socket 1.5 dia , supplying and fitting upvc valve 1.5 dia , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge....

Department Of Heavy Industry - Jharkhand

37373700 bids are invited for 3x800 mw pvunl patratu tpp tachometer , tongtester dc 4000a , ammeter tong tester , voltmeter , fault locator cable test kit , relay test kit , tan delta test kit , bdv tester for oil , noise level meter , ductor for transformer winding r , dead weight test accuracy class min 0.05 percent , electro pneumatic calibrator accuracy 0.1 percent of full scale , fluidised temp bath 100 600 deg. c, stability plus minus 0.2 percent deg. c , hygrometer , portable voltmeter calibrator , resistance thermometer bridge 0 2000, resolution 0.001, accuracy plus minus 0.005, sensitivity 0.001 percent, amb. temp. 50 deg. c plus minus 0.005 percent of span per 1 deg. c , test reference rtd , digital storage oscilloscope , portable tc thermo couple rtd calibrator simulator open tender enquiry for fqa lab electrical for total quantity : 21...

Jharkhand State Electricity Board - Jharkhand

37000996 annual maintenance work including periodic and preventive maintenance of equipments and testing of grid equipments as per standard operating procedure at 220 / 132 kv grid sub station ramchandrapur ( adp 2 ) for f.y. 2023 24 from 16.05.2023 to 31.03.2024 1 checking & observation (1. clamp, connectors & jumpers/2.air & gas pressure/3.batterries & battery system/4. control & relay panels 5. transformers oil & winding temp, fans, oil level, silica gel etc. 6. oil leakage & equipment noise). highly skilled 1 person, skilled 1 person & unskilled 2 persons. 2 preventive/routine maintenance of grid substation as per schedule provided by engineer incharge a 220 kv bay/132 kv bay nut bolt tightening, adjustment of contacts (male/female) cleaning, greasing, mobilization, & jelly putting in clamp & connectors ,earthing flat, jumpers and other equipments related with insulators, isolators, ct,pt, cb, la, dropping, and panel of a bay b 132 kv half main bus nut bolt tightening, adjustment, cleaning, greasing, mobilization, & jelly putting in clamp & connectors, earthing flat, jumpers and other equipments related with insulators, isolators, pt. c 132 kv transfer bus nut bolt tightening, adjustment, cleaning, greasing, mobilization, & jelly putting in clamp & connectors, earthing flat, jumpers and other equipments related with insulators, isolators, pt. d 220 kv half main bus i&ii ,nut bolt tightening, adjustment, cleaning, greasing, mobilization, & jelly putting in clamp & connectors, earthing flat, jumpers and other equipments related with insulators, isolators, pt. e 220 kv transfer bus nut bolt tightening, adjustment, cleaning, greasing, mobilization, & jelly putting in clamp & connectors, earthing flat, jumpers and other equipments related with insulators, isolators, pt. f transformer nut bolt tightening,cleaning, in clamp & connectors, earthing flat, jumpers, silica gel filling, and other equipments related with transformer body. g sst nut bolt tightening,adjustment, cleaning, clamp & connectors ,earthing flat, jumpers and other equipments related with sst body. h transformer ir value measurement, i transformer bdv measurement, j circuit breaker ir value measurement, k ct[of a bay] ir value measurement, (quarterly basis) l ct ratio test quarterly, knee point, secondary resistance & tanδ & capacitance yearly basis. m la [of a bay] ir value measurement (yearly basis) n pt /cvt[set] ir value measurement (yearly basis) o pt/cvt tanδ & capacitance yearly basis (yearly basis) p measurement & testing of transmision line using fault locator or any other device q measurement & testing of cb and relay using ct injection kit or any other device ( timing test and tanδ & capacitance yearly basis and crm half yearly basis). r measurement & testing of any grid equipment using any kit available in jusnl or grid s thermography vision report of all grid equiopments. 3 maintenance/emergency maintenance of grid substation as per schedule and job provided by engineer incharge a replacement of nut bolts b replacement of jumper (conductor/ strip) c replacement of clamp & connectors/pg/jumper conia d replacement of female contact e replacement of female contact base f replacement of isolator blade g replacement of isolator blade base h replacement of female contact at high level i replacement of isolator blade at high level j replacement of insulators k replacement of 220 kv or 132kv ct/pt junction box including cable terminationn& connection l replacement of 132kv cb pole m replacement of 220 kv cb pole n minor repairing of trasformer meggering with opening of bushing connectors , checking of prv, vent pipe & buchholz relay, oil top up etc….. including all or any. o minor repairing of ct meggering,opening top cover, replacement of gasket & ct stud , oil topup etc..including all or any p minor repairing of pt meggering,opening top cover, replacement of gasket & pt stud , oil top up etc..including all or any q minor repairing of cb meggering,gas filling, checking of mcb, contactors, motor, spring and tripping or closing coils, sf6 gas filling etc… including all or any. r minor repairing of isolator adjustment of contacts & moving part etc… s minor repairing of panel looping & wiring of cabels, loose contact rectification, replacement of lugs,ferrules etc… t filling of sf6 gas u fixing and replacement of earthing copper bond/flat v fixing and replacement of energy meter/ mw meter/ voltmeter/ ammeter/ relay 4 misc work of grid substation as per schedule and job provided by engineer incharge a battery system cleaning b cleaning of panels( including all 132kv panel, 220 kv panel ,acdb, dcdb,etc) c rectification of lighting and auxiliary power supply in grid premises & colony d material/ equipment manual shifting & movement in grid premises e measurement of earth footing resistance of all earth pits. f laying of control cable 5 break down maintenance a mobilization/demobilization of labour gang b supply of emergency gang with t&p for work like conductor snapping of main bus 6 supply of hydra / crane(upto 8mt capacity ) as per requirement 7 complete overhauling with painting of 150 mva transformer cooling fans with supply of all materials if required 8 transportation of materilas & equipments through truck/pickup upto 3mt including loading,unloading of the materials (i)upto first 50km (ii)50km

Drinking Water And Sanitation Department - Jharkhand

36990274 for supplying, installation, testing and commissioning of 2 set of new 175 hp vt pump sets, motor control panel and its allied work at raw water pumping plant , multi panchayat rural water supply scheme madhuban pirtand , v.t. pump set: , supplying, installation, testing and commissioning of water lubricated vertical turbine pump [ make: kirloskar / mather & platt / jyoti / wpil ] capable of discharging 45 lps raw water against a total head of 185 meter at speed not more than 1500 rpm as per is: 1710 / 1989 with column length not less than 50 ft in 5ft eachwith closed type ss impeller, ss line shaft, ss shaft sleeves, flanged type ms column pipes suitable for below the floor installation and existing delivery header coupled with verticalhollow shaft operated on 415v±10%, 3 phase, ac, 50±5%hz, 4 pole, duty s1, insulation f, lt squirrel cage induction motor with suitable size of coupling as per latest is specification [ make: abb / bhel / crompton / marathon / jyoti / kirloskar ] having 10% more bhp than the pump, making alignment, making electrical connections, with all required tools, tackles, consumables as required, testing and commissioning on full load as per the direction of e / i. etc all complete. , cost towards dismantling, lifting of old 175 hp pump sets with all 200 mm dia column pipes from intake well and loweringnew pump sets with all accessories along with all labour tools and tackles etc all complete. , cost towards breaking of old pcc foundation and removing of all garbage from pump house to out side with lead of 300 m with all labour tools and tackles etc all complete. , cost towards making of newpccfoundation sizing 3 x 3 x 1 with supplying and fitting of foundation bolt 4nos., cement, sand , stone chips, as required and plastering and punnning over exposed surface etc with materials, all labour tools and tackles etc all complete. , cost towards supply and laying of 3c x 95 sq. mm copper cable, pvc insulated & pvc sheathed, 1100v grade, isi marked, make.havells / polycab / finolex / gemscab / any reputed make for 3 pump sets , socketing of terminal ends with s / f of terminal socket including all labour , tools and tackles. 3 core x 95mm2, copper cable 12 ends. , cost towards supplying and fixing 5 ton capacity, triple spur gear type chain pulley block suitable for capacity as below with 6 meter lift complete with load chain and hand chain suitable for above lift , tested to 50% over load as per is 3832 carryingisi mark with travelling trolley etc. , providing floor mounted cubical l.tmotor control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – ( a ) incoming: ( i ) proper distribution 800 amp copper bus bar 4 pole 1 set ( ii ) mccb 800 amp. acb, make l&t / siemens for incoming feeder 1no. ( iii ) 0 500 v voltmeter 1no. with selector switch 1 no, ct operated ampere meter ( 0 500a ) 1no. selector switch 1 no, phase indicating neon lamp 3 nos. ( b ) outgoing: ( i ) mccb 630 amp. tpn type, make l&t / siemens for outgoing feeder 3 nos. ( 01 no for each pump set ) ( ii ) suitable size of fasd starter l&t / bch / schneider make 3 nos. ( iii ) 0 500 v voltmeter 3nos. with selector switch 3 nos, ct operated ampere meter ( 0 500a ) 3nos. selector switch 3 nos, phase indicating neon lamp 9 nos, single phase preventor 3 nos., doing internal wiring with proper gauge of copper wire etc all complete job with testing on full load....

Drinking Water And Sanitation Department - Jharkhand

36990263 renovation with supply installation testing and commissioning of pump set, overhauling of motor control panel and its allied work at rural water supply scheme, chirkunda kumardhubi, maithan ( old scheme ) , raw water pumping plant: , cost towards supplying, installation, testing and commissioning of electrically drivenhorizontal split casing centrifugalpump set make ( kirloskar / wpil / mather & plate / jyoti ) coupled with tefc sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with suitable size of cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 no etc all complete.head 50 mdischarge 275 m3 / h ( hp 100 approx ) , supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundationfor installation of new hsc centrifugal pump sets. , supplying all labour tools and tackles for making new pcc foundtiaon of size 6 x 3 x 3 with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface with all labour, tools, tackle and technician charges. , cost towards supply and laying of suction pipe line with s / f of 10 dia g.i. pipe 2 meter, 10 dia g.i. bend 1 no., 10dia g.i. flange 4nos., rubber insertion 10kg, nut, bolt & washer 10kg etc and cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) , cost towards supply and laying of 8dia delivery line with s / f of8 dia heavy duty g.i. pipe 1 meter, 8dia g.i. flange 4nos., rubber insertion 10kg, nut, bolt & washer 10kg etc and cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) , cost towards overhauling of motor control panelwith all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wireconnection inside panel. cleaning, checking, rectifying of faults with supply and fitting of damaged spares such as bus bar 1set, ampere meter 1no., voltmeter 1no., indicating lamps 3 no. etc, dressingof motor cables with new lugs, crimping works etc all complete and testing on full load. ( rate after deducting the cost of scrap materials ) . , cost towards overhauling of f.a.s.d. starter panelwith all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wireconnection inside panel. cleaning, checking, rectifying of faults with supply and fitting of contacter set ( ml 4 1no and ml 6 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work, dressingand doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . , cost towards supplying and fitting of 30w led flood light, with bracket, copper wire, on off switch etc with all accessories including all labour tools , tackles and technician charges., with cp & ohc, ( rate after deducting the scrap materials. ) . make havells / syska / mescab / polycab / phillips , providing chipping work on the roof surface of raw water pump house, removing of all garbage to outside with lead of 50 m , providing and cleaning of concrete surface to remove dust and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. on identification of seepage, cement grouting to be done with non shrink expanding admixture of sika lndia pvt.ltd. / myk schomberg / dr fixit / fosroc or equivalent. [ size 12.5 m x 6.7 m = 83.75 m2 ] , cost towards providing pcc m 200 in nominal mix of 1:1.5:3on roof with approved quality of stone chips 12mm to 6mm size graded andclean course sand of fm 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of e / i. [ jsor bcd 2018 5.3.2.1 ] [ size 12.5 m x 6.7 m x 0.05 m= 4.19 m3 ] , providing 12 mm thick water proof cement plaster ( 1:3 ) with clean coarse sand of f m. 1.5 with integral water proofing compound liquid @125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i.brand fosroc conplast x421 lc, sika plastocrate plus, dr fixit pidiproof lw+, myk proof wp 10 or equivalent. [ size 12.5 m x 6.7 m = 83.75 m2 ] , dismantling old plaster and pointing in cement or lime and taking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of e / i. inside and outside of pump house, approx=310 m2 , providing 6mm thick cement plaster ( 1:4 ) in ceiling and wall of building with clean coarse sand of f.m. 15 including screening, curingwith all leads and liftsof water, scaffoldingtaxes and royalty all complete as per buildingspecification and direction of e / i. , providing two coats ofsnowcemofapproved shade and make overold surfaceincluding washing cleaning and preparing the walls , scaffolding, curing and taxes all completeas per building specification and direction of e / i. , providing 2 ( two ) coats of synthetic enamel paint of approved shade & make oversteel surface including cleaning the surface, removing dirt, scales, smokes, grease, scaffolding & taxes all complete as per building specification and direction of e / i. for door, window, common header pipe, valves etc. approx 30m2 , clear water pumping plant: , cost towards supplying and fitting of complete rotating assembly for 50hp centrifugal pump, having head 65m discharge 113.5 m3 / hr make kirloskar with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) , cost towards supplying and fitting of complete rotating assembly for 50hp centrifugal pump, having head 70 m discharge 114 m3 / hr make wpil with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) , cost towards supplying and fitting of complete rotating assembly for 60hp centrifugal pump, having head 70 m discharge 160 m3 / hr make mather & platt with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) , cost towards supply and fitting of 4dia coupling set for 50hp pump set with nut bolt etc all complete. , cost towards supply and fitting of 4diacoupling set for 60hp pump set with nut bolt etc all complete. , supplying, fitting, installation, erecting and commissionning ofapproved make h.t. outdoor type gang operated air break triple pole switch, suitable for 11kv line, rotating type, with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps including cp, ohc, transportation, labour charges etc. ( rate after deducting the scrap materials. ) , cost towards supplying and fitting of 250a mccb, 3phase, 50hz, isi marked, with all labour tools , tackles and technician charges. with cp & ohc, ( rate after deducting the scrap materials. ) . make l&t / abb / hpl / cg , cost towards supplying and fitting of 160a mccb, 3phase, 50hz, isi marked, with all labour tools , tackles and technician charges. with cp & ohc, ( rate after deducting the scrap materials. ) . make l&t / abb / hpl / cg , cost towards overhauling of motor control panel cum 3 nos. of f.a.s.d. starter panelwith all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wireconnection inside panel. cleaning, checking, rectifying of faults of 3nos. f.a.s.d. starter with supply and fitting of contacter set ( mnx95 1no and mnx50 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work eachfor 3 nos. fasd starter, dressingand doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . for mcp no. 1. , cost towards overhauling of motor control panel cum 2 nos. of f.a.s.d. starter panelwith all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wireconnection inside panel. cleaning, checking, rectifying of faults of 2nos. f.a.s.d. starter with supply and fitting of contacter set ( mnx70 1no and mnx50 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work each for 2 nos. fasd starter, dressingand doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . for mcp no. 2. , cost towards supplying and fitting of 30w led flood light, with bracket, copper wire, on off switch etc with all accessories including all labour tools , tackles and technician charges., with cp & ohc, ( rate after deducting the scrap materials. ) . make havells / syska / mescab / polycab / phillips , providing chipping work on the roof surface of clear water pump house, removing of all garbage to outside with lead of 50 m , providing and cleaning of concrete surface to remove dust and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. on identification of seepage, cement grouting to be done with non shrink expanding admixture of sika lndia pvt.ltd. / myk schomberg / dr fixit / fosroc or equivalent. , cost towards providing pcc m 200 in nominal mix of 1:1.5:3on roof with approved quality of stone chips 12mm to 6mm size graded andclean course sand of fm 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of e / i. , providing 12 mm thick water proof cement plaster ( 1:3 ) with clean coarse sand of f m. 1.5 with integral water proofing compound liquid @125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i.brand fosroc conplast x421 lc, sika plastocrate plus, dr fixit pidiproof lw+, myk proof wp 10 or equivalent , dismantling old plaster and pointing in cement or lime and taking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of e / i.inside and outside of pump house, , providing 6mm thick cement plaster ( 1:4 ) in ceiling and wall of building with clean coarse sand of f.m. 15 including screening, curingwith all leads and liftsof water, scaffoldingtaxes and royalty all complete as per buildingspecification and direction of e / i. , providing two coats ofsnowcemofapproved shade and make overold surfaceincluding washing cleaning and preparing the walls , scaffolding, curing and taxes all completeas per building specification and direction of e / i. , providing 2 ( two ) coats of synthetic enamel paint of approved shade & make oversteel surface including cleaning the surface, removing dirt, scales, smokes, grease, scaffolding & taxes all complete as per building specification and direction of e / i. for door, window, common header pipe, valves etc....

Drinking Water And Sanitation Department - Jharkhand

36990246 renovation of rural water supply scheme at khudgaddha , raw water pumping plant: , supplying all labor tools and tackles for taking out old and damaged vt pump sets from intake well with all accessories , demolition of mounting channel for installation of new vertical turbine pump sets. , supplying, installation, testing and commissioning of electrically driven vertical turbine pump sets kirloskar / wpil / mather & plate / jyoti having discharge capacity of raw water127 m3 / hragainsttotal head of 65 meters, coupled with vertical hollow shaft sq. cage induction motor make ( kirloskar / crompton / jyoti ) operated on 415 + 10% volts, 50hz, 1470 rpm with sole plate, discharge head, m.s. d.f. column assembly random length of 5 ft, total 40 ft. s.s. line shaft, s.s, socket, spider bearing with rubber cut less bush, cidf sluice valve 1 no, cidf nr valve 1 no, pressure gauge 1 no ets all complete. note: motor capacity should have 10% above of the pump. , supplying all labor tools and tackles for making pcc foundation 3x3x1 with all materials such as cement , sand, stone chips, foundation bolt, reducer as per sample, including fixing of sole plate for installation of new vt pump sets and jointing the existing delivery pipe line etc all complete job. , cost towards supplying andlaying of 16mm2 x3 core pvc insulated and pvc sheathed , 1.1 kv grade unarmored copper cable of reputed make and isi marked doing connection from panel to both motor. , cost towards making cable mouth for ( a ) 95 mm2 16 nos , ( b ) 16mm2 24nos , cost of doing internal light wiring of pump house with 7 / 18 single core copper wire will all required making short point 1 no, medium point 2 nos, long point 1 no with supplying and fixing 4x40 watt tube light 2 nos, 25 watt, led flood light with bracket 1 no etc all complete , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 02 nos. for pump set and 02 nos. for transformer ( one body earthing and one neutral earthing ) , cost for supply and fitting of 200amp. tpn main switch / switch disconnectorand doing all line connection. , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor . , cost towards supplying andlaying of 95 mm2 , 3 ½ core pvc insulated and pvc sheathed , 1.1 kv grade armeredaluminum cable of reputed make and isi marked doing connection from main switch to stabilizer andstabilizer to panel . , providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – ( a ) proper distribution 200 amp copper bus bar 4 pole 1 set ( b ) tpn mccb 250 amp l&t / siemens make withearth faultrelay for incoming feeder – 1no. ( c ) mccb 100 amp tp l&t / siemens make for outgoing feeder 2 nos. ( 1no for each pump sets ) ( d ) suitable size of fully automatic star delta starter l & t / bch / schnider make 2 nos. ( e ) with suitable kvr ( capacitor ) for improving power factor ( f ) 0 500 v voltmeter with selector switch 2nosct operated ampere meter ( 0 200a ) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , costtowards repairing and complete overhauling of 125 kva servo controlled automatic voltage stabilizer, disconnectingall electric line and joints and checking defects and removing them by s / f of damaged spare parts such as 10 kg operating motor 02 nos , connecting jack 03 nos, r c unite – 02 nos , variac auto transformer 01 no, control card 03 nos and doing internalwiring in propergauge of wire and reassembling the same and test on full load , including tools tackles and labor charges. , supply and top up transformer oil of reputed make , clear water pumping plant: , supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundationfor installation of new hsc centrifugal pump sets. , supplying, installation, testing and commissioning of electrically drivenhorizontal split casing centrifugalpump set make ( kirloskar / wpil / mather& plate / jyoti ) having discharge capacity of clear water33.5 lps againsttotal head of 35 meter coupled with tefc sq. cage induction motor make ( kriloskar / crompton / jyoti ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tire coupling 1 no etc all complete. , supplying all labour tools and tackles for making pcc foundtiaon 1 no. of size 4x3’x3 with all materials such as cement , sand, stone chips, foundation bolt 6nos, reducer and plastering and punning over exposed surface and jointing the existing delivery and suctionpipeline etc all complete job. , providing floor / wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – ( a ) proper distribution 200 amp copper bus bar 4 pole 1 set ( b ) tpn mccb 250 amp l&t / siemens make withearth faultrelay for incoming feeder – 1no. ( c ) mccb 100 amp tp l&t / siemens make for outgoing feeder 2 nos. ( 1no for each pump sets ) ( d ) suitable size of fully automatic star delta starter l & t / bch / schnider make 2 nos. ( e ) with suitable kvr ( capacitor ) for improving power factor ( f ) 0 500 v voltmeter with selector switch 2nosct operated ampere meter ( 0 200a ) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , cost towards supplying andlaying of 50 mm2 x , 3 ½ core pvc insulated and pvc sheathed , 1.1 kv grade armored aluminum cable of reputed make and isi marked doing connection from pole to panel board . , cost towards supplying and laying of 10 mm2 , 3 core pvc insulated and pvc sheathed, 1.1 kv grade unarmored copper cable of reputed make and isi marked for doing connection from panel to motor.jsor m1062 , cost towards making cable mouth for ( a ) 50 mm2 16nos , ( b ) 10mm2 24nos , cost of doing internal light wiring of pump house with 7 / 18 single core copper wire will all required making short point 1 no, medium point 2nos, long point 1 no with supplying and fixing 4x40 watt tube light 1 nos, 25 watt, led flood light with bracket 1 no etc including materials and labor chargesall compelte 1 job. , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 02 nos. for pump set and 02 nos. for transformer ( one body earthing and one neutral earthing ) , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor. , cost for supply and fitting of 200 amp. tpn main switch / switch disconnector and doing all line connection. , costtowards repairing and complete overhauling of 60 kva servo controlled automatic voltage stabilizer, disconnectingall electric line and joints and checking defects and removing them by s / f of damaged spare parts such as 10 kg operating motor 02 nos , carbon brush 03 nos, main transformer 01 no , control transformer 01 no and doing internalwiring in propergauge of wire and reassembling the same and test on full load , including tools tackles and labor charges. , supply and top up transformer oil of reputed make...

Drinking Water And Sanitation Department - Jharkhand

36990237 renovation of rural water supply scheme at bandh basti kathara , raw water pumping plant: , supplying all labor tools and tackles for taking out old and damaged vt pump sets from intake well with all accessories , demolition of mounting channel for installation of new vertical turbine pump sets. , supplying, installation, testing and commissioning of electrically driven vertical turbine pump sets kirloskar / wpil/ mather & plate/jyoti having discharge capacity of raw water60 m3/hragainsttotal head of25 meters, coupled with vertical hollow shaft sq. cage induction motor make (kirloskar / crompton/ jyoti) operated on 415 + 10% volts, 50hz, 1470 rpm with sole plate, discharge head, m.s. d.f. column assembly random length of 5 ft, total 40 ft. s.s. line shaft, s.s, socket, spider bearing with rubber cut less bush, cidf sluice valve 1 no,cidf nr valve 1 no, pressure gauge 1 no ets all complete. note: motor capacity should have 10% above of the pump. , supplying all labor tools and tackles for making pcc foundation 3x3x1 with all materials such as cement , sand, stone chips, foundation bolt, reducer as per sample, including fixing of sole plate for installation of new vt pump sets and jointing the existing delivery pipe line etc all complete job. , cost towards supplying andlaying of 06 mm2 x3 core pvc insulated and pvc sheathed ,1.1 kv grade unarmored copper cable of reputed make and isi marked doing connection from panel to both motor. , cost towards making cable mouth for (a) 50 mm2 16 nos , (b) 06 mm2 24nos , cost of doing internal light wiring of pump house with 7/18 single core copper wire will all required making short point 1 no, medium point 2 nos, long point 1 no with supplying and fixing 4x40 watt tube light 2 nos, 25 watt, led flood light with bracket 1 no etc all complete , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal/ coke and salt as required for chemical earthing. 02 nos. for pump set and 02 nos. for transformer (one body earthing and one neutral earthing ) , cost for supply and fitting of 200 amp. tpn main switch/ switch disconnectorand doing all line connection. , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor . , cost towards supplying andlaying of 50 mm2 , 3 ½ core pvc insulated and pvc sheathed ,1.1 kv grade armeredaluminum cable of reputed make and isi marked doing connection from main switch to stabilizer andstabilizer to panel . , providing floor/wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – (a) proper distribution 200 amp copper bus bar 4 pole 1 set (b) tpn mccb 100 amp l&t/ siemens make withearth faultrelay for incoming feeder – 1no. (c) mccb 100 amp tp l&t /siemens make for outgoing feeder 2 nos.(1no for each pump sets) (d) suitable size of fully automatic star delta starter l & t/ bch/schnider make 2 nos., (e) with suitable kvr (capacitor) for improving power factor (f) 0 500 v voltmeter with selector switch 2nosct operated ampere meter (0 200a) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , providing, erecting 30 kva servo controlled automatic voltage stabilizer suitable for output voltage 415v+/ 1% and input 280 450 v, 3 phase ,50 hz , with copper wound transformer (oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between the phases within range of 10%. the stabilizer should be constructed in cubical box ,with by bidirectional wheels for easy handlingnecessarymonitors and users controls on front panel such as indication , alarm ,voltmeterand selector switch formeasuring input and output voltage , auto/manual selector switch , raise/low push buttons etc.suitable capacity termination strips and bush bars for incoming & outgoing cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated as per is :9815 (a) over voltage /under voltage (b) single phasing (c) cut off contractor with electronicoutput sensing unite suitable change over switch and earthing. , supply and top up transformer oil of reputed make , clear water pumping plant: , supplying all labour tools and tackles for taking out old and damaged c/f pump set with all accessories , demolition of foundationfor installation of new hsc centrifugal pump sets. , supplying, installation, testing and commissioning of electrically drivenhorizontal split casing centrifugalpump set make(kirloskar/ wpil/ mather& plate/jyoti ) having discharge capacity of clear water50 m3/hragainsttotal head of 45 meter coupled with tefc sq. cage induction motor make (kriloskar/ crompton /jyoti) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no,cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tire coupling 1 no etc all complete. , supplying all labour tools and tackles for making pcc foundtiaon 1nos, of size 4x3’x3 with all materials such as cement , sand, stone chips, foundation bolt 6nos,reducer and plastering and punning over exposed surface and jointing the existing delivery and suctionpipeline etc all complete job. , providing floor/wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – (a) proper distribution 200 amp copper bus bar 4 pole 1 set (b)tpn mccb 200 amp l&t/ siemens make withearth faultrelay for incoming feeder – 1no. (c) mccb 100 amp tp l&t /siemens make for outgoing feeder 2 nos.(1no for each pump sets) (d) suitable size of fully automatic star delta starter l & t/ bch/schnider make 2 nos. (e) with suitable kvr (capacitor) for improving power factor (f) 0 500 v voltmeter with selector switch 2nosct operated ampere meter (0 200a) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , cost towards supplying andlaying of 70 mm2 x , 3 ½ core pvc insulated and pvc sheathed ,1.1 kv grade armored aluminum cable of reputed make and isi marked doing connection from main switch to stabilizer and stabilizer to panel board . , cost towards supplying and laying of 10 mm2 , 3 core pvc insulated and pvc sheathed,1.1 kv grade unarmored copper cable of reputed make and isi marked for doing connection from panel to motor. , cost towards making cable mouth for (a) 70 mm2 16nos , (b) 10mm2 24 nos , cost of doing internal light wiring of pump house with 7/18 single core copper wire will all required making short point 1 no, medium point 2nos, long point 1 no with supplying and fixing 4x40 watt tube light 1 nos, 25 watt, led flood light with bracket 1 no etc including materials and labor chargesall compelte 1 job. , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal/ coke and salt as required for chemical earthing. 02 nos. for pump set and 02 nos. for transformer (one body earthing and one neutral earthing ) , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor. , cost for supply and fitting of 200 amp. tpn main switch/ switch disconnector and doing all line connection. , providing, erecting 50 kva servo controlled automatic voltage stabilizer suitable for output voltage 415v+/ 1% and input 280 450 v, 3 phase ,50 hz , with copper wound transformer (oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between the phases within range of 10%. the stabilizer should be constructed in cubical box ,with by bidirectional wheels for easy handlingnecessarymonitors and users controls on front panel such as indication , alarm ,voltmeterand selector switch formeasuring input and output voltage , auto/manual selector switch , raise/low push buttons etc.suitable capacity termination strips and bush bars for incoming & outgoing cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated as per is :9815 (a) over voltage /under voltage (b) single phasing (c) cut off contractor with electronicoutput sensing unite suitable change over switch and earthing. , supply and top up transformer oil of reputed make...

Health Department - Jharkhand

36976606 rate contact for fire safter works fire safter works , fire fighting and hydrant system , supply, installation, testing and commissioning of pressure switches in ms pipe for hydrant electric pump/ sprinkler electric pump/ diesel engine drivenpump/ jockey pumps, diaphragm type adjustable range from 0 10kg/sq. cm and a regulation range of 0.1 1.5 kg/sq.cm direct mounted snap acting type made from die cast aluminium with epoxy powder coated finishand ss316 diaphragm and other materials parts, including necessary wiring upto control panel & materials as required as per specifications. approved make: indfoss/dandfoss , supplying & fixing internal and external stainless steel single headed fire hydrant landing valve with instantaneous stainless steel coupling of 63mm dia with cast iron wheel isi marked conforming to is:5290 (type a) with blank pvc cap and chain as required approved make: newage / safex / shah bhogilal / kartar , providing & fixing 63 mm dia stainless steel short branch pipe with 20mm with hose box lockable type single door (nominal internal diameter) in size stainless steel nozzle conforming to is:903 suitable for instantaneous connection complete to inter connect hose pipe, coupling etc. as required and as per enclosed specification. approved make: newage /safex / shah bhogilal , providing & fixing 63mm dia. 15mtr, long rrl hose pipe (isi marked) with 63mm dia. male and female stainless steel couplings , duly binded with gi wire, rivets etc. conforming to is 636 (type a) complete as required & as per enclosed specification. approved mark : newage / crc , providing and fixing first aid hose reel 20mm dia. x 30m long (minimum length) (thermoplastic type as per i.s. 12585) complete with drum, bracket, 25mm dia. shut off valve and 5mm gun metal nozzle conforming to is :884, connection with riser with ms c class pipe, painting the ms works complete as required & as per enclosed specification. approved make: newage / safex / shah bhogilal , providing and fixing 4 way gun metal fire brigade inlet connection comprising of 4 nos. 63mm dia. male instantaneous inlet couplings with cap and chain as required for 150mm dia. flanged conforming to is 904 complete (to be connected to static tank) as required and as per enclosed specification. approved make : newage / safex / shah bhogilal/kartar , providing and fixing fire brigade suction hose coupling (draw out connection) with nut for female coupling as per is 902 complete with 150mm dia. suction pipe and foot valve (to be connected to static tank) complete as required and as per enclosed specification . approved make: newage / safex / shah bhogilal/ kartar , supply, installation testing & commissioning of two way gun metal fire brigade inlet connection consisting of 63mm size instantaneously male coupling and shall be protected by cap scored with a chain glass bore etc. complete with one butter fly valve and 1 nos non return valve.( for external ring main, tower hydrant)approved make: newage/ safex/ shah bhogilal , pipes & valves , providing, fixing, jointing and commissioning of following sizes of c class heavy duty mild steel pipes conforming to is 1239/is 3589, including cutting welding, threading, hut bolts gasket, fitting, viz bends, ceiling/ beam/floor with suitable ms clamps / structural supports/ pcc block and painting complete as required and as per enclosed specification . approved make: tata/ jindal/apollo note: the pies size 150mm & below shall be m.s.c class as per is : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is:3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350mm dia. and from minimum 7mm thick ms sheet for pipes of 400mm dia and above. , 150 mm dia. , 100 mm dia. , 80 mm dia. , 50 mm dia. , 25 mm dia. , providing fixing testing and commissioning of following sizes of gate valve of rating pn 16, wafer type in cast iron body with ductile lron disc, epdm seal, ss single piece shaft conforming to is 13095 of the following sizes complete with cast iron hand lever companion flanges, bolts nuts washers & inserted rubber gaskets, as required and as per enclosed specification. approved make: leasderloto.oto/sant , 150 mm dia. , 100 mm dia. , providing, fixing, testing and commissioning of following size of ci non return valve conforming to api 594 with c.i. body, ss disc, ss stem, epdm seal, completewith companionflanges, bolts, nuts, washers & inserted rubber gasket complete as required and as per enclosed specification. (pn 16) approved make: leader/zoloto / sant 100 mm dia. , providing & fixing of 25mm dia. gunmetal , air release valve with all fitting and forged ball valve on header complete as required and as per enclosed specification. approved make: leader/zoloto / sant , providing and fixing following size pressure gauge (0 15 kg/cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification. 150mm dia. approved make: h.guru / feibig , providing, fixing & installation of control valve (sprinkler alarm valve) of cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, flanges, orifice plate, fittings, gasket etc. suitable for 150 mm diameter pipe size complete as required as per enclosed specification. approved make: hd / newage , automatic sprinkler system , providing & fixing of 15 mm dia. sprinkler head with standard response quartzite bulb operate at 68 degree c complete with all accessories as required and as per enclosed specification (ul listed) pendent type in chrome finish (standard coverage) approved make: hd / tyco/vking/newage , providing and fixing electrically operated flow indicating switches vane type with threaded connection for indicating water flow in sprinkler branch line with necessary junction box in stalled in accessible place. including cost of cable etc. complete. (wiring from switches to panel and stair case pressurisation not included). , approved make: honeywell/ sensotronic system/ switzer , providing and fixing 25mm dia inspecting & testing assembly with s.s. isolation valve s.s. sight glass byepass valve & connected to line drain complete in all respect as per standard practice of code including pressure gauges of approved make. approved make: reliable /hd/ul/listed , fire extinguisher , supply, installation, testing and commissioning isi marked (is:15683) fire extinguisher, carbon di oxide type capacity 4.5 kg. flat base including valve, discharge hose of not less than 10mm dia, 1m long and complete in all respects including initial fill with co2 gas conforming to is: 307 1966 and wall suspensionbraket as required as per specifications. approved make: minimax/ safex/ cease fire/ safeguard , blood bank (co2 trolly 9 kg) , new building (co2 4.5 kg) , red building (co2 trolly 9 kg) , c.s office (co2 trolly 9 kg) , other urban health institution of ranchi , supply, installation, testing and commissioning of 6kg abc (powder/dcp type) fire extinguisher , mid steel cylinders isi marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with abc 90 powder (mono ammonium phosphate) pressured by nitrogen complete in all respects including wall suspension bracket and conforming to is : 15683 as required as per specifications . approved make: minimax/ safex/ cease fire/ safeguard/safepro/ kanex , mechanical foam type fire extinguisher in hp mild steel cylinders isi marked / approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley , mounted and conforming to is:910 50 litres (trolley mounted) approved make: minimax / safex / cease fire / safeguard , fireterrace pump type:end suction speed (rpm): 2900 capacity: 900 ipm head : 35mtr. , providing fixing, testing and commissioning of control panel for terrace booster pumps. incoming: mccb 35a 1 set of phase indicating lamps, 1 set of 35al bus bars, 1 no ammeter, 1 no voltmeter withphase selector switch feeder for booster pumps 1no. 1 no. 32a tp mccb without releases, dol starter with over load relay , single phase preventer and indicating lamps with on/off push buttons. 1 no . automanual selector switch ,suitable for booster pumps water reservoir 1.00l , fire alarm and detection works , conventional type / addressable type manual alarm system , supply installation testing and commissioning of 24v manual call point mcp agni/morley/siemens , supply installation , testing & commissioning of 24 v hooter agni/morley/siemens , supply installation , testing & commissioning of 6/8 zone control panel agni/morley/siemens , wire 2x1.5mm armoud cable fire proof (anchor/poly cap / havlles) , supply installation , testing & commissioning of smoke + heat detector ionised type with base agni/morley/siemens , supply installation , testing & commissioning of response indicator 24v agni/morley/siemens , civil work , supply installation& commissioning of 5000 letters of sintex water container (four layer) for over head water storage for fire hydrant& fire sprinkler system , construction of rcc over head water tank with 20,000 l water capacity with superior quality concrete, steel & materials , fire suppression system , supply installation& commissioning of fire suppression system fk5112 specially for fire panal automatic type life guard / spectra/ novac , supply refilling and maintenance of fire extinguisher cylinder of all building of sadar hospital ranchi , fire safety mock drill of 100 people of sadar hospital ranchi given quarterly , maintenance of water reservoirof 200000 l & repairing if needed , general maintenance of fire fighting amc including, testing , repairing & refilling of cylinder only...

East Central Railway - Jharkhand

36870730 supply of three phase variac 0 480 v ac, 1 1 5 1 50a ( three phase variable supply ) 3 phase 4 wire with digital voltmeter & ammeter for showing the load 0 440v variable power supply enclosed type manual or motor operated suitable for testing 60kva three phase transformer & other electrical equipment oil cooled suitable for floor mounting. [ warranty period: 30 months after the date of delivery ] => limited...

Drinking Water And Sanitation Department - Jharkhand

36710992 supply, installation testing and commissioning of centrifugal pump sets with its allied work at boosting station clear water pumping plant of katras under d.w. & s. mechanical division, dhanbad for the year 2022 23. supply installation testing and commissioning of centrifugal pump sets with its allied work at boosting station clear water pumping plant katras , boosting station clear water pumping plant katras , supplying all labour tools and tackles for taking out old and damaged c/f pump set with all accessories , demolition of foundationfor installation of new hsc centrifugal pump sets. , supplying, installation, testing and commissioning of electrically drivenhorizontal split casing centrifugalpump set make(kirloskar/ wpil/ mather & plate/jyoti ) having discharge capacity of clear water45lps againsttotal head of 50 meter coupled with tefc sq. cage induction motor make (kriloskar/crompton/jyoti) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no,cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tire coupling 1 no etc all complete. , supplying all labour tools and tackles for making pcc foundtiaon 2nos, of size 5x3x3 with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface. , providing floor/wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – proper distribution 315 amp copper bus bar 4 pole 1 set micro processor base tpn mccb315 amp l&t/ siemens make withearth faultrelay for incoming feeder – 1no. mccb 315 amp tp l&t /siemens make for outgoing feeder 6 nos.(1no for each pump sets) 315 amp. (main switch)tpn isolater switch 1nos suitable size of fully automatic star delta starter l & t/ bch/schnider make 2 nos. 0 500 v voltmeter with selector switch 2nosct operated ampere meter (0 200a) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , cost towards supplying andlaying of 185 mm2 x , 3 ½ core pvc insulated and pvc sheathed ,1.1 kv grade armered aluminium cable of reputed make and isi marked doing connection from pole to panel board . , cost towards supplying and laying of 16mm2 , 3 core pvc insulated and pvc sheathed,1.1 kv grade unarmered copper cable of reputed make and isi marked for doing connection from panel to motor. , cost towards making cable mouth for 185mm2 8nos , 16mm2 24nos , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal/ coke and salt as required for chemical earthing. , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor . , cost for supply and fitting of 30 watt led flood light with bracket and doing line connection and testing. , cost for supplyin and laying of suction pipe line with supply and fiting of 6dia heavu duty gi pipe 6mtr, bend 1no, flange 6nos, but bolt+ washer 10 kg, rubber insertion 10kg cutting of pipe in required length and doing proper welding and fitting at site with at labour tools and tackles. , cost for delivery line with supply and fitting of 6dia heavy duty gi pipe 3mtr, bend 2nos, flange 4nos, nu bolt and washer 8kg.rubber insertion 8kg. and cutting of pipe in required size and welding work etc all complete...

Department of Higher Education - Jharkhand

36433511 bids are invited for 1 portable wattmeter 0 3kw, 0 5 / 10a, 75 / 150 / 300 v, upf 10 2 portable wattmeter 3 kw, 0 10 / 20 a, 300 / 600 v, upf 10 3 portable watt meter ( 3 phase ) 6kw, 0 10 / 20 a, 300 / 600 v 06 4 portable watt meter 0 2.5 / 5 a, 75 / 150 v, lpf 06 5 ac analog ammeter ( 0 5 / 10 ) a.ac 06 6 ac analog ammeter ( 0 15 / 30 ) a, ac 06 7 ac analog ammeter ( 0 1 / 2 ) a, ac 06 8 dc analog ammeter ( 0 2.5 / 5 ) a, dc 06 9 ac analog voltmeter 0 150 / 300 v, ac 08 10 ac analog voltmeter 0 300 / 600 v, ac 08 11 dc analog voltmeter 0 300 v, dc 06 12 rheostat 2a, 300 ohm 06 13 rheostat 0.1 a, 1000 ohm 06 14 rheostat 1.5 a, 356 ohm 06 15 3 arm rheostat 10 a, 50 ohm 06 16 3 phase loading rheostat input : 415v, ac output : 15 a / phase 5kw / 10 kw 06 17 1 phase auto transformer input : 240v, ac output : 0 270 v current capacity : 10 a 10 18 3 phase auto transformer input : 415v, ac output : 0 440 / 470 v current capacity : 10 a 05 19 dc rectifier unit...

Drinking Water And Sanitation Department - Jharkhand

36310525 dwsd dhanbad 03 2022 23 group c supply installation testing and commissioning of centrifugal pump sets with its allied work at boosting stating clear water pumping plant of katras , boosting station clear water pumping plant katras , supplying all labour tools and tackles for taking out old and damaged c/f pump set with all accessories , demolition of foundationfor installation of new hsc centrifugal pump sets. , supplying, installation, testing and commissioning of electrically drivenhorizontal split casing centrifugalpump set make(kirloskar/ wpil/ mather & plate/jyoti ) having discharge capacity of clear water45lps againsttotal head of 50 meter coupled with tefc sq. cage induction motor make (kriloskar/crompton/jyoti) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no,cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tire coupling 1 no etc all complete. , supplying all labour tools and tackles for making pcc foundtiaon 2nos, of size 5x3x3 with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface. , providing floor/wall mounted cubical l.t power control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – proper distribution 315 amp copper bus bar 4 pole 1 set micro processor base tpn mccb315 amp l&t/ siemens make withearth faultrelay for incoming feeder – 1no. mccb 315 amp tp l&t /siemens make for outgoing feeder 6 nos.(1no for each pump sets) 315 amp. (main switch)tpn isolater switch 1nos suitable size of fully automatic star delta starter l & t/ bch/schnider make 2 nos. 0 500 v voltmeter with selector switch 2nosct operated ampere meter (0 200a) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wireetc all complete job and testing on load. , cost towards supplying andlaying of 185 mm2 x , 3 ½ core pvc insulated and pvc sheathed ,1.1 kv grade armered aluminium cable of reputed make and isi marked doing connection from pole to panel board . , cost towards supplying and laying of 16mm2 , 3 core pvc insulated and pvc sheathed,1.1 kv grade unarmered copper cable of reputed make and isi marked for doing connection from panel to motor. , cost towards making cable mouth for 185mm2 8nos , 16mm2 24nos , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal/ coke and salt as required for chemical earthing. , supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor . , cost for supply and fitting of 30 watt led flood light with bracket and doing line connection and testing. , cost for supplyin and laying of suction pipe line with supply and fiting of 6dia heavu duty gi pipe 6mtr, bend 1no, flange 6nos, but bolt+ washer 10 kg, rubber insertion 10kg cutting of pipe in required length and doing proper welding and fitting at site with at labour tools and tackles. , cost for delivery line with supply and fitting of 6dia heavy duty gi pipe 3mtr, bend 2nos, flange 4nos, nu bolt and washer 8kg.rubber insertion 8kg. and cutting of pipe in required size and welding work etc all complete...

Central Coalfields Limited - Jharkhand

36270424 bids are invited for spares for prabhu make flp starter mse shunt trip assembly with coil part no flpvcb004 , vacuum interrupter 400a part no flpvcb006 , coil for shunt trip or spring release part no flpvcb017 , auxilary transformer for control circuit part no flpvcb023 , earth leakage relay part no flpvcb024 , epoxy molded cor balance transformer 3 point3 part no flpvcb025 , 3 pole magnetic over load relay part no htsp0019 , solid state overload and short circuit rel part no flpvcb026a , auxillary contc 3no plus 1nc plus110v coll part no flpvcb028 , diode based rectifier complete part no flpvcb029 , epoxy resin moulded c t for ammeter part no flpvcb032 , epoxy resin moulded 3 phase p t 3 point 3kv 11 part no vcbf00155 , pt fuse 3 point 3 kv part no flpvcb035 , led lamp holder with lamp vacuum circuit part no flpvcb043 , 72 sq mm ammeter ct operated part no flpvcb036 , 72 sq mm voltmeter 0 to 5 kv ptr 3 point 3kv 110v part no flpvcb037 total quantity : 123...

South Eastern Railways - Jharkhand

36238090 supply of 2 hp submersible pump2 hp submersible pump, 2 hp submersible pump, single phase with dol starter with voltmeter, ammeter, overload relay, head minimum 214 mtr. discharge: 0.5 0.9 m3 / hrs, discharge pipe dia 32 mm, make: kirloskar, cri, ksb or similar. [ warranty period: 24 months after the date of delivery ] ...

Department of Higher Education - Jharkhand

36224408 bids are invited for supply and installation of lab equipment leak transformer for sodium vapour lamp , spectrometer vernier , modern laser educational kit , diffraction grating , optical fibre characteristics kit , component tester , newtons rings apparatus , reading telescope with stand , reading telescope deluxe type , convex mirror highly silvered , concave mirror highly silvered , bar pendulum , lummer brodhum photometer set up , ammeter , voltmeter , rheostat , accumulator , commutator , current carrying coil , compass box for magnetometer , vernier calliper , screw gauge , spharometer , meter scale , lcr circuit kit , photoelectric effect experiment setup total quantity : 86...

East Central Railway - Jharkhand

36106373 supply of battery voltmeter ( uba ) , range 0 150v, specification / drg. : clw / es / 3 / sk / 0073 and drg. no. clw / es / 3 / ski / 0073 or latest. [ warranty period: 30 months after the date of delivery ] csd / trs / mgs , ecr uttar pradesh 58.00 numbers...

Ministry Of Coal - Jharkhand

36094935 bids are invited for spares for 11kv vcb shunt trip coil , vaccum interrupter , vaccum circuit breaker complete , indicating lamp , push buttons , trip natural close switch tnc , rectifire capacitor unit , 11kv, 110v, 100va per phase 3 phase pt , resin cast ct class p10, class1 , ammeter 96 sqmm , local remote switch , voltmeter 96sqmm , tpnd oc ef realy with high set , sensitive elr door mounted , pt fuse 11 kv , sensitive elr base mounted , om off isolater , over volatage relay , under voltage relay , pilot relay 110v dc , push to trip knob total quantity : 53...

Indian Army - Jharkhand

35997914 bids are invited for acsfp spare ammeter ac mi 0 100 amps ct ratio 96mm sq , frequency meter , voltmeter ac moving iron 10 300v 72 mm sq , bty charging regulaor , filter fluid pressure element lub oil f total quantity : 15...

Department of Higher Education - Jharkhand

35902955 bids are invited for item 1 portable wattmeter as per item 1 in specification document item 2 portable wattmeter as per item 2 in specification document item 3 portable wattmeter as per item 3 in specification document item 4 portable wattmeter as per item 4 in specification document item 5 ac analog ammeter as per item 5 in specification document item 6 ac analog ammeter as per item 6 in specification document item 7 ac analog ammeter as per item 7 in specification document item 8 dc analog ammeter as per item 8 in specification document item 9 ac analog voltmeter as per item 9 in specification document item 10 ac analog voltmeter as per item 10 in specification document item 11 dc analog voltmeter as per item 11 in specification document item 12 rheostat as per item 12 in specification document item 13 rheostat as per item 13 in specification document item 14 rheostat as per item 14 in specification document item 15 3 arm rheostat as per item 15 in specification document item 16 3 phase loading rheostat as per item 16 in specification document item 17 1 phase auto transformer as per item 17 in specification document item 18 3 phase auto transformer as per item 18 in specification document item 19 dc rectifier unit as per item 19 in specification document...

Kendriya Vidyalaya Sangathan - Jharkhand

35763580 bids are invited for school lab items mse burette 500ml , burtette stand , test tube , beaker 250 ml , beaker 100 ml , conical flask 125 ml , conical flask 250 ml , nh4oh 500 gm , red litmus , dropper , kerosene 500 ml , volumertic flask , high precision lab scalg digital analytical electromic balance , zn gramules , iron fillings , funnd glass , laboratary voltmeter , laboratory ammeter , prism , spherometer , concave mirror , convaex mirror , concave lens , convex lens , ph paper , universal indicator 500 ml , acetic acid 500 ml , methyl alcahol 500 ml , hydrochloric acid 500 ml , acetoarmine , suerose 500 gm , basic acid 500 ml , calcium nitrate 500 gm , magnesium sulphate 500 gm , potassium nitrate 500 gm , sodium choride 500 gm , starch 500 gm , iodine 100 ml , bendic solution 500 ml , felling solution a 500 ml , felling solution b 500 ml , ethyl alchohal 500 ml total quantity : 1078...

South Eastern Railways - Jharkhand

35760751 supply of voltmeter o 800 v ac 1.5. size 72 sq.mm ( square type ) . accepted make as per bom of rdso spec. no. rdso / pe / spec / ac / 0184 2015 ( rev 0 ) ae / muller+zeigler / rishabh / l&t / yokins ( copy attached ) . [ warranty period: 30 months after the date of delivery ] divisional gsd rnc , ser jharkhand 30.00 numbers...

South Eastern Railways - Jharkhand

35756868 supply of resistance 88 k.ohm. in 9 watts ( + / 1% ) for tm voltmeter for wap4 & wag7 locos to clws spec. no.clw / es / i 21 / a. [ warranty period: 30 months after the date of delivery ] amm / elins / bksc electric jharkhand 3.00 numbers loco ispat nagar stores , ser...

Central Coalfields Limited - Jharkhand

35584481 bids are invited for transswitch units 3 point 3 kv grade h t c t epoxy resin cas part no fcbp0021 , 3 point 3 kv epxy resin cast pt 3 point 3 kv 110 v 12 v part no fcbp0024 , 2 point 5 round amtr 0 400 200a ctr 2 00 100 5 a part no fcbp0030 , 2 point 5 round flush type voltmeter 0 to 4 kv ptr part no fcbp0032 , indicating lamp led 12 vac set rplus g plus a part no fcbm0042 , aux contactor 110 v ac part no fcbm0043 , limit switch 1 no plus 1 nc part no fcbm0056 , limit switch 02 no plus 02 nc part no fcbm0057 , elr 50ma to 750ma part no fcbt0078 , ntrl erthng rsstr mntrng relay 50 to 750ma part no fcbt0078 , shunt trip coil assembly part no v0021 spares for electroteknica make 3 point kv to 550v flp total quantity : 65...

Drinking Water And Sanitation Department - Jharkhand

35489091 e quotation for electro mechanical components by supplying and fitting and replacing of electro mechanical components of baharagora multi village rural water supply scheme 1 boosting p/plant w.t.pat mohanpur of bahragoda rwss cost towards supply installation and testing and commissioning of horizontal split casing type centrifugal pump make mather &platt/kirloskar /wpil capable of discharhing 100 m³/hr clear water against total head 30 meters, coupled with suitable 3 phase. 1440 rpm, 50hz tefc sq. cage induction motor make kirloskar, cgl/abb mounted on a common m.s. channel fabricated base plate with following accessories 1. sutable size n.r valve1 no2. sutable size sluice valve 1 no3. sutable size check valve/foot valve1 no4. pressure gauge1 no5. m.s base plate 1 no6. tyre coupling set 1 noetc all complete. 2 cost towards dismantling of old foundation and removing the residuals out of the pumping plant and making of new pcc foundation 4’x3’ x2.5’ size & m.s joint 4”x6” 2 nos. with supplying all mortar materials & foundation bolts 6 nos. with all labour tools and tackles loading unloading with alignment leveling and jointing as per p.w.d specification (1:2:4) etc all complete. 3 cost towards supplying installation & commissioning of 160 amp, 440 vmotor panel board made of 2mm thick ms sheet of suitable size, dust and vermin proof consisting of following accesories :(i)160 amp mccb – 1 no.(incoming feeder) (ii)100 amp mccb – 02nos (outgoing feeder). (iii)32 amp mcb 1 no. for lighting load and other utiliti load.(iv)fasd starter suitable for the 12.5 hp motor pumpset – 2 nos.(l&t make)(v)copper bus bar 4 pole 160 amp 415volt copper strip bus bar enclosed in ms sheet, etc. all complete job. (vi)led display voltmeter – (0 500 v) & amp meter(0 100a) – 2 sets, phase indicating lamp 6 nos.along with overload relay, single phase preventer proper inside wiring with suitable size of copper conductor with wall/floor mounting facility, cubical panel box etc. all complete including transportation and fitting and mounting charges at p/plant. 4 cost towards repairingof 63 kva transformer with changing of ht & lt bush 3 sets each , top up transformer oil upto 100 ltrs, fuse wires as per required. 5 cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to mcp 6 cost towards chemical earthing 40feet and 80mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangements including soldering, riveting, jointing g.i. flat strip 20mm x 3mm to all equipments. 7 cost towards supplying and installing 100 watt led street light complete set all complete including labour charges. for clear water p/plant. 8 cost towards supplying installation and commissioning of 63 kva servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 hz with copper wound transformer as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.the stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .all three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per is:9815a) over voltage/under voltageb)single phasing c) cut off contactorwith electronic output sensing unit d) suitable change over switch and earthing 100 kva oil cooled servo controlled automatic voltage stabilizer (output 415 unit+ 1%) input 280 to 450 volt. make: powerline/servokon 9 cost towards of changeover switch tpn on load with sheet sheel enclosure capacity amp for by pass arrangement of servo voltage stabilizer make c&s havell s/l&t with all labour & tools and materials. 10 supplying and laying of 25 sq.mmx3core x1.1 kv grade with isi make pvc insulated and unarmored flexible copper cable from mcp to motor terminal box with suitable copper lugs etc 11 part –braw water pumping plant – intake well at jamsola providing all labours, tools, tackels and technician fordisconnection and taking out20 hp vt p/set with column pipe into intake well all complete. 12 cost towards all labour, tools, tackles and technicianfor opening, dismantling. repairing and overhauling of20 hp 04 stage bow l assembly vt pump having head58 meter. discharge 43m3/hr speed 1460 rpmi. with s/f of s.s. pump shaft 01 no.ii. top and bottom bush 02 nos.,iii. intermediate bushes 5 nos.iv. spider cut less rubber bushes 04 nos.v. locks vi. impeller copper bush 06 pcs.vii. g.m. impeller 04 nos. viii. 30mm dias.s. line shaft 10 ft each 3 nos.ix. 30mm dia. ss.head shaft 5 ft. each i nos.x s. s socket and bush 04 nos. each. xi, ferro collar ball rubber bush 12pc xii. ball sleeve bush 07 nos each all materials as per required reassembling the same at workshop refitting at site etc. all complete(rate after deducting the scrap materials). 13 providing all labours, tools, tackels and technician forloweringafter repairing of20 hp vt p/set with column pipe into intake well all complete. 14 cost towards supplying all labour tools and tackles for complete opening, dismantling. of 20 hp 440 volt,50c/s, star delta, 3phase vt motor by supplying supperenameled copperwireandthentapping,varnishing, heating & testing on lull load and repairing of stator and rotor with including the deduction of cost of burnt copper wire approx. 18.5 kg.with changing of following bearing: (i) ball bearing as per sample 01 no. and (ii) thrust bearing as per sample (skf make) at raw water p/plant. 15 cost towards transportation charges of above pump motor set and other linings materials from p/plant to workshop and vice versa. 16 supplying and laying of 25 sq. mm x 3 core x 1.1 kv grade with isi mark pvc insulated and unarmoured flexible copper cable from mcp to motor terminal box with suitable copper thumble socket etc. 17 s/f of 90 watt ledfloodlighting luminaire with pressure die cast housing and toughened glass cover, operating voltage range 100v 270v ac with structure,stand, clamp, tee, wires and switches etc. all completeincluding repairing of lighting arrangements inside and outside of pump house at raw water p/plant. 18 costtowardssupplying andfitting of lighteningarrester suitable for building protection with earthingelectrode ,earthing compound, copper wires and earth work etc. all complete job. 19 cost towards replacement of old panel by supply installation & commissioning of new standing type floor mounting industrial panel board comprising 200 amp copper bus bar nos. in m.s steel(14swg) housing.•200 amp t.p.n mccb make l&t as incomer feeder.• 100 amp t.p.n mccb make l&t 2 nos as outgoing feeder.• ammeter digital ammeter with selector switch l&t/c&s make• voltmeter degital voltmeter in 3 phase ryb• indicating lamp led l&t/siemens/c&s make in red, yellow and blue colour 1 set.• 32 amp mcb for light load and other loads of l&t /havel’s/c&s make (2 no.)• fasd starter (make l&t) suitable for above pump set. panel should be dully painted with two coats super enameled paint of approved color one coat of red oxide primer and internally wired with suitable size of copper wire etc. all complete. 20 cost towards supplying triple spur gear type chain pully block of 3 tonne capacity with 6m lift complete with load chain and hand chain suitable for above lift, tested to 50%over load as per is 3832 carrying isi mark with travelling trolley etc. 21 cost towards of changeover switch tpn on load with sheet sheel enclosure capacity amp for by pass arrangement of servo voltage stabilizer make c&s havell s/l&t with all labour & tools and materials. 22 cost towards supplying and laying of 3core 95 sq.mm aluminium armoured cable from transformer to mcp 23 cost towards supplying installation and commissioning of 63 kva servo controlled (oil cooled) automatic voltage stabilizer suitable for output voltage of 415 + 1% 3 phase, 50 hz with copper wound transformer as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%.the stabilizer should be constructed in cubical box,with bidirectional wheels for easy handling necessary monitors and user’s controls on front panel such as inducation alarm, voltmeter and selector switch for measuring input and output voltage auto manual selector switch.raise low push buttons etc. suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided .all three phases shall be independently monitored and corrected following protections and indication shall be incorporated as per is:9815a) over voltage/under voltageb)single phasing c) cut off contactorwith electronic output sensing unit d) suitable change over switch and earthing 100 kva oil cooled servo controlled automatic voltage stabilizer (output 415 unit+ 1%) input 280 to 450 volt. make: powerline/servokon ...

Indian Army - Jharkhand

35472974 bids are invited for ord store insulation tape , qucik fix , voltmeter , frequency meter , ammeter , stop solnoid total quantity : 35...

Central Coalfields Limited - Jharkhand

35267572 providing and installation of programmable energy meter, under voltage and over voltage relays, digital ammeter and voltmeter for different panels installed at 2 x 12.5 mva, 33kv / 6.6kv main substation of rajrappa project...

Central Coalfields Limited - Jharkhand

34880907 bids are invited for spares for electroteknica make flp transwitch isolator 3.3kv 400a on off , isolator moving contact , isolator fixed contact , core balance current transformer ht side , 3.3 kv grade epoxy resin cast pt ratio 3.3kv, 110v , 3.3kv pt fuse 3 amps , 2.5 round flush type ammeter 0 400 200a , 2.5 round flush type voltmeter , base mounted elr , relay for intrinsically safe circuit , indicating lamp led 12vac , aux. contactor 110vac , limit switch , micro switch , elr 50 ma to 750ma total quantity : 52...

Bharat Sanchar Nigam Limited - Jharkhand

34865200 tender for breakdown maintenance of eii / c replacement of faulty and old tube light fittings , repairing of fans , rewiring and out door light at main te building , ranchi under ranchi ba replacement of following faulty electrical items by new one i / c testing etc complete as reqd. 2 a ) 20 watt led tube light batten type fitting 3 b ) 20 watt led tube light retrofit type 4 c ) retrofit type 20watt tube light fitting 5 d ) led bulb 9 watt 6 e ) 15 a socket 7 f ) 15 / 16 amp switch 8 g ) 5 amp switch 9 h ) 5 amp socket 10 i ) fan regulator 11 through checking of faulty tube lights , street light and wiring etc i / c detection of fault, disconnection of wiring , cleaning and fittings etc as per site required. 12 s / f of 50 watt street light led type fittingmade up of diacast housing with toughned glass and individual leds with secondary optics and ip66 / 65 protectionsuitable for 230 volts 50 hz connectioni / c gi pipe 40mm dia etc as reqd. ( m / shavels or ss make ) 13 s / f of 100watt flood light led type fittingmade up of diacast housing with toughned glass and individual leds with secondary optics and ip66 / 65 protectionsuitable for 230 volts 50 hz connectioni / c gi pipe 40mm dia etc as reqd. ( havels or ss make ) 14 supply and installation of ceiling fan of 1200mm sweep , 50 watt, min 370 rpm, min. air delivery 215cmmsuitable for 230v , 50hz power supply as per site reqd. ( cropmton entrust 50 or ss make ) 15 repairing / rewinding / servicing of faulty ceiling / wallmounted / exhust fans i / c testing, commissioning etc as reqd. 16 a ) 1200 / 1400 mm ceiling / wall mounted fan 17 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 18 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 19 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 20 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 21 2 x 1.5 sq. mm 22 3 x 1.5 sq. mm 23 3 x 4 sq. mm 24 6 x 4 sq. mm 25 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 26 single pole 27 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 28 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 29 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 30 replacement of control panel for 5 hp submersible pump making 16 guage ms sheet i / c starter, voltmeter, ammeter, selector switch and short cicuit protection etc as reqd. ( make: bch cat cpeynajn or similar superior make ) 31 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 32 8 way , double door 33 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 34 40 a 35 63 a 36 supplying and fixing brass batten / angle holder including connection etc. as required....

South Eastern Railways - Jharkhand

34311165 supply of voltmeter range 0 150 dc volts, voltmeter range 0 150 dc volts, , 72 x 72 mm analogue type front panel voltmeter range 0 150 dc volts, flush type with rubber gasket accuracy class 1.5 as per is:1248 ( p 2 ) 2003, nw 72, suitable for lhb ac coaches as per specification no. rdso / pe / spec / d / 0184 2015 ( rev 1 ) make ae nw72, muller, zeigler, rishabh l&t , yokins....

Hindustan Urvarak and Rasayan Limited - Jharkhand

34163378 supply and installation of low voltage switchboard at hurl sindri project supply and installation of low voltage switchboard at hurl sindri project , supply, loading, handling, storage, transportation within site, erection, installation, testing and commissioning etc. of following lt panel , 415 v, 3 ph. & n, ip54, floor mounted sheet steel enclosed main power board with al bus bar of 250a which consists of 2 nos. incoming 4p, 250 a, 50ka mccb incomer with earthfault, overcurrent protection and mechanical interlock with 250 / 1 ct, mfm, voltmeter, vss & ryb indications & 8nos. 63 a tpn rccb outgoing feeders indications & 7 nos. 63 a tpn sfu outgoing feeders on indoor bus & 2 nos. 4p, 100a, 30ka mccb outgoing feeders on outdoor bus with timer controlled feeders with suitable power contactor to operate outdoor bus. , 415 v, 3 ph. & n, ip55, outdoor type, structural mounted, weatherproof ( ip 55 ) lighting distribution board type db with bus bar 200 a, 415v having 2 nos. tpn, incomer 3p, 100a, 30kamccb withvoltmeter, vss & ryb indications and6 nos. 63 a tpn rccboutgoing feeder circuit and 16a, dp mcb, 6nos. , 415 v, 3 ph. & n, ip54, floor mounted sheet steel enclosed main power board with al bus bar of 400a which consists of 2 nos. incoming [ 4p, 400a, 50ka mccb incomer and 4p, 250a, 50ka mccb ] incomer with earthfault, overcurrent protection and mechanical interlock with 400 / 1 ct& 250 / 1 ct, mfm, voltmeter, vss & ryb indications &10 nos. 100 a mccb outgoing feeders & 4 nos. 63 a tpn rccb outgoing feeders& 2nos. 3p, 36a sfuoutgoing feeders and 16a, dp mcb, 6nos. , 415 v, 3 ph. & n, ip54, floor mounted sheet steel enclosed main power board with al bus bar of 100a which consists of 2 nos. incoming 4p, 100 a, 30ka mccb incomerwith earthfault, overcurrent protection and mechanical interlock with 100 / 1 ct, mfm, voltmeter, vss & ryb indications & 63 a tpn rccb outgoing feeders& 2 nos. 3p, 63a sfuoutgoing feeders and 32a, dp mcb, 6nos. , 415 v, 3 ph. & n, ip54, floor mounted sheet steel enclosed main power board with al bus bar of 630a which consists of 2 nos. incoming 4p, 630 a, 50ka mccb incomer with earthfault, overcurrent protection and mechanical interlock with 630 / 1 ct, mfm, voltmeter, vss & ryb indications & 10 nos. 63 a tpn rccb outgoing feeders indications & 6 nos. 250 a tpn sfu outgoing feeders & 2 nos. 3p, 63a sfuoutgoing feeders and 32a, dp mcb, 6nos....

Uranium Corporation Of India Limited - Jharkhand

33697571 spares of 55 kw nflp gate end box spares of 55 kw nflp gate end box , spares of 55 kw nflp gate end box , pr pilot relay with base , heavy duty screw assy. complete with handle, bush, lock etc for 200 amps plug socket , dmc moulded plug insulation ( w.o.pin ) for 200 amps plug & socket , brass pin for plug ( set of 4 pins ) of 200 amps plug & socket , dmc moulded socket insulation ( w.o.pins ) for 200 amps plug & socket , brass pin for socket ( set of 4 pins ) of 200 amps plug & socket , 72 sq.mm ammeterrange : 0 300 900a ( w.o.ct ) , inter lock assy for isolator handle , auxiliary contactor 3no+1nc with 110v coil type ca2 dn1319 fitted with add on block la1d11 , 72 sq.mm voltmeter range: 0 500ac , contactor type tcla1 d22 with auxiliary contact 2no+2nc coil voltage 440v ac , metallic togle switch complete with chacker nut of any reputed make 2 way 10a 440v , earth leakage relay 50ma to 750ma with time delay 0.1sec to 1sec auxiliary voltage 12v ac , 200 amps plug and socket complete set with leads for socket , 200 amps socket complete set with ieads , single phase preventer aux. supply voltage 440v type vsp3 make : minilec , control transformer primary voltage 0 to 415v 440v 460v / secondary 0 to 8v 12v and 0 to 110v va 100va , limit switch for isolator , led indicating lampoperating voltage : 12v ac colour : red , led indicating lamp operating voltage : 12v ac colour: green , led indicating lamp operating voltage : 12v ac colour : yellow...

Central Coalfields Limited - Jharkhand

33566712 bids are invited for procurement of spares for electroteknica 1 nvcbv0001 shunt trip coil assembly 2 2 nvcbv0004 breaker charging handle 2 3 nvcbv0013 vacuum interrupter 1 4 nvcbv0014 96sq.mm ammeter upto 0 600 / 120a, ctr 600 / 5a 1 5 nvcbv0015 96sq.mm ammeter upto 0 300 / 600a, ctr 300 / 5a 1 6 nvcbv0017 96sq.mm voltmeter 0 5ka, ptr3.3kv / 110v ac 2 7 nvcbi0018 ammeter selector switch 2 8 nvcbi0019 voltmeter selectoe switch 2 9 nvcbi0020 mushroom head push button 2 10 nvcbp0032 tnc switch for elec.operated vcb 2 11 nvcbp0034 rectifier capacity unit 15a 2 12 nvcbp0035 earth leakage relay 1 13 nvcbp0037 3.3 kv / 110v12v, 100va / ph 3 ph pt 2 14 nvcbp0044 3.3 kv, 3 amps. p.t fuse 6 15 nvcbp0057 hrc fuse link 10 amps. 6 16 nvcbp0074 limit switch 2 17 ivb0001 shunt trip / series trip coil 2 18 ivb0003 auxillary switch assembly 1 19 ivb0021 breaker charging mechnism 2 20 ivb0022 catch mechanism 2 21 ivb0059 tpnd o / c & e / f relay with high set 2 22 ivb0040 11kv / 110v, 100va per phase 3 phase p.t 2 23 ivb0041 resin cast c.t class 5p 10 / class 1.0 3 24 ivb0068 master tripping relay 1 total quantity : 51...

South Eastern Railways - Jharkhand

33178939 supply of starter for 5hp submersible pump with ammeter, voltmeter etc.starter for 5hp submersible pump with ammeter, voltmeter etc., starter for 5hp submersible pump with ammeter, voltmeter, single phase preventer, indicating lights and dry run protection unit ( make l&t ) make bch or l&t or greaves or equivalent....

Welfare Department - Jharkhand

33028328 bids are invited for measuring steel tape , combination plier insulated , screw driver insulated , electrician screw driver thin stem insulated handle , heavy duty screw driver insulated , electrician screw driver thin stem insulated handle , punch centre , knife double bladed electrician , neon tester , steel rule graduated both in metric and english unit , hammer, cross peen with handle , hammer, ball peen with handle , pincer , c clamp , spanner adjustable drop forged, ss , blow lamp brass , chisel cold , chisel firmer with wooden handle , allen key alloy steel , grease gun , bradawl , pully puller with 3 legs , bearing puller inside and outside , pipe vice cast iron with hardened jaw open type , scissors blade, ss , crimping tool , wire cutter and stripper , mallet hard wood , hammer extractor type , hacksaw frame , try square , outside calliper , inside calliper , divider , pliers long nose insulated , pliers flat nose insulated , pliers round nose insulated , tweezers , snip straight and bent heavy duty , de metric spanner double ended , drill hand brace , drill ss twist block , plane cutters , smoothing cutters , gauge wire imperial stainlees steel marked in swg and mm , file flat , file half round , file round , file flat rough , file flat bastard , file flat smooth , file rasp, half round , copper bit soldering iron , de soldering gun , hand vice , table vice , oil can , contactor and auxiliary contacts , limit switch , rotary switch , relay a cut out relays b reverse current c over current d under voltage , pin, shackle, egg and suspension type insulators , hydrometer , hand drill machine , portable electric drill machine , load bank lamp or heater type , brake test arrangement with two spring balance rating , laboratory type induction coil , out side micrometer , thermometer digital , series test lamp , knife switch dpdt fitted with fuse terminals , knife switch tpdt fitted with fuse terminals , miniature breaker , earth plate , earth electrode , mccb , elcb and rccb , fuses , rheostat sliding type , various electronics components , capacitors , various lamps , plug socket piano switch lamp holder , cables twisted pair nonmetallic sheathed cable underground feeder cable ribbon cable metallic sheathed cable multiconductor cable coaxial cable directburied cable , bus bar with brackets coaxial cable directburied cable , bus bar with brackets , rubber mat , electrician helmet , rcc pole with accessories ms angle iron, c clamp, stay insulator etc and materials , safety belt , ohm meter series type and shunt type , digital multi meter , ac voltmeter mi analog, portable box type housed in bakelite case , milli voltmeter centre zero analog, portable box type housed in bakelite case , ammeter mc analog, portable box type housed in bakelite case , ac ammeter mi, analog, portable box type housed in bakelite case , kilo wattmeter analog , digital wattmeter , ac energy meter , power factor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer , tong tester clamp meter , megger , 3 point dc starter , 4 point dc starter , wheat stone bridge with galvanometer and battery , single phase variable auto transformer , phase sequence indicator , growler , ac starters resistance, dol, manual star delta, semi star delta, fully star delta, soft, auto transformer starter , oscilloscope dual trace , function generator , soldering iron , temperature controlled soldering iron , discrete component trainer , linear ic trainer , digital ic trainer , a electric induction plate , b electric kettle , c electric iron , d immersion heater , e ac ceiling fan and ac table fan , f geyser storage type , g mixture and grinder , h washing machine semi automatic , i motor pump set , oil testing kit , inverter with battery , voltage stabilizer , dc power supply , battery charger , current transformer , potential transformer , solar panel with battery , pentium iv computer or latest , ink jet laser printer , dc shunt generator with control panel , motorgenerator ac to dc , dc compound generator with control panel including fitted rheostat, voltmeter, ammeter and breaker , dc series motor coupled with spring balance load , dc shunt motor , dc compound motor with starter and switch , motor generator dc to ac set , ac squirrel cage motor with star delta starter and triple pole iron clad switch fuse with mechanical load , ac phasewound slip ring motor with starter switch , universal motor with starterswitch , synchronous motor with accessories like starter, excitation arrangements , thyristor igbt controlled dc motor drive with tachogenerator feedback arrangement , thyristorigbt controlled ac motor drive with , single phase transformer, core type, air cooled , three phase transformer, shell type oil cooled with delta star , electrical machine trainer , used dc generatorsseries, shunt and compound type for overhauling practice , pillar electric drill machine motorized , motorised bench grinder , ac series type motor , single phase capacitor motor with starter switch , manual motor coil winding machine , ceiling fan coil winding machine , primary current injection set , stepper motor with digital controller , shaded pole motor , working bench , wiring board , black boardwhite board , fire extinguisher co2 , fire buckets , diesel generator set with change over switch, over current breaker and water aircooled with armature, stardelta connections ac 3 phase , metal rack , locker with drawer...

Drinking Water And Sanitation Department - Jharkhand

32694711 supplying, installation, testing and commissioning submersible pump set for rural water supply scheme manushmudya, pumping plant. under d.w and s mechanical division, jamshedpur 1 supply of submersible pump set suitable for 6 dia bore well running with 3 phase415± 10% volts50 c / s 2900 rpm having discharging capacity 2600 gph against total head of 60 meters with noryl / g.m impeller consists of following accessories ( a ) 2½ dia g.i column pipe 200 ( 10 long both end threaded one end fitted socket and other end covered by plastic ) ( b ) 3 core flat copper cable 4 mm² 1 coil ( c ) m.s clamp 2½ dia 2 pairs ( d ) c.i.d.f sluice valve 2½dia 1no. ( e ) ) c.i.d.freflexvalve 2½dia 1no. 2 supplying and fitting cubical type duly painted control panel boardconsisting 32 amps. tpn mccb inbuilt single phase preventor and suitable forstar delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meterwith selector switch make l&t / havell;s 3 chemical earthing3 metersand80 mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangement including soldering, riveting, jointing g.i flat 50 mm x 6 mm to all equipments. 4 supplyingtriple spur gear type 3 tonne capacitychain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 5 renovation of light wiring inside & out side pump chamber by doing short point light wiring 4 point long point light wiring 4 points, 150 watt led street light complete set 2 nos., 36 watt cfl 4 nos. etc. all including labour charges all complete 6 supplying and making tripod ( 14x 65 mm c.i pipe ) hanging chain pulley block 7 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 25 mm² x 3½ core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved. from transformer to p / house via gangway. 8 supplying installation testing and commissioning of 30 kva servo controlled automatic voltage stabilizer oil cooled power line / ipc / servokon make suitable for output voltage of 415 volt ± 1% under input voltage range of 280 450 volts ( phase to phase ) 3 phase, 50 hz, with copper wound transformer. the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should have indicator, alarm, voltmeterand auto / manual selector switch for measuring input and output voltage, raise / low push buttons etc. suitable capacity terminationstrip and bus bars for incoming and outgoing cable should be provided. all three phase shall be independently monitored and corrected. following protections and indications shall be incorporated :over voltage / under voltage single phasing cut off conductor with electronic output sensing unit. 9 supplying and fixing 100 amp. 415± 15% voltage change over switch, havells / l & t make 10 transformer oil for the above stabilizer of best make up to mark. 11 supplying, installation, testing & commissioningof outdoor type 63 kva 11 / 0.433 kva copper wound distribution transformer with off load tap changer 12.5% to 2.5% in step of 2.5%, continuously rated for three phase, 50 hz, full load and temperature rise not exceeding 45 degree centigrade by thermometer in oil and 50 degree centigrade by the resistance in winding after continuous, run atfull load rating, the transformer should have oil immersed winding having vector group of 0.4 / 11, ht side connected in delta & lt side connected in star with neutral brought out connected. the transformer should have power terminal bushing arrangement on ht side & cable box in lt side with standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. all complete with all materials make – indian transformer / synergy / banglabijulee / kirloskar for ruralwatersupply p / pmanushmudia....

Drinking Water And Sanitation Department - Jharkhand

32639583 government of jharkhand through its public works department ( pwd ) is engaged in framing / revision of schedule of rates and as part of this endeavor, quotations through e tender are invited for replacement of damaged electro mechanical items of ( a ) babhangama rural ( mvs ) water supply scheme, ( b ) sarath rural ( mvs ) water supply scheme and ( c ) kairow rural ( mvs ) water supply scheme ( material supply, installation and commissioning of pump set works pertaining to drinking water supply a babhangama rural ( mvs ) water supply scheme 1 pump & motor : 1.01 supplying, installation, testing and commissioning of electrically driven vertical turbine pump sets kirloskar / wpil / mather & plate / jyoti having discharge capacity of raw water 50 m3 / h against total head of 40 meter, in all concern coupled with vertical hollow shaft sq. cage induction motor make ( kirloskar / crompton / jyoti ) operated on 415 ± 10% volt, 50hz, 1460 rpm ( 10% above the capacity of pump ) with sole plate, discharge head, m.s. d.f. column assembly random length of 5ft, total 50ft s.s. line shaft, s.s. socket, spider bearing with rubber less bush, cidf sluice valve 1no, cidf nr valve 1no, pressure gauge 1no & fixing the discharge new pump to the existing common header etc. complete. motor control panel 100 amp. 2.01 cost towards replacement of old panel by supply, installation & commissioning of new floor mounted motor control panel comprising 100 amp copper bus bar 04 nos. in m.s. steel ( 16swg ) cubical box ( 3’ x 2.5’ x 1’ )  t.p.n. main switch sdf type in ss enclosure make l&t 100 amp 1 no.  three pole mccb ( make l&t ) 63 amp 1 no. for incomer feeder.  three pole mccb ( make l&t ) 32 amp 2 nos. for starter.  fasd starter ( make l&t ) suitable for 15 hp pump set. 02 nos.  ammeter 03 nos. ( 0 50amp ) 01 no., ( 0 30amp ) 02 nos.  voltmeter ( 0 500v ) 1 no. mcp should be comprising with selector switches, phase indicator ( ryb ) , push button ( start & off ) , on off indicator for starter, provision of lighting arrangement ( 25amp mcb ) etc. all complete. for clear water p / plant 2.02 cost towards replacement of old panel by supply, installation & commissioning of new floor mounted motor control panel comprising 100 amp copper bus bar 04 nos. in m.s. steel ( 16swg ) cubical box ( 3’ x 2.5’ x 1’ )  t.p.n. main switch sdf type in ss enclosure make l&t 100 amp 1 no.  three pole mccb ( make l&t ) 100 amp 1 no. for incomer feeder.  three pole mccb ( make l&t ) 63 amp 2 nos. for starter.  fasd starter ( make l&t ) suitable for 15 hp pump set. 02 nos.  ammeter 03 nos. ( 0 50amp ) 01 no., ( 0 30amp ) 02 nos.  voltmeter ( 0 500v ) 1 no. mcp should be comprising with selector switches, phase indicator ( ryb ) , push button ( start & off ) , on off indicator for starter, provision of lighting arrangement ( 25amp mcb ) etc. all complete. for raw water p / plant for raw water p / plant b sarath rural ( mvs ) water supply scheme 1 pump & motor : 1.01 supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & platt / jyoti ) having discharge capacity of clear water 35 m3 / h against total head of 40 meter coupled with tefc sq. cage induction motor make ( kirloskar / crompton / jyoti ) operated on 415 + 10% volts, 50hz, 1440 rpm mounted on common m.s. fabricated base plate with cidf sluice valve 1 no, cidf nr valve 1 no, pressure gauge 1 no, tire coupling 1 no, etc. all complete. 2 motor control panel 100 amp. 2.01 cost towards supplying, fitting & commissioning of motor control panel for operating 2 nos. pump set with fasd starter to operate installed c / f pump set having 63 amp mccb as main incomer, 40 amp mccb as main switch of starters, led indicator, amp meter ( 0 30 amp ) for each pump & volt meter ( 0 500 volt ) selector switch motor control panel should have copper bus bar arrangement. the panel box should be made of swg 18 iron sheet, size 2’ x 1½’ x 1’ with 3 layer pvc paint. all electrical elements should be fitted in iron box. control panel box should be of wall hanging type. kairow rural ( mvs ) water supply scheme pump & motor : supplying, installation, testing and commissioning of electrically driven vertical turbine pump sets kirloskar / wpil / mather & plate / jyoti having discharge capacity of raw water 60 m3 / h against a total head of 45 meter, in all concern coupled with vertical hollow shaft sq. cage induction motor make ( kirloskar / crompton / jyoti ) , operated on 415 ± 10% volt, 50hz, 1460 rpm ( 10% above the capacity of pump ) with sole plate, discharge head, m.s. d.f. column assembly random length of 5ft, total 50ft s.s. line shaft, s.s. socket, spider bearing with rubber cut less bush, cidf sluice valve 1no, cidf nr valve 1no, pressure gauge 1no etc. all complete....

Drinking Water And Sanitation Department - Jharkhand

32583653 complete renovation work with supply installation testing and commissioning of pump sets, motor control panels, cables and its allied works at raw water and clear water pumping plant at multi village rural water supply scheme, pandra 1.a raw water pumping plant: 1.01 cost towards supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & plate / jyoti ) coupled with tefc sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with 4dia or suitable size of cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 no etc all complete. head 18 m discharge 120 m3 / h ( hp 15 approx ) 1.02 supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundation for installation of new hsc centrifugal pump sets. 1.03 supplying all labour tools and tackles for making new pcc foundation of size 4′ x 2.5 x 2.5′ with all materials such as cement , sand, stone chips, foundation bolt 6 nos etc all complete and plastering and punning over exposed surface with all labour tools, tackles and technician charges. 1.04 cost for supply and laying of suction pipe line with supplying of 5 dia or suitable dia size as per pump at site, heavy duty g.i. pipe 6 m, bend 2 nos., flange 6 nos., nut, bolt, washer 10kg, rubber insertion 5kg etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges. with cp & ohc. ( rate after deducting the scrap materials. ) 1.05 cost for supply and laying of 4dia delivery pipe line with supplying of 4 dia or suitable dia size as per pump at site, heavy duty g.i. pipe 6m, bend 1 nos., flange 4 nos., nut, bolt, washer 5kg, rubber insertion 5kg etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges. with cp & ohc. ( rate after deducting the scrap materials. ) 1.06 cost for supplying and laying of 3 core x 10 mm2, pvc insulated and pvc sheathed unarmoured copper cable of 1.1 kv grade. from panel to motor in 2 length each for both motor. with cp and ohc. 1.07 socketing of terminal ends with s / f of terminal socket including all labour , tools and tackles. 3 core x 10 mm2copper cable. 1.08 cost for supplying and laying of 3.5 core x 25 mm2, pvc insulated and pvc sheathed armoured aluminum cable of 1.1 kv grade. from electric pole to panel with cp and ohc. 1.09 socketing of terminal ends with s / f of terminal socket including all labour , tools and tackles. 3.5 core x 25 mm2aluminium cable. 1.10 cost towards supplying, installation, testing and commissioning of tpn main switch / isolator of 100a , make ( havells / schnieder / l&t / any reputed make isi marked. ) . 1.11 providing floor / wall mounted cubical l.t motor control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – proper distribution 100 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 100 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 63 amp tpn type l&t / siemens make for outgoing feeder 3 nos. ( 1no for each pump sets+1 no. as spare ) suitable size of fully automatic star delta starter make l&t / bch / schnider make 3nos. 0 500 v voltmeter with selector switch 3nos ct operated ampere meter ( 0 200a ) with ct 3 sets with selector switch 3 nos, phase indicating neon lamp 9 nos., s.p.p. 3 nos. doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 1.12 cost for doing chemical earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 1.13 supplying and laying of 8 swg copper wire / gi wire for making earthing connection in to from earthing station to panel to motor . 1.14 cost towards doing complete electric wiring inside and outside of pump house with s / f of copper cable, switches, bulb holder, sockets, indicator lamp, led bulb 2, led tube light 1no., 40w led flood light 1no. etc all complete including transportation and electrician charges. 1.b clear water pumping plant: 1.01 cost towards supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & plate / jyoti ) coupled with tefc sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with suitable size of cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 no etc all complete. head 50 m discharge 54 m3 / h ( hp 20 approx ) 1.02 supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundation for installation of new hsc centrifugal pump sets. 1.03 supplying all labour tools and tackles for making new pcc foundtiaon 2nos, of size 5′x3x3′ with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface. 1.04 cost for supply and laying of suction pipe line with supplying of 4 dia or suitable dia size as per pump at site heavy duty g.i. pipe 6m, bend 2 nos., flange 6 nos., nut, bolt, washer 10kg, rubber insertion 5kg etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) 1.05 cost for supply and laying of 3dia delivery pipe line with supplying of 3 dia or suitable dia size as per pump at site heavy duty g.i. pipe 6m, bend 1 nos., flange 4 nos., nut, bolt, washer 5kg, rubber insertion 5kg etc, cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges. with cp & ohc. ( rate after deducting the scrap materials. ) for pump house no 1 & 2. 1.06 cost for supplying and laying of 3 core x 10 mm2, pvc insulated and pvc sheathed unarmoured copper cable of 1.1 kv grade. from panel to motor in 2 length each for both motor for both pump house with cp and ohc. 1.07 socketing of terminal ends with s / f of terminal socket including all labour tools and tackles. 3 core x 6 mm2, copper cable 24 ends. 1.08 providing floor / wall mounted cubical l.t motor control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – proper distribution 100 amp copper bus bar 4 pole 1 set micro processor base tpn mccb 100 amp l&t / siemens make with earth fault relay for incoming feeder – 1no. mccb 63 amp tpn type l&t / siemens make for outgoing feeder 2 nos. ( 1no for each pump sets ) suitable size of fully automatic star delta starter make l&t / bch / schnider make 2 nos. 0 500 v voltmeter with selector switch 2nos ct operated ampere meter ( 0 200a ) with ct 2 sets with selector switch 2nos, phase indicating neon lamp 6nos, s.p.p. 2nos doing internal wiring with proper gauge of copper wire etc all complete job and testing on load. 1.09 cost towards supplying, installation, testing and commissioning of tpn main switch / isolator of 100a , make ( havells / schnieder / l&t / any reputed make isi marked. ) . each for pump house no 1 &2. 1.10 cost for supplying and laying of 3.5 core x 50 mm2, pvc insulated and pvc sheathed armoured aluminum cable of 1.1 kv grade. from electric pole to panel with cp and ohc. for pump house no 1 &2. 1.11 socketing of terminal ends with s / f of terminal socket including all labour , tools and tackles. 3.5 core x 50 mm2aluminium cable. 1.12 cost for doing chemical earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 1.13 supplying and laying of 8 swg copper wire for making earthing connection in two from earthing station to panel to motor . 1.14 cost of doing internal electric wiring with s / f of 3 / 20 single core copper cable with s / f of on off switches, indicator, fuses, sockets, switch board, junction boxes, pvc casing, nails & allied fittings etc including supplying and fixing 40 watt led tube light 2 nos, 12w led bulb 2 nos with all fittings etc including electrician charges for raw water pumping plant, clear water pumping plant pump house no 1&2 and outside of pump house etc all complete. 1.15 cost supplying and fixing of 40 watt led flood light with bracket with all fittings and accessories etc all complete for clear water premises. with c.p. & ohc. [ make havells / syska / mescab / bajaj / any reputed make. ] 2 supplying, installation, testing and commissioning of 2 set of new 175 hp vt pump sets and its allied work at raw water pumping plant , multi panchayat rural water supply scheme madhuban pirtand 2.01 supplying, installation, testing and commissioning of water lubricated vertical turbine pump [ make: kirloskar / mather & platt / jyoti / wpil ] capable of discharging 45 lps raw water against a total head of 185 meter at speed not more than 1500 rpm as per is: 1710 / 1989 with column length not less than 50 ft in 5ft each with closed type ss impeller, ss line shaft, ss shaft sleeves, flanged type ms column pipes suitable for below the floor installation and existing delivery header coupled with vertical hollow shaft operated on 415v±10%, 3 phase, ac, 50±5%hz, 4 pole, duty s1, insulation f, lt squirrel cage induction motor with suitable size of coupling as per latest is specification [ make: abb / bhel / crompton / marathon / jyoti / kirloskar ] having 10% more bhp than the pump, making alignment, making electrical connections, with all required tools, tackles, consumables as required, testing and commissioning on full load as per the direction of e / i. etc all complete. 2.02 cost towards dismantling, lifting of old 175 hp pump sets with all 200 mm dia column pipes from intake well and lowering new pump sets with all accessories along with all labour tools and tackles etc all complete. 2.03 cost towards breaking of old pcc foundation and removing of all garbage from pump house to outside with lead of 300 m with all labour tools and tackles etc all complete. 2.04 cost towards making of new pcc foundation sizing 3 x 3 x 1 with supplying and fitting of foundation bolt 4nos., cement, sand , stone chips, as required and plastering and punning over exposed surface etc with materials, all labour tools and tackles etc all complete. 2.05 cost towards supply and laying of 3c x 95 sq. mm copper cable, pvc insulated & pvc sheathed, 1100v grade, isi marked, make.havells / polycab / finolex / gemscab / any reputed make for 3 pump sets. 2.06 socketing of terminal ends with s / f of terminal socket including all labour , tools and tackles. 3 core x 95mm2, copper cable 12 ends. 2.07 providing floor mounted cubical l.t motor control panel fabricated with ms sheet and painted, dust and vermin proof, proper ventilated, consisting of – ( a ) incoming: ( i ) proper distribution 800 amp copper bus bar 4 pole 1 set ( ii ) mccb 800 amp. acb, make l&t / siemens for incoming feeder 1no. ( iii ) 0 500 v voltmeter 1no. with selector switch 1 no, ct operated ampere meter ( 0 500a ) 1no. selector switch 1 no, phase indicating neon lamp 3 nos. b ) outgoing: i ) mccb 630 amp. tpn type, make l&t / siemens for outgoing feeder 3 nos. ( 01 no for each pump set ) ii ) suitable size of fasd starter l&t / bch / schneider make 3 nos. iii ) 0 500 v voltmeter 3nos. with selector switch 3 nos, ct operated ampere meter ( 0 500a ) 3nos. selector switch 3 nos, phase indicating neon lamp 9 nos, single phase preventor 3 nos., doing internal wiring with proper gauge of copper wire etc all complete job with testing on full load. 2.08 cost towards supplying and fixing 5 ton capacity, triple spur gear type chain pulley block suitable for capacity as below with 6 meter lift complete with load chain and hand chain suitable for above lift , tested to 50% over load as per is 3832 carrying isi mark with travelling trolley etc. 3 repairing and overhauling of motor control panels, pump sets and its allied works at clear water pumping plant at maithan ( 14.5mld wtp ) of dhanbad urban water supply scheme phase ii 3.01 cost towards repairing and complete overhauling of motor control panel with all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wire connection inside panel. cleaning, checking, rectifying of faults with supply and fitting of contacter set ( 3tf56 1no and 3tf53 2no. ) seimens make or equivalent capacity of isi marked reputed make, over load relay 1no., transformer oil 30 liter, changing of ampere meter, voltmeter, indicating lamps etc all complete work, dressing and doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . 3.02 cost towards repairing and overhauling of 150hp centrifugal pump and changing of its damaged parts such as pump shaft of en9 materials 1no., ss gland bush 2nos., neckring bush 2nos., checknut 2nos., bearing housing of c.i. materials 2nos. as per sample, supply and fitting of ball bearing skf make 6311 2nos. etc with all labour, tools and tackles, transporting etc all complete. ( rate after deducting the cost of scrap materials ) . 3.03 cost towards overhauling and repairing of 150hp, 3phase induction motor operated on 415v, 50hz, with dismantling of motor, heating, varnishing, supplying and fitting of lead bit having 4 nos hole including supply and fitting of brass nut bolt of 24mm in length with suitable dia for both ends terminal ( motor joint box end & mcp end ) for 150hp motor, supply and fitting of skf make 6319 ball bearing 2nos. etc all complete assembly of the motor and testing on load with all labour, tools and tackles, transporting etc all complete. ( rate after deducting the cost of scrap materials ) . 3.04 cost towards supply and laying of 3 c x 120 sq. mm copper, xlpe unarmoured cable, 1100v grade, from starter panel to motor for 4nos. motor. [ make polycab / finolex / havells / kei / gemscab / any reputed make ] with c.p and ohc etc. [ jsor dwsd 2021 146 m1062 6 ] 3.05 cost towards making cable mouth for above cable with s / f of lugs, pvc tape etc including all labour, tools, tackle and technician charges etc all complete 3.06 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary with cover plate having locking arrangements and watering pipe 2.7 meter long etc with charcoal / coke and salt as required for chemical earthing. 3.07 supplying and laying of 8 swg copper wire for making earthing connection in to from earthing station to panel to motor . 3.08 cost towards supplying, installation, testing and commissioning of 40 watt semi integrated solar street light luminary including battery inside, g.i. pole 6mtrs, structure, arms , nut & bolts etc, suitable spv modules, 2.5 sq. mm x 2 core wire for connection with all labours, tools and tackles etc all complete. [ make havells / exide / any isi marked reputed make ] with cp & ohc. 3.09 cost towards supplying and laying of 2c x 2.5 sq. mm, pvc insulated and pvc round sheathed, copper conductor ( flexible ) industrial cable, 1100 volt, isi marked for common line for all 20nos. flood light as above. [ make havells / polycab / finolex / rr ] with cp & ohc. 4 renovation with supply installation testing and commissioning of pump set, overhauling of motor control panel and its allied work at rural water supply scheme, chirkunda kumardhubi, maithan ( old scheme ) 4. ( a ) raw water pumping plant : 4.01 cost towards supplying, installation, testing and commissioning of electrically driven horizontal split casing centrifugal pump set make ( kirloskar / wpil / mather & plate / jyoti ) coupled with tefc sq. cage induction motor make ( kirloskar / crompton / jyoti / abb ) operated on 415 + 10% volts, 50hz, 1470 rpm mounted on common m.s. fabricated base plate with suitable size of cidf sluice valve 1 no, cidf nr valve 1 no, foot valve 1 no, pressure gauge 1 no, tyre coupling 1 no etc all complete. head 50 m discharge 275 m3 / h ( hp 100 approx ) 4.02 supplying all labour tools and tackles for taking out old and damaged c / f pump set with all accessories , demolition of foundation for installation of new hsc centrifugal pump sets. 4.03 supplying all labour tools and tackles for making new pcc foundtiaon of size 6′ x 3 x 3′ with all materials such as cement , sand, stone chips, foundation bolt 6nos etc all complete and plastering and punning over exposed surface with all labour, tools, tackle and technician charges. 4.04 cost towards supply and laying of suction pipe line with s / f of 10 dia g.i. pipe 2 meter, 10 dia g.i. bend 1 no., 10dia g.i. flange 4nos., rubber insertion 10kg, nut, bolt & washer 10kg etc and cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) 4.05 cost towards supply and laying of 8dia delivery line with s / f of 8 dia heavy duty g.i. pipe 1 meter, 8dia g.i. flange 4nos., rubber insertion 10kg, nut, bolt & washer 10kg etc and cutting of pipe in required size and doing complete welding work including all labour, tools, tackle and technician charges.with cp & ohc. ( rate after deducting the scrap materials. ) 4.06 cost towards overhauling of motor control panel with all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wire connection inside panel. cleaning, checking, rectifying of faults with supply and fitting of damaged spares such as bus bar 1set, ampere meter 1no., voltmeter 1no., indicating lamps 3 no. etc, dressing of motor cables with new lugs, crimping works etc all complete and testing on full load. ( rate after deducting the cost of scrap materials ) . 4.07 cost towards overhauling of f.a.s.d. starter panel with all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wire connection inside panel. cleaning, checking, rectifying of faults with supply and fitting of contacter set ( ml 4 1no and ml 6 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work, dressing and doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . 4.08 cost towards supplying and fitting of 40w led flood light, with bracket, copper wire, on off switch etc with all accessories including all labour tools , tackles and technician charges., with cp & ohc, ( rate after deducting the scrap materials. ) . make havells / syska / mescab / polycab / phillips 4.09 providing chipping work on the roof surface of raw water pump house, removing of all garbage to outside with lead of 50 m , providing and cleaning of concrete surface to remove dust and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. pounding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. on identification of seepage, cement grouting to be done with non shrink expanding admixture of sika lndia pvt.ltd. / myk schomberg / dr fixit / fosroc or equivalent. [ size 12.5 m x 6.7 m = 83.75 m2 ] 4.10 cost towards providing pcc m 200 in nominal mix of 1:1.5:3 on roof with approved quality of stone chips 12mm to 6mm size graded and clean course sand of fm 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of e / i. [ size 12.5 m x 6.7 m x 0.05 m= 4.19 m3 ] 4.11 providing 12 mm thick water proof cement plaster ( 1:3 ) with clean coarse sand of f m. 1.5 with integral water proofing compound liquid @125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i. brand fosroc conplast x421 lc, sika plastocrate plus, dr fixit pidiproof lw+, myk proof wp 10 or equivalent. [ size 12.5 m x 6.7 m = 83.75 m2 ] 4.12 dismantling old plaster and pointing in cement or lime and taking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of e / i. inside and outside of pump house, approx=280m2 4.13 providing 6mm thick cement plaster ( 1:4 ) in ceiling and wall of building with clean coarse sand of f.m. 15 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i. 4.14 providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls , scaffolding, curing and taxes all complete as per building specification and direction of e / i. 4.15 providing 2 ( two ) coats of synthetic enamel paint of approved shade & make over steel surface including cleaning the surface, removing dirt, scales, smokes, grease, scaffolding & taxes all complete as per building specification and direction of e / i. for door, window, common header pipe, valves etc. approx 20m2 ( b ) clear water pumping plant : 4.01 cost towards supplying and fitting of complete rotating assembly for 50hp centrifugal pump, having head 65m discharge 113.5 m3 / hr make kirloskar with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) 4.02 cost towards supplying and fitting of complete rotating assembly for 50hp centrifugal pump, having head 70 m discharge 114 m3 / hr make wpil with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) 4.03 cost towards supplying and fitting of complete rotating assembly for 60hp centrifugal pump, having head 70 m discharge 160 m3 / hr make mather & platt with ss pump shaft, c.i. impeller, ss sleeve, bushes, gland tightener 2nos., ball bearing etc all complete with machining as per size and sample, assembling and fitting on the base plate, with all labour tools tackles and technician charges. ( rate after deducting the scrap materials. ) 4.04 cost towards supply and fitting of 4dia coupling set for 50hp pump set with nut bolt etc all complete. 4.05 cost towards supply and fitting of 4dia coupling set for 60hp pump set with nut bolt etc all complete. 4.06 supplying, fitting, installation, erecting and commissioning of approved make h.t. outdoor type gang operated air break triple pole switch, suitable for 11kv line, rotating type, with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps including cp, ohc , transportation, labour charges etc. ( rate after deducting the scrap materials. ) 4.07 cost towards supplying and fitting of 250a mccb, 3phase, 50hz, isi marked, with all labour tools , tackles and technician charges. with cp & ohc, ( rate after deducting the scrap materials. ) . make l&t / abb / hpl / cg 4.08 cost towards supplying and fitting of 160a mccb, 3phase, 50hz, isi marked, with all labour tools , tackles and technician charges. with cp & ohc, ( rate after deducting the scrap materials. ) . make l&t / abb / hpl / cg 4.09 cost towards overhauling of motor control panel cum 3 nos. of f.a.s.d. starter panel with all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wire connection inside panel. cleaning, checking, rectifying of faults of 3nos. f.a.s.d. starter with supply and fitting of contacter set ( mnx95 1no and mnx50 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work each for 3 nos. fasd starter, dressing and doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . for mcp no. 1. 4.10 cost towards overhauling of motor control panel cum 2 nos. of f.a.s.d. starter panel with all labour tool, tackles and technician charges for disconnecting the electric line & opening of electric wire connection inside panel. cleaning, checking, rectifying of faults of 2nos. f.a.s.d. starter with supply and fitting of contacter set ( mnx70 1no and mnx50 1no. ) l&t make or equivalent capacity of isi marked reputed make, over load relay 1no., timer 1no., spp 1no. etc all complete work each for 2 nos. fasd starter, dressing and doing fresh electric connection with new wire and connector inside panel, rechecking of all connections and testing on full load. ( rate after deducting the cost of scrap materials ) . for mcp no. 2. 4.11 cost towards supplying and fitting of 40w led flood light, with bracket, copper wire, on off switch etc with all accessories including all labour tools , tackles and technician charges., with cp & ohc, ( rate after deducting the scrap materials. ) . make havells / syska / mescab / polycab / phillips 4.12 providing chipping work on the roof surface of clear water pump house, removing of all garbage to outside with lead of 50 m , providing and cleaning of concrete surface to remove dust and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. pounding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. on identification of seepage, cement grouting to be done with non shrink expanding admixture of sika lndia pvt.ltd. / myk schomberg / dr fixit / fosroc or equivalent. 4.13 cost towards providing pcc m 200 in nominal mix of 1:1.5:3 on roof with approved quality of stone chips 12mm to 6mm size graded and clean course sand of fm 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of e / i. 4.14 providing 12 mm thick water proof cement plaster ( 1:3 ) with clean coarse sand of f m. 1.5 with integral water proofing compound liquid @125 ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i. brand fosroc conplast x421 lc, sika plastocrate plus, dr fixit pidiproof lw+, myk proof wp 10 or equivalent. 4.15 dismantling old plaster and pointing in cement or lime and taking out joints to 15mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of e / i. inside and outside of pump house, 4.16 providing 6mm thick cement plaster ( 1:4 ) in ceiling and wall of building with clean coarse sand of f.m. 15 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of e / i. 4.17 providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls , scaffolding, curing and taxes all complete as per building specification and direction of e / i. 4.18 providing 2 ( two ) coats of synthetic enamel paint of approved shade & make over steel surface including cleaning the surface, removing dirt, scales, smokes, grease, scaffolding & taxes all complete as per building specification and direction of e / i. for door, window, common header pipe, valves etc....

East Central Railway - Jharkhand

32477953 supply of manufacture, testing and supply of dischargingmanufacture, testing and supply of discharging,manufacture, testing and supply of discharging load box for nickel cadmium battery as per following 1. resistance material nickel chromium alloy. 2. rating 110v, 60amps. 3. on load variation tap for 20,10, 5 and 2 amps respectively. 4. maximum permissible temperature 300 deg c 5. cooling forced. 6. enclosure set of resistance housed in ms structure with ammeter & voltmeter to monitor load current & voltage....

Drinking Water And Sanitation Department - Jharkhand

32472818 e quotation for repairing and rewinding of 5 h.p motor for govt. building w/s golmuri p/p e quotation for repairing and rewinding of 5 h.p motor for govt. building w/s golmuri p/p , cost towards dismantling of the 5 h.p kirloskar motorfrom foundation and taken out rotor from stator etc. all complete , cost towards complete stator rewinding of 5 h.p sq. cage induction motor 3 phase 50 c/s, 1440 rpm with super enameled copper wirealong with all requiredmaterials, such as sleeves tape, cotton tape, glass tape etc. includingvarnishingheating all complete.(after the deductioncost of scrap materials) , cost towards straightening of the pump shaft and remetaling with machining, turning and finishing all complete. , cost towards supplying and fittingballbearing 2306 and proper greasing all complete. , cost towards making s/f g.m neck ring as per size and sample 5 h.p. c/f pump set. , cost towards making s/f, g.m bush as per size andsample 5 h.p. c/f pump set. , supplying and fixing 63 amp. 415± 15% voltage change over switch, havells / l & t make , supplying and fitting cubical type duly painted control panel boardconsisting 32 amps. tpn mccb inbuilt single phase preventor and suitable forstar delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meterwith selector switch make l&t / havell;s , chemical earthing3 metersand80 mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangement including soldering, riveting, jointing g.i flat 50 mm x 6 mm to all equipments. ( for p/set no. 01 & 02) , cost towards supplying and fitting150w street light with all complete fitting such ascomplete cover with glass / fiber fitting with suitable cable nut, bolt etc all complete. make philips / bajaj /any reputed make...

South Eastern Railways - Jharkhand

32439414 supply of meter calibration unitmeter calibration unit, meter calibration unit as per technical specification mentioned below ( 1 ) kv meter ( aux. line voltmeter ) , range ( 0 600v ac ) & ( 0 35kv ) , 3 1 / 2 dpm, disply range: 600v ac, resolution : 1v ac ( 2 ) line voltmeter ( traction motor voltmeter ) , range ( 0 1.8kv dc or 0 900v dc ) , 3 1 / 2 dpm, display range: 0 2000v dc, resolution: 1v ( 3 ) ammeter ( traction motor ammeter ) , range ( 1500a 0 1500a ) , changeover / toggle switch for + / current simulation, 3 1 / 2 dpm, display range 2000a, resolution: 1a ( 4 ) uba meter ( battery voltmeter ) , range ( 0 150v dc ) , 3 1 / 2 dpm, display range: 200v, resolution:0.1v ( 5 ) traction / braking effort meter bogie, range ( 100te 0 100be ) , fs: 10v dc 0 10 v dc, 3 1 / 2 dpm, display range: 200, resolution: 1 unit ( 6 ) catenary voltmeter, range 0 30 kv, fs: 10v dc, 3 1 / 2 dpm, display range: 30kv, resolution:0. 1 kv...

Department Of Technical Education - Jharkhand

32317733 bids are invited for sextant measuring tape , young s modulus , 3 1 2digit digital multimeter manual range , carrey foster bridge with four gap complete setup , norton s theorem with bakelite panel and round meters , thevenin s theorem with bakelite panel and round meters , pn zener diode led characteristics apparatus , thermo electric , to determine the refractive index of the material of a prism using sodium light , determine the wave length of sodium lamp by newton ring method , universal b.h curve apparatus , zener diode , fet characteristics apparatus with aluminum panel and square meters , mosfet characteristics apparatus with aluminum panel and square meters , amplitude modulation and demodulation , operational amplifier as inverting, non inverting, unity gain amplifier and frequency response with analog voltmeter , operational amplifier as differentiator and integrator , determine of the specific rotation of the cane sugar solution with the help of polarimeter , boltzman constant apparatus with pn junction diode with aluminum panel and digital panel meters , to determine 1 wavelength he ne laser using plane diffraction grating. complete set , strain gauge trainer kit with cantilever beam , molecular atomic models , magnetic stirrer with hot plate , rotary flask shaker , variable volume micropipette , analytical balance , double beam uvvis spectrophotometer , benzaldehyde 500ml , aniline 500ml , ethyl alcohlal 500ml , acetone 500ml , benzoic acid 500gm , benzene 500ml , phosphoric acid 500ml , barium diphenylamine sulphonate ar 25gm , hydrogen fluoried 500gm , digital tds meter labtronics , dissolved oxygen meter , dissolved turbidity meter , maximum minimum therme meter , ph meter , phytoplankton net mesh size 10, 25, 50, 100 , plankton counting cell sedwich rafter , secchi disk , haemocytometer , insect box...

Department Of Labor And Employment - Jharkhand

32295197 bids are invited for measuring steel tape , combination plier insulated , screw driver insulated , electrician screw driver , heavy duty screw driver , electrician screw drive , punch centre , knife double bladed , neon tester , steel rule graduated , hammer cross peen , pipe vice cast iron , hand vice , table vice , hacksaw frame , file flat , file half round , file round , pliers long nose , pliers flat nose , pliers round nose insulated , de metric spanner double ended , wire gauge , portable electric drill machine , crimping tool , pliers side cutting , wire stripper , hammer ball peen with hndandle , scriber , tool kit box or bag , allen key , scissors blade , torque wrench , pipe cutter to cut pipes , try square , multi meter analog , load bank , wire cutter and stripper , earth plate , earth electrode , out side micrometer , tap set , trolley for transportation of batteries , die for threading , electrical wiring and switch gear rack , protective relays and contactors rack , mccb , elcb and rccb , plumbing tools , multimeter digital , megger , hydrometer , solar insulation meter , pyranometer , pyrheliometer , lux meter , magnetic flux meter , tong tester or clamp meter , soldering iron , temperature controlled soldering iron , thermometer digital , sun shine recorder , magnetic compass , cut models of photo voltaic cell assembly , cut model of lead acid battery , solar simulator , curve tester , sun path finder , solar energy trainer , solar tracker demonstrator kit , halogen lamp , motorized bench grinder , battery charger , solar photovoltaic module , solar panels , solar charge , solar charge , array junction box , solar lantern , solar lantern assembly sets , home light system , solar cell kit , clinometer , spirit level , anemometer , dc table fan , ac voltmeter , volt meter , ammeter mc , ammeter mc centre zero , power factor meter , rheostat , ac energy meter , kilo wattmeter analog , digital wattmeter , phase sequence indicator , frequency meter , dc led lamp , dc pump , pwm controller , mppt charge controller , solar pcu , solar grid tied inverter demonstrator kit , solar street light , solar wind and hybrid power plant , solar traffic light , used water treatment solar plant demonstrator kit , demonstration kit for wind generation , rubber gloves , cotton gloves , gum boots , safety goggles , safety helmet , first aid kit , fire extinguisher , fire buckets , working bench , wiring board , white board...

Department Of Atomic Energy - Jharkhand

32291292 bids are invited for earth leakage relay , ammeter , voltmeter , contactor , no volt coil for 300a contactor , ct operated thermal over load relay , i s pilot panel intrinsically safe , heavy dutyscrew assembly for plug and socket , inter lock assembly ,circlip for plug and socket , auxiliary contactor , pilot relay total quantity : 407...

Jharkhand State Building Construction Corporation Limited - Jharkhand

32287667 niq for minority residential niq for minority residential school margo munda, deoghar , phartiha, garhwa district. barhate, sahebganj district name of work : .(3.) construction of school with residential building for minority community at margo munda, deoghar district.(4.) construction of school with residential building for minority community at phartiha, garhwa district.(6)proposed construction of residential school for minority group at barhate, sahibganj, jharkhand mr fabrication, supplying, installation, testing & commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 v, 3 phase 50 hz ac supply with enclosure protection class ip 42. for terrace pump mr fabrication, supplying, installation, testing & commissioning of electrical control panel of cubical construction, wall mounted type, fabricated out of 2mm. thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection, and accessories mounting and internal wiring, earth terminals, numbering etc. complete in all respects, suitable for operation on 415 v, 3 phase 50 hz ac supply with enclosure protection class ip 42. for terrace pump mr supplying fitting fixing pressure gauge assemble with gate/ball valve all complete with labor and material as per engineer in charge. mr supplying fitting fixing air release valve / drain valve all complete with labor and material as per engineer in charge. mr supplying fitting fixing ms structure support for piping all complete with labor and material as per engineer in charge. mr supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick m.s. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect. mr providing , fixing dry chemical powder (stored pressure type) mono ammonium phosphate 50% powder confirming to ‘is 14609’ , nitrogen pressurized, controllable discharge mechanism, pressure gauge, discharge hose & nozzle epoxy polyester powder coated as per ‘is 15683’ isi mark fire extinguishers. operating temperature: ( ) 20oc to (+) 55oc suitable for ‘a’ ‘b’ ‘c’ class of fire complete in all respects (4 kg capacity) mr stainless steel text (text height 250 mm ) at pergola slab with grouting all complete including matrial & labour as pet e/i mr carbon di oxide type , gas confirming to is ‘15222’ , cylinder confirming to ‘is 7285’ & peso approved ,controllable discharge mechanism, discharge hose & horn as per ‘is 15683’ & ‘is 2878’ isi mark fire extinguishers (wheel type or squeeze grip type). operating temperature : ( )20oc to (+)55oc suitable for ‘b’ ‘c’ class of fire (4.5 kg capacity) mr providing , fixing modular type fire extinguishers for electrical rooms (stored pressure type) mono ammonium phosphate 50% powder confirming to ‘is 14609’ , nitrogen pressurized, controllable discharge mechanism, pressure gauge, discharge hose & nozzle epoxy polyester powder coated as per ‘is 15683’ isi mark fire extinguishers. operating temperature: ( ) 10oc to (+) 55oc suitable for ‘a’ ‘b’ ‘c’ class of fire complete in all respects (5 kg capacity) mr providing and fixing 25 mm nominal gun metal gate valve class i with ci wheel of approved quality with union (screwed end) mr main lt panel for main building : supplying, designing, manufacturing, installation, testing and commissioning of lt panel of 14 swg crca sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(ip 43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415v, 50hz, 3 ph. ac supply and fault level 50 ka with front operated construction including separate fabrication arrangement for fixing mccbs and bus coupler. the sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 nos. earth studs.the panel includes 415v, 200a, 3ph, 50ka, 50hz electrolytic aluminium bus bar (e91ewp) aluminium, earth bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing feeders complete in all respects. all inter connections shall be made with 2.5 4, 6, 10 sq mm pvc cu. wire. main lt panel for main building : supplying, designing, manufacturing, installation, testing and commissioning of lt panel of 14 swg crca sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(ip 43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415v, 50hz, 3 ph. ac supply and fault level 50 ka with front operated construction including separate fabrication arrangement for fixing mccbs and bus coupler. the sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 nos. earth studs. the panel includes 415v, 200a, 3ph, 50ka, 50hz electrolytic aluminium bus bar (e91ewp) aluminium, earth bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing feeders complete in all respects. all inter connections shall be made with 2.5 4, 6, 10 sq mm pvc cu. wire.all incomer mccb and bus coupler shall be mechanically operated . all 4 pole mccb with thermomagnetic based release must have following character: icu=100% ics with adjustable s/c and o/lprovision for inbuilt earth leakage module & provision for inbuilt measuring unit. the panel consisting of the followings, 4 pole mccb 160 a, 35 ka with fixed thermal magnetic setting 1 no, provision of mechnical interlocking between 125a/fp/25ka mccb as common incoming and 1 no. of 125a on load change over for d.g incomer, in such a way so that the two supplies are not parallel at any time.1 no. 125a tpn on load change over panel mounted open execution type and suitable bus arrangement for cable termination. make l&t/sucomo. 1 no. 125a/fp/16ka/ mccb thermomagnetic release type, and s/c, o/l protection, with rotary handle & spreader links. mcb tpn 40a 10 nos, mcb dp 40a 2nos( oter light+spare), mcb dp 63a 6 nos( pdb+ups+spare),electronic on timer delay 30 sec, 200 amp 415 v heavy duty three phase with neutral busbar chamber, indicator switch 3 nos, selector switch, analog voltmeter 3 nos, analog ameter, c.t. coil mr main lt panel for hostel building : supplying, designing, manufacturing, installation, testing and commissioning of lt panel of 14 swg crca sheet (2 mm) steel , dust and vermin proof with reinforcement of suitable size iron channel , with proper lifting arrangement effecting proper connection of all incomers and outgoing(ip 43) fully compartmentalized cubical type, floor mounted , totally enclosed, extendable on both sides, switch board and suitable for operation on 415v, 50hz, 3 ph. ac supply and fault level 50 ka with front operated construction including separate fabrication arrangement for fixing mccbs and bus coupler. the sheet steel under go minimum 7 tanks treatment followed by finishing powder coating of minimum 60 micron thickness duly compartmentalized having accessories mounted inside the cubical panel, earthing with 2 nos. earth studs. the panel includes 415v, 200a, 3ph, 50ka, 50hz electrolytic aluminium bus bar (e91ewp) aluminium, earth bus for main supply, removable glands plates, cable glands and sending and receiving ends, including connection with outgoing feeders complete in all respects. all inter connections shall be made with 2.5 4, 6, 10 sq mm pvc cu. wire.all incomer mccb and bus coupler shall be mechanically operated . all 4 pole mccb with thermomagnetic based release must have following character: icu=100% ics with adjustable s/c and o/lprovision for inbuilt earth leakage module & provision for inbuilt measuring unit. the panel consisting of the followings 4 pole mccb 160 a, 35 ka with fixed thermal magnetic setting 1 no 1 no. 125a tpn on load change over panel mounted open execution type and suitable bus arrangement for cable termination. make l&t/sucomo. 1 no. 125a/fp/16ka/ mccb thermomagnetic release type, and s/c, o/l protection, with rotary handle & spreader links. mcb tpn 40a 10 nos, mcb dp 40a 6nos( outer light+spare) , mcb dp 63a 4 nos( ups+spare), electronic on timer delay 30 sec , 200 amp 415 v heavy duty three phase with neutral busbar chamber , indicator switch 3 nos , selector switch, analog voltmeter 3 nos, analog ameter, c.t coil mr sitc of 24x ports 10/100/1000base t ports,4x 1g sfp ports, supports poe standards ieee 802.3af, 802.3at,1x usb c console port,1x usb,up to 370 w of class 4 poe power, fanless design, with dual core arm cortex a9 @ 1016 mhz cpu, memory 4 gb ddr3 16 gb emmc , packet buffer size of 12.38mb (4.5mb ingress/7.875mb egress),ipv6 ready certified mac address table size: 16000 entries;average latency 1 gbps latency: < 1.5 µs (lifo 64 byte packets), throughput: up to 41.6 mpps (64 byte packets), switching capacity: 56 gbps, operating temperature 32°f to 113°f (0°c to 45°c) up to 5000 ft (1.5 km), certifications ul,en,fcci, preferred make hp/aruba/allied telesis/cisco/netgear or as approved by e/i mr sitc of 12x ports 10/100/1000base t ports,2x 1g sfp ports,2x 1gbe ports , supports poe standards ieee 802.3af, 802.3at,1x usb c console port,1x usb,up to 139w of class 4 poe power, fanless design,with dual core arm cortex a9 @ 1016 mhz cpu, memory 4 gb ddr3 16 gb emmc , packet buffer size of 12.38mb (4.5mb ingress/7.875mb egress),ipv6 ready certified mac address table size: 16000 entries;average latency 1 gbps latency: < 1.5 µs (lifo 64 byte packets), throughput: up to 23.8 mpps (64 byte packets), switching capacity: 32 gbps, operating temperature 32°f to 113°f (0°c to 45°c) up to 5000 ft (1.5 km), certifications ul,en,fcci, preferred make hp/aruba/allied telesis/cisco/netgear or as approved by e/i mr sitc of 24 port utp jack panel (24 port rj 45 loaded cat 6 utp 19 rackmountable patch panel preferbaly with 6 blocks). (make:legrand/panduit/rit/siemon) detailed specs for 19 1u 24 port unsheilded, patch panel patch panel should be modular design, populates up to 24 utp keystone type jacks in 1u, patch panel should be enhanced with cable strain relief with retention tray; it should be single metal both front panel and rear tray, material: sub rack made of ms steel with dimension 44.4 mm : 482.6 mm : 105 mm (h:w:d) tray, information outlet or connectin module should comply with the specification mentioned above in 2, standard : conforms to iec 60603 7 (603 7) for keystone type, snap on apertures, should be rohs complied mr sitc of straight lan patch chord 1 mtr (make:legrand/panduit/rit/siemon) ,detailed specs for patch cord, u/utp 4p, cat.6, length  1/3 metre, standardization: compliant with cat.6, class e requirements: iso/iec 11801 2nd edition compliant with cat.6 component standards iec 60603 7 4 and 60603 7 5 , cable shield:  u/utp, number of conductors : 8 , stranding: 7 x 0.20 mm (24 awg), cable jacket characteristics: cable, metal free cable overall diameter: 6.5±0.2 mm, tube / wire type: stranded conductor, insulation: solid polyolefin, 0.97±0.02 mm diameter ,plug: feature cable retension, with enhanced pull strength., cat 6 patch cord plug to have round cable holder and strain relief boot to avoid bending. jacket: pvc with 8 different color options,plug should have high repeatability cross talk performance mr sitc of fully loaded 9u 19 600*500 wall mounted rack with all required accessories 2 nos. of fan,6a 6 plug pdu 1 nos. ,cable manager 2 nos., mounting screws 20 pcs ; preffered make legrand/apw/president/valrack/netrack mr sitc of epabx system: ip based 100% non blocking epabx system should be a ip compatible with rich feature set of the system and can be connected with pure voice over ip (voip) communication network across corporate local and wide area networks (lan and wan) as & when required. central processing unit: the system main software should be open architecture based. the cpu of main system shall be 32 bit processor working at 2.0 ghz or better. the system should be wall mountable. • system architecture should be latest pure ip and should be wall mountable; meet me conference 30 party x 2 from day 1 must be available. must support unified communications equipped with 16 analog extensions expandable upto 48 extensions,4 analog trunk ports,epabx make: avaya/nec/unify mr analog basic push button telephone: sitc of analog telephone make: panasonic/ bpl/beetel mr sitc of telephone tag block): ip 65( weather proof). preffered make krone 50 pair krone box fully loaded without ipm mr supply, fitting, fixing, commissioning and testing of 16 sq. mm copper conductor multi strand pvc sheilded frls wire with suitable copper lugs for battery interconnection and suitable 16 sq. mm copper wire of 2 length of 10 mtrs each for ups to battery excluding cable from panel to ups and ups to panel. make polycab/havells/kei mr chemical earthing: supply, errection, fitting, fixing, commissioning and testing along with earth cutting, digging, earth refilling for chemical earthing of the building except g.i. strips (25mmx5mm) each earth pit has to be tested with earth tester 1000 v/1000 ohms & the test report has to be submitted by the contractor to the department after certification of the same by the consultant. the above chemical earthing includes the provision of masonary enclosure and hdpe earth pit cover 300mm x 300 mm (under floor earth inspection pit) having locking arrangement as earth chamber.the above chemical earthing includes the following items (3 mtr earthing) ; each chemical earthing shall have following details: supply of pollution free earthcon compound 4 bags of 25 kg each ; supply of 17.2 mm dia, 250 micron,molecularly bounded copper coated 3 mtr long electrode. tested as per iec 62561 2. meets the requirement of is 3043 & iec 60364 5 54. tested for short circuit withstanding capacity. high tensile strength. (ul listed).; supply of stainless steel u bolt clamp; supply of hdpe earth pit cover for earth chamber (capacity of 5 ton) ; sub total c( ups system & accessories) mr sitc of 5mp fixed lens network bullet camera with following technical specifications; preffered make: honeywell/bosch/hikvision/pelco/sony image sensor : 1/2.7 progressive scan cmos, min. illumination : color: 0.003 lux @ (f1.4, agc on), b/w: 0 lux with ir preferred recording resolution: 5mp (2592x1944) or better ,day & night: ir cut filter , shutter speed: 1/3 s to 1/100,000 s, digital noise reduction; 3d dnr ,wdr: 120db true wdr or better, lens; 4mm , ir range : 40m ir or higher ,streaming type: should support quad video streams or better ,video compression: h.265,h.264, h.264+,h.265+,mjpeg and main stream supports h.264+/h.265 , audio compression: g.711ulaw/g.711alaw/g.722.1/g.726/mp2l2/pcm/mp3 , image enhancement: blc, hlc, 3d dnr, eis, defog,roi , (5 fixed regions for main stream and sub stream). image settings: rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser , day/night switch: day, night, auto, schedule , network protocol : tcp/ip, icmp, http, https, ftp, dhcp, dns, ddns, rtp, rtsp, ntp, upnp, smtp, igmp, 802.1x, qos, ipv4, ipv6, udp, bonjour, ssl/tls, pppoe, arp, snmp,open network video interface (profile s, profile g, profile t),isapi. simultaneous live view: 6 channeluser host: 32 users. 3 user levels: administrator, operator and usersecurity: password protection, complicated password, https encryption, ip address filter, security audit log, basic and digest authentication for http/https, tls 1.2, wsse and digest authentication for open network video interface, memory card encryption.edge base recording storage: built in memory card slot, support microsd card, up to 256 gb ,preferable analytics features: motion detection, video tampering alarm, line crossing detection, intrusion detection,scene change detection, video quality diagnosis.event alarm: notify surveillance center, trigger recording, trigger capture, send email, audible warning,network disconnected, illegal login.ethernet port: 1 x rj45 10m/100m ethernet port, audio interface; 1x input, 1x output , power supply: dc12v, poe (802.3af) , operating conditions: 30° c ~ + 60° c ingress protection: ip67 , certifications: ce, fcc, ul,bis. mr sitc of 32 channel nvr processor : dual core embedded processor, operating system : pre loaded licensed os,ip camera support up to 32 ch , should support h.265+/h.265/h.264+/h.264 video formats, up to 2 ch @ 8mp or 4 ch @ 4mp or 8 ch @ 1080p decoding capacity,1 hdmi and 1 vga interfaces: both interfaces support independent video output,4 hdds for continuous video recording, up to 256 mbps incoming bandwidth, outgoing bandwidth 160 mbps, audio output 1 ch, rca (2.0 vp p, 1 kω, using the audio input ),two way audio 1 ch, rca (2.0 vp p, 1 kω, using the audio input ),video output mode hdmi/vga independent output, recording resolution 12 mp/8 mp/6 mp/5 mp/4 mp/3 mp/1080p/uxga/ 720p/vga/4cif/dcif/2cif/cif/qcif,sata 4 sata interfaces of capacity up to 10tb capacity for each hdd, serial interface 2 rs 485 (half duplex), 1 rs 232, usb interface front panel: 2 × usb 2.0; rear panel: 1 × usb 3.0, smart phone connectivity through app or browser : iphone, ipad, android, windows phone, should support multiple vca (video content analytics) events, configurable special camera smart functions, such as vca detection (motion, line crossing, intrusion, etc.), heat map, anpr, and people counting power sitc : ac 100v~240v, 50/60hz,regulatory : ce, fcc,ul and rohs; preferred make: honeywell/bosch/hikvision/pelco/sony mr sitc of 16 channel nvr processor : dual core embedded processor, operating system : pre loaded licensed os,ip camera support up to 16 ch , should support h.265+/h.265/h.264+/h.264 video formats, up to 2 ch @ 8mp or 4 ch @ 4mp or 8 ch @ 1080p decoding capacity,1 hdmi and 1 vga interfaces: both interfaces support independent video output,4 hdds for continuous video recording, up to 256 mbps incoming bandwidth, outgoing bandwidth 160 mbps, audio output 1 ch, rca (2.0 vp p, 1 kω, using the audio input ),two way audio 1 ch, rca (2.0 vp p, 1 kω, using the audio input ),video output mode hdmi/vga independent output, recording resolution 12 mp/8 mp/6 mp/5 mp/4 mp/3 mp/1080p/uxga/ 720p/vga/4cif/dcif/2cif/cif/qcif,sata 4 sata interfaces of capacity up to 10tb capacity for each hdd, serial interface 2 rs 485 (half duplex), 1 rs 232, usb interface front panel: 2 × usb 2.0; rear panel: 1 × usb 3.0, smart phone connectivity through app or browser : iphone, ipad, android, windows phone, should support multiple vca (video content analytics) events, configurable special camera smart functions, such as vca detection (motion, line crossing, intrusion, etc.), heat map, anpr, and people counting power sitc : ac 100v~240v, 50/60hz,regulatory : ce, fcc,ul and rohs; preferred make: honeywell/bosch/hikvision/pelco/sony mr sitc of 6tb surveillance grade hard disk for nvr for 30 days back up; make seagate/wd mr 43 4k led panel,preffered make lg/samsung/panasonic mr supplying and fixing of hose cabinet of size 450mm x 450mm x 250mm made of 2mm thick m.s. sheet with 6mm thick glazed glass door including necessary locking arrangment suitable to accomodate 1 nos. 15 mtr. long hose pipe, 1 no. branch pipe mounted on wall or raised brick platform and duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect. ...

East Central Railway - Jharkhand

32193448 supply of catenary voltmeter,range 15.5kv 25.9 kv specification : clw spec.no. clw/es/3/0070catenary voltmeter,range 15.5kv 25.9 kv specification : clw spec.no. clw/es/3/0070,catenary voltmeter,range 15.5kv 25.9 kv specification : clw spec.no. clw/es/3/0070 csd/trs/mgs , ecr uttar pradesh 16.00 numbers...

Jharkhand State Electricity Board - Jharkhand

31955758 rate of materials supply of materials ( i ) rail pole 60 kgs 13 meter ( ii ) rail pole 52 kgs 13 meter ( iii ) rs joist pole 9.3 meter ( 175x85mm ) 19.6 kgs per mtr ( iv ) rs joist pole 9 meter ( 116x100mm ) 23 kgs per mtr ( v ) 125x70x5 rs gi joist 8mtr ( 13.3kg / mtr ) ( vi ) wpb 160x160, 30.4kg / m weather resistant h beam, 11m ( vii ) wpb 160x160, 30.4kg / m weather resistant h beam, 13m ( viii ) psc pole 400 kg w.l ( 9 mtr. ) ( ix ) psc pole 200 kg w.l ( 8 mtr. ) ( x ) steel tubular pole ( sp 32 ) of 9 meter ( xi ) steel tubular pole ( sp 55 ) of 11 meter ( xii ) steel tubular pole ( sp 72 ) of 13meter acsr conductors ( i ) acsr panther conductor ( 232 sq. mm ) ( ii ) acsr wolf conductor ( 150 sq. mm ) ( iii ) acsr dog conductor ( 100 sq. mm ) ( iv ) acsr racoon conductor ( 80 sq. mm ) ( v ) acsr rabbit conductor ( 55 mm2 ) ( vi ) acsr weasel conductor ( 34 sq. mm ) insulators & h / w fittings ( i ) 33 kv pin insulator 10 kn with pin ( porcelain type ) ( ii ) 33 kv polymer pin insulators 10 kn with gi pin and nut & washer ( iii ) 33 kv disc insulator ( polymer type ) 90 kn with h / w fitting and nut & washer ( iv ) 33 kv disc. insulator ( porcelain type ) 70 kn with h / w fitting ( v ) 33 kv disc insulator ( polymer type ) 70 kn with h / w fitting ( vi ) suspension hardware suitable for panther conductor ( vii ) tension hardware suitable for panther conductor ( viii ) 11 kv pin insulator 10 kn, od 40 mm dia with pin ( polymer type ) and nut & washer ( ix ) 11 kv pin insulator 5kn with pin ( porcelain type ) ( x ) 11 kv pin insulator 5 kn with pin ( polymer type ) and nut & washer ( xi ) 11 kv disc insulator ( polymer type ) 70 kn with h / w ( xii ) 11 kv disc insulator ( porcelain type ) 45 kn with h / w ( xiii ) 11 kv disc insulator ( polymer type ) 45 kn with h / w ( xiv ) lt pin insulator with pin ( porcelain type ) ( xv ) lt pin insulator ( porcelain type ) ( xvi ) lt shackle insulator ( porcelain type ) ( xvii ) lt shackle strip with bolts and nut ( xviii ) 33 kv post insulator 10 kn ( polymer ) ( xix ) 11 kv post insulator 5 kn ( polymer ) ( xx ) 33 kv stay insulator ( xxi ) 11 kv stay insulator ( xxii ) lt stay insulator ( xxiii ) mid span compression joints suitable for acsr panther conductor ( xxiv ) repairing sleeve suitable for acsr panther conductor isolator ( i ) 33 kv isolator 800 amp , 3 phase, with earth switch ( ii ) 33 kv isolator 800 amp , 3 phase, with out earth switch ( iii ) 33 kv isolator 630 amp, 3 phase, without earth switch ( iv ) 33 kv isolator 630 amp, 3 phase, with earth switch ( v ) 33 kv isolator 400 amp, 3 phase, with earth switch ( vi ) 11 kv isolator 630 amp, 3 phase, with earth switch ( vii ) 11 kv isolator 630 amp, 3 phase, without earth switch ( viii ) 11 kv isolator 400 amp, 3 phase, without earth switch ( ix ) 11 kv isolator 400 amp, 3 phase, with earth switch ( x ) 11 kv isolator 200 amp single phase ab switch ( i ) 33 kv 3 pin type, 3 phase, ab switch 800 amp ( porcelain type ) ( ii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( iii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( polymer type ) ( iv ) 11 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( v ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( polymer type ) ( vi ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( porcelain type ) ( vii ) 11kv ab switch 200 amps ( single break ) lightening arrestor ( i ) lightening arrestor ( 9kv 5ka ) line type ( ii ) 11 kv lightening arrester ( 9 kv, 10 ka class ii, station type ) ( 1set=3nos ) ( iii ) 33 kv lightening arrester ( 30kv, 10ka class ii, station type ) ( 1set=3nos ) earthing ( i ) 25mm dia ms rod 3 m long for earth mat ( ii ) spike earthing made of 20mm gi solid rod ( iii ) g.i earthing strip size 75x8 mm ( iv ) g.i earthing strip size 35x3 mm ( v ) g.i earthing strip size 35x4 mm ( vi ) g.i earthing strip size 40x4 mm ( vii ) g.i earthing strip size 40x5 mm ( viii ) insulated gi / alum.flexible wire 16 sq.mm ( ix ) ace chemrod ( artificial concept of earthing by chemical rod ) : ace chemrod earthing electrode ( consisting mild steel galvanised pipe of size 2500 mm in length x 48 mm outer dia. x 2 mm thick, ms rod of size 2575 mm x 16 mm be welded with bottom. the epoxy insulator of not less than 100 mm length is to be fixed on top of mild steel galvanised pipe. a highly conductive substance is to be filled in residual gap between pipe and rod ) with highly conductive substances not less than 25 kg for soil treatment ( x ) earthing complete conventional type having intermittent layer of charcoal and salt stay set ( i ) gi stay set complete for d / s / s ( 1900x 16mm ) with staywire 7 / 12 swg and guy insulator ( ii ) gi stay set complete for d / s / s ( 1900x 20mm ) with staywire 7 / 10 swg and guy insulator ( iii ) stay set complete ( 1800x20mm ) with stay wire 7 / 10 swg & guy insulator ( galvanised ) ( iv ) 11 kv stay set complete ( 1800x16 mm ) with stay wire 7 / 10 swg and guy insulator ( v ) lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg ( vi ) gi stay wire no. 7 / 8, 7 / 10, 7 / 12, 7 / 14, 7 / 16 p.g.clamps ( i ) p g clamp for 232 / 150 sq mm conductor ( ii ) p g clamp for 80 / 100mm2 ( iii ) p g clamps for 34 / 55mm2 ( iv ) bimettalic clamps for distribution transformers ht side ( 25 to 200 kva ) ( v ) bimettalic clamps for distribution transformers ht side above ( 200 kva ) ( vi ) bimettalic clamps for distribution transformers lt side ( 25 to 200 kva ) ( vii ) bimettalic clamps for distribution transformers lt side above ( 200 kva ) ( viii ) bimettalic clamps for power transformer 5 mva ( ix ) bimettalic clamps for power transformer 10 mva ( x ) bimettalic clamps for vcbs for 33kv and 11 kv ( xi ) bimettalic clamps for ct pt unit ( xii ) p g clamp 3 bolt for abt meters structures, gantry columns and base plates ( i ) structure for 33kv lightening arrestor [ non galvanized ] ( ii ) structure for 33kv lightening arrestor [ galvanized ] ( iii ) structure for 33 kv isolator ( galvanised ) ( iv ) structure for 11 kv isolator ( galvanised ) ( v ) structure for 33 kv isolator [ galvanized ] ( vi ) structure for 11 kv isolator [ galvanized ] ( vii ) structure for 33 kv pt ( non galvanised ) ( viii ) structure for 33 kv pt [ galvanized ] ( ix ) structure for 11 kv pt ( non galvanised ) ( x ) structure for 11 kv pt [ galvanized ] ( xi ) structure for post insulator for 11kv ( galvanised ) ( xii ) structure for post insulator for 33 kv [ galvanized ] ( xiii ) structure for 33 kv hg fuse set ( non galvanised ) ( xiv ) structure for 33 kv hg fuse set [ galvanized ] ( xv ) a swing bus structure ( xvi ) gantry column, girder structures for 33 / 11 kv pss for single transformer [ galvanized ] ( xvii ) a structures for top mounted ab switch on 33 kv bus [ galvanized ] ( xviii ) a structures for top mounted ab switch on 11 kv bus [ galvanized ] ( xix ) a structures for 11 kv take off with top mounted ab switch and provision of lightening arrester [ galvanized ] ( xx ) gi base plate for 33kv ( 500x500x10 mm ) avg weight 19.6kg / plate ( xxi ) stone base plate for 11 kv, dss, lt current and potential transformers ( i ) 33 kv ct outdoor oil immersed type, 3 core, 200 100 / 5 5 1 amp, class 0.5 for differential protection ( ii ) 33 kv ct outdoor oil immersed type, 3 core, 300 150 / 5 5 1 amp, class 0.5 for differential protection ( iii ) 33 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( iv ) 33 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( v ) 33 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vi ) 33 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vii ) 11 kv ct outdoor oil immersed type, 3 core, 600 300 / 5 5 1amp, class 0.5 for differential protection ( viii ) 11 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( ix ) 11 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( x ) 11 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xi ) 11 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xii ) 33 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) ( xiii ) 11 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) power transformer ( i ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( off load tap changer ) ( ii ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( on load tap changer ) ( iii ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( off load tap changer ) ( ivi ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( on load tap changer ) distribution transformer ( i ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 1 ( ii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 2 ( iii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 3 ( iv ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 4 ( v ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 5 ( vi ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 1 ( vii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 2 ( viii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 3 ( ix ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 4 ( x ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 5 ( xi ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 1 ( xii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 2 ( xiii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 3 ( xiv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 4 ( xv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 5 ( xvi ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 1 ( xvii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 2 ( xviii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 3 ( xix ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 4 ( xx ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 5 ( xxi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 1 ( xxii ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 2 ( xxiv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 3 ( xxv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 4 ( xxvi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 5 ( xxvii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxviii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxix ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxx ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxi ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxiii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating ; bis level 2 ( xxxiv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxxv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxvi ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxvii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxviii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxxix ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xl ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xli ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xlii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xliii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xliv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xlv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xlvi ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted ; bis level 5 distribution box ( i ) lt distribution box suitable for 500 kva transformer ( 800 a, isolator & 12 sp mccb of 160 a ) ( ii ) lt distribution box suitable for 400 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 315 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 200 kva transformer ( 400 a, isolator & 9 sp mccb of 160 a ) ( v ) lt distribution box suitable for 100 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( v ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( vii ) ltdb for 100kva & 63kva, isolator 250a, incoming mccb 4p, 200a, 36ka, outgoing mccb 3p 100a, 36ka ( viii ) ltdb for 25kva, isolator 63a, incoming mccb 4p, 63a, 20ka, outgoing mccb 3p 32a, 20ka ( ix ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & 6 tp mccb of 100 a ) ( x ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 6 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xi ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 9 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 3 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 5 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiv ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 8 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xv ) spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement vcb, c&r panel ( i ) 33 kv vcb, 1250 amp., outdoor type, 26.3 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 1200 600 300 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, with metering system in panel with numeric relay announciator ( ii ) 33 kv vcb, 1250 amp., outdoor type, 16 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 600 300 / 1 1a or 400 200 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( iii ) 11 kv vcb, outdoor type, 1250 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 1200 600 300 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va with metering system in panel ( iv ) 11 kv vcb, outdoor type, 800 a, for incoming, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( v ) 11 kv vcb, outdoor type, 630 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va ( vi ) 11 kv vcb, outdoor type, 400 a, for outgoing, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( vii ) indoor type control and relay panel for 33kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. ( viii ) indoor type control and relay panel for 33kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( ix ) indoor type control and relay panel for 11kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( x ) indoor type control and relay panel for 11kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. distribution board ( i ) 415v ac power distribution board ( ii ) 30v dc distribution board pipe connector ( i ) aluminium pipe connector ( ii ) connector pipe to panther ( iii ) connector panther to panther ( iv ) connector panther to ab switch ( v ) connector pipe to pipe ( vi ) connector pipe to dog ( vii ) connector pipe to ab switch ( viii ) connector dog to ab switch copper control cable ( i ) 2.5 mm2 copper 2 core control cable ( armoured ) ( ii ) 2.5 mm2 copper 2 core control cable ( unarmoured ) ( iii ) 2.5 mm2 copper 4 core control cable ( armoured ) ( iv ) 2.5 mm2 copper 4 core control cable ( unarmoured ) ( v ) 2.5 mm2 copper 6 core control cable ( armoured ) ( vi ) 2.5 mm² copper 6 core un armourd cable ( vii ) 7 core x 2.5 sq.mm. armoured control cable ( viii ) 2.5 mm2 copper 8 core control cable ( unarmoured ) ( ix ) 2.5 mm2 copper 10 core control cable ( armoured ) ( x ) 2.5 mm2 copper 10 core control cable ( unarmoured ) ( xi ) 2.5 mm2 copper 12 core control cable ( armoured ) ( xii ) 2.5 mm2 copper 12 core control cable ( unarmoured ) ( xiii ) 19 core x 2.5 sq.mm.armoured control cable capacitor bank ( i ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 3600 kvar ( ii ) 1815 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 kvar+726 kvar+726 kvar 12.1 kv bank shall be complete with capacitor units of 121 kvar at 6.98 kv including allied materials such as suitable size of aluminium busbars, pin / pos ( iii ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 1200 kvar ( iv ) 1089 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 metering equipment ( i ) 33 kv metering cubicle with pt & ct , 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( ii ) 33 kv outdoor type oil immersed ct pt combined metering unit 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( iii ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( modular rack mounted ) of different capacity ( iv ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( projection type ) of different capacity ( v ) 33 kv / 110 v, three phase four wire, ( 0.2s accuracy class for ct and 0.2 accuracy class for pt ) , ratio 1600 / 1a or 1200 / 1a ct pt combined metering unit for feeder ( vi ) metering panel, data concentrator unit ( dcu ) with modem ( vii ) structure for 33 kv metering unit ( viii ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.2s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( ix ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.5s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( x ) trivector energy meter of 800 / 5 amp ( xi ) trivector energy meter of 400 / 5 amp ( xii ) 11 kv, outdoor type oil immersed ct pt combined metering unit, 3 phase 4 wire ( 11kv / 110v ) [ 12 kv pt 50va burden 0.5s accuracy class; ct 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 15 va, 0.5 accuracy class ] ( xiii ) 11 kv metering cubicle with pt ratio 11kv / √3 / 110v and ct ratio 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 0.5 accuracy class for both ( xiv ) ltct electronic meter ( 200 / 150 / 100 / 5 ) 3 phase 4 wire with meter box, class 0.5s accuracy ( xv ) ac 3 phase, 4 wire, 40 200amp lt electronic trivector accuracy class 1.0 dlms compliant category a meter with inbuilt cts and inbuilt 4g with fall back option gprs modem ( xvi ) structure for d.t meter ( xvii ) ac 3 phase dtr meter complete set above 100kva 400 / 5a ( xviii ) lt electronic trivector meter 40 200 amp. ( xix ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 200 / 5a ( xx ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 5a ( xxi ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 5a ( xxii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 1a ( xxiii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 1a ( xxiv ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 1a ( xxv ) 11kv / 110, 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 5a ( xxvi ) 11 kv / 110 v 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 200 / 5 a ( xxvii ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 600 / 1a ( xxviii ) 11 kv / 110, 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 600 / 5 a ( xxix ) dlms compliant, single phase 2 wire 5 30 amp. 1.0 accuracy, class ac statics single phase meter with meter box ( xxx ) lt static energy meter, 3 phase 4 wire, direct connected, 100 amp. with meter box, class 1.0 accuracy ( xxxi ) three phase 4 wire ac static whole current meter, electronic energy meter with box ( 10 60 ) amp ( xxxii ) single phase electronic meter, two wire, 5 30 amp. class 1.0 accuracy with box ( xxxiii ) single phase rf meter with box as per is 13779 standards, dlms compliant ( xxxiv ) three phase rf meter with box as per is 13779 standards, dlms compliant ( xxxv ) single phase rs 232 / 485 prepaid energy meter ( xxxvi ) three phase rs 232 / 485 prepaid energy meter ( xxxvii ) single phase rf prepaid energy meter ( xxxviii ) three phase rf prepaid energy meter ( xxxix ) single phase gprs / gsm prepaid energy meter ( xl ) three phase gprs / gsm prepaid energy meter ( xli ) pvc cable gland sizes 20 mm, ( xlii ) pvc cable gland sizes 25 mm, ( xliii ) pvc cable gland sizes 32 mm ( xliv ) pvc cable gland sizes 40 mm ( xlv ) pvc cable gland sizes 50 mm ( xlvi ) pvc cable gland sizes 63 mm ( xlvii ) pvc cable gland sizes 75 mm ( xlviii ) single phase whole current smart meter ( 5 30 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( xlix ) three phase whole current smart meter ( 10 50 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( l ) three phase whole current smart meter ( 20 100 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( li ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 100 / 5 amp ) ( lii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 200 / 5 amp ) ( liii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio / 5 amp ) ( liv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for feeder ( ct raio / 5amp ) ( lv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. meter box ( ct raio / 5amp ) ( lvi ) field routers / collectors / dcu along with installation clamp and accessories complete ( lvii ) network interface card ( nic ) for smart meter ( lviii ) centralized management console with single 24 led monitor ( lix ) work station consoles with dual 24 led monitor along with operating system, antivirus & license ( lx ) network laserjet ( b / w ) photocopy, scanning and printing ( lxi ) a4 size inkjet / bubble jet printer ( lxii ) a3 size inkjet color printer / all in one color laserjet printer ( lxii ) l.t. ct ratio 50 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 100 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 200 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 300 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 400 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 500 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 600 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 800 / 5a, 5va, 0.5 accuracy for metering, epoxy casted gi service pipe ( i ) gi service pipe 25 mm diameter 3 mtr length ( ii ) gi service pipe 40 mm diameter 3 mtr length ( iii ) gi service pipe 60mm diameter 3 mtr length ( iv ) g.i. pipe 3 dia ring main units ( i ) 11 kv 3 way rmu, 2od + 1vl, one incomer + one breaker + one outgoing ( ii ) 11 kv 4 way rmu, 2od + 2vl, ( one incomer + two breakers + one outgoing ( iii ) 11 kv 5 way rmu, 2od + 3vl, ( one incomer + three breakers + one outgoing ) ( iv ) 11 kv 6 way rmu, 2od + 4vl, ( one incomer + four breakers + one outgoing xlpe insulated cables ( i ) 33 kv ht xlpe cable single core 630mm2 ( armoured ) ( ii ) 1c x 400mm2 cable ( 33 kv power cable ) ( iii ) 33 kv ht xlpe cable 3 core 400 sq mm ( armoured ) ( iv ) 33 kv ht xlpe cable 3 core 300mm2 ( armoured ) ( v ) 33 kv ht xlpe cable 3 core 240mm2 ( armoured ) ( vi ) 33 kv ht xlpe cable 3 core 185mm2 ( armoured ) ( vii ) 33 kv ht xlpe cable 3 core 150mm2 ( armoured ) ( viii ) 33 kv ht xlpe cable 3 core 120mm2 ( armoured ) ( ix ) 33 kv ht xlpe cable 3 core 95mm2 ( armoured ) ( x ) 33 kv ht xlpe cable 3 core 70mm2 ( armoured ) ( xi ) 33 kv ht xlpe cable 3 core 50mm2 ( armoured ) ( xii ) 11 kv 3 core x 35 sq. mm cable ( armoured ) ( xiii ) 11 kv xlpe cable single core 630mm2 ( armoured ) ( xiv ) 3core x 630sq mm ( 11 kv power cable ) ( xv ) 11 kv xlpe cable 3 core 400mm2 ( armoured ) ( xvi ) 11 kv xlpe cable 3 core 300mm2 ( armoured ) ( xvii ) 11 kv xlpe cable 3 core 240 mm2 ( armoured ) ( xviii ) 11 kv xlpe cable 3 core 185mm2 ( armoured ) ( xix ) 11 kv xlpe cable 3 core 150mm2 ( armoured ) ( xx ) 11 kv xlpe cable 3 core 120mm2 ( armoured ) ( xxi ) 11 kv xlpe cable 3 core 95mm2 ( armoured ) ( xxii ) 11 kv xlpe cable 3 core 70mm2 ( armoured ) ( xxiii ) 11 kv xlpe cable 3 core 50mm2 ( armoured ) ( xxiv ) 11 kv xlpe cable 3 core 25mm2 ( armoured ) ( xxv ) power cable for dt meter 120 sq.mm unarmoured ( xxvi ) power cable for dt meter 240 sq.mm unarmoured ( xxvii ) lt xlpe cable 4 core 16 mm2 ( armoured ) ( xxviii ) lt xlpe cable 4 core 16mm2 ( unarmoured ) ( xxix ) lt xlpe cable 4 core 25mm2 ( armoured ) ( xxx ) lt xlpe cable 3.5 core 300mm2 ( armoured ) ( xxxi ) lt xlpe cable 3.5 core 185mm2 ( armoured ) ( xxxii ) lt xlpe cable 3.5 core 120mm2 ( armoured ) ( xxxiii ) lt xlpe cable 3.5 core 95 mm2 ( armoured ) ( xxxiv ) lt xlpe cable 3.5 core 50mm2 ( armoured ) ( xxxv ) lt xlpe cable 3.5 core 25mm2 ( armoured ) ( xxxvi ) lt xlpe cable 2 core 16 mm2 ( armoured ) ( xxxvii ) lt xlpe cable 2 core 10mm2 ( armoured ) ( xxxviii ) lt xlpe cable 2 core 6mm2 ( armoured ) ( xxxix ) lt xlpe cable 1cx120 sqmm ( armoured ) ( xl ) lt xlpe single core cable 95 mm2 ( armoured ) ( xli ) lt xlpe single core cable 50 mm2 ( armoured ) ( xlii ) lt xlpe single core cable 25 mm2 ( armoured ) ( xliii ) lt xlpe cable 3.5 core 35 sq. mm. ( armoured ) ( xliv ) lt xlpe cable 3.5 core 70 sq. mm. ( armoured ) ( xlv ) lt xlpe single core unarmoured 1 x 400 sqmm pvc insulated cables ( i ) 3.5 core 300 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ii ) 3.5 core 240 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iii ) 3.5 core 185 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iv ) 3.5 core 150 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( v ) 3.5 core 70 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vi ) 3.5 core 35 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vii ) 2 core 16 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( viii ) 1 core 120 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ix ) lt pvc cable 3.5 core 95 mm2 ( armoured ) ( x ) lt pvc cable 3.5 core 10 mm2 ( armoured ) ( xi ) lt pvc cable 3.5 core 6 mm2 ( armoured ) ( xii ) lt pvc cable 2 core 16 mm2 ( armoured ) ( xiii ) lt pvc cable 2 core 10 mm2 ( armoured ) ( xiv ) lt pvc cable 2 core 6 mm2 ( armoured ) ( xv ) lt pvc cable 2 core 4 mm2 ( armoured ) ( xvi ) lt pvc cable 1 core 16 mm2 ( armoured ) ( xvii ) lt pvc cable 1 core 50 mm2 ( armoured ) ( xviii ) lt pvc cable 1 core 70 mm2 ( armoured ) ( xix ) lt pvc cable 1 core 150 mm2 ( armoured ) ( xx ) lt pvc cable 1 core 300 mm2 ( armoured ) ( xxi ) pvc single phase service cable 3.5 core 25 mm2 ( amoured ) ( xxii ) 2.5 sq mm twin core pvc service cable ( armoured ) ( xxiii ) 4 sq mm twin core pvc service cable ( unarmoured ) ( xxiv ) pvc single phase service cable 2 core 2.5 mm2 ( unamoured ) ( xxv ) pvc single phase service cable 2 core 6 mm2 ( unarmoured ) ( xxvi ) pvc three phase service cable 4 core 6 mm2 ( armoured ) ( xxvii ) pvc three phase service cable 4 core 8 mm2 ( armoured ) ( xxviii ) pvc three phase service cable 4 core 10 mm2 ( armoured ) ( xxix ) pvc three phase service cable 4 core 16 mm2 ( armoured ) ( xxx ) pvc three phase service cable 4 core 25 mm2 ( armoured ) ( xxxi ) pvc three phase service cable 4 core 10 mm2 ( unarmoured ) aerial bunched cables ( i ) 11 kv xlpe ht ab cable 3cx185mm2+240mm2 bare messenger ( ii ) 11 kv xlpe ht ab cable 3cx185mm2+150mm2 bare messenger ( iii ) 11 kv xlpe ht ab cable 3cx150mm2+120mm2 bare messenger ( iv ) 11kv xlpe ht ab cable 3cx120 mm2 + 95mm2 bare messenger ( v ) 11 kv xlpe ht ab cable 3cx95mm2+80mm2 bare messenger ( vi ) 11 kv xlpe ht ab cable 3cx70mm2+70mm2 bare messenger ( vii ) 11 kv xlpe ht ab cable 3cx50mm2+70mm2 bare messenger ( viii ) 11 kv xlpe ht ab cable 3cx35mm2+70mm2 bare messenger ( ix ) 11 kv xlpe ht ab cable 3cx35mm2+35mm2 bare messenger ( x ) lt xlpe ab cable 3cx120+1cx70+1cx16 mm2 ( xi ) lt xlpe ab cable 3cx95 sqmm + 1x70 sqmm+1x70 sq mm ( xii ) lt xlpe ab cable 3cx95+1cx70+1cx16 mm2 ( xiii ) lt xlpe ab cable 3x70+1x50+1x16 ( street light ) mm2 ( xiv ) lt xlpe ab cable 3cx50 sqmm + 1x35 sqmm+1x16 sq mm ( xv ) lt xlpe ab cable 3x50+1x25+1x35 mm2 ( xvi ) lt xlpe ab cables 1x16 ( ph ) + 1x25 ( bare condustor + 1x16 ( insulated street lighting ) mm2 ( xvii ) lt xlpe ab cable 3cx120+70mm2 ( xviii ) lt xlpe ab cable 3cx95+70mm2 ( xix ) lt xlpe ab cable 3cx50+35mm2 ( xx ) lt xlpe ab cable 3cx35+25mm2 ( xxi ) lt xlpe ab cable 3cx25+25mm2 ( xxii ) lt xlpe ab cable 3cx16+25mm2 ( xxiii ) lt xlpe ab cable 1cx16+25mm2 single phase ab cable accessories ( i ) 11 kv ab cable straight thru joint kit suitable for 35 70 sqmm ( ii ) 11 kv ab cable straight thru joint kit suitable for 95 120 sqmm ( iii ) 11 kv abc termination kit 35 70 sqmm ( iv ) 11 kv abc termination kit 95 120 sqmm ( v ) lt pre insulated mid span joint suitable 25 mm2 phases ( vi ) lt pre insulated mid span joint suitable 35 mm2 phases ( vii ) lt pre insulated mid span joint suitable 50 mm2 phases ( viii ) lt pre insulated mid span joint suitable 70 mm2 phases ( ix ) lt pre insulated mid span joint suitable 95 mm2 phases ( x ) lt pre insulated mid span joint suitable 120 mm2 phases ( xi ) pre insulated mid span joint suitable for 25 mm2 neutral messenger ( xii ) pre insulated mid span joint suitable for 35 mm2 neutral messenger ( xiii ) pre insulated mid span joint suitable for 50 mm2 neutral messenger ( xiv ) insulation piercing connector for db charging ( xv ) insulation piercing connector branching suitable for t joints ( xvi ) piercing connector for lt ab cable ( xvii ) insulation piercing connector type i ( main 16 95 mm2 & tap 4 50 mm2 ) ( xviii ) insulation piercing connector type ii ( main 16 120 mm2 & tap 16 120 sq mm ) ( xix ) satellite connector ( xx ) lt ab cable accessory, 1.1mtr. stainless steel strap if207 ( 20x0.7 ) ( xxi ) buckle for strap ( xxii ) suspension clamp with eyehook ( xxiii ) suspension clamp suitable for 25 70 sqmm baremessenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxiv ) suspension clamp suitable for 35 95 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxv ) suspension clamp suitable for 95 150 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxvi ) dead end clamp with eyehook ( xxvii ) dead end clamp suitable for 25 70 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxviii ) dead end clamp suitable for 70 95 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxix ) dead end clamp suitable for 95 150 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxx ) dead end clamp assembly suitable upto 25 sq.mm bare messenger ( 01 dead end clamp with bracket, 2 mtr. stainless steel straps, 02 nos. buckles ) ( xxxi ) suspension clamp assembly suitable for 95 mm2 bare messenger ( 01 nos. suspension clamp with bracket, 2 mtr. stainless stell straps 02 nos. buckles ( xxxii ) service main anchor clamp for proper support of service cable ( 4mm2 and 10 mm2 ) ( xxxiii ) eye hook ( xxxiv ) stainless steel strip of 20mmx1mmx1000mm with buckle clip fabricated items ( i ) hot dip galvanized fabricated iron material for 33 kv line, lt line & dss ( ii ) 33 kv pole top bracket 50x10 mm flat [ galvanized ] ( 2.5 kgs. ) ( iii ) 33 kv pole top bracket 65x65x6 mm [ galvanized ] ( 3.58 kgs. ) ( iv ) 33 kv pole top bracket [ non galvanized ] ( 2.9 kgs. ) ( v ) 11kv pole top bracket 50x8 mm [ galvanized ] ( 2.2 kgs. ) ( vi ) 11 kv pole top bracket 50x8 mm ( f type ) [ non galvanized ] ( 2.2 kgs, ) ( vii ) 11 kv f clamp / bracket ( 2.1 kgs. ) ( viii ) 11 kv fish plate ( 1.6 kgs. ) ( ix ) 33 kv fish plate ( for st pole 13 mtr. ) ( 3 kgs, ) ( x ) 33kv v cross arm for ( 100x50x6 mm ) [ galvanized ] ( 19.7 kgs. ) ( xi ) 33 kv v cross arm ( 100x 50x 6 mm ) [ non galvanized ] ( 19.7 kgs. ) ( xii ) 33 kv dp special type v cross arm [ galvanised ] ( 21 kgs. ) ( xiii ) 11kv v cross arm ( 100x50x6 mm ) , [ galvanized ] ( 16 kgs. ) ( xiv ) 11kv v cross arm ( 75x40x6 mm ) , [ galvanized ] ( 14.6 kgs. ) ( xv ) 11 kv v cross arm ( 75 x 40 x6 mm ) [ non galvanized ] ( 14.6 kgs. ) ( xvi ) ms angle ( 65x65x6 mm ) for guarding of 33 kv [ galvanized ] ( 16 kgs. ) ( xvii ) ms angle ( 65x65x6 mm ) for guarding of 11 kv [ galvanized ] ( 13.6 kgs. ) ( xviii ) ms angle ( 65x65x6 mm ) for guarding of 33 kv, 11 kv, l.t line [ non galvanized ] ( 13.6 kgs. ) ( xix ) top channel set ( 100x50x6 mm ) 3200 mm length [ galvanized ] ( 66.2 kgs. ) ( xx ) top channel set ( 100x50x6 mm ) [ non galvanized ] ( 66.2 kgs. ) ( xxi ) ms channel for ab switch ( 100x50x6 mm ) [ galvanized ] ( 28.16 kgs. ) ( xxii ) ms channel ab switch ( 100x50x6 mm ) [ non galvanized ] ( 28.16 kgs. ) ( xxiii ) 33kv d p channel ( 100x50x6 mm ) 3150 mm long [ galvanized ] ( 65.2 kgs. ) ( xxiv ) 33kv d p channel ( 100x50x6 mm ) 2200 mm long [ galvanized ] ( 45.5 kgs. ) ( xxv ) 33kv d p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] ( 26.9 kgs. ) ( xxvi ) 33 kv d.p channel ( 100x50x6 mm ) 1.3 meter [ non galvanized ] ( 26.9 kgs. ) ( xxvii ) 11kv d p channel ( 75x40x6 mm ) [ galvanized ] ( 41.3 kgs. ) ( xxviii ) 11kv d.p channel ( 75x40x6mm ) [ non galvanized ] ( 41.3 kgs. ) ( xxix ) transformer base channel ( 100x50x6 mm ) [ galvanized ] ( 52.63 kgs. ) ( xxx ) transformer base channel ( 100x50x6 mm ) [ non galvanized ] ( 52.63 kgs. ) ( xxxi ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ galvanized ] ( 52.3 kgs. ) ( xxxii ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ non galvanized ] ( 52.3 kgs. ) ( xxxiii ) belting angle a ( 65x65x6 mm ) [ galvanized ] ( 31 kgs. ) ( xxxiv ) belting angle b ( 65x65x6 mm ) [ galvanized ] ( 28 kgs. ) ( xxxv ) back clamp ( 50x6 mm ) for v xrm & & top bracket for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvi ) back clamp ( 50x8 mm ) for guarding angle for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvii ) back clamp ( 50x8 mm ) for guarding angle for 9 mtr. psc pole [ galvanized ] ( 3 kgs. ) ( xxxviii ) back clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 3.2 kgs. ) ( xxxix ) back clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 3.2 kgs. ) ( xl ) back clamp ( 50x8 mm ) for v xrm & top bracket for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xli ) back clamp ( 50x6 mm ) for v arm & top bracket 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xlii ) back clamp ( 50x6 mm ) for 9mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( xliii ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( xliv ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( xlv ) back clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 2 kgs. ) ( xlvi ) back clamp ( 50x6 mm ) for tublar pole [ non galvanized ] ( 2 kgs. ) ( xlvii ) support clamp for v cross arm for 60kg rail pole [ galvanized ] ( 1.6 kgs. each ) ( xlviii ) support clamp for v cross arm for 60kg rail pole [ non galvanized ] ( 1.6 kgs. each ) ( xlix ) support clamp for v cross arm for 9 mtr 400kg psc pole [ galvanized ] ( 1.2 kgs. each ) ( l ) support clamp for v cross arm for 9 mtr 400kg psc pole [ non galvanized ] ( 1.2 kgs. each ) ( li ) support clamp for v cross arm for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. each ) ( lii ) support clamp for v cross arm for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. each ) ( liii ) support clamp for v cross arm for tublar pole [ galvanized ] ( 1.4 kgs. each ) ( liv ) support clamp for v cross arm for tublar pole [ non galvanized ] ( 1.4 kgs. each ) ( lv ) back clamp a for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvi ) back clamp b for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvii ) back clamp for 33 kv dp special type v cross arm [ galvanised ] ( 3 kgs. each ) ( lviii ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ galvanized ] ( 3.7 kgs. ) ( lix ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ non galvanized ] ( 3.7 kgs. ) ( lx ) clamp for top channel 50x6 mm flat for 60kg rail pole [ galvanized ] ( 2.8 kgs. ) ( lxi ) clamp for top channel 50x6 mm flat for 60kg rail pole [ non galvanized ] ( 2.8 kgs. ) ( lxii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( lxiii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( lxiv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( lxv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( lxvi ) clamp for top channel 50x6 mm flat for tublar pole [ galvanized ] ( 2 kgs. ) ( lxvii ) clamp for top channel 50x6 mm flat for tublar pole [ non galvanized ] ( 2 kgs. ) ( lxviii ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 2.4 kgs. ) ( lxix ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 2.4 kgs. ) ( lxx ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( lxxi ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( lxxii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( lxxiii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( lxxiv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ galvanized ] ( lxxv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ non galvanized ] ( lxxvi ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ galvanized ] ( 19.3 kgs. ) ( lxxvii ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ non galvanized ] ( 19.3 kgs. ) ( lxxviii ) clamp ( 50 x 6 mm ) for transformer base channel [ galvanized ] ( 3.2 kgs. ) ( lxxix ) clamp ( 50 x 6 mm ) for transformer base channel [ non galvanized ] ( 3.2 kgs. ) ( lxxx ) clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] ( 1.872 kgs. ) ( lxxxi ) clamp ( 50 x 6 mm ) for transformer belting [ non galvanized ] ( 1.872 kgs. ) ( lxxxii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] ( 1.872 kgs. ) ( lxxxiii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ non galvanized ] ( 1.872 kgs. ) ( lxxxiv ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 60kg rail pole [ galvanized ] ( 2.25 kgs. each ) ( lxxxv ) d.p channel support clamp ( 50x6 mm ) ) for 60kg rail pole [ non galvanized ] ( 2.25 kgs. each ) ( lxxxvi ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.5 kgs. each ) ( lxxxvii ) d.p channel support clamp ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.5 kgs. each ) ( lxxxviii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.1 kgs. each ) ( lxxxix ) d.p channel support clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ nongalvanized ] ( 1.1 kgs. each ) ( xc ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ galvanized ] ( 4.5 kgs. each ) ( xci ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ non galvanized ] ( 4.5 kgs. each ) ( xcii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ galvanized ] ( 1.92 kgs. ) ( xciii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( xciv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( xcv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( xcvi ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( xcvii ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( xcviii ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ galvanized ] ( 1.8 kgs. ) ( xcix ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ non galvanized ] ( 1.8 kgs. ) ( c ) 33kv cross bracing for d p structure ( 50x50x6 ) [ galvanized ] ( 64.3 kgs. ) ( ci ) 33 kv cross bracing for dp channel [ non galvanized ] ( 64.3 kgs. ) ( cii ) 11 kv cross bracing for d p structure [ galvanized ] ( 51.7 kgs. ) ( ciii ) 11 kv cross bracing for d p structure [ non galvanized ] ( 51.7 kgs. ) ( civ ) clamp for cross bracing set of 2 pair for 60kg rail pole [ galvanized ] ( 1.872 kgs. each ) ( cv ) clamp for cross bracing set of 2 pair for 60kg rail pole [ non galvanized ] ( 1.872 kgs. each ) ( cvi ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ galvanized ] ( 1.3 kgs. ) ( cvii ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ non galvanized ] ( 1.3 kgs. ) ( cviii ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole [ galvanized ] ( 1.2 kgs. ) ( cix ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole non [ galvanized ] ( 1.2 kgs. ) ( cx ) clamp for cross bracing set of 2 pair for tublar pole [ galvanized ] ( 1.75 kgs. ) ( cxi ) clamp for cross bracing set of 2 pair for tublar pole [ non galvanized ] ( 1.75 kgs. ) ( cxii ) support clamp for cross bracing for 60kg rail pole [ galvanized ] ( 2.5 kgs. each ) ( cxiii ) support clamp for cross bracing for 60kg rail pole [ non galvanized ] ( 2.5 kgs. each ) ( cxiv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ galvanized ] ( 2.33 kgs. each ) ( cxv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ non galvanized ] ( 2.33 kgs. each ) ( cxvi ) support clamp for cross bracing for 8 mtr 200kg psc pole [ galvanized ] ( 1.68 kgs. each ) ( cxvii ) support clamp for cross bracing for 8 mtr 200kg psc pole [ non galvanized ] ( 1.68 kgs. each ) ( cxviii ) support clamp for cross bracing for tublar pole [ galvanized ] ( 2.1 kgs. each ) ( cxix ) support clamp for cross bracing for tublar pole [ non galvanized ] ( 2.1 kgs. each ) ( cxx ) angle / side stay clamp ( 50x8 mm ) for 13 mtr. stp pole [ galvanized ] ( 2.1 kgs. ) ( cxxi ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 1.92 kgs. ) ( cxxii ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( cxxiii ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( cxxiv ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( cxxv ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( cxxvi ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( cxxvii ) angle / side stay clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 1.92 kgs. ) ( cxxviii ) angle / side stay clamp ( 50 x 6 mm ) for tublar pole [ non galvanized ] ( 1.92 kgs. ) ( cxxix ) clamp for g.i. pipe ( 2.02 kgs. ) ( cxxx ) gi flat ( 75x6 mm ) [ galvanized ] ( 1.1 kgs. ) ( cxxxi ) ms flat ( 75x6 mm ) [ non galvanized ] ( 1.1 kgs. ) ( cxxxii ) earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] ( 1.8 kgs. ) ( cxxxiii ) earth clamp for earthwire ( 50 x 6 mm ) [ non galvanized ] ( 1.8 kgs. ) ( cxxxiv ) ms angle for lt distribution bus ( 50x50x6 mm ) [ galvanized ] ( cxxxv ) ms angle for l t distribution bus ( 50x50x6 mm ) [ non galvanized ] ( cxxxvi ) lt bracket vertical formation ( cxxxvii ) lt bracket for tapping point ( cxxxviii ) lt angle bracket ( 50x50x6 mm ) [ galvanized ] ( cxxxix ) lt angle bracket ( 50x50x6 mm ) [ non galvanized ] ( cxl ) pole clamp for i hook b type ( 0.8 kgs. each ) ( cxli ) lt back clamp ( 50 x 6 mm ) for lt angle [ galvanized ] ( 0.55 kgs. each ) ( cxlii ) lt back clamp ( 50 x 6 mm ) for lt angle [ non galvanized ] ( 0.55 kgs. each ) ( cvliii ) u clamp ( 40 x 6 mm ) [ galvanized ] ( 1.46 kgs. ) ( clxiv ) u clamp ( 40 x 6 mm ) [ non galvanized ] ( 1.46 kgs. ) ( clxv ) 50 x 6 mm galvanized gi flat ( risers ) ( clxvi ) 25 x 3 mm galvanized gi flat ( risers ) fuse ( i ) 11 kv d.o. fuse unit ( polymer type ) ( ii ) 33 kv d.o. fuse unit ( polymer type ) ( iii ) 33 kv h.g. fuse unit ( polymer type ) ( iv ) 11 kv h.g. fuse unit ( polymer type ) electrical conduit ( pipes ) ( i ) gi pipe 4 medium duty ( b class ) ( ii ) gi pipe 6 medium duty ( b class ) ( iii ) gi pipe 8 medium duty ( b class ) ( iv ) hume pipe rcc pipe 100 mm ( np2 class ) ( v ) hume pipe rcc pipe 150 mm ( np2 class ) ( vi ) hume pipe rcc pipe 200 mm ( np3 class ) ( v ) hdpe pipe 110 mm / 4 pe 63 grade ( vi ) hdpe pipe 160 mm / 6 pe 63 grade ( vii ) hdpe pipe 200 mm / 8 pe 63 grade heat shrinkable kit ( i ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 ( ii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 300 mm2 ( iii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 240mm2 ( iv ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 185 mm2 ( v ) 33 kv 3 core heat shrikable straight through cable jointing kit for 150 95 mm2 ( vi ) 33 kv 3 core heat shrikable straight through cable jointing kit for 70 35 mm2 ( vii ) 33 kv termination kit for 1core x 400mm2 ( viii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 400mm2 ( ix ) 33 kv 3 core heat shrinkable out door type cable termination kit for 300 mm2 ( x ) 33 kv 3 core heat shrinkable out door type cable termination kit for 240 mm2 ( xi ) 33 kv 3 core heat shrinkable out door type cable termination kit for 185 mm2 ( xii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 120 mm2 ( xiii ) 33 kv 3 core heat shrikable out door cable termination kit for 95 70 mm2 ( xiv ) 33 kv 3 core heat shrikable indoor cable termination kit for 400mm2 ( xv ) 33 kv 3 core heat shrikable indoor cable termination kit for 300 mm2 ( xvi ) 33 kv 3 core heat shrikable indoor cable termination kit for 240 mm2 ( xvii ) 33 kv 3 core heat shrikable indoor cable termination kit for 185 mm2 ( xviii ) 33 kv 3 core heat shrikable indoor cable termination kit for 120 mm2 ( xix ) 33 kv 3 core heat shrikable indoor cable termination kit for 95 70 mm2 ( xx ) 33 kv 3 core heat shrikable indoor cable termination kit for 50 25 mm2 ( xxi ) in door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxii ) out door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxiii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 400 mm2 ( xxiv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 300 mm2 ( xxv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 240 mm2 ( xxvi ) 11 kv 3 core heat shrinkable straight through cable jointing kit 185 mm2 ( xxvii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 95 150 mm2 ( xxviii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 70 35 mm2 ( xxix ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 400 mm2 ( xxx ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 300 mm2 ( xxxi ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 240 mm2 ( xxxii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 120 185 mm2 ( xxxiii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 95 50 mm2 ( xxxiv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 400 mm2 ( xxxv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 300 mm2 ( xxxvi ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 240 mm2 ( xxxvii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 120 185 mm2 ( xxxviii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 95 50 mm2 ug cables related material ( i ) pillar box cum consumer service distribution box one time lock system ( 1 no. 3 ph 4 wire incoming and 5 nos. 3ph 4 wire outgoing ) ( ii ) cable marker ( metal ) ab switch contact ( i ) male female contact of 33 kv ab switch 600 630 amp ( ii ) male female contact of 33 kv ab switch 400 amp ( iii ) male female contact of 33 kv ab switch 200 amp ( iv ) male female contact of 11 kv ab switch 800 amp ( v ) male female contact of 11 kv ab switch 600 amp ( vi ) male female contact of 11 kv ab switch 400 amp ( vii ) male female contact of 11 kv ab switch 200 amp testing equipment ( i ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt whole current single phase meters up to 60a ( ii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt 3 phase & ct operated energy meters ( iii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh for ht+ : to test meters suitable for ht, 3 phase, 3 wire and 4 wire systems ( iv ) eh ii chain electric hoist ( capacity 1 ton, standard lift 3 mtr ) with 1.5 hp motor ( v ) electronic weighing machine with 1.2x1.2 mtr. platform, suitable for weighing limit upto 2 tons ( vi ) electronic weighing machine with 2x2 mtr. platform, suitable for weighing limit upto 4 tons ( vii ) earth tester 200 amp. 2000 ohm ( digital ) ( viii ) 500 v megger ( ix ) 2.5 / 5 kv megger ( mannual ) ( x ) digital clamp meter ( meco 3150 ) ( xi ) digital tong tester ( 1000 amp., 500 v ) with associated accessories. ( xii ) digital multi meter ( 10 amp along with ma range ) ( xiii ) 2.5 kv motorised with range up to 20000 mega ohms ( xiv ) 2.5 kv motorised cum manual with range up to 20000 mega ohms ( xv ) 5 kv motorised with range up to 100000 mega ohms ( xvi ) 5 kv motorised cum manual with range up to 100000 mega ohms tool kit ( i ) adhesive insulation tape ( ii ) high temperature tape ( iii ) dicharge rod for 33 kv / 11kv ( iv ) screw driver set 840 ( v ) screw driver set 935 ( vi ) neon tester 813 ( vii ) hammer 200 gm ( viii ) hack saw frame ( ix ) hack saw blades ( x ) adjustable spanner ( xi ) wire stripper ( xii ) combinational plier ( xiii ) side cutting plier ( xiv ) measuring tape ( xv ) hand drill machine ( xvi ) punch ( xvii ) knife ( xviii ) spanner set ( xix ) tool bag ( xx ) nose plier ( xxi ) drill bit 3 / 10 concrete ( jk ) ( xxii ) chain pulley 5ton with 15 meter chain ( xxiii ) max pulley 10 ton civil works ( i ) opc cement scada related materials ( a ) scada server ( i ) fep server with interface switches for rtus and frtus ( ii ) isr server { data server } ( iii ) nms server { dms server } ( iv ) dts server ( only at ranchi ) ( v ) developmental server ( vi ) communication server ( vii ) web / directory server ( viii ) workstation with dual tft monitors ( ix ) led based video projection system with 2x3 module configuration with each module at least 67 diagonal with common projector ( x ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 1f ) ( xi ) 33 kv or 11 kv control and relay panel, scada compatable for transformer protection ( it ) with o / c +e / f + diff relay ( xii ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 2f ) ( xiii ) buchholz relay contact ( xiv ) minimum oil gauge ( xv ) scada compatible winding temp. indicator ( xvi ) scada compatible oil temp. indicator ( xvii ) rtu base equipment comprising panels, racks, sub racks, powe suppy modules, cpu, analog and digital input control output modules, interfacing mft using rs 485 modbus protocol and 2 ethernet ports + 4 serial ports ( rs232 / 485 ) , required a d converters and all other accessories required ( xviii ) dc voltage transducer ( xix ) rtu base and foundation ( base should be capable of withstanding 200 kg. load ) ( xx ) multi function transducers ( 5 amps, 110 v with rs 485 modbus communication protocol ) ( xxi ) type a frtu for 5 way rmus ( xxii ) type a frtu for 4 way rmus ( xxiii ) type b frtu for 3 way rmus ( xxiv ) type c frtu for 2 way rmus ( xxv ) routers 230 v ac, 2 ge ports, 48xfe, wan speed 200 mbps ( xxvi ) ethernet switch ( xxvii ) 2 mbps vpn link for connectivity for s / s with scada control center ( xxviii ) ldms ( xxix ) 2 kva ups ( for ldms ) with 160 ah battery, 72 v battery set ( xxx ) gsm / gprs modem along with accessories ( xxxi ) b / w laser printer for ldms ( xxxii ) 48 v dc power supply system based on smps for rtu & comm. equipment with 80 ah battery ( xxxiii ) cat 6 cable ( xxxiv ) ldms software ( xxxv ) numerical relay scada compatible for power transformer protection ( xxxvi ) numerical relay scada compatible for 33kv and 11 kv feeder protection ( xxxvii ) mcu module card ( xxxviii ) power module card ( xxxix ) di card ( xl ) do card ( xli ) ai card ( xlii ) com 6 card ( xliii ) rmu 3 way ( 1 incomer, 1 outgoing and 1 breaker ) scada compatible ( xliv ) rmu 5 way ( 1 incomer, 1 outgoing and 3 breakers ) scada compatible ( xlv ) 11 kv sectionalizer ( xlvi ) 11 kv auto reclosure ( xlvii ) gprs / cdma / edge / 3g modem ( xlviii ) heavy duty relay for cb trip / close ( 48 v dc, 2 no, 1 nc ) ( xlix ) 48 v dcps at rtu locations along with vrla batteries ( l ) 11 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( li ) 33 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( b ) storage & backup devices ( i ) external raid mass storage device ( for 2 months online backup ) ( ii ) external dat drive ( c ) switches ( i ) layer ii switch ( scada / dms lan ) ( 48 ports ) ( ii ) layer switch ( planning & development system lan ) ( 24 ports ) ( d ) other active devices ( i ) gps time synchronization system ( ii ) time, day & date digital displays ( e ) printers ( i ) a3 color inkjet printer ( ii ) b / w laser printer ( iii ) color laser printer ( f ) security system ( dmz ) ( i ) web server with load balancing ( ii ) firewall & network ids / ips in pair ( 2 nos. ) ( g ) cabling system ( i ) cable, jacks, hubs, etc. ( ii ) acdb for control centre ( iii ) kvm switch ( iv ) panels ( h ) software for control centre ( i ) scada software ( ii ) isr software ( iii ) dms software ( iv ) dts software ( v ) developmental software ( vi ) network management software ( viii ) gis adaptor / engine for importing data from gis system under it system ( i ) form: f 4: rtu:rtu type b 33 / 11 kv sub stations ( i ) rtu base equipment comprising panels, racks, sub racks, power supply modules, cpu, analog and digital input control output modules, interfacing equipments for interfacing mfts using rs 485 modbus protocol and 2 eathernet ports, required a d converters & all other required items / accessories including complete wiring for all modules for locations mentioned for type b rtus ( ii ) multifunction transducers ( mfts ) ( iii ) contact multiplying relays ( cmrs ) ( iv ) heavy duty relays ( hdrs ) for cb trip / close and rise and lower of oltc ( v ) weather transducer wind speed ( vi ) weather transducer rainfall ( vii ) weather transducer humidity ( viii ) weather transducer temperature ( ix ) weather transducer wind direction ( x ) router for rtus at dc power supply ( xi ) oltc transducers ( xii ) dc current transducer ( xiii ) dc voltage transducer ( xiv ) acdb with sufficient mccbs ( j ) test equipments for rtu ( i ) rtu database configuration & maintenance software tool ( ii ) master station cum rtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( k ) form: f 5:frtu / frtus ( i ) type a frtu for 5 way rmus ( ii ) type a1 frtu for 4 way rmus ( iii ) type b frtu for 3 way rmus ( iv ) type c frtu for sectionalizers ( v ) mfts ( vi ) contact multiplying relays ( cmrs ) ( vii ) heavy duty relays for cb trip / close ( l ) test equipments for frtu ( i ) frtu database configuration & maintenance software tool ( ii ) master station cum frtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( m ) f4: gprs / cdma / edge / 3gmodems ( i ) gprs ( n ) form: f 7: auxiliary power supply system ( aps ) ( i ) 20 kva ups ( 1+1 ) with vrla batteries to give 4 hrs back up ( ii ) dc power supply ( dcps ) system based on smps ( for 20 a load plus charging current@10% capacity ) with vrla batteries to give 4 hrs back up. ( iii ) 2 kva ups for rtu locations / ldms ( iv ) 48 v dcps at rtu locations along with vrla batteries ( v ) 24 / 48 v dcps for frtu locations along with vrla batteries safety equipment ( i ) rechargeable led hand torch ( ii ) safety helmet pvc ( iii ) safety shoes ( electrical safety ) ( iv ) rubber hand gloves ( 1.1kv ) commander ( v ) safety double adjustable belts ( karam ) ( vi ) safety items as per the requirement of electrical inspector as under first aid box, shock treatment chart, rubber matts 8 mm thick, 4 fire buckets with sand & m.s. hooks / stand, helmet, hand gloves and, fire extinguisher ( 2 nos ) fire extinguishers ( i ) i kg dry chemical powder ( map 50% ) ; fire rating : 1a, 8b ( ii ) 2 kg dry chemical powder ( map 50% ) ; fire rating: 2a, 8b ( iii ) 4 kg dry chemical powder ( map 50% ) ; fire rating : 2a, 21b ( iv ) 6 kg dry chemical powder ( map 50% ) ; fire rating: 3a, 34b ( v ) 9 kg dry chemical powder ( map 50% ) fire rating: 4a, 55b ( vi ) 6 ltr water type; fire rating : 2a ( vii ) 9 ltr water type, fire rating: 3a ( viii ) 6 ltr mechanical foam type, fire rating: 2a, 21b ( ix ) 9 ltr mechanical foam type, fire rating: 4a, 34b ( x ) 2 kg carbon dioxide type, fire rating: 8b ( xi ) 3 kg carbon dioxide type, fire rating: 13b ( xii ) 4.5 kg carbon dioxide type, fire rating: 21b ( xiii ) 6.5 kg carbon dioxide type, fire rating: 55b ( xiv ) 9 kg carbon dioxide type, fire rating: 70b ( xv ) 22.5 kg carbon dioxide type, fire rating: 70b ( xvi ) gas pressure ctc fire extinguisher ( xvii ) fire buckets ( capacity 10 ltrs. ) feeder pillar / smdb / distribution board ( i ) lt mini feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) ( ii ) smdb ( 1 in, 3 out ) with housing 5 nos 20 amp spn mcb, ( iii ) tpn distribution board 12 way, 50 amp tpn mcb, ( iv ) tpn distribution board 12 way, 100 amp tpn mcb, ( v ) tpn distribution board 12 way, 150 amp tpn mcb, ( vi ) lt feeder piller box for 1 phase 8 connection made of m.s.sheet. ( vii ) lt feeder piller box for 1 phase 12 connection made of m.s.sheet. ( viii ) lt feeder piller box for 3 phase 4 connection made of m.s.sheet. ( ix ) lt feeder piller box for 3 phase 8 connection made of m.s.sheet. ( x ) lt feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) aluminium end terminal lugs 10 sq mm 16 sq mm 25 sq mm 32 sq mm 50 sq mm 70 sq mm 95 sq mm 120 sqmm 150 sq mm 185 sq mm 225 sq mm 240 sq mm 300 sqmm 400 sq mm other misc. equipment ( i ) earthing g.i.strip ( 65x6 ) mm2 ( ii ) rain coat ( iii ) rubber mat along length of pannel ( iv ) aluminium pipe 40 mm dia ( v ) 400 watt / 250 v hpsv lamp fitting complete for 33 / 11 kv pss yard lightining ( vi ) 30 v 80 ah battery charging unit complete with battery and stand ( vii ) 30 volts 100 ah lead acid battery with battery charger and stand ( viii ) 30v, 40 amp. float cum boost battery charger with full wave rectification for 230 v, 1 phase, 50 hz ac input supply as per technical specifications. ( ix ) polycarbonate seal bit ( x ) sticker seal with hologram ( xi ) earth knob ( xii ) ms earth mat for switch yard ( xiii ) rail piece 44.64kg / m 6.92 meter long for power transformer ( xiv ) aluminium binding wire ( xv ) gi wire no. 6 / 8 / 10 ( xvi ) t / c fuse wire 12 / 14 / 16 / 18 / 22 / 28 / 32 swg ( xvii ) m s nuts & bolts of different size ( xviii ) galvanised nuts & bolts ( assorted size ) ( xix ) jointing sleeves ( alumnium ) suitable for 34 / 55 sq.mm ( xx ) jointing sleeves ( alumnium ) suitable for 70 100 sq.mm ( xxi ) jointing sleeves ( alumnium ) suitable for 150 232 sq.mm ( xxii ) anticlimbing device ( barbed wire ) 2x12 swg ( xxiii ) al paint ( xxiv ) red oxide paint ( xxv ) lt phase seperator ( xxvi ) 3 mm thick ms plate with weight of 0.36 kg asset tag ( xxvii ) transformer oil ( ehv grade ) ( xxviii ) natural ester oil ( xxix ) c wedge connector for 0.2sq panther conductor ( nominal aluminum area 200mm2 ) ( xxx ) fault locator machine for ug cables ( flc ) without vehicle ( xxxi ) transformer oil testing kit ( 220 / 230 ac ) ( xxxii ) transformer oil filter machine ( 500 gph ) ( xxxiii ) supply & installation of battery bank of 2 volt 300 ah vrla cells mounted on rack with insulated copper terminal connectors & nut boly ( each set of battery bank consist of 204 nos. vrla cells ) ( b ) furniture ( i ) thrive mid back revolving chair size:75cm ( w ) x 75cm ( d ) x 100cm 109cm ( h ) x 45cm 54cm ( seat height ) . ( ii ) thrive non revolving visitor chair size:63.5cm ( w ) x 59.5cm ( d ) x 97.5cm ( h ) x 42.5cm ( seat height ) . ( iii ) regency non revolving visitor chair with armrest size:59cm ( w ) x 63cm ( d ) x 81.5cm ( h ) x 45cm ( seat height ) . ( iv ) regency mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 78.5cm 90.5cm ( h ) x 44.2cm 54.2cm ( seat height ) . ( v ) bravo mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 85.5cm 97.5cm ( h ) x 42.5cm 54.5cm ( seat height ) . ( vi ) high back revolving chair size:76.1cm ( w ) x 76.1cm ( d ) x 114.5cm 131.5cm ( h ) x 44.5cm 54.5cm ( seat height ) . ( vii ) non revolving visitor chair size:60.9cm ( w ) x 64.7cm ( d ) x 98.2cm ( h ) x 46.2cm ( seat height ) . ( viii ) very high back revolving chair size:77cm ( w ) x 77cm ( d ) x 134.9cm 143.9cm ( h ) x 49.9cm 58.9cm ( seat height ) . ( ix ) non revolving visitor chair size:59cm ( w ) x 68.5cm ( d ) x 89.5cm ( h ) x 46.5cm ( seat height ) . ( x ) unlearn single seater cpu / laptop table for computer training hall size: 90cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xi ) unlearn 2 seater laptop table for meeting hall size:135cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xii ) unlearn 4 seater laptop table for meeting hall size:270cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xiii ) talk unitised 4 seater round table size:120cm dia x 75cm ( h ) ( xiv ) talk modular conference table size:67.5cm ( w ) x 60cm ( d ) x 75cm ( h ) ( xv ) enterprise table with cpu hanger size:165cm ( w ) x 90cm ( d ) x 72.8cm ( h ) ( xvi ) insight table for library size:180cm ( w ) x 90cm ( d ) x 74cm ( h ) ( xvii ) versatila v2 table for faculty sitting area size:150cm ( w ) x 89.4cm ( d ) x 75cm ( h ) ( xviii ) executive table with right unit and pedestal size:180cm ( w ) x 210cm ( d ) x 75cm ( h ) ( xix ) main desk table size: 180cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xx ) back unit for impress desk table size: 221.5cm ( w ) x 41cm ( d ) x 200cm ( h ) ( xxi ) display unit tv cabinet walnut color size: 140cm ( w ) x 40cm ( d ) x 75.4cm ( h ) ( xxii ) time out 4 seater pu coated dining table size: 113.5cm ( w ) x 117.5cm ( d ) x 75cm ( h ) ( xxiii ) café chair without armrest size: 52.5cm ( w ) x 55.8cm ( d ) x 84.5cm ( h ) x 45cm ( seat height ) ( xxiv ) apple dining table 6 seater glass top size: 160cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xxv ) silver dining chair size: 44.5cm ( w ) x 41.5cm ( d ) x 96cm ( h ) ( xxvi ) dark walnut dining chair size: 45cm ( w ) x 45cm ( d ) x 95cm ( h ) ( xxvii ) coffee table walnut color size: 100cm ( w ) x 65cm ( d ) x 45cm ( h ) ( xxviii ) 3 seater leatherite sofa size: 205.5cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxix ) 2 seater leatherite sofa size: 100cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxx ) single seater leatherite sofa size: 86cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxxi ) plain almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxii ) glass door storwel almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxiii ) single sided wood & steel book rack base unit size:90cm ( w ) x 30cm ( d ) x 189cm ( h ) ( xxxiv ) all steel periodical display rack size:90cm ( w ) x 45cm ( d ) x 183cm ( h ) ( xxxv ) 4 door bookcase ( without top ) size:91.4cmw x 32cm ( d ) x 174.2cm ( h ) ( xxxvi ) white board 4ft. x 3ft. with stand ( xxxvii ) l shaped workstation made of 19mm thk white mdf board with pvc edges.size:1800mm ( l ) + 1200mm ( l ) x 600mm ( d ) x 1200mm ( h ) meter box ( i ) poly carbonate weather proof outdoor type meter cover boxes for single phase meter size 315mm x 265mm x 130mm along with zinc plated clamps ( ii ) poly carbonate weather proof outdoor type meter cover boxes for three phase meters 445mm x 345mm x 170mm along with zinc plated clamps ( iii ) deep drawn m.s. sheet weather proof outdoor type meter cover box for single phase meter size 300mm x 250mm x 160mm along with zinc plated clamps ( iv ) deep drawn m.s. sheet weather proof outdoor type meter cover box for three phase meter size 500mm x 300mm x 160mm along with zinc plated clamps ( v ) metal box of ct 800 / 5 amp ( vi ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 400 / 5a ( vii ) meter box ( viii ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 800 / 5a ( ix ) metal box of ct 400 / 5 amp gas insulated switchgear s / s ( i ) 30kv, 10ka, metal oxide, station class, surge arrester ( scada compliant ) ( for 33kv incoming line, ht side of 2nos. power transformers and 33 / 0.433kv station transformer ) outdoor type with surge counter. ( ii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) with: breaker: 36kv, 1250 a, ( 25ka s.c. rating ) , 3 ph, indoor type breaker ( with 30v dc tripping / closing coil and associated control ) along with marshalling box, terminal connectors and required accessories complete as per applicable ts ct:36kv, 1 ph, 25ka ( 800^00 200 / 1 1 1 a ) indoor type current transformer, having three secondary cores ( protection & metering & current differential protection ) along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set = 3 nos. ) pts: 36kv, 1 ph, 33kv / 110 v, single core outdoor type potential transformer along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set= 3 nos. ) and digital ammeter / voltmeter / energy meter, o / c and e / f relay etc. the cable chamber shall have 3 nos., 20kv, 10 ka distribution class valve type lightning arresters and isolators of capacity given in ts. for feeder protection ( iii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between gis and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for bus coupler protection. ( iv ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 1a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between breakers and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for power transformer protection. ( v ) 11 kv indoor gas insulated switch gear panel ( scada compliants ) consisting of 1250 a, 25ka for 3 seconds, 3 ph, indoor type breaker along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for transformer protection ( vi ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for bus coupler protection ( vii ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for feeder protection ( viii ) remote terminal unit ( rtu ) & accessories with pc & connections with 30 nos. analog points for voltage, frequency, mw, mvar ; 3 positional analog points for oltc and 28 digital points for breaker and isolator status. ( ix ) flexible cu. earth bond 1cm dia & 500mm long, both end provision of socket suitable for m 16 bolts. ( x ) g 3 gi beam ( 5.05mtr long, consisting of 2 nos 150x75 x5.7mm ) for 33kv incoming line ( 2 nos. beam one for surge arrester and other for isolator, nominal unit wt 0.2 mt ) ( xi ) gi spikes with cone and gi ( 2 nos ) base plate 10mm ( 50x2500 mm gi pipe ) ( unit wt=0.04 mt ) ( xii ) 12 kv, 630 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , gang operated isolator along with earth switch and support insulators, operating mechanism, base channel, down pipe and all required accessories complete as per technical specifications, without earth switch for substation transformers. ( xiii ) 60 kg / mtr rail pole pieces 5.4 mts ( 2.7x2 ) 44.62 kg per mtr / transformer ( unit wt=0.240 mt ) ( xiv ) 2 tier 2 rows cable trench ( internal width 1500 mm, depth 680 mm, width 75x75x6 mm support angles fixed rcc column of 250 x 250 mm & with ladder type cable tray ( 45x45x5mm two angles at both side having welded flats of 25x5 mm at a gap of 150mm ) for power & control cable ( xv ) chequerred plate 1000x300x5.6mm thick for cable trench in side control room 12 mtr ( xvi ) overhead hoist beam mounted remote opertated for lifting of equipment of control room, capacity 5 tonnes ( xvii ) 36kv, 800 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , motorised indoor floor mounted off load isolator along with all required accessories complete as per technical specifications, scope of works and approved ( xviii ) external electrification in switch yard area including power receptacles, station yard lighting with 6 nos lighting pole ( fitted with 2x100 watts led flood light ) made of 11 meters high steel tubular poles ( is 2713 part i, ii iii ) of designation 410 – sp 60 and 6 nos light ( 1 x 250 w led ) on structure & control room complete as per technical specifications, approved drawings and scope of the work. ( xix ) internal electrification works of control room comprising of main distribution board, sub distribution boards, copper flexible multi conductor 2.5 sqmm wiring ( for light & fan ) / 4 sqmm wiring ( for power points ) , power and light points, conduits, fan / led lamps / tube fittings, exhaust fans, switches, sockets, 2mm thick, pvc 25mm dia conduits pipes in recess, plugs, miniature circuit breakers, seperate independent earthing ( 2 nos of 40mm gi pipe / 3 m long ) etc as required including dc emergency lighting and auto change over switch as per technical specifcations, approved drawings and scope of work. over head distance to fault locator ( offline ) with signature analyser. a ) accessories & laptop as per latest technical specifications tower line for river crossings ( i ) d type tower for 33kv, 11kv ( double circuit line ) ( 13.56mt each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( ii ) d type tower for 33kv, 11kv ( four circuit line ) ( 15.14mt ) ( double circuit tower +3meter extension each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( iii ) compression type tension hardware fitting for earth wire ( iv ) vibration damper suitable for 7 / 3.15 mm gi earth wire ( v ) 25x500 mm flexible cu. earth bond. covered conductor & accessories ( i ) acsr covered panther conductor ( 200 sq. mm ) ( ii ) acsr covered wolf conductor ( 150 sq. mm ) ( iii ) acsr covered dog conductor ( 100 sq. mm ) ( iv ) mid span joint ( 150 sq mm & 200 sq mm ) ( v ) suspension ties ( ( 150 sq mm & 200 sq mm ) ) ( vi ) tension clamp ( wedge type ) ( ( 150 sq mm & 200 sq mm ) ) ( vii ) insulation piercing connector ( bare to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( viii ) insulation piercing connector ( covered to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( ix ) insulation piercing connector with alumunium bail for earthing ( ( 150 sq mm & 200 sq mm ) ) ( x ) mid span joint ( 100 sq mm & 50 sq mm ) ( xi ) suspension ties ( ( 100 sq mm & 50 sq mm ) ) ( xii ) tension clamp ( wedge type ) ( ( 100 sq mm & 50 sq mm ) ( xiii ) insulation piercing connector ( bare to covered ) ( 100 sq mm & 50 sq mm ) ( xiv ) insulation piercing connector ( covered to covered ) ( 100 sq mm & 50 sq mm ) ( xv ) insulation piercing connector with aluminium bail for earthing ( 100 sq mm & 50 sq mm ) led lights and related items ( i ) led light 190w ( ii ) led light 120w ( iii ) led light 75w ( iv ) led light 40w ( v ) 18 watt led panel bulb with outer 205x205x25 mm sq. and 180x180 mm inner diesel generator sets ( three phase ) with amf panel ( i ) 10kva ( ii ) 20kva ( iii ) 30kva ( iv ) 40kva ( v ) 50kva ( vi ) 62.5kva ( vii ) 82.5kva ( viii ) 100kva ( ix ) 160kva trw related items ( i ) 1 / 2 l.t. brass studs ( ii ) 1 / 2 h.t. brass studs ( iii ) l.t bushing 3347 250 amp ( iv ) l.t. bushing 250 amp ( v ) kraft paper 4 mile ( vi ) insulating paper tap 2.0 mm ( vii ) press board 1 mm ( viii ) bakelite tube 3 / 8x1 / 2 ( ix ) empire sleeving size 4 mm ( x ) r.c. sheet 3 x2x1 / 2 mm ( xi ) inline connector 6 mm ( xii ) cotton tap 1 ( xiii ) r.c. strip ( xiv ) r.c. washer 50x28x2 ( xv ) silicagel breather 200 kva ( xvi ) m.seal ( xvii ) c.i.cap 1 8 1 / 2 ( xviii ) insulating paper top 2.5 mil 20 mm ( xix ) crap paper ( xx ) g.p. thinner ( xxi ) d.a. gray paint ( xxii ) white paint ( xxiii ) nylon washer 3 / 4 ( xxiv ) m.s. plug ( xxv ) l.t. al.strip 6.50x4.50 mm ( xxvi ) dpc aluminum winding wire ( xxvii ) dpc aluminum winding strip ( xxviii ) transformer testing bench panel for 10 kva to 500 kva distribution transformer with its installation & commissioning transformer repairing items ( i ) l.t bushing rod assembly of 750 kva transformer. ( ii ) h.t bushing rod assembly of 750 kva transformer. ( iii ) l.t bushing insulator of 750 kva transformer. ( iv ) h.t bushing insulator of 750 kva transformer. ( v ) l.t bushing gasket set of 750 kva transformer. ( vi ) h.t bushing gasket set of 750 kva transformer. ( vii ) tank gasket set of 750 kva transformer. ( viii ) silica gel breather of 750 kva transformer. ( ix ) arching horn of 750 kva transformer, ( x ) l.t bushing rod assembly of 500 kva transformer ( xi ) h.t bushing rod assembly of 500 kva transformer ( xii ) l.t bushing insulator of 500 kva transformer ( xiii ) h.t bushing insulator of 500 kva transformer ( xiv ) l.t bushing gasket set of 500 kva transformer ( xv ) h.t bushing gasket set of 500 kva transformer ( xvi ) tank gasket set of 500 kva transformer ( xvii ) silica gel breather of 500 kva transformer ( xviii ) arching horn of 500 kva transformer ( xix ) l.t bushing rod assembly of 400 kva transformer ( xx ) h.t bushing rod assembly of 400 kva transformer ( xxi ) l.t bushing insulator of 400 kva transformer ( xxii ) h.t bushing insulator of 400 kva transformer ( xxiii ) l.t bushing gasket set of 400 kva transformer ( xxiv ) h.t bushing gasket set of 400 kva transformer ( xxv ) tank gasket set of 400 kva transformer ( xxvi ) silica gel breather of 400 kva transformer ( xxvii ) arching horn of 400 kva transformer ( xxviii ) l.t bushing rod assembly of 315 kva transformer ( xxix ) h.t bushing rod assembly of 315 kva transformer ( xxx ) l.t bushing insulator of 315 kva transformer ( xxxi ) h.t bushing insulator of 315 kva transformer ( xxxii ) l.t bushing gasket set of 315 kva transformer ( xxxiii ) h.t bushing gasket set of 315 kva transformer ( xxxiv ) tank gasket set of 315 kva transformer ( xxxv ) silica gel breather of 315 kva transformer ( xxxvi ) arching horn of 315 kva transformer ( xxxvii ) l.t bushing rod assembly of 250 kva transformer ( xxxviii ) h.t bushing rod assembly of 250 kva transformer ( xxxix ) l.t bushing insulator of 250 kva transformer ( xl ) h.t bushing insulator of 250 kva transformer ( xli ) l.t bushing gasket set of 250 kva transformer ( xlii ) h.t bushing gasket set of 250 kva transformer ( xliii ) tank gasket set of 250 kva transformer ( xliv ) silica gel breather of 250 kva transformer ( xlv ) arching horn of 250 kva transformer ( xlvi ) l.t bushing rod assembly of 200 kva transformer ( xlvii ) h.t bushing rod assembly of 200 kva transformer ( xlviii ) l.t bushing insulator of 200 kva transformer ( xlix ) h.t bushing insulator of 200 kva transformer ( l ) l.t bushing gasket set of 200 kva transformer ( li ) h.t bushing gasket set of 200 kva transformer ( lii ) tank gasket set of 200 kva transformer ( liii ) silica gel breather of 200 kva transformer ( liv ) arching horn of 200 kva transformer ( lv ) l.t bushing rod assembly of 100 kva transformer ( lvi ) h.t bushing rod assembly of 100 kva transformer ( lvii ) l.t bushing insulator of 100 kva transformer ( lviii ) h.t bushing insulator of 100 kva transformer ( lix ) l.t bushing gasket set of 100 kva transformer ( lx ) h.t bushing gasket set of 100 kva transformer ( lxi ) tank gasket set of 100 kva transformer ( lxii ) silica gel breather of 100 kva transformer ( lxiii ) arching horn of 100 kva transformer ( lxiv ) l.t bushing rod assembly of 63 kva transformer ( lxv ) h.t bushing rod assembly of 63 kva transformer ( lxvi ) l.t bushing insulator of 63 kva transformer ( lxvii ) h.t bushing insulator of 63 kva transformer ( lxviii ) l.t bushing gasket set of 63 kva transformer ( lxix ) h.t bushing gasket set of 63 kva transformer ( lxx ) tank gasket set of 63 kva transformer ( lxxi ) silica gel breather of 63 kva transformer ( lxxii ) arching horn of 63 kva transformer ( lxxiii ) l.t bushing rod assembly of 25 kva transformer ( lxxiv ) h.t bushing rod assembly of 25 kva transformer ( lxxv ) l.t bushing insulator of 25 kva transformer ( lxxvi ) h.t bushing insulator of 25 kva transformer ( lxxvii ) l.t bushing gasket set of 25 kva transformer ( lxxviii ) h.t bushing gasket set of 25 kva transformer ( lxxix ) tank gasket set of 25 kva transformer ( lxxx ) silica gel breather of 25 kva transformer ( lxxxi ) arching horn of 25 kva transformer ab switch repairing item ( i ) jaw of air break switch 600a ( ii ) blade of of air break switch 600a ( iii ) post insulator of air break switch 600a ( iv ) bearing of air break switch 600a ( v ) phase coupling pipe of air break switch 600 a ( vi ) down pipe of air break switch 600 a ( vii ) operating handle of air break switch 600 a ( viii ) operating leaver of air break switch 600 a ( ix ) connector of air break switch 600 a ( x ) arching horn of air break switch 600 a ( xi ) jaw of air break switch 400a ( xii ) blade of of air break switch 400a ( xiii ) post insulator of air break switch 400a ( xiv ) bearing of air break switch 400a ( xv ) phase coupling pipe of air break switch 400 a ( xvi ) down pipe of air break switch 400 a ( xvii ) operating handle of air break switch 400 a ( xviii ) operating leaver of air break switch 400 a ( xix ) connector of air break switch 400 a ( xx ) arching horn of air break switch 400 a ( xxi ) jaw of air break switch 200a ( xxii ) blade of of air break switch 200a ( xxiii ) post insulator of air break switch 200a ( xxiv ) bearing of air break switch 200a ( xxv ) phase coupling pipe of air break switch 200 a ( xxvi ) down pipe of air break switch 200 a ( xxvii ) operating handle of air break switch 200 a ( xxviii ) operating leaver of air break switch 200 a ( xxix ) connector of air break switch 200 a ( xxx ) arching horn of air break switch 200 a vcb repairing item ( i ) trip coil of 33kv vcb ( ii ) trip coil of 11kv vcb ( iii ) closing coil of 33kv vcb ( iv ) closing coil of 11kv vcb ( v ) push button switch 5a ( vi ) test terminal block 5a ( vii ) 33 kv indoor current transformers of ratio as required suitable for metering and protection. ( viii ) 33 kv outdoor current transformers of ratio as required suitable for metering and protection. ( ix ) 11 kv indoor current transformers of ratio as required suitable for metering and protection. ( x ) 11 kv outdoor current transformers of ratio as required suitable for metering and protection. ( xi ) 33000 / 110 volts single phase voltage transformer indoor. ( xii ) 33000 / 110 volts single phase voltage transformer outdoor. ( xiii ) 11000 / 110 volts single phase voltage transformer indoor. ( xiv ) 11000 / 110 volts single phase voltage transformer outdoor. ( xv ) flush type switchboard mounting pattern 96x96 sq.mm m.i. voltmeter ( xvi ) voltmeter phase selector switch. ( xvii ) indicating lamps coloured red, amber and blue, white, green, etc. ( xviii ) auxiliary switch having minimum of 8 contacts, 4 normally open and 4 normally closed ( xix ) flush mounting pattern 96x96 sq.mm m.i. ammeter ( xx ) ammeter selector switch to indicate phase current ( xxi ) over current and earth fault numerical relay ( xxii ) automatic door illuminating lamps with switch ( xxiii ) 240 v, 100 w, ac single phase anti / condensation heaters, with thermostat ( 0 60 deg. c ) and switch. ( xxiv ) operation counter for vcb ( xxv ) bus bar spout epoxy casted r phase of 33kv indoor vcb ( xxvi ) bus bar spout epoxy casted y phase of 33kv indoor vcb ( xxvii ) bus bar spout epoxy casted b phase of 33kv indoor vcb ( xxviii ) circuit spout epoxy casted of 33kv indoor vcb ( xxix ) housing for vacuum interrupter of 33kv indoor vcb ( xxx ) drive insulator 33kv vcb ( xxxi ) release coil of 33kv indoor vcb ( xxxii ) bus bar spout epoxy casted r phase of 11kv indoor vcb ( xxxiii ) bus bar spout epoxy casted y phase of 11kv indoor vcb ( xxxiv ) bus bar spout epoxy casted b phase of 11kv indoor vcb ( xxxv ) circuit spout epoxy casted of 11kv indoor vcb ( xxxvi ) housing for vacuum interrupter of 11kv indoor vcb ( xxxvii ) drive insulator of 11kv vcb ( xxxviii ) release coil of 11kv indoor vcb ( xxxix ) vacuum interrupter of 33kv outdoor type ( xl ) vacuum interrupter of 33kv indoor type ( xli ) vacuum interrupter of 11kv outdoor type ( xlii ) vacuum interrupter of 11kv indoor type ( xliii ) buzzer / hooter ( xliv ) t n c switch mrt related items ( i ) fully automatic energy meter test bench with 0.02 class, 10 position, for testing of 1 ph & 3 ph energy meters with 5 years maintenance, accreditation from nabl and software updation. ( ii ) instrument transformer ( ct pt ) test system ( iii ) transformer turn ratio meter and measurement test kit ( iv ) transformer oil filtering machine 500 gph ( v ) circuit breaker operational analyzer ( vi ) 3 ph relay test kit with all necessary accessories ( vii ) primary injection kit 1000 a with relay testing facility ( viii ) ht coil winding machine its installation, testing & commissioning ( ix ) lt coil winding machine its installation, testing & commissioning ( x ) 03 ( three ) phase transformer winding resistance meter ( xi ) digital multimeter, 750v ( xii ) capacitance tan delta test set for transformer, motor and switchgear ( xiii ) capacitance tan delta test set for cables ( xiv ) vaccum interrupter tester ( xv ) secondary injection kit ( xvi ) digital ht earth tester ( xvii ) 3 ph power quality analyser ( xviii ) 05 kv insulation tester ( manual ) ( xix ) 10 kv insulation tester ( motarized ) ( xx ) digital clamp meter; 20 1000a, 200 v dc ( xxi ) digital clamp meter; 20a ( 1ma 20a ) ( xxii ) discharge rod ( make fibre ) ( xxiii ) thermal imaging camera ( xxiv ) single phase & three phase meter automatic testing bench for 20 positions ( 0.02s class rsm ) frp fencing ( i ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 63 / 100 / 200 / 500 kva substation etc...

Drinking Water And Sanitation Department - Jharkhand

31897243 e quotation for seeking firm rates for non schedule items for preparing estimates. gr c repairing of electro mechanical assets and all their associate works like repairing of motors, pumps, starters, panel, cables etc. at rinpas, kanke, ranchi , c / f pump sets , cost towards dismantling of 100 hp wpil make single stage c / f pump and taking out its rotating unit assembly with changing of damaged parts by new making s / f neck ring as per sample size 2 nos, c.i shaft sleeve as per sample size – 2nos, making s / f shaft sleeve check nut as per sample size – 2 nos , s / fball bearing skf 6309 2 nos and repairing of bearinghousing by welding turning machining as per bearing size 2 nos, c.i gland tightner as per sample size – 2nos including cost of reassembling of rotating unit assembly balancing rotating unit assembly and fitting the pump with supply of grease gland packing oil packing paper with transporting cost of rotating unit from p / plant to workshop and back , cost toward supplying fitting & changing of 100 hp jyoti make motor ball bearing skf 6316 at de side 1 no. and sk 6314 nde 1 no. with grease. , cost towards repairing of 100 hp l & t make f.a.s.d starter with s / f contactor set 2 sets ) , relay unit ( 85 135a ) 1set, timer unit 1 set, making new connection etc all complete. , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 100 hp pump set. , cost towards supplying and fitting mccb 630 amp. for bus bar make l&t schneider / bch , cost towards supplying and fitting mccb 250 amp. for bus bar make l&t schneider / bch , cost toward supplying fitting & changing 100mm dia cidf sluice valve ( pn 1 ) 1 set & cidf nr valve ( pn 1 ) 1 no. including fitting charge , cost toward supplying fitting & changing 150 mm dia ci foot valve hiding single leather flat and gun metal seating all complete. , cost towards providing all labours tools & techniciansfor dismantling and disconnecting of 40 hp kirloskar make motor and taken out rotor from motor stator cutting removing burnt and damaged coil and after repairing refitting the same etc all complete. , cost towards full rewinding of 40 hp motor stator with supplying of super enameled round copper conductor suitable gauge class f insulating materials making all connection taping, varnishing with dr beck varnish all complete with deducting the cost of taken out scrap materials ( wt. of wire is 18.5kg approx ) . , s / f ball bearing skf make 6312&6309 at de&nde side of 40 hp kirloskar make motor including proper greasing all complete. , cost towards providing all labour tools and tackles for dismantling of 40 hp single stage kirloskar make c / f pump with changing damaged parts such as gm neck ring as per size and sample 2 nos. shaft sleeve 2 nos. shaft sleeve check nut 2 nos. making ci bearing housing as per size and sample 2 nos. supplying and fitting ball wearing skf make 6309 2nos. making supplying and fitting ms gland tightner as per size and sample 2 pair making citric motion of rotating unit assembling on lathe m / c etc all complete , cost towards repairing of 40 hp l&t motor starter by supplying and fitting l&t make 3 core ml 4 power contactor 45 amp. with auxiliary contractor complete set 2nos. supplying and fitting timer type lt 100 1nos., over load relay suitable range 1nos.etc all complete. , cost towards providing all labours tools & technicians for taking out damaged 250amp. tpn hrc fuse type disconnector main switch replacing new disconnector fuse unit with hrc fuse 1 set doing electrical connection and testing on full load after deducting the cost of taken out scrap materials , supplying and fitting 6”dia tyre coupling complete set with nut bolt washer and tyre of reputed make for 40 hp pump set. , cost towards providing all labour tools and tackles for dismantling and taken out damaged nr valve and s / f 4”dia c.i df nr valve heavy duty rating pn 1 isi marked on delivery pipe line with all work including cost of labour charge all complete testing on full load with deducting the cost of scrap materials. , cost towards supplying and laying 50 mm² x 3.5 core aluminium armoured cable from main switch to industrial panel. ( both sets ) . , cost towards supplying and laying 16 mm² x 3 core copper cable from panel to starter and starter to motor in bunch of two. ( both sets ) . , cost towards replacing damaged suction pipe by making supply & fitting 100 mm dia heavy duty m.s. suction pipe 10feet long both and 100 mm dia m.s. flange welding, 100mm dia long bend 1 no with nut bolt rubber insertion etc required for the job. , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge. , submersible pump sets , cost towards providing all labour tools and technicians for dismantling and taken out 5hp submersible p / set with column pipe for bore well. , cost towards for rewinding and repairing of5 hp submersible motor with s / f 1.2 swg round copper winding wire 24 slot, gun metal bush, thrust plate, thrust bearing, diapharm, oil seal, etc with lathe work. all complete. after the deduction of cost of scrape materials. , cost towards repairing of5 hp submersible pump with s / f norylimpeller as per size and sample, diffuser, s.s. shaft, s.s. coupling, s.s. sleeve, nut, c.i. suction casing, c.i nrv etc. all complete ( 23 stage ) after the deduction of cost of scrape materials. , cost towards s / f and changing of 2”dia upvc column pipe with heavy duty socket ( make supreme / paras ) for both sets. , cost towards replacement of damaged submersible cable by supplying and fitting 4 mm2x 3 core flat submersible cable including cable jointing all complete. after the deduction of cost of scrape materials. dwsd m1062 , providing all labour, tools tackles& technicians for lowering of 5hp submersible pump set with all accessories in the bore well , cost towards supplying and fitting ( 1 ) 50 mm dia g.m. full way valve – 1 no ( 2 ) 40 mm dia nr valve – 1 no ( 3 ) 40 mm dia g.i. bend ( 4 ) 2” dia m.s. clamp with nut bolt 2 pair after the deduction of cost of scrape materials. , supplying and installation suitable size panel board for 5 hp submersible pump including fixing on wall comprising of following points such as ( 1 ) d.o.l starter 1no. ( 2 ) hrc fuse – 3 no. ( 3 ) voltmeter with selector switch – 1 set ( 4 ) ammeter with selector switch – 1 set ( 5 ) phase indicating neon lamp – 3 nos. etc. all complete after the deduction of cost of scrap materials. , supplying all material such as 40 mm dia g.i. pipe medium quality 15 ft. long, charcoal salt etc. for making earthing station as per i.e. rule , supplying and laying ground and on wall 10 swg, g.i. wire for doing continuous earthing for all electrical equipments , cost towards replacement of old and damaged underground service line by supplying new overhead line 10 mm² 3core copper wire after the deduction of cost of scrap materials. , supplying and laying ( under and over ground ) 2 dia aqua gold weather proof pvc pipe from bore well to main rising pipe line ( damaged pipe replacement ) make supreme / isi mark ( both sets ) , supplying and laying 1.5 dia under and over ground supreme aqua gold / any reputed make weather proof upvc pipe from bore well to dharamshala over head tank. , supplying and fitting union 1.5 dia , supplying and fitting elbow 1.5 dia , supplying and fittingtee 1.5 dia , supplying and fitting socket 1.5 dia , supplying and fitting upvc valve 1.5 dia , transportation charge of above p / set from work site to work shop and vice versa including loading and unloading charge....