Health Department - Jharkhand

39468392 supply for office stationery , items name , heavy duty stapler ds 23s24fl( i s imark) , stapler hp – 45 plier, 24/6 26/6( i s imark) , led flood light 50 w , led flood light 100 w , led bulb 23 w , led bulb 15 w , led bulb 9 w , stapler pin small , stapler pin big , table lamp large , pencil battery , fly leaf file with office namestandard with cloth cover , standard , c.l registered printed , weight machine digital , d.f paper , , flag file sticker , whitener/correction pen ( fabercastle) , fancy register 2 quire , fancy register 3 quire , fancy register 4 quire , fancy register 5 quire , staplerfiber hs 10 , attendance register – 1q , attendance register – 2 q , dispatch register – 4q , paper clips ( plastic ) , penstand with 4 pen , led bulb 40 w , table cloth¼ jsdflu ½ , whitener/correction pen ( faiber castle) , eraser ( 12 pics ) , pencil cutter ( 12 pics ) , laser jet m 1005 mfp catridge , fevi sticks ( big ) , cello tap 1’’ ( transparency) , cello tap 2’’ ( transparency) , cello tap 3’’ ( transparency) , punching machine ( kangaroo) , tray medium , harpic ( 500 ml) , odonil 50 g , colin 500ml , pen drive ( 16 gb) , pen drive ( 32 gb) , , premium paper board cover file , ceiling fan , gourd file , betary water ( 5 ltr) , acid (1ltr) , lock 7 lever ( link ) , call bell ( battery ) , call bell ( electric) , 5 amp socket , 5 amp swtich , 5 amp top ( plug ) , 15 amp top ( plug ) , blub holder , table glass3x 4.6 fit , window colth 3x6 fit , door colth 3x 7 fit , wall watch , electric wire 1.5 mm , electric wire 2 mm , electric wire 2.5 mm , electric wire 3.20 mm , electric wire 5.mm , electric wire 7/20mm , electric wire 10 mm , weight machine general , ac copper wire per feet , ac ( 1.5 ton ) gas , ac ( 2 ton ) gas , wall fan , plastic folder , writing pad ( genral ) , writing pad ( spiral ) , marker pen for pulse polio , bathroom squeegee plastic wiper with telescopic handle (30 cm) , clip n fit cotton floor mop with plastic handle , heavy duty extension board (6+6) 1.5mm 3 core heavy wire , 12 disit basic desktop calculator , 1000 ml stainless steel water bottle , jps electric kettle stainless steel 1500 watt 1.8 litre tea coffee maker water boiler with handle,1500 watts,1.8 liter , tea cup set, 6 with tray , clear glass (300 ml 6 pcs set) , room freshener (rose & sandal flavour) , water bottle , door mat office size 40x60cm , double side foam tape 2 inch width,48mmx5 mtr set of 2...

Rajendra Institute Of Medical Science - Jharkhand

39466584 supply of chemical items at rims, ranchi , name of chemical goods , 20*c mini cooler (it should be made up of polycarbonate and non toxic gel, must contain atleast 12 places for 1.5ml tube. ) , 0.1 gparacetic acid other ingredients : corrosion inhibitors, surfactants, stabilising agents, excipients. hydrogen peroxide, acetic acid passes en 13624, en 13727, en 14348, en 14347, en 14476 standards, pack size: 5 litre jar , 0.5 % w/v chlorhexidine gluconate and 70 % v/v ethanol , 1% w/v available iodine in nonoxynol iodine surfactant500 ml , 1*tae buffer , 1,4 dithiotreytol (dtt) ()solid (powder) 25 gm , 100 g of gigazyme x tra contains: 7.7 g didecyldimethylammonium chloride, 0.4 g of polyhexamethylene biguanide (monomer: 1,5 bis(trimethylen) guanylguanidinium monohydro chloride) (phmb) contains subtilisin tridecylpolyethylenglycolether propan 2 ol, glycerol passes en 13624, en 13727, en 14561 and en 14562 standards, pack size: 2 litre bottle , 2* ab enzymatic reaction stop solution h2so4 paraformaldehyde glutaraldehyde solution,25% w/w 1 gm , 2.45% w/v glutaral dehyde with a powder activator completely free of surfactants 5ltrs , 20 40% phosphoric acid based scale remover ltr. , 2 mercaptoethanol (? me) liquid 100 ml , 2 methoxy ethanol (250mg) (purity (gc) > 99.75 %) , 2 propanol ip: 45 g / isopropanol, 1 propanol: 30 g /n propanol ethyl hexadecyl dimethyl ammonium ethylsulphate: 0.2 g emollient and moisturiser with skin protecting substances 500 ml bott with dispenser passes en 13727, en13624, en14476, en1500, en12791 standards, pack size: 500 ml bottle , 4 methylumbelliferone (100gm)(purity (hplc) =98 %, mol. wt 198.2) , 4 methylumbelliferyl ? d glucopyranoside (25mg)(to be used in prenatal diagnosis, analytical grade) , 4 methylumbelliferyl ? d galactopyranoside (1gm )(=99% (tlc)) , 4 methylumbelliferyl ? d galactopyranoside 6 sulfate sodium salt (5gm) (hplc purified, =90%) , 4 methylumbelliferyl 6 sulfo n acetyl ? d glucosaminide, potassium salt (25mg) (to be used in prenatal diagnosis, analytical grade) , 4mu beta d glucopyranoside (250mg)(purity (hplc) > 99 %) , 4 mu alpha d gluco pyronoside (100mg) (purity (tlc) > 99 %) , 50x tae 500 ml , 60%v/v ethyl alcohal with benzalkonium chloride, glycerine, dimethiconecyclopentasiloxane, c12 15 alkyl lactate, proylene glycol, methylparaben, phenoxythanol, stearyl alcohol, aminomethyl propanol, diazolidinyl propanol,diazolidinyl aurea with moisturizer 500 ml , 6 mercaptohexanoic acid (1gm)(laboratort reagent grade, 90.0%) , 7 colour setup 1000 pcs , a.s.o. titre (rapid test kit) 100 test , absolute acid 500 ml , absolute alcohol 2.5 ltrs should be 99.9 % boiling point = 78.3°c ( 1013 hpa) melting point = 117°c density = 0.7895 gm/cm3 ( 20°c ) flash point = 12°c ( closed cup ) ethanol content percent by volume at 15.6°c = 99.50 alkalinity = nil acidity as acetic acid percent by weight = max. 0.006 ( 60 ppm) residue on evaporation percent by weight = max. 0.005 ( 50 ppm ) copper as gm/100ml = max. 0.0004 ( 4 ppm ) ester as ethyl acetate gm/100ml = max. 0.02 ( 200 ppm ) aldehyde as acetaldehyde gm/100ml = max. 0.01 ( 1000 ppm ) , absolute alcohol 500 ml , ace control level 1 100 ml , acetamide agar 500 gm , acetic acid 500ml ( laboratory chemical ) only for industrial, institutional and research purposes, not for drug , acetic acid 2.5 ltrs , acetic acid 200 ml , acetic acid 250 ml , acetone 25 ml , acetone 5 l mol. wt. = 58.08 gm/mol density = 0.7845 gm/cm3 melting point = 94.7°c boiling point = 50.05°c smell = fruity , acetone 500 ml , acetonitrile (ico grade) liquid 100 ml , acid based liquid neutralizer concentrate to be used with dosing pump.nos. , acid fuchsin 1% 100 ml , acid fuchsin solid (powder) 25 gm , acid glycoprotein 100 gm , acid orthophoaphoric 500 ml , acid phosphatase 10x2ml , acp 100 ml , acrylic cold curve liquid 500 ml , acrylic cold curve powder 250 gm , acrylic colours 500ml a. black b. dark green c. maroon d. ultramarine blue can be used on variety of surfaces. stays permanent on paper earth ware, wood, thermocot, stone etc., wash proof rich in colour value, quick drying and ready to use and requires no separate medium , actidione with agar 500 gm , activated charcol 500 gm , ada control 100 ml (compactible with dirui cst240) , ada enzymetic 25ml , ada with calibrator 100 ml (compactible with dirui cst240) , adenovirus, stool, antigen, premiere adenoclone, ridascreen; r.biopharma , adrenaline hydrochloride 500ml , af media 100ml bottle (ready to use, media should contains fetal bovine serum (fbs), gentamicin, and l glutamine.) , afp 1 ml , afst disc fluconazole amphotericin itraconazole 100 disc , agar powder 500 gm , agarose 500 gm , agarose powder 250gm(to be used for nucleic acid separation, tested dnase and rnase free, high grade) , ahg 5 ml , albert’s stain – a – 250 gm each , albert’s stain – b – 250 gm each , albumin bcg 100 ml , albumin kit 3x150ml , alcian blue 500ml , alcian blue 8gx 100 ml , alcian blue satain ( ph 2.5, 100ml/ pack size) , alcian blue solid (powder) 5 gm , alcohol 90% 2 ltrs , alcohol ethyl 500ml , aliquote cup (centrifuge tab 1.5 ml) 500 pc , alizarin red s 100 ml , alkalian blue 100 ml , alkaline peptone water 25 x 5 ml , alkaline phosphatase kit 20x15ml , alkyl alcohol ethoxilate 20 40%, sodium benzoate, 5% based emulsifier ltr. , alkyl dimethyl benzyl ammonium chloride (in house) (2.37 %) alkyl dimethyl ethyl benzyl ammonium chloride (in house) (2.37 %) inert ingredients (95.26 %) , alkyle dimethyle benzile ammonium chloride (in house) (2.37%) inert ingrediets 95.26% , alp 100 ml , alpha nepthyl butyrate 500 ml , alt (sgpt) 2x150ml , altl/sgpt 2x150 ml , aluminium ammonium sulphate 500 ml , aluminium foil each pack , aluminium potassium sulphate [ potash alum] f. wt. = 474.39 assay nlt = 99.0% ph (10% solution at 20°c) = 3.0 4.0 chloride ( cl ) nmt = 0.0005 ammonia ( nh4 )nmt = 0.005% iron (fe)nmt = 0.005% lead (pb)nmt = 0.0005 % , amacr 1 ml , amdinocillin 10 mcg , amh elisa kit 96 tests , amikacin (antibiotic disc)30mcg (250 disc) , amikacin(antibiotic disc) 10 mcg (250 disc) , ammonia solution 2.5 ltrs about 25% m = 17.03 g/mol ( 1l = 0.90 kg ) specification: assay ( nh3 ) = 25 % non volatile substance = 0.002 % , ammonia solution extrapure ar, 25% liquid 500 ml , ammonium acetate solid (powder) 100 gm , ammonium chloride 500 gm , ammonium citrate – 500 ml , ammonium hydroxide 500 ml , ammonium molybdate 100 gm , ammonium molybdate 500 gm , ammonium oxalate 250gm , ammonium oxalate 500ml , ammonium persulphate, solid (powder) 25 gm , ammonium solution 500 ml , ammonium sulfonate 500g bottle (acs reagent, 99.0 100.5%) , ammonium sulphate 250 gm , ammonium sulphate 500 gm assay = 98.5 % nvm = 0.2 % chloride = 0.005 % iron = 0.002 % lead= 0.002 % 10 % aqueous solution clear and colourless specification: specific rotation ( [ ? ] 20°/d; c = 10 water ) = +51 to +53° melting range = 145°c 150°c chloride = 0.005 % sulphate = 0.01 % sulphites = passes test arsenic = 0.0001 % iron = 0.0005 % heavy metals ( as pb ) = 0.0005 % loss on drying ( 105°c )= 0.5 % sulphated ash = 0.1 % , amoxicillin 10 mcg(antibiotic disc) (250 disc) , amoxicillin 2 mcg + clavulanic acid 1 mcg (antibiotic disc) (250 disc) , amoxicillin 25 mcg(antibiotic disc) (250 disc) , amoxicillin clavulanate disc 20 mcg (antibiotic disc) (250 disc) , amoxycillin clavulanate (antibiotic disc) 10mcg (250 disc) , amphetamines 100 ml , amphotericinb powder (solubilized powder, g irradiated ) 50 gm , amphotericin b (mic e test strip) , ampicillin (antibiotic disc)10 mcg (250 disc) , ampicillin 2 mcg (antibiotic disc) (250 disc) , ampicillin 25 mcg (antibiotic disc) (250 disc) , ampicillin sulbactum(antibiotic disc)10mcg(250 disc) , amulgeum pluger , amyl of isoamy alcohal 500ml , amylase 100 ml , amylase kit 2x30ml , ana screening elisa kit 96 tests , anaerobic indicator strip , ? naphthol 500 gm , andrades indicator 100 ml , anhydrous ammonium bicarbonate anhydrous liquid 500 gm , anhydrous anhydrous aluminum chloride 100 ml , anhydrous anhydrous ferric chloride 30% 100ml , anhydrous anhydrous sodium hydroxide( naoh) pellet 250 gm , anhydrous anhydrous sodium hydroxide( naoh) pellet 500 gm , anhydrous anhydrous sodium phosphate monobasic (nah2po4) 500 gm , anhydrous calcium carbonate anhydrous , anhydrous dextrose anhydrous purified 500 gm specification: specific rotation ( [ ? ] 20°/d; c = 10 water ) = +51 to +53° melting range = 145°c 150°c chloride = 0.005 % sulphate = 0.01 % sulphites = passes test arsenic = 0.0001 % iron = 0.0005 % heavy metals ( as pb ) = 0.0005 % loss on drying ( 105°c )= 0.5 % sulphated ash = 0.1 % should be 99.9 % histopathology grade , anhydrous diethylenediamine anhydrous (piperazine ) , anhydrous di sodium hydrogen phosphate anhydrous , anhydrous lithium chloride anhydrous , anhydrous phenol anhydrous , anhydrous potassium phosphate di basic anhydrous 5 kg [ di potassium hydrogen phosphate anhydrous ] assay nlt = 98.0 % ph ( 5 % aqueous solution ) = 8.5 9.6 maximum limits of impurities • chloride = 0.005 % • loss on drying ( 105°c ) = 1.0 % , anhydrous potassium phosphate di basic anhydrous 500 gm ( di potassium hydrogen phosphate anhydrous ) k2hpo4mol. wt. = 174.17 , anhydrous sodium acetate anhydrous 500 gm , anhydrous sodium carbonate anhydrous 500ml minimum assay ( acidimetric ) after drying = 99.5 % maximum limit of impurities moisture = 1.5 % chloride = 0.01 % silicate = 0.02 % sulphate = 0.02 % lead = 0.03 % , anhydrous sodium phosphate dibasic anhydrous assay nlt = 99.0 % ph ( 5 % aqueous solution ) = 8.7 9.4 maximum limits of impurities • loss on drying ( 105°c ) = 0.5 % • heavy metals ( pb ) = 0.001 % • chloride = 0.01 % , anhydrous sodium sulphate anhydrous 500 gm , anhydrous sodium thiosulphate anhydrous , anhydrous tetra sodium pyrophosphate anhydrous , anidulafungin (mic e test strip) , anidulafungin powder (solubilized powder, g irradiated ) , aniline blue solution 500 gm , anti – a 10 ml , anti – b 10 ml , anti – d 10 ml , antisera for escherichia coli o157:h7 2 ml , anti a1 lactin 10 ml , anti ab serum 10 ml , anti d igm 10 ml , anti d rhofinal 10 ml , anti h lactin 5 ml , anti hcv ab elisa 1 x 96 , anti human globin 5 ml , anti sera for salmonella typhi poly h 2 ml , anti sera for salmonella typhi poly o 2 ml , anti sera for shigella species 2 ml , anti sera for vibrio cholerae classical 2 ml , anti sera for vibrio cholerae eltor 2 ml , anti streptosylin 100 ml , antigen v.d.r.l. 250t , antitrypsin 100 ml , apo cal 5 point 100 ml , apo calibrator 100 ml , apo a 100 ml , apo b 100 ml , apt broth 500 gm , aptt reagent 3ml , aptt reagent 5 ml , aq potassium permanganate 0.25% 100 ml , aqua peg 40 hydrogenated castor oil, glycerin, aroma, sodium gluconate, sucralose, octinidine hcl, citric acid, bht , aqua winth apip 500 ml , aqua, cocanidopropylamine oxide peg 7 glyceryl cocoate, glycerin hydroxyethyl cellolose, lactic acid, octenidine hcl, allantion , aqua, glycerine cocamidopropylamine oxide, sodium lactate, allantion, octenidine hcl ethylhexyl glycerine , aqueous citric acid 0.5% 100 ml , aqueous phenol 5% 500 ml , aqueous silver nitrate 5% 100 ml , aqueous sodium metabisulphite 1% 100 ml , aqueous sulphuric acid (h2so4) 3 % 250 ml , arginine decarboxylase broth , asparagine proline broth , asparagine 100gm , ast (sgot) 100 ml , ast (sgot) kit 2x150ml , ast sensitivity disc 5x250 d , astrovirus,stool, antigen, ridascreen, drg international r.biopharma , atropine 500 ml , atropine sulphur 500 ml , au consumables kit 1 kit , auramine o 1000 ml , auramine o 250 ml , auramine o 500 ml , australia antigen (0.3 ng/ml) 100 test , automated rapid mycobacterium culture differentiation and sensitivity system (liquid culture) , available iodine (1.0 % w/v) in water soluble base (contains sodium iodide and surfactants) ( ) , available iodine (1.0% w/v) and watersoluble base (contain sodium iodide and surfactant) manufacturer / marketing company should be certifying according to din en iso , available iodine 1% w/v in an aqueous <5 sodium iodide, <1 surfactant base, <88 water shelf life of 5 years, pack size: 500 ml bottle , azithromycin (antibiotic disc) 15mcg (250 disc) , azlocillin(antibiotic disc)75mcg (250 disc) , azlocillin 30 mcg (antibiotic disc) (250 disc) , aztreonam (antibiotic disc)30mcg (250 disc) , bacitracin 20 mcg (antibiotic disc) (250 disc) , bacitracin disc (antibiotic disc)16mcg 100 disc , bacterial antigen rapid latex agglutination test for meningitis 100 test , bag autoclavable bags 900g (size 12x24, transparent bags ) , bag autoclavable bags, size s (8x12) (should be high grade plastic, for autoclavable, for laboratory use) , bag autoclavable bags, size l (14x19) (should be high grade plastic, for autoclavable, for laboratory use) , bag b bag double – each , bag b bag paediatric each , bag b bag penta – each , bag b bag quadruple – each , bag b bag triple – each , bag biohazard bag medium (discarding pouch (red – black) sizes 12 x 12 for syringe & needle discarding (100 pieces/pack)) , bag biohazard bag small (discarding pouch (red – black) sizes 8 x 12 for gel & tips discarding) , bag biohazard bags large (autoclaveable) , bag biohazard bags medium (autoclaveable) , bag blood bag single – each , bag sample bags 96w , bag top to bottom each , bag top to top each , bag zip lock bags each , band aid round , baramathymol blue 500 ml , barbitone 500 ml , barbiturates 100 ml , barbituric acid, solid (powder) 25 gm , barium carbonate 500gm , barium chloride 500 gm , barrit reagent a 250 ml , barrit reagent b 250 ml , basic fuchsin 0.15% 500 ml , basic fuchsin 0.5% 500 ml , bd facc lysing solution 1pc , bd facs permebilizing solution 1 pc , b d glucan test for aspergillus each kit , beaker 100 ml , beaker 1000 ml , beaker 250 ml , beaker 500ml each , beaker 2000ml each , beef extract powder 250 gm , beef extract powder 500gm , benedict’s reagent 5l qualitative laboratory reagent for detection of sugar in urine. , benedict’s solution 500ml appearance = clear pale blue liquid odourless melting point = 0°c ( 32°f ) water boiling point = 100°c ( 212°f ) water evaporation rate < 1 vapour pressure ( mmhg ) = 14 water vapour density ( air ) =1 = 0.7 water specific gravity = 1 ( water ) solubility complete , benzalkonium chloride solution ip (0.5 % v/v), equivalent to benzalkonium chloride (0.25 % w/v) , benzidine powder 100 gm , benzidine powder 25 gm , benzidine powder 250 gm , benzidine powder 500gm melting range = 127°c 129°c solubility in ethanol to pass test sulphated ash = max. 0.05 % sulphate to pass test. , benzodiazepines 100 ml , benzoic acid 500 ml , beta mercaptoethanol 200 ml , beta 2 macroglobulin 100 ml , betadine 10% 250 ml , betadine 10% 500 ml , betaxolol 25% , betaxolol 85% , bicarbonatecalibrator 100 ml , bile esculin azide agar 500 gm , bile esculin disc pack of 100 disc , bile esculin powder 250 gm , bile esculin powder 500 gm , bilirubin kit 2x250ml , billirubin d 100 ml , billirubin total 100 ml , biotin 4 amidobenzoic acid sodium salt50mg (purity (tlc) > 95 %, mol wt. 385.4) , bismarck brown 1 kg 100gm glan bottle dye content 50 % solubility = h20 : 10mg/ml clear to turbid red orange to red form = powder grade = certified by biological stain commission quality level = 100 , bismarck brown 25 gm , bismuth sulphite agar , blade blade for cryostat (frozen) , blade cryostat blade for leica – 50 pcs( proprietary item)low profile made of stainless steel with high durability. disposable blades819 80 mm long x 8 mm high x 0.25 mm thick blades , blade microtome blades – 50 pcs ( proprietary item)high profile disposable blades818 stainless steel , bleach hydrogen peroxide of minimum 30% and oxygen based bleaching agent 5 ltr. , bleach sodium hydroxide maximum 5% based bleaching agent 5 ltr. , blood agar base – 250 gm , blood agar base 500 gm , blood free campylobactor agar , blood urea nitrogen 2x150ml , bolton broth (base) , bolton selective supplement , bone marrow aspiration needle – metal,reusable , salah type with component includingtrocar , cannula & adjustable side guard size –no 14 , no – 16 & no – 18 g , 5 cm longneedle , bone marrow biopsy needle ergonomic handle. material : stainless steel remover guide provided with indicators to facilitate the sample expulsion and that allows samples lenght check. provided with a special lock for a safe removal of the sample , boric acid 500 gm , bottle blood culture bottle (conventional) adult each , bottle blood culture bottle 100ml , bottle blood culture bottle 125ml , bottle blood culture bottle 30 ml , bottle blood culture bottle(conventional) pediatrics each , bottle brown bottle reagent 1000 ml , bottle brown bottle reagent 250 ml , bottle brown glass bottles 100 ml , bottle clear glass bottles, volume 1000ml (clear glass bottle with screw cap for laboratory use ) , bottle clear glass bottles, volume 250ml, (clear glass bottle with screw cap for laboratory use ) , bottle clear glass bottles, volume 500ml (clear glass bottle with screw cap for laboratory use ) , bottle clear glass bottles, volume 2000ml (clear glass bottle with screw cap for laboratory use ) , bottle drop bottle each , bottle mc cartney bottle 30ml each , bottle myco f bottle each , bottle reagent bottle – 100 ml (silicate with droper cap – 100 pc) , bottle reagent bottle 1lit , bottle reagent bottle 500ml , bottle reagent bottle 100ml , bottle reagent bottle 250ml , bottle spray bottles each , bottle sprey gun with bottle (500 ml) nos. , bottle sqeeze bottle each , bottle universal bottle 30 ml with screw cork , bottle universal bottle glass withrubber washer and cap 500 pcs , bottle wash bottle 500ml , bottle wash bottle 250ml , bovin serum albumine 10mg (agarose electrophoresis > 96 %cell culture test pass) , bovine albumin 22% 10 ml , box autoclave biological indicator box (geo.atropheus ) 50 x 1 ml , box bowie – dick compact box , box cap box each , box cryo box(1 ml)(each pack 500 vials) , box cryo box 1.8ml box of 04pcs , box cryo boxes (5ml) each , box eto indicator box , box gluffs boxeach , box micro pore box each , box plasma casset box , box slide box , box softner water kit box each , box steam emulating indicator box , box sterilization indicator box , box tip box 0.2 10?l ( 10pcs ) , box tip box 200 1000?l (10pcs ) , box tip box 2 200?l ( 10pcs ) , brain heart infusion agar 250 gm , brain heart infusion agar 500 gm , brain heart infusion broth 250 gm , brain heart infusion broth 500 gm , brain heart infusion broth powder 250gm , brain heart infusion broth powder 500gm , bramathymol blue 125ml , bramathymol blue 500 ml , brilliant cresyl blue solution 100gm , brilliant cresyl blue solution 25gm dark green colour powder absorption maxima = 623 628 specific absorptivity of 1%/1cm ( ?max = 0.005 gm/l ) melting point = 233 236°c , brilliant green bile broth 2% , bromine sample 250 gm , bromo phenol blue 500 ml , bromo phenol blue powder 10 gm , bromothymol blue 125gm , brush cyto brush – material plastic color white packaging type box to minimize trauma , brush test tube brush each , brush washing brush 12” , brush washing brush 6” , buffer saline sodium citrate buffer 500 ml , buffer for seroprotin electrophoresis each , buffer solution hemoglobin 1000 ml , buffered formal acetone 500 ml , buffered peptone water , butane gas , c reactive protein kit (rapid test kit) 100 test , c3control level 1 100 ml (compactible with dirui cst240) , c3with calibrator 100 ml (compactible with dirui cst240) , c3 100 ml , c4control level 2 100 ml (compactible with dirui cst240) , c4 100 ml , c4 with calibrator 100 ml (compactible with dirui cst240) , ca125 1 ml , calamine powder 250 gm , calcium arsennazo111 100 ml , calcium chloride powder 500 ml , calcium choride solution for aptt 10ml , calcium kit 2x150ml , calcium oxide 250 ml , calcium phosphate dibasic dihydrate , calcium sulphate 500 ml , calcium sulphate dihydrate , calcoflour white 100 ml , calcoflour white 25 ml , calcoflour white 50 ml , calibrator ldl ( us ) 100 ml , calponin 1 ml , calretinin 1 ml , candida albicans , candle jar 5 ltr. , carbamezapine 100 ml , carbenicillin 100 mcg (250) , carbo red 500 ml , carbohydrate consumption broth base , carbolfuschin 250 ml , carbol fuschin 500 ml , carbol fuschin 125ml , carbolic acid 500 ml , cardiac controls 5 ml , carmine powder 250 gm , casein 500 ml , caspofungin (mic e test strip) , caspofungin powder (solubilized powder, g irradiated ) , ccda selective supplement , cd 10 10 ml , cd 10 apc 1 pc , cd 10 pe 1 pc , cd 100p , cd 117 1 ml , cd 117 apc 1 pc , cd 13 cy 7 1 pc , cd 15 10 ml , cd 19 1 ml , cd 19 pe cy 7 1 pc , cd 20 1 ml , cd 20 fitc 1 pc , cd 3 1ml , cd 3 cy 5.5 1 pc , cd 3 per cp cy5.5 1 pcs , cd 30 1 ml , cd 31 1 ml , cd 33 pe 1 pc , cd 34 apc 1 pc , cd 34 endothelial cell marker 1 ml , cd 38 c 5.5 , cd 4 pe cy 7 1 pc , cd 45 1 ml , cd 45 apc h7 1 pc , cd 5 1 ml , cd 5 pe 1 pc , cd 56 1 ml , cd 64 fitc 1 pc , cd 7 apc 1 pc , cd 79 a pe 1 pc , cd 8 fit c 1 pc , cd 99 1 ml , cd k4 1 ml , cdna synthesis kit (50 reactions) , cea 1 ml , cedar wood oil –100ml , cedar wood oil 25 ml , cefaclor (antibiotic disc)30mcg(250 disc) , cefadroxyl 30 mcg (antibiotic disc) (250 disc) , cefamandole (antibiotic disc) 30mcg(250 disc) , cefazoline (antibiotic disc)30mcg (250 disc) , cefdiniar 5mcg (antibiotic disc) (250 disc) , cefepime (antibiotic disc) 30 mcg (250 disc) , cefixime 5 mcg (antibiotic disc) (250 disc) , cefmatazole (antibiotic disc) 30mcg (250 disc) , cefoaximen + sulbactam (antibiotic disc) 10 mcg (250 disc) , cefoaximen + sulbactam (antibiotic disc) 30 mcg (250 disc) , cefonicid (antibiotic disc)30 mcg (250 disc) , cefoperazone (antibiotic disc)75 mcg (250 disc) , cefoperazone 30 mcg (antibiotic disc) (250 disc) , cefoperazone salbactum 10mcg (antibiotic disc) (250 disc) , cefotaxime (antibiotic disc)30 mcg (250 disc) , cefotaxime 5 mcg (antibiotic disc) (250 disc) , cefotaxime clavulanic acid (antibiotic disc) 10mcg (250 disc) , cefotaxime clavulanic acid (antibiotic disc) 30 mcg (250 disc) , cefotetam (antibiotic disc)30mcg (250 disc) , cefoxitin(antibiotic disc)30mcg (250 disc) , cefoxitin 10 mcg (antibiotic disc) (250 disc) , cefperazone 75 mcg +sulbactum 30 mcg (antibiotic disc) (250 disc) , cefpodoxime(antibiotic disc)10mcg (250 disc) , cefprozil 30 mcg (antibiotic disc) (250 disc) , cefsulodin 30 mcg (antibiotic disc) (250 disc) , ceftaroline(antibiotic disc)30mcg (250 disc) , ceftazidime 10 mcg (antibiotic disc) (250 disc) , ceftazidime clavulanic acid(antibiotic disc)30mcg (250 disc) , ceftazidime clavulanic acid 10mcg (250 disc) , ceftazidime(antibiotic disc)30mcg(250 disc) , ceftazidime avibactum (antibiotic disc)20 mcg (250 disc) , ceftazidime avibactum (antibiotic disc)30 mcg (250 disc) , ceftiofur 30 mcg (antibiotic disc) (250 disc) , ceftizoxime(antibiotic disc)30mcg (250 disc) , ceftriaxone (antibiotic disc) 30mcg ( 250 dics) , ceftriaxone + sulbactam (antibiotic disc) 10 mcg ( 250 dics) , ceftriaxone + sulbactam (antibiotic disc) 30 mcg ( 250 dics) , ceftriaxone 30mcg+ sulbactam 15mcg+ edta 100mcg(antibiotic disc) ( 250 dics) , cefuroxime (antibiotic disc)30 mcg ( 250 dics) , cefuroxime 5 mcg (antibiotic disc) (250 disc) , cell clean 50 ml , cell pack 20 ltrs , cellulose acetate strip 25 x 130 , cellulose acetate strip 57 x 130 , cellulose powder , cephalexin 30 mcg (250 disc) , cephalothin(antibiotic disc) 30mcg ( 250 dics) , cephradine 30 mcg (antibiotic disc) (250 disc) , cepodoxime (antibiotic disc) p. size 5 x 250 , c erb2 onco proton her2neu 3 ml , cerbenicillin (antibiotic disc) p. size 5x 250 , ceruloplasmin 100 ml , cetrimide agar , chamber dark humidity chamber , chamber multipurpose staining chamber body yype – plastic size – 46x25x4 cm slide capacity – 24 , chamber neubuers chamber with silver lining each , chaps (cholamidopropyl)dimethylammonio] 1 propanesulphonate}) , charcol , chart marker pen each , chemical indicators class6 steam strips , chemistry controls (more than 30 parameters) 5 ml , chikungunya igm elisa kit ( 1 x 96) , chikungunya igm, igg rapid kit single , chloramphenicol (antibiotic disc)30 mcg (250 disc) , chloramphenicol 10 mcg (antibiotic disc) (250 disc) , chloramphenicol yeast extract glucose agar , chlorhexidine gluconate and cetrimide antiseptic 500 ml (equivalent tosavlon) , chlorhexidine gluconate and cetrimide antiseptic lotion pack 1l (like savlon) , chlorhexidine gluconate solution ip 10% v/v equivalent to chlorhexidine gluconate2% w/v ethanol ip 70% v/v 500 ml , chlorhexidine gluconate solution ip 20 % v/v, (equivalent to chlorhexidine gluconate 4 % w/v) , with isopropanol<10%, ethoxylated alkylphenol<10%, fatty acid diethanolamide<10%, acetic acid glacial<1%, cellulose and fragrance<10% emollient & moisturising agents passes en 1499 standards, pack size: 500 ml bottle , chloroform 1000ml (molecular bio use only, molecular weight 119.38) , chloroform 200 ml , chloroform 2.5 ltrs , chlorophenol red 500 ml , chloroxylenol 4.8 % w/v(equivalent todettol) 1 ltr , chocolate agar plate , cholesterol hi co 100 ml , cholesterol kit 2x250ml , cholinesterase 24 ml , chopping board – each( grossing boards ) features measurement guides printed onto board made of heavy duty, stain resistant, thick polyethylene will not dull fine surgical blades features a drain groove, carved into the edge to contain fluids durable design will make the board last for years, without changing shape, bending, or swelling , christensen’s urea , chrom agar 500 gm , chromium (iii) chloride hexahydrate , chromium oxide 5% 100ml , chromogenic agar listeria (listeria ottaviani agosti agar base) , chromogenic carbapenem resistant gram negative bacterial screening agar , chromogenic colistin resistant gram negative bacterial screening agar , chromogenic esbl producing gram negative bacterial screening agar , chromogranin a 1 ml , cinoxacin(antibiotic disc)100 mcg (250 disc) , ciprofloxacin (antibiotic disc)5 mcg (250 disc) , ciprofloxacin 1 mcg (antibiotic disc) (250 disc) , circular chart recorder each , citric acid (c6h8o7) 500 ml , ck –mb kit 75 ml , ck mb with calibrator 100 ml (compactible with dirui cst240) , ck 20 1 ml , ck 5 / ck 6 1 ml , ck 7 1ml , ck mb calibrator 100 ml , ck nac 100 ml (compactible with dirui cst240) , clarithromycin (antibiotic disc) 15 mcg (250 disc) , clarithromycin 2 mcg (antibiotic disc) (250 disc) , cleaning & disinfecting sol ( like lysol) 5 ltrs , cleaning solution 1 kit , cled cystine lactose electrolyte deficient (cled) agar 500 gm , clindamaycin (antibiotic disc)2 mcg (250 disc) , cloxacillin 1 mcg (antibiotic disc) (250 disc) , cmpo fitc 1 pc , cmv igg elisa 1 x 96 (1 pack) , cmv igm elisa 1 x 96 (1 pack) , coagulas plasma , cocaine 100 ml , colchicine powder , colcimed 5 mg , coliform agar , colistin 10 mcg (250 disc) , colistin 25 mcg (250 disc) , colistin disc(antibiotic disc )( 1x100) each , colistin sulphate salt powder1 gm , combistrix 100 t , complete haemacytometer set (neubeur blood counting chamber brightlined) number of memory sticks ?1 item weight ?100 g package dimensions ?5 x 3 x 1 cm; 100 grams country of origin ?germany , congo red 100 ml , container autoclavable biohazards waste container large , container autoclavable biohazards waste container medium , container microtube container 1000ml(it should be madeup of medical grade polypropylene or polycarbonate, confirming to us fda code of federal regulations title 21, and should be autoclavable) , container microtube container 500ml (it should be madeup of medical grade polypropylene or polycarbonate, confirming to us fda code of federal regulations title 21, and should be autoclavable) , contains subtilisin tridecylpolyethylenglycolether propan 2 ol, glycerol passes en 13624, en 13727, en 14561 and en 14562 standards, pack size: 2 litre bottle , cooked meat broth , coomassie brilliant blue g250 , coomassie brilliant blue r250 , coplin jar –made of polypropylene microwave safe can hold 10 slides (slide size: 25 x 75 x 1.0mm) & 50 slides interior is grooved to hold slides vertically domed and shallow thread screw cap , coplin jar plastic , copper acetate 500 gm , copper sulphate crystal 500 gm , corn meal agar 500 gm , cotrimoxazole(antibiotic disc)1.25 mcg (250 disc) , cotrimoxazole(antibiotic disc)23.75mcg (250 disc) , cotton tip applicator , covid 19 igg , cpk kit 2x75ml , creatinine 100 ml , creatinine enzymatic 100 ml (compactible with dirui cst240) , creatinine kinase (ck – nac) 100 ml , creatinine kinase (ck) kit 2x75ml , creatinine kit 2x500ml , creatinine powder 25 gm , creatinine zinc chloride 500 gm , cresyl blue powder 250 gm , cronobacter isolation agar , cronobacter sakazakii , cronobactor selective broth , crplatex high sensitative calibrator 100 ml , crplatex normal calibrator 100 ml , crp 100 ml , crp quantitative 100 ml (compactible with dirui cst240) , crp quantitative (range 0 100) 100 ml (compactible with dirui cst240) , crp reagent (rapid test kit) 100 test , crp latex , cryo globes large – 100 pc , cryo globes medium – 100 pc , cryo globes small – 100 pc , cryo tags each , cryptococcal latex agglutination test 50 tests , crystal blue powder 500 gm , crystal sulphate 125ml , crystal sulphate 500 ml , crystal violet , crystallin phenol powder 250 gm , crystalline phenol powder 500 gm , ctla 4 (monoclonal ab) 100ug , ctla 4 (polyclonal ab) 200ul (0.5 1.5 ug/ul) , cuprous chloride (cu ii chloride) , cylinder glass measuring cylinder 250 ml , cylinder glass measuring cylinders 100ml , cylinder glass measuring cylinders 1000ml , cylinder glass measuring cylinders 2000 ml , cylinder glass measuring cylinders 25ml (it should be madeup of polymethylpentene, confirming to us fda code of federal regulations title 21, and should be autoclavable) , cylinder glass measuring cylinders 500ml , cylinder glass measuring cylinders 50ml , cystatin 1 ml , cyto fix 125 ml , cytomegalovirus, serum, igm, biorad, drg international , dapi 10 mg , dapi dihydrochloride (4,6 diamidino 2 phenylindole dihydrochloride) , d biotin , dca media 250 gm , dca media 500 gm , d dimer 100 ml , d dimer control level 1 100 ml (compactible with dirui cst240) , d dimer control level 2 100 ml (compactible with dirui cst240) , d dimer with calibrator 100 ml (compactible with dirui cst240) , decarboxylase base 500 gm , decotrorising reagent destainer (german) electrophoresis each , dengue igg elisa , dengue igm elisa 1 x 96 , dengue ns1 elisa 1 x 96 , dengue nsi igm, igg, rapid kit 50 tests , dental cement 1 kg , deoxycholate citrate agar , deproteinising solution 1000ml , desmin 1 ml , destainer & clearing solution 500 ml , d gluconic acid , di sodium hydrogen phosphate dihydrate purified 500 gm , di sodium hydrogen phosphate dihydrate purified 250 gm , diaectyl monoxime 25 gm , diamond pencil marker 50 in no.(used for marking slide or test tube etc.diamond pencil for writing information onto histological and cytological slides.suitable for most laboratory glass surface, metal and ceramic. thin diamond tip for a perfect writing.) , diastic 100 t , dichloro phenol 2 6 – 10 gm , dichloro phenol indo phenols 2 6 – 10 gm , diethyl ether (hplc grade) 500 ml , differential reinforced clostridial broth (drcm) , digitoxin ( tdm calibrator ) 100 ml , digoxin 100 ml , dimethyl sulfoxide (dmso) , di potassium hydrogen ortho phosphate (k2hpo4) 500 gm , dipotassium hydrogen phosphate 500 gm , disinfectant 100 g of granules contain the following active ingredients: 43 g sodium per carbonate, 22 g tetraacetylethylenediamine. passes en 13624, en 13727, en 14348, en 14561, en 14562, en 14563, en 13704 and en 14476 standards, pack size: 1.5 kg box , disinfectant chlorhexidine gluconate solution ip 20 % v/v, equivalent to chlorhexidine gluconate 4.0 % w/v 1) en 13624 yeasticidal 2) en 13727 bactericidal500 ml , disinfectant ortho – phthalaldehyde 0.55% w/wwith test strip & deactivator quantitative suspension test for the evaluation of mycobactericidal activity of chemical disinfectants in the medical area including instrument disinfectants test method and requirements (phase 2/step1) , disinfectant ortho phthalaldehyde – 0.55% non corrosive, high level instrument disinfectant surfactant free, pack size: 5 litre jar , disinfectant polymeric biguanide hydrochloride (in house) (< 10 %) alkyl dimethyl benzyl ammonium chloride & didecyl dimethyl ammonium chloride) (in house) (< 10 %) quantitative non porous surface test for the evaluation of bactericidal and/or fungicidal activity of chemical disinfectants , disinfectant sodium parborate monohydrate in house 50% w/w quantitative suspension test for the evolution of sporicidal activity of chemical disinfectant of used in food industrial domestic & institutional , disinfectant sodium perborate monohydrate (in house) (50 % w/w) quantitative suspension test for the evaluation of sporicidal activity of chemical disinfectants used in food, industrial, domestic and institutional areas , disinfectant 500 ml , disinfectant powder disinfectant powder for surface cleaning containing potassium monopersulphate 40 50 % sodium c10 – 13. alkybenzen sulphonate 10 20 % sodium ( like virkon) 5 kg , disinfectant solution 4.25% ahp based surface disinfectant concentrate. ltr. , disinfectant solution 5th generation qac based disinfectant having didecyl dimethyl ammonium chloride and n alkyl dimethyl benzyl ammonium chloride ltr. , disinfectant solution aldehyde surface & environmental disinfectant – 5 ltr. , disinfectant solution aldehyde surface & environmental disinfectant – 500 ml , disinfectant solution disinfectant containing electrolysed water with neutral ph, hypochlorous acid, sodium hypochlorite – 5 ltr. , di sodium hydrogen orthophosphate dodecahydrate , di sodium hydrogen phosphate 500 gm , di sodium metasilicate upto 30%, nonionic surfactant and anionic surfactant based powder with optical brightner kg. , di sodium tetraborate decahydrate (borax) , disposable fluid collection system each , distilled water/ di water / deionised water 5 l appearance density = 999.972 melting point = 0°c ( 32°f ) thermal conductivity = 0.58 w/mk 1 refractive index = 1.3325 viscosity = icp specific heat capacity = 75.375 ± 0.05 j/mk 1 , dixon agar 250/ 500 gm , dmso (dimethyl sulfoxide)100/250/500 ml , dna extraction kit 250 r , dna extraction kit 50 test , dna isolation kit from 200 ul blood sample 100 tests , dna ladder (100 bp) 100 ul (0.5 ug/ul) , dna ladder (50 bp) each vial , dna loading dye 20 ml , dna zap pcr dna degradation solutions 5 x 1ml , dnase inhibitor (50 reactions) , dnph (2 4, dinitrohphenylhydrazine) 500gm laboratort reagent grade, >97.0% , dntps (10 mm) each 10 ml , documentation hand labeler gun nos. , doripenam(antibiotic disc)10 mcg (250 disc) , doxycycline (antibiotic disc) 30 mcg (250 disc) , dpx mountant 500 ml , dropper each , dulcitol discs each , dulcitol powder 25gm , dutp 2 gm , e.s.r fluid 500ml , each 100 g contains didecyldimethyl ammonium chloride: 7.0 g corrosion inhibitors, fragrance, excipients q.s. (alcohol free, aldehyde free), pack size: 500 ml bottle , each 100 g contains ethanol ip: 10.0 g, 2 propanol ip: 9.0 g/ isopropanol 1 propanol: 6.0 g/ n propanol provided with convenient hand sprayer, pack size: 250ml bottle , each 100 gm contain dodecylbiyspropylene triamine 9.2 gm and didecyldimethyl ammoinum chloride 13 gm , each 100 gm containes 1.6 dihydroxy 2.5 dioxyhexane (chemically bound formadehyde) in house 11.2gm, glutadehyde 5gm, benzalkonium chloride 5gm, alkyle urea derivative in house 3 gm test report from reputed indian or international lab , each 100 gm contanes true propanol 40 gms 1 propenol 22 gm saniocid , each 100 gms contains : sodium salicylate ip0.46 g sodium benzoate ip 0.59 g water soluble baseq.s , each 100 gms contains 2 propanol (63 gm) benzalkonium chloride (0.025 gm) , each 100 gms contains: 2 propanol40 gm1 propanol22gm saniocid250ml , each 100 gms contains: 1,6 dihydroxy,2 5 dioxyhexane (chemically bound formaldehyde), (in house) (11.2 gm) glutaraldehyde (5.0 gm), benzalkonium chloride (5.0 gm), alkyl urea derivative (in house) (3.0 gm), test report from reputed indian or international labs against viruses as per dvv guideline , ec broth , e cadherin 1 ml , e check 123 1pc , ecoshield solution – 1 ltr. , edta, disodium salt 2 hydrate , egfr 1 ml , ehrlich’s aldehyde reagent 100 ml , ehrlich’s aldehyde reagent 125 ml , ehrlichs aldehyde test 250 ml , ehtnol ip 10gm, truepropenol 9gm, 1 propenol 6 gm , electric ph metre , electrical digital timer , electronic cell counter with 10 keysfor dlc digital blood cell counter bcc 10 is a feature loaded cell counter with perfect quality no. of cells: 10 no. of keys: 12 body material: abs power source: 2 x 1.5v (aa) , electronic cell counter with 9 keys for dlc , electrophoresis hemoglobin & protein buffer 500 ml , elelay (gel) 1 kg , elisa kit neurocysticercosis igm/igg 1 x 96 , ellners broth , ema 1 ml , enoxacin 10 mcg (250 disc) , enrofloxacin 5 mcg (250 disc) , enterobacter aerogenes / klebsiella aerogenes , enterococcus faecalis , eorin 0.1%– 500 ml , eosin & nigrosin stain: ( twin pack)specification: a.. 0.5% eosin y , 290 mosm/kg nacl 1x 30mlb. 10% nigrosin , 290 mosm/kg nacl 1x 30ml , eosin yellowish indicator for microscopy 25 gm specification: assay ( on dried substance ) = 90% ph (1%, water ) = 6.5 7.5 adsorb on maxima (in water) = 515 518 nm absorption ratio ( max 15nm/max+15nm ) 1.21 1.77 specific extinction ( e1% 1cm; ? = 516nm, water ) [ on dried substance ] = 1230 1280 tlc analysis passes test loss on drying ( 105°c ) = 8% suitability for microscopy passes test , epson (ribbon cartridge) nos. , epstein barr virus igm (ab) 1 x 96 , equivalent to cetrimide ip (15 % w/v) chlorhexidine gluconate solution ip (7.5 % v/v) equivalent to chlorhexidine gluconate (1.5 % w/v , erg 1 ml , ertapenem (antibiotic disc)10mcg (250 disc) , erythromycin (antibiotic disc)15 mcg (250 disc) , erythromycin 10 mcg (antibiotic disc) (250 disc) , erythromycin 2 mcg (antibiotic disc) (250 disc) , erythromycin 5 mcg (antibiotic disc) (250 disc) , estrogen receptor 3 ml , etbr– 100 r each , ethambutol/myambutol 25 mcg (antibiotic disc) (250 disc) , ethambutol/myambutol 50 mcg (antibiotic disc) (250 disc) , ethanol 100% (molecular grade) 500 ml , ethanol 1000 ml , ethanol 250 ml , ethanol 500 ml , ethanol ip (10 gm) 2 propanol (9 gm), 1 propanol (6 gm) , ethanol ip (3.0 % v/v) benzalkonium chloride solution ip (0.5 % v/v), equivalent to benzalkonium chloride (0.25 % w/v) , ethidium bromide solution 10ml (hplc purified, suitable for use in gel electrophoresis) , ethionamide/trecator 25 mcg (250 disc) , ethnol ip 10 gm to propanol 9gm 1 propanol 6 gm, bottle manufacturer / marketing company should be certifuing accourding to din en iso 9001, 14100 & 13485 certificate , ethyl acetate 250 ml , ethyl alcohol 500ml (high grade, for use in molecular biology experiments, purity =99.99%, should contain isoamyl alcohol =0.05, 2 propanol =0.01, and higher alcohols =0.01. ) , ethyl violet azide broth (eva broth) , ethylacetate(1 litre) (laboratort reagent grade, =99.0%) , ethylenediaminetetraacetic acid powder (500gm) (acs grade, for molecular biology use) , ethyl hexadecyl dimethyl ammonium ethylsulphate 0.2 gms (mecetronium ethylsulphate) each 100 gms contains 2 propanol 45 gms, 1 propanol 30 gms, with third party test report from reliable lab, or indian or european norm certificates , eto cartridge nos. , external quality contro immunology controls (immno tubidimetric methods > 5 parameters) , external quality control clinical chemistry (more than 30 parameters) , external quality control hba1c and a2f , external quality control immunoassay (more than 20 parameters) , fail safe pcr pre master mix kit 60 units (should capable of amplify high gccontent or secondary structure template, must contain all 12 premixes,) , faropenem (antibiotic disc) 5mcg (250 disc) , fast blue bb salt – 500 gm , fast gernet bgbc salt 500 gm , febrile antigen set (widal tube test) 10 pieces , ferric alum 2% 500 ml , ferric alum 99% 250 gm , ferric chloride 25 gm , ferric chloride 5% 100 ml , ferric nitrate , ferritin 100 ml , ferrous ammonium sulfate , ferrous chloride , fetal bovine serum gold 500 ml , ficoll , fixative solution , flask conical flask 1000ml , flask conical flask 125ml , flask conical flask 250 ml , flask conical flask 500ml , flask round bottom flask 250ml , flask round bottom flask 1000ml , flask round bottom flask 125ml , flask t 25 flask , fli 1– 1 ml , floater (3 4) , flouride powder 500 gm , fluconazole (mic e test strip) , fluconazole powder (solubilized powder, g irradiated ) 50 gm , flucytosine (mic e strip) , flucytosine powder (solubilized powder, g irradiated ) 50 gm , fogging kit – each , forcep blunted dissecting , forcep pointed , forcep ptfe pointed , formaldehyde solution 1 ltr , formaldehyde solution 250 ml , formaldehyde solution 5 ltrs hcho [ mol. wt. = 30.08 ] solubility = miscible with water and absolute alcohol forming colourless solutions. weight per ml at 20°c=1.085 1.095g assay = 37.0 41.0 w/v hcho maximum limits of impurities acidity 3 ml ash = 0.02% chloride (cl) = 0.001 % , formaldehyde solution 500 ml , formaline tab 100 pcs , formic acid 500 gm , fosfomycin (antibiotic disc) 200 mcg (250 disc) , fosfomycin 50 mcg (antibiotic disc) (250 disc) , fosfomycin with glucose 50 mcg (antibiotic disc) (250 disc) , fouchet’s reagent 250 ml for bile pigment bilirubin for lab use only , fouchet’s reagent 500 ml , fraser broth , fraser listeria selective supplement , fructose powder 500 gm , fuchsine acid 500 ml , furaxone 100 mcg (250 disc) , furazolidone 100 mcg (250 disc) , fusidic acid 10 mcg (250 disc) , g.v. lotion 100ml , g.v. powder 500 gm , g 6 pdh 100 ml (compactible with dirui cst240) , galactomannan lateral flow assay – 50 t , galactose 1 phosphate (40 units) (purity (hplc) > 98 %) , gatifloxacin (antibiotic disc) p. size 5x 250 (250 disc) , gcdep 1 ml , gds e coli , gel red 1 x 0.5 ml , gel scoup each , gelatin agar , gelatine powder 500 gm , gentamicinhs (antibiotic disc)120 mcg (250 disc) , gentamicin (antibiotic disc) 10 mcg (250 disc) , gentamicin 30 mcg (antibiotic disc) (250 disc) , geobacillus stearothermophilus ampoules , geobacillus stearothermophilus spores (biological indicator) 50 x 1 ml , gfap 1 ml , ggtp 10x2ml , giemsa powder 25 gm appearance = dark green to black crystal or powder melting point = 300°c ( lit ) solubility = 10mg soluble in 10ml of methanol to give clear blue solution with greenish fluorescence. loss on drying at 110°c nmt = 8.0 % , giemsa powder 250 gm , giemsa powder 500 gm , giemsa stain 250 ml , giemsa stain 500 ml , glacial acetic acid 2.5 l boiling point = 116 118°c assay ( acidimetric ) = 99.7 colour = 10 hazy titratable base = 0.0004 meq/gm acetic anhydride = 100 ppm chloride = 1 ppm heavy metal ( as pb ) = 0.5 ppm sulphate = 1 ppm iron = 0.2 ppm evaporation residue = 10 ppm , glacial acetic acid 500 ml , glacial acid/glocalic acid 500ml , glasspetridish (90 mm) , glasspetridish(100 mm) , glasspetridish(120 mm) , glasspetridish(90 mm ) , glass beads (small size) 1000 gm , glass beads (small size) 250 gm , glass beads (small size) 500 gm , glass cover silips 22 x 22 mm 10 gm , glass cover silips 22 x 24 mm 10 gm , glass cover silips 22 x 60 mm 10 gm , glass cover slip square shape (18 mm x 18 mm) 10 gm , glass cover slip square shape (22 mm x 40 mm) 10 gm , glass innomer cement grade , glass marking pencil each , glass wool , glove cryo gloves 1 pair , glove nitrile gloves (large) (disposable nitrile gloves, for use in chemical labs, thickness should be =5mil ) , glove nitrile gloves (medium) (disposable nitrile gloves, for use in chemical labs, thickness should be =5mil ) , glove nitrile gloves (small) (disposable nitrile gloves, for use in chemical labs, thickness should be =5mil ) , gloves autoclave/ microwave gloves , glucofuranose , glucose ( hexokinase) 100 ml (compactible with dirui cst240) , glucose hk 100 ml , glucose kit 1 kit 1000 ml , glucose powder 500 gm , glucose salt teepol broth , glutaraldehyde (2.45 % w/v) with test strip & activator , glutaraldehyde 2.45 % w/v purified water 3 7% butylated hydroxyanisole, pack size: 5 litre jar , gluteraldehyde solution 5 ltrs , glycerine 2.5 ltrs , glycerine 400ml , glycerine 500 ml98% w/w min. aqua and rose flavour , glycerol 500 ml , glycine powder(ar) 250 gm (acs reagent, =98.5%, analytical grade) , glycocylated hemoglobin kit 25 t , glycogen kit , glycolic acid 500 ml , glycosylated kit 100 ml , gold chloride 0.1% 100 ml , gold chloride 0.2% 100 ml , gram stain kit 250 ml , gram stain kit 500 ml , grams iodine(crystal) 100 gm , griess assay reagent 500 ml , guanidine hydrochloride , guanidinium thiocyanate , h.c.v. kit rapid 50t , h.i.v. rapid kit50 t , h2o2 250 ml , h2so4 (sulphuric acid) conc 500ml , haematoxylin powder 1 kg , haematoxylin powder 25gm appearance = yellow to brown to tan colour form = powder dye content = 80% solubility in alcohol passes test water 8 % max. spectroscopy peak at 253, ratio 0.98 @ 508/538nm density @ peak 0.519qu , haematoxylin powder stain 125 ml , haemocystin 100 ml , haemocyto meter (german) pcs , haemoglobin estimation , hand rub alcoholwith moisturizer 500 ml 2.5 % v/v chlorhexidine gluconate solution i.p equivalent to 0.5% w/v chlorhexidine gluconate 70 % v/v ethyl alcohol, skin emollients, perfume, fast green as fcf colour. , hand wash solution scrub 500 ml , handrub ethanol 70% v/v handcrub 250 ml , haptoglobin 100 ml , hardness testing kit (for water analysis) each , harris haematoxylin solution ( papanicolaou solution ) 25 gm density = 1.04 gm/cm3 ( 20°c ) ph = 2.3 2.8 ( 20°c ) ci75290 5.3 gm/l al2(so4)3 18h2067gm/l , hav + hev igm elisa 96w , hav igm elisa – 1 x 96 test , hba1c 100 ml , hba1c calibrator 100 ml , hbdh 100ml , hbsag elisa 1 x 96 test , hcv dna extraction kit , hdl cholesterolcalibrator 100 ml , hdl cholestrol direct 100 ml , hdl cholestrol kit 10ml , hdl control 50 ml , hdl cholesterol 100 ml , heamatoxlene powder 250 gm , heamoglobin denatarant 1000 ml , heat block , hektoen enteric agar , hematology external quality control , hematology controls(compatible within sysmex xn 1000) 3 ml , hematoxylin monohydrate 82% , hematoxyllin powder 5 gm , hemo dialysis solution 10 ltrs , hemoglobin electrophoresis kit 100 tests , hemoglobin set – each , hemoglobino meter(0 30 g/dl)(german) pcs , hemoglobinometer calorimetry set , hepatitis a, serum, igm, wantai, dia pro, srl, italy, hepavase (gbc taiwan) , hepatitis b, serum, hbsag, j mitra, biorad , hepatitis c rpd kit (detects core, ns3, ns4 ns5 all hcv genotypes ) – 50 t , hepatitis c, serum, total antibody, j mitra, ortho hcv 3.0, biorad , hepatitis d virus, serum, total antibody, dia pro, srl, italy, gbc taiwan (for research use only) , hepatitis delta each , hepatitis e, serum, igm, wantai, mp diagnostics,dia pro , hepes sodium salt , hev igm elisa 1 x 96 test , hexane 500 ml , hini elisa 96w , hippurate broth , hla dr cy5.5 1 pc , hla b27 pcr kit 96 tests , hma 45 1ml , hmb 45 1 ml , holdar vacutainer holder – each , holder test tube holder each , homocysteine with standard 100 ml (compactible with dirui cst240) , hsv i + iiigg (ab) elisa 1 x 96 , hsv i + ii igm (ab) elisa 1 x 96 , hsv i igg (ab)elisa 1 x 96 , hsv i igm (ab) elisa 1 x 96 , hsv ii igg (ab) elisa 1 x 96 , hsv ii igm (ab) elisa 1 x 96 , hugh leifson medium , hydrated disodium hydrogen phosphate 250 gm , hydrochloric acid ( 35 % ) 500 ml , hydrochloric acid 500 ml , hydrochloric acid 500ml , hydrochloric acid hcl conc 500ml , hydrochloric acid n/10 500 ml , hydrogen peroxide 500 ml , hydrogen peroxide of minimum 30% and oxygen based bleaching agent 5 ltr. , hydrogen peroxide solution 2.5 ltrs contains 6.5% w/v hydrogen peroxide ( non medicinal ) , hydrogen peroxide solution 500 ml , hydrophobic barrier marker pen – reagent blocker (pap pen) use in immunohistochemical applications , hydroquinone 250 gm , hydroquinone buffer 500 ml , hydroxylamine hydrochloride (500gm) (laboratory grade, 99%) , hypochloride 10 % 500 ml , hypochlorite (l) , hypochlorous acid (hocl – 0.003%) + sodium hypochlorite (naocl – 0.004%) + electrolysed water – 99.97% (wound care spray) – 500 ml , hypochlorous acid (hocl – 0.008%) + sodium hypochlorite (naocl – 0.002%) + electrolysed water – 97.64% (wound care gel) – 60 gm. , ice bucket each , iga 100 ml , ige calibrator 100 ml (compactible with dirui cst240) , ige reagent 100 ml (compactible with dirui cst240) , igg 100 ml , igm 100 ml , imidazole , imipenem (antibiotic disc)10mcg (250 disc) , imipenem relebactum(antibiotic disc)10 mcg (250 disc) , imipenem relebactum(antibiotic disc)25mcg (250 disc) , immunoassay controls (more than > 30 parameters) 5 ml , immunohistochemistry (ihc) estrogen receptor kit (a all in one kit for immunohistochemical staining for tissues, it must contain primary antibody, secondary antibody, conjugates, buffer and all necessary reagents.) , immunohistochemistry (ihc) her2 receptor kit( a all in one kit for immunohistochemical staining for tissues, it must contain primary antibody, secondary antibody, conjugates, buffer and all necessary reagents.) , immunohistochemistry (ihc) progesterone receptor (pr) (a all in one kit for immunohistochemical staining for tissues, it must contain primary antibody, secondary antibody, conjugates, buffer and all necessary reagents.) , immunology controls including (crp/aso/rf) 5 ml , india ink – 100 gm , india ink 100 ml , indian ink 250 ml , inhibin 1 ml , innovative tenside system containing 5 15% anionic surfectants, < 5 % nonionic surfectants, <5% polycarboxylate, enzymes.other excipients: solubiliser, corrossion inhibitors sodium cumenesulfonate, sodim etasulfate, 2 aminoethanol, alcohols, c13 15 branched and linear, butoxylated ethoxylated, alkylpolyethylen glycol polybutylen glycolether, subtilisin, glucerol, pack size: 5 litre jar , iodine 500 gm , iodine apex 100 gm , iodoacetamide (iaa) , iron alum 5% 100 ml , iron binding kit 150ml , iron sulfite agar , iron tibc 100 ml , iso amyl alcohol 500 ml , iso butanol , isoniazid / isonicotinyl hydrazine 1mcg (250 disc) , isopropanol 1000ml(acs purity 69 71 %) , isopropyl alcohol 2.5 ltr c3h80 [ mol. wt. = 60.10 ] specification: assay ( gc ) nlt = 99.0% weight per ml at 20°c = 0.784 0.786 maximum limits of impurities. residue after evaporation = 0.002% water = 0.2% , isopropyle alcohol(molecular grade)2.5 ltrs , itraconazole (mic e test strip) , itraconazole powder (solubilized powder, g irradiated ) 1 mg (250 disc) , japanese encephalitis igm elisa 1 x 96 , kanamycin(antibiotic disc)30mcg (250 disc) , karyotyping media (500ml) (ready to use liquid media, to be used to culture peripheral blood lymphocytes, 1x preparation, must supplemented with fetal bovine serum, l glutamine, and phytohemagglutinin, media use must be certified for “in vitro diagnostic use”. it should be manufactured at fda registered cgmp compliant facility only.) , kel 500ml , ketoconazole powder (solubilized powder, g irradiated ) 1 mg (250 disc) , ketone bodies ( blood) with calibrator 100 ml (compactible with dirui cst240) , ki67 antigen 1 ml , kovac’s indole reagent 250 ml , kovacs reagent – 100 ml , l spreader , l arginine hydrochloride 10 gm , l j media slant (solid media) 250 gm , l j media slant each , l lysine hydrochloride 10 gm , l shaped wire each pack , l.d test kit (rk39) – 100 tests , l.d test kit (rk39) – 25 tests , l.d test kit (rk39) – 50 tests , lab coat , lab goggles each , lab shoes size 10 , lab shoes – size 7 , lab shoes size 8 , lab shoes size 9 , laboline , laboratory deodorizing pearls , lactate control 100 ml (compactible with dirui cst240) , lactate with calibrator 100 ml (compactible with dirui cst240) , lactic acid , lactophenol cotton blue 250 ml , lactose 500 gm , lactose broth , lactose powder250 gm , lactose ttc agar with tergitol 7 , large ruler metallic scales each , l arginine hydrochloride 10 gm , lavofloxacin 5 x 250d , lb broth (lennox) , lb broth with agar , ldh kit – 2x25ml , ldl cholesterolcalibrator 100 ml , ldl control 50 ml , lead acetate 500 gm , leeming notman agar 250 gm , leeming notman agar 500 gm , leica freezing media for cryostat ( 125 ml ) leicapack size 40z ( 118 ml ) optimal cutting temperature ( oct ) compound is formation of clear, water soluble glycols and resin, providing a solid matrix to specimen holder for consistent sectioning in a cryostat working temperature of 10°c below. specification: mol. formula = na2s2o4 mol. wt. = 1/4.11 assay ( iodometric ) = 85 87.5 iron ( fe ) = max. 0.002 % ( at the moment of batch analysis ) , leishman powder 25gm form = powder colour = dark green solubility solution in methanol turbidity 0.1 % clear solubility colour solution in methanol 0.1 % blue with green fluorescence loss on drying = max. 8 % absorbance ( a ) in 1 % solution in methanol in a 1cm cell at 650nm = min. 950 , leishman stain 500ml , leishman stain powder 100gm , leishman stain powder 250 gm , lens cleaner , leptospira igm elisa 1 x 96 (1 pack) , levofloxacin(antibiotic disc) 5mcg (250 disc) , liapase 100 ml , light green 2% 100 ml , light green for microscopy 25 gm absorption maximum ( ? max. water ) = 629 634 nm specific extinction ( e1% / 1cm ) ? max. = 0.0005 % water = 830 1130 loss on drying ( 110°c ) = 12% , light green powder 500 gm , light green sf yellow 25 gm , lignocaine hydrochloride 10 ml injection ip = 2% lignocaine hydrochloride ip 2% w/v sodium chloride = 0.45% w/v methyl paraben = 0.2% w/v water for injection ip q.s , lignocaine hydrochloride 20 ml , lincomycin 15 mcg (250 disc) , lincomycin 2 mcg (250 disc) , linezolid(antibiotic disc)30mcg (250 disc) , linezolid 10 mcg (antibiotic disc) (250 disc) , lipase, amylase, protease, cellulase, biodegradability 3.785 liter , lipid controls 5 ml , lipoporotein (a) – 5 ml , lipoprotein 100 ml , liquid paraffin (heavy) 500 ml , liquid paraffin light 500 ml guarantee analysis weight per ml at 20°c = 0.84 0.89gm refractive index at 20°c = 1.480 identification ( by ir ) = passes test , liquor ammonia 500 ml , listeria enrichment broth (base) , listeria innocua , listeria monocytogenes , lithium carbonate 100 ml , liver broth , l lysine hydrochloride 10 gm , l mould brass – specimen holder used for holding the wax block for taking sections on the microtome.( size – 7.5 × 3 × 1.9 cm pair) , l mould brass – specimen holder used for holding the wax block for taking sections on the microtome. (size – 4.5 x 2.5 x 0.5 cm pair) , lomefloxacin 10 mcg , loop (1 mm) each pack , loop (10mm) each pack , loop (2mm) each pack , loop (4mm) each pack , l ornithine hydrochloride 10 gm , lpa 100 ml , l threonine , l tyrosine , lugols iodine 100 ml , lugols iodine 250 ml , lugols iodine 500 ml , l valine , lysozyme , m.p. test kit (pv, pf) –100 tests , m.p. test kit (pv, pf) –50 tests , m.p. test kit (pv, pf) – 25 tests , mac cartney bottle with screw cork , mac conkey agar 500 gm , macconkey broth , macconkey sorbitol agar500 gm , magnefying glass 3 each , magnesium chloride (mgcl2) 100 gm , magnesium chloride (mgcl2) 500 ml , magnesium chloride hexahydrate , magnesium powder 500 gm , magnesium sulphate 500 gm , magnesium sulphate heptahydrate , malachite green 100 gm , malaria elisa 96 w , malt extract , maltose 500 gm , mangenese chloride , mannitol egg yolk polymyxin (myp) agar , mannitol salt agar , manual cell counter with 9 keys for dlc – differential blood cell counter 9 windows total of keys8 or 9 keys total of windows 2 (totalaizer) each window figure range:0 999 number of buttons 8 number of windows 9 dimensions (mm)w320xd80xh50 , masson trichrome stain reagent , mathicilin : 5x50 t , mayer’s hemalum solution 1 ltrs specification: density = 1.05/cm3 ( 20°c ) ph = 1.8 2.2 ( 20°c ) ci752904.4gm/l al2(so4)3 18h20 = 28gm/l c6h8o7h2o = 0.5 gm/l , mayer’s hemetoxylene solution 1 gm , mc cal a ( mastercurve calibrator a ) 100 ml , mc grunewald stain 500 ml , mdm 2 1 ml , measles igm (ab) elisa 1 x 96 , measuring jar 500 ml , measuring scoop each , mecillinam 10 mcg (250 disc) , melan a 1 ml , m endo agar , mercuric chloride 500 gm , mercuric oxide red 100gm inorganic chemical assay = 99 % appearance ( form ) = solid colour = red purity = 99 % mol. wt. = 216.59 grade ar/gr melting point = 500°c , mercuric oxide red 500gm , mercuric sulphate 500 gm , meropenem (antibiotic disc)10mcg (250 disc) , metanil yellow 500 gm , methanamine 3% 500 ml , methanamine silver 100 ml , methanol – 500 ml , methanol ( methyl alcohol ) 2.5 ltrs minimum assay 99.8 % maximum limit of impurities • colour = 10 hu • water = 0.1 % • acidity ( hcooh ) = 0.001 % • alkalinity ( nh3 ) = 0.0002 % • non volatile matter = 0.001 % • aldehydes and ketones = 0.005 % • ethanol = 0.1 % • copper = 0.00005 % • lead = 0.00005 % • iron = 0.0001 % • permanganate = 0.00025 % , methyl alcohol 5 ml , methyl blue 25 gm , methyl green 250 gm , methyl red indicator – 250 ml , methyl violet/ crystal violet powder 250 gm , methyl violet/ crystal violet powder 500 gm , methyl violet/ crystal violet solution 100 ml , methyl violet/ crystal violet solution 250 ml , methyl violet/ crystal violet solution 500 ml , methylene blue (aqueous) 100 ml , methylene blue 100 gm , methylene blue 250 gm , methylene blue 500gm , methylene blue new 100 ml , methylene chloride 250 ml , methylene green 100 gm , metronidazole 5 mcg (250 disc) , metronidazole 80 mcg (250 disc) , mezlocillin 30 mcg (250 disc) , mezlocillin 75 mcg (250 disc) , m fc agar , mg powder 500 g , micafungin (mic e test strip) , micafungin powder (solubilized powder, g irradiated ) 1 mg , michel’s transport media , micro albumin control level 1 100 ml (compactible with dirui cst240) , micro albumin csf/urine 100 ml , micro albumin with calibrator 100 ml (compactible with dirui cst240) , micro clean 1 ltr. , micro protein control level 1 100 ml (compactible with dirui cst240) , micro protein kit , micro protein with calibrator 100 ml (compactible with dirui cst240) , milk agar , minocycline(antibiotic disc)30mcg (250 disc) , modified charcoal cefoperazone deoxycholate agar (mccd) , modified dixon agar 250 gm , modified dixon agar 500 gm , modified mha500 gm , molecular grade h2o – 500 ml , molecular ladder 100bp , mollecular ladder 1kb , molybdic acid 500 ml , motility test media , moxalactum(antibiotic disc)30mcg (250 disc) , moxifloxacin 5 mcg (antibiotic disc) (250 disc) , mpo staining reagent – benzidin power 250 gm , mr reagent 100 ml , msa (mannitol salt agar) media 250 gm , msa (mannitol salt agar) media 500 gm , mtt tetrazolium , mueller hinton agar 500 gm , mueller kauffman tetrathionate novobiocin broth base (mkttn) , multi calibrator antibiotic tdm 100 ml , multi enzyme cleaner with neutral ph containing5 15% non ionic surfactants, enzymes (amylase, lipase & protease), fragrancessolubilisers, corrosion inhibitors, colouring agents. declared conformity as medical device according to mdd93/42/eec.alcohol, c13 c15 branched and linear, butoxylated ethoxy, ethanol, alkyl polyethylenglycol polybutylenglycolether, sodium cumenesulfonate, pack size: 2 litre bottle , multidet kit 1000ml , multienzymatic cleaner, jar manufacturer / marketing company should be certifying according to din en iso 9001, 14100 & 13485 certificate , multipurpose labelling tape , mumps igm (ab) elisa 1 x 96 , mupirocin 200 mcg (250 disc) , mupirocin 5 mcg (250 disc) , myo d1 1 ml , myogenin 1 ml , myoglobin 1 ml , myoglobin 100 ml , myoglobin calibrator 100 ml , n acetyl l cystine (nalc) 10 gm , n,n dimethyl form amide (sigma d 4551) – 500 ml , n,n,n,n tetramethylethylenediamine (temed) , n,n’ methylene bis acrylamide , n.a. agar , n 1 nepthyl ethylenediamine dihydrochloride (100g) (acs reagent, >98.0%) , na + k standard solution 100 ml , na+ & k+ standard solution 500ml , nadp 100mg (purity (hplc) > 95 %/spectrophotometric purity > 95 %) , nadph 100mg (powder, =97% (dry weight), mol wt.833.4) , nafcillin 1 mcg (antibiotic disc) (250 disc) , nalc 10 gm , nalidixic acid (antibiotic disc) 30mcg (250 disc) , naphthol a s phosphate (sigma n 5625) – 500 ml , natidixic acid (antibiotic disc) p. size 5x 250 , n butanol 500 ml , n butyl alcohol 500ml , negative calibrator dau 100 ml , neomycin 30 mcg (antibiotic disc) (250 disc) , neomycin 5 mcg (antibiotic disc) (250 disc) , netilmicin(antibiotic disc)30mcg (250 disc) , neubauers counting cover slip each , neuron specify enalase , neutral red (0.62% aquor solution) – 500 ml , neutrophil alkaline phosphate reagent , nh3 control 1 100 ml (compactible with dirui cst240) , nh3 control 2 100ml (compactible with dirui cst240) , nh3 reagent 100 ml (compactible with dirui cst240) , nigrosin powder–250 gm , nigrosin powder– 100 gm , ninhydrin 10 gm , nitric acid 500 ml , nitric acid (conc) 500 ml , nitrofurantoin (antibiotic disc)300mcg (250 disc) , nitrofurantoin 100 mcg (antibiotic disc) (250 disc) , nitrofurantoin 200 mcg (antibiotic disc) (250 disc) , nitrofurantoin 50 mcg (antibiotic disc) (250 disc) , nlgrosln stain – 25 gm , no foam reagent 100 ml , norfloxacin 2 mcg (antibiotic disc) (250 disc) , norfloxcin (antibiotic disc)10mcg (250 disc) , normal saline 500 ml , norovirus, stool, antigen, ridascreen; r. biopharma , novacastralhc detection kit 1250 x 1 , novobiocin disc (antibiotic disc)10mcg (250 disc) , novoline polymer 1kit , nse 1 ml , nuclear fast red 100ml , nuclease free water or diethylpyrocarbonate (depc) 5 ml , nutrient agar 500 gm , nutrient agar 1000 gm , nutrient broth , nutrient gelatin , o. toluidine – 200 gm , o.g.6 powder 25 gm , occult blood test kit immunochromatography 25tests , octenidine based wash lotion with neutral ph, tested as per european norms containing octenidine hcl, aqua, cocamidopropylamine oxide, peg 7 glyceryl cocoate, glycerin, hydroxyethyl cellulose, lactic acid, contains allantoin, for full body wash head to toe, pack size: 500 ml bottle , octenidine based wash mitts with pratical hand dimension, tested as per european norms containing octenidine hcl,aqua, glycerine, cocamidopropylamine oxide, sodium lactate, allantoin,ethylhexyl glycerine, pack size: 100 pcs per packet , ofloxacin (antibiotic disc) 10mcg (250 disc) , ofloxacin 5 mcg (antibiotic disc) (250 disc) , oilminth peperment , oleandomycin 10mcg (antibiotic disc) (250 disc) , oleandomycin 15 mcg (antibiotic disc) (250 disc) , oleic acid (5g) ()purity (gc) > 99 % _cell culture test pass , onpg disc100 disc (250 disc) , ophyde 5 ltrs , optochin disc (antibiotic disc) 5mcg (250 disc) , orange g 100gm , orange g 25gm appearance = orange coloured powder form solubility ( turbidity )0.1% aqueous clear solution loss on drying = max. 10 % absorbance of 1 % aqueous solution in a 1cm cell vs h20 @478nm = 380 500 , orange serum agar , orcein 200 ml , ornithine dec arbovylace test reagent , ortho phosphoric acid , orthotoluidine 20 ml , oxacillin(antibiotic disc)1mcg (250 disc) , oxacillin 5 mcg (antibiotic disc) (250 disc) , oxalate powder 250gm , oxalic acid 500 gm , oxalic acid 2% 500 ml , oxford listeria selective agar , oxford listeria selective supplement , oxidase reagents disc 1 pack (pack of 100 discs) , oxidase reagents powder 250 gm , oxidative/fermentative medium with “ferric chloride” reagent 250 ml , oxolinic acid 2 mcg (250 disc) , oxytetracycline 30 mcg (250 disc) , p 120 1 ml , p 53 1 ml , p 63 1 ml , p.h. liquid handicator , p.p.d. 10 tu 5ml , p.p.d. 2 tu 5ml , p.p.d. 5 tu 5ml , p.t kit prothrombin kit (isi value = 1.1 liquid stable) 5ml , palcam listeria selective agar , palcam listeria selective supplement , pals solution 100 ml , pan cytokeratin 1 ml , panta 15 ml , pap staining kit , paper auto clave print paper sheets , paper butter paper each , paper cellulose acetate paper for electrophoresis each , paper eto thermal printing paper sheets , paper filter paper – 25 pcs. , paper litmus paper blue – each , paper litmus paper red – each , paper ph indicator paper pack of 100 , paper r.a. printing paper each , paper sample appicafor for cellulose acetate paper electrophoresis each , paper thermal paper 4.2” 50 mtrs , paper tissue paper – the tissue paper is hygienic, soft to touch, and highly absorbent. disposable 100 pcs/ pack , paper water filter papers 100 leaves , paper whatman filter paper no2 , paraffin liquid 500ml , paraffin sealing strip/tapeeach pack , paraffin wax (granules) – 500 gm. , paraffin wax = 2 kg 58 t0 60°c specification: alkaline/acid reacting substance passes test solidification point = 58 60°c ulphated ash =0.05% suitability for histopathology passes test. , parafilm dispenser with cutter each , paraformaldehyde , parvo b 19 igm (ab) elisa 1 x 96 , pas and diastase enzyme 100 ml , pasture pipette with rubber , pax 5 1 ml , pbs buffer 1x 500 ml each , pbs buffer 1x 6ml , pcr – primer for thalassaemia & sickle cell anamia – 500 ml , pcr buffer 2x 25ml each , pcr buffer 2x 500 ml each , pcr buffer 5x 500 ml each , pcr buffer 5x 25ml each , pcr grade water 100 ml , pcr microplate with septa 48 well (polypropylene pcr microplate compatible with standard pcr machine, non skirted, clear, should be supplied with compatible plastic septas) , pcr microplate with septa 96 well (polypropylene pcr microplate compatible with standard pcr machine, non skirted, clear, should be supplied with compatible plastic septas) , pcr plate 0.1 ul , pcr plate 0.2 ul , pcr plate 96 well , pcr plate clear sealing films 96 well (100 per pack) (functional temperature range 40 to +104 °c) , pcr plate cover 0.1ul , pcr plate cover film 0.2 ul , pcr plate flexi – 96 well , pcr primer (100 oligonucleotides, average 20b/oligo) labelled with fam (fam dye labelled customized oligonucleotidess for pcr reaction) , pcr primer (100 oligonucleotides, average 20b/oligo) labelled with hex (hex dye labelled customized oligonucleotidess for pcr reaction) , pcr primer (100 oligonucleotides, average 20b/oligo) labelled with rox (rox dye labelled customized oligonucleotidess for pcr reaction) , pcr primer (100 oligonucleotides, average 20b/oligo) labelled with tamara (tamara dye labelled customized oligonucleotidess for pcr reaction) , pcr primer (100 oligonucleotides, average 20b/oligo) unlabelled (unlabelled customized oligonucleotidess for pcr reaction) , pd 1 50ul(40ug) , pda agar , peflox(imported) 5mcg (250 disc) , pefloxacin (antibiotic disc) 5 mcg (250 disc) , penicilin g(antibiotic disc)10 units (250 disc) , pepsin 1 gm , peptone 500gm , peptone water media 500gm , perchloric acid schiff(pas) kit , perfumed liquid based softening agent with anti static property and biodegradable having ph of 6.5 7.5 ltr. , periodic acid: 25gm specification: ph 1.2 ( 100gm/l, h2o,20 degree celsius bulk density – 1400kg/m3, assay( iodometric) >98.0%melting point (lower value) >124 degree celsius melting point (upper value) >129 degree celsius , periodic acid 0.5% 100 ml , periodic acid 1% 100 ml , peripheral blood karyotyping readymade culture media rpm1 16501 , peripheral blood karyotyping readymade culture media rpmi 1640 , perl’s staining reagent – potassium feno 250 ml , perls iron stain1 & 2 ( twin pack)specification a. perls 1 potassium ferrocyanide 250ml b. persl2 hydrochloric acid 250ml , petri disc 4” glass – each , petri disc 4” pvc – each , petri plate 100mm each , petroleum ether 250 ml , ph meter each , phenobarbital 100 ml , phenol red indicator 100ml , phenotoin 100 ml , phenyl hydrogen hydrochloride 95 % , phenyl phosphatedisodium salt , phenylalanine agar , phosphate buffer saline 120 ml , phosphate buffer saline 500 ml , phosphomolybdic acid 25 gm , phosphoric acid 500 ml , phosphorus 100 ml , phosphorus kit 50 t , phosphotungstic acid 100 gm , phosphotungstic acid 500gm specification: physical state at 20°c = solid appearance = white to yellowish powder or crystal odourless melting point / freezing point = 95°c solubility in water ( % weight ) = 200gm/100gm water substance insoluble in water = max. 0.01 % chloride = 0.01 % sulphate = max. 0.01 % total nitrogen = 0.005 % loss on ignition at ( >50°c ) = max.17 % , picric acid (lyctophenol )250 ml , picric acid 500 gm , picric acid(saturated) 100 ml , pilocarpine 2% & 4% , pipemidic acid 20 mcg (antibiotic disc) (250 disc) , piperacillin (antibiotic disc)100mcg (250 disc) , piperacillin + tazobactum (antibiotic disc)100 (250disc) , piperacillin 100 mcg + tazobactam 10 mcg (antibiotic disc) (250 disc) , piperacillin 30 mcg (antibiotic disc) (250 disc) , piperacillin 30 mcg + tazobactam 6 mcg (antibiotic disc) (250 disc) , piperacillin 50 mcg (antibiotic disc) (250 disc) , piperacillin 75 mcg (antibiotic disc) (250 disc) , piperacillin 75 mcg + tazobactam10 mcg (antibiotic disc) (250 disc) , piperazine n,n’ bis(2 ethanesulfonic acid) , pipette –westerngren esr , pipette – autopipette 0.1 10 ul , pipette – autopipette 1 200 ul , pipette bulb each , pipette – disposable pipette single , pipette – graduated pipettes 10 ml , pipette – graduated pipettes 1ml , pipette – graduated pipettes 2 ml , pipette – graduated pipettes 5 ml , pipette – hemoglobin pipette each , pipette – pasteur pipettes with rubber blubs each , pipette – pipette stand(it should be madeup of polymethyl methacrylate, atleast 5 places for pipettes) , pipette – r.b.c. pipette (german) pcs , pipette sterilized pasture pipette each , pipette – sterilized pasture pipette with rubber each , pipette variable pipette: micropipette, adjustable volume, fully autoclavable eight channel : 05 50 ul, 30 300ul & 100 1000ul , pipette variable pipette: micropipette, adjustable volume, fully autoclavable single channel : 01 10ul, 02 20ul, 05 50ul, 10 100ul, 20 200ul, 100 1000ul spring loaded tip cone for connecting tips very tightly, adjustment opening for adjusting pipettes to a specific liquid and volume. control button with very low operating force, color indication for pipette volume. tip ejector with very low operating force, positioned for perfect ergonomics. volume display: 4 digits with magnifier. to provide thermal, mechanical and chemical stability piston should manufactured from fortro material very easy removable lower part for cleaning pipette no discoloration upon uv irradiation. confirmation to specification must , pipette w.b.c. pipette (german) pcs , plastic cassettes for automatic tissue processer – 500 ml , plate elisa plate 96 well , plate microtitre plate with lid 96 well flat bottom , plate microtitre plate with lid 96 well round bottom , plate count agar , platelet count fluid 2.5 ltrs , platelet count fluid 500 ml , platelet diluting fluid 125ml/bottle , poatato dextrose (pda)agar , poivceu red staining solution 500 ml , pollyf (cement) , polyclonal rabbit anti human c1q complement/fitc one kit(2ml concentrated) (the reagent should be used for demonstration of human c1q in tissues, and may also be used for other immunofluorescence techniques. the anti human c1q complement conjugate should be prepared from a purified immunoglobulin fraction of rabbit antiserum. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity. the shelf life must be 7 9 months at the time of delivery. the antibody should be compatible with manual and automated system. demonstration should be performed before supply of purchase order.) , polyclonal rabbit anti human c3 complement/fitc one kit(2ml concentrated) (the reagent should be used for demonstration of complement c3 in tissues, and may also be used for other immunofluorescence techniques. the complement c3 conjugate should be prepared from a purified immunoglobulin fraction of rabbit antiserum conjugated with fluorescein isothiocyanate isomer 1. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. the antibody should react with human c3 c part of c3 and c3b. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity.) , polyclonal rabbit anti human fibrinogen/fitc one kit (2ml concentrated) (the reagent is intended for demonstration of human fibrinogen in tissues, and may also be used for other immunofluorescence techniques. the fibrinogen conjugate should be prepared from a purified protein fraction of rabbit antiserum. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity. the shelf life must be 7 9 months at the time of delivery. the antibody should be compatible with manual and automated system. demonstration should be performed before supply of purchase order.) , polyclonal rabbit anti human iga/fitc one kit(2ml concentrated) (the reagent is intended for demonstration of human immunoglobulins in tissues, and may also be used for other immunofluorescence techniques. the anti human iga conjugate should be prepared from a purified immunoglobulin fraction of rabbit antiserum. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity. the shelf life must be 7 9 months at the time of delivery. the antibody should be compatible with manual and automated system. demonstration should be performed before supply of purchase order.) , polyclonal rabbit anti human igg/fitc one kit(2ml concentrated) (the reagent is intended for demonstration of human immunoglobulins in tissues, and may also be used for other immunofluorescence techniques. the anti human igg conjugate should be prepared from a purified immunoglobulin fraction of rabbit antiserum. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity. the shelf life must be 7 9 months at the time of delivery. the antibody should be compatible with manual and automated system. demonstration should be performed before supply of purchase order) , polyclonal rabbit anti human igm/fitc – one kit(2ml concentrated) (the reagent is intended for demonstration of human immunoglobulins in tissues, and may also be used for other immunofluorescence techniques. the anti human igm conjugate should be prepared from a purified immunoglobulin fraction of rabbit antiserum. protein concentration must be labeled in g/l. antibody titre must be so that it could provide f/p ratio: e495 nm/e278 nm = 0.65 ± 0.05 corresponding to a molar fitc/protein ratio of >2.0. it should be compatible for frozen section and paraffin embedded tissues. should have high sensitivity and specificity. the shelf life must be 7 9 months at the time of delivery. the antibody should be compatible with manual and automated system. demonstration should be performed before supply of purchase order. , polyethylene glycol 6000 , poly l lysine 100mlsolution. 0.1% (w/v) in h20 p8920 , polymerase , polymeric biguanide hydrochloride inhouse greated then 10% alkyle dimethyle benzyle ammonium chloride and didecyle dimethyle ammonium chloride in house greater then 10% quantative nonporous surface test for the evolution of bactericidal and or fungicial antvity of chemicals , polymeric bigunide hydrocholide 10 % alkyl dimethyle benzyl ammonium chloride and dodecyl dimethyle ammonium , polymixin b 50 mcg (antibiotic disc) (250 disc) , polymixinb (antibiotic disc)300mcg (250 disc) , posaconazole (mic e test strip) , posaconazole powder (solubilized powder, g irradiated ) , pot urinary urine collector – material plastic colour blue/ white closure type screw pattern solid capacity 50 milliliters product dimensions 8w x 5h centimeters shape round , pot urine pot sterile, graduated, screw capped , potassium acetate 500 gm , potassium almunium sulphate 500 gm , potassium aluminium sulphate 100 gm , potassium carbonate (khco3) 500 gm , potassium chloride (kcl)500 gm (reagentplus®, =99.0%) , potassium citrate , potassium dichromate (powder) , potassium dihydrogen diphosphate 5 kg [ potassium po4 mono basic ) assay ( after drying ) = 99.0 101.0 % ph ( 5 % aqueous ) = 4.1 4.5 maximum limits of impurities • chloride = 0.01 % • sulphate = 0.05 % • iron = 0.002 % • heavy metals ( pb ) = 0.002 % • sodium ( na ) = 0.2 % , potassium dihydrogen orthophosphate , potassium dihydrogen phosphate gr (kh2po4) 500 gm , potassium ferrocyanide 2% 500 ml , potassium ferrocyanide 99% 500 gm , potassium hydroxide (koh) 250gm , potassium hydroxide (koh) 500gm , potassium iodide 500 gm , potassium iodide crystal 100 gm , potassium iodide crystal 200 gm , potassium nitrate – 500 gm , potassium oxalate 500 g , potassium periodate , potassium permanganate (acidified) 100 ml , potassium permanganate 500 gm , potassium peroxomono sulphate 5 kg (in house) (50% w/w) with 3rd party test report from reliable lab, or indian or european norm certificates , potassium phosphate di basic (k2hpo4) (250g)(bioultra, for molecular biology, =99.0%) , potassium phosphate monobasic(kh2po4) (500g) (acs reagent, =98%) , potassium thiocyanate 99% 500 gm , potassium thionate 100 gm , potato dextrose agar 500 gm , potato dextrose agar with chloramphenicol , povidone iodine ip (7.5 % w/v) 100 ml i.e. available iodine (0.75 % w/v , povidone iodine solution ip 5% w/v 250 ml available iodine 0.5 % w/v purified water ip q.s , povidone iodine ip 10 % w/v , (1.0 % w/v available iodine) u.s.p equivalent to 1% available iodine, <10% nonylphenol, <10% ethoxylated, <10% polyethylene glycol 400, <10% citric acid, <10% sodiumphosphate, 30 70% water, pack size: 500 ml bottle , povidone iodine ip 7.5 % w/v, (equivalent to 0.75 % w/v available iodine), 0 10% ammonium nonoxynol sulfate, 0 10% glycerol, 0 10% , sodium lauryl sulfate, 0 10% sodium phosphate dibasic, 0 10% hydroxyethylcellulose, 0 10% potassium iodide, >20% , water with emollient & moisturiser, pack size: 500 ml bottle , ppd 10 tu 10 ml , pre albumin 100 ml , pre albumin calibrator 100 ml , progestone receptor 3 ml , protease inhibitor , protein kit per kit , protein mw marker , protein, rust, coffee and ink spotting kit kit , proteinase k (powder) 100mg (100mg powder, to be used in dna isolation, molecular biology use only, source from pichia pastoris or tritirachium album activity unit per mg =30 ) , proteolytic enzymatic cleaner , proteolytic enzyme (proteas ) , instrument compatibility 1 ltrs , proteus mirabilis , prulifloxacin (antibiotic disc) 10mcg (250 disc) , prussian blue 500 ml , psa 1 ml , psa stain 100 ml , pseudomonas aeruginosa , pseudomonas agar base , pseudomonas cfc selective supplement , pseudomonas cn selective supplement , pseudomonas selective agar (cfc agar) , p toluidine , pt pcr zika rt pcr kit , pumic stone 500 gm , purified mercury 100 gm , qc for clinical chemistry 100 ml , quality control for clinical chemistry high , quality control for clinical chemistry normal , quinpristine dalfopristine(antibiotic disc)15mcg (250disc) , r.a. factor test(r.a. latex 100 t) 100 test , r.b.c diluting fluid 500ml appearance = clear colourless solution , r.b.c lysis solution 200 ml , r.c.m. media 250 gm , rack 96 well rack for mct tubes (for 2ml tube) (it should be made up of polycarbonate, must contain 96 places (8x12) for 1.5ml tube. ) , rack pcr rack with cover , rack pcr tube rack 96 set , rack pipette rack 6 pcs capacity , rack sample racks for sample tube each , rack sample racks for sample tube each , rack somersault rack universal each , rack staining rack staining jarincluding lids – 8 numbers slide rack 1 body type – stainless steel size – 47.5 x12.0x12.0 cm , rack steelrack – formicroscope slides slide staining rack is made of aluminium and stainless steel staining rack comes with movable handle. stainless steel slide rack is resistant to staining solutions. hinged rack handle allows easy insertion and removal of the microscope slides. slide staining rack holds up to 25 microscope slides. , rack steel rack – to hold 50 slides , rack test tube rack 24 tube , rack test tube rack (36 holes) alumunium , rack universal combi rack , rack test tube rack 36t , raffinose pentahydrate , rapid kit for c.difficile , rapid kit for h pylori 100 tests , rapid test kit for clostridium difficile pack of 50 test , rapid test kit for salmonella species pack of 50 test , rappaport vassiliadis soya peptone broth , rat repallent each , ravuconazolepowder (solubilized powder, g irradiated ) 1 mg , ready plate chromogenic coliform agar , reagent reservoir 200ml , reagent reservoir/ troughs autoclavable (polypropylene, 75ml, ) , reaty to use for drug assay methotrexate assay – 3.0 ml , reaty to use for drug assay phenobarbital assay 28ml with calibrator , reaty to use for drug assay phenobarbital assay 14 ml with calibrator , reaty to use for drug assay phenytoin assay 14 ml with calibrator , reaty to use for drug assay phenytoin assay 28ml with calibrator , reaty to use for drug assay valporic acid assay 14 ml with calibrator , reaty to use for drug assay valporic acid assay 28ml with calibrator , reaty to use for drug assay carbamazepine assay 14 ml with calibrator , reaty to use for drug assay carbamazepine assay 28ml with calibrator , rectangular staining jar – 10 in no. , red mercuric oxide 100 , red nucleic acid gel stain liquid (non mutagenic, non hazardous for disposal,highly stable and environmentally safe fluorescent nucleic acid dye for agarose gel electrophoresis) , reels auto clave tape reels , reels sterilization packaging reels 200 mtr 40 cmsreels , reels sterilization packaging reels200 mtrs 10 cmsreels , reels sterilization packaging reels200 mtrs 20 cmsreels , reinforced clostridial agar , resorcinol 50 g , ret search ii 1 ltr , reticulin stain kit 500 ml , reticulocyte counting fluid 250 ml blue coloured fluid solubility = miscible with water solubility test = passes test , rf 100 ml , rf latex calibrator 100ml , rhamnose disc , rhodamine b , riboflavin , rifampicin(antibiotic disc)5mcg (250 disc) , rifampicin 2 mcg (antibiotic disc) (250 disc) , rifampicin 25 mcg (antibiotic disc) (250 disc) , rifampicine 30 mcg (antibiotic disc) (250 disc) , rna extraction kit100 test , rna extraction kit50 test , rna extraction kit 250 test , rna zap pcr dna degradation solutions500 ml , rna later , rnase free water , rnase inhibitor 30 ml , rnase zap (250ml), cleaning agent for removing rnase , robo levels , rod glass rod each , roll bc robo 888 (thermal paper) 50 mm x 30 mm (robo roll) , roll tissue paper roll 15 mtrs , roll tissue paper rolls ( laboratory grade, 2 ply, 50 meter) , roll tsc priater carbon roll 5 (1/2) , roll tyvek roll – 10 ” rolls , roll tyvek roll – 15.5”rolls , roll tyvek roll – 6” rolls , rota virusfecal ag elisa 1 x 96 , rotary sealer nos. , rpmi 1640 for fungal testing 500 ml , rpr test kit – 100 test , rt pcr covid 19 rt pcr kit , rt pcr dengue serotyping rt pcr kit each , rt pcr h1n1 rt pcr 1 x 96 (1 pack) , rt pcr h3n2 amplification rt pcr 1 x 96 (1 pack) , rt pcr hpv rt pcr kit 1 x 96 t , rt pcr respiratory syncytial virus rt pcr 96 test , rt pcr rt pcr hbv dna viral load100 test , rt pcr rt pcr hcv rna viral load100 test , rt pcr superscript iii one step rt pcr kit – 100 r each , rt pcr zika rt pcr kit , rt pcr hbv dna viral load100 test , rt pcr hcv rna viral load100 test , rubber cork each , rubber for burette 3/8” , rubber teat round and large each , rubber teat each , rubber tubing 5/8” – each , rubella igg elisa 1 x 96 , rubella igm elisa 1 x 96 , ruler metallic scale inch and cm marking exactly on the ends measurement can begin at zero and scale at end for rule, stainless steel and round safety edge grinding and polishing and thicker side great value as 1 set of 3 length 6 inch to 24 inch material?stainless steel colour ?silver graduation range ?0 60 centimeters product dimensions ?61l x 2.5w centimeters , s 100 1 ml , sabroud dextrose agar 500 gm , sabroud dextrose agar with cap , saccharomyces cerevisiae , saccharose , safety goggle each , saffranin( prepared solution) 500 ml , saffranine 250 gm , safranine staining , salicylic acid 500 ml , salmonella poly o antiserum , salt1 kg. , sample cup 100 pc , sample processing cup each , sanidex opa withtest strip & deactivator, biodegradibility ,instrument compatibility report 5 ltr , saponin extra pure 100gm specification: mol. formula = na mol. wt. = na insoluble matter in water max. 0.1 % loss on drying ( 150°c ) = max. 10 % sulphated ash = max. 10 % microbial limits = passes test , saturated tartragine 500 ml , scaald mucosa sampler each , schiff reagent: 500ml specification : appearance clear colorless to slight pink colored physical state at 20 degree celsius liquid, ph<2density 1g/cm3,solubility in water(% weight) completely soluble , scrub typhus igm elisa 1 x 96 (1 pack) , sda 500 gm , sda 1000 gm , sda with cycloheximide 500 gm , selective enrichment secondary supplement for listeria , selective enrichment supplement for listeria , selective supplement for chromogenic listeria agar , selenite cysteine broth , selenite cystine broth base , serum copper kit 25ml , serum protein caibrator 100 ml , shelf life of 5 years 500 ml bottle , shikata orcein 100 ml , shoes cover 100 pc , sickle test kit 100 tests , sickle test kit 50 tests , silica gel for column chromatography 500 gm grade 60 120 mesh size, grade 100 200 mesh size, grade 230 400 mesh size, , silver allow 100 gm , silver nitrate 10% 100 ml , silver nitrate 5% 500 ml , sim media 250 gm , sim media 500 gm , slanetz and bartley medium , slide cavity slide for vdrl (24 wells) , slide concavity slide (one cavity) each , slide concavity slide (two cavity) each , slide double frosted slide 50pcs pkt , slide glass monocavity slide 25 mm x 75 mm x 1.3 mm each pack , slide glass slide – ground edges, refractive index isi 50 slides , slide microscope slides –(plain) 50 pcs clear glass ground edges 26x76 + 0/ 1 mm thickness – 1.35+ 0.1 mm 50 pcs/ pack , slide microscope slides –for i.h.c. each positively charge slides & positively charge slides hydrophilic treating with reagents such as aminosilane,poly l lysine or others , slide warming table , sma 1ml , sms wraps sheets 120 x 120cms sheets , sms wraps sheets 75 x 75cms sheets , soda lime 5 kg , sodium acetate 100 ml , sodium alphanaphthy phosphate 250 ml , sodium azide (nan3) 100 gm , sodium bicarbonate 500 gm • magnesium phosphate • deionized water • tungsto phosphoric acid hydrate • pas stain • pearl’s stain • mpo stain , sodium bicarbonate (nahco3) 150 gm , sodium carbonate (na2co3) 500gm(powder, =99.5%, acs reagent) , sodium chloride [ nacl ] 5 kg assay nlt = 99.9 % ph ( 5 % aqueous solution ) = 5.0 8.0 maximum limits of impurities • water insoluble matter = 0.003 % • bromide & iodide = 0.005 % • ferrocyanide = 0.0001 % • phosphate = 0.0005 % • sulphate = 0.002 % • total nitrogen = 0.001 % • arsenic = 0.00004 % • barium = 0.001 % • calcium = 0.002 % • iron = 0.0002 % • lead = 0.0002 % • potassium = 0.01 % • magnesium = 0.002 % • loss on drying = 0.5 % , sodium chloride 500 gm , sodium citrate500 gm , sodium citrate 3.2 % 500 ml , sodium citrate agar 500 gm , sodium deoxycholate 100 gm , sodium dichloroisocynanurate 500mg. excipeent q.s available chlorine 300mg, pack size: 50 tablets per bottle , sodium dichromate dihydrate , sodium dihydrogen phosphate 500gm , sodium dithionate 85 % extra pure 1 kg specification: mol. formula = na2s2o4 mol. wt. = 1/4.11 assay ( iodometric ) = 85 87.5 iron ( fe ) = max. 0.002 % ( at the moment of batch analysis ) , sodium dodecyl sulphate (sds) , sodium fauro cholate 500 ml , sodium fluoride powder 500 gm , sodium hydrogen sulphite , sodium hydroride 500 gm , sodium hydrosulphite(dithionite) 100 gm , sodium hydroxide (naoh) 500 ml , sodium hydroxide (naoh) 500 gm , sodium hydroxide based liquid alkali booster concentrate. ltr. , sodium hydroxide maximum 5% based bleaching agent 5 ltr. , sodium hydroxide pellets purified 500 gm , sodium hydroxide pellets purified 250 gm , sodium hydroxide(naoh) 500 ml , sodium hypochlorite solution 5 ltrs , sodium hypodiphosphate , sodium lauryl sulphate solution fo 94.haemoglobin estimation , sodium meta bi sulphate 500gm [ na2s2o5 , mol. wt. = 190.13] minimum assay ( iodometric ) = 95.0 % maximum limits of impurities • chloride = 0.1 % • iron ( fe ) = 0.01 % , sodium meta bi sulphate 65% based rinsing aid kg. , sodium nitrite 500gm(acs reagent, =97.0%) , sodium nitrite 500gmpowder or crystals (acs reagent, >96.99.0%) , sodium nitroprusside 100 gm , sodium nitroprusside 500 gm , sodium nitroprusside dihydrate for analysis 500 gmm = 297.95 g/mol specification: assay = 99.0 102.0 % substances soluble in water = 0.01 % chloride ( cl ) = 0.02 % sulphate ( so4 ) = conforms hexacyanoferrate ( iii ) = 0.02 % , sodium parborate monohydrate 50% w/w saniscop, 1 en 14561 bactericidal 2 ) en14562 pesticidal 3 ) en 13704 sporicidal 4 ) instrument compatibility report 5 ) en 14348 microbectericidal , sodium perborate monohydrate 50% w/w saniscop, 1) en 14561 bactericidal 2) en 14562 yeasticidal 3) en 13704 sporicidal 4) instrument compatibility report 5) en 14348 micobactericidal810 gm , sodium perchlorate (500gm) (acs reagent, >98.0%, in powder or chunk form) , sodium perchlorate monohydrate 500 gm , sodium phosphate dibasic (na2hpo4) (acs reagent, =99.0%) 500 gm , sodium phosphate dibasic dihydrate (na2hpo4) (250 gm) (acs reagent, =99.5%) , sodium phosphate monobasic dihydrate[ nah2po4 h2o ] assay nlt = 98.5 % ph ( 5 % aqueous solution ) = 4.2 4.6 maximum limits of impurities • chloride = 0.01 % • sulphate = 0.02 % • arsenic = 0.0001 % • iron = 0.002 % • heavy metals ( as pb ) = 0.0005 % • loss on drying ( 130°c ) = 21.0 24.0 % , sodium pyruvate , sodium taurocholate 500gm , sodium thiocyanate , sodium thioglycollate salt , sodium thiosulphate250 ml , sodium thiosulphate500 gm , sodium thiosulphate 2% 100 ml , sodium thiosulphate 5% 100 ml , sodium tungstate 250 gm , sodium tungstate dihydrate , solica get for thin layer chromatography 500 gm , soyabean casein digest agar (scda) , sparfloxacin(antibiotic disc)5mcg (250 disc) , spatula ayre”s spatula for cervical pap smear – sterile ayre spatula wood / plastic lenght: 18 cm / 18.8 cm individually packed in sterile pouch, in box of 100 , spatula sazaly – spatula with cyto brush (ratable 360deg) , spatula spatula chattaway 5” , spatula spatula one end flat , one endspour 12” , spatula spatula one end flat, one endspour 6” , spatula spatula both side 8” , spectinomycin(antibiotic disc) 100mcg (250 disc) , spiramycin 100 mcg (antibiotic disc) (250 disc) , spirit (burning ) 1 ltr , spirit (rectified) 500 ml , spirit alcohol5 ltrs , spirit lamp each , spirit lamp ss each , spirit(methylated) 500 ml , ssc 20 x buffer , stabilized formulation of hydrogen peroxide 10% v/v,silver 0.01% w/v for critical area fumigation and surface disinfection, non toxic, non irritating, eco friendly, pack size: 1 litre bottle , stabilized hydrogen peroxide (11 % w/v) diluted silver nitrate solution (0.01 % w/v) , staining reagent red panceaus stainer each , staining solution 500 ml , staining trough glass trough with cover, approx. 9 x 7 x 6.5 cm glass cover staining tray made of stainless steel staining tray made of stainless steel with extended handle staining trough , staining trough glass trough without cover glass cover staining tray made of stainless steel staining tray made of stainless steel with extended handle staining trough , staining trough( for bulk staining ) , staining trough plastictrough with cover, approx. 9 x 7 x 6.5 cm plastic cover staining tray made of stainless steel staining tray made of stainless steel with extended handle staining trough , stand e.s.r. stand 10 tube , stand loop stand each , stand pcr tube stand 48 pc , stand pipette stand 6 pcs capacity , stand test tube stand 12 tubes , stand test tube stand 24 tubes , stand tripod stand each , stand universal test tube stand 6 pcs capacity , staphylococcus aureus , starch 500 gm , starch sluble (acs grade) , steri pette xl , sterile connector for connnecting device each , sterilized yellow – 1000 pcs. , sticker 1500 sticker pack , stop watch – square design, plastic construction and lcd display show hour, minute, second, am / pm indicator, month, data, and day of the week select 12 or 24 hour user with chronograph stopwatches 1/100 second chronograph up to 23hours, 59 minutes, 59 seconds timer stopwatches alarm with 4 minutes snooze powered by one ag13 button cell (included) hourly chime function and alarm function are included nylon fabric neck strap for easy carrying split / reset, mode and start / stop buttons for convenient operation dial window material type: plastic dial display: digital , straight wire each pack , strains 250 ml , streptomycin (antibiotic disc)10mcg (250 disc) , streptomycin 300 mcg (antibiotic disc) (250 disc) , streptomycin 50 mcg (antibiotic disc) (250 disc) , strip tube retainer (should be certified dnase and rnase free, must hold 0.2ml 96 tubes or 12 strip tubes at a time ) , stromato lyser fba 5 ltrs , stromato lyser ffs 42 ml , stromatolyser fourth dl(4dl) 5 l , stroptozotocinz 500 gm , substrate for alp conjugated 2 ab tmb (3,3,5,5 tetramethylbenzidine) dab (3,3 diaminobenzine)tetrahydrochlor 5 gm , substrate for alp conjugated 2* ab nitro blue tetrazolium chloride (nbt) 1 gm , sucrose 500 gm , sucrose powder 250 gm , sucrose powder 500 gm , sudan black 500ml , sudan black b powder 250 gm , sudan black: 10gm specification: colour dark brown black, appearance (form) powder molar extinction coefficient @ 596nm ,min20,000 loss on drying max 5% , sudan black: 100gm , sudan black: 25 gm , sugar disc cellotrise 4% , sugar disc dulcitol 4% , sugar disc fructose 4% , sugar disc glucose 4% , sugar disc inositol 4% , sugar disc lactose 4% , sugar disc maltose 4% , sugar disc melibiose 4% , sugar disc ruffinose 4% , sugar disc sucrose 4% , sugar disc trehalose 4% , sugar disc xylose 4% , sulfadiazine 0.25 mcg (antibiotic disc) (250 disc) , sulfamethoxazole 23.75mcg (antibiotic disc) (250 disc) , sulfamethoxazole 23.75 mcg + trimethoprim 1.25 mcg (antibiotic disc) (250 disc) , sulfathiazole 0.25 mcg (antibiotic disc) (250 disc) , sulfisoxazole 0.25 mcg (antibiotic disc) (250 disc) , sulfolyser 5l , sulphosalic acid 500 gm , sulphosalicylic acid 500 gm , sulphur powder 500 gm , sulphuric acid (h2so4) 20 % 500 ml , sulphuric acid (h2so4) conc 500ml , sultax (cefoaximen + sulbactam) (antibiotic disc) p. size 5 x 250 , super mix 25ml each , supersensitive wash buffer 500 ml specification: concentrated wash buffer dilute 1 part with 19 parts deionised water. , swab stick – for pap smear 100 pcs , swab stick sterile swab stick with cover 100 pcs , syaptophysin 1 ml , syber safe(gel stain , dna) , sybr green pcr mix (500 reactions) , synaptophysin 1 ml , syphillis card , syphillis elisa 96 w , syringe filter (0 2) ul , system calibrator 100 ml , tank serological pipette tank , taq dna polymerase 500u (to be used in pcr reaction (500u minimum)) , taq polymerase each , tartaric acid 500 ml , t butyl alcohol 500ml , tcbs media 250 gm , tcbs media 500 gm , teicoplanin(antibiotic disc)30mcg (250 disc) , telithromycin 15 mcg (antibiotic disc) (250 disc) , tellurite cefixime supplement , temocillin 30 mcg (antibiotic disc) (250 disc) , temperature thermometer , ten parameter multistix for urinalysis 10 pack (100 strips/pack) specification 1. the pack size should be of 100 reagents strips per pack. 2. each reagents strips should be measure ph, specific gravity, protein, sugar, blood (both hemolyzed and non hemolysed), bilirubin, ketone, urrobilinogen, leukocytes, nitrite with or without ascorbic acid. 3.the reaction priniciple for each test should be accouding to the latest and validated testing method and as per recent advancement like peroxidase test for glucose, ehrlich test for urobiligone, fauchet test for bilirubin etc.4. each strips should be of long expiry.5. maximum analysis time for each reagent strips must be less than 2 minutes.6. the color production for every reaction will be bright enough so that analyzed adequately.7. the readings for every test must be provided in both semi quantitative and standad units.8. the color comparator provided with the pack should of standard quality with color shades exactly matching with what appears on the strips so that no discrepency between color of reagent strip and comparator will occur. , tetra methyl phenylene 250 ml , tetracycline (antibiotic disc) 30mcg (250 disc) , tetracycline 10 mcg (antibiotic disc) (250 disc) , tetracycline 5 mcg (antibiotic disc) (250 disc) , tetrathionate broth 500 gm , tetrazolium salt , thc 100 ml , thermofisher automated rna extraction kit , thiamin hydrochloride , thio urea 500gm , thioacetamide , thiosemicarbaxide 0.5 % 100 ml , thiosulfate citrate bile sucrose (tcbs) agar , thymol 1 kit , thymol blue 500 gm , tibc 150ml , ticarcilin (antibiotic disc)75mcg (250 disc) , ticarcilin –clavulanic acid (antibiotic disc)10mcg (250 disc) , ticarcilin –clavulanic acid (antibiotic disc)75mcg(250 disc) , tigecyclin (antibiotic disc)15mcg (250 disc) , tincture benzoin , tincture iodine , tips blue tips 500 pcs , tips filter tips 10 ul 100 ul , tips filter tips 10?l 96 tipes , tips filter tips 100 ul 1000 ul , tips filter tips 2 ul 10 ul , tips filter tips 20 ul 200 ul , tips filter tips 1000?l 96 tipes , tips filter tips 20?l 96 tipes , tips filter tips 200?l 96 tipes , tips filteredtips200 1000ul 96 t , tips sterilefiltered tips 01 10ul , tips sterilefiltered tips 02 20ul , tips sterilefiltered tips 100 1000ul , tips sterilefiltered tips 10 100ul , tips sterilefiltered tips 20 200ul , tips sterile filtered tips 1 50ul 96pc , tips sterile microtips (0.5 10ul) (clear pre sterile, nonfilter microtips) , tips sterile microtips (1000ul) (clear pre sterile, non filter microtips) , tips sterile microtips (20 200ul) (polypropylene, pre sterile, non filter, yellow microtips without tip box) , tips yellow tips – 1000 pc pack , tissue capsule /embedding cassette (large) , tissue capsule /embedding cassette (small) , tissue cassate leica 1000 pc , tissue embedding cassette – (large ) made from acetyl polymer resistant to histological solvents non cytotoxic, non metallic colors storage temp. room temp eachmeasures: 3x2.5x0.4 cm. , tissue embedding cassette – (small)made from acetyl polymer resistant to histological solvents non cytotoxic, non metallic colors storage temp. room temp each slot measures: 1 x 5 mm, total 128 slots per cassette , tissue freezing media 200 ml , titriplex , tobidine blue 250 gm , tobramycin (antibiotic disc)10mcg (250 disc) , toluene 250 ml , toluidine blue 100ml , torniquate 1 meter , total iron kit 150ml , total protein kit3 x 150ml , total protien csf / urine 100 ml , total rna isolation from blood(50 reactions) , tough spots assorted colours , toxo igg elisa 1 x 96 (1 pack) , toxo rapid igg/ igm 50 tests , transferin 1 kit , tray draining tray it should be madeup of polycarbonate, autoclavable, dimention should be (mm) 400x300x100 (lbh) , tray ice tray each , tray slide tray , tray tray 3000ml , tray utility tray each , tri sodium citrate dihydrate purified 250 gm , tri sodium citrate dihydrated purified 500 gm , tributyrin agar , trichlorgacetic acid 500 ml , trichloro acetic acid (250g) (acs reagent, =99.0%) , trichrome stain( masson kit): specification : aniline blue solution 250mlbiebrich scarlet acid fuschin solution 250ml phosphomolybdic acid solution 250ml phosphotunngstic acid solution 250ml , trifluoroacetic acid , triglyceride kit 2x150ml , triglycerides 100 ml , trimephoprim(antibiotic disc)5mcg 250 disc , trimolol 0.25% , trimolol 5% , triphicasepepten 250 gm , triple sugar iron agar 500 gm , tripple enzymatic cleaner , tris base 500 gm , tris buffer 500 g , tris buffer (0.2 mol/l)plt 9.0 – 500 ml , tris hydrochloride 100 gm , tris hydrochloride 250 gm , tris powder (500gm) (acs grade, for molecular biology use) , tris chloride 500gm , tris saturated phenol , triton x 100 , trizol (500ml) (to be used for isolation of rna, dna, and protein ) , troporine i stripe 10 t , trypsin powder 250 gm , tryptic soya broth , tryptone broth , tryptone soya yeast extract agar , tsi 1000 gm , tsi 250 gm , tsi 500 gm , tube 15 ml falcon tubes(sterile, conical bottom, autoclavable,medical grade pp/hdpe confirming to usp class vi) , tube 50 ml falcon tubes (sterile, conical bottom, autoclavable,medical grade pp/hdpe confirming to usp class vi) , tube acd buffer tubes (9ml yellow capped tube filled with acd buffer (anticoagulant) to be used for blood collection) , tube blood rna tube (blood transport tubes for rna stability, containig 50 tubes per pack) , tube capillary tube 100pcs pack , tube centrifuge tube 10 ml , tube centrifuge tube 15 ml , tube conical falcon graduated 15 ml each , tube conical falcon graduated 50 ml each , tube culture tube 10 x 100 mm – each , tube cylindrical glass tubes for column chromatography each , tube dreyers tube 500pcs , tube durhams tube 1inch size 1000 pcs , tube felix tube 500 pcs , tube hemoglobin round tube each , tube hemoglobin square tube – each , tube hemoglobin tube (german) pcs , tube id sample tube 96w , tube kahn test tube 100 pcs pack , tube mcfarland tube with autoclavable cork , tube microcentrifuge tube 0.5ml (sterile, clear, should have frosted cap surfaces for labeling) , tube microcentrifuge tube 1.5ml (sterile, clear, should have frosted cap surfaces for labeling) , tube microcentrifuge tube 2.0ml (sterile, clear, should have frosted cap surfaces for labeling) , tube microcentrifuge tube amber microcentrifuge tubes 1.5ml (sterile, brown color mct tubes) , tube pcr 0.2 ml strip tubes with cap (8 tube strip)(it should be madeup of polypropylene, each strip should contain 8 tubes, must supplied with separate domed cap strip ) , tube pcr strips tubes (200 ul) with flat caps [500 strips]( packs)(polypropylene pcr tube, 0.2ml, 8 tubes/strip, dome caps should be supplied separately (not attached to the tubes)) , tube pcr tube with cap 0.1ml– 100 pc , tube pcr tube with cap 0.2ml – 100 pc , tube pcr tube with caps 0.1ul strip , tube pcr tube with caps 0.2ul strip , tube robo tube each , tube test tube size – 12 x 75 mm 100 pc pack size , tube test tube size – 12x 100 mm 100 pc pack size , tube test tube size – 13 x100 mm 100 pc pack size , tube test tube size – 15 x125 mm 100 pc pack size , tube test tube size – 16 x150 mm 100 pc pack size , tube test tube size – 18 x150 mm 100 pc pack size , tube test tube size – 20 x150 mm 100 pc pack size , tube test tube size – 25 x150 mm 100 pc pack size , tube tissue carrier rna tube , tube treated tubes , tube tube with transparent label 1000 each , tube wintrobetube , tube leveler , tween 20 100ml , tween 80 100 ml , typhidot igm test kit 50 tests , typhidot test (rapid test kit) for typhoid fever 50 test , udp glucose (250mg) (% purity (hplc) > 98) , uibc 100 ml , uracil dna glycosylase(1 vial of 1 unit/ ul 200 ul) , urea 100 ml , urea 250 gm , urea 500 gm , urea kit 2x150ml , urea solution 40 %5ml , uric acid 100 ml , uric acid kit 2x150ml , urinalysis control 5 ml , urine calibrator 100 ml , urine chemistry control 5 ml , urinometer each , uristrix 100 t , uv safety goggles 96w , valproic acid 100 ml , vancomycin(antibiotic disc)35mcg (250 disc) , vancomycin powder 50gm , varicella zoster igm (ab) elisa 1 x 96 , vial bomin vial 10 ml each , vial cryo vial 1.0 ml 1000 pcs 1pkt , vial cryo vial 1.8ml (each pack 500 vials) , vial cryo vial 5ml 500 pc , vial disposable vial – 100 pcs. , vial edta vial (vaccum) 100 pcs. , vial edta vial(non vaccum) 100 pcs , vial fluid vial 100 pcs , vial lithium heparin vacutainer (green) 100 pcs , vial plain (red non vaccum) 100 pcs , vial plain vial 100 pcs pack , vial plain vial 5 ml glass 100 pcs , vial plain vial(white) 5 ml 100 pcs pack , vial proteinase k 20 mg ( vial) , vial ria vial each , vial s.s.t tubes (yellow/ gold) 100 vials , vial sodium citrate 3.8% vial (e.s.r non vaccum) 100 pcs (black) , vial sodium citrate 3.8% vial (e.s.r vaccum) 100 pcs (black) , vial vacutainer with transparent level(yellow): gel 100 pcs , vial vacutainer with transparent level: oxo – flo/glucose (grey) 100 pcs , vial vacutainer with transparent level: plain (red) (clot activator) 100 pcs , vial sodium citrate 3.2 % vial (ptinr) 100 pc (sky blue) , victoria blue 1.5 % 500 ml , vimentin 1 ml , violet red bile glucose agar , von kossa stain 100 gm , voriconazole powder (solubilized powder, g irradiated ) , vortex , vp reagent 100 ml , vtm / utm 96 w , w.b.c diluting fluid 500ml appearance = bluish violet coloured physical state @ 20°c = liquid odourless ph = 2.5 3.5 absorption max. 588 594 nm absorption ( ? max. diluted 1.25, 1cm ) = 0.450 0.600 , wash concentrate 100 ml , wash solution 5 ltr , weigerts iron hematoxylin 25 gm , west nile igm elisa 1 x 96 , white petroleum jelly (white vaseline) 100 gm , white petroleum jelly (white vaseline) 250 gm , whole blood extraction kit 250 test (1 pack) , widal antigen( for tube method ) 4x100ml , widal antigen (for slide test) 4x100ml , wipes 0.5% ahp based high level surface disinfectant tuberculocidal wipes wipes , wipes kim wipes each , wipes tissue wipes ( big towels packs) (size 37cm x 42cm. should be made from 100% virgin fiber,low lint and low extractable. for sensitive instrument/lens cleaning.) , wipes tissue wipes ( small towels packs) (size 21cm x 11cm. should be made from 100% virgin fiber,low lint and low extractable. for sensitive instrument/lens cleaning.) , x ray developer 1 kg , x ray fixer 1 kg , xld media 500gm , xtum (ceftriaxone + sulbactam) (antibiotic disc) p. size 5 x 250 , xylene 2.5 ltrs (specification: boiling range (95%) = 137°c 142°c weight per ml at 20°c = 0.850 0.865 nvm = 0.01% max. solution in alcohol = clear) , xylene 250 ml , xylene 500 mlc6h4(ch3)(specification: boiling range (95%) = 137°c 142°c weight per ml at 20°c = 0.850 0.865 nvm = 0.01% max. solution in alcohol = clear) , xylene cyanol 10 gm , xylocaine 2% 25 ml , yeast nitrogen base 500 gm , zinc chloride , zinc oxide 500gm , zinc powder 500gm , zinc sulphate 500gm , zn stain fast kit 250 ml , zymokeen ltr. , list of reagents (dedicated system pack for erba em 360) fully automatic biochemistry analyzer (instruction : all parameters should be quotedby bidder) , glucose 100 ml , urea 100 ml , creatinine (enzymatic) 100 ml , uric acid 100 ml , total bilirubin 100 ml , direct bilirubin 100 ml , sgpt 100 ml , sgot 100 ml , lipase 100 ml , amylase 100 ml , alkaline phosphatase 100 ml , total protein 100 ml , albumin 100 ml , calcium 100 ml , phosphorus 100 ml , total cholesterol 100 ml , hdl cholesterol 100 ml , triglyceride 100 ml , direct ldl cholesterol 100 ml , iron 100 ml , ferritin with calibrator 100 ml , ferritin control level 1 100 ml , ferritin control level 2 100 ml , uibc/tibc 100 ml , ck nac 100 ml , crp quantitative with calibrator 100 ml , rf quantitative with calibrator 100 ml , ldh 100 ml , gamma gt 100 ml , micro albumin with calibrator 100 ml , micro protein with calibrator 100 ml , quality controll1 100 ml , quality controll2 100 ml , system multi calibrator 100 ml , crp/rf c(quality control , crp, rf) 100 ml , list of reagents dedicated system pack for dirui cst240 fully automatic biochemistry analyzer(instruction : all parameters should be quotedby bidder) , glucose 100 ml , urea 100 ml , creatinine (enzymatic) 100 ml , uric acid 100 ml , total bilirubin 100 ml , direct bilirubin 100 ml , sgpt 100 ml , sgot 100 ml , lipase 100 ml , amylase 100 ml , alkaline phosphatase 100 ml , total protein 100 ml , albumin 100 ml , calcium 100 ml , phosphorus 100 ml , total cholesterol 100 ml , hdl cholesterol 100 ml , triglyceride 100 ml , microalbumin with calibrator 100 ml , microprotein with calibrator 100 ml , quality controll1 100 ml , quality controll2 100 ml , system multi calibrator 100 ml...

Department of Revenue and Land Reforms - Jharkhand

38843497 bids are invited for 18m suprface pvc board ( q3 ) , 12m suprface pvc board ( q3 ) , 6m suprface pvc board ( q3 ) , 4m suprface pvc board ( q3 ) , 3m suprface pvc board ( q3 ) , 2m suprface pvc board ( q3 ) , 8x12 pvc board ( q3 ) , 8x6 pvc board ( q3 ) , 6x4 pvc board ( q3 ) , 4x4 pvc board ( q3 ) , 8 way mcb box dd ( q3 ) , 12 way mcb box dd ( q3 ) , 6 way mcb box dd ( q3 ) , 4 way mcb box dd ( q3 ) , 36w led tubelight ( q3 ) , 15w bulb ( q3 ) , b / holder ( q3 ) , ceiling rose ( q3 ) , 18w round light panel ( q3 ) , 16a top ( q3 ) , pvc grip ( q3 ) , 1 m / scrup ( q3 ) , 1.5 m / scrup ( q3 ) , 2 m / scrup ( q3 ) , 3 / 4 b / scrup ( q3 ) , 1 black scrup ( q3 ) , 1.5 black scrup ( q3 ) , 0.75mm wire ( q3 ) , 1mm wire ( q3 ) , 1.5 mm wire ( q3 ) , 2.5 mm wires ( q3 ) , 4 mm wire ( q3 ) , 6 mm wire ( q3 ) , 10 mm wires ( q3 ) , big tape ( q3 ) , pipe 3 / 4 1.5mm ( q3 ) , 3 / 4 elbow ( q3 ) , 3 / 4tea ( q3 ) , 3 / 4 circular ( q3 ) , flexible pipes ( q3 ) , 10a 1 way switch ( q3 ) , 10a 2 way switch ( q3 ) , 16a 1 way switch ( q3 ) , 10a socket ( q3 ) , 16a socket ( q3 ) , 25a socket ( q3 ) , 2m regulator ( q3 ) , indicator ( q3 ) , b / plate ( q3 ) , 10a mcb ( q3 ) , 16a mcb ( q3 ) , 25a mcb ( q3 ) , 32a mcb ( q3 ) , 40a dp mcb ( q3 ) , 63a dp mcb ( q3 ) , 100 amp 4 pole mcb ( q3 ) , 100 amp busbar ( q3 ) , 100 amp change over ( q3 ) , 100 amp main switch ( q3 ) , 100w flood light ( q3 ) , 50w flood light ( q3 ) , 70 sqmm x 4 core aluminium armoured cable ( q3 ) , 63a 3 phase rotary ( q3 ) , 4x4 ply 3 / 4 ( q3 ) , aluminum lugs mix size ( q3 ) , mini mcb ( q3 ) , china kanti ( q3 ) , copper palte 2 x 2 ( q3 ) , copper wire 8 no ( q3 ) , panel indicator ( q3 ) , n / bolt ( q3 ) , cable gland ( q3 ) , 120 w led driver ( q3 ) , 4 sqmm 2 core aluminim cable ( q3 ) , v guard model vgmw 300 3 kva stablizer ( q3 ) , v guard model vwr 400 1.5 tonne stablizer ( q3 ) , 2 black scrup ( q3 ) , 32a dp switch ( q3 ) , 100 amp kit kat ( q3 ) , 8m suprface pvc board ( q3 ) total quantity : 5006...

Central Coalfields Limited - Jharkhand

38240777 tender for repairing of wiring 1 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit, with piano type switch, phenolic laminated sheet, suitable size m.s. box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required: group a 2 supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (for light plugs to be used in non residential buildings). 3 supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 4 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator). : 2 + 4 way/ 6 way, double door. 5 supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ‘’c’’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. single pole & neutral. 6 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate as required. 7 providing and fixing following capacity tp&n disconnector fuse switch unit inside the existing panel board with isi marked hrc fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 amp tp&n. 8 supplying and drawing following sizes frls pvc insulated copper conductor, single core cable in existing surface/ recessed steel/ pvc conduit as required. : 2 x 6 sq.mm 9 supplying and drawing following sizes frls pvc insulated copper conductor, single core cable in existing surface/ recessed steel/ pvc conduit as required. : 2 x 4 sq.mm 10 supplying and fixing 3 pin, 5 amps ceiling rose on the existing junction box/ wooden block including connection etc. as required. 11 supplying and fixing brass batten/ angle holder including connection etc. as required. 12 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long with charcoal/ coke and salt as required. 13 total impact of gst for the purpose of ctc ...

Department Of Energy - Jharkhand

38000461 tender for temporay arargonert of suces lighs & rose light on bleeme eie natalled between gondil to lanyar sanliha to desaniyatiker & daraniyatkar in nohat more baschinath at basmath, dunks on the occasion of shrawani 2023 from 207.2023 to 31.08.2003 (61 day)....

Department of School Education - Jharkhand

37470972 bids are invited for led tube light iron primer , iron paint asian , wooden primer , led flood light fitting 100 watt , led flood light fitting 60 watt , garden light fitting , gate light fitting , led tubelight fitting , ceiling fan capacitor , normal tube , pvc tape , gi anchor fastener 8 mm , gi anchor fastener 10 mm , hammer drill bit 6 mm , hammer drill bit 8 mm , hammer drill bit 10 mm , hammer drill bit 12 mm , round sheet 3 inch , 3 core 4 square mm flat cable , 3 core 2.5 square mm flat cable , cable clip , screw 3 inch , pvc fastener gully , half inch pvc pipe , pvc circular box 2 way , pvc circular box 4 way , extension board 5 amp socket 3 no , extension board 5 amp socket 4 no , led bulb 9 watt , led bulb 20 watt , mini jhalar light 10 metre , flexible wire 0.5 mm , extension board 15 amp 1 and 5 amp 5 , ceiling rose , switch fuse unit , mcb 63 amp 4 pole , mcb 40 amp 4 pole , 1 inch upvc pipe , 1 inch upvc elbow , 1 inch upvc socket , 1 inch upvc ball valve , 1 inch upvc gi clamp , 1 inch upvc china clamp , 3 by 4 upvc ball valve , 3 by 4 upvc elbow , 3 by 4 upvc socket , 1 inch tank nipple , 3 by 4 inch tank nipple , 1 inch mta , 1 inch fta , 1 x half brass elbow , 1 inch brass elbow , 1 x 3 by 4 reducer , 1 x half reducer , 1 inch upvc union , 3 by 4 upvc union , solvent m seal , 1 inch upvc tee , 3 by 4 upvc tee , basin waste pipe , basin water tap , basin angle cock , basin connecting pipe half inch , basin connecting pipe 1 inch , water cooler tap , nylan pipe 3 by 4 , section pipe 1 inch , push water tap , half inch nipple , water tap normal , water tap standard , taflon tape , 1 inch screw , half inch screw , diesel filling for genset , half inch upvc elbow , half inch upvc socket , half inch upvc union , half inch mta , half inch fta , half inch brass elbow , upvc pipe , upvc socket , nrv foot ball 1 63 total quantity : 2484...

Jharkhand Police Housing Corporation Limited - Jharkhand

37371859 internal and external electrification work of mandal kara at chas in the district of bokaro ( 1 ) pvc insuleted copper conductor wire of make 2 1.3 point wiring in pvc conduit, with modular type switch: wiring for light point / fan point / exhaust fan point / call bell point with 1.5. sq.mm fr pvc insuleted copper conductor single core cable in recessed pvc conduit, with modular type switch, pheonlic lamineted sheet, suitable size g.i.box etc. 3 1.3.3group c 4 1.7circuit / submain wiring in pvc conduit: wiring for circuit / submain wiring along with earth wire with the following size pvc insuleted copper conductor single core cable in recessed pvc conduit as required 5 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire 6 1.7.114x10.0 sq mm+2x6.0 sq mm earth wire 7 1.24s / f modular type switch / socket : supplying and fixing following modular type switch box / cover including connections but excluding modular plate etc as required 8 1.24.15 / 6 amps, one way switch 9 1.24.45 / 6amps, 3 pin socket outlet 10 1.33s / f ceiling rose: supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box / wooden block including connection etc as required. 11 1.35errection on incandescent light fitting: errection of wall bracket / ceiling fitting, complete with all accessories including connection etc as required. 12 2.9s / f t.p.mcb db: supplying and fixing following way three pole and nutral, sheet, mcb distribution board, 415 volt, in recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 13 2.9.56 way ( 4+18 ) , double door, horizontal type 14 2.11s / f b series. s.p.mcb: supplying and fixing 6 amps to 32 amps rating, 240 volts, b series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting mcb db complite with connections. testing and commisioning etc as required. 15 2.11.16 / 32 amps, single pole, b series 16 2.12s / f c series. s.p.mcb: supplying and fixing 6 amps to 32 amps rating, 240 volts, c series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting mcb db complite with connections. testing and commisioning etc as required. 17 2.12.16 / 32 amps, single pole, c series 18 2.12.1050 / 63 amps, tpn etc...

Department Of Atomic Energy - Jharkhand

37298899 bids are invited for housing colony jaduguda for the year 2024 glazed wall tiles , orissa pattern w c pan , european type w c pan , white vitreous china wash basin , vitreous china wash basin , mirror of superior glass , flushing cistern , low level cistern , pedestal type w c pan , 15 mm bided or jet spray , c p brass shower rose , c p brass angle valve , brass stop cock , close hole wall mixer tap , 75 mmwaste and vent pipes , 100 mm waste and vent pipes , 75 mm plain bend , 100 mm plain bend , 15 mm g i pipes , 20 mm g i pipes , 15mm normal bore g i union , 20 mm normal bore g i union , c p brass extension nipple , p v c waste pipe 32 mm dia , c p brass bib cock , brass bib cock , brass extension nipple , ball valve , renewal of old putty , excavating trenches , surface dressing , transportation of excavated earth , centering and shuttering , centering and shuttering 1 , water proofing treatment , unskilled labour , plumber semi skilled , carpenter semi skilled , sanitary mason semi skilled , civil supervisor semi skilled , synthetic enamel paint , cement primer , chain link , 18 mm thick granite annual civil maintenance and development works in ucil total quantity : 103665...

Ministry Of Micro Small And Meduim Enterprises - Jharkhand

37059756 bids are invited for first aid and stationery items cotton roll , betadine lotion 100 ml , regular bandage handiplast , savlon antiseptic disinfectant liquid 500 ml , cotton bandage 2 inches , leukoplast tape 5 cm x 5m , rose water 120ml , burnol cream 20 gm , moov cream 35 gm , cipladine ointment 20 gm , self sticker paper label a4, 40 labels , correction pen , ohp marker black , permanent marker black , white paint marker , stapler no 10 , stapler 24 6 , plane rule register 240 pages , highlighter colour green , re stick page marker , torch battery r20 , pencil battery aa , brown tape 2 inches , laminated envelope 12 inches x 14 inches , stamp pad blue , stamp pad red , envelope 10 inches x 14 inches , sutli , plastic dustbin 10 ltrs without cover total quantity : 3193...

Jharkhand State Electricity Board - Jharkhand

36990175 housekeeping work in inspection bungalow of srhp sikidiri ( for the period 01.04.2023 to 31.03.2024 ) 1 manpower supplyunskilled labour ( for cleaning and associated work ) 2 semi skilled labour ( for cooking ) 3 unkilled labour ( for cooking ) 4 flowers ( rainy season ) balsam ( hb ) sl 5 rudbekia hb ( pg ) 6 gaillaria ( hb ) sl 7 gaillaria ( hb ) pg 8 rose plant exhibition variety 9 flowers ( winter season ) marigold inca seedings 10 marigold inca polly grawn 11 aster ( hb ) seeding 12 aster ( hb ) pg 13 antirrhinum f1 hybrid si 14 antirrhinum ( hb ) pg 15 dianthus ( hb ) sl 16 dianthus ( hb ) pg 17 cineraria sl ( hb ) 18 cineraria ( hb ) pg 19 pancy ( fihb ) smg pg 20 petunia ( fihb ) pg 21 calendula ( hb ) sl 22 salvia ( hb ) sl 23 salvia hb pg mixed 24 stock hb pg 25 verbena ( hb ) pg 26 dahlia 27 flowers ( summer season ) kochia ( hb ) sl 28 kochia hb pg 29 portulaca hb pg 30 sunflower ( teddybear ) sl 31 cosmos ( hb ) sl 32 cosmos hb pg 33 cellocia hb pg 34 cocks comb ( hb ) sl 35 cocks comb pg 36 zinnia hb pg 37 balsam hb sl 38 rudbekia hb pg 39 gaillaria ( hb ) sl 40 gaillaria hb pg 41 rose plant exhibition variety 42 fertilizers / manure / pesticide / gamla ( pot ) karanj khali 43 badam khali 44 ketchua khad 45 sarso khali 46 bone meal 47 urea 48 phosphate 49 potas 50 d.a.p 51 cow dung manure 52 bioenzeym 53 furadon 54 rogar 250 ml 55 bauistin ( 50gms ) pkt 56 tricel ( 250ml ) 57 gamla earthen pot 10’’...

Navodaya Vidyalaya Samiti - Jharkhand

36628747 bids are invited for boq boq boq air compressor 2 hp double cylinder , bench vice , feeler gauge , spark plug socket wrench , open end spanner set , ring spanner set , socket single hex set , t spanners , extension rod , ratchet handle , impact screw driver imported , allen keys set in mm , allen keys set in inches , adjustable wrench , screw driver plillips , screw driver flat , pliers combination , nose plier , locking plier , circlip pliers , hammer ball pein internal , nylon hammer , hack saw , file flat , center punch , closure , plastic trays , plastic crate , plastic funnel with long tail , oil can , vermer caliper , digital multimeter , hydro meter , acdc digital clamp meter , workshop work table , pneumatic tools , cotton gloves , safety glasses , hydraulic jacks , pullers , aluminium blade , nut volt , plie , ceiling fan clamp , pvc tape , pvc aluminium , 6 square mm cu wire , 4 square mm copper wire , 2.5 square mm cu green wire , 1.5 mm copper wire , 8 x 10 board , 8 x 6 board , 4 x 4 board , 5 amp switch , 5 amp socket , 15 amp switch , 15 amp socket , indicator , ceiling rose , holder , led fittings 18 watt , pvc pipe 1.5 mm , elbow , flexible pipe pvc 3 by 4 , 16 amp mcb sp , 20 amp mcb 3 phase , mcb box 2 way with cover , mcb box 4 way , 63a tpn 1 salator , 63a rcbo with box , ceiling fan , high speed stand fan , 16 swg gi wire total quantity : 378...

Department Of Atomic Energy - Jharkhand

36389537 bids are invited for one year stacking of good earth , stacking of good sludge , spreading of sludge , anti termite treatment , providing plant budded rose , croton challanger variety plant , displaying bougainvillea , maintenance of lawns , antirrhinum dwarf , aster dwarf , calendula double , carnation hybrid , chrysanthemum double , dahlia double , daisy hybrid , gazania hybrid , marigold french hybrid dwarf , marigold inca hybrid , nasturtium , nemesia hybrid , pansy hybrid , petunia hybrid , phlox mix colour hybrid , poppy double , salvia , stock double , verbena hybrid , balsum seedling , celosia argentea and celosia cristata hybrid , cosmos hybrid , gaillardia double , gomphrena , kochia , portulaca hybrid , sunflower dwarf , vinca , zinnia hybrid , impatiens , france beans , brinjal f1 dipansh , watermelon 1 packet , bhindi sujata , bitter gourd , bottle gourd , tomato pusa , capsicum f1 , cherry tomato honey , broccoly , zucchine round , peas azad , ms flat iron tree guard , earthen pot 10 inch size , earthen pot 12 inch size , earthen pot 7 inch size , earthen pot 4 inch size , d a p , urea neem coated , bone meal , mustard oil cake , neem cake powder , bamboo , jute woven yarn sutli , rogor 100ml bottle , super killer 100ml bottle , sarf dust 250 grams , babystin dust 100grms , toprose 500 grams pkt , dhanzime gold 500 ml bottle , dhanzyme , unskilled labour mali nursery and horticulture work in ucil colony jaduguda for total quantity : 2713...

Central Coalfields Limited - Jharkhand

36129588 bids are invited for incoming spout insulator , outgoing spout insulator 11kv 800a , shunt trip coil 110v dc , fixed contact 11kv grade 800a , moving contact 11kv grade 800a , rose contact 11kv grade 800a , spout insulator ryb for busbar 11kv grade 800 amp total quantity : 78...

Water Resources Department - Jharkhand

35827069 sale of scrap vehicles and t and p materials ( list attached ) 1 steel folding chair 2 godrej cane seated armed chair 3 steel folding table 4 wooden almirah 5 single rod room heater 6 duplicating machine 7 vip. mini brief case 8 newar cot 9 steel folding camp cot 10 steel rack 11 mini brief case 12 leveling stand 13 plane table v, ith stand 14 prismatic compass with stand 15 pento graph 28 16 pento graph 36 17 what nut wooden rack . 18 wooden planter 19 wooden office table 20 steel ranging rod 21 plane table with all accessories 22 steel folding table set size 23 air cooler gulmarg with stand 24 godrej cane seated folding chair back 25 wooden cane seated chair 26 half secretariate table sunmica top 27 godrej almirah big size 28 pedestal fan 16 29 wooden chauki 30 theodolite stand 31 dumpy level stand 32 usha cealing fan 56 33 usha cealing fan 48 34 cealing fan 48 35 cealing fan oriental 36 leveling instrument 37 leveling instrument n 9 38 stencil set 39 p ian i inet•.:r 40 theodolite . 41 dumpy level 1 42 water filter plastic 43 portable tent 44 trough compass 45 dining table sunmica top 46 sofa set 47 godrej steel rack 48 palmet 49 amon ia printing machine 50 drafting machine 51 wooden ploting scale 52 wooden bench 53 godrej s type chair 54 godrej revolving chair 55 godrej steel almirah carbon petromax gas 2 torch 4 cell 3 torch 3 cell 4 petromax 5 lock rose all are small size and other models 6 lock rose 21 7 lock click all are small size and other models 8 lock 9 lock rose 10 lock ordinary 11 bucket 11 12 bucket 13 13 bucket small size 14 belcha 15 kudal 16 screw driver 17 engineering chain 18 arrows...

Central Coalfields Limited - Jharkhand

35560410 bids are invited for spares of gec kad ht breaker incoming spout insulator , outgoing spout insulator 11kv 800a , shunt trip coil 110v dc , fixed contact 11kv grade 800a , moving contact 11kv grade 800a , rose contact 11kv grade 800a , spout insulator ryb for busbar 11kv grade 800 amp total quantity : 78...

Military Engineer Services - Jharkhand

35532715 tender for provision medical store office at mh ramgarh surface excavation notexceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. 2 add to ( or deduct from ) above itemno. 1 for every 3cm or part there of above or below 15 cm average depth complete all as specified and directed. 3 excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient forlaying cables / pipes, foundations, laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. 4 returning, filling in including spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by engineer in charge. 5 removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by engineer in charge at a level not exceeding 1.5 m above the starting point complete all as specified. 6 m&l for plain cement concrete 1:4:8 type d 2 ( using 40 mm gradedcrushed stone aggregate ) as in sub base of flooring, foundations, filling & mass concrete for fencing posts, foundation of pole , struts & stay assembly etc complete all as specified and directed. 7 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in foundation including rafts, footings, plinth beams, and mass concreteetc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 8 m& lfor use & wasteof form work to sides of concrete foundation, base of coloumn , rafts, footings, plinth beams, andplinth beamand similar work for rough finished flat surfaces of concrete complete all as specified and directed. 9 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as incolumns, pillars, piers, popst and struts etc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 10 m& lfor use and waste of form work to sidesof columns, pillars, piers, post and struts for rough finished surface of concrete complete all as specified and directed. 11 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 12 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in lintels beam, floor / roof beams, cantilevers, bressummers, , etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 13 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in chajja etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 14 m& lfor use and waste of form work to sidesof soffit ofchajja, chullah hoods, troughs & similaritemsetc includingfor rough finished surface of concrete complete all as specified and directed. 15 m& lfor use and waste of form work to sidesofsoffit ofsuspended slab such as roof slab , floor slab , landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. 16 m& lfor use and waste of form work to sidesandsoffit oflintel beam, floor / roof beams, etcfor rough finished surface of concrete complete all as specified and directed. 17 use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. 18 m&l for brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed. 19 m&l for halfbrick thick brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. 20 m&l for with moorum / red bajri fillingunder the floor not exceeding 100 mm thick spreaded, levelled and rammed including watering complete allas specified & directed . 21 m&l forpre constructionantitermite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 22 m&l forpre constructionantitermite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of verticalsurface ( area of the sub structure in contact with backfill to be measured ) complete allas specified & directed . 23 m&l forpre constructionantitermite treatment for treating the the top surface of filledat the rate of5 litres of emulsion per square metre of surfacecomplete allas specified & directed . 24 m&l forpre constructionantitermite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 25 s & f brass4 screw plate drawer pulls, plate with fixed dished pull; 80 mm to 100mmlong complete all as spcefied and directed 26 s & f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with ms square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by engr in charge . 27 s & f for factory made solid panel pvc door shutter 30mm thick ( style ) consisting of frame made out of ms tube for top and bottom rails. ms framed shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour pvc sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour pvc sheet to be fitted in the ms framed welded / sealed to stiles & rails with suitable pvc sheet beading & joined together with solvent cement complete all asfixing in the frame at site as per specification and drawing including 3 nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed. 28 s&f 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed. 29 s & f 100mm sizebutt hinges medium weight cold rolled mild steel complete all as specified and directed . 30 s&f 150mm extruded aluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 31 s&f 150mmaluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 32 s&f of aluminium mortice lock, vertical type, size 75 mm four levers ( isi marked ) for aluminium doorscomplete all as specified and directed. 33 s&f 65 mm , four lever brasslocks, drawer, grade i of size 65 mmcomplete all as specified and directed. 34 s&ffloor door stopper of aluminium alloy body& tounge, 150 mm , anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 35 s&f brass4 screw drawer plate with fixed dished pull; 80 mm to 100mm longcomplete all as specified and directed. 36 s&ffloor double action spring hinges, brass with phosphor bronze wire spring, bright polished of size 100 mm complete all as specified and directed. 37 m & l for 18 / 19 mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timberframe work complete all as specified and directed. 38 s&f 40mm dia, brass , cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed. 39 s&fbrass handles 150mm size cast type , polished brightcomplete all as specified and directed. 40 m&l for mild steel tmt bars 10mm dia and over grade fe 500, cut to length, bent to shape required, including cranking bending spirally for hooping for column, , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 41 m&l for mild steeltmt bars 08 mm dia and over grade fe 500 , asin stirrups, spacers & binders , cut to length, bent to shape required, including cranking bending spirally for hooping for column, , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 42 m&l for hard core of broken stone or bouldergauge not exceeding 63mm deposited, spread & leveled in layers not exceeding15cm thick, watered and rammed to a true surface etccomplete all as specified& directed. 43 m & l for 75 mm thick plain cement concrete ( 1:3:6 ) mix, type c 1 ( using 20mm graded crushedstone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85 / 25 gradeand sand in the ratio 1:3 including necessary form work , complete all as specified and directed. 44 m & l joint free non skid coloured ceramic tiles 7 to 8 mm thick ( sqaure / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar ( 1:4 ) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed. 45 m & l glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm / 450 mmx 300 mm x7 mm thick, as in dado / skirting etc , set and jointed in neat cement slurry and pointed in colour cement to match the tiles including 10 mm thickrendering in cement plaster in cm ( 1:3 ) , complete all as specified and directed. 46 m&l for vetrifieddark shed coloured ceramicfloor tiles10 mm thick ( square / rectangular ) area of each tileexceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar ( 1:6 ) etc complete all as specified &directed. 47 m&l for vetrifieddark shed ceramic tiles 10 mm thick ( square / rectangular ) area of each tilenot exceeding 0.36 sqmon vertical surface such as skirting / dado etc , set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar ( 1:4 ) etc complete all as specified & directed. 48 m&l for rendering 10 mm thick on brick masonry / concrete surface etc in cm ( 1:6 ) surface finished even & smooth using extra cement complete all as specified and directed. 49 m&l for rendering 15 mm thick on other than fair face brick masonry / concrete surface etc in cm ( 1:4 ) surface finished even & smooth using extra cement complete all as specified and directed. 50 m & l for rendering 5 mm thick in cm 1:4 on concrete surfaces as in ceilingfinished even and faircomplete all as specified and directed. 51 m&l for preparation of newly plastered surfaceof wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 52 m&l for preparation of newly plastered surface of ceilingand applying two coats of oil emulsion distemper over a coat of primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 53 m&l for preparation of newly plastered surfaceof externalwall andapplying two coatacrylicexterior emulsion paint of required shade over and including priming coat of exterior primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 54 s &f powder coated aluminium work for doors, windows, ventilators shutters ( fixed / sliding track two or three track ) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle, c.p. brass / stainless steel screws, all complete all as specified and directed. 55 s&f powder coated aluminiumsliding door shutters ( minimum thickness of powder coating 50 micron ) , aluminium section weighing 0.55 kg / m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long ( 1no. ) , 100mm long hinges type b 21 ( 2nos ) , suitable handle ( 02 nos. ) in each door top rail guide rail etc. complete all as specified and directed. 56 &f powder coated aluminiumwindow and ventilatorshutters ( minimum thickness of powder coating 50 micron ) , fixed typewithout sash baraluminium section weighing 0.55 kg / m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings complete all as specified and directed. 57 s&ffor anodised aluminium grillsfor windows and ventilatoraluminium sections ( weightnot less than 2.25 kg / sqm ) size4mmx4mm, 8mm thick and aperture not exeeding 80 mmx 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tintcomplete all as specified and as directed. 58 s&f 5.5 mm thick sheet glass not exceeding 0.5 sqm ineach pane of superior quality fixed to aluminium frame work with rubber neoprene beadingincluding solar control film 50 micron reflective type sticked to glasspanes as per instructions of manufacturers completeall as specified & directed. 59 s&f 4 mm thick figured glass pin headed type in squares / rectangularnot exceeding 0.5 sqm ineach pane glazing with oil putty or aluminium frame / shutters with rubber neoprene beadingcomplete etc all as specified & directed. 60 s&f for gi water tubing mediumgrade, isi marked, galvanised, 15 mm bore with all fittings, ( such as tee, elbow, socket, union & short pieces ) fixed to walls and ceiling or laid in floors including cutting chasees for brick wallsand making good the surface in cement mortar 1:3 complete all as specified & directed. 61 s&f for gi water tubing mediumgrade, isi marked, galvanised, 25 mm bore with all fittings, ( such as tee, elbow, socket, union & short pieces ) fixed to walls / laid in trenches and ceiling or laid in floors including cutting chasees for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. 62 s&f rotational moulded polythene water storage tank of capacity 1000 ltrs ( cylindrical / vertical with closed type ) , triple layer construction, isi marked, hoisted and fixed in position including 20 mm bore gi nipple and20 mm bore ball / float valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( minimum weight 210 gms ) complete all as specified and directed. 63 s&f 20 mm borebrass ball / float valves high pressure with polythene float & fly nutcomplete all as specified and directed. 64 s&f bib taps long body, cast copper alloy with capstan head or butter fly handle, chromium platedfancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified &directed. 65 s&f fancy type angle stop valve fancy type chromium plated with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15 mm bore complete all as specified &directed. 66 s&f pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered hot or cold with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed. 67 s&f for pvc connection 15 mm dia size with ptmt nuts of length 450 mmcomplete all as specified and directed. 68 s&f 75 mm bore pvc ( swr ) pipes single socketed , in any length with rubber ring joints, laid in trenches , floor or inwall complete all as specified and directed. 69 m&l for 75mm pvc ( swr ) floor trap, plain with grating including jointing with solvent cementwithchromium platedgratingwith or without hole complete all as specified and directed. 70 s & f600mm x 450 mm bevelled edge looking mirror of selected quality glass mounted on 6 mm thick pvc sheet with pvc frame and fixed to wooden plugs with cp brass screw and cup washers complete all as specified and directed. 71 s & f pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, pvc flush pipe 32 mm bore & pvc connection 15 mm bore 450 mm long with ptmt nuts and brackets complete set all as specified anddirected. 72 s & f vitreous china wash basin, any colour, flat back size 550 mm x 400mm including 32mm brass chromium platedwaste coupling , pvc 32 mm bore waste pipe, chromium plated gratingincluding bracket complete all as specified and directed. 73 m&l for pcc 1:2:4 type b 1 ( using 20mm graded crushed stone aggregates ) in kerbs or mud stops, rounded or chamfered on edges water troughs and the like including necessary form workcomplete all as specified and directed. 74 m & l for 15 mm thick screed bed in cement mortar 1:4 mixedwith usingliquid water proofing compoundas per manufacturers instructionsover roof top surface finished even and smooth using extra cement and application of water proofing treatment using app modified roof membrane over existing non accessible / non approachablercc roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed : ( a ) cleaning existing surface properly. ( b ) applying approved bituminousbased primer @ 0.30 litre / sqm manufactured by the same agency as that of app membrane with a density 0.87 0.89 kg per liter at 25 degree centigrade on prepared surface &hot blown grade bitumin85 / 25 @ 1.2 kg / sqm over primer . ( c ) laying not less than 3mm thick app modified water proofing membrane weighing not less than 3.00 kg / sqm reinforced with non woven polyster fiber weight not less than 160gsm / sqm using butane torch by torch application with 10cm side laps and 15cm end lap. physical property of membrane shall be as under : ( i ) membrane weight not less than 3.00 kg / sqm. ( ii ) non woven polyester weight not less than 160 gsm / sqm. ( iii ) softening point of membrane not less than 150degree celsius. ( iv ) joint tensile strength longitudinal not less than 650 kg / sqcm and transverse not less than 450 kg / sq.cm at230 degree celsius. ( v ) tear strength longitudinal not less than 300 n& transverse not less than 250n. ( vi ) elongation of reinforcement not less than 30%. ( vii ) impermeability under water pressure not less than 3 kg / sqcm. ( d ) app membrane shall be laid using butane torch by torch application with minimum 10cm side overlap and 15cm end lap. ( e ) applying two coat of bituminiousbased aluminium paint @ 0.3 kg / sqm over app membrane. ( note:water proofing compound shall be measured and paid seprerately under respective item of boq ) 75 supply only liquid water proofing compound complete all as specified and directed. 76 m&l for 60mm thick factory mademachine pressed pre cast concrete coloured interlocking paver blockof approved shade of any shape and size conforming to is 15658 2006 of m 35 grade laid over &including cleaned dry sand cushion bed 50mm thick over &including 100 mm thick pcc 1:4:8 type d 2 ( using 40mm graded crushed stone aggregate ) assub base, surface finished even and rough over and including 75mm thick hardcore of broken boulder of gauge n exc. 63mm, deposited, spread and levelled, watered and rammed to a true surface, etc complete all as specified and directed. 77 m & l for 100 mm thick concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type d 2 ( using 40 mm gradedcrushed stone aggregate ) complete all as specified & directed. 78 m & l for 150 mm bore ( internal dia ) reinforced concrete drain pipe , class np 3, laid and jointedin trenches complete all as specified & directed. 79 m&l for plain cement concrete 1:3:6 type c 2 ( using 40 mm gradedcrushed stone aggregate ) as in foundations, bed of manhole , filling & mass concrete etc complete all as specified and directed. 80 m&l for plain cement concrete 1:2:4, type b 1 ( using 20 mm graded crushed stone aggregates ) as in surface channels / benching of manhole , drain , laid to shape and slopeand surface finished even & smooth using extra cement complete all as specified and directed 81 s& f 25 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 82 m&l for drilling in existing water pipe, taking new tapping from existing pipe, proper welding to the pipe surface complete all as specified and directed 83 s& f towel ring of ptmt fixed with and including chromium plated brassscrews and wooden / plasticcleats ( minimum weight 90 gms ) complete all as specified and directed 84 s&f vitreous china wash down water closet ( pedestal pattern ) , white ( excluding fixing bolts, flushing cistern and flush pipe ) , fixing seat coverincluding connection to drain ( or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. note : plastic seat cover shall be measured separately as supply only as considered under respective items. 85 supply only plasticwater closet seat cover, black, closed pattern with flat bottom and mild steelchromium plated or aluminium hinging device complete all as specified and directed. 86 s & f health faucets , abs body with 1.0 mtr longeasy flex tube inchrome finish and wall hook complete all as specified and directed. 87 s & f chromium plated toilet paper holder fixed to walls complete all as specified and directed. 88 m&l for point wiring for one light / fan / exhaust fan point / exhaust fan / bell / buzzer pointcontrolled by one way switch with using with frlsh pvc insulated pvc unsheathed electric cable conforming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 1.5 sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid pvc conduit isi marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 sqmm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal boxmade out of 1.6mm thick of suitable size, for mounting fittings / junction boxes including pvc board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing / fixing switches etc., complete all as specified and directed. note: proper colour coding to be adopted. 89 all as per item no. 88 here in before but 5 amp socket outlet on same board. 90 all as per item no. 88 here in before butfor 5 amp switch socketon independent board. 91 m&l for point wiring with frlsh pvc insulated pvc sheathed electric cable confirming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 2.50 sq.mm nominal cross sectional area for phase & neutral& including non metallic rigid pvc conduit isi marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 sq.mm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steelanodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with bakelite hylem sheet 2.80 mm thick complete for one switch socket outlet combination , 15 amps & 5 amp socket point on independent board controlled by one , one way switch complete all as specified and directed. 92 s & f switch piano flush button single pole one way 5 amp, complete all as specified and as directed. 93 s & f socket outlet 2 in 1, 3 pin, 5amp, flush type, universal, complete all as specified. 94 s & f switch socket combination 2 in 1, 3 pin, 5amp and 15 amp flush type, universal, complete all as specified. 95 s & f switch socket combination 2 in 1, 3 pin, 5 amp, flush type, universal, complete all as specified. 96 supply and fix ceiling rose three terminals pvc / polycarbonate, isolated body complete all as specified. 97 s & f lamp holder, pvc / polycarbonate type with back plate having matching colour to holder suitable for angle / batten fittings ( isi marked ) , complete all as specified. 98 s & f bell push type single pole one way 5 amps, complete all as specified. 99 s & f bell electric ding dong ac 230 volts single pole complete all as specified. 100 s & f ceiling rose three terminals pvc / polycarbonate, isolated body complete all as specified. 101 s&f five stepped type electronic fan regulator flush type controlled 230 v, , 120 watt etc complete all as specified and directed. 102 s&f for ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air dilivery 210 cfm with service value 6.00 bee. five star rated with brushless direct current motor ( bldc ) including connecting up with three core flexible copper conductor cable suitable sizefrom ceiling rose to fan terminal with necessary accessoriescomplete all as specified and directed. 103 s & f led light fitting 1 x 20watt , 220 v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by engr in charge.make: havells / bajaj / crompton greaves / phillips. 104 s & f led bulb of capacity 10 watt , lumen out put ( 950 ) lm , length 102 mm dia56 mm , base cap b22 ( isi mark ) complete all as specified and as directed by engr in charge.make: havells / bajaj / crompton greaves / phillips. 105 s & f plastic body exhaust fan of 250 mm sweep with louvers shutter, single phase , 230 v, 50 hz, 1200 rpmac , copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed. 106 s & f sheet metal enclosures for dbs when mcbs to used single pole and neutral ( spn ) double door 240 volts, 8 way with ip 43 ik 09 protection including 200 amp bus bar and neutral link ( isi marked ) , complete all as specified and as directed. 107 s & famp rating 240v, 10 ka c curve miniature circuit breaker ( mcb ) of single poles and neutral and current carrying capacity 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed. make: indoasian or its equivalent make in havells / standard / l&t. 108 s & f240v, 10 ka c curve miniature circuit breaker ( mcb ) of single polesand current carrying capacity 5 to 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed.make: indoasian or its equivalent make in havells / standard / l&t. 109 m & lsub main wiring two single core 6.0 sqmm pvc insulated frlsh multistanderd copper conductor cable and one run of 6.0 sqmmpvc insulated unsheathedfrlsh multi stranded copper conductor cablefor earth wire drawnin & including concealed rigid non metallic pvc conduit medium grade with fittings ( isi marked ) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. note : 2 runs of 6.0 sqmm cable and 1 run of earth wire 6.0 sqmm shall be measured as one unit length. 110 supply, laying , jointing & testing lt under ground cablexlpe insulated, screened , pvc bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty ) with standard aluminium conductor , 1100 voltsgrade of cross sectional area 16 sq mm 2.0 core complete all as specified and directed. 111 material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by engineer in charge.note: for measurement purpose punned thickness shall beconsidered as per clause 19.75 of ssr part i. 112 supplying & laying un reinforced pre cast flat concrete cable protection cover of class lv, type 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the engineer in charge. 113 s & f 25 mm bore gi tube, light grade for cable protection with all necessary fitting, complete with all fittings laid as in floor etc., complete all as specified and as directed. 114 m&l , for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by gi pipe 15 mm bore ( light grade ) and watering pipe 20 mm bore gi pipe ( light grade ) and pcc of chamber and coping shall in 1:3:6 type c 1 using 20 mm graded stone aggregateincluding excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate no 3 of ssr pt i, 2009 with ci cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. note : earth test report should be submitted by the contractor duly tested in presence of engineer in charge 115 m&l for boring ofhole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine with & including provision of 50 mm borelight grade gi pipefor protection of cable complete all as specified and directed by engineer in charge.note : pipes shall be laid minimum 2.00 mtr below / under existing road surfaces / taxi track / apron / floors etc. 116 cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1 / 2 round or ¾ section ) in cement concrete 1:2:4 type b 1 smooth finished, and reforming benching as required in 150mm internal diapipe complete all as specified and as directed....

Indian Army - Jharkhand

34994483 bids are invited for sup of br and em items at suratgarh paint , red oxide , glass pane , gi pipe , tee , gate valve , bib cock , float valve , pillar cock , pvc connector , looking mirror , stop cock , waste pipe , elbow , socket , nipple , cable , led , angle holder , ceiling fan , ceiling rose , switch socket , mcb , tube light , regulator , swithch , security light total quantity : 821...

Military Engineer Services - Jharkhand

34972110 provision of medical store office at mh ramgarh 1 surface excavation notexceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. 2 add to (or deduct from) above itemno. 1 for every 3cm or part there of above or below 15 cm average depth complete all as specified and directed. 3 excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. 4 returning, filling in including spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by engineer in charge. 5 removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by engineer in charge at a level not exceeding 1.5 m above the starting point complete all as specified. 6 m&l for plain cement concrete 1:4:8 type d 2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. 7 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in foundation including rafts, footings,plinth beams, and mass concreteetc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 8 m& lfor use & wasteof form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, andplinth beamand similar work for rough finished flat surfaces of concrete complete all as specified and directed. 9 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as incolumns,pillars,piers,popst and struts etc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 10 m& lfor use and waste of form work to sidesof columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed. 11 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 12 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in lintels beam, floor/roof beams, cantilevers, bressummers, ,etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 13 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in chajja etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 14 m& lfor use and waste of form work to sidesof soffit ofchajja,chullah hoods,troughs & similaritemsetc includingfor rough finished surface of concrete complete all as specified and directed. 15 m& lfor use and waste of form work to sidesofsoffit ofsuspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. 16 m& lfor use and waste of form work to sidesandsoffit oflintel beam,floor/roof beams, etcfor rough finished surface of concrete complete all as specified and directed. 17 use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of rcc/ pcc bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. 18 m&l for brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed. 19 m&l for halfbrick thick brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. 20 m&l for with moorum/ red bajri fillingunder the floor not exceeding 100 mm thick spreaded, levelled and rammed including watering complete allas specified & directed . 21 m&l forpre constructionantitermite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 22 m&l forpre constructionantitermite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of verticalsurface (area of the sub structure in contact with backfill to be measured) complete allas specified & directed . 23 m&l forpre constructionantitermite treatment for treating the the top surface of filledat the rate of5 litres of emulsion per square metre of surfacecomplete allas specified & directed . 24 m&l forpre constructionantitermite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 25 s & f brass4 screw plate drawer pulls, plate with fixed dished pull; 80 mm to 100mmlong complete all as spcefied and directed 26 s & f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with ms square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by engr in charge . 27 s & f for factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tube for top and bottom rails. ms framed shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour pvc sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour pvc sheet to be fitted in the ms framed welded/sealed to stiles & rails with suitable pvc sheet beading & joined together with solvent cement complete all asfixing in the frame at site as per specification and drawing including 3 nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed. 28 s&f 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed. 29 s & f 100mm sizebutt hinges medium weight cold rolled mild steel complete all as specified and directed . 30 s&f 150mm extruded aluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 31 s&f 150mmaluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 32 s&f of aluminium mortice lock,vertical type, size 75 mm four levers (isi marked) for aluminium doorscomplete all as specified and directed. 33 s&f 65 mm ,four lever brasslocks, drawer,grade i of size 65 mmcomplete all as specified and directed. 34 s&ffloor door stopper of aluminium alloy body& tounge,150 mm ,anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 35 s&f brass4 screw drawer plate with fixed dished pull; 80 mm to 100mm longcomplete all as specified and directed. 36 s&ffloor double action spring hinges,brass with phosphor bronze wire spring, bright polished of size 100 mm complete all as specified and directed. 37 m & l for 18/19 mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timberframe work complete all as specified and directed. 38 s&f 40mm dia,brass ,cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed. 39 s&fbrass handles 150mm size cast type ,polished brightcomplete all as specified and directed. 40 m&l for mild steel tmt bars 10mm dia and over grade fe 500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 41 m&l for mild steeltmt bars 08 mm dia and over grade fe 500 , asin stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 42 m&l for hard core of broken stone or bouldergauge not exceeding 63mm deposited, spread & leveled in layers not exceeding15cm thick, watered and rammed to a true surface etccomplete all as specified& directed. 43 m & l for 75 mm thick plain cement concrete (1:3:6) mix, type c 1 (using 20mm graded crushedstone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 gradeand sand in the ratio 1:3 including necessary form work , complete all as specified and directed. 44 m & l joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces,complete all as specified and directed. 45 m & l glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm/450 mmx 300 mm x7 mm thick,as in dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles including 10 mm thickrendering in cement plaster in cm (1:3), complete all as specified and directed. 46 m&l for vetrifieddark shed coloured ceramicfloor tiles10 mm thick (square/rectangular) area of each tileexceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:6) etc complete all as specified &directed. 47 m&l for vetrifieddark shed ceramic tiles 10 mm thick (square/rectangular) area of each tilenot exceeding 0.36 sqmon vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed. 48 m&l for rendering 10 mm thick on brick masonry/concrete surface etc in cm (1:6) surface finished even & smooth using extra cement complete all as specified and directed. 49 m&l for rendering 15 mm thick on other than fair face brick masonry/concrete surface etc in cm (1:4) surface finished even & smooth using extra cement complete all as specified and directed. 50 m & l for rendering 5 mm thick in cm 1:4 on concrete surfaces as in ceilingfinished even and faircomplete all as specified and directed. 51 m&l for preparation of newly plastered surfaceof wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specifiedand directed. 52 m&l for preparation of newly plastered surface of ceilingand applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specifiedand directed. 53 m&l for preparation of newly plastered surfaceof externalwall andapplying two coatacrylicexterior emulsion paint of required shade over and including priming coat of exterior primer and a layer of putty (not less than 1.5 mm thick ) complete all as specifiedand directed. 54 s &f powder coated aluminium work for doors, windows, ventilators shutters(fixed/sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle,c.p. brass/ stainless steel screws, all complete all as specified and directed. 55 s&f powder coated aluminiumsliding door shutters (minimum thickness of powder coating 50 micron) , aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long (1no.),100mm long hinges type b 21 (2nos), suitable handle(02 nos.) in each door top rail guide rail etc. complete all as specified and directed. 56 &f powder coated aluminiumwindow and ventilatorshutters (minimum thickness of powder coating 50 micron) ,fixed typewithout sash baraluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings complete all as specified and directed. 57 s&ffor anodised aluminium grillsfor windows and ventilatoraluminium sections (weightnot less than 2.25 kg/sqm) size4mmx4mm, 8mm thick and aperture not exeeding 80 mmx 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tintcomplete all as specified and as directed. 58 s&f 5.5 mm thick sheet glass not exceeding 0.5 sqm ineach pane of superior quality fixed to aluminium frame work with rubber neoprene beadingincluding solar control film 50 micron reflective type sticked to glasspanes as per instructions of manufacturers completeall as specified & directed. 59 s&f 4 mm thick figured glass pin headed type in squares/ rectangularnot exceeding 0.5 sqm ineach pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beadingcomplete etc all as specified & directed. 60 s&f for gi water tubing mediumgrade, isi marked,galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick wallsand making good the surface in cement mortar 1:3 complete all as specified & directed. 61 s&f for gi water tubing mediumgrade, isi marked,galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls /laid in trenches and ceiling or laid in floors including cutting chasees for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. 62 s&f rotational moulded polythene water storage tank of capacity 1000 ltrs (cylindrical/vertical with closed type), triple layer construction, isi marked, hoisted and fixed in position including 20 mm bore gi nipple and20 mm bore ball/ float valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms)complete all as specified and directed. 63 s&f 20 mm borebrass ball/ float valves high pressure with polythene float & fly nutcomplete all as specified and directed. 64 s&f bib taps long body, cast copper alloy with capstan head or butter fly handle, chromium platedfancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified &directed. 65 s&f fancy type angle stop valve fancy type chromium plated with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15 mm bore complete all as specified &directed. 66 s&f pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered hot or cold with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed. 67 s&f for pvc connection 15 mm dia size with ptmt nuts of length 450 mmcomplete all as specified and directed. 68 s&f 75 mm bore pvc(swr) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or inwall complete all as specified and directed. 69 m&l for 75mm pvc (swr) floor trap, plain with grating including jointing with solvent cementwithchromium platedgratingwith or without hole complete all as specified and directed. 70 s & f600mm x 450 mm bevelled edge looking mirror of selected quality glass mounted on 6 mm thick pvc sheet with pvc frame and fixed to wooden plugs with cp brass screw and cup washers complete all as specified and directed. 71 s & f pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, pvc flush pipe 32 mm bore & pvc connection 15 mm bore 450 mm long with ptmt nuts and brackets complete set all as specified anddirected. 72 s & f vitreous china wash basin, any colour, flat back size 550 mm x 400mm including 32mm brass chromium platedwaste coupling ,pvc 32 mm bore waste pipe, chromium plated gratingincluding bracket complete all as specified and directed. 73 m&l for pcc 1:2:4 type b 1 (using 20mm graded crushed stone aggregates) in kerbs or mud stops, rounded or chamfered on edges water troughs and the like including necessary form workcomplete all as specified and directed. 74 m & l for 15 mm thick screed bed in cement mortar 1:4 mixedwith usingliquid water proofing compoundas per manufacturers instructionsover roof top surface finished even and smooth using extra cement and application of water proofing treatment using app modified roof membrane over existing non accessible/non approachablercc roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed : (a) cleaning existing surface properly.(b) applying approved bituminousbased primer @ 0.30 litre / sqm manufactured by the same agency as that of app membrane with a density 0.87 0.89 kg per liter at 25 degree centigrade on prepared surface &hot blown grade bitumin85/25 @ 1.2 kg/sqm over primer .(c) laying not less than 3mm thick app modified water proofing membrane weighing not less than 3.00 kg/sqm reinforced with non woven polyster fiber weight not less than 160gsm/sqm using butane torch by torch application with 10cm side laps and 15cm end lap. physical property of membrane shall be as under : (i) membrane weight not less than 3.00 kg/sqm. (ii)non woven polyester weight not less than 160 gsm/sqm.(iii)softening point of membrane not less than 150degree celsius. (iv)joint tensile strength longitudinal not less than 650 kg / sqcm and transverse not less than 450 kg /sq.cm at230 degree celsius. (v) tear strength longitudinal not less than 300 n& transverse not less than 250n.(vi)elongation of reinforcement not less than 30%.(vii) impermeability under water pressure not less than 3 kg/sqcm.(d) app membrane shall be laid using butane torch by torch application with minimum 10cm side overlap and 15cm end lap. (e) applying two coat of bituminiousbased aluminium paint @ 0.3 kg /sqm over app membrane.(note:water proofing compound shall be measured and paid seprerately under respective item of boq) 75 supply only liquid water proofing compound complete all as specified and directed. 76 m&l for 60mm thick factory mademachine pressed pre cast concrete coloured interlocking paver blockof approved shade of any shape and size conforming to is 15658 2006 of m 35 grade laid over &including cleaned dry sand cushion bed 50mm thick over &including 100 mm thick pcc 1:4:8 type d 2 (using 40mm graded crushed stone aggregate) assub base, surface finished even and rough over and including 75mm thick hardcore of broken boulder of gauge n exc. 63mm, deposited, spread and levelled, watered and rammed to a true surface, etc complete all as specified and directed. 77 m & l for 100 mm thick concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type d 2 (using 40 mm gradedcrushed stone aggregate ) complete all as specified & directed. 78 m & l for 150 mm bore (internal dia )reinforced concrete drain pipe ,class np 3, laid and jointedin trenches complete all as specified & directed. 79 m&l for plain cement concrete 1:3:6 type c 2(using 40 mm gradedcrushed stone aggregate) as in foundations, bed of manhole ,filling & mass concrete etc complete all as specified and directed. 80 m&l for plain cement concrete 1:2:4, type b 1 (using 20 mm graded crushed stone aggregates) as in surface channels /benching of manhole ,drain ,laid to shape and slopeand surface finished even & smooth using extra cement complete all as specified and directed 81 s& f 25 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 82 m&l for drilling in existing water pipe, taking new tapping from existing pipe,proper welding to the pipe surface complete all as specified and directed 83 s& f towel ring of ptmt fixed with and including chromium plated brassscrews and wooden/plasticcleats (minimum weight 90 gms) complete all as specified and directed 84 s&f vitreous china wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat coverincluding connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. note : plastic seat cover shall be measured separately as supply only as considered under respective items. 85 supply only plasticwater closet seat cover,black,closed pattern with flat bottom and mild steelchromium plated or aluminium hinging device complete all as specified and directed. 86 s & f health faucets ,abs body with 1.0 mtr longeasy flex tube inchrome finish and wall hook complete all as specified and directed. 87 s & f chromium plated toilet paper holder fixed to walls complete all as specified and directed. 88 m&l for point wiring for one light/fan/exhaust fan point /exhaust fan/ bell /buzzer pointcontrolled by one way switch with using with frlsh pvc insulated pvc unsheathed electric cable conforming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 1.5 sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid pvc conduit isi marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 sqmm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal boxmade out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including wooden board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing/fixing switches etc., complete all as specified and directed. note: proper colour coding to be adopted. 89 all as per item no. 88 here in before but 5 amp socket outlet on same board. 90 all as per item no. 88 here in before butfor 5 amp switch socketon independent board. 91 m&l for point wiring with frlsh pvc insulated pvc sheathed electric cable confirming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 2.50 sq.mm nominal cross sectional area for phase & neutral& including non metallic rigid pvc conduit isi marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 sq.mm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steelanodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with bakelite hylem sheet 2.80 mm thick complete for one six pin switch socket outlet combination ,15 amps & 5 amp socket point on independent board controlled by one ,one way switch complete all as specified and directed. 92 s & f switch piano flush button single pole one way 5 amp, complete all as specified and as directed. 93 s & f socket outlet 2 in 1, 3 pin, 5amp, flush type, universal, complete all as specified. 94 s & f switch socket combination 2 in 1, 3 pin, 5amp and 15 amp flush type, universal, complete all as specified. 95 s & f switch socket combination 2 in 1, 3 pin, 5 amp, flush type, universal, complete all as specified. 96 supply and fix ceiling rose three terminals pvc/ polycarbonate, isolated body complete all as specified. 97 s & f lamp holder, pvc/polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (isi marked), complete all as specified. 98 s & f bell push type single pole one way 5 amps, complete all as specified. 99 s & f bell electric ding dong ac 230 volts single pole complete all as specified. 100 s & f ceiling rose three terminals pvc/ polycarbonate, isolated body complete all as specified. 101 s&f five stepped type electronic fan regulator flush type controlled 230 v, , 120 watt etc complete all as specified and directed. 102 s&f for ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air dilivery 210 cfm with service value 6.00 bee. five star rated with brushless direct current motor (bldc) including connecting up with three core flexible copper conductor cable suitable sizefrom ceiling rose to fan terminal with necessary accessoriescomplete all as specified and directed. 103 s & f led light fitting 1 x 20watt , 220 v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by engr in charge.make: havells/bajaj/crompton greaves/phillips. 104 s & f led bulb of capacity 10 watt , lumen out put (950)lm ,length 102 mm dia56 mm , base cap b22 (isi mark) complete all as specified and as directed by engr in charge.make: havells/bajaj/crompton greaves/phillips. 105 s & f plastic body exhaust fan of 250 mm sweep with louvers shutter,single phase ,230 v,50 hz,1200 rpmac ,copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed. 106 s & f sheet metal enclosures for dbs when mcbs to used single pole and neutral (spn) double door 240 volts, 8 way with ip 43 ik 09 protection including 200 amp bus bar and neutral link (isi marked), complete all as specified and as directed. 107 s & famp rating 240v, 10 ka c curve miniature circuit breaker (mcb) of single poles and neutral and current carrying capacity 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed. make: indoasian or its equivalent make in havells/standard/l&t. 108 s & f240v, 10 ka c curve miniature circuit breaker (mcb) of single polesand current carrying capacity 5 to 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed.make: indoasian or its equivalent make in havells/standard/l&t. 109 m & lsub main wiring two single core 6.0 sqmm pvc insulated frlsh multistanderd copper conductor cable and one run of 6.0 sqmmpvc insulated unsheathedfrlsh multi stranded copper conductor cablefor earth wire drawnin & including concealed rigid non metallic pvc conduit medium grade with fittings (isi marked) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. note : 2 runs of 6.0 sqmm cable and 1 run of earth wire 6.0 sqmm shall be measured as one unit length. 110 supply, laying , jointing & testing lt under ground cablexlpe insulated, screened ,pvc bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 voltsgrade of cross sectional area 16 sq mm 2.0 core complete all as specified and directed. 111 material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by engineer in charge.note: for measurement purpose punned thickness shall beconsidered as per clause 19.75 of ssr part i. 112 supplying & laying un reinforced pre cast flat concrete cable protection cover of class lv, type 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the engineer in charge. 113 s & f 25 mm bore gi tube, light grade for cable protection with all necessary fitting, complete with all fittings laid as in floor etc., complete all as specified and as directed. 114 m&l ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by gi pipe 15 mm bore (light grade) and watering pipe 20 mm bore gi pipe (light grade) and pcc of chamber and coping shall in 1:3:6 type c 1 using 20 mm graded stone aggregateincluding excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate no 3 of ssr pt i, 2009 with ci cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. note : earth test result should not less than one ohm. 115 m&l for boring ofhole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine with & including provision of 50 mm borelight grade gi pipefor protection of cable complete all as specified and directed by engineer in charge.note : pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/taxi track / apron /floors etc. 116 cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type b 1 smooth finished, and reforming benching as required in 150mm internal diapipe complete all as specified and as directed. ...

Hindustan Copper Limited - Jharkhand

34664812 procurement of electrical general items for mbr electrical procurement of electrical general items for mbr electrical , 5/8 brass angle holder , electronic fan regulator for 56/48 sweep. , twin twisted pvc insulated flexible wire copp er 250/440v grade 24/0.020mm , single core pvc insulated cable copper conductor1.5sq.mm , capping and casing size 3/4 , capping and casing size 1 , teak wood board ( 7 x 5x 2.5) with white sunmica sheet (7 x 5 ) complete with require nos of wooden screw , teak wood board ( 10 x 8x 2.5) with white sunmica sheet (10 x 8 ) complete with require nos of wooden screw , white sunmica sheet(1000 mm x 1000 mm x 3 mm) , 22 watt led 4ft. tube light fitting complete with led tube light, driver and other required accessories , 1.1 kv/690v gr. pvc insulated flexible copper wire, size :0.75mm2, single core multi strand , 80watt led street light complete fitting along with driver, led lights etc. in die cast aluminium housing. details as per annexure. , piano type switch, rating: 5 amp, 230v. the supply includes suitable cover. , piano type socket, rating: 5 amp, 230v. the supply includes suitable cover. , led bulb, rating 12 w, suitable for230v ac supply. , 1.1 kv/690v grade, flat aluminium conductor, size: 2 core, 6sqmm. , brass machine counter head screw. size 1inch. , wooden counter head screw. size 1inch. , wooden counter head screw. size 1.5 inch. , pvc junction box for house wiring, 4inch× 4inch for conceal wiring , pvc ceiling rose , pvc saddle china clip (16mm, single nail) , pvc gulley , 2 inch caping casing , ss nail, 1 inch...

Central Mine Planning And Design Institute Limited - Jharkhand

34590139 supply of materials and installation of power supply arrangement through fresh electrical wiring 1 wiring for circuit /submain wiring along with earth wire with the following size of fr pvc insulated copper conductor ,single core cable in surface/recessed medium class pvc conduit as required. 2 2x10 sq. mm+1x6 sq. mm earth wire 3 2x16 sq. mm+1x6 sq. mm earth wire 4 2x6 sq. mm+1x6 sq. mm earth wire 5 2x2.5 sq. mm+1x2.5 sq. mm earth wire 6 supplying and fixingdp sheet steel enclosure on surface/recess along with 25/32 amps 240 volts c curve dp mcb complete with connections,testing and commossioning etc.as required. 7 supplying and fixing following way,single pole and neutral,sheet steel,mcb distribution board,240 volts,on surface/recessed,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar, interconnections, powder painted including earthing etc.as required.(but without mcb/rccb/isoltor) 8 2+4 way,single door 9 2+6 way,single door 10 2+10 way,single door 11 supplying and fixing 5 amps to 32 amps rating,240/415 volts,c, miniature circuit breaker suitable for inductive load of following poles of existing mcb db complete with connections,testing and commining etc.as required. 12 double pole,32 amp 13 double pole,25 amp 14 single pole,20 amp 15 single pole,16 amp 16 single pole,10 amp 17 wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface/recessed medium class pvc conduit ,with piano type switch,phenolic laminated sheet ,suitable size m.s. box and earthing the point with 1.5 sq. mm fr pvc insulated copper conductor single core cable etc as required. 18 group b 19 supply and fixing following piano type switch/soccket on the existing switch box/cover including connections etc as required. 20 5/6 amps switch 21 3 pin 5/6 amp socket outlet 22 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc as required. 23 supplying and fixing call bell/buzzer suitable forsingle phase, 230 volts, complete as required.required. 24 20 mm junction box,one way/two way 25 supplying and fixing brass batten/ angle holder including connection etc.as required. 26 supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. 27 wiring for light/power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/recessed medium class pvc conduit along with 1 no 4 sq.mm fr pvc insulated copper conductor single core cable for loop earthing as required. 28 supply and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection,painting etc. as required. 29 supply and fixing metal box of 150 mm x 75 mm x 60 mm deep(nominal size of phenilic laminated sheet cover in front including providing and fixing 3 pin 5 / 6amps socketoutlet and 5 / 6 amps piano type switch, connection, painting etc. as required. 30 supply and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 31 100mmx100mmx60mm deep 32 eartthing with g.i. earth plate 600 mm x600 mm x 6 mm thick including accessories and providing masonry encloused with cover plate havinglocking arrengement and watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required. 33 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required. 34 providing and fixing 63a,16ka,three pole mccb in existing cubical pannel including drilling holes in cubical panel,making connections, etc as requrired. 35 enclosure for 63a mccb of sheet steel,dust protected,dully powder painted. 36 supply & fixing inclosure for 40 amp and 25 ampdp, mcb as an out going distribution boardof sheet steel, dust protected,dully powder painted. 37 providing and fixing 40a,16ka,dp mcb in existing cubical panel including ,making connections, etc as required 38 light shed 39 providing and laying earth connetion from earth electrode with6 swg dia g.i. wire in 25 mm dia pvc pipe of medium class from eatrth electrode including connection with g.i thimble, refilling as required. 40 miscellaneous including cleaning of rubbish, mending of wall, floor damage etc. 41 total impact of gst for the purpose of ctc ...

Urban Development Department - Jharkhand

34512363 construction of road and drain ( 1 ) road from chhatabad bhuiya dhowra to chattabad main road via shiv mandir and rose medical ( 2 ) drain from ramavtar yadav house ..... via palji house in ward no. 02 under dmc, dhanbad...

Central Coalfields Limited - Jharkhand

34155555 bids are invited for non modular elecrical switches and accessories flush type is 3854 (q3) , modular electrical switches and accessories (q3) , ceiling rose is 371 (q3) , bayonet lamp holders asper is 1258 (q2)mse total quantity : 300...

Central Coalfields Limited - Jharkhand

34055453 bids are invited for tripping coil , fixed contact , moving contact , rose contact , current transformer , potential transformer total quantity : 50...

Department Of Atomic Energy - Jharkhand

33975299 bids are invited for construction of community centre atturamdih township 1 earth work in excavation by mechanical means hydraulic excavator or manual means over areas exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan including disposal of excavated earth lead upto 50m and lift upto 1.5m disposed earth to be levelled and neatly dressed complete as per direction of eic. 2 excavating trenches of required width for pipes cables etc including excavation for sockets depth upto 1.5 m including getting out the excavated materials returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed within a lead of 50m as per direction of eic. pipes cables etc. not exceeding 80 mm dia. 3 filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 4 supplying and filling in plinth with foundation plinth wall sand under floors including watering ramming consolidating and dressing complete as per direction of eic. 5 surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m all kind of soil. 6 diluting and injecting chemical emulsion for postconstructional antitermite treatment excluding the cost of chemical emulsion treatment of soil under existing floors using chemical emulsion the existing floor. 7 treatment of existing masonry using chemical emulsion at the rate one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1 isto 2 1 cement isto 2 coarse sand to the full depth of the hole with chlorpyriphos or lindane ec 20 per cent with 1 percent concentration 8 providing and laying damp proof course 40mm thick with cement concrete 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 12.5 mm nominal size. 9 extra for providing and mixing water proofing material in cement concrete work at the rate 1 kg per 50kg of cement. 10 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size including cost of cement reinforced cement as per direction of eic. 11 rcc in retaining walls roofs return walls walls any thickness including attached pilasters columns piers abutments pillars posts struts buttresses string or lacing courses parapets coping bed blocks anchor blocks plain window sills fillets upto floor five level excluding the cost of centering shuttering and finishing 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size. 12 centering and shuttering including strutting propping etc. and removal of form for lintels beams plinth beams girders bressumers and cantilevers as per direction of eic. 13 reinforcement for rcc work including straightening cutting bending placing in position and binding all complete cold twisted bars 14 brick work with fps bricks of class designation 75 in foundation and plinth in cement mortar 1 isto 6 1 cement isto 6 coarse sand including mixing of mortar laying of bricks raking joints curing etc complete including cost of cement specification and direction of eic. 15 brick work with fps bricks of class designation 75 in super structure in cement mortar 1 isto 6 1 cement isto 6 coarse sand including mixing of mortar laying of bricks raking joints curing etc complete including cost of cement specification and direction of eic. 16 half brick masonry with fps bricks of class designation 75 in superstructure above plinth level upto floor v level. cement mirtar 1 isto 4 1 cement isto 4 coarse sand complete as per the direction of eic. 17 providing and fixing isi marked flush door shutters conforming to is2202 part i decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 30mm thick including isi marked stainless steel butt hinges with necessary screws complete as per the direction of eic. 18 providing and fixing oxidised ms sliding door bolts with nuts and screws etc. complete 300 into 16mm 19 providing and fixing oxidised ms tower bolts black finish barrel type with necessary screws etc. complete 20 providing and fixing oxidised ms handles with necessary screws etc. complete 125mm 21 providing and fixing factory made steel glazed doors windows and ventilators side or top or centre hung with beading and all members of standard rolled steel sections joints mitred and flash butt welded and sash bars tenoned and riveted with 15 into 3mm lugs 10cm long embedded in cement concrete blocks 15 into 10 into 10cm of 1isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20mm nominal size or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including providing and fixing of hinges pivots float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design complete as per the direction of eic. 22 providing and fixing tiron frames for doors windows and ventilators of mild steel tee ections joints mitred and welded with 15 into 3 mm lugs 10cm long embedded in cement concrete blocks 15 into 10 into 10 cm of 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer complete as per the direction of eic. 23 providing and fixing ms fan clamp type i or ii of 16mm dia ms bar bent to shape with hooked ends in rcc slabs beams during laying including painting the exposed portion of loop all as per standard design complete complete as per the direction of eic. 24 cement concrete flooring 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete complete as per the direction of eic. 40mm thick with 20 mm nominal size stone aggregate. 25 providing and laying ceramic glazed floor tiles 300 into 300 mm thickness to be specified by the manufacturer of 1st quality conforming to is 15622 of approved make in colours such as white ivory grey fume red brown laid on 20mm thick cement mortar 1 isto 4 1 cement isto 4 coarse sand including pointing the joints with white cement and matching prgment etc. complete as per the direction of eic. 26 providing and fixing 1st quality ceramic glazed wall tiles conforming to is 15622 of approved make in all colours shades except burgundy bottle green black of any size as approved by eic in skirting, risers of steps and dados over 6 mm thick bed of cement mortar 1 isto 3 1 cement isto 3 coarse sand and jointing with grey cement slurry at the rate 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 27 providing and fixing on wall face pvc rain water pipes or toilet pipe including ms holder bat clamps wooden pegs etc with accessories like ci grating plain bend head shoes etc including filling joints with spun yarn soaked in neat cement slurry and cement mortar 1 isto 2 1 cement isto 2 fine sand including a coat of primer cost of all materials labour tools and tackles etc complete complete as per the direction of eic. upvc pipes working pressure 4 kgpersqm single socketed pipe 110 mm dia 28 12mm cement plaster of mix 1 isto 4 1 cement isto 4 fine sand complete as per the direction of eic. 29 15mm cement plaster on the rough side of single or half brick wall of mix 1 isto 6 1 cement isto 6 fine sand complete as per the direction of eic. 30 6mm cement plaster 1 isto 3 1 cement isto 3 fine sand finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of rcc slabs and beams complete as per the direction of eic. 31 supplying and applying two 2 coats of white wash over old work at various elevations including preparation of surfaces cleaning etc. complete with all materials labour tools and tackle etc scaffolding work as per specifications and directions of eic. composition water at the rate 5 litres per kg of lime for making cream. fevicol ddl at the rate 4 gm per litre of lime cream. robin blue at the rate 2gm. per kg lime. 32 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work two or more coats over and including priming coat with cement primer. 33 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade approved brand and manufuacturer and ist quality 10 yrs like asian berger nerolac ici dulux old work one or more coats applied at the rate 0.83 ltr per10 sqm. 34 applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work second coat 35 painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work. 36 providing groove of uniform size in plastered surface as per approved pattern using wooden battens bnailed to the under layer including of wooden battens repairs to the edges of the plaster panel and finishing the groove complete as per specifications and direction of eic including all materials labour tools and tackles etc complete. 12mm into 12mm 37 demolishing cement concrete manually or by mechanical means including disposal of material within 50 metres lead as per direction of eic. 1 isto 3 isto 6 or richer mix 38 demolishing brick work in cement mortar including tacking of serviceable material and disposal of unserviceable material within 50 metres lead including all materials labour tools and tackles etc complete 39 making plinth protection 50mm thick of cement concrete 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size over 75 mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 40 providing and fixing water closet squatting pan indian type wc pan with 100mm sand cast iron p or s trap 10 litre low level white pvc flushing cistern with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern wc pan of size 580 into 440mm with integral type foot rests. 41 providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors ci trap and bend 100 mm inlet and 75 mm outlet sand cast iron sands as per is1729 42 providing and fixing 600 into 450 mm beveled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with c p brass screws and washers complete 43 providing & fixing 600 into 120 into 5mm glass shelf with edges round of supported on anodised aluminium angle frame with c p brass brackets and guard rail complete fixed with 40mm long screws rawl plugs etc. complete 44 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm long towel rail with total legth of 645mm width 78mm and effective height of 88mm weighing not less than 190 gms. 45 providing and fixing 2mm thick plaster of paris 46 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 15mm dia nominal bore 47 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 20mm dia nominal bore 48 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 25mm dia nominal bore 49 providing and fixing gun metal gate valve with ci wheel of approved quality screwed end 25 mm nominal bore 50 providing and fixing cp brass shower rose with 15 or 20mm inlet 100 mm diameter make emco 51 providing and fixing c p brass bib cock of approved quality make emco 15mm nominal bore 52 constructing masonry chamber 60 into 60 into 75cm inside with 75 class designation brick work in cement mortar 1 isto 4 1 cement isto 4 coarse sand for sluice valve with ci surface box 100mm top diameter 160 mm bottom diameter and 180mm deep inside with chained lid and rcc top slab 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size necessary excavation foundation concrete 1 isto 5 isto 10 1 cement isto 5 fine sand isto 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1 isto 3 1 cement isto 3 coarse sand 12mm thick finished with a floating coat of neat cement complete as per standard design with fps bricks complete as per the direction of eic. 53 providing & fixing c p brass stop cock concealed of standard design and of approved make conforming to is 8931.15mm nominal bore. 54 making soak pit 2.5 m diameter 3.0 metre deep with 45 into 45cm dry brick honey comb shaft with bricks of class designation 75 and sw drain pipe 100mm diameter 1.8m long complete as per standard design with fps bricks 55 grading roof for water proofing treatment with cement concrete 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20mm nominal size 56 providing and placing on terrace at all floor levels polyethylene water storage tank isi 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflor pipes but without fittings and the base support for tank.make sintex 57 providing and fixing wash basin with ci brackets 15mm cp brass pillar taps 32mm cp brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever required white vitreous china wash basin size 630 into 450 mm with a pair of 15mm c. p brass pillar taps complete as per the direction of eic. 58 wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit as required 2 into 6 sqmm plus 1 into 6 sq mm earth wire 59 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc.as required 60 wiring for light or power plug with 2 into 4 sqmm frls pvc insulated copper conductor single core cable in surface ot recessed medium class pvc conduit alongwith 1 no. 4 sqmm frls pvc insulated copper conductor single core cable for loop earthing as required 61 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required 62 3 pin 5or6 a socket outlet 63 6 pin 15or16 a socket outlet 64 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 65 supplying and fixing following size or modules gi box alongwith modular base and cover plate for modular switches in recess etc. 1 or 2 module 75 mm into 75 mm 66 4 module 125 mm into 75 mm 67 8 module 125 mm into 125 mm 68 supplying and fixing 3 pin 5 a ceiling rose on the existing junction box or wooden block including connections etc. as required 69 erection of wall bracket or ceiling fittings of all sizes and shapes containing upto two gls lamps per fitting complete with all accessories including connections etc. as required 70 installation testing and commissioning of pre wired fluorescent fitting or compact fluorescent fitting of all types complete with all accessories and tube etc. directly on ceiling or wall including connections with 1.5 sqmm fr pvc insulated copper conductor single core cable and earthing etc. as required 71 providing and fixing following rating and breaking capacity mccb in existing cubicle panel board including drilling holes in cubicle panel making connections etc. as required 100 a 16 ka 72 supplying and fixing 5 a to 32 a rating 240or415 v 10 ka c curve miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc. as required single pole 6 amp 73 supplying and fixing following rating four pole three phase and neutral 415 v residual current circuit breaker rccb having a sensitivity current 30 ma in the existing mcb db complete with connections testing and commissioning etc. as required 63 amps 74 earthing with gi earth pipe 4.5 meter long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required 75 supplying and laying 25 mm into 5 mm g.i strip at 0.50 meter below ground as strip earth electrode including connection or terminating with gi nut bolt spring washer etc. as required. jointing shall be done by overlapping and with 2 sets of g.i nut bolt and spring washer spaced at 50 mm 76 fixing of lightning conductor finial single prong with base plate including holes etc. complete as required 77 providing and fixing g.i tape 20 mm into 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.for horizontal run 78 providing and fixing g.i tape 20 mm into 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. for vertical run 79 laying of one number pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as required upto 35or50 sq. 80 excavation for cable trench / foundation in soft soil including dressing of sides and ramming of ottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 meter 81 supply of 46inch 1200 mm sweep energy efficient 5 star high speed ceiling fan with electronic regulator size 150 watt make crompton complete in all respect as per specification and direction of eic. high breeze colour brown or ivopry 82 supply 1 into 40w led tube light make philips type bn 550 wled 20 to 300 led linea 83 supply and fixing of single phase energy meter kwh with box of model no. 1plcd meter 5 to 30a catno. wm1018csdl0bok make land t...

Central Coalfields Limited - Jharkhand

33932069 bids are invited for incoming spout insulator , outgoing spout insulator , fixed contact , moving contact , rose contact , rectifire unit , auxiliary contact , potential transformer , current transformer , incoming tank bushing insulator , outgoing tank bushing insulator...

Central Coalfields Limited - Jharkhand

33780593 replacement of deteriorated electric board switches, sockets, led bulbs, tube light, fan regulators ceiling rose, wires etc in all the offices and others places wherever are required at tapin north ocp hazaribagh area ...

Bharat Coking Coal Limited - Jharkhand

33534090 procurement of electrical items 1 item1 switch selector 136vs rotary 415v 3phase 2 item2 contact rose 3.3kv 400a ocb 3 item3 bushing insulator with stud 630amp, part no. medv174 ...

Steel Authority Of India Limited - Jharkhand

33447401 bids are invited for led lamps bulb is:16102 (q2) , non modular piano type domestic electrical switches is 3854 (q3) , non modular elecrical switches and accessories flush type is 3854 (q3) , fixed capacitors (fixed capacitor for single phase ac electric fan) is: 1709:1984 (q3) , ceiling rose is 371 (q3) ,piano type non modular domestic fan regulator is 11037(q3) , electrical plugs is 1293 (q3) , lamp sockets lampholder as per is:1258 (q3) , light emitting diode ledfixture led tube light (q3) total quantity : 800...

Central Coalfields Limited - Jharkhand

33427469 bids are invited for tripping coil , fixed contact , moving contact , rose contact , current transformer , potential transformer total quantity : 50...

Forest And Environment Department - Jharkhand

33365172 bids are invited for stone paving , paver block , carb stone , doobs grass , hedge , iron gabion , avenue tree , seaforthia palm tree , cephortia palm plant , scheffera gree plant , calceolaria hybrid , cyclamen hybrid , primula hybrid , salvia plant , tulip dutch hybrid variety , standard rose h.t.variety , adenium obesum plant , bamboo buddhavalley , cucus cirsuallis plant , drinking waterkiosk , tubewell and solar pump , sand , stone chips, boulder , cement , solar street light , steeldustbin , cast iron benches total quantity : 19445...

District Hospital - Jharkhand

33365168 supply of electric/office related material paper, tape, paper pin, tag, erazer, envelop, punch, stamp pad, spring sheet, ups battery rope, led bulb, bed switch cut out, pvc flexible, cyling rose, pvc tap, screw etc...

Central Coalfields Limited - Jharkhand

33347669 bids are invited for incoming spout insulator , outgoing spout insulator , fixed contact , moving contact , rose contact , rectifire unit , auxiliary contact , potential transformer , currenttransformer , incoming tank bushing insulator , outgoingtank bushing insulator total quantity : 57...

Bharat Coking Coal Limited - Jharkhand

33346485 procurement of electrical items for maintenance of switch at sub station=1 contact rose 3.3kv 400a ocb 2 shunt trip assy 230v / 110v ac, part no. uss016 3 no volt coil assy part no. bt1870s / st1870s ...

Central Coalfields Limited - Jharkhand

33301978 annual maintenance of lawn inside garden and removal of old earth from rose garden at chapri rest house, executive hostel gm bunglow and gm office of dhori area. ...

Nagar Palika Nigam - Jharkhand

33286089 construction of pcc road from bhuiyan toli devi mandap to h/o arun engineer & from rose bird school to devi mandap, shastri nagar in ward no. 25 under municipal corporation, hazaribag....

HDB Financial Services Limited - Jharkhand

33153211 auction sale of property all that half portion of nothem side in the second floor measuring super built up area 1000 sq ft consisting of rooms, hall,kitchen, lat bath etc and open terrace measruing area 1383 sq ft all the above items are falling in society sub plot no xxi, along with its advantages, privileges, services and amenities and right over all the common space like stair, garden.alley etc within the block commonly known as tube rose lane, being in portion of r.s plot no. 566 under r.s khata no.3 corresponding to new plot no.70 under new khata no.451 in the confined premises of ashiana gardens, sonar, situated in mouza sonari, p.s sonari, ward no.1 (jnac). plana no.1156 under the district sub registry office & town jamshedpur, district east singhbhum and state jharkhand the said deed is registered before the district sub registrar at jamshedpur vide book no.1 volume no 314 pages 177 198 being deed no.10317/8528 for the year 2010. and butted bounded as follows: north: open to sky and boundary wall of ashiana gardens. south: purchaser nij, east: open to sky and entrance, west: open to sky and sub plot no17. boundary of the open car parking space north: boundary wall, south: common area. east: boundary wall, west: baghirath kaur sachdevas car parkking....

Bharat Coking Coal Limited - Jharkhand

32703343 procurement of electrical items for different ht switches at different substation 1 switch selector 136 vs rtry 451v 3ph 2 contact rose 3.3kv, 400a ocb 3 bushing insulator with stud 630amp, part no. medv174 ...

Drinking Water And Sanitation Department - Jharkhand

32534073 e quotation for rate of materials for schedule rate jharkhand under d w and s division, medininagar 2022 23.= 1 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) 2 gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) 3 jute ( m337 ) 4 g.m. ferrules ( m922 ) 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 stop cocks ( m923 ) 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 g.m. full way valve ( m924 ) 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 g.m. non return valve verticle ( m925 ) 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 g.m. non return valve horizontal ( m926 ) 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 cocks ( m927 ) 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 chromium plated brass fittings ( m928 ) 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 connection pipe ( m929 ) 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 mirrors ( m931 ) 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) 194 ( b ) do 450 mm x 125 mm do 195 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) 198 c.p. liquid soap solution holder ( m935 ) 199 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) 205 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) 206 ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) 218 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 drain board. ( m944 ) 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 h.c.i. pipes ( m945 ) 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 h.c.i. fittings. ( m946 ) 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 c.i. cover with frame for manhole and inspection chamber. ( m947 ) 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 c.i. bracket pair for w.h.b. ( m948 ) 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) 311 rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) 312 pig lead ( m953 ) 313 yarn ( m954 ) 314 rubber gasket for c.i pipe of good quality ( m955 ) 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 cotton waste ( m956 ) 334 asbestos suta ( gland packing ) ( m957 ) 335 solvent cement ( m958 ) 336 hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) 337 cp & pvc fitting ( m960 ) 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 c.i special & pvc pipes ( m962 ) 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) 385 rcc esr ( m1030 ) 386 designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. 387 notes 388 the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) 389 the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. 390 for design having more than 6 columns, suitable bracing is obligatory. 391 plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed 392 irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 393 these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. 394 staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 395 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 396 all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 397 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 398 the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . 399 for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. 400 below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. 401 the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. 402 the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 403 12 to 16 m staging 2% per metre 404 16 to 20 m staging 3% per metre 405 20 m and above 4% per metre 406 for 17 m staging height, percentage calculation will be like below : 407 12 to 16 m 4 x 2 = 8% 408 16 & 17 m 1 x 3% = 3% total = 11% 409 for 21 m staging height, percentage calculation will be like below : 410 12 to 16 m 4 x 2 = 8% 411 16 to 20 m 4 x 3% = 12% 412 20& 21 m 1 x 4% = 4% total = 24% 413 following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . 414 notes 415 conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. 416 conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. 417 rates for rcc esrs 418 upto 25, 000 litres 419 cost of 25, 000 litres capacity 420 add for capacity above 25, 000 upto 50, 000 litres 421 cost of 50, 000 litres capacity 422 add for capacity above 50, 000 upto 75, 000 litres 423 cost of 75, 000 litres capacity 424 add for capacity above 75, 000 upto 1, 00, 000 litres 425 cost of 1, 00, 000 litres capacity 426 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 427 cost of 1, 50, 000 litres capacity 428 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 429 cost of 2, 00, 000 litres capacity 430 add for capacity above 2, 00, 000 upto 2, 50, 000 litres 431 cost of 2, 50, 000 litres capacity 432 add for capacity above 2, 50, 000 upto 3, 00, 000 litres 433 cost of 3, 00, 000 litres capacity 434 add for capacity above 3, 00, 000 upto 4, 00, 000 litres 435 cost of 4, 00, 000 litres capacity 436 add for capacity above 4, 00, 000 upto 5, 00, 000 litres 437 cost of 5, 00, 000 litres capacity 438 add for capacity above 5, 00, 000 upto 7, 50, 000 litres 439 cost of 7, 50, 000 litres capacity 440 add for capacity above 7, 50, 000 upto 10, 00, 000 litres 441 cost of 10, 00, 000 litres capacity 442 add for capacity above 10, 00, 000 upto 15, 00, 000 litres 443 cost of 15, 00, 000 litres capacity 444 add for capacity above 15, 00, 000 upto 20, 00, 000 litres 445 cost of 20, 00, 000 litres capacity 446 rcc gsr and sump ( m1031 ) 447 designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. 448 anti –termite treatment shall be given for under ground portion of the structure. 449 notes 450 the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) 451 only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. 452 entire structure shall be in m 300 only. 453 the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 454 the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. 455 the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. 456 g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. 457 for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. 458 cost of pump house is not included in these rates. 459 above rates are applicable for seismic zones 2, 3 and 4. 460 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 461 10% shall be added for sump if over head pump house is proposed. 462 note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. 463 rates for rcc gsrs and sumps 464 upto 25, 000 litres 465 cost of 25, 000 litres capacity 466 add for capacity above 25, 000 upto 50, 000 litres 467 cost of 50, 000 litres capacity 468 add for capacity above 50, 000 upto 75, 000 litres 469 cost of 75, 000 litres capacity 470 add for capacity above 75, 000 upto 1, 00, 000 litres 471 cost of 1, 00, 000 litres capacity 472 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 473 cost of 1, 50, 000 litres capacity 474 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 475 cost of 2, 00, 000 litres capacity 476 add for capacity above 2, 00, 000 upto 3, 00, 000 litres 477 cost of 3, 00, 000 litres capacity 478 add for capacity above 3, 00, 000 upto 5, 00, 000 litres 479 cost of 5, 00, 000 litres capacity 480 add for capacity above 5, 00, 000 upto 10, 00, 000 litres 481 cost of 10, 00, 000 litres capacity 482 addforcapacityabove10, 00, 000upto15, 00, 000 litres 483 cost of 15, 00, 000 litres capacity 484 add for capacity above 15, 00, 000 litres 485 note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. 486 unconventionalwater treatment plant ( m1032 ) 487 designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. 488 aeration fountain 489 inlet arrangements 490 mixing channel with ventury flume and flow measuring arrangement 491 inlet channel 492 flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes 493 tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance 494 rapid sand gravity filters all valve shall be glandless. 495 filter house 496 chemical house 497 alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 498 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. 499 tcl solution tank with mixing, carrying and dosing arrangement with piping. 500 bypass arrangement 501 external and internal electrification 502 laboratory equipments 503 wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. 504 wash water pumps with 100% standby 505 air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. 506 pure water sump of capacity equal to 1 hourpumping capacity. 507 pure water pump house over the sump / by the side of sump. 508 drainage arrangements 509 alum store 510 sanitary block with necessary water supply and drainage arrangements and internalwbm roads. 511 these rates are applicable for seismic zones 2, 3 and 4. 512 rates given below are inclusive of uplift pressure if any and dewatering during the entire work. 513 all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. 514 unconventional treatment plants less than 1 mld capacity shall not be constructed. 515 all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . 516 note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. 517 unconventional water treatment plant 518 fixed cost for 1 mld 519 add for capacity above 1 mld upto 2 mld 520 cost of 2 mld treatment plant 521 add for capacity above 2 mld upto 3 mld 522 cost of 3 mld treatment plant 523 conventionalwater treatment plant ( m1033 ) 524 designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . 525 aeration fountain plan are a not less than 0.625 square metre per mld 526 ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) 527 flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. 528 flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. 529 clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. 530 rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. 531 filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. 532 wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. 533 wash water pumps capacity to fill water tank in 1 hour with 100% standby. 534 air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . 535 chemical house in two storeys 536 ground floor to accommodate 7 days alum requirement and sundry storage. 537 first floor to accommodate alum and lime tanks.etc. 538 solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. 539 pure water sump and sump house. 540 capacity of sump – one hour of designed flow. 541 pump house pump house of required size over the sump or by the side. 542 store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. 543 vacuum feed type chlorinators make tobe approved by mjp. 544 conforming to i.s. 10533 a part ii 1983 545 rate for withdrawal 546 temperature kg. of chlorine discharge degree c per day ( cylinders ) 547 45 67 tonnes 548 10 6.359.50 110 549 15 10.75 16.10130 550 20 14.50 21.24254 551 27&above18.70 28.12315 552 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 553 100% standby shall be provided. 554 by pass arrangements c.i. or m.s. pipes. 555 disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe 556 for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete 557 drainage arrangements – rcc pipes up to plot boundary. 558 electrical installation – both internal and external including entire plant area. 559 laboratory equipment –as per requirement ( to be specified during tendering ) . 560 sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. 561 administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. 562 rates given below are inclusive of up lift pressure if any and dewatering during entire work. 563 all pipes condutes channels with20%overloading 564 these rates are applicable for seismic zones 2, 3 and 4. 565 all rcc structures shall be constructed in m 300. 566 note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . 567 conventional water treatment plant 568 above3 mld to upto 5 mld 569 cost of 5 mld treatment plant 570 add for capacity above 5mld upto 10 mld 571 cost of 10 mld treatment plant 572 add for capacity above 10 mld upto20 mld 573 cost of 20 mld treatment plant 574 add for capacity above 20 mld upto 50 mld 575 cost of 50 mld treatment plant 576 add for capacityabove 50 mld upto 100 mld 577 cost of 100 mld treatment plant 578 add for capacity above 100 mld 579 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) 580 300 mm dia for gpt 581 400 mm dia for hygpt 582 hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) 583 from 0 50 meter 584 from 51 125 meter 585 dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) 586 drillig upto 30 mtr depth below g. l. in rural area 587 drilling beyond 31 mtr upto 60 mtr below g. l. in rural area 588 trenchless ( m1038 ) 589 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 590 from 900 mm to 1000 mm dia 591 in soft soil 592 in hard soil 593 in sandy soil 594 in stone soil 595 from 1000 mm to 1200 mm dia 596 in soft soil 597 in hard soil 598 in sandy soil 599 in stone soil 600 above 1200 mm to 1500 mm dia 601 in soft soil 602 in hard soil 603 in sandy soil 604 in stone soil 605 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 606 upto 300 mm dia 607 in soft soil 608 in hard soil 609 in sandy soil 610 in stone soil 611 above300 mm to 450 mm dia 612 in soft soil 613 in hard soil 614 in sandy soil 615 in stone soil 616 above 450 mm to 600 mm dia 617 in soft soil 618 in hard soil 619 in sandy soil 620 in stone soil 621 above 600 mm to 900 mm dia 622 in soft soil 623 in hard soil 624 in sandy soil 625 in stone soil 626 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 627 upto 300 mm dia 628 in soft soil 629 in hard soil 630 in sandy soil 631 in stone soil 632 above300 mm to 450 mm dia 633 in soft soil 634 in hard soil 635 in sandy soil 636 in stone soil 637 above 450 mm to 600 mm dia 638 in soft soil 639 in hard soil 640 in sandy soil 641 in stone soil 642 above 600 mm to 900 mm dia 643 in soft soil 644 in hard soil 645 in sandy soil 646 in stone soil 647 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) 648 without byepass arrangement pn 1 649 50 mm 650 65 mm 651 80 mm 652 100 mm 653 125 mm 654 150 mm 655 200 mm 656 250 mm 657 300 mm 658 350 mm 659 400 mm 660 450 mm 661 500 mm 662 600 mm 663 700 mm 664 750 mm 665 800 mm 666 900 mm 667 1000 mm 668 1100 mm 669 1200 mm 670 with byepass arrangement pn 1 671 50 mm 672 65 mm 673 80 mm 674 100 mm 675 125 mm 676 150 mm 677 200 mm 678 250 mm 679 300 mm 680 350 mm 681 400 mm 682 450 mm 683 500 mm 684 600 mm 685 700 mm 686 750 mm 687 800 mm 688 900 mm 689 1000 mm 690 1100 mm 691 1200 mm 692 without byepass arrangement pn 1.6 693 50 mm 694 65 mm 695 80 mm 696 100 mm 697 125 mm 698 150 mm 699 200 mm 700 250 mm 701 300 mm 702 350 mm 703 400 mm 704 450 mm 705 500 mm 706 600 mm 707 with byepass arrangement pn 1.6 708 50 mm 709 65 mm 710 80 mm 711 100 mm 712 125 mm 713 150 mm 714 200 mm 715 250 mm 716 300 mm 717 350 mm 718 400 mm 719 450 mm 720 500 mm 721 600 mm 722 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 723 with byepass arrangement pn 1 724 50 mm 725 65 mm 726 80 mm 727 100 mm 728 125 mm 729 150 mm 730 200 mm 731 250 mm 732 300 mm 733 350 mm 734 400 mm 735 450 mm 736 500 mm 737 600 mm 738 700mm 739 750 mm 740 800 mm 741 900 mm 742 1000 mm 743 1100 mm 744 1200mm 745 without byepass arrangement pn 1 746 50 mm 747 65 mm 748 80 mm 749 100 mm 750 125 mm 751 150 mm 752 200 mm 753 250 mm 754 300 mm 755 350 mm 756 400 mm 757 450 mm 758 500 mm 759 600 mm 760 700mm 761 750 mm 762 800 mm 763 900 mm 764 1000 mm 765 1100 mm 766 1200mm 767 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 768 without byepass arrangement pn 1.6 769 50 mm 770 65 mm 771 80 mm 772 100 mm 773 125 mm 774 150 mm 775 200 mm 776 250 mm 777 300 mm 778 350 mm 779 400 mm 780 450 mm 781 500 mm 782 600 mm 783 700mm 784 750 mm 785 800 mm 786 900 mm 787 1000 mm 788 1100 mm 789 1200mm 790 with byepass arrangement pn 1.6 791 50 mm 792 65 mm 793 80 mm 794 100 mm 795 125 mm 796 150 mm 797 200 mm 798 250 mm 799 300 mm 800 350 mm 801 400 mm 802 450 mm 803 500 mm 804 600 mm 805 design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . ( m1040 ) 806 dia 06 inch ( 150 mm ) 807 id 153 mm od 167 mm 808 screen thickness 07 mm 809 slot 1.00 mm 810 moc lowcarbon galvenised steel 811 length 5 mtr. 812 dia 08 inch ( 200 mm ) 813 id 205 mm od 221mm 814 screen thickness 08 mm 815 slot 1.00 mm 816 moc lowcarbon galvenised steel 817 length 5 mtr. 818 dia 10 inch ( 250 mm ) 819 id 256 mm od 276mm 820 screen thickness 10 mm 821 slot 1.00 mm 822 moc lowcarbon galvenised steel 823 length 5 mtr. 824 dia 12 inch ( 300 mm ) 825 id 306 mm od 326 mm 826 screen thickness 10 mm 827 slot 1.00 mm 828 moc lowcarbon galvenised steel 829 length 5 mtr. 830 dia 14 inch ( 350 mm ) 831 id 338 mm od 363 mm 832 screen thickness 12.5 mm 833 slot 1.00 mm 834 moc lowcarbon galvenised steel 835 length 5 mtr. 836 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) 837 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) 838 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) 839 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) 840 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) 841 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) 842 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) 843 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) 844 supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) 845 supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) 846 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) 847 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) 848 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) 849 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) 850 packaged lamella clarified type wtp with mgf capacity in mld. 851 0.2 852 0.3 853 0.4 854 0.5 855 0.6 856 pumps ( m1055 ) 857 supplying100 mm dia submersible pump sets confirming to is 8034 and motor confirming to is 9283. pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene / noryl impeller. motor suitable for working on 415v+10%, 3ph, 50 hz, a.c. supply with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. pump shall have suitable outlet as per manufacturers design. anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump. 858 submersible pump set 100 mm dia ( with polypropylene / noryl impeller ) up to 20 stages 859 1 h.p. 860 1.5hp 861 2 hp 862 2.5 hp 863 3.0 hp 864 4.0 hp 865 5.0 hp 866 supply rate should be increased by rs 200 / per stage for pump with more than 20 stages 867 submersible pump 150 mm dia ( with bronze impeller ) up to 8 stages 868 1.5 hp 869 2.0 hp 870 3.0 hp 871 4.0 hp 872 5.0 hp 873 6.0 hp 874 7.5 hp 875 supply rate should be increased by rs 600 / per stage for pump with more than 8 stages 876 submersible pump 150 mm dia ( with bronze impeller ) up to 12 stages 877 8.0 hp 878 9.0 hp 879 10.0 hp 880 11.0 hp 881 12.5 hp 882 15.0 hp 883 supply rate should be increased by rs 600 / per stage for pump with more than 12 stages 884 submersible pump 150 mm dia ( with bronze impeller ) up to 20 stages 885 17.5 hp 886 20.0 hp 887 25 hp 888 1 ) supply rate should be increased by rs 600 / per stage for pump with more than 20 stages for bore well only. 889 for other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump. 890 2 ) for 150 mm dia energy efficient pumps add as below 891 a. up to 8 stages : 3% on supply rate 892 b. up to 12 stages : 4% on supply rate 893 c. up to 15 stages : 5% on supply rate 894 pressure gauge ( m1056 ) 895 providing fabricating, testing and commisioning pressure vessel fabricating in m.s plate on providing foundation including epoxy paint 896 pressure gauge ( 100 mm dia ) 897 pressure gauge ( 150 mm dia ) 898 vacuum / combination gauge 899 supplyingvacuum gauge / combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia g.i. pipe. 900 vacuum / combination gauge – 100 mm dia 901 vacuum / combination gauge – 150 mm dia 902 lifting equipment ( m1057 ) 903 chain pulley block 904 supplyingtriple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 905 1 tonne capacity 906 2 tonne capacity 907 3 tonne capacity 908 hand operated circular or rectangular travelling crane ( single girder ) 909 supplyingsingle girder hand operated circular / rectangular travelling crane with 6 m lift complete with chain pulley block isi marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete. 910 3 tonne capacity 911 up to 5 m span 912 above 5 m up to 6 m span 913 above 6 m up to 8 m span 914 5 tonne capacity 915 up to 5 m span 916 above 5 m up to 6 m span 917 above 6 m up to 8 m span 918 above 8 m up to 10 m span 919 electric operated circular or rectangular travelling crane ( single girder ) 920 supplying single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class ii duty, all three motions electrically operated by suitable rating motor ip 54, control panel and down pendant control block. 921 5 tonne capacity 922 above 6 m up to 8 m span 923 above 8 m up to 10 m span 924 7.5 tonne capacity 925 above 6 m upto 8 m span 926 above 8 m up to 10 m span 927 10 tonne capacity 928 above 6 m up to 8 m span 929 above 8 m up to 10 m span 930 square bar / rail 931 providing, erecting and fixing square bar of en 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and “j” bolts. 932 50 x 50 mm ( en 8 ) 933 40 x 40 mm ( en 8 ) 934 lightening arrester, ab switch, insulators ( m1058 ) 935 lightening arrestor 936 supplying, erecting approved make thyrite type lightening arrestor suitable for h.t. supply with necessary ancillary material complete on provided cross arm and connected to overhead line. 937 suitable for 11 kv supply, distribution class 938 suitable for 22 kv supply, distribution class 939 suitable for 33 kv supply, station class 940 disc insulator 941 supplying, erecting porcelain disc type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 942 suitable for 11kv line 943 suitable for 33kv line 944 pin insulator 945 supplying, erecting porcelain pin type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 946 suitable for 11kv line 947 suitable for 33kv line 948 air break switch without earth switch 949 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 950 suitable for 11kv line 951 rocking / tilting type 952 rotating type 953 suitable for 33kv line 954 rocking / tilting type 955 rotating type 956 air break switch with earth switch 957 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 958 suitable for 11kv line 959 rotating type 960 suitable for 33kv line 961 rotating type 962 drop out fuse ( channel mounted ) 963 supplying, erecting approved make out door type drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working currentup to 50 amp, capacity completeerected on provided cross arm, each set comprising 3 units 964 suitable for 11 kv line 965 suitable for 33 kv line 966 horn gap fuse ( channel mounted ) 967 supplying, erecting approved make out door type horn gap type fuse with insulator, fuse element, with working current up to 50 amp, capacity complete erected on provided cross arm, each set comprising 3 units 968 suitable for 11 kv line 969 suitable for 33 kv line 970 transformer ( m1059 ) 971 power transformer ( with off load tap changer ) any isi mark 972 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 973 1. oil conservator with filling hole with cap and plain oil level gauge. 974 2. silica gel dehydrating breather charged with silica gel. 975 3. oil drain valve 976 4. oil filter valve 977 5. lifting eyes / hooks 978 6. two earthing terminals 979 7. diagram and rating plate 980 8. air vent 981 9. explosion vent 982 10. 100mm dia thermo meter with thermometer pocket 983 11. four bi directional plain roller. 984 power transformer 11000 / 433 volts with off load tap changer – 12.5% to +2.5% in steps of 2.5% as per bis level 2. 985 63 kva ( no load loss 180w and load loss 1235w ) 986 100 kva ( no load loss 260w and load loss 1760w ) 987 160kva ( no load loss 260w and load loss 1760w ) 988 200kva ( no load loss 500w and load loss3000w ) 989 250kvaa ( no load loss 550w and load loss3600w ) 990 315kva ( no load loss 580w and load loss 4200w ) 991 400 kva ( no load loss 715w and load loss 5000w ) 992 500 kva ( no load loss 850w and load loss 5800w ) 993 630 kva ( no load loss 1000w and load loss 7000w ) 994 750 kva ( no load loss 1500w and load loss 8000w ) 995 power transformer ( with on load tap changer ) 996 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. the oltc should be suitable for minimum 50 operations per day. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 997 1. oil conservator with filling hole with cap and plain oil level gauge. 998 2. silica gel dehydrating breather charged with silica gel. 999 3. oil drain valve 1000 4. oil filter valve 1001 5. lifting eyes / hooks 1002 6. two earthing terminals 1003 7. diagram and rating plate 1004 8. air vent 1005 9. explosion vent 1006 10. 100mm dia thermo meter with thermometer pocket 1007 11. four bi directional plain roller. 1008 12. buchholz relay 1009 13. resistance temp. detector 1010 14. marshalling box 1011 15. automatic voltage regulator ( avr ) 1012 16. remote tap changing controller ( rtcc ) 1013 transformer 11000 / 433 volts withon load tap changer – 15% to +5% in steps of 1.25% with rtcc, avr and marshalling box and other specification as per bis level 2. 1014 750 kva 1015 1000 kva 1016 1250 kva 1017 1600 kva 1018 2000 kva 1019 motors ( m1060 ) 1020 foot mounted motors tefc 1500 rpm 1021 supplyingfoot mounted tefc 1500 rpm, squirrel cage induction motor, conforming to is 325 having continuous rating suitable for operation at 415 volts + / 10%, 3 phase, 50 hz + / 3% with “f” class insulation temperature rise limited to class “b” insulation. motors conform to is 12615 with efficiency level ie3 and provided with enclosure protection class ip 55. 1022 15 kw ( 20 hp ) 1023 18.5 kw ( 25 hp ) 1024 22 kw ( 30 hp ) 1025 30 kw ( 40 hp ) 1026 37 kw ( 50 hp ) 1027 45 kw ( 60 hp ) 1028 55 kw ( 75 hp ) 1029 75 kw ( 100 hp ) 1030 90 kw ( 120 hp ) 1031 110 kw ( 150 hp ) 1032 132kw ( 180hp ) 1033 160kw ( 215 hp ) 1034 250kw ( 335 hp ) 1035 foot mounted motor tefc 1500 rpm 1036 0.75 kw ( 1hp ) 1037 1.1 kw ( 1.5 hp ) 1038 1.5 kw ( 2 hp ) 1039 2.2 kw ( 3 hp ) 1040 3.7 kw ( 5 hp ) 1041 5.5 kw ( 7.5 hp ) 1042 7.5 kw ( 10 hp ) 1043 9.3 kw ( 12.5 hp ) 1044 11 kw ( 15 hp ) 1045 aluminium cable ( m1061 ) 1046 cable 1047 aluminium conductor three core, xlpe / pvc insulated & armoured cable . 1048 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1049 3 core 2.5 sq mm 1050 3 core 4 sq mm 1051 3 core 6 sq mm 1052 3 core 10 sq mm 1053 3 core 16 sq mm 1054 3 core 25 sq mm 1055 3 core 35 sq mm 1056 3 core 50 sq mm 1057 3 core 70 sq mm 1058 3 core 95 sq mm 1059 3 core 120 sq mm 1060 3 core 150 sq mm 1061 3 core 185 sq mm 1062 3 core 240 sq mm 1063 3 core 300 sq mm 1064 3 core 400 sq mm 1065 aluminium conductor 3.5 core, xlpe / pvc insulated & unarmoured cable 1066 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three and half core, stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1067 3.5 core 25 sq mm 1068 3.5 core 35 sq mm 1069 3.5 core 50 sq mm 1070 3.5 core 70 sq mm 1071 3.5 core 95 sq mm 1072 3.5 core 120 sq mm 1073 3.5 core 150 sq mm 1074 3.5 core 185 sq mm 1075 3.5 core 240 sq mm 1076 3.5 core 300 sq mm 1077 3.5 core 400 sq mm 1078 ht aluminium three core 3.3 kve cable xlpe insulated 1079 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1080 3 core 35 sq mm 1081 3 core 50 sq mm 1082 3 core 70 sq mm 1083 3 core 95 sq mm 1084 3 core 120 sq mm 1085 3 core150sq mm 1086 3 core 185 sq mm 1087 3 core 240sq mm 1088 3 core 300 sq mm 1089 3 core 400 sq mm 1090 ht aluminium three core 6.6 kv ( ue ) / 11kv ecable xlpe insulated 1091 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1092 3 core 35 sq mm 1093 3 core 50 sq mm 1094 3 core 70 sq mm 1095 3 core 95 sq mm 1096 3 core 120 sq mm 1097 3 core150sq mm 1098 3 core 185 sq mm 1099 3 core 240sq mm 1100 3 core 300 sq mm 1101 3 core 400 sq mm 1102 ht aluminium three core 11kv ( ue ) cable xlpe insulated 1103 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1104 3 core 35 sq mm 1105 3 core 50 sq mm 1106 3 core 70 sq mm 1107 3 core 95 sq mm 1108 3 core 120 sq mm 1109 3 core150sq mm 1110 3 core 185 sq mm 1111 3 core 240sq mm 1112 3 core 300 sq mm 1113 3 core 400 sq mm 1114 aluminium conductor three core, xlpe / pvc insulated & unarmoured cable . 1115 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1116 3 core 4 sq mm 1117 3 core 6 sq mm 1118 3 core 10 sq mm 1119 3 core 16 sq mm 1120 3 core 25 sq mm 1121 3 core 35 sq mm 1122 3 core 50 sq mm 1123 3 core 70 sq mm 1124 3 core 95 sq mm 1125 3 core 120 sq mm 1126 3 core 150 sq mm 1127 3 core 185 sq mm 1128 3 core 240 sq mm 1129 3 core 300 sq mm 1130 3 core 400 sq mm 1131 copper cable ( m1062 ) 1132 cable 1133 3 core pvc insulated, pvc sheathed copper conductor flat submersible cable . 1134 supplying , flat flexible submersible cable with, copper conductor, pvc insulated, and pvc sheathed . 1135 3 core 1.5 sq mm 1136 3 core 2.5 sq mm 1137 3 core 4 sq mm 1138 3 core 6 sq mm 1139 3 core 10 sq mm 1140 3 core 16 sq mm 1141 3 core 25 sq mm 1142 3 core 35 sq mm 1143 copper conductor three core, xlpe / pvc insulated & unarmoured cable . 1144 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1145 3 core 1.5 sq mm 1146 3 core 2.5 sq mm 1147 3 core 4 sq mm 1148 3 core 6 sq mm 1149 3 core 10 sq mm 1150 3 core 16 sq mm 1151 3 core 25 sq mm 1152 3 core 35 sq mm 1153 3 core 50 sq mm 1154 3 core 70 sq mm 1155 3 core 95 sq mm 1156 copper conductor 3.5 core, xlpe / pvc insulated & armoured cable . 1157 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1158 3.5 core 1.5 sq mm 1159 3.5 core 2.5 sq mm 1160 3.5 core 4 sq mm 1161 3.5 core 6 sq mm 1162 3.5 core 10 sq mm 1163 3.5 core 16 sq mm 1164 3.5 core 25 sq mm 1165 3.5 core 35 sq mm 1166 3.5 core 50 sq mm 1167 3 .5 core 70 sq mm 1168 3.5 core 95 sq mm 1169 3.5 core 120 sq mm 1170 3 .5 core150sq mm 1171 3.5 core 185 sq mm 1172 3.5 core 240sq mm 1173 3.5 core 300 sq mm 1174 3.5 core 400 sq mm 1175 copper conductor 3.5 core xlpe / pvcunarmoured 1176 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1177 3.5core 25 sq mm 1178 3.5core 35 sq mm 1179 3.5 core 50 sq mm 1180 3.5 core 70 sq mm 1181 3.5 core 95 sq mm 1182 3.5 core 120 sq mm 1183 3.5 core150sq mm 1184 3.5 core 185 sq mm 1185 3.5 core 240sq mm 1186 3.5 core 300 sq mm 1187 3.5 core 400 sq mm 1188 copper conductor three core, xlpe / pvc insulated & armoured cable . 1189 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1190 3 core 1.5 sq mm 1191 3 core 2.5 sq mm 1192 3 core 4 sq mm 1193 3 core 6 sq mm 1194 3 core 10 sq mm 1195 3 core 16 sq mm 1196 3 core 25 sq mm 1197 3 core 35 sq mm 1198 3 core 50 sq mm 1199 3 core 70 sq mm 1200 3 core 95 sq mm 1201 3 core 120 sq mm 1202 3 core 150sq mm 1203 3core 185 sq mm 1204 3 core 240 sq mm 1205 3 core 300 sq mm 1206 3 core 400 sq mm 1207 foot valve ( m1063 ) 1208 foot valve 1209 supplying c.i. foot valve having single leather flap and gunmetal seating. valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. 1210 flanged type 1211 50 mm 1212 65 mm 1213 80 mm 1214 100 mm 1215 125 mm 1216 150 mm 1217 aircircuit breaker ( m1064 ) 1218 acbbreaking capacity 50ka thermal magnetic manual draw out type 3 pole 1219 630a 1220 800a 1221 1000a 1222 1250a 1223 1600a 1224 2000a 1225 starter ( m1065 ) 1226 d.o.l. starter with ss enclosure with 380 / 415 volt coil 1227 7.5 h.p. 1228 10 h.p. 1229 supplyingfully automatic star delta starter to operate induction motor working on415v, 3phase, 50 hz with no volt coil, over load element, on off push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser 1230 f.a.s.d starter 1231 10.0 h.p. 1232 15 h.p. 1233 20 h.p. 1234 25 h.p. 1235 35 h.p. 1236 40 hp 1237 50 hp 1238 75 h.p. 1239 100 h.p. 1240 125 h.p. 1241 150 h.p. 1242 250 h.p. 1243 servo controlled automatic voltage stabilizer ( m1066 ) 1244 providing, erecting servo controlled automatic voltage stabiliser suitable for out put voltage of 415 volt + / 1%, 3 ph, 50 hz, with copper wound transformer ( air / oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, auto / manual selector switch, raise / low push buttons etc. suitable capacity termination strips and bus bars for incoming and out going cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated 􀂌 over voltage / under voltage 􀂌 single phasing 􀂌 cut off contactor with electronic output sensing unit 1245 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 150 to 450 volt 1246 20 kva air cooled 1247 25 kva air cooled 1248 30 kva air cooled 1249 40 kva air cooled 1250 50 kva oil cooled 1251 60 kva oil cooled 1252 75 kva oil cooled 1253 100 kva oil cooled 1254 125 kva oil cooled 1255 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 280 to 460 volt 1256 15 kva air cooled 1257 20 kva air cooled 1258 25 kva air cooled 1259 30 kva air cooled 1260 40 kva air cooled 1261 50kva air cooled 1262 60 kva oil cooled 1263 75kva oil cooled 1264 100 kva oil cooled 1265 125 kva oil cooled 1266 150 kva oil cooled 1267 200kva oil cooled 1268 250kva oil cooled 1269 300 kva oil cooled 1270 400 kva oil cooled 1271 termination kit ( m1067 ) 1272 providing and errecting in door type termination kit, for 3.3kv / 6.6 kv / 11kv / 22kv / 33kv xlpe screened 3 core cable 1273 in door termination kit for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1274 25 50 mm2 1275 70 120 mm2 1276 150 185 mm2 1277 240 400 mm2 1278 out door termination kit for 3.3 ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1279 25 50 mm2 1280 70 120 mm2 1281 150 185 mm2 1282 240 400 mm2 1283 straight through joint for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1284 25 50 mm2 1285 70 120 mm2 1286 150 185 mm2 1287 240 300 mm2 1288 in door termination kit for 11kv ( e ) xlpe screened 3 core cable 1289 25 50 mm2 1290 70 120 mm2 1291 150 185 mm2 1292 240 400 mm2 1293 out door termination kit for 11kv ( e ) xlpe screened 3 core cable 1294 25 50 mm2 1295 70 120 mm2 1296 150 185 mm2 1297 240 400 mm2 1298 straight through joint for 11 kv ( e ) xlpe screened 3 core cable 1299 25 50 mm2 1300 70 120 mm2 1301 150 185 mm2 1302 240 300 mm2 1303 in door termination kit for 22kv ( e ) xlpe screened 3 core cable 1304 25 50 mm2 1305 70 120 mm2 1306 150 185 mm2 1307 240 400 mm2 1308 out door termination kit for 22kv ( e ) xlpe screened 3 core cable 1309 25 50 mm2 1310 70 120 mm2 1311 150 185 mm2 1312 240 400 mm2 1313 straight through joint for 22 kv ( e ) xlpe screened 3 core cable 1314 25 50 mm2 1315 70 95 mm2 1316 120 150 mm2 1317 185 240 mm2 1318 300 400 mm2 1319 in door termination kit for 33kv ( e ) xlpe screened 3 core cable 1320 25 50 mm2 1321 70 95 mm2 1322 120 185 mm2 1323 240 400 mm2 1324 out door termination kit for 33 kv ( e ) xlpe screened 3 core cable 1325 25 50 mm2 1326 70 95 mm2 1327 120 185 mm2 1328 240 400 mm2 1329 straight through joint for 33 kv ( e ) xlpe screened 3 core cable 1330 35 70 mm2 1331 95 150 mm2 1332 185 300 mm2 1333 400 mm2...

Department Of Atomic Energy - Jharkhand

32511377 bids are invited for construction of change room in mill area at turamdih title1 clearing jungle including uprooting of rank vegetation grass brush wood trees and saplings of girth upto 30 cm measured at a height of 1 metre above ground level and removal of rubbish up to a distance of 50 mtr out side the peripfery of the area cleared. title2 earth work in excavation in the following types of soil and rock up to and including 1.5 mtr lead including bailing or pumping out any water accumulating inside the excavated pit or trench shoring strutting as directed by engineer adequate protection to be taken during excavation or drilling or blasting transporting the excavated soil for all lead and stacking selectively including disposing off the rubbish rock fragments excess spoils etc lead upto 100 mtrs in the area as directed by the engineer all complete as per drawing specification and direction of the engineer. all types of soil title3 earth work in back filling with available earth including watering and compaction at all elevations around foundations walls wells tunnels pits culverts trenches road approaches and in plinth filling and area filling as per specifications and drawings and as directed by the engineer with selected spoil within a lead of 100 mtr. title4 disposal or carriage of rubbish or waste rock or earth etc dumped or stacked at site by mechanical means including loading unloading and dressing properly lead upto 5 km and up to any lift includind cost of all labours and equipments. title5 supply mix, place in position, compact and cure cement concrete one cement isto three coarse sand isto 6 graded stone aggregate 20 mm nominal size below foundations walls wells pits trenches etc and in basin lining as per specifications drawings and directions of the engineer and including cost of centring and shuttering but excluding cost of cement. title6 supply mix place in position compact and cure including testing of concrete specimens finishing surfaces as per specifications drawings and directions of the engineer of the following grades of concrete with 20mm and down graded stone aggregate and coarse sand in foundations excluding cost of cement centring shuttering and reinforcement m20 rcc title7 supply mix place in position compact and cure including testing of concrete specimens finishing surfaces as per specifications drawings and directions of the engineer of the following grades of concrete with 20mm and down graded stone aggregate and coarse sand in super structure excluding cost of cement centring shuttering and reinforcement m20 rcc title8 taking delivery from store or departmental yard bend bind and place the following types of reinforcement in all types of reinforced concrete work at all elevations including cleaning straightening cutting bending and binding with 18 swg annealed wire or with welding such as tack lap butt etc with approved electrodes providing concrete cover blocks pins chairs nails supports of reinforcement etc with all materials and labour complete as per drawings specifications and directions of engineer excluding cost of reinforcement. title9 install dismantle and remove the form work of approved quality including splay recess corners haunch etc scaffolding and necessary rendering of concrete surfaces after exposure including cost of all material and labours at all elevations. title10 supply and laying in position brick work with designate 75 bricks compressive strength not less than 75 kg per sqcm in foundation upto plinth etc in cement coarse sand mortar 1 isto 6 including mixing mortar laying bricks raking joints curing etc complete with all materials and labour as per drawings and specifications. title11 supply and laying in position brick work with designate 75 bricks compressive strength not less than 75 kg per sqcm in super structures etc in cement coarse sand mortar 1 isto 6 including mixing mortar laying bricks raking joints curing etc complete with all materials and labour as per drawings and specifications excluding cost of cement. title12 half brick masonry with common burnt clay fps. non modular bricks of class designation 7.5 in foundations and plinth in cement mortar 1 isto 4 one cement isto four coarse sand excluding cost of cement. title13 15mm thick minimum plastering with 1 isto 6 one cement isto six coarse sand to all faces of walls channels in roof and other structures at various elevations including mixing laying finishing curing and necessary scaffolding work complete as per drawings specifications and instructions of the engineer with all materials and labours excluding cement. title14 6 mm thick cement plaster of mix 1 isto 3 one cement isto 3 fine sand all complete as per direction of engineer in charge excluding cost of cement. title15 applying neat cement punning including cost of all materials labours etc complete as per direction of engineer in charge excluding cost of cement title16 providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption less than 0.08 percent and conforming to is 15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1 isto 4 one cement isto four coarse sand jointing with grey cement slurry at rate of 3.3 kg per sqm including grouting the joints with white cement and matching pigments etc complete size of tile 600 into 600 mm title17 providing and fixing ist quality ceramic glazed wall tiles conforming to is 15622 thickness to be specified by the manufacturer of approved make in all colours shades except burgundy bottle green black of any size as approved by eic in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 isto 3 one cement isto 3 coarse sand and jointing with grey cement slurry at rate of 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. title18 supplying and applying two or more coats of white wash with lime to walls ceiling etc at various elevations including preparation of surfaces cleaning etc.complete with all materials labour scaffolding work as per specifications . title19 supplying and finishing walls with acrylic smooth exterior paint of required shade new work two or more coat applied at rate of 1.67 ltr per10 sqm over and including priming coat of exterior primer applied at rate of 2.20 kg per10 sqm all complete as per direction of eic. title20 supplying fitting and fixing fully glazed steel door windows or ventilations of standard rolled z and mullton steel sections and size as per ls 1038 joints met and welded with 100 into16 into 3mm ms lugs fixing in cement concrete 1isto 2 isto 4 blocks 15 into10 into1ocm size including cost of oxidised iron fittings with hinges handle peg stays catch springs 3mm thick plain glass panes with aluminimum beads or glass putty and inner frame fixed with lugs with 20mm long 6.3mm gl counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of engineer. title21 providing and fixing 1mm thick ms sheet door with frame of 40 into 40 into 6 mm angle iron and 3 mm ms gusset plates at the junctions and corners all necessary fittings complete including applying a priming coat of approved steel primer. using flats 30 into 6mm for diagonal braces and central cross piece. title22 providing and fixing glass panes with putty and glazing clips in steel doors windows clerestory windows all complete with 4.0 mm thick glass panes title23 painting with synthetic enamel paint of approved brand and manufacturer of required colour to give an even shade two or more coats on new or old work over a priming coat complete as per specification and direction of eic. title24 making plinth protection 50mm thick of cement concrete 1 isto 3 isto6 one cement isto three coarse sand zone iii isto 6 graded stone aggregate 20 mm nominal size over 75mm thick bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling and dressing and finishing the top smooth. title25 providing and fixing water closet squatting pan indian type wc pan with 100 mm sand cast iron p or s trap 10 litre low level white pvc flushing cistern including flush pipe with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern wc pan of size 580 into 440 mm with integral type foot rests. title26 providing and fixing white vitreous china pedestal type water closet european type wc pan with seat and lid 10 litre low level white pvc flushing cistern including flush pipe with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required wc pan with isi marked black solid plastic seat and lid title27 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 into 260 into 350 mm and 340 into 410 into 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and cp brass spreaders with brass unions and gi clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required range of two urinal basins with 5 litre white pvc automatic flushing cistern title28 providing and fixing wash basin with ci brackets 15 mm cp brass pillar taps 32 mm cp brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require white vitreous china wash basin size 630 into 450 mm with a single 15 mm cp brass pillar tap. title29 supply and fixinf p or s trap title30 providing and fixing cp brass shower rose with 15 or 20 mm inlet title31 providing and fixing 100 mm sand cast iron grating for gully trap. title32 providing and fixing 600 into 450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with cp brass screws and washers complete. title33 providing and fixing gi pipes complete with all gi fittings like tee elbow union reducer socket etc and clamps including cutting and making good the walls etc 15 mm dia nominal bore title34 providing and fixing gi pipes complete with all gi fittings like tee elbow union reducer socket etc and clamps including cutting and making good the walls etc 20 mm dia nominal bore title35 providing and fixing gi pipes complete with all gi fittings like tee elbow union reducer socket etc and clamps including cutting and making good the walls etc 25 mm dia nominal bore title36 providing and fixing cp brass long body bib cock of approved quality conforming to is 8931 15mm nominal bore title37 providing and fixing cp brass stop cock concealed of standard design and approved make conforming to is 8931 15mm nominal bore title38 providing and fixing gun metal gate valve with ci wheel of approved quality screwed end 25 mm nominal bore title39 providing and fixing gun metal gate valve with ci wheel of approved quality screwed end 50 mm nominal bore title40 providing and fixing ball valve brass of approved quality high or low pressure with plastic floats complete 25 mm nominal bore title41 providing and placing on terrace at all floor levels polyethylene water storage tank 2000 litres capacity is isto 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank. title42 providing and fixing pvc waste pipe for sink or wash basin including pvc waste fittings complete. 32 or 40 mm dia title43 providing and fixing uplasticised pvc connection pipe with brass unions 45 cm long 15 mm nominal bore title44 providing and fixing cp brass angle valve for basin mixer and geyser points of approved quality conforming to is8931 15mm nominal bore title45 making soak pit 2.5 m diameter 3 metre deep with 45 into 45 cm dry brick honey comb shaft with bricks and sw drain pipe 100 mm diameter 1.8 m long complete as per standard design with common burnt clay fps non modular bricks of class designation 7.5. title46 grading roof for water proofing treatment with cement concrete 1 isto 2 isto 4 one cement isto two coarse sand isto four graded stone aggregate 20mm nominal size all complete as per direction of eic excluding cost of cement. title47 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is isto 13592 type a including bend shoe other fittings and jointing with seal ring conforming to is 5382 leaving 10 mm gap for thermal expansion single socketed pipes 110 mm diameter title48 supplying assembling fixing in vertical and horizontal position in wall face or under ground unplasticized pvc medium cm pipe of required dia conforming to is12818 including required hire and labour charges fittings and accessories etc all complete for all depths as per direction of eic 100mm nominal size dia title49 supplying assembling fixing in vertical and horizontal position in wall face or under ground unplasticized pvc medium cm pipe of required dia conforming to is12818 including required hire and labour charges fittings and accessories etc all complete for all depths as per direction of eic 150 mm nominal bore title50 felling trees of the girth measured at a height of 1 m above ground level including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material all complete as per direction of eic. beyond 30 cm girth upto and including 60 cm girth...

Central Coalfields Limited - Jharkhand

32423980 annual maintenance of lawn inside garden and removal of old earth from rose garden at chapri rest house, executive hostel gm bunglow and gm office of dhori area ...

Drinking Water And Sanitation Department - Jharkhand

32408532 procurement of rate of materials 1 m079 polythene water storage tank of isi mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system 2 m193gi pipe 50 mm dia ( tata or equivalent make ) 3 m337jute 4 m922g.m. ferrules 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 m923stop cocks 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 m924g.m. full way valve 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 m925g.m. non return valve vertical 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 m926g.m. non return valve horizontal 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 m927 cocks 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 m928chromium plated brass fittings 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 m929connection pipe 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 m930g.i. fittings ( conforming to i.s. 1879 ) isi marked 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 m931mirrors 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 m932 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail 194 ( b ) do 450 mm x 125 mm do 195 m933 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 m934c.p. brass soap dish medium quality with screw andhinges etc. 198 m935c.p. liquid soap solution holder 199 m936vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 m937pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make 205 m93815 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket 206 m939 ( a ) 12.5 liters lowdown c.i. cistern 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 m940 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 m941 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 m942white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make 218 m943white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 m944drain board 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 m945h.c.i. pipes 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 m946h.c.i. fittings. 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 m947c.i. cover with frame for manhole and inspection chamber 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 m948c.i. bracket pair for w.h.b 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 m949 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 m950 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 m95132 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern 311 m952rubber inserttion 3 mm ( 1 / 8 ) thick 312 m953pig lead 313 m954yarn 314 m955rubber gasket for c.i pipe of good quality 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 m956cotton waste 334 m957asbestos suta ( gland packing ) 335 m958solvent cement 336 m959hydrocloric acid ( sepecific gravity 1.20 ) 337 m960cp & pvc fitting 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 m961special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 m962c.i special & pvc pipes 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 m1038trenchless 385 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 386 from 900 mm to 1000 mm dia 387 in soft soil 388 in hard soil 389 in sandy soil 390 in stone soil 391 from 1000 mm to 1200 mm dia 392 in soft soil 393 in hard soil 394 in sandy soil 395 in stone soil 396 above 1200 mm to 1500 mm dia 397 in soft soil 398 in hard soil 399 in sandy soil 400 in stone soil 401 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 402 upto 300 mm dia 403 in soft soil 404 in hard soil 405 in sandy soil 406 in stone soil 407 above300 mm to 450 mm dia 408 in soft soil 409 in hard soil 410 in sandy soil 411 in stone soil 412 above 450 mm to 600 mm dia 413 in soft soil 414 in hard soil 415 in sandy soil 416 in stone soil 417 above 600 mm to 900 mm dia 418 in soft soil 419 in hard soil 420 in sandy soil 421 in stone soil 422 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 423 upto 300 mm dia 424 in soft soil 425 in hard soil 426 in sandy soil 427 in stone soil 428 above300 mm to 450 mm dia 429 in soft soil 430 in hard soil 431 in sandy soil 432 in stone soil 433 above 450 mm to 600 mm dia 434 in soft soil 435 in hard soil 436 in sandy soil 437 in stone soil 438 above 600 mm to 900 mm dia 439 in soft soil 440 in hard soil 441 in sandy soil 442 in stone soil 443 m1039providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) 444 without byepass arrangement pn 1 445 50 mm 446 65 mm 447 80 mm 448 100 mm 449 125 mm 450 150 mm 451 200 mm 452 250 mm 453 300 mm 454 350 mm 455 400 mm 456 450 mm 457 500 mm 458 600 mm 459 700 mm 460 750 mm 461 800 mm 462 900 mm 463 1000 mm 464 1100 mm 465 1200 mm 466 with byepass arrangement pn 1 467 50 mm 468 65 mm 469 80 mm 470 100 mm 471 125 mm 472 150 mm 473 200 mm 474 250 mm 475 300 mm 476 350 mm 477 400 mm 478 450 mm 479 500 mm 480 600 mm 481 700 mm 482 750 mm 483 800 mm 484 900 mm 485 1000 mm 486 1100 mm 487 1200 mm 488 without byepass arrangement pn 1.6 489 50 mm 490 65 mm 491 80 mm 492 100 mm 493 125 mm 494 150 mm 495 200 mm 496 250 mm 497 300 mm 498 350 mm 499 400 mm 500 450 mm 501 500 mm 502 600 mm 503 with byepass arrangement pn 1.6 504 50 mm 505 65 mm 506 80 mm 507 100 mm 508 125 mm 509 150 mm 510 200 mm 511 250 mm 512 300 mm 513 350 mm 514 400 mm 515 450 mm 516 500 mm 517 600 mm 518 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 519 with byepass arrangement pn 1 520 50 mm 521 65 mm 522 80 mm 523 100 mm 524 125 mm 525 150 mm 526 200 mm 527 250 mm 528 300 mm 529 350 mm 530 400 mm 531 450 mm 532 500 mm 533 600 mm 534 700mm 535 750 mm 536 800 mm 537 900 mm 538 1000 mm 539 1100 mm 540 1200mm 541 without byepass arrangement pn 1 542 50 mm 543 65 mm 544 80 mm 545 100 mm 546 125 mm 547 150 mm 548 200 mm 549 250 mm 550 300 mm 551 350 mm 552 400 mm 553 450 mm 554 500 mm 555 600 mm 556 700mm 557 750 mm 558 800 mm 559 900 mm 560 1000 mm 561 1100 mm 562 1200mm 563 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 564 without byepass arrangement pn 1.6 565 50 mm 566 65 mm 567 80 mm 568 100 mm 569 125 mm 570 150 mm 571 200 mm 572 250 mm 573 300 mm 574 350 mm 575 400 mm 576 450 mm 577 500 mm 578 600 mm 579 700mm 580 750 mm 581 800 mm 582 900 mm 583 1000 mm 584 1100 mm 585 1200mm 586 with byepass arrangement pn 1.6 587 50 mm 588 65 mm 589 80 mm 590 100 mm 591 125 mm 592 150 mm 593 200 mm 594 250 mm 595 300 mm 596 350 mm 597 400 mm 598 450 mm 599 500 mm 600 600 mm...

Drinking Water And Sanitation Department - Jharkhand

32333309 government of jharkhand through its public works department ( pwd ) is engaged in framing / revision of schedule of rates and as part of this endeavor quotations through e tender are invited for hire charges of plant and machines annexed as annexure 1 1 polytene water storage tank of mark ( e.g. sintex / sinter / himgiri / gangotietc ) with cover and locking system 2 hdpe pipe 75mm dia 3 hdpe pipe 90mm dia 4 gi pipe 50mm dia ( tata or equivalent make ) 5 jute 6 g.m. ferrules 7 ( i ) 8 mm dia wt. not less than 400 gms 8 ( ii ) 10 mm dia wt. not less than 400 gms 9 ( iii ) 15 mm dia wt. not less than 400 gms 10 ( iv ) 20 mm dia wt. not less than 600 gms 11 ( v ) 25 mm dia wt. not less than 900 gms 12 stop cocks 13 ( i ) 15 mm brass stop cock wt. not less than 300 gms 14 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 15 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 16 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 17 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 18 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 19 ( vii ) 15 mm dia c.i. body brass working part stop cock. 20 ( viii ) 20 mm dia c.i. body brass working part stop cock. 21 ( ix ) 25 mm dia c.i. body brass working part stop cock. 22 g.m. full way valve 23 ( i ) 15 mm dia wt. not less than 300 gms without wheel 24 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 25 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 26 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 27 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 28 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 29 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 30 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 31 g.m. non return valve verticle 32 ( i ) 15 mm dia wt. not less than 150 gms 33 ( ii ) 20 mm dia wt. not less than 250 gms 34 ( iii ) 25 mm dia wt. not less than 375 gms 35 ( iv ) 32 mm dia wt. not less than 600 gms 36 ( v ) 40 mm dia wt. not less than 700 gms 37 ( vi ) 50 mm dia wt. not less than 1.0 kg 38 ( vii ) 65 mm dia wt. not less than 1.20 kg 39 ( viii ) 80 mm dia wt. not less than 1.50 kg 40 ( ix ) 100 mm dia wt. not less than 1.80 kg 41 g.m. non return valve horizontal 42 ( i ) 15 mm dia wt. not less than 150 gms 43 ( ii ) 20 mm dia wt. not less than 250 gms 44 ( iii ) 25 mm dia wt. not less than 375 gms 45 ( iv ) 32 mm dia wt. not less than 600 gms 46 ( v ) 40 mm dia wt. not less than 700 gms 47 ( vi ) 50 mm dia wt. not less than 1.0 kg 48 ( vii ) 65 mm dia wt. not less than 1.20 kg 49 ( viii ) 80 mm dia wt. not less than 1.50 kg 50 ( ix ) 100 mm dia wt. not less than 1.80 kg 51 cocks 52 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 53 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 54 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 55 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 56 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 57 ( vi ) 15 mm c.i. plug cock ordinary 58 ( vii ) 15 mm c.i. push cock ordinary 59 chromium plated brass fittings 60 ( i ) c.p. shower rose 100 mm dia 61 ( ii ) c.p. shower rose 125 mm dia 62 ( iii ) p.v.c. shower rose 150 mm dia 63 ( iv ) p.v.c shower rose 125 mm dia 64 connection pipe 65 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 66 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 67 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 68 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 69 g.i. fittings ( conforming to i.s. 1879 ) isi marked 70 [ a ] g.i. bend 71 ( i ) 15 mm 72 ( ii ) 20 mm 73 ( iii ) 25 mm 74 ( iv ) 32 mm 75 ( v ) 40 mm 76 ( vi ) 50 mm 77 ( vii ) 65 mm 78 ( viii ) 80 mm 79 ( ix ) 100 mm 80 ( x ) 125 mm 81 ( xi ) 150 mm 82 [ b ] elbow of the following sizes 83 ( i ) 15 mm 84 ( ii ) 20 mm 85 ( iii ) 25 mm 86 ( iv ) 32 mm 87 ( v ) 40 mm 88 ( vi ) 50 mm 89 ( vii ) 65 mm 90 ( viii ) 80 mm 91 ( ix ) 100 mm 92 ( x ) 125 mm 93 ( xi ) 150 mm 94 [ c ] tee plain of the following sizes 95 ( i ) 15 mm 96 ( ii ) 20 mm 97 ( iii ) 25 mm 98 ( iv ) 32 mm 99 ( v ) 40 mm 100 ( vi ) 50 mm 101 ( vii ) 65 mm 102 ( viii ) 80 mm 103 ( ix ) 100 mm 104 ( x ) 125 mm 105 ( xi ) 150 mm 106 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 107 ( i ) 20 mm 108 ( ii ) 25 mm 109 ( iii ) 32 mm 110 ( iv ) 40 mm 111 ( v ) 50 mm 112 ( vi ) 65 mm 113 ( vii ) 80 mm 114 ( viii ) 100 mm 115 ( ix ) 125 mm 116 ( x ) 150 mm 117 [ e ] socket plain of the following size ( taking larger dimension ) 118 ( i ) 15 mm 119 ( ii ) 20 mm 120 ( iii ) 25 mm 121 ( iv ) 32 mm 122 ( v ) 40 mm 123 ( vi ) 50 mm 124 ( vii ) 65 mm 125 ( viii ) 80 mm 126 ( ix ) 100 mm 127 ( x ) 125 mm 128 ( xi ) 150 mm 129 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 130 ( i ) 20 mm 131 ( ii ) 25 mm 132 ( iii ) 32 mm 133 ( iv ) 40 mm 134 ( v ) 50 mm 135 ( vi ) 65 mm 136 ( vii ) 80 mm 137 ( viii ) 100 mm 138 ( ix ) 125 mm 139 ( x ) 150 mm 140 [ g ] union socket of the following sizes 141 ( i ) 15 mm 142 ( ii ) 20 mm 143 ( iii ) 25 mm 144 ( iv ) 32 mm 145 ( v ) 40 mm 146 ( vi ) 50 mm 147 ( vii ) 65 mm 148 ( viii ) 80 mm 149 ( ix ) 100 mm 150 ( x ) 125 mm 151 ( xi ) 150 mm 152 [ h ] plugs of the following sizes 153 ( i ) 15 mm 154 ( ii ) 20 mm 155 ( iii ) 25 mm 156 ( iv ) 32 mm 157 ( v ) 40 mm 158 ( vi ) 50 mm 159 ( vii ) 65 mm 160 ( viii ) 80 mm 161 ( ix ) 100 mm 162 ( x ) 125 mm 163 ( xi ) 150 mm 164 [ i ] jam nuts of the following sizes 165 ( i ) 15 mm 166 ( ii ) 20 mm 167 ( iii ) 25 mm 168 ( iv ) 32 mm 169 ( v ) 40 mm 170 ( vi ) 50 mm 171 ( vii ) 65 mm 172 ( viii ) 80 mm 173 ( ix ) 100 mm 174 ( x ) 125 mm 175 ( xi ) 150 mm 176 [ j ] g.i. nipple of the following sizes 177 ( i ) 15 mm dia x 100 mm long 178 ( ii ) 20 mm dia x 100 mm long 179 ( iii ) 25 mm dia x 100 mm long 180 ( iv ) 32mm dia x 100 mm long 181 ( v ) 40 mm dia x 100 mm long 182 ( vi ) 50 mm dia x 100 mm long 183 ( vii ) 65 mm dia x 100 mm long 184 ( viii ) 80 mm dia x 100 mm long 185 ( ix ) 100 mm dia x 100 mm long 186 [ k ] g.i. pipes midium ( tata mark ) or equivalent 187 ( i ) 15 mm dia 188 ( ii ) 20 mm dia 189 ( iii ) 25 mm dia 190 ( iv ) 32 mm dia 191 ( v ) 40 mm dia 192 ( vi ) 65 mm dia 193 mirrors 194 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 195 ( b ) do 450 mm x 300 mm do 196 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail 197 ( b ) do 450 mm x 125 mm do 198 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete 199 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 200 c.p. brass soap dish medium quality with screw andhinges etc. 201 c.p. liquid soap solution holder 202 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make 203 ( a ) 580 mm long 204 ( b ) 510 mm long 205 ( c ) 450 mm long 206 ( d ) 510 mm long white glazed fiber i.w.c 207 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make 208 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket 209 ( a ) 12.5 liters lowdown c.i. cistern 210 ( b ) 10.0 liters capacity p.v.c. low design cistern 211 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make 212 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 213 ( c ) black / white plastic seat for e.w.c do as above. 214 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size 215 ( b ) do squatting small 450 mm x 350 mm 216 ( c ) do squatting large 600 mm x 350 mm 217 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 218 ( e ) partition plate for urinal 25 x 13 size 219 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 220 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make 221 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make 222 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 223 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 224 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 225 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 226 drain board 227 ( a ) 600 mm x 450 mm ( 24 x 18 ) 228 ( b ) 525 mm x 450 mm ( 21 x 18 ) 229 h.c.i. pipes 230 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 231 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 232 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 233 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 234 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 235 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 236 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 237 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 238 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 239 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 240 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 241 ( l ) 150 mm dia single socket 3 0 with ear 242 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 243 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 244 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 245 ( p ) 150 mm dia single socket 2 0 with ear 246 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 247 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 248 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 249 ( t ) 150 mm dia single socket 250 h.c.i. fittings. 251 ( i ) plain bend of following size 252 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 253 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 254 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 255 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 256 ( ii ) bend with door with following size 257 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 258 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 259 ( c ) 100 mm dia do 5.5 kg 260 ( d ) 150 mm dia do 261 ( iii ) single junction with door of followings sizes. 262 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 263 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 264 ( c ) 100 mm dia do 9.50 kg 265 ( d ) 150 mm dia do 266 ( iv ) double junction with door of following sizes. 267 ( a ) 50 mm dia do 4.5 kg 268 ( b ) 80 mm dia do 7.00 kg 269 ( c ) 100 mm dia do 13.00 kg 270 ( d ) 150 mm dia do 271 ( v ) heel rest bend of following sizes 272 ( a ) 50 mm dia 273 ( b ) 80 mm dia 274 ( c ) 100 mm dia 275 ( d ) 150 mm dia 276 ( vi ) cowel of following sizes 277 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 278 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 279 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 280 ( d ) 150 mm dia do 281 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 282 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 283 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 284 ( x ) pass over 50 mm x 150 mm for 50 mm projection 285 ( xi ) do 100 mm x 150 mm for 100 mm projection 286 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 287 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 288 ( xiv ) h.c.i. offset 80 mm projection of the following size 289 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 290 ( b ) 80 mm dia do 3.50 kg 291 ( c ) 100 mm dia do 5.00 kg 292 ( d ) 150 mm dia do 293 ( xv ) h.c.i. socket of following sizes 294 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 295 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 296 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 297 ( d ) 150 mm dia ( weight without ear ) do 298 c.i. cover with frame for manhole and inspection chamber 299 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 300 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 301 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 302 c.i. bracket pair for w.h.b 303 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 304 ( b ) do for 12.5 liter cistern 305 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 306 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 307 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b 308 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 309 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 310 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 311 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b 312 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 313 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern 314 rubber inserttion 3 mm ( 1 / 8 ) thick 315 pig lead 316 yarn 317 rubber gasket for c.i pipe of good quality 318 ( a ) 80 mm 319 ( b ) 100 mm 320 ( c ) 125 mm 321 ( d ) 150 mm 322 ( e ) 200 mm 323 ( f ) 250 mm 324 ( g ) 300 mm 325 ( h ) 350 mm 326 ( i ) 400 mm 327 ( j ) 450 mm 328 ( k ) 500 mm 329 ( l ) 600 mm 330 ( m ) 700 mm 331 ( n ) 750 mm 332 ( o ) 800 mm 333 ( p ) 900 mm 334 ( q ) 1000 mm 335 ( r ) 1200 mm 336 cotton waste 337 asbestos suta ( gland packing ) 338 solvent cement 339 hydrocloric acid ( sepecific gravity 1.20 ) 340 cp & pvc fitting 341 ( i ) 32 mm dia c.p. waste 342 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 343 ( iii ) 40 mm dia c.p. waste 344 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 345 ( v 100 mm dia steel jali 346 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 347 ( vii ) 50 mm dia pvc pipe with coupling 348 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) 349 ( i ) pillar cock ( isi ) 350 ( ii ) pillar cock ( long neck ) 351 ( iii ) bib cock ( isi ) 352 ( iv ) bib cock ( long thread ) 353 ( v ) angular stop cock 354 ( vi ) angular stop cock ( long thread ) 355 ( vii ) concealed stop cock reduce ( isi ) 356 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 357 ( ix ) long body bib cock 358 ( x ) swan neck tap with left hand operating knob 359 ( xi ) central hole basin mixer ( best quality ) 360 ( xii ) wall mixer with telephonic shower arrangement 361 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 362 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 363 ( xv ) sink mixer with swinging casted spout 364 ( xvi ) sink cock with swinging casted spout 365 ( xvii ) 4 way diverter for concealed fittings 366 ( xviii ) pressure adjustable shower with revolving joint 367 ( xix ) telephone shower with flexible pipe 368 ( xx ) flush cock with wall flange ( 25 mm ) 369 ( xxi ) towel rail 24 370 ( xxii ) towel ring 371 ( xxiii ) soap dish 372 ( xxiv ) tumbler holder 373 ( xxv ) toilet paper holder 374 ( xxvi ) glass shelf 22 375 ( xxvii ) corner glass shelf with bracket 376 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 377 c.i special & pvc pipes 378 1. c.i double shocketted fittings bend such as bend, tee, taper, 379 ( a ) 80 200 mm 380 ( b ) 250 700 mm 381 ( c ) 700 1000 mm 382 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 383 ( a ) 80 200 mm 384 ( b ) 250 700 mm 385 ( b ) 250 700 mm 386 providing structural steel galvanised tubular hollow section work in trusses, other similar trussed purlins and members with all bracing , gusset plates etc as per detailed design and drawing or as directed by engineer in charge , including cutting fabricating , hoisting , erecting and fixing in position , making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & for structure ( plus ) providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns ( net wt. of components to be galv ) preferably tata structural section etc complete. 387 ( i ) ms square tube 388 75mmx75mmx4.80mm thick for 389 vertical column ( wt.@9.66kg / m ) 390 4nosx4.5m=18.00mx9.66kgp / m =173.88kg 391 ( ii ) ms square tube 392 75mmx75mmx4.80mm thick 393 support for top ( wt.@9.66kg / m ) 394 12nosx2.00m=24.0mx9.66kgp / m =231.84kg 395 ( iii ) square tube for bracing 396 40mmx40mmx3.20mm thick. 397 ( wt.@3.49kg / m ) 398 ( a ) for horizontal support beam 399 8nosx1.85m=14.80mx3.49kgp / m =51.65kg 400 8nosx2.4m=19.20mx3.49kgp / m =67.01kg 401 ( b ) for triangular support tube. 402 8nosx0.50m=4.00mx3.49kgp / m =13.96kg 403 ( c ) square tube 404 25mmx25mmx3.20mm thick. 405 for triangular ( wt.@1.98kg / m ) 406 8nosx0.65m=5.20mx1.98kgp / m=10.30kg 407 ( iv ) for railing square tube 25mmx25mmx3.20mm thick. 408 ( wt.@1.98kg / m ) 409 ( a ) horizontal beam 410 4x2=8nosx2.10m=16.80mx1.98kg / m=33.26kg 411 ( b ) vertical beam 412 4x4=16nosx0.55m=8.8mx1.98kg / m =17.424kg 413 ( v ) for laddersquare tube 25mmx25mmx2.50mm thick. 414 ( wt.@1.74kg / m ) 415 ( a ) vertical column 416 2nosx7m=14.00mx1.74kg / m =24.36kg 417 ( c ) steps 418 squaretube25mmx25mmx3.20thick 419 ( wt.@1.98kg / m 420 22nosx0.45m=9.9mx1.98kg / m=19.60kg 421 ( vi ) m.s. plate 10mm thick 422 ( wt.@78.50kg / sqm ) 423 ( a ) base plate for column –4x1=4nos 424 top & bottom =8nos 425 total=12nos 426 12nosx0.250mx0.250 =0.75m2 427 0.75m2x78.50kg / m2=58.875kg 428 ( b ) stiffener plate at bottom column 429 support ( size 0.225x0.075 ) x10mm thick 430 1x4x4=16nosx0.225x0.075=0.27m2 431 =0.27m2x78.50kg / m2 =21.20kg 432 ( vii ) m.s. plate 6mm thick 433 ( wt.@47.10kg / sqm ) 434 ( a ) for horizontal & diagonal 435 beam connection–4x2=8nos 436 16x0.25x0.06x0.006x7850=11.30kg 437 8x0.15x0.04x0.006x7850=2.26kg 438 ( b ) stiffener plate for top angular 439 support 440 16nosx0.20x0.060x0.006x7850=9.04kg 441 8x0.15x0.06x0.006x7850=3.39kg 442 ( viii ) m.s. plate 3mm thick 443 ( wt.@15.70kg / sqm ) 444 2.1x2.1x0.003x7850 =103.86kg 445 ( ix ) nut bolt 16mm dia length 450mm ( wt.@1.112kg each ) 446 16nosx1.112kg=17.80kg 447 ( x ) nut bolts of various sizes for fixing 448 of structure ( lump sum ) =22.00kg 449 total=893.01kg 450 weight after galvanising @ 4% = 928.73kg 451 steel structure for solor panel 452 60mmx60mmx3.2mm size square tube 453 3.342mx2.00nosx5.62kg / m=37.56kg 454 2.50mx2.0mx 2.0nos x5.62 kg / m=28.10 kg 455 25 x25 x 3.20mm size square tube 456 2.019m x 8nos x 1.98 kg / m =31.98kg 457 0.50m x 20nos x 1.98kg / m = 19.80kg 458 75 x 75 x 4.8 mm size square tube 459 2.47 m x 4nos x 9.66kg / m = 95.44kg 460 75 x 40mm size is lc 461 3.05m x 2 x 2.61kg / m = 15.92kg 462 6mm thick ms plate 463 0.2m x 0.1m x 8nos x 47.10kg / m2 = 7.54kg 464 nut bolt 465 l.s.2kg 466 total: 238.34kg 467 weight after galvanising @ 4% = 247.87kg 468 grand total: 928.73 + 247.87= 1176.60kg 469 information board for iec 470 providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by engineer in charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete ( mjp 2019 2020 sec f item 6 ) 471 ( i ) square tube 472 25mmx25mmx3.2mm thick 473 ( wt.@1.98kg / m ) 474 2nosx1.50m=3.00m=3.00mx1.98kg / m=5.94kg 475 ( ii ) square tube 476 25mmx25mmx3.2mm thick 477 ( wt.@1.98kg / m ) 478 3nosx1.20m=3.60m=3.60mx1.98kg / m=7.13kg 479 ( iii ) m.s. sheet 1mm thick. 480 ( wt.@7.85kg / m2 ) 481 1nosx1.50mx1.20m=1.80m2 482 =1.80m2x7.85kgp / m2=14.13kg 483 total=27.20kg 484 providing structural steel galvanisedsqure pipe section work in trusses, other similar trussed purlins and members with all bracing , gusset plates etc as per detailed design and drawing or as directed by engineer in charge , including cutting fabricating , hoisting , erecting and fixing in position , making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coat of all oil painting & for structure ( plus ) providing and applying materials &labour for hot dip galvanizing of above structure including transportation for galvanizing minimum thickness 80microns ( net wt. of components to be galv ) preferably tata structural section etc complete. 485 ( i ) leg pipe 91.5x91.5x4.8mm thick ( square pipe ) 486 4nos.x6mx13.7kg / m=328.80 kg 487 ( ii ) base plate 300mmx12mm thick ( plate ) 488 4nos.x0.3mx28.26kg / m=33.91kg 489 ( iii ) stiffener 100mmx10mm of thick ( flat ) 490 32nosx0.15m.x7.85kg / m=18.84 kg 491 ( iv ) top flange 300mmx10mm of thick ( plate ) 492 4nos.x0.3mx23.55kg / m=28.26 kg 493 ( v ) frame base plate 300mmx8mm of thick ( plate ) 494 4nosx0.3m.x18.84kg / m=22.61kg 495 ( vi ) upper stiffener 40mmx6mm of thick ( flat ) 496 16nos.x0.1mx1.9kg / m=3.04kg 497 ( vii ) a. gusset plate on main leg 184mmx6mm of thick ( plate ) 498 32nos.x0.225mx8.7kg / m=62.64kg 499 b. gusset plate on horizontal bracing 178mmx6mm of thick ( plate ) 500 16nos.x0.244mx8.4kg / m=32.79kg 501 ( viii ) horizontal bracing 65mmx65mmx6mm of thick ( angle ) 502 16nos.x1.324mx4.9kg / m=103.80kg 503 ( ix ) diagonal bracing 50mmx50mmx6mm of thick ( angle ) 504 32nos.x1.386mx3.8kg / m=168.54kg 505 ( x ) upper stiffner 100mmx10mm of thick ( flat ) 506 16nos.x0.15mx7.85kg / m=9.42kg 507 ( x ) a. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 508 2nos.x2.5mx9.66kg / m=48.30kg 509 b. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 510 4nos.x1.363mx9.66kg / m=52.67kg 511 c. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 512 4nos.x0.46mx9.66kg / m=17.77kg 513 d. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 514 2nos.x9.66kg / m=5.78kg 515 e. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 516 0.4965mx0.299mx16nos.x9.66kg / m=76.74kg 517 f. base of tank 72mmx72mmx4.8mm of thick ( square pipe ) 518 gusset plate 244x178x6mm thick 4 nos 519 4nos.x0.425mx9.66kg / m=16.42kg 520 ( xi ) a. ladder joint cliet 65mmx65mmx5mm of thick ( angle ) 521 2nos.x0.05mx4.9kg / m=0.49kg 522 b. ladder 35mmx35mmx5mm of thick ( angle ) 523 4nos.x3mx2.7kg / m=32.40kg 524 c. horizontal support angle 525 40x40x5mm thick 300mm long 20 nos 526 d. ladder 35mmx35mmx5mm of thick ( angle ) 527 2nos.x2.05mx2.7kg / m=11.07kg 528 e. horizontal support angle 529 40x40x5mm thick 300mm7 nos 530 horizontal support angle 531 f.ladder joint cliet 40mmx40mmx5mm of thick ( angle ) 532 2nos.x0.166mx3kg / m=1.00kg 533 ( xii ) a.frame railing pipe 25mmx25mmx2.8mm of thick ( square pipe ) 534 4nos.x2.05mx2.2kg / m=18.04kg 535 b.frame railing pipe 25mmx25mmx2.8mm of thick ( square pipe ) 536 12nos.x0.775mx2.2kg / m=20.46kg 537 ( xiii ) g.i. sheet 2500mmx1250mmx3mm of thick 538 2nos.x2.5mx29.5kg / m=147.50kg 539 ( xiv ) foundation bolt 20mm of thick ( m20 ) 540 16nos.x1.2mx2.47kg / m=47.42kg 541 total wegit 1414.78 kg 542 weight after galvanising @ 4% ( 1414.78 +30 = 1444.78kg ) 543 ( xv ) hardware ( l.s. ) 544 total 545 steel structure for solor panel 546 60mmx60mmx3.2mm size square tube 547 3.342mx2.00nosx5.62kg / m=37.56kg 548 2.50mx2.0mx 2.0nos x5.62 kg / m=28.10 kg 549 25 x25 x 3.20mm size square tube 550 2.019m x 8nos x 1.98 kg / m =31.98kg 551 0.50m x 20nos x 1.98kg / m = 19.80kg 552 75 x 75 x 4.8 mm size square tube 553 2.47 m x 4nos x 9.66kg / m = 95.44kg 554 75 x 40mm size is lc 555 3.05m x 2 x 2.61kg / m = 15.92kg 556 6mm thick ms plate 557 0.2m x 0.1m x 8nos x 47.10kg / m2 = 7.54kg 558 nut bolt 559 l.s.2kg 560 total: 238.34kg 561 weight after galvanising @ 4%=247.87kg 562 grand total: 1444.78 + 247.87= 1692.65kg 563 information board for iec 564 providing structural steel work in trusses other similar trussed purlins and members with bracing gusset plates etc as per detailed design and drawing or as directed by engineer in charge including cutting fabricating hoisting erecting and fixing in position making reverted bolted welded connections one coat of anticorrosive paint and over it two coats of oil painting etc complete ( mjp 2019 2020 sec f item 6 ) 565 ( i ) square tube 566 25mmx25mmx3.2mm thick 567 ( wt.@1.98kg / m ) 568 2nosx1.50m=3.00m=3.00mx1.98kg / m=5.94kg 569 ( ii ) square tube 570 25mmx25mmx3.2mm thick 571 ( wt.@1.98kg / m ) 572 3nosx1.20m=3.60m=3.60mx1.98kg / m=7.13kg 573 ( iii ) m.s. sheet 1mm thick. 574 ( wt.@7.85kg / m2 ) 575 1nosx1.50mx1.20m=1.80m2 576 =1.80m2x7.85kgp / m2=14.13kg 577 total=27.20kg...

Drinking Water And Sanitation Department - Jharkhand

32235694 procurement of rate of materials 1 m079 polythene water storage tank of isi mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system 2 m193gi pipe 50 mm dia ( tata or equivalent make ) 3 m337jute 4 m922g.m. ferrules 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 m923stop cocks 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 m924g.m. full way valve 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 m925g.m. non return valve vertical 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 m926g.m. non return valve horizontal 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 m927 cocks 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 m928chromium plated brass fittings 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 m929connection pipe 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 m930g.i. fittings ( conforming to i.s. 1879 ) isi marked 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 m931mirrors 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 m932 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail 194 ( b ) do 450 mm x 125 mm do 195 m933 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 m934c.p. brass soap dish medium quality with screw andhinges etc. 198 m935c.p. liquid soap solution holder 199 m936vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 m937pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make 205 m93815 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket 206 m939 ( a ) 12.5 liters lowdown c.i. cistern 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 m940 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 m941 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 m942white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make 218 m943white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 m944drain board 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 m945h.c.i. pipes 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 m946h.c.i. fittings. 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 m947c.i. cover with frame for manhole and inspection chamber 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 m948c.i. bracket pair for w.h.b 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 m949 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 m950 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 m95132 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern 311 m952rubber inserttion 3 mm ( 1 / 8 ) thick 312 m953pig lead 313 m954yarn 314 m955rubber gasket for c.i pipe of good quality 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 m956cotton waste 334 m957asbestos suta ( gland packing ) 335 m958solvent cement 336 m959hydrocloric acid ( sepecific gravity 1.20 ) 337 m960cp & pvc fitting 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 m961special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 m962c.i special & pvc pipes 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 m1038trenchless 385 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 386 from 900 mm to 1000 mm dia 387 in soft soil 388 in hard soil 389 in sandy soil 390 in stone soil 391 from 1000 mm to 1200 mm dia 392 in soft soil 393 in hard soil 394 in sandy soil 395 in stone soil 396 above 1200 mm to 1500 mm dia 397 in soft soil 398 in hard soil 399 in sandy soil 400 in stone soil 401 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 402 upto 300 mm dia 403 in soft soil 404 in hard soil 405 in sandy soil 406 in stone soil 407 above300 mm to 450 mm dia 408 in soft soil 409 in hard soil 410 in sandy soil 411 in stone soil 412 above 450 mm to 600 mm dia 413 in soft soil 414 in hard soil 415 in sandy soil 416 in stone soil 417 above 600 mm to 900 mm dia 418 in soft soil 419 in hard soil 420 in sandy soil 421 in stone soil 422 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 423 upto 300 mm dia 424 in soft soil 425 in hard soil 426 in sandy soil 427 in stone soil 428 above300 mm to 450 mm dia 429 in soft soil 430 in hard soil 431 in sandy soil 432 in stone soil 433 above 450 mm to 600 mm dia 434 in soft soil 435 in hard soil 436 in sandy soil 437 in stone soil 438 above 600 mm to 900 mm dia 439 in soft soil 440 in hard soil 441 in sandy soil 442 in stone soil 443 m1039providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) 444 without byepass arrangement pn 1 445 50 mm 446 65 mm 447 80 mm 448 100 mm 449 125 mm 450 150 mm 451 200 mm 452 250 mm 453 300 mm 454 350 mm 455 400 mm 456 450 mm 457 500 mm 458 600 mm 459 700 mm 460 750 mm 461 800 mm 462 900 mm 463 1000 mm 464 1100 mm 465 1200 mm 466 with byepass arrangement pn 1 467 50 mm 468 65 mm 469 80 mm 470 100 mm 471 125 mm 472 150 mm 473 200 mm 474 250 mm 475 300 mm 476 350 mm 477 400 mm 478 450 mm 479 500 mm 480 600 mm 481 700 mm 482 750 mm 483 800 mm 484 900 mm 485 1000 mm 486 1100 mm 487 1200 mm 488 without byepass arrangement pn 1.6 489 50 mm 490 65 mm 491 80 mm 492 100 mm 493 125 mm 494 150 mm 495 200 mm 496 250 mm 497 300 mm 498 350 mm 499 400 mm 500 450 mm 501 500 mm 502 600 mm 503 with byepass arrangement pn 1.6 504 50 mm 505 65 mm 506 80 mm 507 100 mm 508 125 mm 509 150 mm 510 200 mm 511 250 mm 512 300 mm 513 350 mm 514 400 mm 515 450 mm 516 500 mm 517 600 mm 518 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 519 with byepass arrangement pn 1 520 50 mm 521 65 mm 522 80 mm 523 100 mm 524 125 mm 525 150 mm 526 200 mm 527 250 mm 528 300 mm 529 350 mm 530 400 mm 531 450 mm 532 500 mm 533 600 mm 534 700mm 535 750 mm 536 800 mm 537 900 mm 538 1000 mm 539 1100 mm 540 1200mm 541 without byepass arrangement pn 1 542 50 mm 543 65 mm 544 80 mm 545 100 mm 546 125 mm 547 150 mm 548 200 mm 549 250 mm 550 300 mm 551 350 mm 552 400 mm 553 450 mm 554 500 mm 555 600 mm 556 700mm 557 750 mm 558 800 mm 559 900 mm 560 1000 mm 561 1100 mm 562 1200mm 563 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 564 without byepass arrangement pn 1.6 565 50 mm 566 65 mm 567 80 mm 568 100 mm 569 125 mm 570 150 mm 571 200 mm 572 250 mm 573 300 mm 574 350 mm 575 400 mm 576 450 mm 577 500 mm 578 600 mm 579 700mm 580 750 mm 581 800 mm 582 900 mm 583 1000 mm 584 1100 mm 585 1200mm 586 with byepass arrangement pn 1.6 587 50 mm 588 65 mm 589 80 mm 590 100 mm 591 125 mm 592 150 mm 593 200 mm 594 250 mm 595 300 mm 596 350 mm 597 400 mm 598 450 mm 599 500 mm 600 600 mm...

Drinking Water And Sanitation Department - Jharkhand

32226054 e quotation for rate of materials for schedule rate jharkhand under d w and s division, deoghar e quotation for rate of materials for schedule rate jharkhand under d w and s division, deoghar , polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) , gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) , jute ( m337 ) , g.m. ferrules ( m922 ) , ( i ) 8 mm dia wt. not less than 400 gms , ( ii ) 10 mm dia wt. not less than 400 gms , ( iii ) 15 mm dia wt. not less than 400 gms , ( iv ) 20 mm dia wt. not less than 600 gms , ( v ) 25 mm dia wt. not less than 900 gms , stop cocks ( m923 ) , ( i ) 15 mm brass stop cock wt. not less than 300 gms , ( ii ) 20 mm brass stop cock wt. not less than 400 gms , ( iii ) 25 mm brass stop cock wt. not less than 575 gms , ( iv ) 32 mm brass stop cock wt. not less than 850 gms , ( v ) 40 mm brass stop cock wt. not less than 1.15 kg , ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg , ( vii ) 15 mm dia c.i. body brass working part stop cock. , ( viii ) 20 mm dia c.i. body brass working part stop cock. , ( ix ) 25 mm dia c.i. body brass working part stop cock. , g.m. full way valve ( m924 ) , ( i ) 15 mm dia wt. not less than 300 gms without wheel , ( ii ) 20 mm dia wt. not less than 400 gms without wheel , ( iii ) 25 mm dia wt. not less than 500 gms without wheel , ( iv ) 32 mm dia wt. not less than 700 gms without wheel , ( v ) 40 mm dia wt. not less than 1.0 kg without wheel , ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel , ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel , ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel , g.m. non return valve verticle ( m925 ) , ( i ) 15 mm dia wt. not less than 150 gms , ( ii ) 20 mm dia wt. not less than 250 gms , ( iii ) 25 mm dia wt. not less than 375 gms , ( iv ) 32 mm dia wt. not less than 600 gms , ( v ) 40 mm dia wt. not less than 700 gms , ( vi ) 50 mm dia wt. not less than 1.0 kg , ( vii ) 65 mm dia wt. not less than 1.20 kg , ( viii ) 80 mm dia wt. not less than 1.50 kg , ( ix ) 100 mm dia wt. not less than 1.80 kg , g.m. non return valve horizontal ( m926 ) , ( i ) 15 mm dia wt. not less than 150 gms , ( ii ) 20 mm dia wt. not less than 250 gms , ( iii ) 25 mm dia wt. not less than 375 gms , ( iv ) 32 mm dia wt. not less than 600 gms , ( v ) 40 mm dia wt. not less than 700 gms , ( vi ) 50 mm dia wt. not less than 1.0 kg , ( vii ) 65 mm dia wt. not less than 1.20 kg , ( viii ) 80 mm dia wt. not less than 1.50 kg , ( ix ) 100 mm dia wt. not less than 1.80 kg , cocks ( m927 ) , ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms , ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms , ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms , ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms , ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms , ( vi ) 15 mm c.i. plug cock ordinary , ( vii ) 15 mm c.i. push cock ordinary , chromium plated brass fittings ( m928 ) , ( i ) c.p. shower rose 100 mm dia , ( ii ) c.p. shower rose 125 mm dia , ( iii ) p.v.c. shower rose 150 mm dia , ( iv ) p.v.c shower rose 125 mm dia , connection pipe ( m929 ) , ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. , ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. , ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. , ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. , g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) , [ a ] g.i. bend , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ b ] elbow of the following sizes , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ c ] tee plain of the following sizes , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ d ] reducing tee plain of the following sizes ( taking larger dimension ) , ( i ) 20 mm , ( ii ) 25 mm , ( iii ) 32 mm , ( iv ) 40 mm , ( v ) 50 mm , ( vi ) 65 mm , ( vii ) 80 mm , ( viii ) 100 mm , ( ix ) 125 mm , ( x ) 150 mm , [ e ] socket plain of the following size ( taking larger dimension ) , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ f ] reducing socket plain of the following sizes ( taking larger dimension ) , ( i ) 20 mm , ( ii ) 25 mm , ( iii ) 32 mm , ( iv ) 40 mm , ( v ) 50 mm , ( vi ) 65 mm , ( vii ) 80 mm , ( viii ) 100 mm , ( ix ) 125 mm , ( x ) 150 mm , [ g ] union socket of the following sizes , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ h ] plugs of the following sizes , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ i ] jam nuts of the following sizes , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ( vii ) 65 mm , ( viii ) 80 mm , ( ix ) 100 mm , ( x ) 125 mm , ( xi ) 150 mm , [ j ] g.i. nipple of the following sizes , ( i ) 15 mm dia x 100 mm long , ( ii ) 20 mm dia x 100 mm long , ( iii ) 25 mm dia x 100 mm long , ( iv ) 32mm dia x 100 mm long , ( v ) 40 mm dia x 100 mm long , ( vi ) 50 mm dia x 100 mm long , ( vii ) 65 mm dia x 100 mm long , ( viii ) 80 mm dia x 100 mm long , ( ix ) 100 mm dia x 100 mm long , [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality , ( i ) 15 mm dia , ( ii ) 20 mm dia , ( iii ) 25 mm dia , ( iv ) 32 mm dia , ( v ) 40 mm dia , ( vii ) 65 mm dia , mirrors ( m931 ) , ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror , ( b ) do 450 mm x 300 mm do , ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) , ( b ) do 450 mm x 125 mm do , ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) , ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets , c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) , c.p. liquid soap solution holder ( m935 ) , vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) , ( a ) 580 mm long , ( b ) 510 mm long , ( c ) 450 mm long , ( d ) 510 mm long white glazed fiber i.w.c , pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) , 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) , ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) , ( b ) 10.0 liters capacity p.v.c. low design cistern , ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) , ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make , ( c ) black / white plastic seat for e.w.c do as above. , ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) , ( b ) do squatting small 450 mm x 350 mm , ( c ) do squatting large 600 mm x 350 mm , ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make , ( e ) partition plate for urinal 25 x 13 size , ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings , white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) , white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) , ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) , ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) , ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) , ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) , drain board. ( m944 ) , ( a ) 600 mm x 450 mm ( 24 x 18 ) , ( b ) 525 mm x 450 mm ( 21 x 18 ) , h.c.i. pipes ( m945 ) , ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) , ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) , ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) , ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) , ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) , ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) , ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) , ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) , ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) , ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) , ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) , ( l ) 150 mm dia single socket 3 0 with ear , ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) , ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) , ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) , ( p ) 150 mm dia single socket 2 0 with ear , ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) , ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) , ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) , ( t ) 150 mm dia single socket , h.c.i. fittings. ( m946 ) , ( i ) plain bend of following size , ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) , ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) , ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) , ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) , ( ii ) bend with door with following size , ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) , ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) , ( c ) 100 mm dia do 5.5 kg , ( d ) 150 mm dia do , ( iii ) single junction with door of followings sizes. , ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) , ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) , ( c ) 100 mm dia do 9.50 kg , ( d ) 150 mm dia do , ( iv ) double junction with door of following sizes. , ( a ) 50 mm dia do 4.5 kg , ( b ) 80 mm dia do 7.00 kg , ( c ) 100 mm dia do 13.00 kg , ( d ) 150 mm dia do , ( v ) heel rest bend of following sizes , ( a ) 50 mm dia , ( b ) 80 mm dia , ( c ) 100 mm dia , ( d ) 150 mm dia , ( vi ) cowel of following sizes , ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) , ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) , ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) , ( d ) 150 mm dia do , ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg , ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg , ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg , ( x ) pass over 50 mm x 150 mm for 50 mm projection , ( xi ) do 100 mm x 150 mm for 100 mm projection , ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg , ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg , ( xiv ) h.c.i. offset 80 mm projection of the following size , ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg , ( b ) 80 mm dia do 3.50 kg , ( c ) 100 mm dia do 5.00 kg , ( d ) 150 mm dia do , ( xv ) h.c.i. socket of following sizes , ( a ) 50 mm dia ( weight without ear ) 1.50 kg , ( b ) 80 mm dia ( weight without ear ) 3.00 kg , ( c ) 100 mm dia ( weight without ear ) 4.50 kg , ( d ) 150 mm dia ( weight without ear ) do , c.i. cover with frame for manhole and inspection chamber. ( m947 ) , ( a ) 600 mm x 450 mm size ( wt. 39 kg ) , ( b ) 600 mm x 450 mm size ( wt. 25 kg ) , ( c ) 500 mm x 450 mm size ( wt. 25 kg ) , c.i. bracket pair for w.h.b. ( m948 ) , ( a ) 550 mm x 400 mm size ( 22 x 16 ) , ( b ) do for 12.5 liter cistern , ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink , ( d ) 40 mm x 60 mm ms plate bracket for sink as above , ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) , ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink , ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal , ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal , ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) , ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b , 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) , rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) , pig lead ( m953 ) , yarn ( m954 ) , rubber gasket for c.i pipe of good quality ( m955 ) , ( a ) 80 mm , ( b ) 100 mm , ( c ) 125 mm , ( d ) 150 mm , ( e ) 200 mm , ( f ) 250 mm , ( g ) 300 mm , ( h ) 350 mm , ( i ) 400 mm , ( j ) 450 mm , ( k ) 500 mm , ( l ) 600 mm , ( m ) 700 mm , ( n ) 750 mm , ( o ) 800 mm , ( p ) 900 mm , ( q ) 1000 mm , ( r ) 1200 mm , cotton waste ( m956 ) , asbestos suta ( gland packing ) ( m957 ) , solvent cement ( m958 ) , hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) , cp & pvc fitting ( m960 ) , ( i ) 32 mm dia c.p. waste , ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling , ( iii ) 40 mm dia c.p. waste , ( iv 40 mm dia pvc waste pipe 750 mm long with coupling , ( v 100 mm dia steel jali , ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) , ( vii ) 50 mm dia pvc pipe with coupling , special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) , ( i ) pillar cock ( isi ) , ( ii ) pillar cock ( long neck ) , ( iii ) bib cock ( isi ) , ( iv ) bib cock ( long thread ) , ( v ) angular stop cock , ( vi ) angular stop cock ( long thread ) , ( vii ) concealed stop cock reduce ( isi ) , ( viii ) concealed stop cock heavy duty extra adjustable wall flange , ( ix ) long body bib cock , ( x ) swan neck tap with left hand operating knob , ( xi ) central hole basin mixer ( best quality ) , ( xii ) wall mixer with telephonic shower arrangement , ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange , ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange , ( xv ) sink mixer with swinging casted spout , ( xvi ) sink cock with swinging casted spout , ( xvii ) 4 way diverter for concealed fittings , ( xviii ) pressure adjustable shower with revolving joint , ( xix ) telephone shower with flexible pipe , ( xx ) flush cock with wall flange ( 25 mm ) , ( xxi ) towel rail 24 , ( xxii ) towel ring , ( xxiii ) soap dish , ( xxiv ) tumbler holder , ( xxv ) toilet paper holder , ( xxvi ) glass shelf 22 , ( xxvii ) corner glass shelf with bracket , ( xxviii ) flush valve complete with 32 mm size controlcock & flange , c.i special & pvc pipes ( m962 ) , 1. c.i double shocketted fittings bend such as bend, tee, taper, , ( a ) 80 200 mm , ( b ) 250 700 mm , ( c ) 700 1000 mm , 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc , ( a ) 80 200 mm , ( b ) 250 700 mm , ( c ) 700 1000 mm , spare parts of hand pump , basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) , providing and supplying of isi standarddi specials & fitting with sealing rubber gasket of sbr, complete with cast iron follower gland & ms nut bolts coated or otherwise protected from rusting and suitable for di pipescomplete as per is 9523 class k 12 ( ex factoryrates ) inspection charge transportation , cp extra. ( m1027 ) , socketed , 100 150 mm dia , 200 300mm dia , 350 450mm dia , 500 600mm dia , 700 mm dia , 800 mm dia , 900 mm dia , 1000 mm dia , 1100 mm dia , 1200 mm dia , flanged , 100 150 mm dia , 200 300 mm dia , 350 450mm dia , 500 600mm dia , 700 mm dia , 800 mm dia , 900 mm dia , 1000 mm dia , 1100 mm dia , 1200 mm dia , rcc esr ( m1030 ) , designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. , notes , the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) , the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. , for design having more than 6 columns, suitable bracing is obligatory. , plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed , irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. , these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. , staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 , these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. , all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. , 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. , the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . , for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. , below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. , the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. , the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : , 12 to 16 m staging 2% per metre , 16 to 20 m staging 3% per metre , 20 m and above 4% per metre , for 17 m staging height, percentage calculation will be like below : , 12 to 16 m 4 x 2 = 8% , 16 & 17 m 1 x 3% = 3% total = 11% , for 21 m staging height, percentage calculation will be like below : , 12 to 16 m 4 x 2 = 8% , 16 to 20 m 4 x 3% = 12% , 20& 21 m 1 x 4% = 4% total = 24% , following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . , notes , conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. , conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. , rates for rcc esrs , upto 25, 000 litres , cost of 25, 000 litres capacity , add for capacity above 25, 000 upto 50, 000 litres , cost of 50, 000 litres capacity , add for capacity above 50, 000 upto 75, 000 litres , cost of 75, 000 litres capacity , add for capacity above 75, 000 upto 1, 00, 000 litres , cost of 1, 00, 000 litres capacity , add for capacity above 1, 00, 000 upto 1, 50, 000 litres , cost of 1, 50, 000 litres capacity , add for capacity above 1, 50, 000 upto 2, 00, 000 litres , cost of 2, 00, 000 litres capacity , add for capacity above 2, 00, 000 upto 2, 50, 000 litres , cost of 2, 50, 000 litres capacity , add for capacity above 2, 50, 000 upto 3, 00, 000 litres , cost of 3, 00, 000 litres capacity , add for capacity above 3, 00, 000 upto 4, 00, 000 litres , cost of 4, 00, 000 litres capacity , add for capacity above 4, 00, 000 upto 5, 00, 000 litres , cost of 5, 00, 000 litres capacity , add for capacity above 5, 00, 000 upto 7, 50, 000 litres , cost of 7, 50, 000 litres capacity , add for capacity above 7, 50, 000 upto 10, 00, 000 litres , cost of 10, 00, 000 litres capacity , add for capacity above 10, 00, 000 upto 15, 00, 000 litres , cost of 15, 00, 000 litres capacity , add for capacity above 15, 00, 000 upto 20, 00, 000 litres , cost of 20, 00, 000 litres capacity , rcc gsr and sump ( m1031 ) , designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. , anti –termite treatment shall be given for under ground portion of the structure. , notes , the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) , only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. , entire structure shall be in m 300 only. , the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. , the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. , the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. , g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. , for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. , cost of pump house is not included in these rates. , above rates are applicable for seismic zones 2, 3 and 4. , 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. , 10% shall be added for sump if over head pump house is proposed. , note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. , rates for rcc gsrs and sumps , upto 25, 000 litres , cost of 25, 000 litres capacity , add for capacity above 25, 000 upto 50, 000 litres , cost of 50, 000 litres capacity , add for capacity above 50, 000 upto 75, 000 litres , cost of 75, 000 litres capacity , add for capacity above 75, 000 upto 1, 00, 000 litres , cost of 1, 00, 000 litres capacity , add for capacity above 1, 00, 000 upto 1, 50, 000 litres , cost of 1, 50, 000 litres capacity , add for capacity above 1, 50, 000 upto 2, 00, 000 litres , cost of 2, 00, 000 litres capacity , add for capacity above 2, 00, 000 upto 3, 00, 000 litres , cost of 3, 00, 000 litres capacity , add for capacity above 3, 00, 000 upto 5, 00, 000 litres , cost of 5, 00, 000 litres capacity , add for capacity above 5, 00, 000 upto 10, 00, 000 litres , cost of 10, 00, 000 litres capacity , addforcapacityabove10, 00, 000upto15, 00, 000 litres , cost of 15, 00, 000 litres capacity , add for capacity above 15, 00, 000 litres , note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. , unconventionalwater treatment plant ( m1032 ) , designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. , aeration fountain , inlet arrangements , mixing channel with ventury flume and flow measuring arrangement , inlet channel , flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes , tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance , rapid sand gravity filters all valve shall be glandless. , filter house , chemical house , alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. , 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. , tcl solution tank with mixing, carrying and dosing arrangement with piping. , bypass arrangement , external and internal electrification , laboratory equipments , wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. , wash water pumps with 100% standby , air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. , pure water sump of capacity equal to 1 hourpumping capacity. , pure water pump house over the sump / by the side of sump. , drainage arrangements , alum store , sanitary block with necessary water supply and drainage arrangements and internalwbm roads. , these rates are applicable for seismic zones 2, 3 and 4. , rates given below are inclusive of uplift pressure if any and dewatering during the entire work. , all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. , unconventional treatment plants less than 1 mld capacity shall not be constructed. , all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . , note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. , unconventional water treatment plant , fixed cost for 1 mld , add for capacity above 1 mld upto 2 mld , cost of 2 mld treatment plant , add for capacity above 2 mld upto 3 mld , cost of 3 mld treatment plant , conventionalwater treatment plant ( m1033 ) , designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . , aeration fountain plan are a not less than 0.625 square metre per mld , ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) , flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. , flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. , clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. , rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. , filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. , wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. , wash water pumps capacity to fill water tank in 1 hour with 100% standby. , air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . , chemical house in two storeys , ground floor to accommodate 7 days alum requirement and sundry storage. , first floor to accommodate alum and lime tanks.etc. , solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. , pure water sump and sump house. , capacity of sump – one hour of designed flow. , pump house pump house of required size over the sump or by the side. , store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. , vacuum feed type chlorinators make tobe approved by mjp. , conforming to i.s. 10533 a part ii 1983 , rate for withdrawal , temperature kg. of chlorine discharge degree c per day ( cylinders ) , 45 67 tonnes , 10 6.359.50 110 , 15 10.75 16.10130 , 20 14.50 21.24254 , 27&above18.70 28.12315 , chlorinator equipment and container room to conform to i.s. 10553 part i 1983. , 100% standby shall be provided. , by pass arrangements c.i. or m.s. pipes. , disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe , for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete , drainage arrangements – rcc pipes up to plot boundary. , electrical installation – both internal and external including entire plant area. , laboratory equipment –as per requirement ( to be specified during tendering ) . , sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. , administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. , rates given below are inclusive of up lift pressure if any and dewatering during entire work. , all pipes condutes channels with20%overloading , these rates are applicable for seismic zones 2, 3 and 4. , all rcc structures shall be constructed in m 300. , note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . , conventional water treatment plant , above3 mld to upto 5 mld , cost of 5 mld treatment plant , add for capacity above 5mld upto 10 mld , cost of 10 mld treatment plant , add for capacity above 10 mld upto20 mld , cost of 20 mld treatment plant , add for capacity above 20 mld upto 50 mld , cost of 50 mld treatment plant , add for capacityabove 50 mld upto 100 mld , cost of 100 mld treatment plant , add for capacity above 100 mld , gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) , 300 mm dia for gpt , 400 mm dia for hygpt , hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) , from 0 50 meter , from 51 125 meter , dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) , drillig upto 30 mtr depth below g. l. in rural area , drilling beyond 31 mtr upto 60 mtr below g. l. in rural area , trenchless ( m1038 ) , installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) , from 900 mm to 1000 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , from 1000 mm to 1200 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above 1200 mm to 1500 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) , upto 300 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above300 mm to 450 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above 450 mm to 600 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above 600 mm to 900 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) , upto 300 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above300 mm to 450 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above 450 mm to 600 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , above 600 mm to 900 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) , without byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700 mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200 mm , with byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700 mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200 mm , without byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , with byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . , with byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , without byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . , without byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , with byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . ( m1040 ) , dia 06 inch ( 150 mm ) , id 153 mm od 167 mm , screen thickness 07 mm , slot 1.00 mm , moc lowcarbon galvenised steel , length 5 mtr. , dia 08 inch ( 200 mm ) , id 205 mm od 221mm , screen thickness 08 mm , slot 1.00 mm , moc lowcarbon galvenised steel , length 5 mtr. , dia 10 inch ( 250 mm ) , id 256 mm od 276mm , screen thickness 10 mm , slot 1.00 mm , moc lowcarbon galvenised steel , length 5 mtr. , dia 12 inch ( 300 mm ) , id 306 mm od 326 mm , screen thickness 10 mm , slot 1.00 mm , moc lowcarbon galvenised steel , length 5 mtr. , dia 14 inch ( 350 mm ) , id 338 mm od 363 mm , screen thickness 12.5 mm , slot 1.00 mm , moc lowcarbon galvenised steel , length 5 mtr. , supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) , supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) , supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) , supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) , supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) , supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) , supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) , supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) , supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) , supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) , supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) , supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) , supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) , design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) , packaged lamella clarified type wtp with mgf capacity in mld. , ( i ) 0.2 , ( ii ) 0.3 , ( iii ) 0.4 , ( iv ) 0.5 , ( v ) 0.6 , pvc schedule 80 pipe 3.00m length , application : corrosion resistant pressure pipe, ips sizes 1 / 4 through 24, for use at temperatures up to and including 140°f. pressure rating ( 120 psi to 1230 psi ) varies with schedule, pipe size, and temperature. generally resistant to most acids, bases, salts, aliphatic solutions, oxidants, and halogens. chemical resistance data is available and should be referenced for proper material selection. pipe exhibits excellent physical properties and flammability characteristics. typical allications include: chemical processing, plating, high purity applications, potable water systems, water and wastewater treatment, drainage, irrigation, agricultural, and other applications involving corrosive fluid transfer. , scope : this specification outlines minimum manufacturing requirements for polyviny chloride ( pvc ) schedule 80 iron pipe size ( ips ) pressure pipe. this pipe is intended for use in applications where the fluid conveyed does not exceed 140°f. this pipe meets and or exceeds the industry standards and requirements as set forth by the american society for testing and materials ( astm ) and the national sanitation foundation ( nsf international ) . , pvc materials : the material used in the manufacture of the pipe shall be rigid polyvinyl chloride ( pvc ) compound, type 1 grade 1, with a cell classification of 12454 as defined in astm d1784, trade name designation h707 pvc. this compound shall be white or gray in color as specified, and shall be approved by nsf international for use with potable water ( nsf std 61 ) . , dimensions : all sizes of pvc schedule 80 pipe shall be manufactured in strict accordance to the requirements of astm d1785 for physical dimensions and tolerances. each prodution run of pipe manufactured in compliance to this standard, shall also meet or exceed the test requirements for materials, workmanship, burst pressure, flattening, and extrusion quality defined in astm d1785. all belled end pipe shall have tapered sockets to create an interferenceptype fit, which meet or exceed the dimensional requirements and the minimum socket length for pressure type sockets as defined in astm d2672. all pvc schedule 80 pipe must also meet the requirements of nsf standard 14 and csa standard b137.3 rigid pvc pipe for pressure applications, and shall bear the mark of these listing agencies. this pipe shall have a flame spread rating of 0 25 when tested for surface burning characteristics in accordance with can / ulc s102 2 m88 or equivalent. , pvc schedule 80 pipe 3.00m length , ( i ) 15mm dia outside iameter 21.336mm, wall thickness 3.734mm, approx inside diameter 13.462mm, max. operating pressure 850 psi , ( ii ) 20mm dia outside iameter 26.670 mm, wall thickness 3.912mm, approx inside diameter 18.288mm, max. operating pressure 690 psi , ( iii ) 25mm dia outside iameter 33.401mm, wall thickness 4.547 mm, approx inside diameter 23.876mm, max. operating pressure 630 psi , ( iv ) 32mm dia outside iameter 42.164 mm, wall thickness 4.851mm, approx inside diameter 32.004mm, max. operating pressure 520 psi , ( iv ) 40mm dia outside iameter 48.260 mm, wall thickness 5.080mm, approx inside diameter 37.592mm, max. operating pressure 470 psi , ( v ) 50mm dia outside iameter 60.325 mm, wall thickness 5.537mm, approx inside diameter 48.514mm, max. operating pressure 400 psi , pvc fittings schedule 80 , application : corrosion resistant pressure pipe, ips sizes 1 / 4 through 24, for use at temperatures up to and including 140°f. pressure rating ( 120 psi to 1230 psi ) varies with schedule, pipe size, and temperature. generally resistant to most acids, bases, salts, aliphatic solutions, oxidants, and halogens. chemical resistance data is available and should be referenced for proper material selection. pipe exhibits excellent physical properties and flammability characteristics. typical allications include: chemical processing, plating, high purity applications, potable water systems, water and wastewater treatment, drainage, irrigation, agricultural, and other applications involving corrosive fluid transfer. , scope : this specification outlines minimum manufacturing requirements for polyviny chloride ( pvc ) schedule 80 iron pipe size ( ips ) pressure pipe. this pipe is intended for use in applications where the fluid conveyed does not exceed 140°f. this pipe meets and or exceeds the industry standards and requirements as set forth by the american society for testing and materials ( astm ) and the national sanitation foundation ( nsf international ) . , pvc materials : the material used in the manufacture of the pipe shall be rigid polyvinyl chloride ( pvc ) compound, type 1 grade 1, with a cell classification of 12454 as defined in astm d1784, trade name designation h707 pvc. this compound shall be white or gray in color as specified, and shall be approved by nsf international for use with potable water ( nsf std 61 ) . , dimensions : all sizes of pvc schedule 80 pipe shall be manufactured in strict accordance to the requirements of astm d1785 for physical dimensions and tolerances. each prodution run of pipe manufactured in compliance to this standard, shall also meet or exceed the test requirements for materials, workmanship, burst pressure, flattening, and extrusion quality defined in astm d1785. all belled end pipe shall have tapered sockets to create an interferenceptype fit, which meet or exceed the dimensional requirements and the minimum socket length for pressure type sockets as defined in astm d2672. all pvc schedule 80 pipe must also meet the requirements of nsf standard 14 and csa standard b137.3 rigid pvc pipe for pressure applications, and shall bear the mark of these listing agencies. this pipe shall have a flame spread rating of 0 25 when tested for surface burning characteristics in accordance with can / ulc s102 2 m88 or equivalent. , elbow 90 dgree of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , reducer socket of following size , ( i ) 20x15 mm , ( ii ) 25x15 mm , ( iii ) 25x20 mm , ( iv ) 32x25 mm , ( v ) 40x25 mm , ( vi ) 40x32 mm , ( vii ) 50x25 mm , ( viii ) 50x32 mm , ( ix ) 50x40 mm , reducer elbow of following size , ( i ) 20x15 mm , ( ii ) 25x15 mm , ( iii ) 25x20 mm , ( iv ) 32x25 mm , ( v ) 40x25 mm , ( vi ) 40x32 mm , ( vii ) 50x25 mm , ( viii ) 50x32 mm , ( ix ) 50x40 mm , tee of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , coupler of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , reducer tee of following size , ( i ) 20x15 mm , ( ii ) 25x15 mm , ( iii ) 25x20 mm , ( iv ) 32x15 mm , ( v ) 32x20 mm , ( vi ) 32x25mm , ( vii ) 40x25 mm , ( viii ) 40x32 mm , ( ix ) 50x25 mm , ( x ) 50x32 mm , ( xi ) 50x40 mm , reducer bush of following size , ( i ) 20x15 mm , ( ii ) 25x15 mm , ( iii ) 25x20 mm , ( iv ) 32x15 mm , ( v ) 32x20 mm , ( vi ) 32x25mm , ( vii ) 40x25 mm , ( viii ) 40x32 mm , ( ix ) 50x25 mm , ( x ) 50x32 mm , ( xi ) 50x40 mm , fta of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , end cap of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , mta of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , tank nipple of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , union socket of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , threaded elbow of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , ball valve of following size , ( i ) 15 mm , ( ii ) 20 mm , ( iii ) 25 mm , ( iv ) 32 mm , ( v ) 40 mm , ( vi ) 50 mm , solar submersible motor pump1hp ( 900 wp ) , designing, supplying, installation, testing & commissioning with all tools & parts of following solar photovoltaic ( spv ) solar submersible d.c. water motor pump suitable for minimum 125mm x 115mm bore well as per mnre guideline with following specifications & accessories. , spv arrays contains specified no of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual pvmodules should be minimum 300 watt peak. , i ) the spv modules should be as per iec 61215 and itc 61730 part i & ii , ii ) the efficiency of the pv modules should be minimum 13% and fill factor should be more than 70%. , iii ) all external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. , iv ) the pv modules shouldbe mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & high wind pressure up to 200km / h. , v ) the module mounting structure should be hot dip galvanized according to is 4759. , vi ) to enhance the performance of spv water pumping system & arrangement for seasonal tilt angle adjustment should be provided , vii ) necessary arrangement should be provided in controller automatic start run stop through out the day with water level detection system. ( as per mnre specification ) , viii ) necessary protection such as lightening arrestor etc. should be provided to protect the controller & spv , ix ) the suction / delivery pipe shall be upvc / h.d.p.e. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg / sq cm pe 100 grade for pump up to 3hp & 10 kg / sq cm pe 100 grade for 5 hp. , x ) all cable used shall be as per is 694. suitable size of cable shall be used in sufficient length for inter connection between the spv array to spv controller and spv controller to solar power pump. provision of cable shall be as per is 14536. , x ) the motor pump set should have a 5 years warranty. , xi ) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. ( as per mnre specification ) , xi ) the spv controller must have ip 65 protection or must be housed in cabinet having at least ip 65 protection. , xii ) the system should be as per mnre guide line & eco friendly with suitable arrangement to operate new pump manually. , xiii ) with third party inspection before dispatch. , xiv ) fitting, fixing & mounting on water tank steel structure. , xvi ) provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . it should be possible to ascertain the daily water output, the power generated by pv array , the up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs. , the following details should be marked indelibly on the motor pump set , a ) name of the manufacturer or distinctive logo. , b ) model number. , c ) serial number. , solar submersible motor pump ( spv dc type ) , i ) 1 hp ( dc pump ) with 900 wp minimum watt p.v. panel as mnre pump head max shut off head up to 120 mtrs. for higher or lower head or in between various modules output could be decided on prorates basis. ( as per latest guide line of mnre ) , solar submersible motor pump2hp ( 1800 wp ) , designing, supplying, installation, testing & commissioning with all tools & parts of following solar photovoltaic ( spv ) solar submersible d.c. water motor pump suitable for minimum 125mm x 115mm bore well as per mnre guideline with following specifications & accessories. , spv arrays contains specified no of same capacity type & specification modules connected to series or parallel to obtained the required voltage & current the power output of individual pvmodules should be minimum 200 watt peak. , i ) the spv modules should be as per iec 61215 and itc 61730 part i & ii , ii ) the efficiency of the pv modules should be minimum 13% and fill factor should be more than 70%. , iii ) all external parts of motor pump used in submersible pump which are in contact of water is stainless steel grade 303 or higher as required. , iv ) the pv modules shouldbe mounted on metallic structure of adequate strength and appropriate design which can withstand load of modules & high wind pressure up to 200km / h. , v ) the module mounting structure should be hot dip galvanized according to is 4759. , vi ) to enhance the performance of spv water pumping system & arrangement for seasonal tilt angle adjustment should be provided , vii ) necessary arrangement should be provided in controller automatic start run stop through out the day with water level detection system. ( as per mnre specification ) , viii ) necessary protection such as lightening arrestor etc. should be provided to protect the controller & spv , ix ) the suction / delivery pipe shall be upvc / h.d.p.e. pipes of appropriate size 60m or more as required minimum pressure rating of 8kg / sq cm pe 100 grade for pump up to 3hp & 10 kg / sq cm pe 100 grade for 5 hp. , x ) all cable used shall be as per is 694. suitable size of cable shall be used in sufficient length for inter connection between the spv array to spv controller and spv controller to solar power pump. provision of cable shall be as per is 14536. , xi ) the motor pump set should have a 5 years warranty. , xii ) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. ( as per mnre specification ) , xiii ) the spv controller must have ip 65 protection or must be housed in cabinet having at least ip 65 protection. , xiv ) the system should be as per mnre guide line & ecofriendly with suitable arrangement to operate new pump manually. , xv ) with third party inspection before dispatch. , xvi ) provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . it should be possible to ascertain the daily water output, the power generated by pv array , the up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs. , the following details should be marked indelibly on the motor pump set , a ) name of the manufacturer or distinctive logo. , b ) model number. , c ) serial number. , solar submersible motor pump ( spv dc type ) , i ) 2 hp ( dc pump ) with 1800 wp minimum watt p.v. panel as mnre pump head max shut off head up to 100 mtrs. for higher or lower head or in between various modules output could be decided on prorates basis. , item wise cost of componentsfor 1.0 h.p. solar submersible pump 90meter head , 1.0 h.p. solar submersible pump motor , submersible dc motor pump set , the “motor pump set” should have the following features : , i ) the mono block dc motor pump set has its driving unit and impeller mounted on a common shaft, thereby , ii ) giving it a perfect alignment. the pump should be provided with specially developed mechanical seals which ensure , iii ) zero leakage , iv ) the motor should be d.c. motor. the suction and delivery head will depend on the site specific condition of the field. , v ) submersible pumps shall be used according to the technical need of the particular case , vi ) the suction / delivery pipe ( gi / hdpe ) , electric cables, floating assembly, civil work and other fittings required to , vii ) install the system , viii ) the following details should be marked indelibly on the motor pump set. , a ) name of the manufacturer or distinctive logo , b ) model number , c ) serial number , ix ) the motor pump set should have a 5 years warranty , x ) solar submersible motor pump ( spv dc type ) 1 hp ( dc pump ) with 900 wp ( minimum ) as per mnre.head max shut off head 100 mtrs , controller for 1.0 h.p. solar submersible pump , controller for 1.0 h.p. solar submersible pump with max. power point tracking system, with dry run protection & with over flow protection & with source low protection including the cost of installation & fixing in the pump room, including with cost of m.s. channel, nut, bolt, screws etc. as per mnre guideline with following specifications & accessories. , i ) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. ( as per mnre specification ) , ii ) the spv controller must have ip 65 protection or must be housed in cabinet having at least ip 65 protection. , iii ) the system should be as per mnre guide line & ecofriendly with suitable arrangement to operate new pump manually. , iv ) with third party inspection before dispatch. , v ) provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . it should be possible to ascertain the daily water output, the power generated by pv array , the up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs. , photo voltaic modules panel , mounting structures and tracking system , the “mounting structure” should have following features: , i ) the modules support structure shall be mild steel, hot dipped galvanized ( 120 micron ) iron for holding the pv modules. the size of angle iron should not be less than 50x50x5 mm. each panel frame structure shall be so fabricated as to be grouted on ground or roof on its legs. it will withstand server cyclone / storm with the speed of 200 km / hr. , ii ) each panel frame shall be complete with a weatherproof junction box as per the relevant. , iii ) bis specifications, where the module terminals shall be interconnected and output taken. , iv ) all nuts & bolts should be made of very good quality and should be corrosion resistant , v ) the structures should be designed to allow easy replacement of any module. , vi ) the array structure shall be so designed that it will occupy minimum space without scarify the out put from the spv panels. , vii ) pv array is fixed at an angle of 23.50 for optimum use of solar energy. , viii ) the motor pump set should have a 25 years warranty , column pipe , cost ofheavy duty jointless , leak proof h.d.p.e columnpipe 32 mm dia. x 6kg / cm2holding the pump in borewell ( having the capacity of bearing load of up to 3000 kg ) with s.s. nipple screwed end fix with clamps & nut bolts, including cost of lowering in the bore well complete. , copper flexible power cable , cost of copper flexible power cable 4mm2 x 4core of approved quality and specially recommended for three phase solar pumps including the cost of jointing with lead of motor with cable tie & steel grip tape etc. including the cost of lowering in the bore well complete , safety rope , cost of g.i safety rope of required size for the safety of pump including the cost of lowering in the bore well complete. , item wise cost of componentsfor 2.0 h.p. solar submersible pump 90meter head , 2.0 h.p. solar submersible pump motor , submersible dc motor pump set , the “motor pump set” should have the following features : , i ) the mono block dc motor pump set has its driving unit and impeller mounted on a common shaft, thereby , ii ) giving it a perfect alignment. the pump should be provided with specially developed mechanical seals which ensure , iii ) zero leakage , iv ) the motor should be d.c. motor. the suction and delivery head will depend on the site specific condition of the field. , v ) submersible pumps shall be used according to the technical need of the particular case , vi ) the suction / delivery pipe ( gi / hdpe ) , electric cables, floating assembly, civil work and other fittings required to , vii ) install the system , viii ) the following details should be marked indelibly on the motor pump set. , a ) name of the manufacturer or distinctive logo , b ) model number , c ) serial number , ix ) the motor pump set should have a 5 years warranty , x ) solar submersible motor pump ( spv dc type ) 2 hp ( dc pump ) with 1800 wp ( minimum ) as per mnre.head max shut off head 100 mtrs , controller for 2.0 h.p. solar submersible pump , controller for 2.0 h.p. solar submersible pump with max. power point tracking system, with dry run protection & with over flow protection & with source low protection including the cost of installation & fixing in the pump room, including with cost of m.s. channel, nut, bolt, screws etc. as per mnre guideline with following specifications & accessories. , i ) control panel suitable for motor pump with arrangement of dry run & over flow protection sensor, float switch & rain prevention box. ( as per mnre specification ) , ii ) the spv controller must have ip 65 protection or must be housed in cabinet having at least ip 65 protection. , iii ) the system should be as per mnre guide line & ecofriendly with suitable arrangement to operate new pump manually. , iv ) with third party inspection before dispatch. , v ) provision for web basedremote monitoring of the pumps to be installed must be made through the inbuilt controllers . it should be possible to ascertain the daily water output, the power generated by pv array , the up and downtime of the pump during the year, number of days the pump was unused or under breakdown repairs. , photo voltaic modules panel , mounting structures and tracking system , the “mounting structure” should have following features: , i ) the modules support structure shall be mild steel, hot dipped galvanized ( 120 micron ) iron for holding the pv modules. the size of angle iron should not be less than 50x50x5 mm. each panel frame structure shall be so fabricated as to be grouted on ground or roof on its legs. it will withstand server cyclone / storm with the speed of 200 km / hr. , ii ) each panel frame shall be complete with a weatherproof junction box as per the relevant. , iii ) bis specifications, where the module terminals shall be interconnected and output taken. , iv ) all nuts & bolts should be made of very good quality and should be corrosion resistant , v ) the structures should be designed to allow easy replacement of any module. , vi ) the array structure shall be so designed that it will occupy minimum space without scarify the out put from the spv panels. , vii ) pv array is fixed at an angle of 23.50 for optimum use of solar energy. , viii ) the motor pump set should have a 25 years warranty , column pipe , cost ofheavy duty jointless , leak proof h.d.p.e columnpipe 32 mm dia. x 6kg / cm2holding the pump in borewell ( having the capacity of bearing load of up to 3000 kg ) with s.s. nipple screwed end fix with clamps & nut bolts, including cost of lowering in the bore well complete. , copper flexible power cable , cost of copper flexible power cable 4mm2 x 4core of approved quality and specially recommended for three phase solar pumps including the cost of jointing with lead of motor with cable tie & steel grip tape etc. including the cost of lowering in the bore well complete , safety rope , cost of g.i safety rope of required size for the safety of pump including the cost of lowering in the bore well complete. , basic rate of 65.3 mm outer dia 6.1a brass liner, 0.9 mm thick short ( for sdwp ) in 310mm length as per relevant is 15500 ( part 6 ) :2004. this part specifies the requirement of brass components used in the asembly of im ii each type of hand pump ( sdwp ) covered in this standard....

Drinking Water And Sanitation Department - Jharkhand

32223704 the quotation is invited to ascertain and assess the rate of materials at par with lowest market rate for framing of schedule of rate under d. w and s division hazaribag 1 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) 2 gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) 3 jute ( m337 ) 4 g.m. ferrules ( m922 ) 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 stop cocks ( m923 ) 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 g.m. full way valve ( m924 ) 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 g.m. non return valve verticle ( m925 ) 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 g.m. non return valve horizontal ( m926 ) 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 cocks ( m927 ) 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 chromium plated brass fittings ( m928 ) 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 connection pipe ( m929 ) 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( iv ) 32 mm 120 ( v ) 40 mm 121 ( vi ) 50 mm 122 ( vii ) 65 mm 123 ( viii ) 80 mm 124 ( ix ) 100 mm 125 ( x ) 125 mm 126 ( xi ) 150 mm 127 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 128 ( i ) 20 mm 129 ( ii ) 25 mm 130 ( iii ) 32 mm 131 ( iv ) 40 mm 132 ( v ) 50 mm 133 ( vi ) 65 mm 134 ( vii ) 80 mm 135 ( viii ) 100 mm 136 ( ix ) 125 mm 137 ( x ) 150 mm 138 [ g ] union socket of the following sizes 139 ( i ) 15 mm 140 ( ii ) 20 mm 141 ( iii ) 25 mm 142 ( iv ) 32 mm 143 ( v ) 40 mm 144 ( vi ) 50 mm 145 ( vii ) 65 mm 146 ( viii ) 80 mm 147 ( ix ) 100 mm 148 ( x ) 125 mm 149 ( xi ) 150 mm 150 [ h ] plugs of the following sizes 151 ( i ) 15 mm 152 ( ii ) 20 mm 153 ( iii ) 25 mm 154 ( iv ) 32 mm 155 ( v ) 40 mm 156 ( vi ) 50 mm 157 ( vii ) 65 mm 158 ( viii ) 80 mm 159 ( ix ) 100 mm 160 ( x ) 125 mm 161 ( xi ) 150 mm 162 [ i ] jam nuts of the following sizes 163 ( i ) 15 mm 164 ( ii ) 20 mm 165 ( iii ) 25 mm 166 ( iv ) 32 mm 167 ( v ) 40 mm 168 ( vi ) 50 mm 169 ( vii ) 65 mm 170 ( viii ) 80 mm 171 ( ix ) 100 mm 172 ( x ) 125 mm 173 ( xi ) 150 mm 174 [ j ] g.i. nipple of the following sizes 175 ( i ) 15 mm dia x 100 mm long 176 ( ii ) 20 mm dia x 100 mm long 177 ( iii ) 25 mm dia x 100 mm long 178 ( iv ) 32mm dia x 100 mm long 179 ( v ) 40 mm dia x 100 mm long 180 ( vi ) 50 mm dia x 100 mm long 181 ( vii ) 65 mm dia x 100 mm long 182 ( viii ) 80 mm dia x 100 mm long 183 ( ix ) 100 mm dia x 100 mm long 184 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 185 ( i ) 15 mm dia 186 ( ii ) 20 mm dia 187 ( iii ) 25 mm dia 188 ( iv ) 32 mm dia 189 ( v ) 40 mm dia 190 ( vii ) 65 mm dia 191 mirrors ( m931 ) 192 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 193 ( b ) do 450 mm x 300 mm do 194 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) 195 ( b ) do 450 mm x 125 mm do 196 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) 197 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 198 c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) 199 c.p. liquid soap solution holder ( m935 ) 200 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) 201 ( a ) 580 mm long 202 ( b ) 510 mm long 203 ( c ) 450 mm long 204 ( d ) 510 mm long white glazed fiber i.w.c 205 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) 206 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) 207 ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) 208 ( b ) 10.0 liters capacity p.v.c. low design cistern 209 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) 210 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 211 ( c ) black / white plastic seat for e.w.c do as above. 212 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) 213 ( b ) do squatting small 450 mm x 350 mm 214 ( c ) do squatting large 600 mm x 350 mm 215 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 216 ( e ) partition plate for urinal 25 x 13 size 217 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 218 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) 219 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) 220 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 221 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 222 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 223 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 224 drain board. ( m944 ) 225 ( a ) 600 mm x 450 mm ( 24 x 18 ) 226 ( b ) 525 mm x 450 mm ( 21 x 18 ) 227 h.c.i. pipes ( m945 ) 228 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 229 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 230 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 231 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 232 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 233 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 234 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 235 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 236 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 237 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 238 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 239 ( l ) 150 mm dia single socket 3 0 with ear 240 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 241 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 242 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 243 ( p ) 150 mm dia single socket 2 0 with ear 244 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 245 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 246 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 247 ( t ) 150 mm dia single socket 248 h.c.i. fittings. ( m946 ) 249 ( i ) plain bend of following size 250 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 251 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 252 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 253 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 254 ( ii ) bend with door with following size 255 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 256 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 257 ( c ) 100 mm dia do 5.5 kg 258 ( d ) 150 mm dia do 259 ( iii ) single junction with door of followings sizes. 260 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 261 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 262 ( c ) 100 mm dia do 9.50 kg 263 ( d ) 150 mm dia do 264 ( iv ) double junction with door of following sizes. 265 ( a ) 50 mm dia do 4.5 kg 266 ( b ) 80 mm dia do 7.00 kg 267 ( c ) 100 mm dia do 13.00 kg 268 ( d ) 150 mm dia do 269 ( v ) heel rest bend of following sizes 270 ( a ) 50 mm dia 271 ( b ) 80 mm dia 272 ( c ) 100 mm dia 273 ( d ) 150 mm dia 274 ( vi ) cowel of following sizes 275 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 276 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 277 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 278 ( d ) 150 mm dia do 279 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 280 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 281 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 282 ( x ) pass over 50 mm x 150 mm for 50 mm projection 283 ( xi ) do 100 mm x 150 mm for 100 mm projection 284 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 285 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 286 ( xiv ) h.c.i. offset 80 mm projection of the following size 287 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 288 ( b ) 80 mm dia do 3.50 kg 289 ( c ) 100 mm dia do 5.00 kg 290 ( d ) 150 mm dia do 291 ( xv ) h.c.i. socket of following sizes 292 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 293 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 294 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 295 ( d ) 150 mm dia ( weight without ear ) do 296 c.i. cover with frame for manhole and inspection chamber. ( m947 ) 297 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 298 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 299 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 300 c.i. bracket pair for w.h.b. ( m948 ) 301 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 302 ( b ) do for 12.5 liter cistern 303 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 304 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 305 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) 306 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 307 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 308 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 309 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) 310 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 311 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) 312 rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) 313 pig lead ( m953 ) 314 yarn ( m954 ) 315 rubber gasket for c.i pipe of good quality ( m955 ) 316 ( a ) 80 mm 317 ( b ) 100 mm 318 ( c ) 125 mm 319 ( d ) 150 mm 320 ( e ) 200 mm 321 ( f ) 250 mm 322 ( g ) 300 mm 323 ( h ) 350 mm 324 ( i ) 400 mm 325 ( j ) 450 mm 326 ( k ) 500 mm 327 ( l ) 600 mm 328 ( m ) 700 mm 329 ( n ) 750 mm 330 ( o ) 800 mm 331 ( p ) 900 mm 332 ( q ) 1000 mm 333 ( r ) 1200 mm 334 cotton waste ( m956 ) 335 asbestos suta ( gland packing ) ( m957 ) 336 solvent cement ( m958 ) 337 hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) 338 cp & pvc fitting ( m960 ) 339 ( i ) 32 mm dia c.p. waste 340 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 341 ( iii ) 40 mm dia c.p. waste 342 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 343 ( v 100 mm dia steel jali 344 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 345 ( vii ) 50 mm dia pvc pipe with coupling 346 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) 347 ( i ) pillar cock ( isi ) 348 ( ii ) pillar cock ( long neck ) 349 ( iii ) bib cock ( isi ) 350 ( iv ) bib cock ( long thread ) 351 ( v ) angular stop cock 352 ( vi ) angular stop cock ( long thread ) 353 ( vii ) concealed stop cock reduce ( isi ) 354 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 355 ( ix ) long body bib cock 356 ( x ) swan neck tap with left hand operating knob 357 ( xi ) central hole basin mixer ( best quality ) 358 ( xii ) wall mixer with telephonic shower arrangement 359 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 360 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 361 ( xv ) sink mixer with swinging casted spout 362 ( xvi ) sink cock with swinging casted spout 363 ( xvii ) 4 way diverter for concealed fittings 364 ( xviii ) pressure adjustable shower with revolving joint 365 ( xix ) telephone shower with flexible pipe 366 ( xx ) flush cock with wall flange ( 25 mm ) 367 ( xxi ) towel rail 24 368 ( xxii ) towel ring 369 ( xxiii ) soap dish 370 ( xxiv ) tumbler holder 371 ( xxv ) toilet paper holder 372 ( xxvi ) glass shelf 22 373 ( xxvii ) corner glass shelf with bracket 374 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 375 c.i special & pvc pipes ( m962 ) 376 1. c.i double shocketted fittings bend such as bend, tee, taper, 377 ( a ) 80 200 mm 378 ( b ) 250 700 mm 379 ( c ) 700 1000 mm 380 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 381 ( a ) 80 200 mm 382 ( b ) 250 700 mm 383 ( c ) 700 1000 mm 384 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) 385 providing and supplying of isi standarddi specials & fitting with sealing rubber gasket of sbr, complete with cast iron follower gland & ms nut bolts coated or otherwise protected from rusting and suitable for di pipescomplete as per is 9523 class k 12 ( ex factoryrates ) inspection charge transportation , cp extra. ( m1027 ) 386 socketed 387 100 150 mm dia 388 200 300mm dia 389 350 450mm dia 390 500 600mm dia 391 700 mm dia 392 800 mm dia 393 900 mm dia 394 1000 mm dia 395 1100 mm dia 396 1200 mm dia 397 flanged 398 100 150 mm dia 399 200 300 mm dia 400 350 450mm dia 401 500 600mm dia 402 700 mm dia 403 800 mm dia 404 900 mm dia 405 1000 mm dia 406 1100 mm dia 407 1200 mm dia 408 rcc esr ( m1030 ) 409 designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. 410 notes 411 the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) 412 the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. 413 for design having more than 6 columns, suitable bracing is obligatory. 414 plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed 415 irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 416 these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. 417 staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 418 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 419 all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 420 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 421 the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . 422 for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. 423 below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. 424 the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. 425 the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 426 12 to 16 m staging 2% per metre 427 16 to 20 m staging 3% per metre 428 20 m and above 4% per metre 429 for 17 m staging height, percentage calculation will be like below : 430 12 to 16 m 4 x 2 = 8% 431 16 & 17 m 1 x 3% = 3% total = 11% 432 for 21 m staging height, percentage calculation will be like below : 433 12 to 16 m 4 x 2 = 8% 434 16 to 20 m 4 x 3% = 12% 435 20& 21 m 1 x 4% = 4% total = 24% 436 following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . 437 notes 438 conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. 439 conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. 440 rates for rcc esrs 441 upto 25, 000 litres 442 cost of 25, 000 litres capacity 443 add for capacity above 25, 000 upto 50, 000 litres 444 cost of 50, 000 litres capacity 445 add for capacity above 50, 000 upto 75, 000 litres 446 cost of 75, 000 litres capacity 447 add for capacity above 75, 000 upto 1, 00, 000 litres 448 cost of 1, 00, 000 litres capacity 449 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 450 cost of 1, 50, 000 litres capacity 451 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 452 cost of 2, 00, 000 litres capacity 453 add for capacity above 2, 00, 000 upto 2, 50, 000 litres 454 cost of 2, 50, 000 litres capacity 455 add for capacity above 2, 50, 000 upto 3, 00, 000 litres 456 cost of 3, 00, 000 litres capacity 457 add for capacity above 3, 00, 000 upto 4, 00, 000 litres 458 cost of 4, 00, 000 litres capacity 459 add for capacity above 4, 00, 000 upto 5, 00, 000 litres 460 cost of 5, 00, 000 litres capacity 461 add for capacity above 5, 00, 000 upto 7, 50, 000 litres 462 cost of 7, 50, 000 litres capacity 463 add for capacity above 7, 50, 000 upto 10, 00, 000 litres 464 cost of 10, 00, 000 litres capacity 465 add for capacity above 10, 00, 000 upto 15, 00, 000 litres 466 cost of 15, 00, 000 litres capacity 467 add for capacity above 15, 00, 000 upto 20, 00, 000 litres 468 cost of 20, 00, 000 litres capacity 469 rcc gsr and sump ( m1031 ) 470 designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. 471 anti –termite treatment shall be given for under ground portion of the structure. 472 notes 473 the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) 474 only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. 475 entire structure shall be in m 300 only. 476 the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 477 the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. 478 the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. 479 g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. 480 for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. 481 cost of pump house is not included in these rates. 482 above rates are applicable for seismic zones 2, 3 and 4. 483 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 484 10% shall be added for sump if over head pump house is proposed. 485 note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. 486 rates for rcc gsrs and sumps 487 upto 25, 000 litres 488 cost of 25, 000 litres capacity 489 add for capacity above 25, 000 upto 50, 000 litres 490 cost of 50, 000 litres capacity 491 add for capacity above 50, 000 upto 75, 000 litres 492 cost of 75, 000 litres capacity 493 add for capacity above 75, 000 upto 1, 00, 000 litres 494 cost of 1, 00, 000 litres capacity 495 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 496 cost of 1, 50, 000 litres capacity 497 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 498 cost of 2, 00, 000 litres capacity 499 add for capacity above 2, 00, 000 upto 3, 00, 000 litres 500 cost of 3, 00, 000 litres capacity 501 add for capacity above 3, 00, 000 upto 5, 00, 000 litres 502 cost of 5, 00, 000 litres capacity 503 add for capacity above 5, 00, 000 upto 10, 00, 000 litres 504 cost of 10, 00, 000 litres capacity 505 addforcapacityabove10, 00, 000upto15, 00, 000 litres 506 cost of 15, 00, 000 litres capacity 507 add for capacity above 15, 00, 000 litres 508 note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. 509 unconventionalwater treatment plant ( m1032 ) 510 designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. 511 aeration fountain 512 inlet arrangements 513 mixing channel with ventury flume and flow measuring arrangement 514 inlet channel 515 flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes 516 tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance 517 rapid sand gravity filters all valve shall be glandless. 518 filter house 519 chemical house 520 alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 521 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. 522 tcl solution tank with mixing, carrying and dosing arrangement with piping. 523 bypass arrangement 524 external and internal electrification 525 laboratory equipments 526 wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. 527 wash water pumps with 100% standby 528 air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. 529 pure water sump of capacity equal to 1 hourpumping capacity. 530 pure water pump house over the sump / by the side of sump. 531 drainage arrangements 532 alum store 533 sanitary block with necessary water supply and drainage arrangements and internalwbm roads. 534 these rates are applicable for seismic zones 2, 3 and 4. 535 rates given below are inclusive of uplift pressure if any and dewatering during the entire work. 536 all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. 537 unconventional treatment plants less than 1 mld capacity shall not be constructed. 538 all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . 539 note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. 540 unconventional water treatment plant 541 fixed cost for 1 mld 542 add for capacity above 1 mld upto 2 mld 543 cost of 2 mld treatment plant 544 add for capacity above 2 mld upto 3 mld 545 cost of 3 mld treatment plant 546 conventionalwater treatment plant ( m1033 ) 547 designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . 548 aeration fountain plan are a not less than 0.625 square metre per mld 549 ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) 550 flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. 551 flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. 552 clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. 553 rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. 554 filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. 555 wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. 556 wash water pumps capacity to fill water tank in 1 hour with 100% standby. 557 air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . 558 chemical house in two storeys 559 ground floor to accommodate 7 days alum requirement and sundry storage. 560 first floor to accommodate alum and lime tanks.etc. 561 solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. 562 pure water sump and sump house. 563 capacity of sump – one hour of designed flow. 564 pump house pump house of required size over the sump or by the side. 565 store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. 566 vacuum feed type chlorinators make tobe approved by mjp. 567 conforming to i.s. 10533 a part ii 1983 568 rate for withdrawal 569 temperature kg. of chlorine discharge degree c per day ( cylinders ) 570 45 67 tonnes 571 10 6.359.50 110 572 15 10.75 16.10130 573 20 14.50 21.24254 574 27&above18.70 28.12315 575 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 576 100% standby shall be provided. 577 by pass arrangements c.i. or m.s. pipes. 578 disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe 579 for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete 580 drainage arrangements – rcc pipes up to plot boundary. 581 electrical installation – both internal and external including entire plant area. 582 laboratory equipment –as per requirement ( to be specified during tendering ) . 583 sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. 584 administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. 585 rates given below are inclusive of up lift pressure if any and dewatering during entire work. 586 all pipes condutes channels with20%overloading 587 these rates are applicable for seismic zones 2, 3 and 4. 588 all rcc structures shall be constructed in m 300. 589 note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . 590 conventional water treatment plant 591 above3 mld to upto 5 mld 592 cost of 5 mld treatment plant 593 add for capacity above 5mld upto 10 mld 594 cost of 10 mld treatment plant 595 add for capacity above 10 mld upto20 mld 596 cost of 20 mld treatment plant 597 add for capacity above 20 mld upto 50 mld 598 cost of 50 mld treatment plant 599 add for capacityabove 50 mld upto 100 mld 600 cost of 100 mld treatment plant 601 add for capacity above 100 mld 602 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) 603 300 mm dia for gpt 604 400 mm dia for hygpt 605 hydt :cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) 606 from 0 50 meter 607 from 51 125 meter 608 dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) 609 drillig upto 30 mtr depth below g. l. in rural area 610 drilling beyond 31 mtr upto 60 mtr below g. l. in rural area 611 trenchless ( m1038 ) 612 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 613 from 900 mm to 1000 mm dia 614 in soft soil 615 in hard soil 616 in sandy soil 617 in stone soil 618 from 1000 mm to 1200 mm dia 619 in soft soil 620 in hard soil 621 in sandy soil 622 in stone soil 623 above 1200 mm to 1500 mm dia 624 in soft soil 625 in hard soil 626 in sandy soil 627 in stone soil 628 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 629 upto 300 mm dia 630 in soft soil 631 in hard soil 632 in sandy soil 633 in stone soil 634 above300 mm to 450 mm dia 635 in soft soil 636 in hard soil 637 in sandy soil 638 in stone soil 639 above 450 mm to 600 mm dia 640 in soft soil 641 in hard soil 642 in sandy soil 643 in stone soil 644 above 600 mm to 900 mm dia 645 in soft soil 646 in hard soil 647 in sandy soil 648 in stone soil 649 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 650 upto 300 mm dia 651 in soft soil 652 in hard soil 653 in sandy soil 654 in stone soil 655 above300 mm to 450 mm dia 656 in soft soil 657 in hard soil 658 in sandy soil 659 in stone soil 660 above 450 mm to 600 mm dia 661 in soft soil 662 in hard soil 663 in sandy soil 664 in stone soil 665 above 600 mm to 900 mm dia 666 in soft soil 667 in hard soil 668 in sandy soil 669 in stone soil 670 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) 671 without byepass arrangement pn 1 672 50 mm 673 65 mm 674 80 mm 675 100 mm 676 125 mm 677 150 mm 678 200 mm 679 250 mm 680 300 mm 681 350 mm 682 400 mm 683 450 mm 684 500 mm 685 600 mm 686 700 mm 687 750 mm 688 800 mm 689 900 mm 690 1000 mm 691 1100 mm 692 1200 mm 693 with byepass arrangement pn 1 694 50 mm 695 65 mm 696 80 mm 697 100 mm 698 125 mm 699 150 mm 700 200 mm 701 250 mm 702 300 mm 703 350 mm 704 400 mm 705 450 mm 706 500 mm 707 600 mm 708 700 mm 709 750 mm 710 800 mm 711 900 mm 712 1000 mm 713 1100 mm 714 1200 mm 715 without byepass arrangement pn 1.6 716 50 mm 717 65 mm 718 80 mm 719 100 mm 720 125 mm 721 150 mm 722 200 mm 723 250 mm 724 300 mm 725 350 mm 726 400 mm 727 450 mm 728 500 mm 729 600 mm 730 with byepass arrangement pn 1.6 731 50 mm 732 65 mm 733 80 mm 734 100 mm 735 125 mm 736 150 mm 737 200 mm 738 250 mm 739 300 mm 740 350 mm 741 400 mm 742 450 mm 743 500 mm 744 600 mm 745 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 746 with byepass arrangement pn 1 747 50 mm 748 65 mm 749 80 mm 750 100 mm 751 125 mm 752 150 mm 753 200 mm 754 250 mm 755 300 mm 756 350 mm 757 400 mm 758 450 mm 759 500 mm 760 600 mm 761 700mm 762 750 mm 763 800 mm 764 900 mm 765 1000 mm 766 1100 mm 767 1200mm 768 without byepass arrangement pn 1 769 50 mm 770 65 mm 771 80 mm 772 100 mm 773 125 mm 774 150 mm 775 200 mm 776 250 mm 777 300 mm 778 350 mm 779 400 mm 780 450 mm 781 500 mm 782 600 mm 783 700mm 784 750 mm 785 800 mm 786 900 mm 787 1000 mm 788 1100 mm 789 1200mm 790 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 791 without byepass arrangement pn 1.6 792 50 mm 793 65 mm 794 80 mm 795 100 mm 796 125 mm 797 150 mm 798 200 mm 799 250 mm 800 300 mm 801 350 mm 802 400 mm 803 450 mm 804 500 mm 805 600 mm 806 700mm 807 750 mm 808 800 mm 809 900 mm 810 1000 mm 811 1100 mm 812 1200mm 813 with byepass arrangement pn 1.6 814 50 mm 815 65 mm 816 80 mm 817 100 mm 818 125 mm 819 150 mm 820 200 mm 821 250 mm 822 300 mm 823 350 mm 824 400 mm 825 450 mm 826 500 mm 827 600 mm 828 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) 829 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) 830 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) 831 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) 832 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) 833 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) 834 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) 835 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) 836 supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) 837 supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) 838 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) 839 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) 840 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) 841 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) 842 packaged lamella clarified type wtp with mgf capacity in mld. 843 size 0.2 844 size 0.3 845 size 0.4 846 size 0.5 847 size 0.6...

Drinking Water And Sanitation Department - Jharkhand

32223666 government of jharkhand through its public works department ( pwd ) is engaged in framing / revision of schedule of rates and as part of this endeavor, quotations through etender are invited for rate of items / materials annexed as annexure 1m079 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system per liter m193 gi pipe 50 mm dia ( tata or equivalent make ) m m337 jute p / kg m922 g.m. ferrules ( i ) 8 mm dia wt. not less than 400 gms each ( ii ) 10 mm dia wt. not less than 400 gms each ( iii ) 15 mm dia wt. not less than 400 gms each ( iv ) 20 mm dia wt. not less than 600 gms each ( v ) 25 mm dia wt. not less than 900 gms each m923 stop cocks ( i ) 15 mm brass stop cock wt. not less than 300 gms each ( ii ) 20 mm brass stop cock wt. not less than 400 gms each ( iii ) 25 mm brass stop cock wt. not less than 575 gms each ( iv ) 32 mm brass stop cock wt. not less than 850 gms each ( v ) 40 mm brass stop cock wt. not less than 1.15 kg each ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg each ( vii ) 15 mm dia c.i. body brass working part stop cock. each ( viii ) 20 mm dia c.i. body brass working part stop cock. each ( ix ) 25 mm dia c.i. body brass working part stop cock. each m924 g.m. full way valve ( i ) 15 mm dia wt. not less than 300 gms without wheel each ( ii ) 20 mm dia wt. not less than 400 gms without wheel each ( iii ) 25 mm dia wt. not less than 500 gms without wheel each ( iv ) 32 mm dia wt. not less than 700 gms without wheel each ( v ) 40 mm dia wt. not less than 1.0 kg without wheel each ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel each ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel each ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel each m925 g.m. non return valve verticle ( i ) 15 mm dia wt. not less than 150 gms each ( ii ) 20 mm dia wt. not less than 250 gms each ( iii ) 25 mm dia wt. not less than 375 gms each ( iv ) 32 mm dia wt. not less than 600 gms each ( v ) 40 mm dia wt. not less than 700 gms each ( vi ) 50 mm dia wt. not less than 1.0 kg each ( vii ) 65 mm dia wt. not less than 1.20 kg each ( viii ) 80 mm dia wt. not less than 1.50 kg each ( ix ) 100 mm dia wt. not less than 1.80 kg each m926 g.m. non return valve horizontal ( i ) 15 mm dia wt. not less than 150 gms each ( ii ) 20 mm dia wt. not less than 250 gms each ( iii ) 25 mm dia wt. not less than 375 gms each ( iv ) 32 mm dia wt. not less than 600 gms each ( v ) 40 mm dia wt. not less than 700 gms each ( vi ) 50 mm dia wt. not less than 1.0 kg each ( vii ) 65 mm dia wt. not less than 1.20 kg each ( viii ) 80 mm dia wt. not less than 1.50 kg each ( ix ) 100 mm dia wt. not less than 1.80 kg each m927 cocks ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms each ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms each ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms each ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms each ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms each ( vi ) 15 mm c.i. plug cock ordinary each ( vii ) 15 mm c.i. push cock ordinary each m928 chromium plated brass fittings ( i ) c.p. shower rose 100 mm dia each ( ii ) c.p. shower rose 125 mm dia each ( iii ) p.v.c. shower rose 150 mm dia each ( iv ) p.v.c shower rose 125 mm dia each m929 connection pipe ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. each ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. each ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. each ( iv ) 15 mm dia x 45 cm. long pvc connection pipe with brass fittings. each m930 g.i. fittings ( conforming to i.s. 1879 ) isi marked [ a ] g.i. bend ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ b ] elbow of the following sizes ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ c ] tee plain of the following sizes ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ d ] reducing tee plain of the following sizes ( taking larger dimension ) ( i ) 20 mm each ( ii ) 25 mm each ( iii ) 32 mm each ( iv ) 40 mm each ( v ) 50 mm each ( vi ) 65 mm each ( vii ) 80 mm each ( viii ) 100 mm each ( ix ) 125 mm each ( x ) 150 mm each [ e ] socket plain of the following size ( taking larger dimension ) ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ f ] reducing socket plain of the following sizes ( taking larger dimension ) ( i ) 20 mm each ( ii ) 25 mm each ( iii ) 32 mm each ( iv ) 40 mm each ( v ) 50 mm each ( vi ) 65 mm each ( vii ) 80 mm each ( viii ) 100 mm each ( ix ) 125 mm each ( x ) 150 mm each [ g ] union socket of the following sizes ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ h ] plugs of the following sizes ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ i ] jam nuts of the following sizes ( i ) 15 mm each ( ii ) 20 mm each ( iii ) 25 mm each ( iv ) 32 mm each ( v ) 40 mm each ( vi ) 50 mm each ( vii ) 65 mm each ( viii ) 80 mm each ( ix ) 100 mm each ( x ) 125 mm each ( xi ) 150 mm each [ j ] g.i. nipple of the following sizes ( i ) 15 mm dia x 100 mm long each ( ii ) 20 mm dia x 100 mm long each ( iii ) 25 mm dia x 100 mm long each ( iv ) 32mm dia x 100 mm long each ( v ) 40 mm dia x 100 mm long each ( vi ) 50 mm dia x 100 mm long each ( vii ) 65 mm dia x 100 mm long each ( viii ) 80 mm dia x 100 mm long each ( ix ) 100 mm dia x 100 mm long each [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality ( i ) 15 mm dia per mtr. ( ii ) 20 mm dia per mtr. ( iii ) 25 mm dia per mtr. ( iv ) 32 mm dia per mtr. ( v ) 40 mm dia per mtr. ( vii ) 65 mm dia per mtr. m931 mirrors ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror including c.p. brass revolving fittings 3 mm plywood board and c.p. hinges etc. to fix the mirror each ( b ) do 450 mm x 300 mm do each m932 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail each ( b ) do 450 mm x 125 mm do each m933 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete each ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets each m934 c.p. brass soap dish medium quality with screw and hinges etc. each m935 c.p. liquid soap solution holder each m936 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or any other equivalent make ( a ) 580 mm long each ( b ) 510 mm long each ( c ) 450 mm long each ( d ) 510 mm long white glazed fiber i.w.c each m937 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make each m938 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket each m939 ( a ) 12.5 liters lowdown c.i. cistern each ( b ) 10.0 liters capacity p.v.c. low design cistern each m940 ( a ) white glazed vitreous e.w.c with p trap or any other equivalent make each ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make each ( c ) black / white plastic seat for e.w.c do as above. each m941 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size each ( b ) do squatting small 450 mm x 350 mm each ( c ) do squatting large 600 mm x 350 mm each ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make each ( e ) partition plate for urinal 25 x 13 size each ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings each m942 white glazed vitreous wash hand basin 550 mm x 400 mm size of hindustan / parryware / cera / naycer or any other equivalent make each m943 white glazed vitreous earthen ware kitchen sinks of hindustan / parryware / cera / naycer or any other equivalent make ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) each ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) each ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) each ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) each m944 drain board ( a ) 600 mm x 450 mm ( 24 x 18 ) each ( b ) 525 mm x 450 mm ( 21 x 18 ) each m945 h.c.i. pipes ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) each ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) each ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) each ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) each ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) each ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) each ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) each ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) each ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) each ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) each ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) each ( l ) 150 mm dia single socket 3 0 with ear each ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) each ( n ) 80 mm dia single socket 2 0 ( with ear weight 8.00 kg ) each ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) each ( p ) 150 mm dia single socket 2 0 with ear each ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) each ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) each ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) each ( t ) 150 mm dia single socket each m946 h.c.i. fittings. ( i ) plain bend of following size ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) each ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) each ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) each ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) each ( ii ) bend with door with following size ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) each ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) each ( c ) 100 mm dia do 5.5 kg each ( d ) 150 mm dia do each ( iii ) single junction with door of followings sizes. ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) each ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) each ( c ) 100 mm dia do 9.50 kg each ( d ) 150 mm dia do each ( iv ) double junction with door of following sizes. ( a ) 50 mm dia do 4.5 kg each ( b ) 80 mm dia do 7.00 kg each ( c ) 100 mm dia do 13.00 kg each ( d ) 150 mm dia do each ( v ) heel rest bend of following sizes ( a ) 50 mm dia each ( b ) 80 mm dia each ( c ) 100 mm dia each ( d ) 150 mm dia each ( vi ) cowel of following sizes ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) each ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) each ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) each ( d ) 150 mm dia do each ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg each ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg each ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg each ( x ) pass over 50 mm x 150 mm for 50 mm projection each ( xi ) do 100 mm x 150 mm for 100 mm projection each ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg each ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg each ( xiv ) h.c.i. offset 80 mm projection of the following size ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg each ( b ) 80 mm dia do 3.50 kg each ( c ) 100 mm dia do 5.00 kg each ( d ) 150 mm dia do each ( xv ) h.c.i. socket of following sizes ( a ) 50 mm dia ( weight without ear ) 1.50 kg each ( b ) 80 mm dia ( weight without ear ) 3.00 kg each ( c ) 100 mm dia ( weight without ear ) 4.50 kg each ( d ) 150 mm dia ( weight without ear ) do each m947 c.i. cover with frame for manhole and inspection chamber ( a ) 600 mm x 450 mm size ( wt. 39 kg ) each ( b ) 600 mm x 450 mm size ( wt. 25 kg ) each ( c ) 500 mm x 450 mm size ( wt. 25 kg ) each m948 c.i. bracket pair for w.h.b ( a ) 550 mm x 400 mm size ( 22 x 16 ) each ( b ) do for 12.5 liter cistern each ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink each ( d ) 40 mm x 60 mm ms plate bracket for sink as above each m949 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b each ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink each ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal each ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal each m950 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b each ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b each m951 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern each m952 rubber inserttion 3 mm ( 1 / 8 ) thick per kg m953 pig lead per kg m954 yarn per kg m955 rubber gasket for c.i pipe of good quality ( a ) 80 mm each ( b ) 100 mm each ( c ) 125 mm each ( d ) 150 mm each ( e ) 200 mm each ( f ) 250 mm each ( g ) 300 mm each ( h ) 350 mm each ( i ) 400 mm each ( j ) 450 mm each ( k ) 500 mm each ( l ) 600 mm each ( m ) 700 mm each ( n ) 750 mm each ( o ) 800 mm each ( p ) 900 mm each ( q ) 1000 mm each ( r ) 1200 mm each m956 cotton waste p / kg m957 asbestos suta ( gland packing ) p / kg m958 solvent cement p / kg m959 hydrocloric acid ( sepecific gravity 1.20 ) p / lit m960 cp & pvc fitting ( i ) 32 mm dia c.p. waste each ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling each ( iii ) 40 mm dia c.p. waste each ( iv 40 mm dia pvc waste pipe 750 mm long with coupling each ( v 100 mm dia steel jali each ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) each ( vii ) 50 mm dia pvc pipe with coupling each m961 special type of c.p. bath room fittings for v.i.p. buildings ( jal, jaquar, marc or equivalent mark ) ( i ) pillar cock ( isi ) eech ( ii ) pillar cock ( long neck ) each ( iii ) bib cock ( isi ) each ( iv ) bib cock ( long thread ) each ( v ) angular stop cock each ( vi ) angular stop cock ( long thread ) each ( vii ) concealed stop cock reduce ( isi ) each ( viii ) concealed stop cock heavy duty extra adjustable wall flange each ( ix ) long body bib cock each ( x ) swan neck tap with left hand operating knob each ( xi ) central hole basin mixer ( best quality ) each ( xii ) wall mixer with telephonic shower arrangement each ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange each ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange each ( xv ) sink mixer with swinging casted spout each ( xvi ) sink cock with swinging casted spout each ( xvii ) 4 way diverter for concealed fittings each ( xviii ) pressure adjustable shower with revolving joint each ( xix ) telephone shower with flexible pipe each ( xx ) flush cock with wall flange ( 25 mm ) each ( xxi ) towel rail 24 each ( xxii ) towel ring each ( xxiii ) soap dish each ( xxiv ) tumbler holder each ( xxv ) toilet paper holder each ( xxvi ) glass shelf 22 each ( xxvii ) corner glass shelf with bracket each ( xxviii ) flush valve complete with 32 mm size control cock & flange each m962 c.i special & pvc pipes 1. c.i double shocketted fittings bend such as bend, tee, taper, ( a ) 80 200 mm per / kg ( b ) 250 700 mm per / kg ( c ) 700 1000 mm per / kg 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc ( a ) 80 200 mm per / kg ( b ) 250 700 mm per / kg ( c ) 700 1000 mm per / kg spare parts of hand pump m963 hexagonal bolt m12x1.75x40mm long common to marks ii & iii each m964 hexagonal nut m12x1.75mm each m965 washer m12 ( 2.5mm thick ) each m966 high tensile bolt m10x1.5x40mm long. each m967 nyloc nut m10x1.5mm each m968 handle axle ( stainless steel ) each m969 washer for handle axle ( 4mm thick ) each m970 ball bearing 6204 z each m971 spacer for handle. each m972 chain with coupling. each m973 hexagonal bolt for front cover m12x1.75mm long. each m974 nitrile rubber cup washer for mark – ii & iii each m975 nitrile sealing ring mark – ii each m976 nitrile rubber seating big for lower valve mark ii each m977 nitrile rubber seating small for upper valve mark ii. each m978 hexagonal rod coupling m12x1.75x50mm long. each m979 pump head assembly ( g.i. ) with front cover, bolt & third plate. each m980 front cover ( g.i. ) each m981 handle assembly ( g.i. ) each m982 ( a ) water tank assembly for mark – ii ( g.i. ) each ( b ) water tank assembly for mark – iii ( vlom 65 ) each m983 stand assembly ( g.i. ) normal. each m984 stand assembly ( telescopic ) ( g.i ) . each m985 connecting rod 3mtr. long with coupling and nut ( electrogalvanized ) each m986 a ) cylinder assembly complete set for mark ii each b ) cylinder assembly complete set for mark iii ( vlom 65 ) each m987 a ) upper valve assembly complete set for india mark ii each b ) upper valve assembly complete set for india mark iii ( vlom 65 ) each m988 a ) lower valve assembly complete set for india mark ii each b ) lower valve assembly complete set for im iii each m989 reducer cap for cylinder mark ii each m990 a ) plunger rod ( s.s. ) for mark – ii each b ) plunger rod ( s.s. ) for mark – iii each m991 upper valve guide ( g.m. ) . each m992 rubber seat retainer for mark ii each m993 third plate for head assembly ( galanized ) each m994 cylinder body with brass liner for im ii with reducer cap for top and bottom. each m995 gun metal spacer. each m996 check valve guide mark ii each m997 a ) check valve seat for mark – ii each b ) check valve seat for mark – iii each m998 nitrile rubber “o” ring ( vlom 65 ) each m999 push rod for mark – iii ( s.s ) . each m1000 check nut for push rod ( s.s. ) . each m1001 nitrile rubber cup washer for vlom 50 each m1002 nitrile rubber sealing ring for mark – iii vlom 65 each m1003 nitrile rubber seating big for lower valve mk ii each m1004 nitrile rubber seating big for lower valve m iii vlom 65 ) each m1005 nitrile rubber bobbin vlom 50 each m1006 nitrile rubber “o” ring vlom 50 each m1007 nitrile rubber cone for vlom 50 each m1008 nitrile rubber cone for vlom 65 each m1009 nitrile rubber centralizer 150mm for ( vlom 65 ) . each m1010 nitrile rubber centralizer 125mm for ( vlom 65 ) . each m1011 nitrile rubber centralizer 150mm for ( vlom 50 ) . each m1012 nitrile rubber centralizer 125mm for vlom 50 each m1013 nitrile rubber centralizer 100mm for vlom 50 each m1014 water tank assembly mark – iii vlom 50 each m1015 cylinder assembly complete set for mark – iii ( vlom 50 ) each m1016 upper valve assembly complete set for im iii ( vlom 50 ) each m1017 lower valve assembly complete set for im iii ( vlom 50 ) each m1018 a ) upper cap cylinder mark – iii ( vlom 65 ) each b ) upper cap cylinder mark – iii ( vlom 50 ) each m1019 a ) bottom cap for mark – iii ( vlom 50 ) each b ) bottom cap for mark – iii ( vlom 65 ) each m1020 follower for im iii each m1021 cage for mark iii each m1022 s.s. hexagonal bolt m 6x25mm long. each m1023 basic rate of standard i.s.i. mark deep well hand pump for india mark 2, i.s.i. 15500 ( part 2 ) / 2004 with latest revision including 12mm x 3meter long 8 no. connecting rods made of bright bar electro galvanized fitted with coupler & normal stand assembly ecommended for use with cylinder assembly suitable for bore well dia 100 to 125mm casing pipe. each m1024 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 p / m m1025 basic rate of 32mm g.i. pipe in 3 mtrs. length ( medium ) with seamless socket as per relevent b.i.s. specification is 1239 ( part i ) / 2004 p / m m1030 rcc esr designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracings including refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluing roof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on the reservoir as per the directions of engineer in charge. notes the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. for design having more than 6 columns, suitable bracing is obligatory. plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imild steel bars will not be allowed irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of 5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 12 to 16 m staging 2% per metre 16 to 20 m staging 3% per metre 20 m and above 4% per metre for 17 m staging height, percentage calculation will be like below : 12 to 16 m 4 x 2 = 8% 16 & 17 m 1 x 3% = 3% total = 11% for 21 m staging height, percentage calculation will be like below : 12 to 16 m 4 x 2 = 8% 16 to 20 m 4 x 3% = 12% 20& 21 m 1 x 4% = 4% total = 24% following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . notes conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. rates for rcc esrs upto 25, 000 litres lit. cost of 25, 000 litres capacity job add for capacity above 25, 000 upto 50, 000 litres lit. cost of 50, 000 litres capacity job add for capacity above 50, 000 upto 75, 000 litres lit. cost of 75, 000 litres capacity job add for capacity above 75, 000 upto 1, 00, 000 litres lit. cost of 1, 00, 000 litres capacity job add for capacity above 1, 00, 000 upto 1, 50, 000 litres lit. cost of 1, 50, 000 litres capacity job add for capacity above 1, 50, 000 upto 2, 00, 000 litres lit. cost of 2, 00, 000 litres capacity job add for capacity above 2, 00, 000 upto 2, 50, 000 litres lit. cost of 2, 50, 000 litres capacity job add for capacity above 2, 50, 000 upto 3, 00, 000 litres lit. cost of 3, 00, 000 litres capacity job add for capacity above 3, 00, 000 upto 4, 00, 000 litres lit. cost of 4, 00, 000 litres capacity job add for capacity above 4, 00, 000 upto 5, 00, 000 litres lit. cost of 5, 00, 000 litres capacity job add for capacity above 5, 00, 000 upto 7, 50, 000 litres lit. cost of 7, 50, 000 litres capacity job add for capacity above 7, 50, 000 upto 10, 00, 000 litres lit. cost of 10, 00, 000 litres capacity job add for capacity above 10, 00, 000 upto 15, 00, 000 litres lit. cost of 15, 00, 000 litres capacity job add for capacity above 15, 00, 000 upto 20, 00, 000 litres lit. cost of 20, 00, 000 litres capacity job m1031 rcc gsr and sump designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. anti –termite treatment shall be given for under ground portion of the structure. notes the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. entire structure shall be in m 300 only. the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. cost of pump house is not included in these rates. above rates are applicable for seismic zones 2, 3 and 4. 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 10% shall be added for sump if over head pump house is proposed. note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. rates for rcc gsrs and sumps upto 25, 000 litres lit. cost of 25, 000 litres capacity job add for capacity above 25, 000 upto 50, 000 litres lit. cost of 50, 000 litres capacity job add for capacity above 50, 000 upto 75, 000 litres lit. cost of 75, 000 litres capacity job add for capacity above 75, 000 upto 1, 00, 000 litres lit. cost of 1, 00, 000 litres capacity job add for capacity above 1, 00, 000 upto 1, 50, 000 litres lit. cost of 1, 50, 000 litres capacity job add for capacity above 1, 50, 000 upto 2, 00, 000 litres lit. cost of 2, 00, 000 litres capacity job add for capacity above 2, 00, 000 upto 3, 00, 000 litres lit. cost of 3, 00, 000 litres capacity job add for capacity above 3, 00, 000 upto 5, 00, 000 litres lit. cost of 5, 00, 000 litres capacity job add for capacity above 5, 00, 000 upto 10, 00, 000 litres lit. cost of 10, 00, 000 litres capacity job addforcapacityabove10, 00, 000upto15, 00, 000 litres lit. cost of 15, 00, 000 litres capacity job add for capacity above 15, 00, 000 litres lit. note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. m1032 unconventional water treatment plant designing ( aesthetically ) , providing and constructing high rate unconventional water treatment plant i.e. simplified water treatment plant consisting of civil works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing anti termite treatment to entire structure below ground level, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanical and electrical components of various sub works as given below : including necessary hydraulic testing, structural testing and trial for 3 months, etc. complete as directed by engineer in charge ( turn key job ) works. aeration fountain inlet arrangements mixing channel with ventury flume and flow measuring arrangement inlet channel flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance rapid sand gravity filters all valve shall be glandless. filter house chemical house alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. tcl solution tank with mixing, carrying and dosing arrangement with piping. bypass arrangement external and internal electrification laboratory equipments wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. wash water pumps with 100% standby air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) . air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. pure water sump of capacity equal to 1 hour pumping capacity. pure water pump house over the sump / by the side of sump. drainage arrangements alum store sanitary block with necessary water supply and drainage arrangements and internal wbm roads. these rates are applicable for seismic zones 2, 3 and 4. rates given below are inclusive of uplift pressure if any and dewatering during the entire work. all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. unconventional treatment plants less than 1 mld capacity shall not be constructed. all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. unconventional water treatment plant fixed cost for 1 mld p.job add for capacity above 1 mld upto 2 mld p.mld cost of 2 mld treatment plant p.job add for capacity above 2 mld upto 3 mld p.mld cost of 3 mld treatment plant p.job m1033 conventional water treatment plant designing ( aesthetically ) , providing constructing and commissioning conventional water treatment plant consisting of all civil, mechanical and electrical works including cost of providing and applying epoxy paint to inside surface of water retaining structures in contact with chlorine and providing antitermite treatment to entire structure below ground level, mechanical and electrical components of various sub works as given below, including necessary hydraulic testing, structural testing, equipment testing and trial run for a period of 3 months, etc. complete as directed by engineer in charge ( turn key job ) . aeration fountain plan are a not less than 0.625 square metre per mld ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. wash water pumps capacity to fill water tank in 1 hour with 100% standby. air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . chemical house in two storeys ground floor to accommodate 7 days alum requirement and sundry storage. first floor to accommodate alum and lime tanks. etc. solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. pure water sump and sump house. capacity of sump – one hour of designed flow. pump house pump house of required size over the sump or by the side. store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. vacuum feed type chlorinators make tobe approved by mjp. conforming to i.s. 10533 a part ii 1983 rate for withdrawal temperature kg. of chlorine discharge degree c per day ( cylinders ) 45 67 tonnes 10 6.35 9.50 110 15 10.75 16.10 130 20 14.50 21.24 254 27&above 18.70 28.12 315 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 100% standby shall be provided. by pass arrangements c.i. or m.s. pipes. disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete drainage arrangements – rcc pipes up to plot boundary. electrical installation – both internal and external including entire plant area. laboratory equipment –as per requirement ( to be specified during tendering ) . sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. rates given below are inclusive of up lift pressure if any and dewatering during entire work. all pipes condutes channels with20%overloading these rates are applicable for seismic zones 2, 3 and 4. all rcc structures shall be constructed in m 300. note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . conventional water treatment plant above 3 mld to upto 5 mld p.mld cost of 5 mld treatment plant p.job add for capacity above 5mld upto 10 mld p.mld cost of 10 mld treatment plant p.job add for capacity above 10 mld upto 20 mld p.mld cost of 20 mld treatment plant p.job add for capacity above 20 mld upto 50 mld p.mld cost of 50 mld treatment plant p.job add for capacity above 50 mld upto 100 mld p.mld cost of 100 mld treatment plant p.job add for capacity above 100 mld p.mld m1034 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) 300 mm dia for gpt p / m 400 mm dia for hygpt p / m m1035 hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) from 0 50 meter p / m from 51 125 meter p / m m1036 ms pipe supplying all tools, tackles & lowering of 200 mm dia ms erw casing pipe of 6mm wall thickness including welding charges, cost of pipe etc . all complete job ( basic rates ) p / m supplying all materia;ls, labours, tools & equipments for fitting & fixing 200mm dia ms cap over casing pipe complete job ( basic rates ) item m1037 dt : basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) drillig upto 30 mtr depth below g. l. in rural area p / m drilling beyond 31 mtr upto 60 mtr below g. l. in rural area p / m m1038 trenchless installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) from 900 mm to 1000 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m from 1000 mm to 1200 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above 1200 mm to 1500 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m installation of product pipe by auger boring method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) upto 300 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above300 mm to 450 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above 450 mm to 600 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above 600 mm to 900 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m installation of product pipe by guided auger boring method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) upto 300 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above300 mm to 450 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above 450 mm to 600 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m above 600 mm to 900 mm dia in soft soil per m in hard soil per m in sandy soil per m in stone soil per m m1039 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) without byepass arrangement pn 1 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each 700 mm each 750 mm each 800 mm each 900 mm each 1000 mm each 1100 mm each 1200 mm each with byepass arrangement pn 1 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each 700 mm each 750 mm each 800 mm each 900 mm each 1000 mm each 1100 mm each 1200 mm each without byepass arrangement pn 1.6 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each with byepass arrangement pn 1.6 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . with byepass arrangement pn 1 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each 700mm each 750 mm each 800 mm each 900 mm each 1000 mm each 1100 mm each 1200mm each without byepass arrangement pn 1 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each 700mm each 750 mm each 800 mm each 900 mm each 1000 mm each 1100 mm each 1200mm each providing double flange sluice valve confirming for is 2906 / 14846 including worn gear as per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . without byepass arrangement pn 1.6 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each 700mm each 750 mm each 800 mm each 900 mm each 1000 mm each 1100 mm each 1200mm each with byepass arrangement pn 1.6 50 mm each 65 mm each 80 mm each 100 mm each 125 mm each 150 mm each 200 mm each 250 mm each 300 mm each 350 mm each 400 mm each 450 mm each 500 mm each 600 mm each m1040 design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . dia 06 inch ( 150 mm ) per m id 153 mm od 167 mm screen thickness 07 mm slot 1.00 mm moc low carbon galvenised steel length 5 mtr. dia 08 inch ( 200 mm ) per m id 205 mm od 221mm screen thickness 08 mm slot 1.00 mm moc low carbon galvenised steel length 5 mtr. dia 10 inch ( 250 mm ) per m id 256 mm od 276mm screen thickness 10 mm slot 1.00 mm moc low carbon galvenised steel length 5 mtr. dia 12 inch ( 300 mm ) per m id 306 mm od 326 mm screen thickness 10 mm slot 1.00 mm moc low carbon galvenised steel length 5 mtr. dia 14 inch ( 350 mm ) per m id 338 mm od 363 mm screen thickness 12.5 mm slot 1.00 mm moc low carbon galvenised steel length 5 mtr. m1041 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . per m m1042 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . per hrs. m1043 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . each m1044 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . each m1045 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . each m1046 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . per m m1047 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . each m1048 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818 : 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . per m m1049 supply of 200mm dia ribbed screen pipe conferming to is : 12818 : 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . per m m1050 supply of 125mm dia ribbed screen pipe conferming to is : 12818 : 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . per m m1051 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . per m m1052 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . each m1053 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . each m1054 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratory facility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. packaged lamella clarified type wtp with mgf capacity in mld...

Drinking Water And Sanitation Department - Jharkhand

32223640 e quotation for rate of materials for schedule rate jharkhand under d w and s division, gumla. e quotation for rate of materials for schedule rate jharkhand under d w and s division, gumla. , polythene water storage tank of mark (e.g sintex/sinter/himgiri / gangotietc)with cover and locking system. (m079) , gi pipe 50 mm dia (tata or equivalent make) (m193) , jute (m337) , g.m. full way valve (m924) , (i) 15 mm dia wt. not less than 300 gms without wheel , (ii) 20 mm dia wt. not less than 400 gms without wheel , (iii) 25 mm dia wt. not less than 500 gms without wheel , (iv) 32 mm dia wt. not less than 700 gms without wheel , (v) 40 mm dia wt. not less than 1.0 kg without wheel , (vi) 50 mm dia wt. not less than 1.4 kg without wheel , (vii) 65 mm dia wt. not less than 1.8 kg without wheel , (viii) 80 mm dia wt. not less than 2.5 kg without wheel , g.m. non return valve verticle (m925) , (i) 15 mm dia wt. not less than 150 gms , (ii) 20 mm dia wt. not less than 250 gms , (iii) 25 mm dia wt. not less than 375 gms , (iv) 32 mm dia wt. not less than 600 gms , (v) 40 mm dia wt. not less than 700 gms , (vi) 50 mm dia wt. not less than 1.0 kg , (vii) 65 mm dia wt. not less than 1.20 kg , (viii) 80 mm dia wt. not less than 1.50 kg , (ix) 100 mm dia wt. not less than 1.80 kg , g.m. non return valve horizontal (m926) , (i) 15 mm dia wt. not less than 150 gms , (ii) 20 mm dia wt. not less than 250 gms , (iii) 25 mm dia wt. not less than 375 gms , (iv) 32 mm dia wt. not less than 600 gms , (v) 40 mm dia wt. not less than 700 gms , (vi) 50 mm dia wt. not less than 1.0 kg , (vii) 65 mm dia wt. not less than 1.20 kg , (viii) 80 mm dia wt. not less than 1.50 kg , (ix) 100 mm dia wt. not less than 1.80 kg , cocks (m927) , (i) 15 mm dia g.m. bib cock wt. not less than 300 gms , (ii) 15 mm dia brass bib cock wt. not less than 400 gms , (iii) 15 mm dia c.i. bib cock wt. not less than 400 gms , (iv) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms , (v) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms , (vi) 15 mm c.i. plug cock ordinary , (vii) 15 mm c.i. push cock ordinary , chromium plated brass fittings (m928) , (i) c.p. shower rose 100 mm dia , (ii) c.p. shower rose 125 mm dia , (iii) p.v.c. shower rose 150 mm dia , (iv) p.v.c shower rose 125 mm dia , connection pipe (m929) , (i) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. , (ii) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. , (iii) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. , (iv) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. , g.i. fittings (conforming to i.s. 1879 ) isi marked (m930) , [a] g.i. bend , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [b] elbow of the following sizes , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [c] tee plain of the following sizes , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [d] reducing tee plain of the following sizes(taking larger dimension) , (i) 20 mm , (ii) 25 mm , (iii) 32 mm , (iv) 40 mm , (v) 50 mm , (vi) 65 mm , (vii) 80 mm , (viii) 100 mm , (ix) 125 mm , (x) 150 mm , [e] socket plain of the following size (taking larger dimension) , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [f] reducing socket plain of the following sizes (taking larger dimension) , (i) 20 mm , (ii) 25 mm , (iii) 32 mm , (iv) 40 mm , (v) 50 mm , (vi) 65 mm , (vii) 80 mm , (viii) 100 mm , (ix) 125 mm , (x) 150 mm , [g] union socket of the following sizes , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [h] plugs of the following sizes , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [i] jam nuts of the following sizes , (i) 15 mm , (ii) 20 mm , (iii) 25 mm , (iv) 32 mm , (v) 40 mm , (vi) 50 mm , (vii) 65 mm , (viii) 80 mm , (ix) 100 mm , (x) 125 mm , (xi) 150 mm , [j] g.i. nipple of the following sizes , (i) 15 mm dia x 100 mm long , (ii) 20 mm dia x 100 mm long , (iii) 25 mm dia x 100 mm long , (iv) 32mm dia x 100 mm long , (v) 40 mm dia x 100 mm long , (vi) 50 mm dia x 100 mm long , (vii) 65 mm dia x 100 mm long , (viii) 80 mm dia x 100 mm long , (ix) 100 mm dia x 100 mm long , [k] g.i. pipes midium(tata mark) or equivalent as per is 1239 (part 01)/2004 isi marked/medium quality , (i) 15 mm dia , (ii) 20 mm dia , (iii) 25 mm dia , (iv) 32 mm dia , (v) 40 mm dia , (vii) 65 mm dia , mirrors(m931) , (a) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror , (b) do 450 mm x 300 mm do , (a) glass shelf 600 mm x 125 mm with c.p. brass rail (m932) , (b) do 450 mm x 125 mm do , (a) c.p. brass towel rail 20 mm x 600 mm with bracket all complete (m933) , (b) anodized aluminum 20 mm x 600 mm towel rail complete with brackets , c.p. brass soap dish medium quality with screw andhinges etc. (m934) , c.p. liquid soap solution holder (m935) , vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make (m936) , (a) 580 mm long , (b) 510 mm long , (c) 450 mm long , (d) 510 mm long white glazed fiber i.w.c , pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make (m937) , 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket (m938) , (a) 12.5 liters lowdown c.i. cistern (m939) , (b) 10.0 liters capacity p.v.c. low design cistern , (a) white glazed vitreous e.w.c with p trap orany other equivalent make. (m940) , (b) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make , (c) black / white plastic seat for e.w.c do as above. , (a) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. (m941) , (b) do squatting small 450 mm x 350 mm , (c) do squatting large 600 mm x 350 mm , (d) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware /cera / naycer or any other equivalent make , (e) partition plate for urinal 25 x 13 size , (f) 5 liters c.i. automatic cistern with all p.v.c fittings , white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. (m942) , white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make (m943) , (a) kitchen sink 600 mm x 450 mm x 200 mm (24 x 18 x 8) , (b) kitchen sink 600 mm x 450 mm x 250 mm (24 x 18 x 10) , (c) lab sink 450 mm x 300 mm x 150 mm (18 x 12 x 6) , (d) lab sink 300 mm x 250 mm x 150 mm (12 x 10 x 6) , drain board. (m944) , (a) 600 mm x 450 mm (24 x 18) , (b) 525 mm x 450 mm (21 x 18) , h.c.i. pipes (m945) , (a) 50 mm dia single socket 6 0 (with ear weight 13 kg) , (b) 80 mm dia single socket 6 0 (with ear weight 18 kg) , (c) 100 mm dia single socket 6 0 (with ear weight 23 kg) , (d) 150 mm dia single socket 6 0 (with ear weight 30 kg) , (e) 50 mm dia double socket 6 0 (with ear weight 14 kg) , (f) 80 mm dia double socket 6 0 (with ear weight 19 kg) , (g) 100 mm dia double socket 6 0 (with ear weight 25 kg) , (h) 150 mm dia double socket 6 0 (with ear weight 13 kg) , (i) 50 mm dia single socket 3 0 (with ear weight 7.25 kg) , (j) 80 mm dia single socket 3 0 (with ear weight 10.5 kg) , (k) 100 mm dia single socket 3 0 (with ear weight 13.75 kg) , (l) 150 mm dia single socket 3 0 with ear , (m) 50 mm dia single socket 2 0 (with ear weight 5.35 kg) , (n) 80 mm dia single socket2 0 (with ear weight 8.00 kg) , (o)100 mm dia single socket 2 0(with ear weight 10.10 kg) , (p) 150 mm dia single socket 2 0 with ear , (q) 50 mm dia single socket 1 0 (with ear weight 3.4 kg) , (r) 80 mm dia single socket 1 0(with ear weight 5.50 kg) , (s) 100 mm dia single socket 1 0(with ear weight 7.60 kg) , (t) 150 mm dia single socket , h.c.i. fittings. (m946) , (i) plain bend of following size , (a) 50 mm dia (weight without ear and socket 2.75 kg) , (b) 80 mm dia (weight without ear and socket 3.5 kg) , (c) 100 mm dia (weight without ear and socket 4.5 kg) , (d) 150 mm dia (weight without ear and socket 4.5 kg) , (ii) bend with door with following size , (a) 50 mm dia (wight without ear and socket 2.75 kg) , (b) 80 mm dia (wight without ear and socket 4.00 kg) , (c) 100 mm dia do 5.5 kg , (d) 150 mm dia do , (iii) single junction with door of followings sizes. , (a) 50 mm dia (weight without ear and socket 3.75 kg) , (b) 80 mm dia (weight without ear and socket 6.50 kg) , (c) 100 mm dia do 9.50 kg , (d) 150 mm dia do , (iv) double junction with door of following sizes. , (a) 50 mm dia do 4.5 kg , (b) 80 mm dia do 7.00 kg , (c) 100 mm dia do 13.00 kg , (d) 150 mm dia do , (v) heel rest bend of following sizes , (a) 50 mm dia , (b) 80 mm dia , (c) 100 mm dia , (d) 150 mm dia , (vi) cowel of following sizes , (a) 50 mm dia (weight without ear and socket 2.25 kg) , (b) 80 mm dia (weight without ear and socket 3.25 kg) , (c) 100 mm dia (weight without ear and socket 3.25 kg) , (d) 150 mm dia do , (vii) 100 mm dia p trap (wt without ear and socket)8.5 kg , (viii) 100 mm dia p trap (wt without ear and socket)8.8 kg , (ix) 100 mm x 80 mm floor trap (weight without ear and socket) 4.00 kg , (x) pass over 50 mm x 150 mm for 50 mm projection , (xi) do 100 mm x 150 mm for 100 mm projection , (xii) inverted junction single 100 mm x 50 (weight without ear and socket) 9.0 kg , (xiii) inverted junction double 100 mm x 50 mm x 50 mm (weight without ear and socket) 12.0 kg , (xiv) h.c.i. offset 80 mm projection of the following size , (a) 50 mm dia (weight without ear and socket) 2.75 kg , (b) 80 mm dia do 3.50 kg , (c) 100 mm dia do 5.00 kg , (d) 150 mm dia do , (xv) h.c.i. socket of following sizes , (a) 50 mm dia (weight without ear) 1.50 kg , (b) 80 mm dia (weight without ear) 3.00 kg , (c) 100 mm dia (weight without ear) 4.50 kg , (d) 150 mm dia (weight without ear) do , c.i. cover with frame for manhole and inspection chamber. (m947) , (a) 600 mm x 450 mm size (wt. 39 kg) , (b) 600 mm x 450 mm size (wt. 25 kg) , (c) 500 mm x 450 mm size (wt. 25 kg) , c.i. bracket pair for w.h.b. (m948) , (a) 550 mm x 400 mm size (22 x 16) , (b) do for 12.5 liter cistern , (c) do for 600 mm x 450 mm (24 x 18) sink , (d) 40 mm x 60 mm ms plate bracket for sink as above , (a) 32 mm (1 1/4) c.p. brass waste for w.h.b (m949) , (b) 40 mm (1 1/2) c.p. brass waste for w.h.b for sink , (c) 32 mm (1 1/4) c.p. waste of white metal , (d) 40 mm (1 1/2) c.p. waste of white metal , (a) 32 mm (1 1/4) p.v.c. waste pipe 750 mm long (26 long) withbrass union for w h b (m950) , (b) 40 mm (1 1/2) p.v.c. waste pipe 750 mm long(26 long)with brass union for w h b , 32 mm (1 1/4) p.v.c. telescopic flush pipe with brass union for high level cistern (m951) , rubber inserttion 3 mm (1/8) thick (m952) , pig lead (m953) , yarn (m954) , rubber gasket for c.i pipe of good quality (m955) , (a) 80 mm , (b)100 mm , (c)125 mm , (d)150 mm , (e)200 mm , (f)250 mm , (g)300 mm , (h)350 mm , (i)400 mm , (j)450 mm , (k)500 mm , (l)600 mm , (m)700 mm , (n)750 mm , (o)800 mm , (p)900 mm , (q)1000 mm , (r)1200 mm , cotton waste (m956) , asbestos suta (gland packing) (m957) , solvent cement (m958) , hydrocloric acid (sepecific gravity 1.20) (m959) , cp & pvc fitting (m960) , (i)32 mm dia c.p. waste , (ii)32 mm dia pv c waste pipe 750 mm long with coupling , (iii)40 mm dia c.p. waste , (iv 40 mm dia pvc waste pipe 750 mm long with coupling , (v 100 mm dia steel jali , (vi)15 mm dia c.p. nipple with coupling (short pieces) , (vii)50 mm dia pvc pipe with coupling , special type of c.p. bath room fittings for v.i.p.buildings(jal, jaquar, marc or equivalent mark) (m961) , (i) pillar cock (isi) , (ii) pillar cock (long neck) , (iii) bib cock (isi) , (iv) bib cock (long thread) , (v) angular stop cock , (vi) angular stop cock (long thread) , (vii) concealed stop cock reduce (isi) , (viii) concealed stop cock heavy duty extra adjustable wall flange , (ix) long body bib cock , (x) swan neck tap with left hand operating knob , (xi) central hole basin mixer (best quality) , (xii) wall mixer with telephonic shower arrangement , (xiii) wall mixer with provision for over head shower with elbow coupling and well flange , (xiv) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange , (xv) sink mixer with swinging casted spout , (xvi) sink cock with swinging casted spout , (xvii) 4 way diverter for concealed fittings , (xviii) pressure adjustable shower with revolving joint , (xix) telephone shower with flexible pipe , (xx) flush cock with wall flange (25 mm) , (xxi) towel rail 24 , (xxii) towel ring , (xxiii) soap dish , (xxiv) tumbler holder , (xxv) toilet paper holder , (xxvi) glass shelf 22 , (xxvii) corner glass shelf with bracket , (xxviii) flush valve complete with 32 mm size controlcock & flange , c.i special & pvc pipes (m962) , 1. c.i double shocketted fittings bend such as bend, tee, taper, , (a) 80 200 mm , (b) 250 700 mm , (c) 700 1000 mm , 2. c.i double flange fittings such as tee, taper, tailpiece,bend etc , (a) 80 200 mm , (b) 250 700 mm , (c) 700 1000 mm , basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818/2016 cml no. 5543459 (m1024) , installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation ,shoring/strutting etc shielded excavation ,through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) , above 600 mm to 900 mm dia , in soft soil , in hard soil , in sandy soil , in stone soil , providing and supplying isi mark ci/ d/f reflux valves( non return valves ) of following dia inspection charges unloading from railway wagon ,loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i (1984) (m1039) , without byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700 mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200 mm , with byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700 mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200 mm , without byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , with byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . , with byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , without byepass arrangement pn 1 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . , without byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , 700mm , 750 mm , 800 mm , 900 mm , 1000 mm , 1100 mm , 1200mm , with byepass arrangement pn 1.6 , 50 mm , 65 mm , 80 mm , 100 mm , 125 mm , 150 mm , 200 mm , 250 mm , 300 mm , 350 mm , 400 mm , 450 mm , 500 mm , 600 mm , supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site(basic rate). (m1041) , supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e/i (basic rate). (m1042) , supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e/i (basic rate). (m1043) , supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e/i (the cap will be the property of department) (basic rate). (m1044) , supplying all materials, labours, equipments for constructing p.c.c. (1:2:4) circular platform around drilled tube well including 12mm thick cement plaster (1:4) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials (basic rate). (m1045) , supplying all materials, labours and equipments for constructing p.c.c. (1:2:4) drain as per unicef design etc. all complete including carriage of materials (basic rate). (m1046) , supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod (12 pcs) as per is : 15500 part 2/2004(basic rate). (m1047) , supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 (cml no. 5543459) latest revision including carrigae(basic rate). (m1048) , supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 (cml no. 5543459) latest revision including carrigae(basic rate). (m1049) , supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 (cml no. 5543459) latest revision including carrigae(basic rate). (m1050) , supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e/i including carriage of materials (basic rate). (m1051) , supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e/i including carriage of materials (basic rate). (m1052) , supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e/i including carriage of materials(basic rate). (m1053) , design, supply, installation testing & commissioning of packaged water treatment plants (unconventional type) of different capacity with (20 hours operation) comprising of lamella clarifier, static mixture flocculation tank (smet), multi grade filter (mgf) with best quality filter media, lime/ coagulant/polymer dosing system hypo chloride dosing system, raw water feed pump/clear water transfer pump (either or), sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer/ authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure/items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. (m1054) , packaged lamella clarified type wtp with mgf capacity in mld. , (i)0.2 , (ii)0.3 , (iii)0.4 , (iv)0.5 , (v)0.6...

Drinking Water And Sanitation Department - Jharkhand

32223632 e quotation for rate of materials for schedule rate jharkhand under d w and s division, medininagar 2022 23. 1 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) 2 gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) 3 jute ( m337 ) 4 g.m. ferrules ( m922 ) 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 stop cocks ( m923 ) 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 g.m. full way valve ( m924 ) 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 g.m. non return valve verticle ( m925 ) 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 g.m. non return valve horizontal ( m926 ) 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 cocks ( m927 ) 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 chromium plated brass fittings ( m928 ) 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 connection pipe ( m929 ) 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 mirrors ( m931 ) 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) 194 ( b ) do 450 mm x 125 mm do 195 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) 198 c.p. liquid soap solution holder ( m935 ) 199 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) 205 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) 206 ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) 218 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 drain board. ( m944 ) 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 h.c.i. pipes ( m945 ) 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 h.c.i. fittings. ( m946 ) 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 c.i. cover with frame for manhole and inspection chamber. ( m947 ) 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 c.i. bracket pair for w.h.b. ( m948 ) 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) 311 rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) 312 pig lead ( m953 ) 313 yarn ( m954 ) 314 rubber gasket for c.i pipe of good quality ( m955 ) 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 cotton waste ( m956 ) 334 asbestos suta ( gland packing ) ( m957 ) 335 solvent cement ( m958 ) 336 hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) 337 cp & pvc fitting ( m960 ) 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 c.i special & pvc pipes ( m962 ) 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) 385 rcc esr ( m1030 ) 386 designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. 387 notes 388 the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) 389 the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. 390 for design having more than 6 columns, suitable bracing is obligatory. 391 plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed 392 irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 393 these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. 394 staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 395 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 396 all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 397 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 398 the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . 399 for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. 400 below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. 401 the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. 402 the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 403 12 to 16 m staging 2% per metre 404 16 to 20 m staging 3% per metre 405 20 m and above 4% per metre 406 for 17 m staging height, percentage calculation will be like below : 407 12 to 16 m 4 x 2 = 8% 408 16 & 17 m 1 x 3% = 3% total = 11% 409 for 21 m staging height, percentage calculation will be like below : 410 12 to 16 m 4 x 2 = 8% 411 16 to 20 m 4 x 3% = 12% 412 20& 21 m 1 x 4% = 4% total = 24% 413 following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . 414 notes 415 conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. 416 conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. 417 rates for rcc esrs 418 upto 25, 000 litres 419 cost of 25, 000 litres capacity 420 add for capacity above 25, 000 upto 50, 000 litres 421 cost of 50, 000 litres capacity 422 add for capacity above 50, 000 upto 75, 000 litres 423 cost of 75, 000 litres capacity 424 add for capacity above 75, 000 upto 1, 00, 000 litres 425 cost of 1, 00, 000 litres capacity 426 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 427 cost of 1, 50, 000 litres capacity 428 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 429 cost of 2, 00, 000 litres capacity 430 add for capacity above 2, 00, 000 upto 2, 50, 000 litres 431 cost of 2, 50, 000 litres capacity 432 add for capacity above 2, 50, 000 upto 3, 00, 000 litres 433 cost of 3, 00, 000 litres capacity 434 add for capacity above 3, 00, 000 upto 4, 00, 000 litres 435 cost of 4, 00, 000 litres capacity 436 add for capacity above 4, 00, 000 upto 5, 00, 000 litres 437 cost of 5, 00, 000 litres capacity 438 add for capacity above 5, 00, 000 upto 7, 50, 000 litres 439 cost of 7, 50, 000 litres capacity 440 add for capacity above 7, 50, 000 upto 10, 00, 000 litres 441 cost of 10, 00, 000 litres capacity 442 add for capacity above 10, 00, 000 upto 15, 00, 000 litres 443 cost of 15, 00, 000 litres capacity 444 add for capacity above 15, 00, 000 upto 20, 00, 000 litres 445 cost of 20, 00, 000 litres capacity 446 rcc gsr and sump ( m1031 ) 447 designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. 448 anti –termite treatment shall be given for under ground portion of the structure. 449 notes 450 the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) 451 only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. 452 entire structure shall be in m 300 only. 453 the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 454 the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. 455 the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. 456 g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. 457 for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. 458 cost of pump house is not included in these rates. 459 above rates are applicable for seismic zones 2, 3 and 4. 460 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 461 10% shall be added for sump if over head pump house is proposed. 462 note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. 463 rates for rcc gsrs and sumps 464 upto 25, 000 litres 465 cost of 25, 000 litres capacity 466 add for capacity above 25, 000 upto 50, 000 litres 467 cost of 50, 000 litres capacity 468 add for capacity above 50, 000 upto 75, 000 litres 469 cost of 75, 000 litres capacity 470 add for capacity above 75, 000 upto 1, 00, 000 litres 471 cost of 1, 00, 000 litres capacity 472 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 473 cost of 1, 50, 000 litres capacity 474 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 475 cost of 2, 00, 000 litres capacity 476 add for capacity above 2, 00, 000 upto 3, 00, 000 litres 477 cost of 3, 00, 000 litres capacity 478 add for capacity above 3, 00, 000 upto 5, 00, 000 litres 479 cost of 5, 00, 000 litres capacity 480 add for capacity above 5, 00, 000 upto 10, 00, 000 litres 481 cost of 10, 00, 000 litres capacity 482 addforcapacityabove10, 00, 000upto15, 00, 000 litres 483 cost of 15, 00, 000 litres capacity 484 add for capacity above 15, 00, 000 litres 485 note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. 486 unconventionalwater treatment plant ( m1032 ) 487 designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. 488 aeration fountain 489 inlet arrangements 490 mixing channel with ventury flume and flow measuring arrangement 491 inlet channel 492 flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes 493 tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance 494 rapid sand gravity filters all valve shall be glandless. 495 filter house 496 chemical house 497 alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 498 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. 499 tcl solution tank with mixing, carrying and dosing arrangement with piping. 500 bypass arrangement 501 external and internal electrification 502 laboratory equipments 503 wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. 504 wash water pumps with 100% standby 505 air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. 506 pure water sump of capacity equal to 1 hourpumping capacity. 507 pure water pump house over the sump / by the side of sump. 508 drainage arrangements 509 alum store 510 sanitary block with necessary water supply and drainage arrangements and internalwbm roads. 511 these rates are applicable for seismic zones 2, 3 and 4. 512 rates given below are inclusive of uplift pressure if any and dewatering during the entire work. 513 all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. 514 unconventional treatment plants less than 1 mld capacity shall not be constructed. 515 all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . 516 note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. 517 unconventional water treatment plant 518 fixed cost for 1 mld 519 add for capacity above 1 mld upto 2 mld 520 cost of 2 mld treatment plant 521 add for capacity above 2 mld upto 3 mld 522 cost of 3 mld treatment plant 523 conventionalwater treatment plant ( m1033 ) 524 designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . 525 aeration fountain plan are a not less than 0.625 square metre per mld 526 ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) 527 flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. 528 flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. 529 clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. 530 rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. 531 filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. 532 wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. 533 wash water pumps capacity to fill water tank in 1 hour with 100% standby. 534 air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . 535 chemical house in two storeys 536 ground floor to accommodate 7 days alum requirement and sundry storage. 537 first floor to accommodate alum and lime tanks.etc. 538 solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. 539 pure water sump and sump house. 540 capacity of sump – one hour of designed flow. 541 pump house pump house of required size over the sump or by the side. 542 store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. 543 vacuum feed type chlorinators make tobe approved by mjp. 544 conforming to i.s. 10533 a part ii 1983 545 rate for withdrawal 546 temperature kg. of chlorine discharge degree c per day ( cylinders ) 547 45 67 tonnes 548 10 6.359.50 110 549 15 10.75 16.10130 550 20 14.50 21.24254 551 27&above18.70 28.12315 552 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 553 100% standby shall be provided. 554 by pass arrangements c.i. or m.s. pipes. 555 disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe 556 for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete 557 drainage arrangements – rcc pipes up to plot boundary. 558 electrical installation – both internal and external including entire plant area. 559 laboratory equipment –as per requirement ( to be specified during tendering ) . 560 sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. 561 administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. 562 rates given below are inclusive of up lift pressure if any and dewatering during entire work. 563 all pipes condutes channels with20%overloading 564 these rates are applicable for seismic zones 2, 3 and 4. 565 all rcc structures shall be constructed in m 300. 566 note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . 567 conventional water treatment plant 568 above3 mld to upto 5 mld 569 cost of 5 mld treatment plant 570 add for capacity above 5mld upto 10 mld 571 cost of 10 mld treatment plant 572 add for capacity above 10 mld upto20 mld 573 cost of 20 mld treatment plant 574 add for capacity above 20 mld upto 50 mld 575 cost of 50 mld treatment plant 576 add for capacityabove 50 mld upto 100 mld 577 cost of 100 mld treatment plant 578 add for capacity above 100 mld 579 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) 580 300 mm dia for gpt 581 400 mm dia for hygpt 582 hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) 583 from 0 50 meter 584 from 51 125 meter 585 dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) 586 drillig upto 30 mtr depth below g. l. in rural area 587 drilling beyond 31 mtr upto 60 mtr below g. l. in rural area 588 trenchless ( m1038 ) 589 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 590 from 900 mm to 1000 mm dia 591 in soft soil 592 in hard soil 593 in sandy soil 594 in stone soil 595 from 1000 mm to 1200 mm dia 596 in soft soil 597 in hard soil 598 in sandy soil 599 in stone soil 600 above 1200 mm to 1500 mm dia 601 in soft soil 602 in hard soil 603 in sandy soil 604 in stone soil 605 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 606 upto 300 mm dia 607 in soft soil 608 in hard soil 609 in sandy soil 610 in stone soil 611 above300 mm to 450 mm dia 612 in soft soil 613 in hard soil 614 in sandy soil 615 in stone soil 616 above 450 mm to 600 mm dia 617 in soft soil 618 in hard soil 619 in sandy soil 620 in stone soil 621 above 600 mm to 900 mm dia 622 in soft soil 623 in hard soil 624 in sandy soil 625 in stone soil 626 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 627 upto 300 mm dia 628 in soft soil 629 in hard soil 630 in sandy soil 631 in stone soil 632 above300 mm to 450 mm dia 633 in soft soil 634 in hard soil 635 in sandy soil 636 in stone soil 637 above 450 mm to 600 mm dia 638 in soft soil 639 in hard soil 640 in sandy soil 641 in stone soil 642 above 600 mm to 900 mm dia 643 in soft soil 644 in hard soil 645 in sandy soil 646 in stone soil 647 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) 648 without byepass arrangement pn 1 649 50 mm 650 65 mm 651 80 mm 652 100 mm 653 125 mm 654 150 mm 655 200 mm 656 250 mm 657 300 mm 658 350 mm 659 400 mm 660 450 mm 661 500 mm 662 600 mm 663 700 mm 664 750 mm 665 800 mm 666 900 mm 667 1000 mm 668 1100 mm 669 1200 mm 670 with byepass arrangement pn 1 671 50 mm 672 65 mm 673 80 mm 674 100 mm 675 125 mm 676 150 mm 677 200 mm 678 250 mm 679 300 mm 680 350 mm 681 400 mm 682 450 mm 683 500 mm 684 600 mm 685 700 mm 686 750 mm 687 800 mm 688 900 mm 689 1000 mm 690 1100 mm 691 1200 mm 692 without byepass arrangement pn 1.6 693 50 mm 694 65 mm 695 80 mm 696 100 mm 697 125 mm 698 150 mm 699 200 mm 700 250 mm 701 300 mm 702 350 mm 703 400 mm 704 450 mm 705 500 mm 706 600 mm 707 with byepass arrangement pn 1.6 708 50 mm 709 65 mm 710 80 mm 711 100 mm 712 125 mm 713 150 mm 714 200 mm 715 250 mm 716 300 mm 717 350 mm 718 400 mm 719 450 mm 720 500 mm 721 600 mm 722 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 723 with byepass arrangement pn 1 724 50 mm 725 65 mm 726 80 mm 727 100 mm 728 125 mm 729 150 mm 730 200 mm 731 250 mm 732 300 mm 733 350 mm 734 400 mm 735 450 mm 736 500 mm 737 600 mm 738 700mm 739 750 mm 740 800 mm 741 900 mm 742 1000 mm 743 1100 mm 744 1200mm 745 without byepass arrangement pn 1 746 50 mm 747 65 mm 748 80 mm 749 100 mm 750 125 mm 751 150 mm 752 200 mm 753 250 mm 754 300 mm 755 350 mm 756 400 mm 757 450 mm 758 500 mm 759 600 mm 760 700mm 761 750 mm 762 800 mm 763 900 mm 764 1000 mm 765 1100 mm 766 1200mm 767 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 768 without byepass arrangement pn 1.6 769 50 mm 770 65 mm 771 80 mm 772 100 mm 773 125 mm 774 150 mm 775 200 mm 776 250 mm 777 300 mm 778 350 mm 779 400 mm 780 450 mm 781 500 mm 782 600 mm 783 700mm 784 750 mm 785 800 mm 786 900 mm 787 1000 mm 788 1100 mm 789 1200mm 790 with byepass arrangement pn 1.6 791 50 mm 792 65 mm 793 80 mm 794 100 mm 795 125 mm 796 150 mm 797 200 mm 798 250 mm 799 300 mm 800 350 mm 801 400 mm 802 450 mm 803 500 mm 804 600 mm 805 design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . ( m1040 ) 806 dia 06 inch ( 150 mm ) 807 id 153 mm od 167 mm 808 screen thickness 07 mm 809 slot 1.00 mm 810 moc lowcarbon galvenised steel 811 length 5 mtr. 812 dia 08 inch ( 200 mm ) 813 id 205 mm od 221mm 814 screen thickness 08 mm 815 slot 1.00 mm 816 moc lowcarbon galvenised steel 817 length 5 mtr. 818 dia 10 inch ( 250 mm ) 819 id 256 mm od 276mm 820 screen thickness 10 mm 821 slot 1.00 mm 822 moc lowcarbon galvenised steel 823 length 5 mtr. 824 dia 12 inch ( 300 mm ) 825 id 306 mm od 326 mm 826 screen thickness 10 mm 827 slot 1.00 mm 828 moc lowcarbon galvenised steel 829 length 5 mtr. 830 dia 14 inch ( 350 mm ) 831 id 338 mm od 363 mm 832 screen thickness 12.5 mm 833 slot 1.00 mm 834 moc lowcarbon galvenised steel 835 length 5 mtr. 836 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) 837 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) 838 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) 839 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) 840 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) 841 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) 842 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) 843 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) 844 supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) 845 supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) 846 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) 847 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) 848 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) 849 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) 850 packaged lamella clarified type wtp with mgf capacity in mld. 851 0.2 852 0.3 853 0.4 854 0.5 855 0.6 856 pumps ( m1055 ) 857 supplying100 mm dia submersible pump sets confirming to is 8034 and motor confirming to is 9283. pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene / noryl impeller. motor suitable for working on 415v+10%, 3ph, 50 hz, a.c. supply with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. pump shall have suitable outlet as per manufacturers design. anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump. 858 submersible pump set 100 mm dia ( with polypropylene / noryl impeller ) up to 20 stages 859 1 h.p. 860 1.5hp 861 2 hp 862 2.5 hp 863 3.0 hp 864 4.0 hp 865 5.0 hp 866 supply rate should be increased by rs 200 / per stage for pump with more than 20 stages 867 submersible pump 150 mm dia ( with bronze impeller ) up to 8 stages 868 1.5 hp 869 2.0 hp 870 3.0 hp 871 4.0 hp 872 5.0 hp 873 6.0 hp 874 7.5 hp 875 supply rate should be increased by rs 600 / per stage for pump with more than 8 stages 876 submersible pump 150 mm dia ( with bronze impeller ) up to 12 stages 877 8.0 hp 878 9.0 hp 879 10.0 hp 880 11.0 hp 881 12.5 hp 882 15.0 hp 883 supply rate should be increased by rs 600 / per stage for pump with more than 12 stages 884 submersible pump 150 mm dia ( with bronze impeller ) up to 20 stages 885 17.5 hp 886 20.0 hp 887 25 hp 888 1 ) supply rate should be increased by rs 600 / per stage for pump with more than 20 stages for bore well only. 889 for other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump. 890 2 ) for 150 mm dia energy efficient pumps add as below 891 a. up to 8 stages : 3% on supply rate 892 b. up to 12 stages : 4% on supply rate 893 c. up to 15 stages : 5% on supply rate 894 pressure gauge ( m1056 ) 895 providing fabricating, testing and commisioning pressure vessel fabricating in m.s plate on providing foundation including epoxy paint 896 pressure gauge ( 100 mm dia ) 897 pressure gauge ( 150 mm dia ) 898 vacuum / combination gauge 899 supplyingvacuum gauge / combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia g.i. pipe. 900 vacuum / combination gauge – 100 mm dia 901 vacuum / combination gauge – 150 mm dia 902 lifting equipment ( m1057 ) 903 chain pulley block 904 supplyingtriple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 905 1 tonne capacity 906 2 tonne capacity 907 3 tonne capacity 908 hand operated circular or rectangular travelling crane ( single girder ) 909 supplyingsingle girder hand operated circular / rectangular travelling crane with 6 m lift complete with chain pulley block isi marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete. 910 3 tonne capacity 911 up to 5 m span 912 above 5 m up to 6 m span 913 above 6 m up to 8 m span 914 5 tonne capacity 915 up to 5 m span 916 above 5 m up to 6 m span 917 above 6 m up to 8 m span 918 above 8 m up to 10 m span 919 electric operated circular or rectangular travelling crane ( single girder ) 920 supplying single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class ii duty, all three motions electrically operated by suitable rating motor ip 54, control panel and down pendant control block. 921 5 tonne capacity 922 above 6 m up to 8 m span 923 above 8 m up to 10 m span 924 7.5 tonne capacity 925 above 6 m upto 8 m span 926 above 8 m up to 10 m span 927 10 tonne capacity 928 above 6 m up to 8 m span 929 above 8 m up to 10 m span 930 square bar / rail 931 providing, erecting and fixing square bar of en 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and “j” bolts. 932 50 x 50 mm ( en 8 ) 933 40 x 40 mm ( en 8 ) 934 lightening arrester, ab switch, insulators ( m1058 ) 935 lightening arrestor 936 supplying, erecting approved make thyrite type lightening arrestor suitable for h.t. supply with necessary ancillary material complete on provided cross arm and connected to overhead line. 937 suitable for 11 kv supply, distribution class 938 suitable for 22 kv supply, distribution class 939 suitable for 33 kv supply, station class 940 disc insulator 941 supplying, erecting porcelain disc type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 942 suitable for 11kv line 943 suitable for 33kv line 944 pin insulator 945 supplying, erecting porcelain pin type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 946 suitable for 11kv line 947 suitable for 33kv line 948 air break switch without earth switch 949 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 950 suitable for 11kv line 951 rocking / tilting type 952 rotating type 953 suitable for 33kv line 954 rocking / tilting type 955 rotating type 956 air break switch with earth switch 957 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 958 suitable for 11kv line 959 rotating type 960 suitable for 33kv line 961 rotating type 962 drop out fuse ( channel mounted ) 963 supplying, erecting approved make out door type drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working currentup to 50 amp, capacity completeerected on provided cross arm, each set comprising 3 units 964 suitable for 11 kv line 965 suitable for 33 kv line 966 horn gap fuse ( channel mounted ) 967 supplying, erecting approved make out door type horn gap type fuse with insulator, fuse element, with working current up to 50 amp, capacity complete erected on provided cross arm, each set comprising 3 units 968 suitable for 11 kv line 969 suitable for 33 kv line 970 transformer ( m1059 ) 971 power transformer ( with off load tap changer ) any isi mark 972 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 973 1. oil conservator with filling hole with cap and plain oil level gauge. 974 2. silica gel dehydrating breather charged with silica gel. 975 3. oil drain valve 976 4. oil filter valve 977 5. lifting eyes / hooks 978 6. two earthing terminals 979 7. diagram and rating plate 980 8. air vent 981 9. explosion vent 982 10. 100mm dia thermo meter with thermometer pocket 983 11. four bi directional plain roller. 984 power transformer 11000 / 433 volts with off load tap changer – 12.5% to +2.5% in steps of 2.5% as per bis level 2. 985 63 kva ( no load loss 180w and load loss 1235w ) 986 100 kva ( no load loss 260w and load loss 1760w ) 987 160kva ( no load loss 260w and load loss 1760w ) 988 200kva ( no load loss 500w and load loss3000w ) 989 250kvaa ( no load loss 550w and load loss3600w ) 990 315kva ( no load loss 580w and load loss 4200w ) 991 400 kva ( no load loss 715w and load loss 5000w ) 992 500 kva ( no load loss 850w and load loss 5800w ) 993 630 kva ( no load loss 1000w and load loss 7000w ) 994 750 kva ( no load loss 1500w and load loss 8000w ) 995 power transformer ( with on load tap changer ) 996 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. the oltc should be suitable for minimum 50 operations per day. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 997 1. oil conservator with filling hole with cap and plain oil level gauge. 998 2. silica gel dehydrating breather charged with silica gel. 999 3. oil drain valve 1000 4. oil filter valve 1001 5. lifting eyes / hooks 1002 6. two earthing terminals 1003 7. diagram and rating plate 1004 8. air vent 1005 9. explosion vent 1006 10. 100mm dia thermo meter with thermometer pocket 1007 11. four bi directional plain roller. 1008 12. buchholz relay 1009 13. resistance temp. detector 1010 14. marshalling box 1011 15. automatic voltage regulator ( avr ) 1012 16. remote tap changing controller ( rtcc ) 1013 transformer 11000 / 433 volts withon load tap changer – 15% to +5% in steps of 1.25% with rtcc, avr and marshalling box and other specification as per bis level 2. 1014 750 kva 1015 1000 kva 1016 1250 kva 1017 1600 kva 1018 2000 kva 1019 motors ( m1060 ) 1020 foot mounted motors tefc 1500 rpm 1021 supplyingfoot mounted tefc 1500 rpm, squirrel cage induction motor, conforming to is 325 having continuous rating suitable for operation at 415 volts + / 10%, 3 phase, 50 hz + / 3% with “f” class insulation temperature rise limited to class “b” insulation. motors conform to is 12615 with efficiency level ie3 and provided with enclosure protection class ip 55. 1022 15 kw ( 20 hp ) 1023 18.5 kw ( 25 hp ) 1024 22 kw ( 30 hp ) 1025 30 kw ( 40 hp ) 1026 37 kw ( 50 hp ) 1027 45 kw ( 60 hp ) 1028 55 kw ( 75 hp ) 1029 75 kw ( 100 hp ) 1030 90 kw ( 120 hp ) 1031 110 kw ( 150 hp ) 1032 132kw ( 180hp ) 1033 160kw ( 215 hp ) 1034 250kw ( 335 hp ) 1035 foot mounted motor tefc 1500 rpm 1036 0.75 kw ( 1hp ) 1037 1.1 kw ( 1.5 hp ) 1038 1.5 kw ( 2 hp ) 1039 2.2 kw ( 3 hp ) 1040 3.7 kw ( 5 hp ) 1041 5.5 kw ( 7.5 hp ) 1042 7.5 kw ( 10 hp ) 1043 9.3 kw ( 12.5 hp ) 1044 11 kw ( 15 hp ) 1045 aluminium cable ( m1061 ) 1046 cable 1047 aluminium conductor three core, xlpe / pvc insulated & armoured cable . 1048 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1049 3 core 2.5 sq mm 1050 3 core 4 sq mm 1051 3 core 6 sq mm 1052 3 core 10 sq mm 1053 3 core 16 sq mm 1054 3 core 25 sq mm 1055 3 core 35 sq mm 1056 3 core 50 sq mm 1057 3 core 70 sq mm 1058 3 core 95 sq mm 1059 3 core 120 sq mm 1060 3 core 150 sq mm 1061 3 core 185 sq mm 1062 3 core 240 sq mm 1063 3 core 300 sq mm 1064 3 core 400 sq mm 1065 aluminium conductor 3.5 core, xlpe / pvc insulated & unarmoured cable 1066 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three and half core, stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1067 3.5 core 25 sq mm 1068 3.5 core 35 sq mm 1069 3.5 core 50 sq mm 1070 3.5 core 70 sq mm 1071 3.5 core 95 sq mm 1072 3.5 core 120 sq mm 1073 3.5 core 150 sq mm 1074 3.5 core 185 sq mm 1075 3.5 core 240 sq mm 1076 3.5 core 300 sq mm 1077 3.5 core 400 sq mm 1078 ht aluminium three core 3.3 kve cable xlpe insulated 1079 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1080 3 core 35 sq mm 1081 3 core 50 sq mm 1082 3 core 70 sq mm 1083 3 core 95 sq mm 1084 3 core 120 sq mm 1085 3 core150sq mm 1086 3 core 185 sq mm 1087 3 core 240sq mm 1088 3 core 300 sq mm 1089 3 core 400 sq mm 1090 ht aluminium three core 6.6 kv ( ue ) / 11kv ecable xlpe insulated 1091 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1092 3 core 35 sq mm 1093 3 core 50 sq mm 1094 3 core 70 sq mm 1095 3 core 95 sq mm 1096 3 core 120 sq mm 1097 3 core150sq mm 1098 3 core 185 sq mm 1099 3 core 240sq mm 1100 3 core 300 sq mm 1101 3 core 400 sq mm 1102 ht aluminium three core 11kv ( ue ) cable xlpe insulated 1103 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1104 3 core 35 sq mm 1105 3 core 50 sq mm 1106 3 core 70 sq mm 1107 3 core 95 sq mm 1108 3 core 120 sq mm 1109 3 core150sq mm 1110 3 core 185 sq mm 1111 3 core 240sq mm 1112 3 core 300 sq mm 1113 3 core 400 sq mm 1114 aluminium conductor three core, xlpe / pvc insulated & unarmoured cable . 1115 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1116 3 core 4 sq mm 1117 3 core 6 sq mm 1118 3 core 10 sq mm 1119 3 core 16 sq mm 1120 3 core 25 sq mm 1121 3 core 35 sq mm 1122 3 core 50 sq mm 1123 3 core 70 sq mm 1124 3 core 95 sq mm 1125 3 core 120 sq mm 1126 3 core 150 sq mm 1127 3 core 185 sq mm 1128 3 core 240 sq mm 1129 3 core 300 sq mm 1130 3 core 400 sq mm 1131 copper cable ( m1062 ) 1132 cable 1133 3 core pvc insulated, pvc sheathed copper conductor flat submersible cable . 1134 supplying , flat flexible submersible cable with, copper conductor, pvc insulated, and pvc sheathed . 1135 3 core 1.5 sq mm 1136 3 core 2.5 sq mm 1137 3 core 4 sq mm 1138 3 core 6 sq mm 1139 3 core 10 sq mm 1140 3 core 16 sq mm 1141 3 core 25 sq mm 1142 3 core 35 sq mm 1143 copper conductor three core, xlpe / pvc insulated & unarmoured cable . 1144 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1145 3 core 1.5 sq mm 1146 3 core 2.5 sq mm 1147 3 core 4 sq mm 1148 3 core 6 sq mm 1149 3 core 10 sq mm 1150 3 core 16 sq mm 1151 3 core 25 sq mm 1152 3 core 35 sq mm 1153 3 core 50 sq mm 1154 3 core 70 sq mm 1155 3 core 95 sq mm 1156 copper conductor 3.5 core, xlpe / pvc insulated & armoured cable . 1157 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1158 3.5 core 1.5 sq mm 1159 3.5 core 2.5 sq mm 1160 3.5 core 4 sq mm 1161 3.5 core 6 sq mm 1162 3.5 core 10 sq mm 1163 3.5 core 16 sq mm 1164 3.5 core 25 sq mm 1165 3.5 core 35 sq mm 1166 3.5 core 50 sq mm 1167 3 .5 core 70 sq mm 1168 3.5 core 95 sq mm 1169 3.5 core 120 sq mm 1170 3 .5 core150sq mm 1171 3.5 core 185 sq mm 1172 3.5 core 240sq mm 1173 3.5 core 300 sq mm 1174 3.5 core 400 sq mm 1175 copper conductor 3.5 core xlpe / pvcunarmoured 1176 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1177 3.5core 25 sq mm 1178 3.5core 35 sq mm 1179 3.5 core 50 sq mm 1180 3.5 core 70 sq mm 1181 3.5 core 95 sq mm 1182 3.5 core 120 sq mm 1183 3.5 core150sq mm 1184 3.5 core 185 sq mm 1185 3.5 core 240sq mm 1186 3.5 core 300 sq mm 1187 3.5 core 400 sq mm 1188 copper conductor three core, xlpe / pvc insulated & armoured cable . 1189 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1190 3 core 1.5 sq mm 1191 3 core 2.5 sq mm 1192 3 core 4 sq mm 1193 3 core 6 sq mm 1194 3 core 10 sq mm 1195 3 core 16 sq mm 1196 3 core 25 sq mm 1197 3 core 35 sq mm 1198 3 core 50 sq mm 1199 3 core 70 sq mm 1200 3 core 95 sq mm 1201 3 core 120 sq mm 1202 3 core 150sq mm 1203 3core 185 sq mm 1204 3 core 240 sq mm 1205 3 core 300 sq mm 1206 3 core 400 sq mm 1207 foot valve ( m1063 ) 1208 foot valve 1209 supplying c.i. foot valve having single leather flap and gunmetal seating. valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. 1210 flanged type 1211 50 mm 1212 65 mm 1213 80 mm 1214 100 mm 1215 125 mm 1216 150 mm 1217 aircircuit breaker ( m1064 ) 1218 acbbreaking capacity 50ka thermal magnetic manual draw out type 3 pole 1219 630a 1220 800a 1221 1000a 1222 1250a 1223 1600a 1224 2000a 1225 starter ( m1065 ) 1226 d.o.l. starter with ss enclosure with 380 / 415 volt coil 1227 7.5 h.p. 1228 10 h.p. 1229 supplyingfully automatic star delta starter to operate induction motor working on415v, 3phase, 50 hz with no volt coil, over load element, on off push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser 1230 f.a.s.d starter 1231 10.0 h.p. 1232 15 h.p. 1233 20 h.p. 1234 25 h.p. 1235 35 h.p. 1236 40 hp 1237 50 hp 1238 75 h.p. 1239 100 h.p. 1240 125 h.p. 1241 150 h.p. 1242 250 h.p. 1243 servo controlled automatic voltage stabilizer ( m1066 ) 1244 providing, erecting servo controlled automatic voltage stabiliser suitable for out put voltage of 415 volt + / 1%, 3 ph, 50 hz, with copper wound transformer ( air / oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, auto / manual selector switch, raise / low push buttons etc. suitable capacity termination strips and bus bars for incoming and out going cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated 􀂌 over voltage / under voltage 􀂌 single phasing 􀂌 cut off contactor with electronic output sensing unit 1245 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 150 to 450 volt 1246 20 kva air cooled 1247 25 kva air cooled 1248 30 kva air cooled 1249 40 kva air cooled 1250 50 kva oil cooled 1251 60 kva oil cooled 1252 75 kva oil cooled 1253 100 kva oil cooled 1254 125 kva oil cooled 1255 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 280 to 460 volt 1256 15 kva air cooled 1257 20 kva air cooled 1258 25 kva air cooled 1259 30 kva air cooled 1260 40 kva air cooled 1261 50kva air cooled 1262 60 kva oil cooled 1263 75kva oil cooled 1264 100 kva oil cooled 1265 125 kva oil cooled 1266 150 kva oil cooled 1267 200kva oil cooled 1268 250kva oil cooled 1269 300 kva oil cooled 1270 400 kva oil cooled 1271 termination kit ( m1067 ) 1272 providing and errecting in door type termination kit, for 3.3kv / 6.6 kv / 11kv / 22kv / 33kv xlpe screened 3 core cable 1273 in door termination kit for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1274 25 50 mm2 1275 70 120 mm2 1276 150 185 mm2 1277 240 400 mm2 1278 out door termination kit for 3.3 ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1279 25 50 mm2 1280 70 120 mm2 1281 150 185 mm2 1282 240 400 mm2 1283 straight through joint for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1284 25 50 mm2 1285 70 120 mm2 1286 150 185 mm2 1287 240 300 mm2 1288 in door termination kit for 11kv ( e ) xlpe screened 3 core cable 1289 25 50 mm2 1290 70 120 mm2 1291 150 185 mm2 1292 240 400 mm2 1293 out door termination kit for 11kv ( e ) xlpe screened 3 core cable 1294 25 50 mm2 1295 70 120 mm2 1296 150 185 mm2 1297 240 400 mm2 1298 straight through joint for 11 kv ( e ) xlpe screened 3 core cable 1299 25 50 mm2 1300 70 120 mm2 1301 150 185 mm2 1302 240 300 mm2 1303 in door termination kit for 22kv ( e ) xlpe screened 3 core cable 1304 25 50 mm2 1305 70 120 mm2 1306 150 185 mm2 1307 240 400 mm2 1308 out door termination kit for 22kv ( e ) xlpe screened 3 core cable 1309 25 50 mm2 1310 70 120 mm2 1311 150 185 mm2 1312 240 400 mm2 1313 straight through joint for 22 kv ( e ) xlpe screened 3 core cable 1314 25 50 mm2 1315 70 95 mm2 1316 120 150 mm2 1317 185 240 mm2 1318 300 400 mm2 1319 in door termination kit for 33kv ( e ) xlpe screened 3 core cable 1320 25 50 mm2 1321 70 95 mm2 1322 120 185 mm2 1323 240 400 mm2 1324 out door termination kit for 33 kv ( e ) xlpe screened 3 core cable 1325 25 50 mm2 1326 70 95 mm2 1327 120 185 mm2 1328 240 400 mm2 1329 straight through joint for 33 kv ( e ) xlpe screened 3 core cable 1330 35 70 mm2 1331 95 150 mm2 1332 185 300 mm2 1333 400 mm2...