Jharkhand Bijli Vitran Nigam Limited - Jharkhand

41037730 tender for supply of materials earth clamp for earthwire (50 x 6 mm) [galvanized] 11kv pole top bracket 50x8 mm flat [galvanized] 11 kv back clamp for top bracket [galvanized] 11 kv v cross arm (75x 40x 6 mm) [galvanized] 11 kv back clamp for v cross arm [galvanized] support clamp for 11 kv v cross arm [galvanized] 11 kv back clamp for line dp channel[galvanized] 11 kv d.p channel support clamp (50x6 mm) [galvanized] 11 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized] angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized] clamp (50 x 6 mm flat) for top channel [galvanized] clamp (50 x 6 mm) for ab switch base channel [galvanized] ms channel (100x50x6 mm) for 11 kv ab switch [galvanized] 11kv top channel (100x50x6) [galvanized] ms angle for l t distribution bus (35 x 35 x6 mm) [galvanized] transformer base channel (100x50x6 mm) [galvanized] ms channel (75x40x6 mm)for supporting h.g fuse & l.a [galvanized] transformer belting (50x50x6 mm) & belting support (40x40x6 mm) [galvanized] clamp (50 x 6 mm) for transformer base channel [galvanized] clamp (50 x 6 mm) for transformer belting [ [galvanized] clamp (50 x 6 mm) for lt bus & h.g fuse set [galvanized] 33kv v cross arm 33 kv pole top bracket 33 kv tapping channel b/c for v cross arm b/c for top bracket b/c for tapping channel support clamp for 33 kv v cross arm [galvanized] side angle stay clamp(400kg pole) 50x10 ...

Jharkhand State Electricity Board - Jharkhand

40449431 electric line materials under adphead for f.y. 2023 24 , 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 240 mm2 , 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 240 mm2 , 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 95 50 mm2 , 11 kv 3 core heat shrinkable straight through cable jointing / termination kit 95 150 mm2 , 415 v ac power distribution board , 30 v dc distribution board , 30 v 80 ah battery charging unit complete with battery and stand , adhesive insulation tape , 400 watt / 250 v hpsv lamp fitting complete for 33 / 11 kv pss yard lightining , aluminium binding wire , p.g clamp for 50 mm2 , earth clamp for earthwire ( 50x6 mm ) [ galvanized ] ( 1.8 kg ) , aluminium pipe 40 mm dia...

Jharkhand State Electricity Board - Jharkhand

39996881 tender for supply of electric line materials under adphead for f.y. 2022 23 lt ab cable accessory, 1.1mtr. stainless steel strap if207 ( 20x0.7 ) , buckle for strap , pre insulated mid span joint suitable 70mm2 phases , spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement , aluminium binding wire , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , p g clamp for 100 sq mm conductor , p g clamp for 80 sq.mm , male female contact of 11 kv ab switch 600 amp ( 1male+2female ) , m s nuts & bolts of different size...

Jharkhand State Electricity Board - Jharkhand

39893360 supply of electric line materials , electrical items : , gi earthing pipe 40 mm 3.1 mtrs. long , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , gi wire 6 swg , gi wire 8 swg...

Jharkhand State Electricity Board - Jharkhand

39846701 procurement of electric line materials under suppl. head 2022 23, adp head 2023 24 & o & mhead 2023 24 , electrical items : , gi earthing pipe 3.1 meter long & 40 mm dia including 10 kgs bentonite clay or powder. , earth clamp for earthwire (50 x 6 mm)[galvanized]...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

39630728 tender for supply of under mentioned operation and maintenance head materials gi earthing pipe 40 mm 3.1 mtrs. long earth clamp for earthwire (50 x 6 mm)[galvanized] gi wire 6 swg gi wire 8 swg ...

Jharkhand State Electricity Board - Jharkhand

38673490 supply of electric line materials under adp head supplementary budget fy 2022 23 : , 11kv top channel (100x50x6) 9.56 kg per meter [galvanized] , 33 kv v cross arm (100x 50x 6 mm) [galvanized] , 11 kv v cross arm (75x 40x 6 mm) [galvanized] , 33kv d p channel ( 100x50x6 mm) 1.3 meter long [ galvanized] , 11 kv d.p channel(75x 40x 6 mm) [galvanized] , 33 kv pole top bracket for 60kg rail pole [galvanized] , 11kv pole top bracket 50x8 mm flat [galvanized] , 33 kv cross bracing for dp channel , 11 kv d.p cross brancing , 11 kv tapping channel , ms channel (100x50x6 mm) for 11 kv ab switch [galvanized] , ms channel (75x40x6 mm)for supporting h.g fuse & l.a [galvanized] , transformer base channel (100x50x6 mm) [galvanized] , transformer belting (50x50x6 mm) & belting support (40x40x6 mm)[galvanized] , lt angle bracket (35x35x6 mm)[galvanized] , m s angle (65x65x6 mm) for guarding of 33 kv, 11 kv, l.t line , stay set complete (1900x16 mm) with stay wire 7/12 swg , stay set complete (1800x20 mm) with staywire 7/10 swg , earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) , earthing g.i.strip (65x6)mm2 , earth clamp for earthwire (50 x 6 mm) , stay clamp side/angle (50 x 10 mm) , 33 kv clamp for cross bracing , 11 kv clamp for cross bracing , support clamp for v cross arm , d p channel support clamp ( 50x6 mm) feet (1 pair = 1 set) for 60kg rail pole[galvanized] , clamp for ab switch base channel(50x6 mm) ( 1 set for 2 pair ) for 60kg rail pole[galvanized] , clamp (50 x 6 mm) for transformer base channel [galvanized] , clamp (50 x 6 mm) for transformer belting [ galvanized] , clamp (50 x 6 mm) for lt bus & h.g fuse set [galvanized] , u clamp (40 x 6 mm) , p g clamp 150 sq. , back clamp for top channel , back clamp for 60 kg rail pole , packing piece for rail pole , back clamp for 33 kv v crossarm & top bracket , 33 kv back clamp for line dp channel , 11kv back clamp for d.p channel , back clamp for 11 kv tapping channel , lt back clamp (50 x 6 mm) for lt angle[galvanized] , m s nuts & bolts of different size , g i wire no. 8 swg , g i wire no. 7/10, 7/12, 7/14, 7/16 , note:gst must be define/ mentioned otherwise price part not be considered....

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

38637109 tender for supply of following materials 11kv top channel (100x50x6) 9.56 kg per meter [galvanized] 33 kv v cross arm (100x 50x 6 mm) [galvanized] 11 kv v cross arm (75x 40x 6 mm) [galvanized] 33kv d p channel ( 100x50x6 mm) 1.3 meter long [ galvanized] 11 kv d.p channel (75x 40x 6 mm) [galvanized] 33 kv pole top bracket for 60kg rail pole [galvanized] 11kv pole top bracket 50x8 mm flat [galvanized] 33 kv cross bracing for dp channel 11 kv d.p cross brancing 11 kv tapping channel ms channel (100x50x6 mm) for 11 kv ab switch [galvanized] ms channel (75x40x6 mm)for supporting h.g fuse & l.a [galvanized] transformer base channel (100x50x6 mm) [galvanized] transformer belting (50x50x6 mm) & belting support (40x40x6 mm)[galvanized] lt angle bracket (35x35x6 mm)[galvanized] m s angle (65x65x6 mm) for guarding of 33 kv, 11 kv, l.t line stay set complete (1900x16 mm) with stay wire 7/12 swg stay set complete (1800x20 mm) with staywire 7/10 swg earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) earthing g.i.strip (65x6)mm2 earth clamp for earthwire (50 x 6 mm) stay clamp side/angle (50 x 10 mm) 33 kv clamp for cross bracing 11 kv clamp for cross bracing support clamp for v cross arm d p channel support clamp ( 50x6 mm) feet (1 pair = 1 set) for 60kg rail pole[galvanized] clamp for ab switch base channel(50x6 mm) ( 1 set for 2 pair ) for 60kg rail pole[galvanized] clamp (50 x 6 mm) for transformer base channel [galvanized] clamp (50 x 6 mm) for transformer belting [ galvanized] clamp (50 x 6 mm) for lt bus & h.g fuse set [galvanized] u clamp (40 x 6 mm) p g clamp 150 sq. back clamp for top channel back clamp for 60 kg rail pole packing piece for rail pole back clamp for 33 kv v crossarm & top bracket 33 kv back clamp for line dp channel 11kv back clamp for d.p channel back clamp for 11 kv tapping channel lt back clamp (50 x 6 mm) for lt angle[galvanized] m s nuts & bolts of different size g i wire no. 8 swg g i wire no. 7/10, 7/12, 7/14, 7/16 ...

Damodar Valley Corporation - Jharkhand

38375601 rehabilitation of damaged tower at location no.12 of dc line mhs kumardhubi or phs (l 16 and 17) by an adjacent tower including foundation erection of tower and dismantling and re stringing of conductor earthwire accessories rehabilitation of damaged tower at location no.12 of dc line mhs kumardhubi or phs (l 16 and 17) by an adjacent tower including foundation erection of tower and dismantling and re stringing of conductor, earthwire accessories => limited...

Jharkhand State Electricity Board - Jharkhand

38205983 procurement of electrical 33 kv line fabricated galvanized items under supplementary budget adp head 2022 23 supply of materials under adp head 2022 23 , electrical items : , gi base plate for 33kv(500x500x10mm) , 33 kv v cross arm (100x 50x 6 mm) [galvanized] , back clamp ( 50x6 mm) for v cross arm for 60kg rail pole[galvanized] , 33 kv pole top bracket for 60kg rail pole [galvanized] , 33 kv back clamp for top bracket [galvanized] , support clamp for v cross arm & top bracket for 60kg rail pole[galvanized] , back clamp (50x6 mm)jointing/ packing piece for 60kg rail pole [galvanized] , 33 kv angle/side stay clamp (50 x 6 mm) [galvanized] , 33 kv back clamp for line dp channel [galvanized] , 33 kv d.p channel support clamp (50x6 mm) [galvanized] , 33 kv d.p channel(100x50x6 mm) [galvanized] , 33 kv dp cross bracing [galvanized] , support clamp for cross bracing for 60kg rail pole [galvanized] , back clamp for dp cross bracing for 60kg rail pole [galvanized] , earth clamp for earthwire (50 x 6 mm) [galvanized] , angle for guarding(65x65x6mm)[galvanized] , back clamp for angle for guarding for 60kg rail pole[galvanized]...

Jharkhand State Electricity Board - Jharkhand

37102511 tender for electric line materials under adphead for f.y. 2022 23 electrical line materials , aluminium binding wire , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , p g clamp for 100 sq mm conductor , p g clamp for 80 sq.mm , male female contact of 11 kv ab switch 600 amp , gi wire no. 8 , m s nuts & bolts of different size...

Jharkhand State Electricity Board - Jharkhand

35247016 supply of electrical line materials , earthing g.i.strip for ( 65x6 ) , t / c fuse wire 12 swg , t / c fuse wire 14 swg , t / c fuse wire 16 swg , t / c fuse wire 18 swg , gi wire 6 swg , gi wire 8 swg , gi wire no. 10 for earthing , earthing ( chemical ) with gi earthing pipe 20 mm 2.5 mtrs. long , gi earthing pipe 3.1 meter long ( 40 mm dia ) , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , stay set complete ( 1900x20 mm ) with staywire 7 / 10 swg 8 kgs & guy insulator ) , stay set complete ( 1800x20 mm ) with staywire 7 / 10 swg 8 kgs & guy insulator ) , stay set complete for dss with wire , lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg...

Jharkhand State Electricity Board - Jharkhand

33860159 supply of electrical line materials under esa giridih , electrical items : , stay set complete for dss with wire , lt stay set complete ( 1700 x 16 mm ) with staywire 7 / 12 swg , ms nuts & bolts 3 ( f.th. ) ( galvanized ) , ms nuts & bolts 4 ( f.th. ) ( galvanized ) , ms nuts & bolts 8 ( f.th. ) ( galvanized ) , ms nuts & bolts 10 ( f.th. ) ( galvanized ) , pg clamp for 100 sq. mm conductor , pg clamp for 80 sq. mm , angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] , earth clamp for earthwire ( 50x6 mm ) [ galvanized ] , clamp ( 50x6 mm ) for transformer base channel [ galvanized ] [ 1.080 kg. per no. ] , clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] [ 1.220 kg. per no. ] , clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] [ 1.120 kg. per no. ] , clamp ( 50 x 6 mm ) for ab switch base channel [ galvanized ] [ 0.875 kg. per no. ] , clamp ( 50 x 6 mm flat ) for transformer top channel [ galvanized ] , ms flat ( 40 x 6 mm & 6 mtrs. long ) [ galvanized ] ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

33840224 supply of electrical line materials , 1 stay set complete for dss with wire 2 lt stay set complete (1700 x 16 mm) with staywire 7/12 swg 3 ms nuts & bolts 3 (f.th.) (galvanized) 4 ms nuts & bolts 4 (f.th.) (galvanized) 5 ms nuts & bolts 8 (f.th.) (galvanized) 6 ms nuts & bolts 10 (f.th.) (galvanized) 7 pg clamp for 100 sq. mm conductor 8 pg clamp for 80 sq. mm 9 angle/side stay clamp (50x6 mm) for 8 mtr 200kg psc pole [galvanized] 10 earth clamp for earthwire (50x6 mm) [galvanized] 11 clamp (50x6 mm) for transformer base channel [galvanized] [1.080 kg. per no.] 12 clamp (50 x 6 mm) for transformer belting [galvanized] [1.220 kg. per no.] 13 clamp (50 x 6 mm) for lt bus & h.g fuse set [galvanized] [1.120 kg. per no.] 14 clamp (50 x 6 mm) for ab switch base channel [galvanized] [0.875 kg. per no.] 15 clamp (50 x 6 mm flat) for transformer top channel [galvanized] 16 ms flat (40 x 6 mm & 6 mtrs. long) [galvanized]...

Department Of Heavy Industry - Jharkhand

32443625 bids are invited for 400kv, 50ka for 1s, 3150a, cb connector suitable for al tube 4 inch ips, expansion type , 400kv, 50ka for 1s, 3150a, isolator hcb connector suitable for al tube 4 inch ips, rigid type , 400kv, 50ka for 1s, 2000a, isolator hcb connector suitable for twin moose , 400kv, 50ka for 1s, 3150a, ct connector suitable for al tube 4 inch ips, rigid type , 400kv, 50ka for 1s, 3150a, ct connector suitable for al tube 4 inch ips, expansion type , 400kv, 50ka for 1s, cvt connector suitable for twin moose , 400kv, 50ka for 1s, la connector suitable for twin moose , 400kv, 50ka for 1s, 3150a, bpi connector suitable for al tube 4 inch ips, sliding through type , 400kv, 50ka for 1s, bpi connector suitable for al tube 4 inch ips, rigid through type , 400kv, 50ka for 1s, bpi connector suitable for twin moose horizontal approach , 400kv, 50ka for 1s, 3150a, bpi connector suitable for al tube 4 inch ips, rigid and expansion type with tube break , 400kv, 50ka for 1s, 2000a, bushing connector suitable for twin moose , 400kv corona bell suitable for 4 inch ips al tube , 400kv, 50ka for 1s, 1000a, tee connector suitable for single moose to single moose , 400kv, 50ka for 1s, 1000a, tee connector suitable for twin moose to single moose , 400kv 50ka for 1s 2000a tee connector suitable for al tube 4 inch ips to twin conductor as per ts , 400kv, flexible spacer suitable for twin moose , 400kv, rigid spacer suitable for twin moose , 400kv, welding sleeve suitable for 4 inch ips al tube , 220kv, 40ka for 1s, 1600a, cb connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for twin moose , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, rigid type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, expansion rigid type with tube break , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, rigid rigid type with tube break , 220kv, 40ka for 1s, 2000a, ct connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 2000a, ct connector suitable for twin moose , 220kv, 40ka for 1s, cvt connector suitable for single moose , 220kv, 40ka for 1s, la connector suitable for twin moose , 220kv, 40ka for 1s, bpi connector suitable for al tube 4 inch ips, sliding through type , 220kv, 40ka for 1s, 1600a, bpi connector suitable for al tube 4 inch ips, rigid and expansion type with tube break , 220kv, 40ka for 1s, 1600a, bpi 90 degree connector suitable for al tube 4.5 inch ips, expansion expansion type with tube break , 220kv, 40ka for 1s, 1600a, bushing connector suitable for twin moose , 220kv corona bell suitable for 4 inch ips al tube , 220kv, 40ka for 1s, 1000a, tee connector suitable for single moose to single moose , 220kv, 40ka for 1s, 1000a, tee connector suitable for twin moose to single moose , 220kv, 40ka for 1s, 2000a, tee connector suitable for al tube 4 inch ips to twin conductor as per ts , 220kv, 40ka for 1s, flexible spacer suitable for twin moose , 220kv, 40ka for 1s, rigid spacer suitable for twin moose , 220kv, welding sleeve suitable for 4 inch ips al tube , strain tension clamps bolted type for earthwire with d shackle assembly , clamps and connectors pg clamp for shield wires of dia 10.98mm , cleat type clamps for earthing down conductor 10.98mm dia , cleat type clamps for 75 x 12mm g.s. flat for equipment structure , pad type clamp for connecting 10.98mm dia. g.i. wire on one side and 75x12mm gs strips on other side auto extension if any seller submits price in last 15 minutes, the rawill be auto extended by 15 minutes. ( for anunlimited time ) total quantity : 1268...

Jharkhand State Electricity Board - Jharkhand

31955758 rate of materials supply of materials ( i ) rail pole 60 kgs 13 meter ( ii ) rail pole 52 kgs 13 meter ( iii ) rs joist pole 9.3 meter ( 175x85mm ) 19.6 kgs per mtr ( iv ) rs joist pole 9 meter ( 116x100mm ) 23 kgs per mtr ( v ) 125x70x5 rs gi joist 8mtr ( 13.3kg / mtr ) ( vi ) wpb 160x160, 30.4kg / m weather resistant h beam, 11m ( vii ) wpb 160x160, 30.4kg / m weather resistant h beam, 13m ( viii ) psc pole 400 kg w.l ( 9 mtr. ) ( ix ) psc pole 200 kg w.l ( 8 mtr. ) ( x ) steel tubular pole ( sp 32 ) of 9 meter ( xi ) steel tubular pole ( sp 55 ) of 11 meter ( xii ) steel tubular pole ( sp 72 ) of 13meter acsr conductors ( i ) acsr panther conductor ( 232 sq. mm ) ( ii ) acsr wolf conductor ( 150 sq. mm ) ( iii ) acsr dog conductor ( 100 sq. mm ) ( iv ) acsr racoon conductor ( 80 sq. mm ) ( v ) acsr rabbit conductor ( 55 mm2 ) ( vi ) acsr weasel conductor ( 34 sq. mm ) insulators & h / w fittings ( i ) 33 kv pin insulator 10 kn with pin ( porcelain type ) ( ii ) 33 kv polymer pin insulators 10 kn with gi pin and nut & washer ( iii ) 33 kv disc insulator ( polymer type ) 90 kn with h / w fitting and nut & washer ( iv ) 33 kv disc. insulator ( porcelain type ) 70 kn with h / w fitting ( v ) 33 kv disc insulator ( polymer type ) 70 kn with h / w fitting ( vi ) suspension hardware suitable for panther conductor ( vii ) tension hardware suitable for panther conductor ( viii ) 11 kv pin insulator 10 kn, od 40 mm dia with pin ( polymer type ) and nut & washer ( ix ) 11 kv pin insulator 5kn with pin ( porcelain type ) ( x ) 11 kv pin insulator 5 kn with pin ( polymer type ) and nut & washer ( xi ) 11 kv disc insulator ( polymer type ) 70 kn with h / w ( xii ) 11 kv disc insulator ( porcelain type ) 45 kn with h / w ( xiii ) 11 kv disc insulator ( polymer type ) 45 kn with h / w ( xiv ) lt pin insulator with pin ( porcelain type ) ( xv ) lt pin insulator ( porcelain type ) ( xvi ) lt shackle insulator ( porcelain type ) ( xvii ) lt shackle strip with bolts and nut ( xviii ) 33 kv post insulator 10 kn ( polymer ) ( xix ) 11 kv post insulator 5 kn ( polymer ) ( xx ) 33 kv stay insulator ( xxi ) 11 kv stay insulator ( xxii ) lt stay insulator ( xxiii ) mid span compression joints suitable for acsr panther conductor ( xxiv ) repairing sleeve suitable for acsr panther conductor isolator ( i ) 33 kv isolator 800 amp , 3 phase, with earth switch ( ii ) 33 kv isolator 800 amp , 3 phase, with out earth switch ( iii ) 33 kv isolator 630 amp, 3 phase, without earth switch ( iv ) 33 kv isolator 630 amp, 3 phase, with earth switch ( v ) 33 kv isolator 400 amp, 3 phase, with earth switch ( vi ) 11 kv isolator 630 amp, 3 phase, with earth switch ( vii ) 11 kv isolator 630 amp, 3 phase, without earth switch ( viii ) 11 kv isolator 400 amp, 3 phase, without earth switch ( ix ) 11 kv isolator 400 amp, 3 phase, with earth switch ( x ) 11 kv isolator 200 amp single phase ab switch ( i ) 33 kv 3 pin type, 3 phase, ab switch 800 amp ( porcelain type ) ( ii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( iii ) 33 kv 3 pin type, 3 phase, ab switch 630 amp ( polymer type ) ( iv ) 11 kv 3 pin type, 3 phase, ab switch 630 amp ( porcelain type ) ( v ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( polymer type ) ( vi ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( porcelain type ) ( vii ) 11kv ab switch 200 amps ( single break ) lightening arrestor ( i ) lightening arrestor ( 9kv 5ka ) line type ( ii ) 11 kv lightening arrester ( 9 kv, 10 ka class ii, station type ) ( 1set=3nos ) ( iii ) 33 kv lightening arrester ( 30kv, 10ka class ii, station type ) ( 1set=3nos ) earthing ( i ) 25mm dia ms rod 3 m long for earth mat ( ii ) spike earthing made of 20mm gi solid rod ( iii ) g.i earthing strip size 75x8 mm ( iv ) g.i earthing strip size 35x3 mm ( v ) g.i earthing strip size 35x4 mm ( vi ) g.i earthing strip size 40x4 mm ( vii ) g.i earthing strip size 40x5 mm ( viii ) insulated gi / alum.flexible wire 16 sq.mm ( ix ) ace chemrod ( artificial concept of earthing by chemical rod ) : ace chemrod earthing electrode ( consisting mild steel galvanised pipe of size 2500 mm in length x 48 mm outer dia. x 2 mm thick, ms rod of size 2575 mm x 16 mm be welded with bottom. the epoxy insulator of not less than 100 mm length is to be fixed on top of mild steel galvanised pipe. a highly conductive substance is to be filled in residual gap between pipe and rod ) with highly conductive substances not less than 25 kg for soil treatment ( x ) earthing complete conventional type having intermittent layer of charcoal and salt stay set ( i ) gi stay set complete for d / s / s ( 1900x 16mm ) with staywire 7 / 12 swg and guy insulator ( ii ) gi stay set complete for d / s / s ( 1900x 20mm ) with staywire 7 / 10 swg and guy insulator ( iii ) stay set complete ( 1800x20mm ) with stay wire 7 / 10 swg & guy insulator ( galvanised ) ( iv ) 11 kv stay set complete ( 1800x16 mm ) with stay wire 7 / 10 swg and guy insulator ( v ) lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg ( vi ) gi stay wire no. 7 / 8, 7 / 10, 7 / 12, 7 / 14, 7 / 16 p.g.clamps ( i ) p g clamp for 232 / 150 sq mm conductor ( ii ) p g clamp for 80 / 100mm2 ( iii ) p g clamps for 34 / 55mm2 ( iv ) bimettalic clamps for distribution transformers ht side ( 25 to 200 kva ) ( v ) bimettalic clamps for distribution transformers ht side above ( 200 kva ) ( vi ) bimettalic clamps for distribution transformers lt side ( 25 to 200 kva ) ( vii ) bimettalic clamps for distribution transformers lt side above ( 200 kva ) ( viii ) bimettalic clamps for power transformer 5 mva ( ix ) bimettalic clamps for power transformer 10 mva ( x ) bimettalic clamps for vcbs for 33kv and 11 kv ( xi ) bimettalic clamps for ct pt unit ( xii ) p g clamp 3 bolt for abt meters structures, gantry columns and base plates ( i ) structure for 33kv lightening arrestor [ non galvanized ] ( ii ) structure for 33kv lightening arrestor [ galvanized ] ( iii ) structure for 33 kv isolator ( galvanised ) ( iv ) structure for 11 kv isolator ( galvanised ) ( v ) structure for 33 kv isolator [ galvanized ] ( vi ) structure for 11 kv isolator [ galvanized ] ( vii ) structure for 33 kv pt ( non galvanised ) ( viii ) structure for 33 kv pt [ galvanized ] ( ix ) structure for 11 kv pt ( non galvanised ) ( x ) structure for 11 kv pt [ galvanized ] ( xi ) structure for post insulator for 11kv ( galvanised ) ( xii ) structure for post insulator for 33 kv [ galvanized ] ( xiii ) structure for 33 kv hg fuse set ( non galvanised ) ( xiv ) structure for 33 kv hg fuse set [ galvanized ] ( xv ) a swing bus structure ( xvi ) gantry column, girder structures for 33 / 11 kv pss for single transformer [ galvanized ] ( xvii ) a structures for top mounted ab switch on 33 kv bus [ galvanized ] ( xviii ) a structures for top mounted ab switch on 11 kv bus [ galvanized ] ( xix ) a structures for 11 kv take off with top mounted ab switch and provision of lightening arrester [ galvanized ] ( xx ) gi base plate for 33kv ( 500x500x10 mm ) avg weight 19.6kg / plate ( xxi ) stone base plate for 11 kv, dss, lt current and potential transformers ( i ) 33 kv ct outdoor oil immersed type, 3 core, 200 100 / 5 5 1 amp, class 0.5 for differential protection ( ii ) 33 kv ct outdoor oil immersed type, 3 core, 300 150 / 5 5 1 amp, class 0.5 for differential protection ( iii ) 33 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( iv ) 33 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( v ) 33 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vi ) 33 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vii ) 11 kv ct outdoor oil immersed type, 3 core, 600 300 / 5 5 1amp, class 0.5 for differential protection ( viii ) 11 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( ix ) 11 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( x ) 11 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xi ) 11 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xii ) 33 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) ( xiii ) 11 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) power transformer ( i ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( off load tap changer ) ( ii ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( on load tap changer ) ( iii ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( off load tap changer ) ( ivi ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( on load tap changer ) distribution transformer ( i ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 1 ( ii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 2 ( iii ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 3 ( iv ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 4 ( v ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 5 ( vi ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 1 ( vii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 2 ( viii ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 3 ( ix ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 4 ( x ) 11 / 0.433 kv distribution transformer 400 kva, copper wound, crgo m4 core onan; bis level 5 ( xi ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 1 ( xii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 2 ( xiii ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 3 ( xiv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 4 ( xv ) 11 / 0.433 kv distribution transformer 315 kva, copper wound, crgo m4 core onan; bis level 5 ( xvi ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 1 ( xvii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 2 ( xviii ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 3 ( xix ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 4 ( xx ) 11 / 0.433 kv distribution transformer 250 kva, aluminium wound, crgo m4 core onan; bis level 5 ( xxi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 1 ( xxii ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 2 ( xxiv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 3 ( xxv ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 4 ( xxvi ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; bis level 5 ( xxvii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxviii ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxix ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxx ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxi ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxiii ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating ; bis level 2 ( xxxiv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xxxv ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xxxvi ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xxxvii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xxxviii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xxxix ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xl ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xli ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; bis level 5 ( xlii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 1 ( xliii ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 2 ( xliv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 3 ( xlv ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted; bis level 4 ( xlvi ) 11 / 0.433 kv distribution transformer 16 kva, aluminium winding, stack type crgo core fitted ; bis level 5 distribution box ( i ) lt distribution box suitable for 500 kva transformer ( 800 a, isolator & 12 sp mccb of 160 a ) ( ii ) lt distribution box suitable for 400 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 315 kva transformer ( 600 a, isolator & 9 sp mccb of 160 a ) ( iii ) lt distribution box suitable for 200 kva transformer ( 400 a, isolator & 9 sp mccb of 160 a ) ( v ) lt distribution box suitable for 100 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( v ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & four pole mccb & 6 sp mccb of 120 a ) ( vii ) ltdb for 100kva & 63kva, isolator 250a, incoming mccb 4p, 200a, 36ka, outgoing mccb 3p 100a, 36ka ( viii ) ltdb for 25kva, isolator 63a, incoming mccb 4p, 63a, 20ka, outgoing mccb 3p 32a, 20ka ( ix ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & 6 tp mccb of 100 a ) ( x ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 6 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xi ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 9 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 3 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 5 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xiv ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 8 out ( dist. box for fixing on pole suitable for ab xlpe cable ) ( xv ) spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement vcb, c&r panel ( i ) 33 kv vcb, 1250 amp., outdoor type, 26.3 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 1200 600 300 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, with metering system in panel with numeric relay announciator ( ii ) 33 kv vcb, 1250 amp., outdoor type, 16 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 600 300 / 1 1a or 400 200 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( iii ) 11 kv vcb, outdoor type, 1250 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 1200 600 300 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va with metering system in panel ( iv ) 11 kv vcb, outdoor type, 800 a, for incoming, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( v ) 11 kv vcb, outdoor type, 630 a, 25 ka for 3 sec. rupturing capacity wth c&r panel. ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 11 kv / 110v, accuracy class 0.5, 30 va ( vi ) 11 kv vcb, outdoor type, 400 a, for outgoing, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated with ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( vii ) indoor type control and relay panel for 33kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. ( viii ) indoor type control and relay panel for 33kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( ix ) indoor type control and relay panel for 11kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete. ( x ) indoor type control and relay panel for 11kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. distribution board ( i ) 415v ac power distribution board ( ii ) 30v dc distribution board pipe connector ( i ) aluminium pipe connector ( ii ) connector pipe to panther ( iii ) connector panther to panther ( iv ) connector panther to ab switch ( v ) connector pipe to pipe ( vi ) connector pipe to dog ( vii ) connector pipe to ab switch ( viii ) connector dog to ab switch copper control cable ( i ) 2.5 mm2 copper 2 core control cable ( armoured ) ( ii ) 2.5 mm2 copper 2 core control cable ( unarmoured ) ( iii ) 2.5 mm2 copper 4 core control cable ( armoured ) ( iv ) 2.5 mm2 copper 4 core control cable ( unarmoured ) ( v ) 2.5 mm2 copper 6 core control cable ( armoured ) ( vi ) 2.5 mm² copper 6 core un armourd cable ( vii ) 7 core x 2.5 sq.mm. armoured control cable ( viii ) 2.5 mm2 copper 8 core control cable ( unarmoured ) ( ix ) 2.5 mm2 copper 10 core control cable ( armoured ) ( x ) 2.5 mm2 copper 10 core control cable ( unarmoured ) ( xi ) 2.5 mm2 copper 12 core control cable ( armoured ) ( xii ) 2.5 mm2 copper 12 core control cable ( unarmoured ) ( xiii ) 19 core x 2.5 sq.mm.armoured control cable capacitor bank ( i ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 3600 kvar ( ii ) 1815 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 kvar+726 kvar+726 kvar 12.1 kv bank shall be complete with capacitor units of 121 kvar at 6.98 kv including allied materials such as suitable size of aluminium busbars, pin / pos ( iii ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 1200 kvar ( iv ) 1089 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 metering equipment ( i ) 33 kv metering cubicle with pt & ct , 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( ii ) 33 kv outdoor type oil immersed ct pt combined metering unit 0.5s accuracy class for ct and 0.5s accuracy class for pt of different capacity ( iii ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( modular rack mounted ) of different capacity ( iv ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( projection type ) of different capacity ( v ) 33 kv / 110 v, three phase four wire, ( 0.2s accuracy class for ct and 0.2 accuracy class for pt ) , ratio 1600 / 1a or 1200 / 1a ct pt combined metering unit for feeder ( vi ) metering panel, data concentrator unit ( dcu ) with modem ( vii ) structure for 33 kv metering unit ( viii ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.2s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( ix ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.5s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( x ) trivector energy meter of 800 / 5 amp ( xi ) trivector energy meter of 400 / 5 amp ( xii ) 11 kv, outdoor type oil immersed ct pt combined metering unit, 3 phase 4 wire ( 11kv / 110v ) [ 12 kv pt 50va burden 0.5s accuracy class; ct 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 15 va, 0.5 accuracy class ] ( xiii ) 11 kv metering cubicle with pt ratio 11kv / √3 / 110v and ct ratio 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 0.5 accuracy class for both ( xiv ) ltct electronic meter ( 200 / 150 / 100 / 5 ) 3 phase 4 wire with meter box, class 0.5s accuracy ( xv ) ac 3 phase, 4 wire, 40 200amp lt electronic trivector accuracy class 1.0 dlms compliant category a meter with inbuilt cts and inbuilt 4g with fall back option gprs modem ( xvi ) structure for d.t meter ( xvii ) ac 3 phase dtr meter complete set above 100kva 400 / 5a ( xviii ) lt electronic trivector meter 40 200 amp. ( xix ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 200 / 5a ( xx ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 5a ( xxi ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 5a ( xxii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 1a ( xxiii ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 1a ( xxiv ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 1a ( xxv ) 11kv / 110, 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 5a ( xxvi ) 11 kv / 110 v 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 200 / 5 a ( xxvii ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 600 / 1a ( xxviii ) 11 kv / 110, 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 600 / 5 a ( xxix ) dlms compliant, single phase 2 wire 5 30 amp. 1.0 accuracy, class ac statics single phase meter with meter box ( xxx ) lt static energy meter, 3 phase 4 wire, direct connected, 100 amp. with meter box, class 1.0 accuracy ( xxxi ) three phase 4 wire ac static whole current meter, electronic energy meter with box ( 10 60 ) amp ( xxxii ) single phase electronic meter, two wire, 5 30 amp. class 1.0 accuracy with box ( xxxiii ) single phase rf meter with box as per is 13779 standards, dlms compliant ( xxxiv ) three phase rf meter with box as per is 13779 standards, dlms compliant ( xxxv ) single phase rs 232 / 485 prepaid energy meter ( xxxvi ) three phase rs 232 / 485 prepaid energy meter ( xxxvii ) single phase rf prepaid energy meter ( xxxviii ) three phase rf prepaid energy meter ( xxxix ) single phase gprs / gsm prepaid energy meter ( xl ) three phase gprs / gsm prepaid energy meter ( xli ) pvc cable gland sizes 20 mm, ( xlii ) pvc cable gland sizes 25 mm, ( xliii ) pvc cable gland sizes 32 mm ( xliv ) pvc cable gland sizes 40 mm ( xlv ) pvc cable gland sizes 50 mm ( xlvi ) pvc cable gland sizes 63 mm ( xlvii ) pvc cable gland sizes 75 mm ( xlviii ) single phase whole current smart meter ( 5 30 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( xlix ) three phase whole current smart meter ( 10 50 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( l ) three phase whole current smart meter ( 20 100 amp ) with rf communication module ( excl. nic card ) incl. polycarbonate meter box ( li ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 100 / 5 amp ) ( lii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio 200 / 5 amp ) ( liii ) lt three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. smc double chambered meter box with embeded ct ( ct ratio / 5 amp ) ( liv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for feeder ( ct raio / 5amp ) ( lv ) ht three phase ct operated smart tri vector meter with rf communication module ( excl. nic card ) for consumer incl. meter box ( ct raio / 5amp ) ( lvi ) field routers / collectors / dcu along with installation clamp and accessories complete ( lvii ) network interface card ( nic ) for smart meter ( lviii ) centralized management console with single 24 led monitor ( lix ) work station consoles with dual 24 led monitor along with operating system, antivirus & license ( lx ) network laserjet ( b / w ) photocopy, scanning and printing ( lxi ) a4 size inkjet / bubble jet printer ( lxii ) a3 size inkjet color printer / all in one color laserjet printer ( lxii ) l.t. ct ratio 50 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 100 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 200 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 300 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 400 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 500 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 600 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( lxii ) l.t. ct ratio 800 / 5a, 5va, 0.5 accuracy for metering, epoxy casted gi service pipe ( i ) gi service pipe 25 mm diameter 3 mtr length ( ii ) gi service pipe 40 mm diameter 3 mtr length ( iii ) gi service pipe 60mm diameter 3 mtr length ( iv ) g.i. pipe 3 dia ring main units ( i ) 11 kv 3 way rmu, 2od + 1vl, one incomer + one breaker + one outgoing ( ii ) 11 kv 4 way rmu, 2od + 2vl, ( one incomer + two breakers + one outgoing ( iii ) 11 kv 5 way rmu, 2od + 3vl, ( one incomer + three breakers + one outgoing ) ( iv ) 11 kv 6 way rmu, 2od + 4vl, ( one incomer + four breakers + one outgoing xlpe insulated cables ( i ) 33 kv ht xlpe cable single core 630mm2 ( armoured ) ( ii ) 1c x 400mm2 cable ( 33 kv power cable ) ( iii ) 33 kv ht xlpe cable 3 core 400 sq mm ( armoured ) ( iv ) 33 kv ht xlpe cable 3 core 300mm2 ( armoured ) ( v ) 33 kv ht xlpe cable 3 core 240mm2 ( armoured ) ( vi ) 33 kv ht xlpe cable 3 core 185mm2 ( armoured ) ( vii ) 33 kv ht xlpe cable 3 core 150mm2 ( armoured ) ( viii ) 33 kv ht xlpe cable 3 core 120mm2 ( armoured ) ( ix ) 33 kv ht xlpe cable 3 core 95mm2 ( armoured ) ( x ) 33 kv ht xlpe cable 3 core 70mm2 ( armoured ) ( xi ) 33 kv ht xlpe cable 3 core 50mm2 ( armoured ) ( xii ) 11 kv 3 core x 35 sq. mm cable ( armoured ) ( xiii ) 11 kv xlpe cable single core 630mm2 ( armoured ) ( xiv ) 3core x 630sq mm ( 11 kv power cable ) ( xv ) 11 kv xlpe cable 3 core 400mm2 ( armoured ) ( xvi ) 11 kv xlpe cable 3 core 300mm2 ( armoured ) ( xvii ) 11 kv xlpe cable 3 core 240 mm2 ( armoured ) ( xviii ) 11 kv xlpe cable 3 core 185mm2 ( armoured ) ( xix ) 11 kv xlpe cable 3 core 150mm2 ( armoured ) ( xx ) 11 kv xlpe cable 3 core 120mm2 ( armoured ) ( xxi ) 11 kv xlpe cable 3 core 95mm2 ( armoured ) ( xxii ) 11 kv xlpe cable 3 core 70mm2 ( armoured ) ( xxiii ) 11 kv xlpe cable 3 core 50mm2 ( armoured ) ( xxiv ) 11 kv xlpe cable 3 core 25mm2 ( armoured ) ( xxv ) power cable for dt meter 120 sq.mm unarmoured ( xxvi ) power cable for dt meter 240 sq.mm unarmoured ( xxvii ) lt xlpe cable 4 core 16 mm2 ( armoured ) ( xxviii ) lt xlpe cable 4 core 16mm2 ( unarmoured ) ( xxix ) lt xlpe cable 4 core 25mm2 ( armoured ) ( xxx ) lt xlpe cable 3.5 core 300mm2 ( armoured ) ( xxxi ) lt xlpe cable 3.5 core 185mm2 ( armoured ) ( xxxii ) lt xlpe cable 3.5 core 120mm2 ( armoured ) ( xxxiii ) lt xlpe cable 3.5 core 95 mm2 ( armoured ) ( xxxiv ) lt xlpe cable 3.5 core 50mm2 ( armoured ) ( xxxv ) lt xlpe cable 3.5 core 25mm2 ( armoured ) ( xxxvi ) lt xlpe cable 2 core 16 mm2 ( armoured ) ( xxxvii ) lt xlpe cable 2 core 10mm2 ( armoured ) ( xxxviii ) lt xlpe cable 2 core 6mm2 ( armoured ) ( xxxix ) lt xlpe cable 1cx120 sqmm ( armoured ) ( xl ) lt xlpe single core cable 95 mm2 ( armoured ) ( xli ) lt xlpe single core cable 50 mm2 ( armoured ) ( xlii ) lt xlpe single core cable 25 mm2 ( armoured ) ( xliii ) lt xlpe cable 3.5 core 35 sq. mm. ( armoured ) ( xliv ) lt xlpe cable 3.5 core 70 sq. mm. ( armoured ) ( xlv ) lt xlpe single core unarmoured 1 x 400 sqmm pvc insulated cables ( i ) 3.5 core 300 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ii ) 3.5 core 240 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iii ) 3.5 core 185 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iv ) 3.5 core 150 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( v ) 3.5 core 70 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vi ) 3.5 core 35 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vii ) 2 core 16 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( viii ) 1 core 120 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ix ) lt pvc cable 3.5 core 95 mm2 ( armoured ) ( x ) lt pvc cable 3.5 core 10 mm2 ( armoured ) ( xi ) lt pvc cable 3.5 core 6 mm2 ( armoured ) ( xii ) lt pvc cable 2 core 16 mm2 ( armoured ) ( xiii ) lt pvc cable 2 core 10 mm2 ( armoured ) ( xiv ) lt pvc cable 2 core 6 mm2 ( armoured ) ( xv ) lt pvc cable 2 core 4 mm2 ( armoured ) ( xvi ) lt pvc cable 1 core 16 mm2 ( armoured ) ( xvii ) lt pvc cable 1 core 50 mm2 ( armoured ) ( xviii ) lt pvc cable 1 core 70 mm2 ( armoured ) ( xix ) lt pvc cable 1 core 150 mm2 ( armoured ) ( xx ) lt pvc cable 1 core 300 mm2 ( armoured ) ( xxi ) pvc single phase service cable 3.5 core 25 mm2 ( amoured ) ( xxii ) 2.5 sq mm twin core pvc service cable ( armoured ) ( xxiii ) 4 sq mm twin core pvc service cable ( unarmoured ) ( xxiv ) pvc single phase service cable 2 core 2.5 mm2 ( unamoured ) ( xxv ) pvc single phase service cable 2 core 6 mm2 ( unarmoured ) ( xxvi ) pvc three phase service cable 4 core 6 mm2 ( armoured ) ( xxvii ) pvc three phase service cable 4 core 8 mm2 ( armoured ) ( xxviii ) pvc three phase service cable 4 core 10 mm2 ( armoured ) ( xxix ) pvc three phase service cable 4 core 16 mm2 ( armoured ) ( xxx ) pvc three phase service cable 4 core 25 mm2 ( armoured ) ( xxxi ) pvc three phase service cable 4 core 10 mm2 ( unarmoured ) aerial bunched cables ( i ) 11 kv xlpe ht ab cable 3cx185mm2+240mm2 bare messenger ( ii ) 11 kv xlpe ht ab cable 3cx185mm2+150mm2 bare messenger ( iii ) 11 kv xlpe ht ab cable 3cx150mm2+120mm2 bare messenger ( iv ) 11kv xlpe ht ab cable 3cx120 mm2 + 95mm2 bare messenger ( v ) 11 kv xlpe ht ab cable 3cx95mm2+80mm2 bare messenger ( vi ) 11 kv xlpe ht ab cable 3cx70mm2+70mm2 bare messenger ( vii ) 11 kv xlpe ht ab cable 3cx50mm2+70mm2 bare messenger ( viii ) 11 kv xlpe ht ab cable 3cx35mm2+70mm2 bare messenger ( ix ) 11 kv xlpe ht ab cable 3cx35mm2+35mm2 bare messenger ( x ) lt xlpe ab cable 3cx120+1cx70+1cx16 mm2 ( xi ) lt xlpe ab cable 3cx95 sqmm + 1x70 sqmm+1x70 sq mm ( xii ) lt xlpe ab cable 3cx95+1cx70+1cx16 mm2 ( xiii ) lt xlpe ab cable 3x70+1x50+1x16 ( street light ) mm2 ( xiv ) lt xlpe ab cable 3cx50 sqmm + 1x35 sqmm+1x16 sq mm ( xv ) lt xlpe ab cable 3x50+1x25+1x35 mm2 ( xvi ) lt xlpe ab cables 1x16 ( ph ) + 1x25 ( bare condustor + 1x16 ( insulated street lighting ) mm2 ( xvii ) lt xlpe ab cable 3cx120+70mm2 ( xviii ) lt xlpe ab cable 3cx95+70mm2 ( xix ) lt xlpe ab cable 3cx50+35mm2 ( xx ) lt xlpe ab cable 3cx35+25mm2 ( xxi ) lt xlpe ab cable 3cx25+25mm2 ( xxii ) lt xlpe ab cable 3cx16+25mm2 ( xxiii ) lt xlpe ab cable 1cx16+25mm2 single phase ab cable accessories ( i ) 11 kv ab cable straight thru joint kit suitable for 35 70 sqmm ( ii ) 11 kv ab cable straight thru joint kit suitable for 95 120 sqmm ( iii ) 11 kv abc termination kit 35 70 sqmm ( iv ) 11 kv abc termination kit 95 120 sqmm ( v ) lt pre insulated mid span joint suitable 25 mm2 phases ( vi ) lt pre insulated mid span joint suitable 35 mm2 phases ( vii ) lt pre insulated mid span joint suitable 50 mm2 phases ( viii ) lt pre insulated mid span joint suitable 70 mm2 phases ( ix ) lt pre insulated mid span joint suitable 95 mm2 phases ( x ) lt pre insulated mid span joint suitable 120 mm2 phases ( xi ) pre insulated mid span joint suitable for 25 mm2 neutral messenger ( xii ) pre insulated mid span joint suitable for 35 mm2 neutral messenger ( xiii ) pre insulated mid span joint suitable for 50 mm2 neutral messenger ( xiv ) insulation piercing connector for db charging ( xv ) insulation piercing connector branching suitable for t joints ( xvi ) piercing connector for lt ab cable ( xvii ) insulation piercing connector type i ( main 16 95 mm2 & tap 4 50 mm2 ) ( xviii ) insulation piercing connector type ii ( main 16 120 mm2 & tap 16 120 sq mm ) ( xix ) satellite connector ( xx ) lt ab cable accessory, 1.1mtr. stainless steel strap if207 ( 20x0.7 ) ( xxi ) buckle for strap ( xxii ) suspension clamp with eyehook ( xxiii ) suspension clamp suitable for 25 70 sqmm baremessenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxiv ) suspension clamp suitable for 35 95 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxv ) suspension clamp suitable for 95 150 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxvi ) dead end clamp with eyehook ( xxvii ) dead end clamp suitable for 25 70 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxviii ) dead end clamp suitable for 70 95 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxix ) dead end clamp suitable for 95 150 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxx ) dead end clamp assembly suitable upto 25 sq.mm bare messenger ( 01 dead end clamp with bracket, 2 mtr. stainless steel straps, 02 nos. buckles ) ( xxxi ) suspension clamp assembly suitable for 95 mm2 bare messenger ( 01 nos. suspension clamp with bracket, 2 mtr. stainless stell straps 02 nos. buckles ( xxxii ) service main anchor clamp for proper support of service cable ( 4mm2 and 10 mm2 ) ( xxxiii ) eye hook ( xxxiv ) stainless steel strip of 20mmx1mmx1000mm with buckle clip fabricated items ( i ) hot dip galvanized fabricated iron material for 33 kv line, lt line & dss ( ii ) 33 kv pole top bracket 50x10 mm flat [ galvanized ] ( 2.5 kgs. ) ( iii ) 33 kv pole top bracket 65x65x6 mm [ galvanized ] ( 3.58 kgs. ) ( iv ) 33 kv pole top bracket [ non galvanized ] ( 2.9 kgs. ) ( v ) 11kv pole top bracket 50x8 mm [ galvanized ] ( 2.2 kgs. ) ( vi ) 11 kv pole top bracket 50x8 mm ( f type ) [ non galvanized ] ( 2.2 kgs, ) ( vii ) 11 kv f clamp / bracket ( 2.1 kgs. ) ( viii ) 11 kv fish plate ( 1.6 kgs. ) ( ix ) 33 kv fish plate ( for st pole 13 mtr. ) ( 3 kgs, ) ( x ) 33kv v cross arm for ( 100x50x6 mm ) [ galvanized ] ( 19.7 kgs. ) ( xi ) 33 kv v cross arm ( 100x 50x 6 mm ) [ non galvanized ] ( 19.7 kgs. ) ( xii ) 33 kv dp special type v cross arm [ galvanised ] ( 21 kgs. ) ( xiii ) 11kv v cross arm ( 100x50x6 mm ) , [ galvanized ] ( 16 kgs. ) ( xiv ) 11kv v cross arm ( 75x40x6 mm ) , [ galvanized ] ( 14.6 kgs. ) ( xv ) 11 kv v cross arm ( 75 x 40 x6 mm ) [ non galvanized ] ( 14.6 kgs. ) ( xvi ) ms angle ( 65x65x6 mm ) for guarding of 33 kv [ galvanized ] ( 16 kgs. ) ( xvii ) ms angle ( 65x65x6 mm ) for guarding of 11 kv [ galvanized ] ( 13.6 kgs. ) ( xviii ) ms angle ( 65x65x6 mm ) for guarding of 33 kv, 11 kv, l.t line [ non galvanized ] ( 13.6 kgs. ) ( xix ) top channel set ( 100x50x6 mm ) 3200 mm length [ galvanized ] ( 66.2 kgs. ) ( xx ) top channel set ( 100x50x6 mm ) [ non galvanized ] ( 66.2 kgs. ) ( xxi ) ms channel for ab switch ( 100x50x6 mm ) [ galvanized ] ( 28.16 kgs. ) ( xxii ) ms channel ab switch ( 100x50x6 mm ) [ non galvanized ] ( 28.16 kgs. ) ( xxiii ) 33kv d p channel ( 100x50x6 mm ) 3150 mm long [ galvanized ] ( 65.2 kgs. ) ( xxiv ) 33kv d p channel ( 100x50x6 mm ) 2200 mm long [ galvanized ] ( 45.5 kgs. ) ( xxv ) 33kv d p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] ( 26.9 kgs. ) ( xxvi ) 33 kv d.p channel ( 100x50x6 mm ) 1.3 meter [ non galvanized ] ( 26.9 kgs. ) ( xxvii ) 11kv d p channel ( 75x40x6 mm ) [ galvanized ] ( 41.3 kgs. ) ( xxviii ) 11kv d.p channel ( 75x40x6mm ) [ non galvanized ] ( 41.3 kgs. ) ( xxix ) transformer base channel ( 100x50x6 mm ) [ galvanized ] ( 52.63 kgs. ) ( xxx ) transformer base channel ( 100x50x6 mm ) [ non galvanized ] ( 52.63 kgs. ) ( xxxi ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ galvanized ] ( 52.3 kgs. ) ( xxxii ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ non galvanized ] ( 52.3 kgs. ) ( xxxiii ) belting angle a ( 65x65x6 mm ) [ galvanized ] ( 31 kgs. ) ( xxxiv ) belting angle b ( 65x65x6 mm ) [ galvanized ] ( 28 kgs. ) ( xxxv ) back clamp ( 50x6 mm ) for v xrm & & top bracket for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvi ) back clamp ( 50x8 mm ) for guarding angle for 13 mtr. stp [ galvanized ] ( 3.2 kgs. ) ( xxxvii ) back clamp ( 50x8 mm ) for guarding angle for 9 mtr. psc pole [ galvanized ] ( 3 kgs. ) ( xxxviii ) back clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 3.2 kgs. ) ( xxxix ) back clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 3.2 kgs. ) ( xl ) back clamp ( 50x8 mm ) for v xrm & top bracket for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xli ) back clamp ( 50x6 mm ) for v arm & top bracket 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( xlii ) back clamp ( 50x6 mm ) for 9mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( xliii ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( xliv ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( xlv ) back clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 2 kgs. ) ( xlvi ) back clamp ( 50x6 mm ) for tublar pole [ non galvanized ] ( 2 kgs. ) ( xlvii ) support clamp for v cross arm for 60kg rail pole [ galvanized ] ( 1.6 kgs. each ) ( xlviii ) support clamp for v cross arm for 60kg rail pole [ non galvanized ] ( 1.6 kgs. each ) ( xlix ) support clamp for v cross arm for 9 mtr 400kg psc pole [ galvanized ] ( 1.2 kgs. each ) ( l ) support clamp for v cross arm for 9 mtr 400kg psc pole [ non galvanized ] ( 1.2 kgs. each ) ( li ) support clamp for v cross arm for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. each ) ( lii ) support clamp for v cross arm for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. each ) ( liii ) support clamp for v cross arm for tublar pole [ galvanized ] ( 1.4 kgs. each ) ( liv ) support clamp for v cross arm for tublar pole [ non galvanized ] ( 1.4 kgs. each ) ( lv ) back clamp a for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvi ) back clamp b for belting angle ( 50x8 ) ( 1.872 kgs. each ) ( lvii ) back clamp for 33 kv dp special type v cross arm [ galvanised ] ( 3 kgs. each ) ( lviii ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ galvanized ] ( 3.7 kgs. ) ( lix ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ non galvanized ] ( 3.7 kgs. ) ( lx ) clamp for top channel 50x6 mm flat for 60kg rail pole [ galvanized ] ( 2.8 kgs. ) ( lxi ) clamp for top channel 50x6 mm flat for 60kg rail pole [ non galvanized ] ( 2.8 kgs. ) ( lxii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ galvanized ] ( 3 kgs. ) ( lxiii ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ non galvanized ] ( 3 kgs. ) ( lxiv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ galvanized ] ( 2.8 kgs. ) ( lxv ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ non galvanized ] ( 2.8 kgs. ) ( lxvi ) clamp for top channel 50x6 mm flat for tublar pole [ galvanized ] ( 2 kgs. ) ( lxvii ) clamp for top channel 50x6 mm flat for tublar pole [ non galvanized ] ( 2 kgs. ) ( lxviii ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 2.4 kgs. ) ( lxix ) clamp for ab switch base channel ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 2.4 kgs. ) ( lxx ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( lxxi ) clamp for ab switch base channel ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( lxxii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( lxxiii ) clamp for ab switch base channel ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( lxxiv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ galvanized ] ( lxxv ) clamp for ab switch base channel ( 50x6 mm ) for tublar pole [ non galvanized ] ( lxxvi ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ galvanized ] ( 19.3 kgs. ) ( lxxvii ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ non galvanized ] ( 19.3 kgs. ) ( lxxviii ) clamp ( 50 x 6 mm ) for transformer base channel [ galvanized ] ( 3.2 kgs. ) ( lxxix ) clamp ( 50 x 6 mm ) for transformer base channel [ non galvanized ] ( 3.2 kgs. ) ( lxxx ) clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] ( 1.872 kgs. ) ( lxxxi ) clamp ( 50 x 6 mm ) for transformer belting [ non galvanized ] ( 1.872 kgs. ) ( lxxxii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] ( 1.872 kgs. ) ( lxxxiii ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ non galvanized ] ( 1.872 kgs. ) ( lxxxiv ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 60kg rail pole [ galvanized ] ( 2.25 kgs. each ) ( lxxxv ) d.p channel support clamp ( 50x6 mm ) ) for 60kg rail pole [ non galvanized ] ( 2.25 kgs. each ) ( lxxxvi ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.5 kgs. each ) ( lxxxvii ) d.p channel support clamp ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.5 kgs. each ) ( lxxxviii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.1 kgs. each ) ( lxxxix ) d.p channel support clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ nongalvanized ] ( 1.1 kgs. each ) ( xc ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ galvanized ] ( 4.5 kgs. each ) ( xci ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ non galvanized ] ( 4.5 kgs. each ) ( xcii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ galvanized ] ( 1.92 kgs. ) ( xciii ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( xciv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( xcv ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( xcvi ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( xcvii ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( xcviii ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ galvanized ] ( 1.8 kgs. ) ( xcix ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ non galvanized ] ( 1.8 kgs. ) ( c ) 33kv cross bracing for d p structure ( 50x50x6 ) [ galvanized ] ( 64.3 kgs. ) ( ci ) 33 kv cross bracing for dp channel [ non galvanized ] ( 64.3 kgs. ) ( cii ) 11 kv cross bracing for d p structure [ galvanized ] ( 51.7 kgs. ) ( ciii ) 11 kv cross bracing for d p structure [ non galvanized ] ( 51.7 kgs. ) ( civ ) clamp for cross bracing set of 2 pair for 60kg rail pole [ galvanized ] ( 1.872 kgs. each ) ( cv ) clamp for cross bracing set of 2 pair for 60kg rail pole [ non galvanized ] ( 1.872 kgs. each ) ( cvi ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ galvanized ] ( 1.3 kgs. ) ( cvii ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ non galvanized ] ( 1.3 kgs. ) ( cviii ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole [ galvanized ] ( 1.2 kgs. ) ( cix ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole non [ galvanized ] ( 1.2 kgs. ) ( cx ) clamp for cross bracing set of 2 pair for tublar pole [ galvanized ] ( 1.75 kgs. ) ( cxi ) clamp for cross bracing set of 2 pair for tublar pole [ non galvanized ] ( 1.75 kgs. ) ( cxii ) support clamp for cross bracing for 60kg rail pole [ galvanized ] ( 2.5 kgs. each ) ( cxiii ) support clamp for cross bracing for 60kg rail pole [ non galvanized ] ( 2.5 kgs. each ) ( cxiv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ galvanized ] ( 2.33 kgs. each ) ( cxv ) support clamp for cross bracing for 9 mtr 400kg psc pole [ non galvanized ] ( 2.33 kgs. each ) ( cxvi ) support clamp for cross bracing for 8 mtr 200kg psc pole [ galvanized ] ( 1.68 kgs. each ) ( cxvii ) support clamp for cross bracing for 8 mtr 200kg psc pole [ non galvanized ] ( 1.68 kgs. each ) ( cxviii ) support clamp for cross bracing for tublar pole [ galvanized ] ( 2.1 kgs. each ) ( cxix ) support clamp for cross bracing for tublar pole [ non galvanized ] ( 2.1 kgs. each ) ( cxx ) angle / side stay clamp ( 50x8 mm ) for 13 mtr. stp pole [ galvanized ] ( 2.1 kgs. ) ( cxxi ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( 1.92 kgs. ) ( cxxii ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( 1.92 kgs. ) ( cxxiii ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( 1.92 kgs. ) ( cxxiv ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( 1.92 kgs. ) ( cxxv ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( 1.08 kgs. ) ( cxxvi ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( 1.08 kgs. ) ( cxxvii ) angle / side stay clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( 1.92 kgs. ) ( cxxviii ) angle / side stay clamp ( 50 x 6 mm ) for tublar pole [ non galvanized ] ( 1.92 kgs. ) ( cxxix ) clamp for g.i. pipe ( 2.02 kgs. ) ( cxxx ) gi flat ( 75x6 mm ) [ galvanized ] ( 1.1 kgs. ) ( cxxxi ) ms flat ( 75x6 mm ) [ non galvanized ] ( 1.1 kgs. ) ( cxxxii ) earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] ( 1.8 kgs. ) ( cxxxiii ) earth clamp for earthwire ( 50 x 6 mm ) [ non galvanized ] ( 1.8 kgs. ) ( cxxxiv ) ms angle for lt distribution bus ( 50x50x6 mm ) [ galvanized ] ( cxxxv ) ms angle for l t distribution bus ( 50x50x6 mm ) [ non galvanized ] ( cxxxvi ) lt bracket vertical formation ( cxxxvii ) lt bracket for tapping point ( cxxxviii ) lt angle bracket ( 50x50x6 mm ) [ galvanized ] ( cxxxix ) lt angle bracket ( 50x50x6 mm ) [ non galvanized ] ( cxl ) pole clamp for i hook b type ( 0.8 kgs. each ) ( cxli ) lt back clamp ( 50 x 6 mm ) for lt angle [ galvanized ] ( 0.55 kgs. each ) ( cxlii ) lt back clamp ( 50 x 6 mm ) for lt angle [ non galvanized ] ( 0.55 kgs. each ) ( cvliii ) u clamp ( 40 x 6 mm ) [ galvanized ] ( 1.46 kgs. ) ( clxiv ) u clamp ( 40 x 6 mm ) [ non galvanized ] ( 1.46 kgs. ) ( clxv ) 50 x 6 mm galvanized gi flat ( risers ) ( clxvi ) 25 x 3 mm galvanized gi flat ( risers ) fuse ( i ) 11 kv d.o. fuse unit ( polymer type ) ( ii ) 33 kv d.o. fuse unit ( polymer type ) ( iii ) 33 kv h.g. fuse unit ( polymer type ) ( iv ) 11 kv h.g. fuse unit ( polymer type ) electrical conduit ( pipes ) ( i ) gi pipe 4 medium duty ( b class ) ( ii ) gi pipe 6 medium duty ( b class ) ( iii ) gi pipe 8 medium duty ( b class ) ( iv ) hume pipe rcc pipe 100 mm ( np2 class ) ( v ) hume pipe rcc pipe 150 mm ( np2 class ) ( vi ) hume pipe rcc pipe 200 mm ( np3 class ) ( v ) hdpe pipe 110 mm / 4 pe 63 grade ( vi ) hdpe pipe 160 mm / 6 pe 63 grade ( vii ) hdpe pipe 200 mm / 8 pe 63 grade heat shrinkable kit ( i ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 ( ii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 300 mm2 ( iii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 240mm2 ( iv ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 185 mm2 ( v ) 33 kv 3 core heat shrikable straight through cable jointing kit for 150 95 mm2 ( vi ) 33 kv 3 core heat shrikable straight through cable jointing kit for 70 35 mm2 ( vii ) 33 kv termination kit for 1core x 400mm2 ( viii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 400mm2 ( ix ) 33 kv 3 core heat shrinkable out door type cable termination kit for 300 mm2 ( x ) 33 kv 3 core heat shrinkable out door type cable termination kit for 240 mm2 ( xi ) 33 kv 3 core heat shrinkable out door type cable termination kit for 185 mm2 ( xii ) 33 kv 3 core heat shrinkable out door type cable termination kit for 120 mm2 ( xiii ) 33 kv 3 core heat shrikable out door cable termination kit for 95 70 mm2 ( xiv ) 33 kv 3 core heat shrikable indoor cable termination kit for 400mm2 ( xv ) 33 kv 3 core heat shrikable indoor cable termination kit for 300 mm2 ( xvi ) 33 kv 3 core heat shrikable indoor cable termination kit for 240 mm2 ( xvii ) 33 kv 3 core heat shrikable indoor cable termination kit for 185 mm2 ( xviii ) 33 kv 3 core heat shrikable indoor cable termination kit for 120 mm2 ( xix ) 33 kv 3 core heat shrikable indoor cable termination kit for 95 70 mm2 ( xx ) 33 kv 3 core heat shrikable indoor cable termination kit for 50 25 mm2 ( xxi ) in door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxii ) out door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( xxiii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 400 mm2 ( xxiv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 300 mm2 ( xxv ) 11 kv 3 core heat shrinkable straight through cable jointing kit 240 mm2 ( xxvi ) 11 kv 3 core heat shrinkable straight through cable jointing kit 185 mm2 ( xxvii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 95 150 mm2 ( xxviii ) 11 kv 3 core heat shrinkable straight through cable jointing kit 70 35 mm2 ( xxix ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 400 mm2 ( xxx ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 300 mm2 ( xxxi ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 240 mm2 ( xxxii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 120 185 mm2 ( xxxiii ) 11 kv 3 core heat shrinkable indoor cable jointing / termination kit 95 50 mm2 ( xxxiv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 400 mm2 ( xxxv ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 300 mm2 ( xxxvi ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 240 mm2 ( xxxvii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 120 185 mm2 ( xxxviii ) 11 kv 3 core heat shrinkable outdoor cable jointing / termination kit 95 50 mm2 ug cables related material ( i ) pillar box cum consumer service distribution box one time lock system ( 1 no. 3 ph 4 wire incoming and 5 nos. 3ph 4 wire outgoing ) ( ii ) cable marker ( metal ) ab switch contact ( i ) male female contact of 33 kv ab switch 600 630 amp ( ii ) male female contact of 33 kv ab switch 400 amp ( iii ) male female contact of 33 kv ab switch 200 amp ( iv ) male female contact of 11 kv ab switch 800 amp ( v ) male female contact of 11 kv ab switch 600 amp ( vi ) male female contact of 11 kv ab switch 400 amp ( vii ) male female contact of 11 kv ab switch 200 amp testing equipment ( i ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt whole current single phase meters up to 60a ( ii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt 3 phase & ct operated energy meters ( iii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh for ht+ : to test meters suitable for ht, 3 phase, 3 wire and 4 wire systems ( iv ) eh ii chain electric hoist ( capacity 1 ton, standard lift 3 mtr ) with 1.5 hp motor ( v ) electronic weighing machine with 1.2x1.2 mtr. platform, suitable for weighing limit upto 2 tons ( vi ) electronic weighing machine with 2x2 mtr. platform, suitable for weighing limit upto 4 tons ( vii ) earth tester 200 amp. 2000 ohm ( digital ) ( viii ) 500 v megger ( ix ) 2.5 / 5 kv megger ( mannual ) ( x ) digital clamp meter ( meco 3150 ) ( xi ) digital tong tester ( 1000 amp., 500 v ) with associated accessories. ( xii ) digital multi meter ( 10 amp along with ma range ) ( xiii ) 2.5 kv motorised with range up to 20000 mega ohms ( xiv ) 2.5 kv motorised cum manual with range up to 20000 mega ohms ( xv ) 5 kv motorised with range up to 100000 mega ohms ( xvi ) 5 kv motorised cum manual with range up to 100000 mega ohms tool kit ( i ) adhesive insulation tape ( ii ) high temperature tape ( iii ) dicharge rod for 33 kv / 11kv ( iv ) screw driver set 840 ( v ) screw driver set 935 ( vi ) neon tester 813 ( vii ) hammer 200 gm ( viii ) hack saw frame ( ix ) hack saw blades ( x ) adjustable spanner ( xi ) wire stripper ( xii ) combinational plier ( xiii ) side cutting plier ( xiv ) measuring tape ( xv ) hand drill machine ( xvi ) punch ( xvii ) knife ( xviii ) spanner set ( xix ) tool bag ( xx ) nose plier ( xxi ) drill bit 3 / 10 concrete ( jk ) ( xxii ) chain pulley 5ton with 15 meter chain ( xxiii ) max pulley 10 ton civil works ( i ) opc cement scada related materials ( a ) scada server ( i ) fep server with interface switches for rtus and frtus ( ii ) isr server { data server } ( iii ) nms server { dms server } ( iv ) dts server ( only at ranchi ) ( v ) developmental server ( vi ) communication server ( vii ) web / directory server ( viii ) workstation with dual tft monitors ( ix ) led based video projection system with 2x3 module configuration with each module at least 67 diagonal with common projector ( x ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 1f ) ( xi ) 33 kv or 11 kv control and relay panel, scada compatable for transformer protection ( it ) with o / c +e / f + diff relay ( xii ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 2f ) ( xiii ) buchholz relay contact ( xiv ) minimum oil gauge ( xv ) scada compatible winding temp. indicator ( xvi ) scada compatible oil temp. indicator ( xvii ) rtu base equipment comprising panels, racks, sub racks, powe suppy modules, cpu, analog and digital input control output modules, interfacing mft using rs 485 modbus protocol and 2 ethernet ports + 4 serial ports ( rs232 / 485 ) , required a d converters and all other accessories required ( xviii ) dc voltage transducer ( xix ) rtu base and foundation ( base should be capable of withstanding 200 kg. load ) ( xx ) multi function transducers ( 5 amps, 110 v with rs 485 modbus communication protocol ) ( xxi ) type a frtu for 5 way rmus ( xxii ) type a frtu for 4 way rmus ( xxiii ) type b frtu for 3 way rmus ( xxiv ) type c frtu for 2 way rmus ( xxv ) routers 230 v ac, 2 ge ports, 48xfe, wan speed 200 mbps ( xxvi ) ethernet switch ( xxvii ) 2 mbps vpn link for connectivity for s / s with scada control center ( xxviii ) ldms ( xxix ) 2 kva ups ( for ldms ) with 160 ah battery, 72 v battery set ( xxx ) gsm / gprs modem along with accessories ( xxxi ) b / w laser printer for ldms ( xxxii ) 48 v dc power supply system based on smps for rtu & comm. equipment with 80 ah battery ( xxxiii ) cat 6 cable ( xxxiv ) ldms software ( xxxv ) numerical relay scada compatible for power transformer protection ( xxxvi ) numerical relay scada compatible for 33kv and 11 kv feeder protection ( xxxvii ) mcu module card ( xxxviii ) power module card ( xxxix ) di card ( xl ) do card ( xli ) ai card ( xlii ) com 6 card ( xliii ) rmu 3 way ( 1 incomer, 1 outgoing and 1 breaker ) scada compatible ( xliv ) rmu 5 way ( 1 incomer, 1 outgoing and 3 breakers ) scada compatible ( xlv ) 11 kv sectionalizer ( xlvi ) 11 kv auto reclosure ( xlvii ) gprs / cdma / edge / 3g modem ( xlviii ) heavy duty relay for cb trip / close ( 48 v dc, 2 no, 1 nc ) ( xlix ) 48 v dcps at rtu locations along with vrla batteries ( l ) 11 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( li ) 33 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( b ) storage & backup devices ( i ) external raid mass storage device ( for 2 months online backup ) ( ii ) external dat drive ( c ) switches ( i ) layer ii switch ( scada / dms lan ) ( 48 ports ) ( ii ) layer switch ( planning & development system lan ) ( 24 ports ) ( d ) other active devices ( i ) gps time synchronization system ( ii ) time, day & date digital displays ( e ) printers ( i ) a3 color inkjet printer ( ii ) b / w laser printer ( iii ) color laser printer ( f ) security system ( dmz ) ( i ) web server with load balancing ( ii ) firewall & network ids / ips in pair ( 2 nos. ) ( g ) cabling system ( i ) cable, jacks, hubs, etc. ( ii ) acdb for control centre ( iii ) kvm switch ( iv ) panels ( h ) software for control centre ( i ) scada software ( ii ) isr software ( iii ) dms software ( iv ) dts software ( v ) developmental software ( vi ) network management software ( viii ) gis adaptor / engine for importing data from gis system under it system ( i ) form: f 4: rtu:rtu type b 33 / 11 kv sub stations ( i ) rtu base equipment comprising panels, racks, sub racks, power supply modules, cpu, analog and digital input control output modules, interfacing equipments for interfacing mfts using rs 485 modbus protocol and 2 eathernet ports, required a d converters & all other required items / accessories including complete wiring for all modules for locations mentioned for type b rtus ( ii ) multifunction transducers ( mfts ) ( iii ) contact multiplying relays ( cmrs ) ( iv ) heavy duty relays ( hdrs ) for cb trip / close and rise and lower of oltc ( v ) weather transducer wind speed ( vi ) weather transducer rainfall ( vii ) weather transducer humidity ( viii ) weather transducer temperature ( ix ) weather transducer wind direction ( x ) router for rtus at dc power supply ( xi ) oltc transducers ( xii ) dc current transducer ( xiii ) dc voltage transducer ( xiv ) acdb with sufficient mccbs ( j ) test equipments for rtu ( i ) rtu database configuration & maintenance software tool ( ii ) master station cum rtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( k ) form: f 5:frtu / frtus ( i ) type a frtu for 5 way rmus ( ii ) type a1 frtu for 4 way rmus ( iii ) type b frtu for 3 way rmus ( iv ) type c frtu for sectionalizers ( v ) mfts ( vi ) contact multiplying relays ( cmrs ) ( vii ) heavy duty relays for cb trip / close ( l ) test equipments for frtu ( i ) frtu database configuration & maintenance software tool ( ii ) master station cum frtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( m ) f4: gprs / cdma / edge / 3gmodems ( i ) gprs ( n ) form: f 7: auxiliary power supply system ( aps ) ( i ) 20 kva ups ( 1+1 ) with vrla batteries to give 4 hrs back up ( ii ) dc power supply ( dcps ) system based on smps ( for 20 a load plus charging current@10% capacity ) with vrla batteries to give 4 hrs back up. ( iii ) 2 kva ups for rtu locations / ldms ( iv ) 48 v dcps at rtu locations along with vrla batteries ( v ) 24 / 48 v dcps for frtu locations along with vrla batteries safety equipment ( i ) rechargeable led hand torch ( ii ) safety helmet pvc ( iii ) safety shoes ( electrical safety ) ( iv ) rubber hand gloves ( 1.1kv ) commander ( v ) safety double adjustable belts ( karam ) ( vi ) safety items as per the requirement of electrical inspector as under first aid box, shock treatment chart, rubber matts 8 mm thick, 4 fire buckets with sand & m.s. hooks / stand, helmet, hand gloves and, fire extinguisher ( 2 nos ) fire extinguishers ( i ) i kg dry chemical powder ( map 50% ) ; fire rating : 1a, 8b ( ii ) 2 kg dry chemical powder ( map 50% ) ; fire rating: 2a, 8b ( iii ) 4 kg dry chemical powder ( map 50% ) ; fire rating : 2a, 21b ( iv ) 6 kg dry chemical powder ( map 50% ) ; fire rating: 3a, 34b ( v ) 9 kg dry chemical powder ( map 50% ) fire rating: 4a, 55b ( vi ) 6 ltr water type; fire rating : 2a ( vii ) 9 ltr water type, fire rating: 3a ( viii ) 6 ltr mechanical foam type, fire rating: 2a, 21b ( ix ) 9 ltr mechanical foam type, fire rating: 4a, 34b ( x ) 2 kg carbon dioxide type, fire rating: 8b ( xi ) 3 kg carbon dioxide type, fire rating: 13b ( xii ) 4.5 kg carbon dioxide type, fire rating: 21b ( xiii ) 6.5 kg carbon dioxide type, fire rating: 55b ( xiv ) 9 kg carbon dioxide type, fire rating: 70b ( xv ) 22.5 kg carbon dioxide type, fire rating: 70b ( xvi ) gas pressure ctc fire extinguisher ( xvii ) fire buckets ( capacity 10 ltrs. ) feeder pillar / smdb / distribution board ( i ) lt mini feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) ( ii ) smdb ( 1 in, 3 out ) with housing 5 nos 20 amp spn mcb, ( iii ) tpn distribution board 12 way, 50 amp tpn mcb, ( iv ) tpn distribution board 12 way, 100 amp tpn mcb, ( v ) tpn distribution board 12 way, 150 amp tpn mcb, ( vi ) lt feeder piller box for 1 phase 8 connection made of m.s.sheet. ( vii ) lt feeder piller box for 1 phase 12 connection made of m.s.sheet. ( viii ) lt feeder piller box for 3 phase 4 connection made of m.s.sheet. ( ix ) lt feeder piller box for 3 phase 8 connection made of m.s.sheet. ( x ) lt feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) aluminium end terminal lugs 10 sq mm 16 sq mm 25 sq mm 32 sq mm 50 sq mm 70 sq mm 95 sq mm 120 sqmm 150 sq mm 185 sq mm 225 sq mm 240 sq mm 300 sqmm 400 sq mm other misc. equipment ( i ) earthing g.i.strip ( 65x6 ) mm2 ( ii ) rain coat ( iii ) rubber mat along length of pannel ( iv ) aluminium pipe 40 mm dia ( v ) 400 watt / 250 v hpsv lamp fitting complete for 33 / 11 kv pss yard lightining ( vi ) 30 v 80 ah battery charging unit complete with battery and stand ( vii ) 30 volts 100 ah lead acid battery with battery charger and stand ( viii ) 30v, 40 amp. float cum boost battery charger with full wave rectification for 230 v, 1 phase, 50 hz ac input supply as per technical specifications. ( ix ) polycarbonate seal bit ( x ) sticker seal with hologram ( xi ) earth knob ( xii ) ms earth mat for switch yard ( xiii ) rail piece 44.64kg / m 6.92 meter long for power transformer ( xiv ) aluminium binding wire ( xv ) gi wire no. 6 / 8 / 10 ( xvi ) t / c fuse wire 12 / 14 / 16 / 18 / 22 / 28 / 32 swg ( xvii ) m s nuts & bolts of different size ( xviii ) galvanised nuts & bolts ( assorted size ) ( xix ) jointing sleeves ( alumnium ) suitable for 34 / 55 sq.mm ( xx ) jointing sleeves ( alumnium ) suitable for 70 100 sq.mm ( xxi ) jointing sleeves ( alumnium ) suitable for 150 232 sq.mm ( xxii ) anticlimbing device ( barbed wire ) 2x12 swg ( xxiii ) al paint ( xxiv ) red oxide paint ( xxv ) lt phase seperator ( xxvi ) 3 mm thick ms plate with weight of 0.36 kg asset tag ( xxvii ) transformer oil ( ehv grade ) ( xxviii ) natural ester oil ( xxix ) c wedge connector for 0.2sq panther conductor ( nominal aluminum area 200mm2 ) ( xxx ) fault locator machine for ug cables ( flc ) without vehicle ( xxxi ) transformer oil testing kit ( 220 / 230 ac ) ( xxxii ) transformer oil filter machine ( 500 gph ) ( xxxiii ) supply & installation of battery bank of 2 volt 300 ah vrla cells mounted on rack with insulated copper terminal connectors & nut boly ( each set of battery bank consist of 204 nos. vrla cells ) ( b ) furniture ( i ) thrive mid back revolving chair size:75cm ( w ) x 75cm ( d ) x 100cm 109cm ( h ) x 45cm 54cm ( seat height ) . ( ii ) thrive non revolving visitor chair size:63.5cm ( w ) x 59.5cm ( d ) x 97.5cm ( h ) x 42.5cm ( seat height ) . ( iii ) regency non revolving visitor chair with armrest size:59cm ( w ) x 63cm ( d ) x 81.5cm ( h ) x 45cm ( seat height ) . ( iv ) regency mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 78.5cm 90.5cm ( h ) x 44.2cm 54.2cm ( seat height ) . ( v ) bravo mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 85.5cm 97.5cm ( h ) x 42.5cm 54.5cm ( seat height ) . ( vi ) high back revolving chair size:76.1cm ( w ) x 76.1cm ( d ) x 114.5cm 131.5cm ( h ) x 44.5cm 54.5cm ( seat height ) . ( vii ) non revolving visitor chair size:60.9cm ( w ) x 64.7cm ( d ) x 98.2cm ( h ) x 46.2cm ( seat height ) . ( viii ) very high back revolving chair size:77cm ( w ) x 77cm ( d ) x 134.9cm 143.9cm ( h ) x 49.9cm 58.9cm ( seat height ) . ( ix ) non revolving visitor chair size:59cm ( w ) x 68.5cm ( d ) x 89.5cm ( h ) x 46.5cm ( seat height ) . ( x ) unlearn single seater cpu / laptop table for computer training hall size: 90cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xi ) unlearn 2 seater laptop table for meeting hall size:135cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xii ) unlearn 4 seater laptop table for meeting hall size:270cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xiii ) talk unitised 4 seater round table size:120cm dia x 75cm ( h ) ( xiv ) talk modular conference table size:67.5cm ( w ) x 60cm ( d ) x 75cm ( h ) ( xv ) enterprise table with cpu hanger size:165cm ( w ) x 90cm ( d ) x 72.8cm ( h ) ( xvi ) insight table for library size:180cm ( w ) x 90cm ( d ) x 74cm ( h ) ( xvii ) versatila v2 table for faculty sitting area size:150cm ( w ) x 89.4cm ( d ) x 75cm ( h ) ( xviii ) executive table with right unit and pedestal size:180cm ( w ) x 210cm ( d ) x 75cm ( h ) ( xix ) main desk table size: 180cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xx ) back unit for impress desk table size: 221.5cm ( w ) x 41cm ( d ) x 200cm ( h ) ( xxi ) display unit tv cabinet walnut color size: 140cm ( w ) x 40cm ( d ) x 75.4cm ( h ) ( xxii ) time out 4 seater pu coated dining table size: 113.5cm ( w ) x 117.5cm ( d ) x 75cm ( h ) ( xxiii ) café chair without armrest size: 52.5cm ( w ) x 55.8cm ( d ) x 84.5cm ( h ) x 45cm ( seat height ) ( xxiv ) apple dining table 6 seater glass top size: 160cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xxv ) silver dining chair size: 44.5cm ( w ) x 41.5cm ( d ) x 96cm ( h ) ( xxvi ) dark walnut dining chair size: 45cm ( w ) x 45cm ( d ) x 95cm ( h ) ( xxvii ) coffee table walnut color size: 100cm ( w ) x 65cm ( d ) x 45cm ( h ) ( xxviii ) 3 seater leatherite sofa size: 205.5cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxix ) 2 seater leatherite sofa size: 100cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxx ) single seater leatherite sofa size: 86cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxxi ) plain almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxii ) glass door storwel almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxiii ) single sided wood & steel book rack base unit size:90cm ( w ) x 30cm ( d ) x 189cm ( h ) ( xxxiv ) all steel periodical display rack size:90cm ( w ) x 45cm ( d ) x 183cm ( h ) ( xxxv ) 4 door bookcase ( without top ) size:91.4cmw x 32cm ( d ) x 174.2cm ( h ) ( xxxvi ) white board 4ft. x 3ft. with stand ( xxxvii ) l shaped workstation made of 19mm thk white mdf board with pvc edges.size:1800mm ( l ) + 1200mm ( l ) x 600mm ( d ) x 1200mm ( h ) meter box ( i ) poly carbonate weather proof outdoor type meter cover boxes for single phase meter size 315mm x 265mm x 130mm along with zinc plated clamps ( ii ) poly carbonate weather proof outdoor type meter cover boxes for three phase meters 445mm x 345mm x 170mm along with zinc plated clamps ( iii ) deep drawn m.s. sheet weather proof outdoor type meter cover box for single phase meter size 300mm x 250mm x 160mm along with zinc plated clamps ( iv ) deep drawn m.s. sheet weather proof outdoor type meter cover box for three phase meter size 500mm x 300mm x 160mm along with zinc plated clamps ( v ) metal box of ct 800 / 5 amp ( vi ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 400 / 5a ( vii ) meter box ( viii ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 800 / 5a ( ix ) metal box of ct 400 / 5 amp gas insulated switchgear s / s ( i ) 30kv, 10ka, metal oxide, station class, surge arrester ( scada compliant ) ( for 33kv incoming line, ht side of 2nos. power transformers and 33 / 0.433kv station transformer ) outdoor type with surge counter. ( ii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) with: breaker: 36kv, 1250 a, ( 25ka s.c. rating ) , 3 ph, indoor type breaker ( with 30v dc tripping / closing coil and associated control ) along with marshalling box, terminal connectors and required accessories complete as per applicable ts ct:36kv, 1 ph, 25ka ( 800^00 200 / 1 1 1 a ) indoor type current transformer, having three secondary cores ( protection & metering & current differential protection ) along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set = 3 nos. ) pts: 36kv, 1 ph, 33kv / 110 v, single core outdoor type potential transformer along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set= 3 nos. ) and digital ammeter / voltmeter / energy meter, o / c and e / f relay etc. the cable chamber shall have 3 nos., 20kv, 10 ka distribution class valve type lightning arresters and isolators of capacity given in ts. for feeder protection ( iii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between gis and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for bus coupler protection. ( iv ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, 3 phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 1a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between breakers and indoor control panel and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static tri vector energy meter, relays and accessories complete for power transformer protection. ( v ) 11 kv indoor gas insulated switch gear panel ( scada compliants ) consisting of 1250 a, 25ka for 3 seconds, 3 ph, indoor type breaker along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for transformer protection ( vi ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for bus coupler protection ( vii ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for feeder protection ( viii ) remote terminal unit ( rtu ) & accessories with pc & connections with 30 nos. analog points for voltage, frequency, mw, mvar ; 3 positional analog points for oltc and 28 digital points for breaker and isolator status. ( ix ) flexible cu. earth bond 1cm dia & 500mm long, both end provision of socket suitable for m 16 bolts. ( x ) g 3 gi beam ( 5.05mtr long, consisting of 2 nos 150x75 x5.7mm ) for 33kv incoming line ( 2 nos. beam one for surge arrester and other for isolator, nominal unit wt 0.2 mt ) ( xi ) gi spikes with cone and gi ( 2 nos ) base plate 10mm ( 50x2500 mm gi pipe ) ( unit wt=0.04 mt ) ( xii ) 12 kv, 630 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , gang operated isolator along with earth switch and support insulators, operating mechanism, base channel, down pipe and all required accessories complete as per technical specifications, without earth switch for substation transformers. ( xiii ) 60 kg / mtr rail pole pieces 5.4 mts ( 2.7x2 ) 44.62 kg per mtr / transformer ( unit wt=0.240 mt ) ( xiv ) 2 tier 2 rows cable trench ( internal width 1500 mm, depth 680 mm, width 75x75x6 mm support angles fixed rcc column of 250 x 250 mm & with ladder type cable tray ( 45x45x5mm two angles at both side having welded flats of 25x5 mm at a gap of 150mm ) for power & control cable ( xv ) chequerred plate 1000x300x5.6mm thick for cable trench in side control room 12 mtr ( xvi ) overhead hoist beam mounted remote opertated for lifting of equipment of control room, capacity 5 tonnes ( xvii ) 36kv, 800 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , motorised indoor floor mounted off load isolator along with all required accessories complete as per technical specifications, scope of works and approved ( xviii ) external electrification in switch yard area including power receptacles, station yard lighting with 6 nos lighting pole ( fitted with 2x100 watts led flood light ) made of 11 meters high steel tubular poles ( is 2713 part i, ii iii ) of designation 410 – sp 60 and 6 nos light ( 1 x 250 w led ) on structure & control room complete as per technical specifications, approved drawings and scope of the work. ( xix ) internal electrification works of control room comprising of main distribution board, sub distribution boards, copper flexible multi conductor 2.5 sqmm wiring ( for light & fan ) / 4 sqmm wiring ( for power points ) , power and light points, conduits, fan / led lamps / tube fittings, exhaust fans, switches, sockets, 2mm thick, pvc 25mm dia conduits pipes in recess, plugs, miniature circuit breakers, seperate independent earthing ( 2 nos of 40mm gi pipe / 3 m long ) etc as required including dc emergency lighting and auto change over switch as per technical specifcations, approved drawings and scope of work. over head distance to fault locator ( offline ) with signature analyser. a ) accessories & laptop as per latest technical specifications tower line for river crossings ( i ) d type tower for 33kv, 11kv ( double circuit line ) ( 13.56mt each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( ii ) d type tower for 33kv, 11kv ( four circuit line ) ( 15.14mt ) ( double circuit tower +3meter extension each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( iii ) compression type tension hardware fitting for earth wire ( iv ) vibration damper suitable for 7 / 3.15 mm gi earth wire ( v ) 25x500 mm flexible cu. earth bond. covered conductor & accessories ( i ) acsr covered panther conductor ( 200 sq. mm ) ( ii ) acsr covered wolf conductor ( 150 sq. mm ) ( iii ) acsr covered dog conductor ( 100 sq. mm ) ( iv ) mid span joint ( 150 sq mm & 200 sq mm ) ( v ) suspension ties ( ( 150 sq mm & 200 sq mm ) ) ( vi ) tension clamp ( wedge type ) ( ( 150 sq mm & 200 sq mm ) ) ( vii ) insulation piercing connector ( bare to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( viii ) insulation piercing connector ( covered to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( ix ) insulation piercing connector with alumunium bail for earthing ( ( 150 sq mm & 200 sq mm ) ) ( x ) mid span joint ( 100 sq mm & 50 sq mm ) ( xi ) suspension ties ( ( 100 sq mm & 50 sq mm ) ) ( xii ) tension clamp ( wedge type ) ( ( 100 sq mm & 50 sq mm ) ( xiii ) insulation piercing connector ( bare to covered ) ( 100 sq mm & 50 sq mm ) ( xiv ) insulation piercing connector ( covered to covered ) ( 100 sq mm & 50 sq mm ) ( xv ) insulation piercing connector with aluminium bail for earthing ( 100 sq mm & 50 sq mm ) led lights and related items ( i ) led light 190w ( ii ) led light 120w ( iii ) led light 75w ( iv ) led light 40w ( v ) 18 watt led panel bulb with outer 205x205x25 mm sq. and 180x180 mm inner diesel generator sets ( three phase ) with amf panel ( i ) 10kva ( ii ) 20kva ( iii ) 30kva ( iv ) 40kva ( v ) 50kva ( vi ) 62.5kva ( vii ) 82.5kva ( viii ) 100kva ( ix ) 160kva trw related items ( i ) 1 / 2 l.t. brass studs ( ii ) 1 / 2 h.t. brass studs ( iii ) l.t bushing 3347 250 amp ( iv ) l.t. bushing 250 amp ( v ) kraft paper 4 mile ( vi ) insulating paper tap 2.0 mm ( vii ) press board 1 mm ( viii ) bakelite tube 3 / 8x1 / 2 ( ix ) empire sleeving size 4 mm ( x ) r.c. sheet 3 x2x1 / 2 mm ( xi ) inline connector 6 mm ( xii ) cotton tap 1 ( xiii ) r.c. strip ( xiv ) r.c. washer 50x28x2 ( xv ) silicagel breather 200 kva ( xvi ) m.seal ( xvii ) c.i.cap 1 8 1 / 2 ( xviii ) insulating paper top 2.5 mil 20 mm ( xix ) crap paper ( xx ) g.p. thinner ( xxi ) d.a. gray paint ( xxii ) white paint ( xxiii ) nylon washer 3 / 4 ( xxiv ) m.s. plug ( xxv ) l.t. al.strip 6.50x4.50 mm ( xxvi ) dpc aluminum winding wire ( xxvii ) dpc aluminum winding strip ( xxviii ) transformer testing bench panel for 10 kva to 500 kva distribution transformer with its installation & commissioning transformer repairing items ( i ) l.t bushing rod assembly of 750 kva transformer. ( ii ) h.t bushing rod assembly of 750 kva transformer. ( iii ) l.t bushing insulator of 750 kva transformer. ( iv ) h.t bushing insulator of 750 kva transformer. ( v ) l.t bushing gasket set of 750 kva transformer. ( vi ) h.t bushing gasket set of 750 kva transformer. ( vii ) tank gasket set of 750 kva transformer. ( viii ) silica gel breather of 750 kva transformer. ( ix ) arching horn of 750 kva transformer, ( x ) l.t bushing rod assembly of 500 kva transformer ( xi ) h.t bushing rod assembly of 500 kva transformer ( xii ) l.t bushing insulator of 500 kva transformer ( xiii ) h.t bushing insulator of 500 kva transformer ( xiv ) l.t bushing gasket set of 500 kva transformer ( xv ) h.t bushing gasket set of 500 kva transformer ( xvi ) tank gasket set of 500 kva transformer ( xvii ) silica gel breather of 500 kva transformer ( xviii ) arching horn of 500 kva transformer ( xix ) l.t bushing rod assembly of 400 kva transformer ( xx ) h.t bushing rod assembly of 400 kva transformer ( xxi ) l.t bushing insulator of 400 kva transformer ( xxii ) h.t bushing insulator of 400 kva transformer ( xxiii ) l.t bushing gasket set of 400 kva transformer ( xxiv ) h.t bushing gasket set of 400 kva transformer ( xxv ) tank gasket set of 400 kva transformer ( xxvi ) silica gel breather of 400 kva transformer ( xxvii ) arching horn of 400 kva transformer ( xxviii ) l.t bushing rod assembly of 315 kva transformer ( xxix ) h.t bushing rod assembly of 315 kva transformer ( xxx ) l.t bushing insulator of 315 kva transformer ( xxxi ) h.t bushing insulator of 315 kva transformer ( xxxii ) l.t bushing gasket set of 315 kva transformer ( xxxiii ) h.t bushing gasket set of 315 kva transformer ( xxxiv ) tank gasket set of 315 kva transformer ( xxxv ) silica gel breather of 315 kva transformer ( xxxvi ) arching horn of 315 kva transformer ( xxxvii ) l.t bushing rod assembly of 250 kva transformer ( xxxviii ) h.t bushing rod assembly of 250 kva transformer ( xxxix ) l.t bushing insulator of 250 kva transformer ( xl ) h.t bushing insulator of 250 kva transformer ( xli ) l.t bushing gasket set of 250 kva transformer ( xlii ) h.t bushing gasket set of 250 kva transformer ( xliii ) tank gasket set of 250 kva transformer ( xliv ) silica gel breather of 250 kva transformer ( xlv ) arching horn of 250 kva transformer ( xlvi ) l.t bushing rod assembly of 200 kva transformer ( xlvii ) h.t bushing rod assembly of 200 kva transformer ( xlviii ) l.t bushing insulator of 200 kva transformer ( xlix ) h.t bushing insulator of 200 kva transformer ( l ) l.t bushing gasket set of 200 kva transformer ( li ) h.t bushing gasket set of 200 kva transformer ( lii ) tank gasket set of 200 kva transformer ( liii ) silica gel breather of 200 kva transformer ( liv ) arching horn of 200 kva transformer ( lv ) l.t bushing rod assembly of 100 kva transformer ( lvi ) h.t bushing rod assembly of 100 kva transformer ( lvii ) l.t bushing insulator of 100 kva transformer ( lviii ) h.t bushing insulator of 100 kva transformer ( lix ) l.t bushing gasket set of 100 kva transformer ( lx ) h.t bushing gasket set of 100 kva transformer ( lxi ) tank gasket set of 100 kva transformer ( lxii ) silica gel breather of 100 kva transformer ( lxiii ) arching horn of 100 kva transformer ( lxiv ) l.t bushing rod assembly of 63 kva transformer ( lxv ) h.t bushing rod assembly of 63 kva transformer ( lxvi ) l.t bushing insulator of 63 kva transformer ( lxvii ) h.t bushing insulator of 63 kva transformer ( lxviii ) l.t bushing gasket set of 63 kva transformer ( lxix ) h.t bushing gasket set of 63 kva transformer ( lxx ) tank gasket set of 63 kva transformer ( lxxi ) silica gel breather of 63 kva transformer ( lxxii ) arching horn of 63 kva transformer ( lxxiii ) l.t bushing rod assembly of 25 kva transformer ( lxxiv ) h.t bushing rod assembly of 25 kva transformer ( lxxv ) l.t bushing insulator of 25 kva transformer ( lxxvi ) h.t bushing insulator of 25 kva transformer ( lxxvii ) l.t bushing gasket set of 25 kva transformer ( lxxviii ) h.t bushing gasket set of 25 kva transformer ( lxxix ) tank gasket set of 25 kva transformer ( lxxx ) silica gel breather of 25 kva transformer ( lxxxi ) arching horn of 25 kva transformer ab switch repairing item ( i ) jaw of air break switch 600a ( ii ) blade of of air break switch 600a ( iii ) post insulator of air break switch 600a ( iv ) bearing of air break switch 600a ( v ) phase coupling pipe of air break switch 600 a ( vi ) down pipe of air break switch 600 a ( vii ) operating handle of air break switch 600 a ( viii ) operating leaver of air break switch 600 a ( ix ) connector of air break switch 600 a ( x ) arching horn of air break switch 600 a ( xi ) jaw of air break switch 400a ( xii ) blade of of air break switch 400a ( xiii ) post insulator of air break switch 400a ( xiv ) bearing of air break switch 400a ( xv ) phase coupling pipe of air break switch 400 a ( xvi ) down pipe of air break switch 400 a ( xvii ) operating handle of air break switch 400 a ( xviii ) operating leaver of air break switch 400 a ( xix ) connector of air break switch 400 a ( xx ) arching horn of air break switch 400 a ( xxi ) jaw of air break switch 200a ( xxii ) blade of of air break switch 200a ( xxiii ) post insulator of air break switch 200a ( xxiv ) bearing of air break switch 200a ( xxv ) phase coupling pipe of air break switch 200 a ( xxvi ) down pipe of air break switch 200 a ( xxvii ) operating handle of air break switch 200 a ( xxviii ) operating leaver of air break switch 200 a ( xxix ) connector of air break switch 200 a ( xxx ) arching horn of air break switch 200 a vcb repairing item ( i ) trip coil of 33kv vcb ( ii ) trip coil of 11kv vcb ( iii ) closing coil of 33kv vcb ( iv ) closing coil of 11kv vcb ( v ) push button switch 5a ( vi ) test terminal block 5a ( vii ) 33 kv indoor current transformers of ratio as required suitable for metering and protection. ( viii ) 33 kv outdoor current transformers of ratio as required suitable for metering and protection. ( ix ) 11 kv indoor current transformers of ratio as required suitable for metering and protection. ( x ) 11 kv outdoor current transformers of ratio as required suitable for metering and protection. ( xi ) 33000 / 110 volts single phase voltage transformer indoor. ( xii ) 33000 / 110 volts single phase voltage transformer outdoor. ( xiii ) 11000 / 110 volts single phase voltage transformer indoor. ( xiv ) 11000 / 110 volts single phase voltage transformer outdoor. ( xv ) flush type switchboard mounting pattern 96x96 sq.mm m.i. voltmeter ( xvi ) voltmeter phase selector switch. ( xvii ) indicating lamps coloured red, amber and blue, white, green, etc. ( xviii ) auxiliary switch having minimum of 8 contacts, 4 normally open and 4 normally closed ( xix ) flush mounting pattern 96x96 sq.mm m.i. ammeter ( xx ) ammeter selector switch to indicate phase current ( xxi ) over current and earth fault numerical relay ( xxii ) automatic door illuminating lamps with switch ( xxiii ) 240 v, 100 w, ac single phase anti / condensation heaters, with thermostat ( 0 60 deg. c ) and switch. ( xxiv ) operation counter for vcb ( xxv ) bus bar spout epoxy casted r phase of 33kv indoor vcb ( xxvi ) bus bar spout epoxy casted y phase of 33kv indoor vcb ( xxvii ) bus bar spout epoxy casted b phase of 33kv indoor vcb ( xxviii ) circuit spout epoxy casted of 33kv indoor vcb ( xxix ) housing for vacuum interrupter of 33kv indoor vcb ( xxx ) drive insulator 33kv vcb ( xxxi ) release coil of 33kv indoor vcb ( xxxii ) bus bar spout epoxy casted r phase of 11kv indoor vcb ( xxxiii ) bus bar spout epoxy casted y phase of 11kv indoor vcb ( xxxiv ) bus bar spout epoxy casted b phase of 11kv indoor vcb ( xxxv ) circuit spout epoxy casted of 11kv indoor vcb ( xxxvi ) housing for vacuum interrupter of 11kv indoor vcb ( xxxvii ) drive insulator of 11kv vcb ( xxxviii ) release coil of 11kv indoor vcb ( xxxix ) vacuum interrupter of 33kv outdoor type ( xl ) vacuum interrupter of 33kv indoor type ( xli ) vacuum interrupter of 11kv outdoor type ( xlii ) vacuum interrupter of 11kv indoor type ( xliii ) buzzer / hooter ( xliv ) t n c switch mrt related items ( i ) fully automatic energy meter test bench with 0.02 class, 10 position, for testing of 1 ph & 3 ph energy meters with 5 years maintenance, accreditation from nabl and software updation. ( ii ) instrument transformer ( ct pt ) test system ( iii ) transformer turn ratio meter and measurement test kit ( iv ) transformer oil filtering machine 500 gph ( v ) circuit breaker operational analyzer ( vi ) 3 ph relay test kit with all necessary accessories ( vii ) primary injection kit 1000 a with relay testing facility ( viii ) ht coil winding machine its installation, testing & commissioning ( ix ) lt coil winding machine its installation, testing & commissioning ( x ) 03 ( three ) phase transformer winding resistance meter ( xi ) digital multimeter, 750v ( xii ) capacitance tan delta test set for transformer, motor and switchgear ( xiii ) capacitance tan delta test set for cables ( xiv ) vaccum interrupter tester ( xv ) secondary injection kit ( xvi ) digital ht earth tester ( xvii ) 3 ph power quality analyser ( xviii ) 05 kv insulation tester ( manual ) ( xix ) 10 kv insulation tester ( motarized ) ( xx ) digital clamp meter; 20 1000a, 200 v dc ( xxi ) digital clamp meter; 20a ( 1ma 20a ) ( xxii ) discharge rod ( make fibre ) ( xxiii ) thermal imaging camera ( xxiv ) single phase & three phase meter automatic testing bench for 20 positions ( 0.02s class rsm ) frp fencing ( i ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 63 / 100 / 200 / 500 kva substation etc...

Department Of Heavy Industry - Jharkhand

31723822 bids are invited for 400kv, 50ka for 1s, 3150a, cb connector suitable for al tube 4 inch ips, expansion type , 400kv, 50ka for 1s, 3150a, isolator hcb connector suitable for al tube 4 inch ips, rigid type , 400kv, 50ka for 1s, 2000a, isolator hcb connector suitable for twin moose , 400kv, 50ka for 1s, 3150a, ct connector suitable for al tube 4 inch ips, rigid type , 400kv, 50ka for 1s, 3150a, ct connector suitable for al tube 4 inch ips, expansion type , 400kv, 50ka for 1s, cvt connector suitable for twin moose , 400kv, 50ka for 1s, la connector suitable for twin moose , 400kv, 50ka for 1s, 3150a, bpi connector suitable for al tube 4 inch ips, sliding through type , 400kv, 50ka for 1s, bpi connector suitable for al tube 4 inch ips, rigid through type , 400kv, 50ka for 1s, bpi connector suitable for twin moose horizontal approach , 400kv, 50ka for 1s, 3150a, bpi connector suitable for al tube 4 inch ips, rigid and expansion type with tube break , 400kv, 50ka for 1s, 2000a, bushing connector suitable for twin moose , 400kv corona bell suitable for 4 inch ips al tube , 400kv, 50ka for 1s, 1000a, tee connector suitable for single moose to single moose , 400kv, 50ka for 1s, 1000a, tee connector suitable for twin moose to single moose , 400kv 50ka for 1s 2000a tee connector suitable for al tube 4 inch ips to twin conductor as per ts , 400kv, flexible spacer suitable for twin moose , 400kv, rigid spacer suitable for twin moose , 400kv, welding sleeve suitable for 4 inch ips al tube , 220kv, 40ka for 1s, 1600a, cb connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for twin moose , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, rigid type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, expansion rigid type with tube break , 220kv, 40ka for 1s, 1600a, isolator hcb connector suitable for al tube 4 inch ips, rigid rigid type with tube break , 220kv, 40ka for 1s, 2000a, ct connector suitable for al tube 4 inch ips, expansion type , 220kv, 40ka for 1s, 2000a, ct connector suitable for twin moose , 220kv, 40ka for 1s, cvt connector suitable for single moose , 220kv, 40ka for 1s, la connector suitable for twin moose , 220kv, 40ka for 1s, bpi connector suitable for al tube 4 inch ips, sliding through type , 220kv, 40ka for 1s, 1600a, bpi connector suitable for al tube 4 inch ips, rigid and expansion type with tube break , 220kv, 40ka for 1s, 1600a, bpi 90 degree connector suitable for al tube 4.5 inch ips, expansion expansion type with tube break , 220kv, 40ka for 1s, 1600a, bushing connector suitable for twin moose , 220kv corona bell suitable for 4 inch ips al tube , 220kv, 40ka for 1s, 1000a, tee connector suitable for single moose to single moose , 220kv, 40ka for 1s, 1000a, tee connector suitable for twin moose to single moose , 220kv, 40ka for 1s, 2000a, tee connector suitable for al tube 4 inch ips to twin conductor as per ts , 220kv, 40ka for 1s, flexible spacer suitable for twin moose , 220kv, 40ka for 1s, rigid spacer suitable for twin moose , 220kv, welding sleeve suitable for 4 inch ips al tube , strain tension clamps bolted type for earthwire with d shackle assembly , clamps and connectors pg clamp for shield wires of dia 10.98mm , cleat type clamps for earthing down conductor 10.98mm dia , cleat type clamps for 75 x 12mm g.s. flat for equipment structure , pad type clamp for connecting 10.98mm dia. g.i. wire on one side and 75x12mm gs strips on other side...

Jharkhand State Electricity Board - Jharkhand

30833266 247 / pr / jbvnl / 2021 22 for supply of electric line materials , electrical items : , 33 kv d.p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] , 11 kv d.p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] , ms channel ( 100x50x6 mm ) for 11 kv ab switch [ galvanized ] , ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ galvanized ] , 11kv top channel ( 100x50x6 ) 9.56 kg per meter [ galvanized ] , ms angle for l t distribution bus ( 35 x 35 x6 mm ) [ galvanized ] , transformer base channel ( 100x50x6 mm ) [ galvanized ] , transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ galvanized ] , 33 kv v cross arm ( 100x 50x 6 mm ) [ galvanized ] , 11 kv v cross arm ( 75x 40x 6 mm ) [ galvanized ] , stay set complete ( 1900x20 mm ) with staywire 7 / 10 swg 8 kgs & guy insulator ) , lt stay set complete ( 1700x16mm ) with stay wire 7 / 12 swg , stay set complete ( 1700x16 mm ) with stay wire 7 / 10 swg 8kgs & guy insulator , stay set complete for dss with wire , 33 kv pole top bracket for 60kg rail pole [ galvanized ] , 11kv pole top bracket 50x8 mm flat [ galvanized ] , 33 kv angle stay clamp ( 50x6 mm ) [ galvanized ] , 11 kv angle stay clamp ( 50 x 10 mm ) [ galvanized ] , angle / sidestay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] , support clamp for v cross arm for 60kg rail pole [ galvanized ] , support clamp for 11 kv v cross arm [ galvanized ] , 33 kv d.p channel support clamp ( 50x6 mm ) [ galvanized ] , clamp ( 50 x 6 mm flat ) for top channel [ galvanized ] , clamp ( 50 x 6 mm ) for ab switch base channel [ galvanized ] , clamp ( 50 x 6 mm ) for transformer base channel [ galvanized ] , clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] , clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] , 33 kv back clamp for top bracket [ galvanized ] , back clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] , back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ galvanized ] , alluminium binding wire , ms base plate for 33 kv , anti climbing device ( barbed wire ) , 33 kv back clamp for line dp channel [ galvanized ] , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , danger board 33kv , 11 kv back clamp for top bracket [ galvanized ] , 11 kv back clamp for v cross arm [ galvanized ] , gi wire no. 10 for earthing , gi stya wire no. 7 / 10 , gi wire no. 8 for earthing , gi wire no. 7 / 8 , 11 kv back clamp for line dp channel [ galvanized ] , 11 kv d.p channel support clamp ( 50x6 mm ) [ galvanized ] , gi stay wire no. 7 / 10, 7 / 12, 7 / 14, 7 / 16 , gi wire no. 8 , m s nuts & bolts of different size , aluminium tape , ms flat ( 75x40x6 mm ) [ galvanized ] , danger board 11kv , note:gst must be define / mentioned otherwise price part not be considered....

Jharkhand State Electricity Board - Jharkhand

30819752 supply of electric line materials , electrical items : , fuse wire 12 swg , fuse wire 14 swg , fuse wire 16 swg , fuse wire 18 swg , fuse wire 22 swg , fuse wire 28 swg , fuse wire 32 swg , all types of connectors , connector pipe to panther , connector panther to panther , connector pipe to ab switch , connector panther to ab switch , connector dog to ab switch , g.i. wire no. 6 , g.i. wire no. 8 , g.i. wire no. 10 for earthing , g.i. wire no. 7 / 16 , earthing g.i strip for ( 65x6 ) , stay set complete ( 1900*20 mm ) with stay wire 7 / 10 swg 8 kg. & guy insulator , stay set complete ( 1800 x16 mm ) with stay wire 7 / 10 swg 8 kgs & guy insulator , lt stay set complete ( 1700 x16 mm ) with stay wire 7 / 12 swg , stay set complete for dss with wire , ms nuts & bolts different size , al. winding wire , earth clamp for earthwire ( 50x6mm ) galvanised , gi earthing pipe 3.1 meter long ( 40mm dia ) , 33 kv angle stay clamp ( 50x6mm ) galvanized , angle / side stay clamp ( 50x6mm ) for 8 mtr 200kg psc pole , ms base plate for 33 kv , anticlimbing device ( barbed wire ) , danger board 33kv , buckle for strap , spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and outgoing 3 phase connection as per field requirement , fabrication item galvanised ( different types of 33kv / 11 kv line ) , note:gst must be define / mentioned otherwise price part not be considered....

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

30791920 supply of 1 fuse wire 12 swg 2 fuse wire 14 swg 3 fuse wire 16 swg 4 fuse wire 18 swg 5 fuse wire 22 swg 6 fuse wire 28 swg 7 fuse wire 32 swg 8 all types of connectors 9 connector pipe to panther 10 connector panther to panther 11 connector pipe to ab switch 12 connector panther to ab switch 13 connector dog to ab switch 14 g.i. wire no. 6 15 g.i. wire no. 8 16 g.i. wire no. 10 for earthing 17 g.i. wire no. 7/16 18 earthing g.i strip for (65x6) 19 stay set complete (1900*20 mm) with stay wire 7/10 swg 8 kg. & guy insulator 20 stay set complete (1800 x16 mm) with stay wire 7/10 swg 8 kgs & guy insulator 21 lt stay set complete (1700 x16 mm) with stay wire 7/12 swg 22 stay set complete for dss with wire 23 ms nuts & bolts different size 24 al. winding wire 25 earth clamp for earthwire(50x6mm) galvanised 26 gi earthing pipe 3.1 meter long (40mm dia) 27 33 kv angle stay clamp(50x6mm) galvanized 28 angle/side stay clamp(50x6mm) for 8 mtr 200kg psc pole 29 ms base plate for 33 kv 30 anticlimbing device( barbed wire) 31 danger board 33kv 32 buckle for strap 33 spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement 34 fabrication item galvanised (different types of 33kv/11 kv line) ...

Jharkhand State Electricity Board - Jharkhand

30772977 nit 255 / pr / jbvnl / 21 22 procurement of electric line materials under adp head for fy 2021 22 under electric supply area jamshedpur , electrical items : , gi wire no. 8 , gi stay wire no. 7 / 8 , gi wire no. 10 for earthing , gi stay wire no. 7 / 10 , gi stay wire no. 7 / 12, , gi stay wire no.7 / 14, , gi stay wire no. 7 / 16 , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , gi wire no. 8 for earthing , aluminium binding wire , anticlimbing device ( barbed wire ) ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

30075798 supply of materials 1 33 kv disc insulator (polymer type) 90 kn with h/w fitting 2 33 kv pin insulator(polymer) with pin 3 11 kv pin insulator (polymer) with pin 4 11 kv disc insulator (polymer type) 70 kn with h/w 5 11 kv disc insulator polymer 45 kn with h/w fitting 6 11 kv h.g. fuse set 7 11 kv lightening arrestor s/stn.type 9kv 10ka heavy duty 8 33 kv h.g. fuse set 9 33 kv post insulator 1 connector pipe to panther 2 connector panther to panther 3 connector panther to ab switch 4 connector pipe to ab switch 5 connector dog to ab switch 6 aluminium binding wire 7 jointing sleeve for panther/wolf 8 jointing sleeve for rabbit 9 p g clamp for 150 sq mm conductor (wolf) 10 p g clamp for 100 sq.mm 11 p g clamp for 70 sq mm conductor 1 gi earthing pipe 3.1 meter long (40 mm dia) 2 earthing complete (conventional) for power transformer 3 earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long 4 earth clamp for earthwire (50 x 6 mm)[galvanized] 5 earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) 6 gi wire 6 swg 7 gi wire 8 swg 8 gi wire no. 10 for earthing 1 stay set complete (1900x20 mm) with staywire 7/10 swg 8 kgs & guy insulator) 2 stay set complete (1800x16 mm) with staywire 7/10 swg 8 kgs & guy insulator) 3 stay set complete for dss with wire 4 lt stay set complete (1700x16 mm) with stay wire 7/12 swg 5 33 kv angle stay clamp (50 x 6 mm) [galvanized] 6 angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized] 7 m s nuts & bolts of different size 1 33 kv straight through jointing kit 400 mm2 2 33 kv straight through jointing kit 300 mm2 3 11 kv straight through jointing kit 240 mm2 4 termination kit for 400 mm2 (33 kv) 5 termination kit for 240/300 mm2 (11 kv) 1 suspension clamp suitable for 35 95 sqmm bare messenger (including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle) 2 dead end clamp suitable for 70 95 sqmm bare messenger (including 1 no. dead end bracket + 1 no. dead end + 1.5 mtr ss strap + 2 nos. ss buckle) 3 spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement 4 pre insulated mid span joint suitable 95 mm2 phases 5 insulation piercing connector for db charging 6 insulation piercing connector branching suitable for t joints ...

Jharkhand State Electricity Board - Jharkhand

30056791 supply of materials under o and m head , electrical items : , gi earthing pipe 3.1 meter long ( 40 mm dia ) , earthing complete ( conventional ) for power transformer , earthing ( chemical ) with gi earthing pipe 20 mm 2.5 mtrs. long , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , earthing ( chemical ) with gi earthing pipe 40 mm 3.1 mtrs. long ( bentonite as intermittent layers ) , gi wire 6 swg , gi wire 8 swg , gi wire no. 10 for earthing...

Jharkhand State Electricity Board - Jharkhand

30002175 177 / pr / jbvnl / 2021 22 supply of electrical line materials under adp and om head for fy 21 22 , electrical items : , ms nuts & bolts 3 ( f.th. ) ( galvanized ) , ms nuts & bolts 4 ( f.th. ) ( galvanized ) , ms nuts & bolts 8 ( f.th. ) ( galvanized ) , ms nuts & bolts 10 ( f.th. ) ( galvanized ) , pg clamp for 100 sq. mm conductor , pg clamp for 100 sq. mm , pg clamp for 150 sq. mm conductor , pg clamp for 150 sq. mm conductor ( wolf ) , pg clamp for 80 sq. mm , pg clamp for 70 sq. mm conductor , angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] , earth clamp for earthwire ( 50x6 mm ) [ galvanized ] , packing piece for rail pole [ 0.800 kg. per set ] , back clamp ( 50x6 ) jointing / packing piece for 60 kg. rail pole [ galvanized ] , 33 kv pole top bracket for 60 kg. rail pole [ galvanized ] ( 2.90 kg. per no. ) , back clamp for 33 kv v cross arm & top bracket [ galvanized ] ( 1.79 kg. per no. ) , 33 kv stay clamp side / angle ( 50 x 6 mm ) [ galvanized ] [ 1.75 kg. per pair ] , 33 kv cross bracing for dp channel [ galvanized ] [ 42.00 kg. per set ] , 33 kv clamp for cross bracing [ galvanized ] [ 1.10 kg. per no ] , 11 kv clamp for cross bracing [ 3.580 kg. per set ] , 11 kv side stay clamp ( 50 x 6 mm ) [ 2.400 kg. per no. ] , 33 kv back clamp for top brackt [ galvanized ] , back clamp ( 50x6 ) for 60 kg. rail pole [ galvanized ] , 33 kv back clamp for line d.p channel [ galvanized ] , 33 kv dp channel support clamp ( 50x6 ) [ galvanized ] [ 1.40 kg. per no. ] , 11 kv dp channel support clamp ( 50x6 ) [ galvanized ] , 11 kv pole top bracket [ galvanized ] [ 2.100 kg. per no. ] , 11 kv pole top bracket ( 50x8 ) mm flat [ galvanized ] , 11 kv back clamp for top bracket [ galvanized ] [ 1.30 kg. per no. ] , support clamp for v cross arm for 60 kg. rail pole [ galvanized ] , 11 kv back clamp for v cross arm [ galvanized ] [ 1.30 kg. per no. ] , support clamp for 11 kv v cross arm [ galvanized ] , 11 kv angle stay clamp ( 50 x 6 mm ) [ galvanized ] [ 2.80 kg. per pair ] , 11 kv back clamp for line d.p channel [ galvanized ] , clamp ( 50x6 mm ) for transformer base channel [ galvanized ] [ 1.080 kg. per no. ] , clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] [ 1.220 kg. per no. ] , clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] [ 1.120 kg. per no. ] , clamp ( 50 x 6 mm ) for ab switch base channel [ galvanized ] [ 0.875 kg. per no. ] , clamp ( 50 x 6 mm flat ) for transformer top channel [ galvanized ] , 33 kv angle stay clamp ( 50 x 6 mm ) [ galvanized ] , ms flat ( 40 x 6 mm & 6 mtrs. long ) [ galvanized ] ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

28288913 supply of following materials 1 33 kv pin insulator(polymer) with pin including support for jumper 2 33 kv disc. insulator(polymer) 70 kn with h/w 3 11 kv pin insulator (polymer) with pin including support for jumper 4 11 kv disc insulator polymer 45 kn with h/w fitting 5 11 kv lightening arrestor s/stn.type 9kv 10ka heavy duty 6 33 kv lightening arrestor s/stn.30kv 10ka ( class ii) heavy duty 1 earthing complete (conventional) for power transformer 2 earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) 3 11 kv earthing (chemical) with earthing pipe 20 mm 1.2 mtrs. long 4 aluminium pipe 40 mm dia 5 aluminium pipe connector 6 earthingg.i.strip for (65x6) 7 gi wire no. 8 for earthing 8 earth clamp for earthwire (50 x 6 mm) [galvanized] 9 gi wire no. 10 for earthing 10 gi wire no. 8 11 m s nuts & bolts of different size 1 stay set complete (1900x20 mm) with staywire 7/10 swg 8 kgs& guy insulator) 2 lt stay set complete (1700x16 mm) with stay wire 7/12 swg 3 stay set complete for dss with wire 1 11 kv 3 core heat shrinkable indoor cable jointing kit 240 300 mm2 2 11 kv 3 core heat shrinkableoutdoor cable jointing kit 240 300 mm2 3 11 kv 3 core heat shrinkableoutdoor cable jointing kit 95 300 mm2 4 11 kv 3 core heat shrinkable indoor cable jointing kit 95 300 mm2 5 11 kv 3 core heat shrinkable straight through cable jointing kit 300 mm2 6 11 kv 3 core heat shrinkable indoor cable jointing/termination kit 300 mm2 7 11 kv 3 core heat shrinkable outdoor cable jointing/termination kit 300 mm2 8 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 9 33 kv 3 core heat shrikable indoor cable termination kit for 400mm2 10 33 kv 3 core heat shrinkable out door type cable termination kit for 400mm2 1 2.5 mm2 copper 2 core control cable (armoured) 2 2.5 mm2 copper 4 core control cable (armoured) 3 2.5 mm2 copper 6 core control cable (armoured) 4 2.5 mm2 copper 12 core control cable (armoured) 1 structure for 33kv lightening arrestor [galvanized] 2 gantry column, girder structures for 33/11 kv pss for single transformer [galvanized] 3 a structures for top mounted ab switch on 11 kv & 33 kv bus [galvanized] 4 a structures for 11 kv take off with top mounted ab switch and provision of lightening arrester [galvanized] 5 structure for 33 & 11 kv isolator [galvanized] 6 structure for post insulator for 33kv [galvanized] 7 33 kv pole top bracket for 60kg rail pole [galvanized] 8 33 kv back clamp for top bracket [galvanized] 9 33 kv v cross arm (100x 50x 6 mm) [galvanized] 10 back clamp ( 50x6 mm) for 60kg rail pole[galvanized] 11 support clamp for v cross arm for 60kg rail pole[galvanized] 12 back clamp (50x6 mm)jointing/ packing piece for 60kg rail pole [galvanized] 13 p g clamp for 150 sq mm conductor 14 33 kv back clamp for line dp channel [galvanized] 15 33 kv d.p channel support clamp (50x6 mm) [galvanized] 16 33 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized] 17 danger board 33kv 1 11kv pole top bracket 50x8 mm flat [galvanized] 2 11 kv back clamp for top bracket [galvanized] 3 11 kv v cross arm (75x 40x 6 mm) [galvanized] 4 11 kv back clamp for v cross arm [galvanized] 5 support clamp for 11 kv v cross arm [galvanized] 6 p g clamp for 100 sq mm conductor 7 11 kv back clamp for line dp channel [galvanized] 8 11 kv d.p channel support clamp (50x6 mm) [galvanized] 9 11 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized] 10 angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized] 11 clamp (50 x 6 mm flat) for top channel [galvanized] 12 clamp (50 x 6 mm) for ab switch base channel [galvanized] 13 11 kv angle stay clamp (50 x 10 mm) [galvanized] 14 ms channel (100x50x6 mm) for 11 kv ab switch [galvanized] 15 ms angle for l t distribution bus (35 x 35 x6 mm) [galvanized] 16 clamp (50 x 6 mm) for transformer base channel [galvanized] 17 clamp (50 x 6 mm) for transformer belting [ galvanized] 18 clamp (50 x 6 mm) for lt bus & h.g fuse set [ galvanized] 19 ms flat (75x40x6 mm)[ galvanized] 20 danger board 11kv ...

Jharkhand State Electricity Board - Jharkhand

28280978 procurement of earthing complete , aluminium pipe connector , g . i wire , electrical items : , earthing complete ( conventional ) for power transformer , earthing ( chemical ) with gi earthing pipe 40 mm 3 . 1 mtrs . long ( bentonite as intermittent layers ) , 11 kv earthing ( chemical ) with earthing pipe 20 mm 1 . 2 mtrs . long , aluminium pipe 40 mm dia , aluminium pipe connector , earthing g . i . strip for ( 65x6 ) , gi wire no . 8 for earthing , earth clamp for earthwire ( 50 x 6 mm ) [galvanized] , gi wire no . 10 for earthing , gi wire no . 8 , m s nuts & bolts of different size...

Jharkhand State Electricity Board - Jharkhand

28016443 nit 28/pr/jbvnl/21 22 procurement of electrical line materials under adp head for fy 2020 21 under electric supply area , jamshedpur , electrical items : , gi wire no . 8 for earthing , gi wire no . 8 , gi wire no . 10 for earthing , pg clamp for 100 sq mm conductor ) , pg clamp for 150 sq mm conductor ) , ms flat ( 75x40x6 mm ) , earth clamp for earthwire ( 50 x 6 mm ) , male female contact of 11 kv ab switch 600 amp ) , aluminium pipe 40 mm dia , aluminium pipe connector...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

27974033 supply of electric line materials , 1 gi wire no. 8 for earthing 2 gi wire no. 8 3 gi wire no. 10 for earthing 4 pg clamp for 100 sq mm conductor) 5 pg clamp for 150 sq mm conductor) 6 ms flat (75x40x6 mm) 7 earth clamp for earthwire (50 x 6 mm) 8 male female contact of 11 kv ab switch 600 amp) 9 aluminium pipe 40 mm dia 10 aluminium pipe connector...

Jharkhand State Electricity Board - Jharkhand

27376155 supply of electric line materials under adp head fy 2020 21 , electrical items : , 33 kv pole top bracket for 60kg rail pole [galvanized] , 33 kv back clamp for top bracket [galvanized] , 33 kv v cross arm ( 100x 50x 6 mm ) [galvanized] , back clamp ( 50x6 mm ) for 60kg rail pole[galvanized] , support clamp for v cross arm for 60kg rail pole[galvanized] , back clamp ( 50x6 mm ) jointing/ packing piece for 60kg rail pole [galvanized] , gi wire no . 8 for earthing , 33 kv back clamp for line dp channel [galvanized] , 33 kv d . p channel support clamp ( 50x6 mm ) [galvanized] , 33 kv d . p channel ( 100x50x6 mm ) 1 . 3 meter long [galvanized] , earth clamp for earthwire ( 50 x 6 mm ) [galvanized] , 11kv pole top bracket 50x8 mm flat [galvanized] , 11 kv back clamp for top bracket [galvanized] , 11 kv v cross arm ( 75x 40x 6 mm ) [galvanized] , 11 kv back clamp for v cross arm [galvanized] , support clamp for 11 kv v cross arm [galvanized] , gi wire no . 10 for earthing , 11 kv back clamp for line dp channel [galvanized] , 11 kv d . p channel support clamp ( 50x6 mm ) [galvanized] , 11 kv d . p channel ( 100x50x6 mm ) 1 . 3 meter long [galvanized] , angle/side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole[galvanized] , clamp ( 50 x 6 mm flat ) for top channel [galvanized] , clamp ( 50 x 6 mm ) for ab switch base channel [galvanized] , 11 kv angle stay clamp ( 50 x 10 mm ) [galvanized] , ms channel ( 100x50x6 mm ) for 11 kv ab switch [galvanized] , 11kv top channel ( 100x50x6 ) 9 . 56 kg per meter [galvanized] , ms angle for l t distribution bus ( 35 x 35 x6 mm ) [galvanized] , transformer base channel ( 100x50x6 mm ) [galvanized] , ms channel ( 75x40x6 mm ) for supporting h . g fuse & l . a [galvanized] , transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [galvanized] , clamp ( 50 x 6 mm ) for transformer base channel [galvanized] , clamp ( 50 x 6 mm ) for transformer belting [ galvanized] , clamp ( 50 x 6 mm ) for lt bus & h . g fuse set [ galvanized] , gi wire no . 8 , ms flat ( 75x40x6 mm ) [ galvanized] , ht al . studs 5/8x17 1/2 , ht bushing clamp 4 hole , ht al . studs 5/8x17 1/2 , ht bushing clamp 4 hole , ht al . studs 5/8x17 1/2 , ht bushing clamp 4 hole , ht al . studs 5/8x17 1/2 , ht bushing clamp 4 hole , ht al . studs 5/8x17 1/2 , ht al . studs 5/8x17 1/2 , ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

27365492 supply of 33 kv lightening arrestor s/stn.30kv 10ka ( class ii) heavy duty 11 kv lightening arrestor s/stn.type 9kv 10ka heavy duty danger board 33kv p g clamp for 150 sq mm conductor p g clamp for 100 sq mm conductor danger board 11kv male female contact of 11 kv ab switch 600 amp al paint red oxide paint 33 kv pin insulator(polymer) with pin including support for jumper, 33 kv disc. insulator(polymer) 70 kn with h/w, 11 kv pin insulator (polymer) with pin including support for jumper, 11 kv disc insulator polymer 45 kn with h/w fitting, earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers), 11 kv earthing (chemical) with earthing pipe 20 mm 1.2 mtrs. long, 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2, 33 kv 3 core heat shrikable indoor cable termination kit for 400mm2, 33 kv 3 core heat shrinkable out door type cable termination kit for 400mm2, 11 kv 3 core heat shrinkable straight through cable jointing kit 300 mm2, 11 kv 3 core heat shrinkable indoor cable jointing/termination kit 300 mm2, 11 kv 3 core heat shrinkable outdoor cable jointing/termination kit 300 mm2, hdpe pipe 160mm /6 pe 63 grade, stay set complete (1900x20 mm) with staywire 7/10 swg 8 kgs & guy insulator) lt stay set complete (1700x16 mm) with stay wire 7/12 swg stay set complete for dss with wire, pre insulated mid span joint suitable 95 mm2 phases spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement service main anchor clamp for proper support of service cable(4mm2 and 10 mm2) route & joint indicating, m s nuts & bolts of different size 33 kv pole top bracket for 60kg rail pole [galvanized] (unit wt. 2.9 kg.) 33 kv back clamp for top bracket [galvanized] (unit wt. 1.79 kg.) 33 kv v cross arm (100x 50x 6 mm) [galvanized] (unit wt. 20.44 kg.) back clamp ( 50x6 mm) for 60kg rail pole[galvanized] (unit wt. 1.79 kg.) support clamp for v cross arm for 60kg rail pole[galvanized] (unit wt. 1.79 kg.) back clamp (50x6 mm)jointing/ packing piece for 60kg rail pole [galvanized] (unit wt. 1.79 kg.) gi wire no. 8 for earthing 33 kv back clamp for line dp channel [galvanized] (unit wt. 1.79 kg.) 33 kv d.p channel support clamp (50x6 mm) [galvanized] (unit wt. 1.79 kg.) 33 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized] (unit wt. 53.00 kg.) earth clamp for earthwire (50 x 6 mm) [galvanized] (unit wt. 1.5 kg.) 11kv pole top bracket 50x8 mm flat [galvanized] (unit wt. 2.1 kg.) 11 kv back clamp for top bracket [galvanized] (unit wt. 1.00 kg.) 11 kv v cross arm (75x 40x 6 mm) [galvanized] (unit wt. 10.93 kg.) 11 kv back clamp for v cross arm [galvanized] (unit wt. 1.00 kg.) support clamp for 11 kv v cross arm [galvanized] (unit wt. 1.00 kg.) gi wire no. 10 for earthing 11 kv back clamp for line dp channel [galvanized] (unit wt. 2.24 kg.) 11 kv d.p channel support clamp (50x6 mm) [galvanized] (unit wt. 2.24 kg.) 11 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized] (unit wt. 32.00 kg.), angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized] (unit wt. 1.79 kg.) clamp (50 x 6 mm flat) for top channel [galvanized] (unit wt. 2.16 kg.) clamp (50 x 6 mm) for ab switch base channel [galvanized] (unit wt. 4.32 kg.) 11 kv angle stay clamp (50 x 10 mm) [galvanized] (unit wt. 1.9 kg.) ms channel (100x50x6 mm) for 11 kv ab switch [galvanized] (unit wt. 53.44 kg.) 11kv top channel (100x50x6) 9.56 kg per meter [galvanized] (unit wt. 53.44 kg.) ms angle for l t distribution bus (35 x 35 x6 mm) [galvanized] (unit wt. 18.00 kg.) transformer base channel (100x50x6 mm) [galvanized] (unit wt. 53.44 kg.) ms channel (75x40x6 mm)for supporting h.g fuse & l.a [galvanized] (unit wt. 49.83 kg.) transformer belting (50x50x6 mm) & belting support (40x40x6 mm)[galvanized] (unit wt. 30.86 kg.) clamp (50 x 6 mm) for transformer base channel [galvanized] (unit wt. 4.32 kg.) clamp (50 x 6 mm) for transformer belting [ galvanized] (unit wt. 2.16 kg.) clamp (50 x 6 mm) for lt bus & h.g fuse set [ galvanized] (unit wt. 2.5 kg.) gi wire no. 8 ms flat (75x40x6 mm)[ galvanized] (unit wt. 2.40 kg.), 11 kv d.o. fuse unit. ...

Jharkhand State Electricity Board - Jharkhand

27353712 247/pr/jbvnl/2020 21 supply of electrical line materials under adp head for fy 20 21 , electrical items : , ms nuts & bolts 3 ( f . th . ) ( galvanized ) , ms nuts & bolts 4 ( f . th . ) ( galvanized ) , ms nuts & bolts 8 ( f . th . ) ( galvanized ) , ms nuts & bolts 10 ( f . th . ) ( galvanized ) , p g clamp for 100 sq . mm conductor , p g clamp for 150 sq . mm conductor , angle/side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [galvanized] , earth clamp for earthwire ( 50x6 mm ) [galvanized] , back clamp ( 50x6 ) jointing/ packing piece for 60 kg . rail pole [galvanized] , 33 kv pole top bracket for 60 kg . rail pole [galvanized] , 33 kv back clamp for top bracket [galvanized] , back clamp ( 50x6 ) for 60 kg . rail pole [galvanized] , 33 kv back clamp for line d . p channel [galvanized] , 33 kv dp channel support clamp ( 50x6 ) [galvanized] , 11 kv dp channel support clamp ( 50x6 ) [galvanized] , 11 kv pole top bracket ( 50x8 ) mm flat [galvanized] , 11 kv back clamp for top bracket [galvanized] , support clamp for v cross arm for 60 kg . rail pole [galvanized] , 11 kv back clamp for v cross arm [galvanized] , support clamp for 11 kv v cross arm [galvanized] , 11 kv angle stay clamp ( 50 x 6 mm ) [galvanized] , 11 kv back clamp for line d . p channel [galvanized] , clamp ( 50x6 mm ) for transformer base channel [galvanized] , clamp ( 50 x 6 mm ) for ab switch base channel [galvanized] , clamp ( 50 x 6 mm flat ) for transformer top channel [galvanized] , clamp ( 50 x 6 mm ) for lt bus & h . g fuse set [galvanized] , clamp ( 50 x 6 mm ) for transformer belting [galvanized] , ms flat ( 75x40x6 mm ) [galvanized]...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

27341202 supply of the relevant materials 33 kv lightening arrestor s/stn. (30 kv, 10 ka, class ii) heavy duty 33 kv pin insulator (polymer) with pin including support for jumper 33 kv disc insulator (polymer) 70 kn with h/w fitting pre insulated mid span joint suitable 95 mm2 phases spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement service main anchor clamp for proper support of service cable (4 mm2 and 10 mm2) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 33 kv 3 core heat shrinkable indore cable termination kit for 400 mm2 stay set complete (1900x20 mm) with staywire 7/10 swg 8 kgs & guy insulator) ms nuts & bolts 3 (f.th.) (galvanized) p g clamp for 100 sq. mm conductorp g clamp for 100 sq. mm conductor earth clamp for earthwire (50x6 mm) [galvanized] back clamp (50x6) jointing/ packing piece, 11 kv v cross arm (75x40x6 mm) [galvanized], 33 kv d.p channel (100x50x6 mm) 1.3 meter long [galvanized], m s channel (100x50x6 mm) for 11 kv ab switch [galvanized], 11 kv top channel (100x50x6 mm) 9.56 kg. per meter [galvanized], 11 kv top channel (100x50x6 mm) 9.56 kg. per meter [galvanized], 11 kv top channel (100x50x6 mm) 9.56 kg. per meter [galvanized], 11 kv top channel (100x50x6 mm) 9.56 kg. per meter [galvanized], 11 kv top channel (100x50x6 mm) 9.56 kg. per meter [galvanized], gi wire no. 8 for earthing, gi wire no. 8 for earthing, gi wire no. 8 for earthing, 11 kv earthing (chemical) with earthing pipe 20 mm 1.2 mtrs. long, 11 kv earthing (chemical) with earthing pipe 20 mm 1.2 mtrs. long, danger board 33kv, al. paint, raid oxide pain, 11 kv d.o. (drop out) fuse unit, 11 kv d.o. (drop out) fuse unit....

Jharkhand State Electricity Board - Jharkhand

27172402 supply of electrical line materials , ms base plate for 33 kv , 33 kv angle stay clamp ( 50 x 6 mm ) [ galvanized ] , ant climbing device ( barbed wire ) , danger board 33 kv , earth clamp for earthwire ( 50x6 mm ) [ galvanized ] , danger board 11 kv , earth clamp for earthwire ( 50x6 mm ) [ galvanized ] , gi earthing pipe 3 . 1 m long ( 40 mm dia ) , m s nuts & bolts of different size , angle / side stay clamp ( 50x6 mm ) for 8 mtr 200 kg pole psc pole ( galvanized ) ...

Jharkhand State Electricity Board - Jharkhand

27105678 supply of electric line materials under om head 20 21 1 gi wire no. 10 for earthing 2 gi earthing pipe 3.1 meter long ( 40 mm dia ) 3 earthing ( chemical ) with gi earthing pipe 40 mm 3.1 mtrs. long ( bentonite as intermittent layers ) 4 earthing ( chemical ) with gi earthing pipe 20 mm 2.5 mtrs. long 5 earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] 6 earthing g.i.strip for ( 65x6 ) ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

26986621 supply of 1 earthing complete (conventional) for power transformer nos. 11 2 earthingg.i.strip for (65x6) kg 200 3 earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) set 473 4 earth clamp for earthwire (50 x 6 mm) [galvanized] pair 2004 5 earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long set 698 6 gi earthing pipe 3.1 meter long (40 mm dia) set 300...

Jharkhand State Electricity Board - Jharkhand

26944173 procurement of earthing related materials , , earthing complete ( conventional ) for power transformer , earthing g . i . strip for ( 65x6 ) , earthing ( chemical ) with gi earthing pipe 40 mm 3 . 1 mtrs . long ( bentonite as intermittent layers ) , earthing ( chemical ) with gi earthing pipe 20 mm 2 . 5 mtrs . long , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] , gi earthing pipe 3 . 1 meter long ( 40 mm dia ) ...

Jharkhand State Electricity Board - Jharkhand

26851437 supply of electrical line materials under o and m head for fy 2020 21 , electrical items : , m s channel ( 100x50x6 mm ) for supporting transformer / 11 kv ab switch ( 53 . 440 kg per set ) , m s channel ( 75x40x6 mm ) for supporting h . g fuse & l . a ( 49 . 830 kg per set ) , clamp ( 50 x 6 mm ) for ab switch base channel ( 0 . 875 kg per no . ) , clamp ( 50 x 6 mm ) for transformer base channel ( 1 . 080 kg per no . ) , clamp ( 50 x 6 mm ) for h . g fuse set ( 1 . 120 kg per no . ) , transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) ( 26 . 500 kg per set ) , clamp ( 50 x 6 mm ) for transformer belting ( 1 . 220 kg per no . ) , angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] , earth clamp for earthwire ( 50x6 mm ) ( galvanized ) , m s angle for l t distribution bus ( 35 x 35 x6 mm ) ( 18 . 00 kg per set ) ...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

26398123 rate for materials works for transmission project and o and m work of jusnl m1761.1 tower strtcttre ht steel m1761.2 tower strtcttre ms steel m1761.3 stbstation strtcttre m1761.4 pipe type structure m1761.5 cable racks as per design requirement. m1761.6 galvanized ntts and bolts m1761.7 anti theft bolt m1761.8 gi fastners ( springing & falt washers ) m1762.1 earthing device pipe type m1762.2 earthing device counterpoise 120 metres m1762.3 earthing device counterpoise 280 metres m1762.4 danger board m1762.5 ntmber plate m1762.6 phase plate ( set of three ) m1762.7 circtit plate ( set of two ) m1762.8 anticlimbing device m1762.9 bird guard ( set of three ) m1763.1 acsr panther condtctor ( withott pv ) m1763.2 acsr zebra condtctor ( withott pv ) m1763.3 aaac zebra condtctor ( withott pv ) m1763.4 acsr moose condtctor m1763.5 aaac moose condtctor ( withott pv ) m1763.6 htls condutor capacity 240 mva, 1050 a ( equivalent to panther ) m1764 earthing & opgw cable m1764.1 7 / 3.15 g.i.earth wire m1764.2 opgw m1764.2.1 48 fibre opgw fibre optic cable ( dwsm ) m1764.2.2 24 fibre opgw fibre optic cable ( dwsm ) m1764.2.3 junction box ( 48 fibre ) m1764.2.4 junction box ( 24 fibre ) m1764.2.5 hardware set for opgw cable m1764.2.6 fodp 48f: indoor type, rack mounted with fcpc coupling and pig tails ( 5 mtrs each ) m1764.2.7 fibre optic approch cable, 24 fibre ( dwsm ) m1764.2.8 hardware set for above 24 fibre optic approch cable hardware fittings & accessories for different size of conductor and earth wire m1765.1.1 single suspension hard ware fitting suitable for aaac moose m1765.1.2 doubel suspension hardware fitting for aaac moose m1765.1.3 single tension hardware fitting for aaac moose m1765.1.4 doubel tension hardware fitting for aaac moose m1765.1.5 single suspension hard ware fitting for aaac moose m1765.1.6 doubel suspension hardware fitting for aaac moose m1765.1.7 single suspension hard ware fitting suitable for acsr moose m1765.1.8 single suspension pilot hard ware fitting suitable for acsr moose m1765.1.9 doubel suspension hardware fitting for acsr moose m1765.1.10 single tension hardware fitting for acsr moose m1765.1.11 doubel tension hardware fitting for acsr moose m1765.1.12 double i suspention 400kv qtad moose m1765.1.13 single i suspention pilot 400kv qtad moose m1765.1.14 qtad tension string 400kv qtad moose m1765.1.15 single suspension hard ware fitting suitable for aaac zebra m1765.1.16 doubel suspension hardware fitting for aaac zebra m1765.1.17 single tension hardware fitting for aaac moose m1765.1.18 doubel tension hardware fitting for aaac moose m1765.1.19 single suspension i hard ware fitting for acsr zebra ( 1x14, 90kn ) m1765.1.20 single suspension pilot hard ware fitting for acsr zebra ( 1x14, 90kn ) m1765.1.21 doubel suspension hardware fitting for acsr zebra ( 2x14, 90kn ) m1765.1.22 single tension hardware fitting for acsr zebra ( 1x15, 120kn ) m1765.1.23 double tension hardware fitting for acsr zebra ( 2x15, 120kn ) m1765.1.24 single suspension hard ware fitting for aaac panther m1765.1.25 double suspension hardware fitting for aaac panther m1765.1.26 double suspension hardware fitting for acsr panther m1765.1.27 single tension hardware fitting for acsr panther m1765.1.28 double tension hardware fitting for acsr panther m1765.1.29 single tension hardware fitting for aaac panther m1765.1.30 single suspension hard ware fitting for acsr panther m1765.1.31 single suspension pilot hard ware fitting for acsr panther m1765.1.32 single suspension i hard ware fitting for htls conductor ( 1050a ) w / o clamp m1765.1.33 single suspension pilot hard ware fitting for htls conductor ( 1050a ) w / o clamp m1765.1.34 double suspension hard ware fitting for htls conductor ( 1050a ) w / o clamp m1765.1.35 single tension hard ware fitting for htls conductor ( 1050a ) w / o clamp m1765.1.36 double tension hard ware fitting for htls conductor ( 1050a ) w / o clamp m1765.2.1 single suspension clamp for htls conductor ( 1050a ) m1765.2.2 double suspension clamp for htls conductor ( 1050a ) m1765.2.3 dead end tension clamp for htls conductor ( 1050a ) m1765.2.4 double tension clamp for htls conductor ( 1050a ) m1765.2.5 suspension clamp for 7 / 3.15 mm gs earthwire m1765.2.6 t clamp m1765.2.7 tension clamp for 7 / 3.15 mm gs earthwire m1765.3.1 terminal pad without holes m1765.3.2 terminal pad with holes m1765.4.1 pa rod ( complete set ) for acsr moose conductor m1765.4.2 pa rod for aaac zebra m1765.4.3 pa rod for acsr zebra m1765.4.4 pa rod for aaac panther m1765.4.5 pa rod for acsr panther m1765.5.1 bundle spacer for acsr moose conductor m1765.5.2 rigid spacer for acsr moose conductor m1765.6.1 vibration damper for htls conductor ( 1050a ) m1765.6.2 vibration damper for acsr moose conductor m1765.6.3 vibration damper for aaac zebra m1765.6.4 vibration damper for acsr zebra m1765.6.5 vibration damper for aaac panther m1765.6.6 vibration damper for acsr panther m1765.6.7 vibration damper for 7 / 3.15 mm gs earth wire m1765.6.8 vibration damper for aaac moose m1765.7.1 midspan compresion joint for htls conductor ( 1050a ) m1765.7.2 midspan compresion joint for acsr moose conductor m1765.7.3 midspan compresion joint for aaac zebra m1765.7.4 mid span compresion joint for acsr zebra m1765.7.5 midspan compresion joint for aaac panther m1765.7.6 midspan compresion joint for acsr panther m1765.7.7 midspan compresion joint for 7 / 3.15 mm gs earth wire m1765.8.1 repair sleeve for htls conductor ( 1050a ) m1765.8.2 repair sleeve for acsr moose conductor m1765.8.3 repair sleeve for aaac zebra m1765.8.4 repair sleeve for acsr zebra m1765.8.5 repair sleeve for aaac panther m1765.8.6 repair sleeve for acsr panther m1765.9.1 fexible earth bond for earth wire 7 / 3.15 mm gs earthwire insulators m1766.1.1 70 kn disc antifog insulator m1766.1.2 90 kn disc antifog insulator m1766.1.3 120 kn disc antifog insulator m1766.1.4 160 kn disc antifog insulator m1766.2.1 70 kn disc insulator m1766.2.2 90 kn disc insulator m1766.2.3 120 kn disc insulator m1766.2.4 160 kn disc insulator m1766.3.1 132kv long rod polymer insulator 70kn m1766.3.2 132kv long rod polymer insulator 90kn m1766.3.3 132kv long rod polymer insulator 120kn m1766.4.1 220kv long rod polymer insulator 90kn m1766.4.2 220kv long rod polymer insulator 120kn m1766.4.3 220kv long rod 160kn silicon composite insulator m1766.5.1 400kv long rod polymer insulator 120kn m1766.5.2 400kv long rod polymer insulator 160kn substation materials details m1767 circuit breaker with support structure, marshalling boxes, terminal connectors etc. ( current rating shall be equial to the current rating for which the short cuircuit test reports shall be furnished. ) ( spring spring ) m1767.1 400 kv cb ( sf6 ) m1767.2 220 kv cb ( sf6 ) m1767.3.1 132 kv cb ( sf6 ) 1600a m1767.3.2 132 kv cb ( sf6 ) 1250a m1767.5 33 kv cb ( vcb ) 1600 a m1768 isolator m1768.1.1 420kv horizontal central break, 3150a isolator with single earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1768.1.2 420kv horizontal central break, 2000a isolator with single earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1768.1.3 420kv horizontal central break, 2000a isolator with double earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1768.2.1 220kv, 1600 a, 40 ka with two earth switch ( double break isolator ) m1768.2.2 220kv, 1600 a, 40 ka with one earth switch ( double break isolator ) m1768.2.3 220 kv db isolator withott earth switch 1600amp. ( tandem arrangement ) m1768.2.4 220kv, 2500 a, 40 ka with two earth switch ( double break isolator ) m1768.2.5 220 kv 2500a db motorised isolator with earth switch m1768.2.6 220kv, 2500 a, 40ka without earth switch double breaker insulator ( high level beam mounted ) two nos of isolators shall be provided as sectionaliser of 220 kv main bus 1 m1768.3.1 132 kv single isolator withott earth switch 1600a, 31.5ka m1768.3.2 132 kv single isolator with earth switch 1600a m1768.3.3 132 kv 1250a db isolator with earth switch, 31.5ka m1768.3.4 132 kv 1250a dotble break isolator withott earth switch, 31.5ka m1768.3.5 132 kv 1600 hl beam motnted isolator withott earth switch m1768.3.6 132kv, 1600 a, 31.5 ka without earth switch ( double break high level beam mounted isolator ) m1768.3.7 132 kv 1250a db tandem isolator withott earth switch, 31.5ka m1768.4.1 33 kv single isolator withott earth switch m1768.4.2 33 kv dotble isolator with earth switch, 1250a 25ka m1768.4.3 33 kv dotble isolator withott earth switch, 1250a 25ka m1768.4.4 33 kv dotble isolator withott earth switch, 1250a 25ka ( tandem arrangement ) m1768.4.5 33kv 2500 a, 25 ka without earth switch ( double break high level beam mounted isolator ) m1769 current transformer 5 core ( 1 phase ) with marshaling boxes, terminal connectors class 0.2s m1769.1 400kv ct m1769.2 220 kv ct m1769.2.1 1600 800 400 200 / 1 1 1 1 1 a, 120% extended current rating, 40 ka, 0.2 class 5 core m1769.2.2 1600 800 400 200 / 1 1 1 1 1 a, 150% extended current rating, 40 ka, 0.2 class 5 core m1769.3 132 kv ct m1769.3.1 1200 600 300 150 / 1 1 1 1 1 a, 5 core 0.2 class , 31.5 ka with 120% extended current rating with marshalling boxes, terminal connectors etc. m1769.3.2 600 300 150 / 1 1 1 1 1 a, 5 core 0.2 class , 31.5 ka with 120% extended current rating with marshalling boxes, terminal connectors etc. m1769.4 33 kv ct m1769.4.1 600 300 150 / 1 a, 5 core 0.2 class 25 ka with 120% extended current rating with marshalling boxes terminal connectors m1769.4.2 1200 600 300 / 1a, 5 core 0.2 class 25 ka with 120% extended current rating with marshalling boxes terminal connectors m1769.4.3 33 kv nct m1770 surge arresters m1770.1 400kv sa m1770.2 220 kv la / sa m1770.3 132 kv la / sa m1770.4 33 kv la / sa m1771 1200a, horn gap fuse ( 1 phase ) m1772 capacitive voltage transformer m1772.1 400kv cvt m1772.2 220kv cvt, 4400pf cvts ( 1 phase ) for phase to phase coupling with all accessories, terminal connectors etc. m1772.3 132kv cvt, 8800pf cvts ( 1 phase ) with marshalling boxes, terminal connectors etc . m1773 portable discharge rod m1773.1 portable discharge rods for 220kv m1773.2 portable discharge rods ( 1 phase ) for 132kv m1773.3 portable discharge rods for 33kv m1774 supply hardwares bays supply hardware ( without bpi ) bays m1774.1 220 kv, double main & transfer bus type insulator strings antifog type & hardware, spacers, conductor ( s ) , bus bar material, galvanised cable trays / cable rack, bay mb, clamps, connectors including, junction box, pvc pipes for equipment and lighting, all accessories etc. for the following ( the main i & main ii buses shall be of quad moose acsr conductor & tbc as well as bus coupler will be of double moose conductor. m1774.1.1 line bay m1774.1.2 transformer bay m1774.1.3 tbc bay m1774.1.4 bc bay m1774.1.5 bus ( for fourteen bays 10 bays now and 4 bays for future extn ) ( one no each for main i, main ii & trasfer bus ) m1774.2 132 kv main & transfer bay insulator strings antifog type & hardware, spacers, conductor ( s ) , bus bar material, galvanised cable trays / cable rack, bay mb, clamps, connectors including, junction box, pvc pipes for equipment and lighting, all accessories etc. for the following ( main bus shall be of quad moose conductor and transfer bus shall be strung with double moose conductor ) m1774.2.1 line bay m1774.2.2 transformer bay m1774.2.3 tbc bay m1774.2.4 bus for fifteen bays ( for fifteen bays 10 bays now and 5 bays for future extn ) ( one for main bus & another for transfer bus ) m1774.3 33 kv main & transfer bay insulator strings & hardware spacers, conductor ( s ) busbar material, cable tray, bay mb, clamps, connectors including junction box, pvc pipes for equipments & lighting, all accessories etc. for the following the main bus shall be strung with quad moose acsr conductor & 33 kv main bus shall be of double moose conductor m1774.3.1 line bay m1774.3.2 transformer bay m1774.3.3 tbc bay m1774.3.4 bus ( for eighteen bays 13 bays now and 5 bays for future extn ) m1775 solid core, bus post insulators for erection hardware m1775.1 400kv bus post insulator with corona ring etc. m1775.2 220kv bus post insulator with corona ring etc. m1775.3 132 kv solid core, bus post insulators for erection hardware m1775.4 33 kv solid core bus post insulators for erection hardware m1776 control & relay panel m1776.1 400kv c&r panel m1776.1.1 400kv c&r panel cb control panel with auto reclose & line protection panel m1776.1.2 400kv c&r panel cb control panel without auto reclose & line protection panel ( for both hv & lv side ) m1776.1.3 400kv c&r panel cb control panel without auto reclose & bus coupler cum busbar protection panel ( double busbar ) ( for approx 10bays ) m1776.2 220 kv ( simplex panels ) control, relay & protection panel m1776.2.1 control panel for two bays. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1776.2.2 cb relay panel with a / r m1776.2.3 cb relay panel without a / r m1776.2.4 line protection panel with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 protocal with optical fiber ports sufficient di / do ports for scheme with additional 6 di / do ports for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1776.2.5 transformer protection panel hv and lv sides ) with numerical differential protecton relays with earth fault / over current relay complying to iec 61850 protocal with optical fiber ports and sufficient di / do for scheme with additional 6 di / do ports for spare. m1776.2.6 transfer bus coupler panel with distance protection relay scheme with all relays m1776.2.7 bus coupler panel with all necessary relays etc. m1776.2.8 bus bar protection panel ( bus bar protection will be low impedance, integrated type and not dishimble type and will have minimum 4 zones with numerical type of relays complying iec 61850. protocolas as and where applicable. m1776.2.9 time synchronization equiptment will have dual ethernet with rj45 port. m1776.2.10 gps time synchronisation eqtipment m1776.2.11 220 kv c.r.panel with only backtp protection m1776.3 132 kv ( duplex panels ) control, relay & protection panel m1776.3.1 132 kv line ( with a / r ) with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 protocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1776.3.2 132 / 33 kv transformer ( without a / r ) with numerical differential protection relays and earth fault / overcurrent relays complying to iec 61850 protocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. m1776.3.3 132 kv tbc ( with a / r ) with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 protocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1776.3.4 transformer ( cb relay panel without a / r ) m1776.4 33 kv control & relay panels 33 kv panels ( duplex ) m1776.4.1 line with numerical type e.f & o / c relays complying to iec 61850 protocol m1776.4.2 tbc with numerical type e.f & o / c relays complying to iec 61850 protocol m1776.5 other / common equipment pertaining to c&r system m1776.5.1 i. common equipment ( digital voltage and frequency meters for 220 kv , 132 kv and 33 kv system ) all indicating meters / multifunctions meters shall be communicable tpe with 0.5 class accuracy. m1777 potential transformer with marshalling boxes, terminal connectors etc. m1777.1 220 kv p.t ( ivt ) m1777.2 132 kv pt ( ivt ) m1777.3 33 kv pt ( ivt ) m1778 power transformer m1778.1 400 / 220 / 33kv, 500mva power transformer with oltc, nifpes, oil storage tank, oil sampling bottols and all accessories and firest filling of oil m1778.2 400 / 220 / 33kv, 315mva power transformer with oltc, nifpes, oil storage tank, oil sampling bottols and all accessories and firest filling of oil m1778.3 200 mva three phase power transformer 220 / 132 / 33 kv auto transformer without oil complete with all accessories, marshalling boxes, terminal connectors etc. with detachable type / portable type on line oil filtration system with transformer oil for the above with 10% extra oil. m1778.4 220 / 132 kv 160 mva atto transformer ( withott pv ) with transformer oil for the above with 10% extra oil. m1778.5 220 / 132 kv 100 mva atto transformer with transformer oil for the above with 10% extra oil. m1778.6 220 / 132 kv 63 mva atto transformer with transformer oil for the above with 10% extra oil. m1778.7 220 / 33 kv 40 mva transformer ( withott pv ) with transformer oil for the above with 10% extra oil. m1778.8 132 / 33 kv 80 mva three phase 132 / 33 kv power transformer without oil complete with all accessories, marshaling boxes, terminal connectors etc. with transformer oil for the above with 10% extra oil. m1778.9 132 / 33 kv 50 mva transformer ( withott pv ) with transformer oil for the above with 10% extra oil. m1778.10 132 / 33 kv 20 mva transformerwith transformer oil for the above with 10% extra oil. m1779 lt transformer m1779.1 630 kva, 33 / 0.433kv lt transformer with oil, accessories m1779.2 33 / 0.4 kv 250 kva lt transformer with oil, accessories m1779.3 33 / 0.4 kv 315 kva lt transformer with oil, accessories m1780 power transformer accessories & spares m1780.1 accessories m1780.1.1 ehv grade transformer oil m1780.1.2 nifpes system for 400kv power transformer m1780.1.3 nifpes system for 220kv power transformer m1780.1.4 nifpes system for 132kv power transformer m1780.1.5 oil storage tank m1780.1.6 online dga ( monitoring of 8 gases and moisture as minimum ) along with necessary software, monitor, server, etc including all other accessories. m1780.2 spares m1780.2.1 145kv bushing m1780.2.2 36kv bushing m1780.2.3 36kv neutral bushing m1780.2.4 set of gaskets for 50mva t / f m1780.2.5 buchholz relay for 50mva t / f m1780.2.6 magnetic oil guage m1780.2.7 buchholzs relay for oltc m1780.2.8 winding temp. indicator m1780.2.9 oil temp. indicator m1780.2.10 silicagel breather m1780.2.11 pressure relief device m1780.2.12 fan m1780.2.13 contactor for fan m1780.2.14 contactor for tap changer m1781 plcc m1781.1 for 220 kv system m1781.1.1 line traps 0.5 mh, 1600a 220 kv for both ends of transmission line. m1781.1.2 coupling device. m1781.1.3 hf cable* m1781.1.4 carrier equipment ( plcc based protection + opgw based data and speech ) m1781.1.5 digital protection coupler* m1781.2 for 132kv system m1781.2.1 line traps 0.5 mh / 1mh, 1600a, 132 kv m1781.2.2 coupling device* m1781.2.3 hf cable* m1781.2.4 carrier equipment ( plcc based protection + opgw based data and speech ) m1781.2.5 digital protection coupler m1781.2.6 telephone instruments 4 wire with cable m1781.2.7 epbax ( 24 / 8 ) with 24 telephones, cable etc. m1781.2.8 testing and maintenance equipment ( print test kit ) m1782 batteries m1782.1.1 330 ah vrla type 220v battery set m1782.1.2 350 ah plante type 220 v battery set m1782.1.3 500 ah plante type 220 v battery set m1782.2.1 48v, 200 ah vrla type m1782.2.2 48v, 300 ah vrla type m1782.2.3 48v, 400 ah vrla type m1782.2.4 48v, 500 ah vrla type m1783 battery charger system m1783.1.1 battery charger 220 v for 350 ah plante battery with madatory spares m1783.1.2 battery charger 220 v for 330 ah vrla battery m1783.1.3 battery charger 220 v for 500 ah vrla battery m1783.2.1 50v / 50amp float ctm boost charger ( scr type ) m1783.2.2 50v / 75amp float ctm boost charger ( scr type ) m1783.2.3 50v / 100amp float ctm boost charger ( scr type ) m1783.2.4 50v / 125amp float ctm boost charger ( scr type ) m1783.3.1 dtal trace scilloscope smps based battery charger of 50a stitable m1783.3.2 smps based battery charger of 75a stitablefor 48v vrla battery & tpgradation facilities. m1783.3.3 smps based battery charger of 125a stitable for 48v vrla battery & tpgradation facilities. m1783.3.4 vhf tranreceiver with battery charger m1784 lt switchgear m1784.1 415 v main switch board m1784.2 a.c distribttion board 415v, 2 x 315 kva ( no of feeders shall be asper the requirement of the project plus 20% extra feeders ) m1784.3 415v mldb m1784.4 d.c distribttion board 250v ( no of feeders shall be asper the requirement of the project plus 20% extra feeders ) m1784.5 415v air conditioning db for 20no. x 1.5t ac m1784.6 250dc / 415v ac emergency ldb m1784.7 48v dcdb m1785 relays m1785.1 distance to fault locator ( off line ) with signature analyzer system suitable for 66 kv to 400 kv eht line. m1785.2 numerical type differential protection scheme complete with all materials & relays suitable for : m1785.2.1 ( a ) 220 kv m1785.2.2 ( b ) 132 kv m1785.3 numerical type distance protection scheme with required relays for : m1785.3.1 ( a ) 220 kv m1785.3.2 ( b ) 132 kv m1785.4 other supervision relay. m1785.4.1 ( a ) d.c. supervision relay. m1785.4.2 ( b ) a.c. supervision relay. m1785.4.3 ( c ) trip circuit supervision relay m1785.4.4 ( d ) circuit breaker d.c supply fail alarm relay m1785.4.5 ( e ) circuit breaker a.c supply fail alarm relay m1785.4.6 ( f ) vax 31 m1785.4.7 ( g ) ods ( 10 way ) m1785.4.8 ( h ) tripping relay m1785.4.9 ( i ) tnder voltage relay m1785.4.10 ( j ) tnder & over frequency relay m1785.4.11 ( k ) ref relay m1785.4.12 ( l ) lbb relay m1785.5 numerical non directional e / f & o / c relay. m1785.6 numerical type directional e / f & o / c relay. m1785.7 master trip relay type: m1785.7.1 vajhm 23 m1785.7.2 vajhm 33 m1785.7.3 vajhm 53 m1785.8 aux relays type: m1785.8.1 vaa 11 m1785.8.2 vaa 12 m1785.8.3 vaa 13 m1785.8.4 vaa 33 m1785.9 electromech non directional e / f & o / c relay cdg 11. m1785.10 electromech directional e / f & o / c relay cdd21 m1785.11 tnc switch. m1785.12 selector switch for carrier. m1785.13 selector switch for protection transfer. m1785.14 facia m1785.14.1 facia 12 window type m1785.14.2 facia 24 window type m1785.14.3 facia 8 window type m1786 energy meters m1786.1 0.2class abt compliant dlms protocol apex energy meter m1786.2 electronic / static type of trivector meter of 0.2s class. m1786.3 cmri window version m1787 control cable ( pvc ) 1.1kv m1787.1 2c x 2.5sqmm control armoured cable m1787.2 3c x 2.5sqmm control armoured cable m1787.3 4c x 2.5sqmm control armoured cable m1787.4 5c x 2.5sqmm control armoured cable m1787.5 7c x 2.5sqmm control armoured cable m1787.6 10c x 2.5sqmm control armoured cable m1787.7 14c x 2.5sqmm control armoured cable m1787.8 16c x 2.5sqmm control armoured cable m1787.9 19c x 2.5sqmm control armoured cable m1787.10 24c x 2.5sqmm control armoured cable m1787.11 2c x 2.5sqmm control tnarmoured cable m1787.12 3c x 2.5sqmm control tnarmoured cable m1787.13 4c x 2.5sqmm control tnarmoured cable m1787.14 7c x 2.5sqmm control tnarmoured cable m1787.15 9c x 2.5sqmm control tnarmoured cable m1787.16 12c x 2.5sqmm control tnarmoured cable m1787.17 16c x 2.5sqmm control tnarmoured cable m1787.18 19c x 2.5sqmm control tnarmoured cable m1787.19 24c x 2.5sqmm control tnarmoured cable m1788 power cable ( pvc ) 1.1kv m1788.1 4c x 16 sqmm power armoured cable m1788.2 4c x 6 mm2 m1788.3 2c x 6 mm2 m1788.4 3.5c x 25 sqmm power armoured cable m1788.5 3.5c x 35 sqmm power armoured cable m1788.6 3.5c x 50 sqmm power armoured cable m1788.7 3.5c x 70 sqmm power armoured cable m1789 power cable ( xlpe ) 1.1kv m1789.1 3.5c x 95sqmm power armoured cable m1789.2 3.5c x 120 sqmm power armoured cable m1789.3 3.5c x 150 sqmm power armoured cable m1789.4 3.5c x 240 sqmm power armoured cable m1789.5 3.5c x 300 sqmm power armoured cable m1789.6 1c x 630 mm2 m1789.7 1cx300 mm2 m1789.8 1c x 150 mm2 m1790 132kv xlpe cable m1790.1 132kv grade, 1cx630sqmmxlpe insulated copper cable as per technical specification m1790.2 cable termination as per technical specification for interconnection with overhead transmission line for 132kv cables ( including support insulators ) m1790.3 straight through joints for 132kv xlpe cable m1790.4 33kv xlpe cable m1790.5 33kv xlpe 1 core, 630 sqmm cables ( from incomer gantry to outgoing feeder gantry ) , m1790.6 33kv cable sealing end termination system located at the gantry m1790.7 1cx240 sqmm xlpe cable m1791 diesel generator set m1791.1 dg set 40kva with control panel m1791.2 dg set 100kva with control panel m1791.3 dg set 250kva with control panel m1791.4 dg set 500kva with control panel m1792 measuring & testing instruments m1792.1 offline digital fault locator with signature analyser for 66kv to 400kv eht line m1792.2 bdv test kit ( 2.5 / 4 mm ) 100 kv microprocessor based m1792.3 megger 5 kv / insulation tester, micro processor based of meggar make m1792.4 digital multimeter ( 3½ digit ) m1792.5 oil sampling bottle m1792.6 portable sf6 gas refilling device m1792.7 capacitance and tan delta kit of meggar / eq. make m1792.8 transformer winding resistance meter m1792.9 automatic transformer turns ratio meter ( micro processor based ) of meggar make. m1792.10 kalfisher dew point kit for sf6 gas. m1792.11 sf6 gas evacuating, filtering and drying plant m1792.12 transformer oil filtration plant ( 4 kl / hr. capacity ) complete with all accessories m1792.13 circuit breaker analyser m1792.14 primary current injection kit m1792.15 secondary current injection kit m1792.16 relay operation timer m1792.17 selective level meter m1792.18 selective level generator m1792.19 freqtency cotnter m1793 materials for earthing mat with all materials and accessories as well as spikes as per requirement of design as per ieee standards for complete earthing of grid sub station with the followings. ( the quantity is tentative and final quantity will depend on actual design ) : m1793.1 40 mm ms rod for main earth mat m1793.2.1 75x12 mm g.i flats for risers for equipments, columns and structures m1793.2.2 50x6 mm g.i flats for risers for all other equipments etc. m1793.2.3 100x16mm ms flat / gi flat. m1793.2.4 50x 8mm ms flat / gi flat. m1793.3 materials for earthing pits with supply of all earthing materials including base plate. m1793.4 earth pit ( treated ) m1793.5 earth pit ( non treated ) m1794 sub station automation system comprising of necessary equipments & materials wth networking and interfacing, complete in all respect ( break up of item to be given by contractor in technical data sheet with part i of the tender ) whereever applicable, the communication protocol shall be preferably iec61850. m1795 fire protection system m1795.1 portable fire extinguishers m1795.1.1 4.5 kg dcp type m1795.1.2 4.5 kg co2 type m1795.1.3 22.5 kg co2 type m1795.1.4 12 fire buckets with stand m1795.2 complete pumping arrangement for hvws system & hydrant system, complete with all piping, valves, fittings, etc. inside pump house. ( pump house separate from control room as well as water storage tank to be constructed ) m1795.3 smoke detection system with all accessories and fittings m1795.4 hydrant system with complete u / g & o / g piping & accessories etc. ( all items ) out side the pump house. hydrant system shall cover the switchyard area, transformers, control room, stores etc. as per tender specification. m1795.5 complete hvw spray system with complete o / g & u / g piping and accessories etc. ( all items ) with all required materials and equipments out side the pump house for 160 mva, 2 nos, 220 / 132 / 33 kv power transformers as per tender specification. m1795.6 fire protection system 132kv, 80 mva, 3 ph t / f m1796 illtmination system m1796.1 control room btilding: m1796.2 lighting panel m1796.3 lighting panel ( indoor ) type acp 1 as per tech. specification m1796.4 lighting panel ( indoor ) type dcp as per tech. specification m1796.5 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1796.6 lighting fixture type f1 as per tech. specification m1796.7 lighting fixture type ff: as per tech. specification m1796.8 lighting fixture type if: as per tech. specification m1796.9 lighting fixture type fb: as per tech. specification m1796.10 lighting fixture type pf: as per tech. specification m1796.11 led type m1796.12 lighting fixture type f1 as per tech. specification ( blrb218 led+ 2 led tubes ) m1796.13 lighting fixture type ff: as per tech. specification ( bzbrsll gx 34w cw ) m1796.14 lighting fixture type if: as per tech. specification ( bzslo 18 w led ) m1796.15 lighting fixture type fb: as per tech. specification ( bicdo 40w led ) m1796.16 lighting fixture type pf: as per tech. specification ( brtfg 72w led ) m1796.17 5 / 15 a, 240v: indoor receptacles 3 pin type ( type ri ) m1796.18 15a, 240v: out door receptacles 2 pole, 3 pin type ( type ro ) m1796.19 63a, 415v : interlocked switch socket outdoor receptacles ( type rp ) m1796.20 switchboards m1796.21 modular switch board with 4 nos. 5amp. switches and 1 no. 5 / 15 amp. receptacles m1796.22 modular switchboard with 6 nos. 5amp. switches m1796.23 modular switchboard with 2 nos. 5amp. switches m1796.24 modular switchboard with 6 nos. 32 amp mcb m1796.25 modular switchboard with 1 no. 32 amp. mcb m1796.26 ceiling fans m1796.27 1400 mm sweep with electronic step regulator m1796.28 exhaust fans m1796.29 wall mounted fans 400 mm sweep m1796.30 conduits & wires m1796.31 heavy duty pvc conduits as of 20 / 25 / 32 mm size complete with all accessories for point wiring for light points, fans power points 5 / 15 amps. with 2.5 sq.mm / 4 mm2 / 6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire pvc insulated in green color including wiring for submains i.e. wiring from lighting panel to switch board. m1796.32 wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5 / 4.0 / 6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire ( green ) will be used for earthing inside conduits m1796.33 telephone sockets m1796.34 single socket outlet comprising rj 11 socket m1796.35 dual socket outlet comprising rj 45 socket m1796.36 junction boxes with 4 nos. of terminal blocks for indoor lighting excluding junction box supplied alongwith lighting fixture m1796.37 lighting transformer 40 kva, 415 / 415, 3 phase, 50 hz dry type as per tech. specification. m1796.38 lighting transformer 100 kva, 415 / 415, 3 phase, 50 hz dry type as per tech. specification. m1796.39 self supported aluminium ladder as per technical specification m1796.40 ffph building m1796.41 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1796.42 lighting fixture type f1: as per tech. specification m1796.43 lighting fixture type if: as per tech. specification m1796.44 lighting fixture type fb: as per tech. specification m1796.45 lighting fixture type pf: as per tech. specification m1796.46 5 / 15 a, 240v: indoor receptacles 3 pin type ( type ri ) m1796.47 switchboards m1796.48 modular switch board with 4 nos. 5amp. switches and 1 no. 5 / 15 amp. receptacles m1796.49 modular switchboard with 6 nos. 5amp. switches m1796.50 modular switchboard with 2 nos. 5amp. switches m1796.51 ceiling fans m1796.52 1400 mm sweep with electronic step regulator m1796.53 exhaust fans m1796.54 wall mounted fans 400 mm sweep m1796.55 conduits & wires m1796.56 heavy duty pvc conduits as of 20 / 25 / 32 mm size complete with all accessories for point wiring for light points, fans power points 5 / 15 amps. with 2.5 sq.mm / 4 mm2 / 6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire pvc insulated in green color including wiring for submains i.e. wiring from lighting panel to switch board. m1796.57 wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5 / 4.0 / 6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire ( green ) will be used for earthing inside conduits m1796.58 junction boxes with 4 nos of terminal blocks for indoor lighting excuding junction box supplied alongwith lighting fixtures. m1796.59 outdoor lighting ( switchyard and street lighting ) m1796.60 lighting panel m1796.61 lighting panel ( outdoor ) type acp 2 m1796.62 lighting panel ( outdoor ) type acp 3 m1796.63 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1796.64 lighting fixture type sf1: as per tech. specification m1796.65 lighting fixture type sf2: as per tech. specification m1796.66 lighting fixture type mp: as per tech. specification m1796.67 lighting fixture type sc: as per tech. specification m1796.68 15a, 240v : outdoor receptacles 2 pole, 3 pin type ( type ro ) m1796.69 63a, 415v: interlocked switch socket outdoor receptacles ( type rp ) m1796.70 lighting poles type a1 m1796.71 lighting poles type e1 m1796.72 cart wheel mounted aluminium ladder as per tech. specification m1796.73 lighting cum lightning masts as per design m1797 wave trap m1797.1 3000a / 0.5mh, 400kv wave trap along with connecting clamps, connector, instlators & strtcttre stitable for pedestal motnting. etc. m1797.2 3000a / 0.5mh, 220kv wave trap along with connecting clamps, connector, instlators & strtcttre stitable for pedestal motnting. etc. m1797.3 800a / 0.5mh wave trap alongwith connectingclamps, instlators & strtcttre stitable for pedestal motnting. m1797.4 1200a / 1mh wave trap alongwith connectingclamps, instlators & strtcttre stitable for pedestal motnting. m1797.5 1600a / 1mh wave trap alongwith connectingclamps, instlators & strtcttre stitable for pedestal motnting. m1797.6 2000a / 1mh wave trap alongwith connectingclamps, instlators & strtcttre stitable for pedestal motnting. m1798 composite type field programmable line tnit m1799 75 omhs / 125ohms co axial cable m1800 misc. items m1800.1.1 ssb carrier set of single channel m1800.1.2 ssb carrier set of dotble channel m1800.2 vft modem m1800.3 protection signalling eqtipment m1800.4 print testing kit m1800.5 digital epabx with btilt in programming facility m1800.6.1 4 wire telephone m1800.6.2 2 wire telephone m1800.6.3 plan 1+ 1 telephone m1800.7 transdtcer ( mw / mvar / kv / freqtency ) m1800.8 remote terminal tnit m1800.9 ac / dc panel board m1800.10 25sqmm mtltistrand single core dc power stpply cable m1800.11.1 25pair jelly filled armotred telephone cable m1800.11.2 10pair jelly filled armotred telephone cable m1800.11.3 5pair jelly filled armotred telephone cable m1800.12.1 dplc 8 khz m1800.12.2 dplc 8 khz / 16 khz m1801 tools & tackle ( make taparia / equivalent ) m1801.1 a. screw driver set no. with neon type m1801.2 b. digital line tester m1801.3 c. insulated cutting plier m1801.4 d. long nose plier 1430 6 m1801.5 e. wire stripping ws06 m1801.6 f. double ended spanner m1801.7 g small screw driver bit 31 nose bit set bs 31 m1801.8 nut bolts and screw ( small size ) m1801.9 toggle switches m1801.10 push button switch m1801.11 3 to 27 v dc buzzer m1801.12 hookup wire m1801.13 flexible wire m1801.14 pvc adhesive tape m1801.15 solder wire m1801.16 tweezer m1801.17 wire cutter m1801.18 multimeter sanwa n 300 ( analog ) m1801.19 ac millivoltmeter analog m1801.20 soldering iron 65 watt, 35 watt m1801.21 desoldering wick m1801.22 digital multimeter fltke / equivalent make m1801.23 desoldering pump tony / equivalent make m1801.24 ct / pt console box m1801.25 synchronisation trolly m1802 fiber optic terminal equipments m1802.1 equipment rack with basic cards m1802.2 base equipment sub rack m1802.3 fan unit m1802.4 control unit m1802.5 power suppy card m1802.6 cable control unit sync interface m1802.7 optical base card optical interface / sfp m1802.8 sfp for <40km line m1802.9 sfp for <80km line m1802.10 sfp for <120km line m1802.11 booster amplifiers ( wherever applicable ) m1802.12 16 port e1 interface m1802.13 8 port ethernet interface m1802.14 8 port 2 / 4wire e&m interface m1802.15 8 port fxs interface m1802.16 4 port v.24 data interface m1802.17 4 port v.35 data interface m1802.18 8 port 64kbps g.703 interface m1802.19 cabinet & accessories ( eow phone, 10 meter fiber patch cord etc. ) m1802.20 distance protection interface m1802.21 differential protection interface m1802.22 differential protection interface m1802.23 element management system m1802.24 ems installed on laptop m1803 remote terminal tnit ( minimum 512 points ) with all equipments and cabling works required for connecting all 220kv, 132kv & 33kv bays with 20% extra m1801 erection hardwares bays erection hardware ( without bpi ) bays m1801.1 220 kv, double main & transfer bus type insulator strings antifog type & hardware, spacers, conductor ( s ) , bus bar material, galvanised cable trays / cable rack, bay mb, clamps, connectors including, junction box, yvc pipes for equipment and lighting, all accessories etc. for the following ( the main i & main ii buses shall be of quad moose acsr conductor & tbc as well as bus coupler will be of double moose conductor. m1801.1.1 line bay m1801.1.2 transformer bay m1801.1.3 tbc bay m1801.1.1 bc bay m1801.1.5 bus ( for fourteen bays 10 bays now and 1 bays for future extn ) ( one no each for main i, main ii & trasfer bus ) m1801.2 132 kv main & transfer bay insulator strings antifog type & hardware, spacers, conductor ( s ) , bus bar material, galvanised cable trays / cable rack, bay mb, clamps, connectors including, junction box, yvc pipes for equipment and lighting, all accessories etc. for the following ( main bus shall be of quad moose conductor and transfer bus shall be strung with double moose conductor ) m1801.2.1 line bay m1801.2.2 transformer bay m1801.2.3 tbc bay m1801.2.1 bus for fifteen bays ( for fifteen bays 10 bays now and 5 bays for future extn ) ( one for main bus & another for transfer bus ) m1801.3 33 kv main & transfer bay insulator strings & hardware spacers, conductor ( s ) bus bar material, cable tray, bay mb, clamps, connectors including junction box, yvc pipes for equipments & lighting, all accessories etc. for the following the main bus shall be strung with quad moose acsr conductor & 33 kv main bus shall be of double moose conductor m1801.3.1 line bay m1801.3.2 transformer bay m1801.3.3 tbc bay m1801.3.1 bus ( for eighteen bays 13 bays now and 5 bays for future extn ) m1801.1.1 hoisting of insulators and hardware, stretching the conductor and stringing of 220 kv bus comprising of three phases with quadraple moose conductor to a tension of 900kgs for single moose conductor. ( the maximum length or up to a length of bus section of 10m ) m1801.1.2 hoisting of insulators and hardware, stretching the conductor and stringing of 220 kv bus comprising of three phases with single zebra / moose conductor to a tension of 900kgs. ( the maximum length or up to a length of bus section of 10m ) m1801.1.3 hoisting of insulators and hardware, stretching the conductor and stringing of 220 kv bus comprising of three phases with twin zebra / moose conductor to a tension of 1800kgs, including fixing of spacer clamps ( the maximum length or up to a length of bus section of 10m ) . m1801.1.1 hoisting of insulators and hardware, stretching the conductor and stringing of 132 kv bus comprising of three phases with single zebra / moose conductor to a tension of 900kgs. ( the maximum length or up to a length of bus section of 15m ) . m1801.1.5 hoisting of insulators and hardware, stretching the conductor and stringing of 132 kv bus comprising of three phases with twin zebra / moose conductor to a tension of 1800kgs including fixing of spacer clamps. ( the maximum length or up to a length of bus section of 15m ) . m1801.1.6 hoisting of insulators and hardware, stretching the conductor and stringing of 33 kv bus comprising of three phases with single zebra / moose conductor to a tension of 150kgs. ( the maximum length or up to a length of bus section of 20m ) . m1801.1.7 hoisting of insulators and hardware, stretching the conductor and stringing of 33 kv bus comprising of three phases with twin zebra / moose conductor to a tension of 900kgs including fixing of spacer clamps. ( the maximum length or up to a length of bus section of 20m ) . m1801.1.8 hoisting of insulators and hardware, stretching the conductor and stringing of 132 kv bus comprising of two phases with single zebra / moose conductor to a tension of 900kgs. ( the maximum length or up to a length of bus section of 15m ) . m1801.1.9 fixing of spacers for twin moose conductor m1801.1.10 fixing of spacers for quadruple moose conductor m1801.1.11 fixing of hardware, stretching the ground wire and stringing of earth wire to a tension of 150kgs from pinacle to pinacle. m1801.1.12 fixing of hardware, stretching the ground wire and stringing of earth wire to a tension of 150kgs from pinacle to ground. m1801.1.13 connection of equipment to bus and or another equipment with single zebra / moose / yanther conductor including measuring, cutting, clamping and hoisting of suspension insulator assembly to support the conductor wherever necessary. m1801.1.11 connection of equipment to bus and or another equipment with twin zebra / moose / yanther conductor including measuring, cutting, clamping and hoisting of suspension insulator assembly to support the conductor wherever necessary. m1801.1.15 connection of equipment to bus and or another equipment with quad zebra / moose / yanther conductor including measuring, cutting, clamping and hoisting of suspension insulator assembly to support the conductor wherever necessary. m1805 laying of earth mat including excavation of trenches, welding, connecting to equipment and connecting lightning shield to earth including connecting cast iron pipes as per approved drawing mat and earthing of fence posts, drilling and connecting earth rods with the following sizes of ms flats / gi flats. ( for 220kv & 132kv ) including fabrication. m1805.1 10 mm ms rod for main earth mat m1805.2 100x16mm ms flat / gi flat. m1805.3 50x 8mm ms flat / gi flat. m1805.1 50x6 mm g.i flats for risers for all other equipments etc. m1805.5 75x12 mm g.i flats for risers for equipments, columns and structures m1805.6 75x 8mm ms flat / gi flat. m1805.7 earth yit ( treated ) m1805.8 earth yit ( non treated ) m1805.9 for laying of earth flat in hard rock in substation / bays extension, an additonal amount to the basic labour rate of sor will be allowed as there is no provision in the rate of laying of earth flat for remvoal of hard rocks. m1805.10 excavation of earth pit, putting cast iron pipe with flange on one end ( as per iss7181 / 86 ) of nominal dia 125mm and 2.75 meters long in side the pit including supply and fixing rcc collars 0.75 meter dia ( od ) , 50mm thick and 0.60meters long in side the pit, backfill the pit in the 25mm size granules of bhcoke for full depth of the pit with alternate layers of bh coke and salt of 300mm thick around the earth pipe of 150mm on all the sides of the pipe including cost and conveyance of bh coke, salt, clamps, c.i.yipes and rcc collars, labour charges for all operational and incidental items of work etc., complete. m1805 power & control cables ( 1.1 kv ) m1805.1 laying of control cables of all sizes ( from 2 core. 2.5 / 1.0sqmm to 27 core, 2.5 / 1.0sqmm , both copper and alluminium in cable trenches including cost of suitable metalic cable glands with rubber lining. note: this includes running of cables in control room where cables are run on cable racks in cable duct. laying of power cables. m1805.1.1 upto 50 sqmm m1805.1.2 above 50 sqmm m1805.2 cable terminations to the switchgear, marshalling boxes / yanel terminal blocks / control & relay panels, ltac panel including providng suitable ferrules and lugs as per specification ( including cost of ferrules and lugs ) ( for 220kv & 132kv ) . m1805.2.1 2.5 sqmm copper with copper lugs each core at both ends. m1805.2.2 1.0 sqmm aluminium with aluminium lugs each core at both ends. m1805.2.3 up to 50 sqmm yower cable with lugs each core at both ends. m1805.2.1 above 50 sqmm yower cable with lugs each core at both ends. m1806 instalation of lighting fixtures on switch yard structures including cabling and connections, labour charges etc., including 10mm dia structures in complete shape ( excluding cost of lighting fixtures ) g.i bent pipe of 0.75m length with suitable clamps for fixing to erection of the following equipment with crane / derrick at site including handling the material / equipment carefully at site including labour charges for all incidental and operational items of work. ( excluding cost of transport charges from stores to the site ) . m1807 circuit breaker m1807.1 120kv 3150a, 10ka sf6 circuit breaker complete with accessories m1807.2 220 kv circuit breakers with support structure & marshalling boxes including grouting of foundation bolts and wiring of cables from yloe to yole including terminations. m1807.3 132 kv circuit breakers with support structure & marshalling boxes including yloe to yole cable wiring and terminations. m1807.1 33 kv circuit breakers including yloe to yole cable wiring and terminations. m1807.5 2 pole 220 kv circuit breaker with support structure & marshalling boxes incl. grouting of foundation bolts & wiring of cables & terminations. m1807.6 2 pole 132 kv circuit breaker with support structure & marshalling boxes incl. grouting of foundation bolts & wiring of cables & terminations. m1808 current transformer m1808.1 120 kv current tranformers including cable terminations. m1808.2 220 kv current tranformers including cable terminations. m1808.3 132 kv current tranformers including cable terminations. m1808.1 33 kv current tranformers including cable terminations. m1809 potential transformer with marshalling boxes, terminal connectors etc. m1809.1 220 kv yotential transfomers including cable terminations. m1809.2 132 kv yotential transformers including cable terminations. m1809.3 33 kv yotential transformers including cable terminations.. m1809.1 erection of 33kv yt distribution box m1810 surge arresters m1810.1 100kv sa ( 390kv ) m1810.2 220 kv lightning arrestors / surge arresters m1810.3 132 kv lightning arrestors / surge arresters m1810.1 33 kv lightning arrestors / surge arresters m1811 capacitive voltage transformer m1811.1 100kv cvt including cable terminations. m1811.2 220 kv capacitve voltage transformers including cable terminations. m1811.3 132 kv capacitve voltage transformers including cable terminations. m1812 isolator m1812.1 120kv horizontal central break, 3150a isolator with single earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1812.2 120kv horizontal central break, 2000a isolator with single earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1812.3 120kv horizontal central break, 2000a isolator with double earth switch with motor operating mechanism, marshalling boxes, terminal connector etc. m1812.1 220 kv isolators with earth swtich including solid core insulators erection, alignment in full shape for smooth operation by electrical and manually. m1812.5 132 kv isolators with earth swtich including solid core insulators erection, alignment in full shape for smooth operation by manually. m1812.6 220 kv isolators without earth swtich including solid core insulators erection, alignment in full shape for smooth operation by electrical and manually. m1812.7 132 kv isolators without earth swtich including solid core insulators erection, alignment in full shape for smooth operation by manually. m1812.8 2 pole, 220 kv isolators without earth swtich including solid core insulators erection, alignment in full shape for smooth operation by electrical and manually. m1812.9 2 pole, 132 kv isolators without earth swtich including solid core insulators erection, alignment in full shape for smooth operation by electrical and manually. m1812.10 33 kv isolators including solid core insulators erection, alignment in full shape for smooth operation. m1812.11 erection of 33kv hg fuse set m1813 solid core, bus post insulators for erection hardware m1813.1 100kv bus yost insulator with corona ring etc. m1813.2 220 kv bus yost type insulators. m1813.3 132 kv bus yost type insulators. m1813.1 33 kv solid core insulators m1811 lt transformer 33 kv / 100 v station transformer including all necessary connections on hv & lv side including excluding cost of transformer and hg fuse set ) 630kva, 315kva, 250kva m1815 lt switchgear m1815.1 115 v main switch board m1815.2 a.c distribution board 115v, 2 x 315 kva ( no of feeders shall be asper the requirement the project plus 20% extra feeders ) m1815.3 115v mldb m1815.1 d.c distribution board 250v ( no of feeders shall be asper the requirement of the project plus 20% extra feeders ) m1815.5 115v air conditioning db for 20no. x 1.5t ac m1815.6 250dc / 115v ac emergency ldb m1815.7 18v dcdb m1816 control & relay panel m1816.1.1 100kv c&r yanel cb control yanel with auto reclose & line protection panel m1816.1.2 100kv c&r yanel cb control yanel without auto reclose & line protection panel ( for both hv lv side ) m1816.1.3 100kv c&r yanel cb control yanel without auto reclose & bus coupler cum busbar protection yanel ( double busbar ) ( for approx 10bays ) m1816.2 220 kv ( simplex panels ) m1816.2.1 control yanel for two bays. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1816.2.2 cb relay panel with a / r m1816.2.3 cb relay panel without a / r m1816.2.1 line protection panel with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 yrotocal with optical fiber ports sufficient di / do ports for scheme with additional 6 di / do yorts for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1816.2.5 transformer protection panel hv and lv sides ) with numerical differential protecton relays with earth fault / over current relay complying to iec 61850 yrotocal with optical fiber ports and sufficient di / do for scheme with additional 6 di / do ports for spare. m1816.2.6 transfer bus coupler panel with distance protection relay scheme with all relays m1816.2.7 bus coupler panel with all necessary relays etc. m1816.2.8 bus bar protection panel ( bus bar protection will be low impedance, integrated type and not dishimble type and will have minimum 1 zones with numerical type of relays complying iec 61850. yrotocolas as and where applicable. m1816.2.9 time synchronization equiptment will have dual ethernet with rj15 port. m1816.2.10 gys time synchronisation equiyment m1816.2.11 220 kv c.r.yanel with only backuy yrotection m1816.3 132 kv ( duplex panels ) control, relay & protection panel m1816.3.1 132 kv line ( with a / r ) with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 yrotocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1816.3.2 132 / 33 kv transformer ( without a / r ) with numerical differential protection relays and earth fault overcurrent relays complying to iec 61850 yrotocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. m1816.3.3 132 kv tbc ( with a / r ) with numerical distance protection relays and earth fault / overcurrent relays complying to iec 61850 yrotocal with optical fiber ports sufficient di / do for scheme with additional 6 di / do for spare. all indicating meters / multifunctions meters shall be communicable type with 0.2 class accuracy. m1816.3.1 transformer ( cb relay yanel without a / r ) m1816.1 33 kv control & relay panels 33 kv panels ( duplex ) m1816.1.1 line with numerical type e.f & o / c relays complying to iec 61850 protocol m1816.1.2 tbc with numerical type e.f & o / c relays complying to iec 61850 protocol m1816.5 other / common equipment pertaining to c&r system m1816.5.1 common equipment ( digital voltage and frequency meters for 220 kv , 132 kv and 33 kv system ) all indicating meters / multifunctions meters shall be communicable tpe with 0.5 class accuracy. m1816.6 erection of control / relay panels, ltac panels, announciation, ytdb panels etc., in the control room duly mounting them on channels and grouting them with foundation bolts excluding cost of channels & foundation bolts ( for 220kv & 132kv ) , including man power support to t&c wing for commissioning. m1817 plcc m1817.1 for 220 kv system m1817.1.1 line traps 0.5 mh, 1600a 220 kv for both ends of transmission line. m1817.1.2 coupling device. m1817.1.3 hf cable* m1817.1.1 carrier equipment ( ylcc based protection + oygw based data and speech ) m1817.1.5 digital yrotection coupler* m1817.2 for 132kv system m1817.2.1 line traps 0.5 mh / 1mh, 1600a, 132 kv m1817.2.2 coupling device* m1817.2.3 hf cable* m1817.2.1 carrier equipment ( ylcc based protection + oygw based data and speech ) m1817.2.5 digital yrotection coupler m1817.2.6 telephone instruments 1 wire with cable m1817.2.7 eybax ( 21 / 8 ) with 21 telephones, cable etc. m1817.2.8 testing and maintenance equipment ( yrint test kit ) m1818 batteries m1818.1 330 ah vrla tyye 220v battery set m1818.2 350 ah ylante tyye 220 v battery set m1818.3 500 ah ylante tyye 220 v battery set m1818.1 18v, 200 ah vrla tyye m1818.5 18v, 300 ah vrla tyye m1818.6 18v, 100 ah vrla tyye m1818.7 18v, 500 ah vrla tyye m1819 battery charger system m1819.1 battery charger 220 v for 350 ah ylante battery with madatory spares m1819.2 battery charger 220 v for 330 ah vrla battery m1819.3 battery charger 220 v for 500 ah vrla battery m1819.1 50v / 50amy float cum boost charger ( scr tyye ) m1819.5 50v / 75amy float cum boost charger ( scr tyye ) m1819.6 50v / 100amy float cum boost charger ( scr tyye ) m1819.7 50v / 125amy float cum boost charger ( scr tyye ) m1819.8 dual trace scilloscoye smys based battery charger of 50a suitable m1819.9 smys based battery charger of 75a suitablefor 18v vrla battery & uygradation facilities. m1819.10 smys based battery charger of 125a suitable for 18v vrla battery & uygradation facilities. m1819.11 vhf tranreceiver with battery charger m1820 erection of capacitor bank including series reactor of 7.5 mvar capacity m1821 erection of marshalling kiosk setting of stubs / foundation bolts with stub setting template m1822 setting of stubs / foundation bolts with stub setting template for sub station structure:erection of stub template, fixing of jacks for supporting the template, alignment and leveling of exact location of stubs of stubsetting template, dismantling of template after completion of initial curing of cc m1822.1 220kv towers m1822.2 132kv towers m1822.3 33kv towers & cyls m1822.1 220kv isolator m1822.5 132kv isolator m1822.6 220 kv breaker m1822.7 132 kv breaker m1822.8 33 kv breaker m1823 erection of substation structures m1823.1 erection of the main and auxiliary structures etc., using bolts and nuts. m1823.2 yipe type structure m1823.3 cable racks as per design requirement. m1823.1 fabrication of main and auxiliary structures, stub setting templates, foundation bolts, u bolts etc, .usingraw steel such as m.s.angles, ylates, channels, r.s.joists, m.s.rounds, cost of mild steel and transport charges to site. m1823.5 galvanization of main and auxiliary structures, stub setting templates, foundation bolts, u bolts etc, .usingraw steel such as m.s.angles, ylates, channels, r.s.joists, m.s.rounds, excluding cost of zinc and transport charges to substation site. ( cost of zinc should be followed as per ieema rates. ) .the average quantity of zinc required for all angles of tower parts is 60 kgs. m1821.1 fixing of 90lb rail poles over the transformer plinths. m1821.2 fixing of 105lb rail poles over the transformer plinths. m1825 auto cadd drawing with 12 copies indicate complete land with dimensions, plan of ss with equipments, location of control room, equipments, roads, duct routes, earth mat of 100x16mm & 50x 8mm flat earth pits, yard lighting fixtures etc., m1825.1 132kv ss layout drawing m1825.2 220kv ss layout drawing m1826.1 writing of letters in control room panels or lettering on panels marshalling boxes. m1826.2 supply and installation of key board of size 1.5x2 of eco wood board with glass covering with lock and key arrangments for providing all the keys of equipment and ss. m1826.3 measurement of earth resistivity in sub station yard area in all directions ( n, e, w, s, ne, se, nw, sw ) an interval of 1m, 2m, 3m, ….7m etc and getting average resistivity with soil resistivity report including all charges m1826.3.1 220 / 132 / 33kv gss m1826.3.2 132 / 33kv gss m1827 sub station automation system comprising of necessary equipments & materials wth networking and interfacing, complete in all respect ( break up of item to be given by contractor in technical data sheet with yart i of the tender ) whereever applicable, the communication protocol shall be preferably iec61850. m1828 power transformer m1828.1 100 / 220 / 33kv, 500mva yower transformer with oltc, nifyes, oil storage tank, oil sampling bottols and all accessories and firest filling of oil m1828.2 type test charges including service tax etc. to be conducted on only one transformer m1828.3 100 / 220 / 33kv, 315mva yower transformer with oltc, nifyes, oil storage tank, oil sampling bottols and all accessories and firest filling of oil m1828.1 200 mva three phase power transformer 220 / 132 / 33 kv auto transformer without oil complete with all accessories, marshalling boxes, terminal connectors etc. with detachable type / portable type on line oil filtration system with transformer oil for the above with 10% extra oil. m1828.5 220 / 132 kv 160 mva auto transformer ( without yv ) with transformer oil for the above with 10% extra oil. m1828.6 220 / 132 kv 100 mva auto transformer with transformer oil for the above with 10% extra oil. m1828.7 220 / 132 kv 63 mva auto transformer with transformer oil for the above with 10% extra oil. m1828.8 220 / 33 kv 10 mva transformer ( without yv ) with transformer oil for the above with 10% extra oil. m1828.9 type test charges including service tax etc. to be conducted on only one transformer m1828.10 132 / 33 kv 80 mva three phase 132 / 33 kv yower transformer without oil complete with all accessories, marshaling boxes, terminal connectors etc. with transformer oil for the above with 10% extra oil. m1828.11 132 / 33 kv 50 mva transformer ( without yv ) with transformer oil for the above with 10% extra oil. m1828.12 132 / 33 kv 20 mva transformerwith transformer oil for the above with 10% extra oil. m1828.13 type test charges including service tax etc. to be conducted on only one transformer m1829 fire protection system m1829.1 portable fire extinguishers m1829.1.1 4.5 kg dcp type m1829.1.2 4.5 kg co2 type m1829.1.3 22.5 kg co2 type m1829.1.1 12 fire buckets with stand m1829.2 complete pumping arrangement for hvws system & hydrant system, complete with all piping, valves, fittings, etc. inside pump house. ( pump house separate from control room as well as water storage tank to be constructed ) m1829.3 smoke detection system with all accessories and fittings m1829.1 hydrant system with complete u / g & o / g piping & accessories etc. ( all items ) out side the pump house. hydrant system shall cover the switchyard area, transformers, control room, stores etc. as per tender specification. m1829.5 complete hvw spray system with complete o / g & u / g piping and accessories etc. ( all items ) with all required materials and equipments out side the pump house for 160 mva, 2 nos, 220 / 132 / 33 kv power transformers as per tender specification. m1829.6 fire protection system 132kv, 80 mva, 3 ph t / f m1830 illumination system m1830.1 control room building: m1830.2 lighting yanel m1830.3 lighting yanel ( indoor ) type acy 1 as per tech. specification m1830.1 lighting yanel ( indoor ) type dcy as per tech. specification m1830.5 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1830.6 lighting fixture type f1 as per tech. specification m1830.7 lighting fixture type ff: as per tech. specification m1830.8 lighting fixture type if: as per tech. specification m1830.9 lighting fixture type fb: as per tech. specification m1830.10 lighting fixture type yf: as per tech. specification m1830.11 led type m1830.12 lighting fixture type f1 as per tech. specification ( blrb218 led+ 2 led tubes ) m1830.13 lighting fixture type ff: as per tech. specification ( bzbrsll gx 31w cw ) m1830.11 lighting fixture type if: as per tech. specification ( bzslo 18 w led ) m1830.15 lighting fixture type fb: as per tech. specification ( bicdo 10w led ) m1830.16 lighting fixture type yf: as per tech. specification ( brtfg 72w led ) m1830.17 5 / 15 a, 210v: indoor receptacles 3 pin type ( type ri ) m1830.18 15a, 210v: out door receptacles 2 pole, 3 pin type ( type ro ) m1830.19 63a, 115v : interlocked switch socket outdoor receptacles ( type ry ) m1830.20 switchboards m1830.21 modular switch board with 1 nos. 5amp. switches and 1 no. 5 / 15 amp. receptacles m1830.22 modular switchboard with 6 nos. 5amp. switches m1830.23 modular switchboard with 2 nos. 5amp. switches m1830.21 modular switchboard with 6 nos. 32 amp mcb m1830.25 modular switchboard with 1 no. 32 amp. mcb m1830.26 ceiling fans m1830.27 1100 mm sweep with electronic step regulator m1830.28 exhaust fans m1830.29 wall mounted fans 100 mm sweep m1830.30 conduits & wires m1830.31 heavy duty yvc conduits as of 20 / 25 / 32 mm size complete with all accessories for point wiring for light points, fans power points 5 / 15 amps. with 2.5 sq.mm / 1 mm2 / 6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire yvc insulated in green color including wiring for submains i.e. wiring from lighting panel to switch board. m1830.32 wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5 / 1.0 / 6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire ( green ) will be used for earthing inside conduits m1830.33 telephone sockets m1830.31 single socket outlet comprising rj 11 socket m1830.35 dual socket outlet comprising rj 15 socket m1830.36 junction boxes with 1 nos. of terminal blocks for indoor lighting excluding junction box supplied alongwith lighting fixture m1830.37 lighting transformer 10 kva, 115 / 115, 3 phase, 50 hz dry type as per tech. specification. m1830.38 lighting transformer 100 kva, 115 / 115, 3 phase, 50 hz dry type as per tech. specification. m1830.39 self supported aluminium ladder as per technical specification m1830.10 ffyh building m1830.11 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1830.12 lighting fixture type f1: as per tech. specification m1830.13 lighting fixture type if: as per tech. specification m1830.11 lighting fixture type fb: as per tech. specification m1830.15 lighting fixture type yf: as per tech. specification m1830.16 5 / 15 a, 210v: indoor receptacles 3 pin type ( type ri ) m1830.17 switchboards m1830.18 modular switch board with 1 nos. 5amp. switches and 1 no. 5 / 15 amp. receptacles m1830.19 modular switchboard with 6 nos. 5amp. switches m1830.50 modular switchboard with 2 nos. 5amp. switches m1830.51 ceiling fans m1830.52 1100 mm sweep with electronic step regulator m1830.53 exhaust fans m1830.51 wall mounted fans 100 mm sweep m1830.55 conduits & wires m1830.56 heavy duty yvc conduits as of 20 / 25 / 32 mm size complete with all accessories for point wiring for light points, fans power points 5 / 15 amps. with 2.5 sq.mm / 1 mm2 / 6.0 mm2 copper for circuit wiring and 1.5 mm2 copper earth wire yvc insulated in green color including wiring for submains i.e. wiring from lighting panel to switch board. m1830.57 wiring from lighting panel to switch boards, from switchboard to junction boxes for light points with 2.5 / 1.0 / 6.0 mm2 copper wire as per technical specification, complete in all respect. 1.5 mm2 copper wire ( green ) will be used for earthing inside conduits m1830.58 junction boxes with 1 nos of terminal blocks for indoor lighting excuding junction box supplied alongwith lighting fixtures. m1830.59 outdoor lighting ( switchyard and street lighting ) m1830.60 lighting panel m1830.61 lighting panel ( outdoor ) type acy 2 m1830.62 lighting panel ( outdoor ) type acy 3 m1830.63 lighting fixtures and receptacles ( including accessories / materials etc. as per requirement like junction box, cable / wires, flexible conduits ( if required ) from junction box to lighting fixtures, mounting arrangements ) m1830.61 lighting fixture type sf1: as per tech. specification m1830.65 lighting fixture type sf2: as per tech. specification m1830.66 lighting fixture type my: as per tech. specification m1830.67 lighting fixture type sc: as per tech. specification m1830.68 15a, 210v : outdoor receptacles 2 pole, 3 pin type ( type ro ) m1830.69 63a, 115v: interlocked switch socket outdoor receptacles ( type ry ) m1830.70 lighting poles type a1 m1830.71 lighting poles type e1 m1830.72 cart wheel mounted aluminium ladder as per tech. specification m1830.73 lighting cum lightning masts as per design m1830.71 erection of lighting pillar box in switchyard on foundation laid ( excluding pillar box ) . ( for 220kv 132kv ) m1831 erection of wave trap m1831.1 fixing of wavetrap on pedastal mounting insulator stack in 100kv m1831.2 fixing o f the wave trap on pedastal mounting insulator stack in 220kv m1831.3 fixing of the wave trap on suspension mounting including jumpering in 132kv m1832.1 erection of olte & mux ( optical line terminal equipment ) equivalent to ylcc pannel m1832.2.1 erection of fdy ( fibre distribution yanel in 100kv / 220kv / 132kv ss ( 12f ) m1832.2.2 erection of fdy ( fibre distribution yanel in 100kv / 220kv / 132kv ss ( 21f ) m1832.2.3 erection of fdy ( fibre distribution yanel in 100kv / 220kv / 132kv ss ( 18f ) m1832.3 erection of 16 / 16 eyax equipment in 100kv / 220kv / 132kv ss m1833 erection of rtu panel in 100kv / 220kv / 132kv ss m1831 erection of protection coupler equipment in 100kv / 220kv / 132kv ss m1835 laying of optical fibre approach cable in switch yards of 100kv, 220kv & 132kv ( including hardware ) m1836.1 check survey, peg marking the tower positions on ground, conforming to the approved profile and tower schedules using gps, total stations, digita theodolites etc.the rate is also applicable for re check survey if any done due to row problems m1836.2 conducting reconnoitery and preliminary survey along bee line with three alternative routes and furnishing report for selecting the best proposal for approval, including cost & conveyance of all materials, hire charges of equipment, tools and plant, preparation of drawings and reports, labour charges, complete for finished item of work as per the directions of engineer in charge at site. ( with theodolite / with gps equipment / with total station equipment ) . m1836.3 conducting detailed survey by taking the levels along the route to a corridor of 15 mtrs. width on either side of alignment, at every 20 mtrs. interval and wherever there is a steep increase / decrease in ground profile duly indicating the chainage between angle points, river crossings, railway crossing and major highway crossings and plotting the profiles and preparation of vicinity maps to the standard scales. the survey includes clearing of bushes, branches of tree, crops and shrubs wherever encountered for detailed survey for viewing, for fixing anchor towers and also taking levels etc. required for conducting detailed surveys. this work can be done with theodolite or with gps equipment or with total station equipment. this work involves the following items. m1836.3.1 tower schedules as per tower spotting requirements plotted on reproducible tracing of profile original with one extra copy shall ordinates. identification of wind zones, collection of hydraulic data be given . towers schedules should be submitted with gps co of rivers / drains from competent authority. m1836.3.2 taking earth resistivity at an interval of 1 km by electrical resistivity method ( 4 point method ) or by erm method. m1836.3.3 preparing of ptcc questionnaire, topo sheets extracts with marking of the proposed line. soil resistivity report, tower sketch, station single line diagram etc. ( 30 copies / sets ) up to 25km above 25km m1837 enumeration and numbering of trees, & marking on tree with white letters on yellow paint measuring girth and height of the trees and plotting in the profile. the trees enumerated shall be shown in profile on either side of centre line clearly, up to required corridor for 132kv line 27 metres & 220kv line 35 meters ) indicating name of tree, girth & height. separate tree schedule should be submitted along with the profile for arriving tree compensation amount. m1838 preparation of ground profiles for railway crossing, river crossing and ehv power line crossing separately wherever required. the above rates shall include cost and conveyance of all materials hire charges of equipment tools & plant, preparation of profile drawing, painting of trees, labour charges, preparation of report etc., complete for finished item of work as per instructions of engineer in charge. m1839 excavation of trial pits of standard dimensions of 1 mtr x 1 mtr. width upto 3 mtrs. depth at 1 km interval or wherever there is abnormal change in topography and taking observation of soil strata for classification of foundation and position of existing ground water table / depth of water in the existing open wells if any and back filling the trial pits after vetting by departmental officials. m1840 setting of stubs with stub setting template : erection of stubs, stub template, fixing of jacks for supporting template, allignment and levelling for exact location of stubs of stubsetting template, dismantling of template after completion of initial curing of c.c., movement of template from one location to other location ( a minimum lead of 1 km is adopted ) . m1841 erection of tower structures, including all types of extensions, nuts & bolts ..etc for transmission lines m1841.1 erection of tower structures, including all types of extensions except jc type towers ( stub template erection and dismantling are not to be included ) ( including 3 mtr., 6 mtr. , 9 mtr., & 12 mtr.extensions ) m1841.2 erection of all types of narrow based towers / multi circuit tower structures / narrow based multi circuit towers structures, including all types of extensions except jc type towers ( stub template erection and dismantling are not to be included ) ( including 3 mtr., 6 mtr. , 9 mtr., & 12 mtr. extensions ) m1841.3 erection of all types of jc / special type tower structures, including all to be included ) ( including 0 based, extended and truncated ) m1841.4 erection of pole / structure for 220 / 132 kv cable termination types of extensions ( stub template erection and dismantling are not m1842 stringing of power conductor: hoisting of tension insulators and suspension insulators, paving out the conductor, rough sagging, jointing, tensioning, clipping and fixing of preformed armour rods and vibration dampers. measuring ground clearances wherever necessary.which excludes the works involved in the crossing of lt, 11kv & 33kv power lines viz dismantling and restringing of conductor including earth wire / opgw m1842.1 stringing 220kv zebra m1842.1.1 3nos. zebra conductors m1842.1.2 6nos. zebra conductors m1842.1.3 stringing of 220 kv m / c transmission line with 12 phase acsr zebra conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. stringing 220kv twin moose m1842.1.4 stringing of 220 kv d / c transmission line with 06 phase acsr twin moose conductor ( total 12 nos. of conductor ) ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1842.1.5 stringing of 220 kv m / c transmission line with 12 phase acsr twin moose conductor ( total 24 nos. of conductor ) ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. de stringing 220kv zebra m1842.1.6 de stringing of 220 kv s / c transmission line with 03 phase acsr zebra conductor ( without opgw / eartwire ) complete in all respect including transportation and handing over the dismantled materials to the jusnl stores. m1842.1.7 de stringing of 220 kv d / c transmission line with 06 phase acsr zebra conductor ( without opgw / eartwire ) complete in all respect including transportation and handing over the dismantled materials to the jusnl stores. m1842.2 stringing 132kv panther m1842.2.1 2nos. panther conductors m1842.2.2 3nos. panther conductors m1842.2.3 2nd circuit stringing ( without 1st circuit live ) of 132 kv s / c dcss transmission line with 03 phase acsr panther conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1842.2.4 2nd circuit stringing ( with 1st circuit live ) of 132 kv s / c dcss transmission line with 03 phase acsr panther conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1842.2.5 6nos. panther conductors m1842.2.6 stringing of 132 kv m / c transmission line with 12 phase acsr panther conductor complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. stringing 132kv single moose m1842.2.7 stringing of 132 kv d / c transmission line with 06 phase acsr moose conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. de stringing 132kv panther m1842.2.8 de stringing of 132 kv s / c transmission line with 03 phase panther conductor ( without opgw / eartwire ) complete in all respect including transportation and handing over the dismantled materials to the jusnl stores. m1842.2.9 dismantling & re stringing of 33 kv conductor ( all types of conductors ) for crossing of 33 kv line during stringing of eht lines. m1842.2.10 dismantling & re stringing of 11 kv conductor ( all types of conductors ) for crossing of 11 kv line during stringing of eht lines m1842.2.11 dismantling & re stringing of lt conductor / cables for crossing of lt line ( all types ) during stringing of eht lines m1842.3 stringing 400kv m1842.3.1 3nos. moose conductors m1842.3.2 6nos. moose conductors m1842.3.3 6 nos. twin moose conductors m1842.3.4 6 nos. quad moose conductors m1843 stringing of htls power conductor using tension puller machine: hoisting of tension insulators and suspension insulators, paving out the conductor, rough sagging, jointing, tensioning, clipping and fixing of preformed armour rods and vibration dampers. measuring ground clearances wherever necessary. which excludes the works involved in the crossing of lt, 11kv & 33kv power lines viz dismantling and restringing of conductor. m1843.1 stringing of 132 kv d / c transmission line with 06 phase htls conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1843.2 reconductoring of 132 kv s / c transmission line with 03 phase htls conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1843.3 reconductoring of 132 kv d / c transmission line with 06 phase htls conductor ( without opgw / eartwire ) complete with all works including stringing of conductor, fitting of hardwares, hoisting of insulators etc. m1844 stringing / de stringing earthwire m1844.1 stringing of earthwire: fixing hardware, paving out earth wire, jointing, tensioning, stringing and clamping of 7 / 3.15 mm high tensile galvanised steel wire. m1844.2 de stringing of earthwire only from 132 kv / 220 kv s / c or d / c transmission line complete in all respect including transportation and handing over the dismantled materials to the jusnl stores. m1845 opgw & communication m1845.1 installation / stringing of 24 f opgw cable complete with all works excluding hardware assemblies and joint boxes ( rate per route km ) m1845.2 installation of hardware assembly m1845.3 installation of 24 f joint box m1845.4 installation, testing & commissioning of complete opgw and communication equipments de stringing of opgw & communication m1845.5 un installation / de stringing of 24 f opgw cable from 132 kv / 220 kv s / c or d / c transmission line complete in all respect including transportation and handing over the dismantled materials to the jusnl stores. m1846 tower earthing m1846.1 earthing of towers including cost of excavation, back filling, including cost of 25 mm dia 2.5 mm thick, class cg.i. pipe of 3.00 mtrs length with 50x6 mm g.i. flat 4.05 mtrs long, bh coke, salt etc., and measuring tower footing resistance. m1846.2 slant earthing of towers including cost of excavation, back filling, including cost of 25 mm dia 2.5 mm thick, class cg.i. pipe of 3.00 mtrs length, with 50x6mm g.i. flat of 4.05 meters, bh coke, salt etc., and measuring tower footing resistance. m1846.3 earthing of towers including cost of excavation, back filling, including cost of 25 mm dia 2.5 mm thick, class cg.i. pipe of 3.00 mtrs length, bh coke, salt etc., and measuring tower footing resistance. ( without gi flat ) for counter poise earthing. m1846.4 counterpoise earthing including clamping devices and terminal lugs, but excluding cost of steel wire. m1847.1 half round welding of g.i.bolts and nuts of towers in the section between ground level & upto bottom x arm level including all bolts connecting the bracings at the bottom x arm level and painting the welded portion with one coat of zinc rich paint. m1847.2 half round welding of g.i.bolts and nuts of towers in the section between ground level & upto bottom x arm level including all bolts connecting the bracings at the bottom x arm level and painting the welded portion with one coat of zinc rich paint for jc type towers m1848 foundation m1848.1 excavation of soil for transmission line m1848.1.1 excavation in dry soil m1848.1.2 excavation in wet soil m1848.1.3 excavation in dry fissured rock soil m1848.1.4 excavation in wet fissured rock soil m1848.1.5 excavation in hard rock soil m1848.2.1 concreting 1:1.5:3 ( m20 ) m1848.2.2 concreting 1:3:6 ( m10 ) m1848.3 providing reinforcement steel m1848.4 benching m1848.5 revetment m1848.5.1 random rubble stone masonary including excavation m1848.5.2 backfilling and levelling of volumes enclosed in revetment m1848.5.3 m 15 ( 1:2:4 ) concrete for top seal cover of revetment m1849 soil investigation in all kinds of soil except hr & fr m1850 tower accessories installation m1850.1 danger board m1850.2 number plate m1850.3 phase plate ( set of three ) m1850.4 circuit plate ( set of two ) m1850.5 anticlimbing device m1850.6 bird guard ( set of three ) m1851 proto assembly & type testing m1851.1 proto assembly charges for all types of 132 kv towers ( suitable for acsr panther / htls conductor ) m1851.2 proto assembly charges for all types of 132 kv towers ( suitable for single acsr moose conductor ) m1851.3 proto assembly charges for all types of 220 kv towers ( suitable for acsr zebra conductor ) m1851.4 proto assembly charges for all types of 220 kvtowers ( suitable for twin acsr moose conductor ) m1851.5 type test charges for acsr panther conductor m1851.6 type test charges for acsr zebra conductor m1851.7 type test charges for acsr moose conductor m1851.8 type test charges for htls conductor m1851.9 type test charges for long rod polymer insulator m1851.10 type test charges for hardware fittings m1851.11 type test charges for conductor accessories m1852 erection of 132 kv xlpe cables m1852.1 cable route survey, preparation of cable route profile, route alingment, drawings etc. complete in all respect. m1852.2 laying of 132 kv xlpe ug cable ( 1cx 630 sqmm / 800 sqmm ) including construction / excavation of buried cable trench including backfilling, warnig tape, route marker etc. complete in all respect. m1852.3 installation of 132 kv termination kit with scaffolding arrangement etc. complete in all respect. m1852.4 installation of link box without sheath voltage limiters ( svl ) ( surge arrestors ) along with bonding cable m1852.5 installation of link box with sheath voltage limiters ( svl ) ( surge arrestors ) along with bonding cable m1852.6 laying / installation of earth continuity cu. cable of suitable size ( 1cx 240 sqmm / equivalent or as suitable ) along with necessary connection with both end. m1852.7 construction of earth pit including supply of gi pipes etc. m1852.8 testing & commissioning meggering & phase squence etc. m1852.9 laying and terminations of 11kv, xlpe 1000 sqmm cable m1852.10 laying of 33 kv 400 sq.mm xlpe cable m1852.11 termination of 400 sq.mm xlpe cable m1853.1 ( a ) .providing of vibration dampers ( for 220 kv & 132 kv lines ) ( excluding material & transportation cost ) m1853.2 ( b ) . providing of spacer damper for 400 kv twin moose lines ( excluding material & transportation cost ) m1854 painting of towers with two coats of aluminum paint using aluminum paint 1st grade containing 306 kg of aluminum paste for 18 liters of thinner 1st coat is to be applied before erection of towers and 2nd coat after stringing and half round welding including cost of paint, cost of brushes, labour charges etc., complete. m1854.1 first coat of 1st grade aluminum paint duly scratching and cleaning of towers including labour charges, cost of paint, brushes etc. m1854.2 labour charges for painting including scratching and cleaning of towers of 1st coat of alluminum with out cost of paint & brushes. m1854.3 ( * ) second coat of 1st grade aluminium paint duly scratching and cleaning of towers including labour charges, cost of pint, brushes, etc. m1854.4 ( * ) labour charges for painting including scratching and cleaning of towers of 2nd coat of aluminum with out cost of paint & brushes. ( * ) : the requirement of 2nd coat is to be justified by the concerned divisional engineer / executive engineer before execution of the work. m1854.5 painting of towers with single coat of red oxide paint of 1st grade, including scratching and cleaning of towers. m1854.6 one coat of 1st grade red oxide paint including labour charges for scratching and cleaning of towers including cost of paint, brushes etc. m1854.7 labour charges for painting of towers including scratching and cleaning of towers without cost of paint & brushes. m1854.8 painting the welded portion of gi bolts and nuts of towers in the section ground level and up to xarm level including all bolts connecting the bracings at the bottom x arm level with one coat of zinc rich paint including cost of paing. m1855 providing of arcing horns m1855.1 providing of arcing horns for 132 kv line on both tower side and line side i.e. two per string ( excluding material & m1855.2 providing of arcing horns for 132 kv line ( excluding material & transportation cost ) ( without lefty & pullies ) m1855.3 providing of arcing horns for 220 kv line on both tower side and line side i.e. two per string ( excluding material & transportation cost ) ( with lefty & pullies ) m1855.4 providing of arcing horns for 220 kv line ( excluding material & transportation cost ) ( without lefty & pullies ) m1855.5 fixing of earth bonds for existing transmission line towers m1856.1 providing of missing angles / replacement of rusted angles on the existing towers departmentally ( including transporaton charges & excluding cost of tower parts, bolts & nuts ) m1856.2 fabrication of tower members at site m1857 replacement of insulators m1857.1 replacement of insulators at suspension tower of 132 kv line ( excluding material & transportation cost ) m1857.2 replacement of insulators at tension tower of 132 kv line ( excluding material & transportation cost ) m1857.3 replacement of insulators at suspension tower of 220 kv line ( excluding material & transportation cost ) m1857.4 replacement of insulators at tension tower of 220 kv line ( excluding material & transportation cost ) m1857.5 replacement of 132kv line single suspension insulator string with double suspension insulator strings ( excluding material & transportation cost ) m1857.6 replacement of 132 kv line single tension insulator string with double tension insulator strings ( excluding material & transportation cost ) m1857.7 replacement of 220kv line single suspension insulator string with double suspension insulator strings ( excluding material & transportation cost ) m1857.8 replacement of 220 kv line single tension insulator string with double tension insulator strings ( excluding material & transportation cost ) m1857.9 replacement of insulators at suspension tower of 400kv line ( excluding material & transportation cost ) m1857.10 replacement of insulators at tension tower of 400kv line ( excluding material & transportation cost m1858 re stringing of power conductor on the existing lines ( for correction of sag ) including fixing of tension insulators / suspension insulators, hardware and accessories, rough sagging, jointing, tensioning, clipping and fixing of performed armour rods and vibration dampers, measuring ground clearances wherever necessary. which includes the works involved in the crossing of lt, 11 kv & 33kv power lines viz dismantling and restringing of conductor. m1858.1 3nos. zebra conductors m1858.2 6nos. zebra conductors m1858.3 2nos. panther conductors m1858.4 3nos. panther conductors m1858.5 6nos. panther conductors m1858.6 2nos. moose conductors m1858.7 3nos. moose conductors m1858.8 6nos. moose conductors m1858.9 3nos. bear conductors m1858.10 6nos. bear conductors m1858.11 3nos. dog conductors m1858.12 6nos. dog conductors m1859 opening / restoration closing of jumper in lines m1859.1 tightening of jumper of transmission tower m1859.2 nut bolts tightening of 220 kv towers m1859.3 nut bolts tightening of 132 kv towers m1859.4 tack welding of the 220 kv towers m1859.5 tack welding of the 132 kv towers m1859.6 minor repairing of conductor with repair sleeve m1859.7 repairing of broken conductor m1859.8 lowering / uploading of single conductor m1859.9 dismantling of tower during tower collapse including conductor m1859.10 erection of tower m1859.11 repairing of cross arm m1859.12 repairing of stub m1860 mobilization / demobilization of labour gang for ers works m1861.1 rate for ers installation ( erection, jointing, jumpering ) per set complete in all respect. m1861.2 rate for ers dismantling includng conductor lowering per set complete in all respect. m1862 circuit breaker including cable termination m1862.1 220kv sf6 circuit breaker including cable termination m1862.2 132kv sf6 circuit breaker including cable termination m1862.3 33kv vacuum circuit breaker including cable termination m1863 current transformer including cable termination m1863.1 220kv current transformer including cable termination m1863.2 132kv current transformer including cable termination m1863.3 33kv current transformer including cable termination m1864 isolator including cable termination m1864.1 220kv ll isolator including cable termination m1864.2 132kv ll isolator including cable termination m1864.3 33kv ll isolator including cable termination m1865 la / sa m1865.1 220kv la / sa m1865.2 132kv la / sa m1865.3 33kv la / sa m1866 cvt / pt m1866.1 erection, testing and commissioning of 220 kv cvt / pt m1866.2 erection, testing and commissioning of 132 kv cvt / pt m1866.3 erection, testing and commissioning of 33 kv pt m1867.1 jumper in gss m1867.2 replacement of bus bar 220 / 132 / 33kv m1867.3 replacement of bushing / pole of 33kv vcb m1867.4 replacement of bushing / pole of 132kv cb m1868 laying of control cable m1868.1 2c x 2.5sq.mm to 4c x 2.5sq.mm m1868.2 10c x 2.5sq.mm to 18c x 6sq.mm and 10c x 6 mm2 m1869 erection, testing and commissioning of 132 kv transformers control & relay panel. m1870 erection of 33 kv post insulator m1871 erection, testing and commissioning of 33 / 0.4kv, 315 kva transformer ( sst ) . m1872.1 dismantling of sub station structures m1872.2 dismantling of cables. m1873 improvement of earthing of sub station m1874.1 spray painting of power transformers m1874.2 filtration of transformer oil, if m / c supplied by firm m1874.3 filtration of transformer oil, if m / c is supplied by jusnl ( 25% deduction ) m1874.4 rate for replacement of gasket of the transformer along with supply of gasket of : m1874.4.1 a ) radiator m1874.4.2 b ) hv bushing m1874.4.3 c ) lv bushing m1874.4.4 d ) hv / lv neutral bushing m1874.4.5 e ) tertiary bushing m1874.4.6 f ) conservator tank m1874.4.7 g ) oil level guage m1874.4.8 h ) silica gel m1874.4.9 i ) replacement of gasket of door of marshalling box & oltc control cable m1874.4.10 j ) inspection cover, manhole cover, valves, connecting pipes, tightening & terminal arrangement of bucholz relay, oti, wti m1875 clamps & connectors m1875.1 supply of 33 kv male contact of isolator 800 a m1875.2 supply of 33 kv male contact of isolator 1250 a m1875.3 supply of 33 kv female contact of isolator 1250 a m1875.4 supply of 132 kv female contact of isolator 1250 a m1875.5 supply of 220 kv female contact of isolator 1600 a m1875.6 copper terminal plate for 132 kv female contact m1875.7 pg clamp for moose to moose m1875.8 t connector for moose to moose m1875.9 palm connector for moose to moose m1875.10 pg clamp for zebra to zebra m1875.11 t connector for zebra to zebra m1875.12 palm connector for zebra to zebra m1875.13 pg clamp for panther to panther m1875.14 t connector for panther to panther m1875.15 palm connector for panther to panther m1875.16 t connector for zebra to zebra m1875.17 t connector for moose to panther m1875.18 t connector for moose to dog m1875.19 t connector for zebra to dog m1875.20 t connector for zebra to moose m1875.21 pg clamp for zebra to moose m1875.22 pg clamp for moose to wolf m1875.23 pg clamp for moose to wolf ( horizontal ) m1875.24 220 kv ct connector for zebra conductor with bronze mounting m1875.25 132 kv ct connector for zebra conductor with bronze mounting m1875.26 33 kv ct connector for moose conductor with bronze mounting m1875.27 33 kv ct connector for moose conductor t type with bronze mounting m1875.28 mid span joint for panther m1875.29 mid span joint for zebra m1875.30 mid span joint for earth wire m1875.31 suspension clamp for earth wire m1875.32 tension clamp for earth wire m1875.33 felx. copper bond for earth wire m1876 tripping coil m1876.1 33 kv tripping coil ( with flange ) m1876.2 132 kv tripping coil ( with flange ) m1876.3 33 kv closing coil ( with flange ) m1876.4 132 kv closing coil ( with flange ) m1877 supply of silica gel m1878 sf 6 gas m1878.1 ( a ) 52 kg gas cylinder m1878.2 ( b ) 26 kg gas cylinder a. loading / unloading of materials from departmental / private vehicles in to the stores yard and stacking and vice versa m1879.1 cement m1879.2 all other materials m1879.3 steel m1879.4 tower parts m1879.5 rs joists and rail poles and ms sheets pf various sizes. m1879.6 cable / conductor drums ( for loading / un loading ) m1879.7 panther acsr m1879.8 zebra acsr m1879.9 moose acsr m1879.10 moose acsr ( huge drums of 1.75km and above ) m1879.11 earth wire m1879.12 control cables up to 6 core m1879.13 control cables above 6 core m1879.14 3 1 / 2 core ltac cable drum ( up to 500 meters ) . m1879.15 3 1 / 2 core ltac cable drum ( above 500 meters ) . m1879.16 other materials received in cases. m1879.17 case weighing not more than 100kgs. m1879.18 case weighing from101kgs to 500kgs. m1879.19 case containg fragile items and weighing more than 501kgs and up to 1mt m1879.20 for ltac panel m1879.21 70kn normal disc insulator m1879.22 120kn normal disc insulator m1879.23 160kn normal disc insulator m1879.24 70kn anti fog disc insulator m1879.25 120kn anti fog disc insulator m1879.26 160kn anti fog disc insulator m1879.27 loading / un loading and stacking charges for 70kn m1879.28 132kv m1879.29 220kv m1879.30 loading / un loading and stacking charges for 120kn / 160kn src insulators for 400kv. m1879.31 cases containing control & relay panels m1879.32 33kv m1879.33 132kv and 220kv m1879.34 cases containing cts, pts, cvts m1879.35 11kv to 33kv rating m1879.36 above 33kv and up to 132kv m1879.37 220kv rating m1879.38 cases containing las m1879.39 33kv m1879.40 132kv m1879.41 220kv m1879.42 loading / un loading of m1879.43 33kv breaker m1879.44 132kv cb m1879.45 220kv sf6 cb m1879.46 station transformer ( 100kva ) m1879.47 station transformer ( 250kva ) m1879.48 220v 80ah battery ( conventional ) ( lead acid ) m1879.49 220v 80ah battery ( vrla ) ( maintenance free ) m1879.50 220v 200ah battery ( conventional ) ( lead acid ) m1879.51 220v 400ah battery m1879.52 220v battery charger with dc distribution board m1879.53 dcdb for battery charger. m1879.54 132kv hardware single m1879.55 132 kv hardware double m1879.56 220 kv hardware single m1879.57 220 kv hardware double m1879.58 220 kv isolators, without insulators including machanism box m1879.59 220kv solid core insulators m1879.60 132 kv isolators ( without soild core insulators ) m1879.61 132kv solid core insulators m1879.62 33 kv isolators ( without soild core insulators ) m1879.63 33kv solid core insulators m1879.64 vibration dampers, mid span compression joints, repair sleeves, clamps & connectors m1879.65 capacitor banks m1879.66 5 mvar m1879.67 neutral c.t. m1879.68 scrap items like ms scrap, gi scrap, ferrous scrap etc, . m1879.69 scrap items like conductor scrap, earth wire scrap, etc, . m1879.70 bolts & nuts weighing 50 kgs bags including springs washers, flat washers. m1879.71 3 1 / 2 core ltac cable bits ( loose ) by measuring and load / unload ( up to 500 meters, limited to rs.142 per bit ( maximum ) m1879.72 cable bits ( loose ) up to 6 core by measuring and load / un load. ( up to 500 meters, limited to rs.106 per bit ( maximum ) m1879.73 cable bits ( loose ) above 6 core by measuring and load / un load. ( up to 500 meters, limited to rs.142 per bit ( maximum ) m1879.74 copper scrap m1879.75 battery scrap m1879.76 capacitor units scrap m1879.77 33kv breaker limb m1879.78 132kv breaker limb m1879.79 220kv breaker limb m1879.80 tyres scrap of all sizes m1879.81 empty oil drums m1879.82 full oil drums m1879.83 220v, 200ah battery ( vrla ) ( maintenance free ) m1879.84 220kv bushing m1879.85 132kv bushing m1879.86 33kv bushing m1880.1 tower parts counting on part wise and restocking at stores yard ( for stock verification purpose ) m1880.2 labour charges for weighing and restocking of gi tower parts or bolts & nuts, washers ( for stock verification purpose ) m1880.3 labour charges for loading and unloading of acsr, aaa conductor & earth wire bits for weighiment ( for stock verification purpose ) . m1880.4 counting and restocking of hardware ( iron parts, al jumper cones, al tensition cones, pa rods, arcing horns, al grippers etc ) ( for stock verification purpose ) note: if loading / un loading is done with crane, 1 / 3 rd charges are to be paid towards labour charges and remaining towards crane hire charges.example: loading charges of 100 kva station transformer is rs. 382 / and in case using a crane then labour charges would be rs.127.33 / & crane hire charges would be rs.255.67 / b. loading and un loading and counting at stores for check measuring and stock verification m1880.5 counting and restocking of 220kv & 132kv line accessories like dampers, msc joints, repair sleeves, pa rods, d shackles links, earthing sets, hangers, counter poise earthing clamps etc ( for stock verification purpose ) m1880.6 counting and restocking of insulators of various capacities ( for stock verification purpose ) m1880.7 loading of assorted tower parts from different places by observing part wise and loading in to lorry at stores m1880.8 for opening and repacking of packing of panels for check measuring purpose m1880.9 for opening and repacking of packing of breakers for check measuring purpose m1880.10 220 kv m1880.11 132 kv m1880.12 33 kv m1880.13 for opening and repacking of packing of fragile materials, and small packages like wooden, cartoon boxes etc., for check measuring purposes. m1881.1 crane hire charges for 2 to 8 tonne capacity crane m1881.2 for ist hour m1881.3 for every hour or part thereof after ist hour for 8 to 20 tonne capacity crane m1881.4 for ist hour m1881.5 for every hour or part thereof after ist hour for above 20 tonne capacity crane m1881.6 for ist hour m1881.7 for every hour or part thereof after ist hour m1882.1 m1882.2 sparing of departmental vehicle ( lorry ) to the contractor is under emergency only. when departmental lorry is engaged to the contractor on a particular day an amount per day or part there of should be recovered for a total km run up to 100km on that day plus for every additional km rate, which ever is higher. the run to be worked out taking initial reading at starting point and closing reading after returing the same starting point duly c. crane hire charges: ( for departmental works at the premises ) d. sparing of departmental vehicle to the contractor m1883 loading / unloading of t&p such as wooden sleepers, winch jacks, packing pieces etc., required for handling the power transformers. m1883.1 up to 31.5 mva transformers, one load of wooden sleepers and another load of t&p such as chain pulley block and rail poles etc ( maximum two loads ) m1883.2 for above 31.5 mva and up to 100 mva transformers, two loads of wooden sleepers and another load of t&p such as chain pulley block, winch and rail poles etc ( maximum three loads ) m1883.3 for the above 100 mva and up to 160 mva transformers, three loads of wooden sleepers and another load of t&p such as winch machine and rail poles etc ( maximum four loads ) m1883.4 loading / unloading of fragile material such as lv bushing / neutral bushing for 132 kv transformer m1883.4.1 loading m1883.4.2 unloading 132kv bushings m1883.4.3 loading m1883.4.4 unloading 220kv bushings m1883.4.5 loading m1883.4.6 unloading m1883.5 loading / unloading of accessories of transformer including raidator, pipe line, fcc & rtcc panels, conservator tank, turrets la set frames and oil barrels a frame and header etc., ( for 50mva and above 50 mva ptrs without oil barrels ) m1884 dragging of power transformer main tank duly arranging wooden sleeper platform providing packing pieces, jacking up the transformer, insertion of wooden sleeper, rail poles arrangement of pullies, steel ropes positioning of winch and anchoring of winch. m1884.1 transformers upto 16 mva capacity m1884.1.1 up to 10 mtrs. m1884.1.2 over and above 10 mtrs. m1884.2 transformers above 16mva and upto 31.5 mva capacity m1884.2.1 up to 10 mtrs. m1884.2.2 over and above 10 mtrs. m1884.3 transformers above 31.5mva and upto 50 mva capacity m1884.3.1 up to 10 mtrs. m1884.3.2 over and above 10 mtrs. m1884.4 transformers above 50mva and upto 100 mva capacity m1884.4.1 up to 10 mtrs. m1884.4.2 over and above 10 mtrs. m1884.5 transformers above 100mva and upto 160 mva capacity m1884.5.1 up to 10 mtrs. m1884.5.2 over and above 10 mtrs. m1884.6 turning the transformer through 90 degrees including making arrangements as above. m1884.6.1 transformers upto 16 mva capacity m1884.6.2 transformers above 16mva and upto 31.5 mva capacity m1884.6.3 transformers above 31.5mva and upto 50 mva capacity m1884.6.4 transformers above 50mva and upto 100 mva capacity m1884.6.5 transformers above 100mva and upto 160 mva capacity m1884.7 turning the transformer through 180 degrees including making arrangements as above. m1884.7.1 transformers upto 16 mva capacity m1884.7.2 transformers above 16mva and upto 31.5 mva capacity m1884.7.3 transformers above 31.5mva and upto 50 mva capacity m1884.7.4 transformers above 50mva and upto 100 mva capacity note: if loading / un loading is done with crane, 1 / 3rd charges are to be paid towards labour charges and remaining a. handling as job work by department m1884.7.5 transformers above 100mva and upto 160 mva capacity m1884.7.6 anchoring of transformer including excavation of trench of 4 x 1x0. 5 mtrs for anchoring and burying 2 nos. sleepers in it and removing the same after work is completed. m1884.7.7 movement of 10 mt winch for anchoring. m1884.8 lifting / lowering the transformer main tank to the required height of one sleeper using jacks and wooden sleepers packing pieces for loading onto / from the truck m1884.8.1 transformers upto 16 mva capacity m1884.8.2 transformers above 16mva and upto 31.5 mva capacity m1884.8.3 transformers above 31.5mva and upto 50 mva capacity m1884.8.4 transformers above 50mva and upto 100 mva capacity m1884.8.5 transformers above 100mva and upto 160 mva capacity m1884.9 pulling the transformer from platform to the truck for loading / from truck to the platform for unloading m1884.9.1 transformers upto 16 mva capacity m1884.9.2 transformers above 16mva and upto 31.5 mva capacity m1884.9.3 transformers above 31.5mva and upto 50 mva capacity m1884.9.4 transformers above 50mva and upto 100 mva capacity m1884.9.5 transformers above 100mva and upto 160 mva capacity m1884.10 fixing of transformer wheels to main tank including alignment of transformer etc., m1884.10.1 transformers upto 16 mva capacity m1884.10.2 transformers above 16mva and upto 31.5 mva capacity m1884.10.3 transformers above 31.5mva and upto 50 mva capacity m1884.10.4 transformers above 50mva and upto 100 mva capacity m1884.10.5 transformers above 100mva and upto 160 mva capacity m1884.10.6 arranging gas cutter equipment at site including operator and helper to remove anchoring of transformer main tank on truck for loading and unloading ( including cost of gas ) m1884.11 removal of steel rope and turn buckles of transformer main tank on truck. m1884.11.1 up to 100mva capacity m1884.11.2 above 100mva and up to 160mva capacity m1884.12 tieing the transformer main tank on to the truck with steel rope and turn buckles m1884.12.1 up to 100mva capacity m1884.12.2 above 100mva and up to 160mva capacity m1884.13 assisting for lifting of overhead live lines, while transporting of transformers by truck. m1884.13.1 up to 100mva capacity m1884.13.2 above 100mva and up to 160mva capacity m1885 transportation of power transformer m1886.1 opening of crates and keep ready for erection of accessories of transformers m1886.1.1 transformers upto 16 mva capacity m1886.1.2 transformers above 16mva and upto 31.5 mva capacity m1886.1.3 transformers above 31.5mva and upto 50 mva capacity m1886.1.4 transformers above 50mva and upto 100 mva capacity m1886.1.5 transformers above 100mva and upto 160 mva capacity m1886.2 shifting, loading dragging of accessories of transformers like radiator, conservator tank, pipe line, fans, headers, dm box, fcc, oil barrels etc., from place of storage to work spot and vice versa of transformers. ( for 50mva and above 50 mva ptrs without oil barrels ) m1886.2.1 transformers upto 31.5 mva capacity m1886.2.2 transformers above 31.5mva and upto 100 mva capacity m1886.2.3 transformers above 100mva and upto 160 mva capacity m1886.2.4 transportation of oil barrels from unloading place to the filter machine in the substation. m1886.3 erection of radiators to the transformers including headers erection of power transformers as job work by department m1886.3.1 transformers upto 16 mva capacity m1886.3.2 transformers above 16mva and upto 31.5 mva capacity m1886.3.3 transformers above 31.5mva and upto 50 mva capacity m1886.3.4 transformers above 50mva and upto 100 mva capacity m1886.3.5 transformers above 100mva and upto 160 mva capacity m1886.4 erection of main conservator tank. m1886.4.1 transformers upto 16 mva capacity m1886.4.2 transformers above 16mva and upto 31.5 mva capacity m1886.4.3 transformers above 31.5mva and upto 50 mva capacity m1886.4.4 transformers above 50mva and upto 100 mva capacity m1886.4.5 transformers above 100mva and upto 160 mva capacity m1886.4.6 pronal bag testing and commissioning m1886.4.7 hiring of compressor m1886.4.8 dry nitrogen cylinder ( in case, dry nitrogen cylinder is used for commissioning of air cell instead of air compressor ) , excluding transportation cost. m1886.5 erection of transformer bushing m1886.5.1 33 kv neutral and teritary bushings m1886.5.2 132 kv bushings up to 100mva. m1886.5.3 132 kv bushings for above 100mva and up to 160mva m1886.5.4 220 kv bushings up to 100mva m1886.5.5 220 kv bushings for above 100mva and up to 160mva m1886.5.6 220kv 3 nos. erection of turrets up to 100mva m1886.5.7 220kv 3 nos. erection of turrets for above 100mva and up to 160mva m1886.5.8 132kv 3 nos. erection of turrets up to 100mva m1886.5.9 132kv 3 nos. erection of turrets for above 100mva and up to 160mva m1886.5.10 erection of air blowers ( cooling fans ) including frames and control cubical etc., ( for each transformer ) m1886.5.11 erection of la frames ( hv & lv side ) m1886.6 erection of driving mechanism box, bevel gear of oltc m1886.6.1 for below 100mva.. m1886.6.2 for 100mva and above m1886.7 erection of oltc conservator tank with stand m1886.7.1 up to 100mva. m1886.7.2 above 100mva and upto 160mva m1886.8 erection of pipe line m1886.8.1 transformers upto 31.5 mva capacity m1886.8.2 transformers above 31.5mva and upto 50 mva capacity m1886.8.3 transformers above 50mva and upto 100 mva capacity m1886.8.4 transformers above 100mva and upto 160 mva capacity m1886.9 erection of thermometer, pressure relief valve and vent pipe etc., m1886.9.1 for below 100mva.. m1886.9.2 for 100mva and above m1886.10 erection of detachable oltc including connecting internal jumper with oltc tank. m1886.10.1 transformers upto 31.5 mva capacity m1886.10.2 transformers above 31.5mva and upto 100 mva capacity m1886.10.3 transformers above 100mva and upto 160 mva capacity m1886.11 erection of separate, cooler bay including a frame header pipes and bends of transformers m1886.11.1 for below 100mva.. m1886.11.2 for 100mva and above m1886.12 removal of old worn out gaskets and replacement with new gaskets including cutting, pasting gasket with all accessories including cost of adhesives. excl. top cover m1886.12.1 transformers upto 16 mva capacity m1886.12.2 transformers 31.5mva and 100 mva capacity job m1886.12.3 transformers 100 mva and upto 160 mva capacity m1886.13 removal of old worn out gaskets and replacement with new gaskets including cutting, pasting of gasket with all accessories including cost of adhesives. for top cover. the following rates are exclusive of crane hire charges which are payable at actuals. m1886.13.1 transformers upto 16 mva capacity m1886.13.2 transformers 31.5mva and 100 mva capacity job m1886.13.3 transformers 100 mva and upto 160 mva capacity m1886.14 erection of supporting insulators and earth flat for hv & lv neutrals / tertiary. m1887.1 loading / unloading of 2kl oil filter. m1887.2 laying of l.t.cable from ac supply point to filter connecting pipes etc, from filter to transformer and back to filter and vice versa. m1887.3 loading / unloading of full transformer oil barrels. m1887.4 loading / unloading of oil drums. m1887.5 oil topping for transformer through oil filter m1887.5.1 transformers upto 31.5 mva capacity transformer already filled with oil m1887.5.2 transformers above 31.5mva and upto 50 mva capacity when the transformer is received with transformer oil c. oil filteration of transformers as job work m1889 rtu base equipment comprising panels, racks, sub racks, power supply modules, communication modules, interfacing equipment, required converters & all other required items / accessories including complete wiring for all modules for locations mentioned in appendix a m1889.1 splitter for rtu communication m1889.2 modems m1889.3 weather sensor m1889.4 oltc transducer m1889.5 heavy duty relay m1889.6 contact multiplying relay ( cmrs ) m1889.7 multi function transducers ( mfts ) m1889.8 supervisory interface cubicles ( sic ) panel for mounting mfts, relays etc m1889.9 time synchronisation equipment without display m1889.10 cpu m1889.11 analog input module m1889.12 digital input module m1889.13 digital output module m1889.14 ldms system alongwith software m1889.15 furniture for ldms system ( one table and one chair ) m1889.16 inverter test equipment for rtu m1889.17 master station cum rtu simulator & protocol analyser software tool m1889.18 laptop pc for above software tools alongwith interfacing hardware cables for each c&r panels connection with rtu m1889.19 cat 6 for mft m1889.20 2.5 mm / 14c di hv side ( copper ) m1889.21 2.5 mm / 7c di lv side ( copper ) m1889.22 2.5 mm / 4c for do ( trip / close ) ( copper ) m1889.23 conduit gprs based modem for data connectivity from rtu to sldc for control centre location m1889.24 industrial grade 16 port serial server, 230v ac power input ( 19 rack mount type ) m1889.25 ethernet module m1889.26 6u rack for remote location ( grid sub stations ) m1889.27 rtu site equipments: industrial grade gprs based cellular server, one rs232 port, one no. 10 / 100 ethernet port, ip 30 protected case support dtu functions, routing firewall m1889.28 48v dc to 12v dc supply m1890 software m1890.1 scada m1890.2 iccp communication m1890.3 cfe communication m1890.4 network management system m1890.5 information storage & retrivel ( isr ) m1890.6 isr software m1890.7 data historian software m1890.8 software for san and nas m1890.9 report development and generation software m1890.10 ems functions m1890.11 power system applications m1890.12 state estimation m1890.13 contingency analysis m1890.14 optimal power flow m1890.15 outage scheduler m1890.16 load forecasting m1890.17 inflow forecasting m1890.18 web server application m1890.19 host based ids for all machines m1890.20 software for data replica server m1890.21 software for centralised management system m1890.22 software for web server m1890.23 anti virus software for all machines m1890.24 database development system ( pds ) cum test bench for rtu and iccp integration m1890.25 dispatcher training simulator m1890.26 document management system m1890.27 identity management system m1890.28 hardware m1891 computer system hardware m1891.1 scada server m1891.2 ems applications server m1891.3 isr server with auxiliary memory m1891.4 data historian sever m1891.5 san box m1891.6 san management server m1891.7 nas box m1891.8 tape library m1891.9 san / nas lan m1891.10 iccp server m1891.11 nms server m1891.12 cfe server m1891.13 workstation console m1891.14 workstation console integrated with dual monitors m1891.15 workstation console integrated with single monitor m1891.16 lan switch m1891.17 lan switch for scada / ems lan m1891.18 lan switch for data acquisition lan m1891.19 lan switch for pds lan m1891.20 lan switch for iccp lan m1891.21 lan switch for external dmz lan m1891.22 lan switch for internal dmz lan m1891.23 24 port l 3 lan switch for management lan m1891.24 laptop for maintenance m1891.25 wan routers with firewall m1891.26 wan router for rtu communication ( 4 x g.703 ports configurable upto 2mbps, 4 ethernet ports ) m1891.27 wan router for iccp and remote consoles communication ( 4 x g.703 ports configurable upto 2mbps, 4 ethernet ports ) m1891.28 printers m1891.29 color laser printer m1891.30 multi functional printer m1891.31 time & frequency system and external displays m1891.32 time & frequency system ( gps based ) m1891.33 digital display for day m1891.34 digital display for time m1891.35 digital display for frequency m1891.36 digital display for display of abt time block m1891.37 web system m1891.38 web servers m1891.39 firewall with nips ( internal ) m1891.40 firewall with nips ( external ) m1891.41 centralized management console m1891.42 data replica server m1891.43 wan router cum firewall for connectivity with isp m1891.44 pds and rtu and iccp integration testing system consisting of m1891.45 pds server m1891.46 workstation console integrated with single monitor m1891.47 wan router m1891.48 video projection system m1891.49 video projection system ( 70 led based ) m1891.50 tower type video wall m1891.51 dts server m1891.52 workstation dual screen ( training console ) m1891.53 42 u server rack with kvm switch & rack mounted monitor m1891.54 remote consoles with single monitor m1891.55 remote console with single screen monitor m1891.56 colour inkjet printer m1891.57 router cum firewall m1891.58 remote console with single 55 screen monitor m1891.59 identity server m1891.60 server management console m1891.61 furniture m1891.62 u type workstation desks m1891.63 workstation desks m1891.64 chairs m1891.65 fireproof software storage box m1891.66 video conferencing system m1891.67 multi point conferencing unit m1891.68 configuration laptop with associate accessories m1891.69 video end points m1891.70 hd camera m1891.71 microphone base station m1891.72 wireless microphone m1891.73 collar microphone m1891.74 lcd video wall m1891.75 wall mounted line array speakers m1891.76 dual channel power amplifiers m1891.77 16 port terminal servers m1891.78 panel for servers with accessories m1892 auxiliary power supply m1892.1 40 kva ( 32kw at 0.8 pf ) ups running in parallel m1892.2 vrla type battery banks for above ups ( each bank of 76.8 kvah ) m1892.3 input acdb ( 150kva rating ) m1892.4 output acdb ( 100kva rating ) m1892.5 125 kva dg set m1892.6 accessories for maintenance of vrla type batteries m1892.7 ups control / monitoring console m1893 services m1893.1 integration with control centres on iccp m1893.2 integration with wams m1893.3 integration with the following: m1893.4 metering applications m1893.5 abt based scheduling software m1893.6 open access m1893.7 annual maintenance of round the clock comprehensive maintenance of software and hardware maintenance of overall ems / scad system of jusnl m1894 split ac 2t complete set with automatic stabilizer m1895 gis equipments m1895.1 400 kv m1895.2 220 kv m1895.3 132 kv m1896 hybrid switchgear m1896.1 400 kv m1896.2 220 kv m1896.3 132 kv m1897 hvac 5.5 tr m1898 surveillance system m1899 msic. civil works m1899.1 providing and fixing partly glazed pannelled particle with 25 micron satin finished anodized aluminum extracted section of size 63.0 mm x 38.1 mm x 2 mm of indalcolhindalco jindal for vertical top, intermidate members and 95mm x 44.5mm x 2mm hindalcoindalco jindal for bottom rails. the glazing shall be of 5.5 mm thick sheet glass of approved quality and panels with 12mm thick both side grey laminated 3 layered melamine faced teak wood particle board phenol bonded of approved shade etc all complete job m1899.2 supplying, fitting & fixing fully glazed sliding 2 track aluminium window with top end bottom outer frame 63x25x1.5 mm fixed with screw & sliding shutter with bottom h section 9x1.5 mm handle section with into truck section with 4 mm thick glass including all fittings all complete. m1899.3 supplying, fitting & fixing fully glazed sliding 3 track aluminium window with top end bottom outer frame 63x25x1.5 mm fixed with screw & sliding shutter with bottom h section 9x1.5 mm handle section with into truck section with 4 mm thick glass including all fittings all complete. m1899.4 providing & fixing openable fully glazed satin aluminum framed door shutters of microns anodized aluminum extruded section of size 44 x 44 x 2.5 mm for vertical 44 x 44 x 2.5 mm for top and 94 x 44 x 2.5 mm for bottom rail including 5.5 mm thick fault free glass fixed to the extruded section by means of glazing clips etc all complete. m1899.5 s / f / f comboard of coiosets , model twilight ( ewc pan ) worth strap of approved i.s.s mark with 15 littrers cistern............ e / i m1899.6 s / f / f urinal model senso art of approved i.s.s mark with other required fitting with all complete............... e / i m1899.7 s / f / f jet sprey of approved quality of jaguar or erquivalent make etc all m1899.8 supply, fitting and fixing ms pipe of approved quality all complete as per building specification and direction of e / i. m1899.9 boring excavation & others items drilling / casin / rope / cable / panel m1899.10 submersible pump 3hp, 5hp m1899.11 black roll pipe of 15 mm dia m1899.12 plain fibre sheet m1899.13 colour fibre sheet m1899.14 fire proof partition wall m1899.15 acid resistance tiles...

Jharkhand State Electricity Board - Jharkhand

26395817 supply of list of materials ( i ) rail pole 60 kgs 13 meter ( ii ) rail pole 52 kgs 13 meter ( iii ) rs joist pole 9.3 meter ( 175x85mm ) 19.6 kgs per mtr ( iv ) rs joist pole 9 meter ( 116x100mm ) 23 kgs per mtr ( v ) 125x70x5 rs gi joist 8mtr ( 13.3kg / mtr ) ( vi ) 125x70x6 rs gi joist 5mtr ( 13.3kg / mtr ) ( vii ) h beam pole 11 meters ( 152x152mm ) 37.1 kgs per mtr ( viii ) h beams 152 x 152 mm., 37.1 kg. / mtr. 13 mtr. long = 482.3 kg ( ix ) h beams 152 x 152 mm., 37.1 kg. / mtr. 9 mtr. long= 333.9 kg ( x ) h beams 152 x 152 mm., 37.1 kg. / mtr. 7 mtr. long= 259.7 kg ( xi ) psc pole 400 kg w.l ( 9 mtr. ) ( xii ) psc pole 200 kg w.l ( 8 mtr. ) ( xiii ) steel tubular pole ( sp 28 ) of 9 meter ( xiv ) steel tubular pole ( sp 55 ) of 11 meter ( xv ) steel tubular pole ( sp 72 ) of 13meter m1629 acsr conductors ( i ) acsr panther conductor ( 232 sq. mm ) ( ii ) acsr wolf conductor ( 150 sq. mm ) ( iii ) acsr dog conductor ( 100 sq. mm ) ( iv ) acsr racoon conductor ( 80 sq. mm ) ( v ) acsr rabbit conductor ( 55 mm2 ) ( vi ) acsr weasel conductor ( 34 sq. mm ) m1630 insulators & h / w fittings ( i ) 33 kv pin insulator 10 kn with pin ( porcelain type ) ( ii ) 33 kv polymer pin insulators 10 kn with gi pin ( iii ) 33 kv disc insulator ( polymer type ) 90 kn with h / w fitting ( iv ) 33 kv disc. insulator ( porcelain type ) 70 kn with h / w fitting ( v ) 33 kv disc insulator ( polymer type ) 70 kn with h / w fitting ( vi ) suspension hardware suitable for panther conductor ( vii ) tension hardware suitable for panther conductor ( viii ) 11 kv pin insulator 5kn with pin ( porcelain type ) ( ix ) 11 kv pin insulator 5 kn with pin ( polymer type ) ( x ) 11 kv disc insulator ( polymer type ) 70 kn with h / w ( xi ) 11 kv disc insulator ( porcelain type ) 70 kn with h / w ( xii ) 11 kv disc insulator ( porcelain type ) 45 kn with h / w ( xiii ) 11 kv disc insulator ( polymer type ) 45 kn with h / w ( xiv ) lt pin insulator with pin ( porcelain type ) ( xv ) lt pin insulator ( porcelain type ) ( xvi ) lt pin ( xvii ) lt shackle insulator ( porcelain type ) ( xviii ) lt shackle strip with bolts and nut ( xix ) 33 kv post insulator 10 kn ( polymer ) ( xx ) 11 kv post insulator 5 kn ( polymer ) ( xxi ) 33 kv stay insulator ( xxii ) 11 kv stay insulator ( xxiii ) lt stay insulator ( xxiv ) mid span compression joints suitable for acsr panther conductor ( xxv ) repairing sleeve suitable for acsr panther conductor m1631 isolator ( i ) 33 kv isolator 800 amp , 3 phase, with earth switch ( ii ) 33 kv isolator 800 amp , 3 phase, with out earth switch ( iii ) 33 kv isolator 600 amp, 3 phase, without earth switch ( iv ) 33 kv isolator 600 amp, 3 phase, with earth switch ( v ) 33 kv isolator 400 amp, 3 phase, with earth switch ( vi ) 33 kv isolator 400 amp, 3 phase, without earth switch ( vii ) 11 kv isolator 800 amp, 3 phase, with earth switch ( viii ) 11 kv isolator 800 amp, 3 phase, without earth switch ( ix ) 12 kv, 630 a, 25 ka for 3 seconds, 3 phase double break center rotating type ( dbcr ) , indoor floor mounted motorized off load isolator panel along with all required accessories complete ( x ) 11 kv isolator 1200 amp, 3 phase, with earth switch ( xi ) 11 kv isolator 1200 amp, 3 phase, without earth switch ( xii ) 11 kv isolator 800 amp, 3 phase, with earth switch ( xiii ) 11 kv isolator 800 amp, 3 phase, without earth switch ( xiv ) 11 kv isolator 600 amp, 3 phase, with earth switch ( xv ) 11 kv isolator 600 amp, 3 phase, without earth switch ( xvi ) 11 kv isolator 400 amp, 3 phase, without earth switch ( xvii ) 11 kv isolator 400 amp, 3 phase, with earth switch ( xviii ) 11 kv isolator 200 amp single phase m1632 ab switch ( i ) 33 kv 3 pin type, 3 phase, ab switch 800 amp ( porcelain type ) ( ii ) 33 kv 3 pin type, 3 phase, ab switch 600 amp ( porcelain type ) ( iii ) 33 kv 3 pin type, 3 phase, ab switch 600 amp ( polymer type ) ( iv ) 11 kv 3 pin type, 3 phase, ab switch 800 amp ( porcelain type ) ( v ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( porcelain type ) ( vi ) 11 kv 3 pin type, 3 phase, ab switch 400 amp ( polymer type ) ( vii ) 11kv ab switch 200 amps ( single break ) ( viii ) 12 kv, 3 ph, 200 a, 3 pin type, horizontal mounting type, gang operated, ab switch along with support insulators, base channel, down pipe, arcing horns etc. complete as per technical specifications, scope of works and approved drawings ( ix ) 36kv 630a, 25ka, 3 ph, 3 pin type, horizontal mounting type , gang operated, ab switch along with support insulators, base channel down pipe, arcing horns etc. complete as per technical specifications, scope of works and approved drawings m1633 lightening arrestor ( 9kv 5ka ) line type m1634 earthing ( i ) 25mm dia ms rod 3 m long for earth mat ( ii ) spike earthing made of 20mm gi solid rod ( iii ) g.i earthing strip size 75x8 mm ( iv ) g.i earthing strip size 35x3 mm ( v ) g.i earthing strip size 35x4 mm ( vi ) g.i earthing strip size 40x4 mm ( vii ) g.i earthing strip size 40x5 mm ( viii ) insulated gi / alum.flexible wire 16 sq.mm ( ix ) ace chemrod ( artificial concept of earthing by chemical rod ) : ace chemrod earthing electrode ( consisting mild steel galvanised pipe of size 2500 mm in length x 48 mm outer dia. x 2 mm thick, ms rod of size 2575 mm x 16 mm be welded with bottom. the epoxy insulator of not less than 100 mm length is to be fixed on top of mild steel galvanised pipe. a highly conductive substance is to be filled in residual gap between pipe and rod ) with highly conductive substances not less than 25 kg for soil treatment ( x ) earthing complete conventional type having intermittent layer of charcoal and salt m1635 stay set 1 2 ( i ) gi stay set complete for d / s / s ( 1900x 16mm ) with staywire 7 / 12 swg and guy insulator ( ii ) gi stay set complete for d / s / s ( 1900x 20mm ) with staywire 7 / 10 swg and guy insulator ( iii ) 33 kv stay set complete ( 1900x20 mm ) with staywire 7 / 8 swg and guy insulator ( iv ) stay set complete ( 1800x20mm ) with stay wire 7 / 10 swg & guy insulator ( galvanised ) ( v ) 11 kv stay set complete ( 1800x16 mm ) with stay wire 7 / 10 swg and guy insulator ( vi ) lt stay set complete ( 1700x16 mm ) with stay wire 7 / 12 swg ( vii ) gi stay wire no. 7 / 8, 7 / 10, 7 / 12, 7 / 14, 7 / 16 m1636 p.g.clamps ( i ) p g clamp for 232 / 150 sq mm conductor ( ii ) p g clamp for 80 / 100mm2 ( iii ) p g clamps for 34 / 55mm2 ( iv ) bimettalic clamps for distribution transformers ht side ( 25 to 200 kva ) ( v ) bimettalic clamps for distribution transformers ht side above ( 200 kva ) ( vi ) bimettalic clamps for distribution transformers lt side ( 25 to 200 kva ) ( vii ) bimettalic clamps for distribution transformers lt side above ( 200 kva ) ( viii ) bimettalic clamps for power transformer 5 mva ( ix ) bimettalic clamps for power transformer 10 mva ( x ) bimettalic clamps for vcbs for 33kv and 11 kv ( xi ) bimettalic clamps for ct pt unit ( xii ) p g clamp 3 bolt for abt meters m1637 structures, gantry columns and base plates ( i ) structure for 33kv lightening arrestor [ non galvanized ] ( ii ) structure for 33kv lightening arrestor [ galvanized ] ( iii ) ms structure for 33 kv isolator ( iv ) ms structure for 11 kv isolator ( v ) structure for 33 kv isolator [ galvanized ] ( vi ) structure for 11 kv isolator [ galvanized ] ( vii ) ms structure for 33 kv pt ( non galvanised ) ( viii ) structure for 33 kv pt [ galvanized ] ( ix ) ms structure for 11 kv pt ( non galvanised ) ( x ) structure for 11 kv pt [ galvanized ] ( xi ) ms structure for post insulator for both 33kv and 11kv ( xii ) structure for post insulator for both 33kv [ galvanized ] ( xiii ) structure for post insulator for 11kv [ galvanized ] ( xiv ) ms structure for 33 kv hg fuse set ( non galvanised ) ( xv ) structure for 33 kv hg fuse set [ galvanized ] ( xvi ) a swing bus structure ( xvii ) gantry column, girder structures for 33 / 11 kv pss for single transformer [ galvanized ] ( xviii ) a structures for top mounted ab switch on 33 kv bus [ galvanized ] ( xix ) a structures for top mounted ab switch on 11 kv bus [ galvanized ] ( xx ) a structures for 11 kv take off with top mounted ab switch and provision of lightening arrester [ galvanized ] ( xxi ) gi base plate for 33kv ( 500x500x10 mm ) avg weight 19.6kg / plate ( xxii ) stone base plate for 11 kv, dss, lt m1638 current and potential transformers ( i ) 33 kv ct outdoor oil immersed type, 3 core, 200 100 / 5 5 1 amp, class 0.5 for differential protection ( ii ) 33 kv ct outdoor oil immersed type, 3 core, 300 150 / 5 5 1 amp, class 0.5 for differential protection ( iii ) 33 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering 1 2 ( iv ) 33 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( v ) 33 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vi ) 33 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( vii ) 33 kv combined ct & pt unit with junction box complete in all respect ( viii ) 11 kv ct outdoor oil immersed type, 3 core, 600 300 / 5 5 1amp, class 0.5 for differential protection ( ix ) 11 kv ct 800 400 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( x ) 11 kv ct 400 200 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xi ) 11 kv ct 300 150 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xii ) 11 kv ct 200 100 / 5 5a, 2 core, 15va , 5p10 for protection, 10va, 0.5 accuracy for metering ( xiii ) l.t. ct ratio 50 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xiv ) l.t. ct ratio 100 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xv ) l.t. ct ratio 200 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xvi ) l.t. ct ratio 300 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xvii ) l.t. ct ratio 400 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xviii ) l.t. ct ratio 500 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xix ) l.t. ct ratio 600 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xx ) l.t. ct ratio 800 / 5a, 5va, 0.5 accuracy for metering, epoxy casted ( xxi ) 33 kv / 110v p.t, 50va, class 0.5 ( xxii ) 11 kv / 110v p.t , 30va, class 0.5 ( xxiii ) 600 400 200 / 5 5 5a ( 0.2s & 5p20 ) ct& vcb ( xxiv ) 600 400 200 100 / 5 5 5 5a ( 0.2s & 5p20 ) ct& vcb ( xxv ) 600 400 200 / 5 5 5a ( 0.5s ps & 5p20 ) ct& vcb ( xxvi ) 33 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) ( xxvii ) 11 / √3 / 110 / √3 / 110 / √3 pt ( core 1:0.5s, core2:3p ) m1639 power transformer ( i ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( off load tap changer ) ( ii ) 33 / 11 kv power transformer 10 mva copper wound, crgo core ( on load tap changer ) ( iii ) 33 / 11 kv power transformer 8 mva copper wound, crgo core ( off load tap changer ) ( iv ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( off load tap changer ) ( v ) 33 / 11 kv, 10 / 12.5 mva, oil type, two winding, 3 phase, dyn11, 50 hz, onan / onaf transformer with & 8.35% impedance on 12.5 mva with oltc ( vi ) 33 / 11 kv power transformer 05 mva copper wound, crgo core ( on load tap changer ) m1640 distribution transformer ( i ) 11 / 0.433 kv distribution transformer 500 kva, copper wound, crgo m4 core onan; bis level 2 ( ii ) 11 / 0.433 kv distribution transformer 200 kva, aluminium winding, stack type crgo core fitted, completely self protected; 4 star bee rating ; bis level 2 ( iii ) bis energy efficiency level ii, 11 / 0.433 kv100 kva, al. wd., stack type crgo core, distribution transformer fitted with lightning arrester ( la ) and completely self–protected ( csp ) ( iv ) 11 / 0.433 kv distribution transformer 100 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating bis level 2 ( v ) bis energy efficiency level ii, 11 / 0.433 kv 63 kva, al. wd., stack type crgo core, distribution transformer fitted with lightning arrester ( la ) and completely self–protected ( csp ) ( vi ) 11 / 0.433 kv distribution transformer 63 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating ; bis level 2 ( vii ) bis energy efficiency level 2 type tested, 11 / .433 kv 25 kva, al. wd., stack type crgo core, distribution transformer fitted with lightning arrester ( la ) and completely self –protected ( csp ) ( viii ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; 4 star bee rating bis level 2 ( ix ) 11 / 0.433 kv, 500 kva, dry type, two winding, 3 phase, dyn11, 50 hz, an, off circuit tap changer with + / 5% in steps of 2.5%on hv side for station transformer & 4% impedance with losses as per cbip ( x ) lighting transformer of 415 / 415v, 50 kva, dry type, two windin, 3 phase, dyn11, 50 hz with 4% impedence ( xi ) 11 / 0.433 kv distribution transformer 25 kva, aluminium winding, stack type crgo core fitted; 3 star bee rating ; bis level 1 ( xii ) 11 / 0.433 kv dtr 250kva trolley mounted ( xiii ) 11 / 0.433 kv dtr 250kva trolley mounted m1641 distribution box ( i ) lt distribution box suitable for 500 kva transformer ( 800 a, isolator & 12 tp mccb of 160 a ) ( ii ) lt distribution box suitable for 315 kva transformer ( 600 a, isolator & 9 tp mccb of 160 a ) ( iii ) lt distribution box suitable for 200 kva transformer ( 400 a, isolator & 6 tp mccb of 120 a ) ( iv ) lt distribution box suitable for 100 kva transformer ( 200 a, isolator & 6 tp mccb of 200 a ) ( v ) ltdb for 200kva, isolator 400a, incoming mccb 4p, 400a, 50ka, outgoing mccb 3p 100a, 36ka ( vi ) ltdb for 100kva & 63kva, isolator 250a, incoming mccb 4p, 200a, 36ka, outgoing mccb 3p 100a, 36ka ( vii ) ltdb for 25kva, isolator 63a, incoming mccb 4p, 63a, 20ka, outgoing mccb 3p 32a, 20ka ( viii ) lt distribution box suitable for 63 kva transformer ( 200 a, isolator & 6 tp mccb of 100 a ) ( ix ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 6 out ( dist. box for fixing on pole suitable ab xlpe cable ) ( x ) spring loaded cp multi conn bus bar in insulated box single phase 1 in 9 out ( dist. box for fixing on pole suitable xlpe cable ) ( xi ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 3 out ( dist. box for fixing on pole suitable ab xlpe cable ) ( xii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 5 out ( dist. box for fixing on pole suitable ab xlpe cable ) ( xiii ) spring loaded cp multi conn bus bar in insulated box three phase 1 in 8 out ( dist. box for fixing on pole suitable ab xlpe cable ) ( xiv ) spring loaded distribution bus bar insulated box for fixing on pole suitable for ab xlpe cable and three phase connection 1 incoming and out going 3 phase connection as per field requirement ( xv ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 750 kva transformer ( xvi ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 500 kva transformer ( xvii ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 400 kva transformer ( xviii ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 315 kva transformer ( xix ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 250 kva transformer ( xx ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 200 kva transformer ( xxi ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 100 kva transformer ( xxii ) bus bar ( aliuminium ) r, y, b & n phase of l.t. distribution box for 63 kva transformer ( xxiii ) acb 1250a, 4p, 50ka ( xxiv ) acb 1000a, 4p, 50ka ( xxv ) acb 1250a, 3p, 50ka ( xxvi ) acb 1000a, 3p, 50ka ( xxvii ) mccb 800a, 4p, 36ka ( xxviii ) mccb 700a, 4p, 36ka ( xxix ) mccb 300a, 4p, 36ka ( xxx ) mccb 200a, 4p, 36ka ( xxxi ) mccb 125a, 4p, 36ka ( xxxii ) mccb 100a, 4p, 36ka ( xxxiii ) mccb 63a, 4p, 36ka ( xxxiv ) mccb 800a, 3p, 36ka ( xxxv ) mccb 700a, 3p, 36ka ( xxxvi ) mccb 630a, 3p, 36ka ( xxxvii ) mccb 500a, 3p, 36ka ( xxxviii ) mccb 400a, 3p, 36ka ( xxxix ) mccb 300a, 3p, 36ka ( xl ) mccb 250a, 3p, 36ka ( xli ) mccb 200a, 3p, 36ka ( xlii ) mccb 160a, 3p, 36ka ( xliii ) mccb 125a, 3p, 36ka ( xliv ) mccb 100a, 3p, 36ka ( xlv ) mccb 63a, 3p, 36ka ( xlvi ) mccb single pole 200a, 36ka ( xlvii ) mccb single pole 160a, 36ka ( xlviii ) mccb single pole 120a, 36ka ( xlix ) mccb single pole 100a, 36ka ( l ) mccb single pole 32a, 36ka ( li ) panel lock m1642 vcb, c&r panel ( i ) 33 kv vcb, 1250 amp., outdoor type, 26.3 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 1200 600 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering.pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( ii ) 33 kv vcb, 1250 amp., outdoor type, 26.3 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 600 300 / 1 1a 400 200 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering.pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( iii ) 33 kv vcb, 800 amp., outdoor type, 16 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 400 200 / 1 1a or 200 100 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering.pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( iv ) 33 kv vcb, 1250 amp., outdoor type, 16 ka for 1 sec rpturing capacty , with cr pannel, & c.t. ratio 600 300 / 1 1a 400 200 / 1 1a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering.pt 33kv / 110v, accuracy class 0.5, va burden 50va, ( v ) 11 kv vcb, outdoor type, 1250 a, 25 ka for 3 sec. rupturing capacity wth c&r panel.ct 800 400 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( vi ) 11 kv vcb, outdoor type, 630 a, 25 ka for 3 sec. rupturing capacity wth c&r panel.ct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( vii ) 11 kv vcb, outdoor type, 800 a, for incoming, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated withct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( viii ) 11 kv vcb, outdoor type, 400 a, for outgoing, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated withct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( ix ) 11 kv vcb, outdoor type, 400 a, for capacitor, 18.4 ka for 1 sec. rupturing capacity with panel ( indoor ) 24 v dc operated withct 600 300 / 5 5a or 400 200 / 5 5a, 2 core, 15va, 5p10 for protection, accuracy 0.5, 10va for metering. p.t. 33kv / 110v, accuracy class 0.5, 30 va ( x ) indoor type control and relay panel for 11kv, 3phase, 1250 a vcb ( transformer breaker ) consisting of a meter, volt meter, relays & accessories complete as per specifications for transformer breaker protection ( xi ) indoor type control and relay panel for 11 kv 3 phase, 1250 a vcb ( feeder breakers ) consisting of a meter, volt meter, relays & accessories complete for feeder breaker protection as per technical specifications. ( xii ) indoor type control and relay panel for 33kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. ( xiii ) indoor type control and relay panel for 33kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays accessories complete. ( xiv ) indoor type control and relay panel for 11kv, vcb ( transformer breaker ) consisting of a meter, volt meter, relays accessories complete. ( xv ) indoor type control and relay panel for 11kv, vcb ( feeder breaker ) consisting of a meter, volt meter, relays & accessories complete. m1643 ( ) distribution board ( i ) 415v ac power distribution board ( ii ) 30v dc distribution board m1644 ( ) pipe connector ( i ) aluminium pipe connector ( ii ) connector pipe to panther ( iii ) connector panther to panther ( iv ) connector panther to ab switch ( v ) connector pipe to pipe ( vi ) connector pipe to dog ( vii ) connector pipe to ab switch ( viii ) connector dog to ab switch m1645 copper control cable ( i ) 2.5 mm2 copper 2 core control cable ( armoured ) ( ii ) 2.5 mm2 copper 2 core control cable ( unarmoured ) ( iii ) 2.5 mm2 copper 4 core control cable ( armoured ) ( iv ) 2.5 mm2 copper 4 core control cable ( unarmoured ) ( v ) 2.5 mm2 copper 6 core control cable ( armoured ) ( vi ) 2.5 mm² copper 6 core un armourd cable ( vii ) 7 core x 2.5 sq.mm. armoured control cable ( viii ) 2.5 mm2 copper 8 core control cable ( unarmoured ) 1 2 ( ix ) 2.5 mm2 copper 10 core control cable ( armoured ) ( x ) 2.5 mm2 copper 10 core control cable ( unarmoured ) ( xi ) 2.5 mm2 copper 12 core control cable ( armoured ) ( xii ) 2.5 mm2 copper 12 core control cable ( unarmoured ) ( xiii ) 19 core x 2.5 sq.mm.armoured control cable m1646 capacitor bank ( i ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 3600 kvar ( ii ) 1815 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 kvar+726 kvar+726 kvar 12.1 kv bank shall be complete with capacitor units of 121 kvar at 6.98 kv including allied materials such as suitable size of aluminium busbars, pin / pos ( iii ) fully automatic capacitor bank with automatic control panel, isolator, indoor type suitable vacuum circuit breaker, mounting structures etc as required as per technical specifications, drawings, scope of the works of following capacities: ( banks in muiltiple of 600 kvar as per specification ) 1200 kvar ( iv ) 1089 kvar 12.1 kv 3 phase 50 hz outdoor type capacitor bank having step as 363 m1647 metering equipment ( i ) 33 kv metering cubicle with pt & ct , 0.5s accuracy class for ct and 0.5 accuracy class for pt ( ii ) 33 kv outdoor type oil immersed ct pt combined metering unit 0.5s accuracy class for ct and 0.5 accuracy class for ( iii ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( modular rack mounted ) ( iv ) 33 kv, three phase three wire / three phase four wire, accuracy class 0.2s, dlms compliant abt meter ( projection type ) ( v ) 33 kv / 110 v, three phase four wire, ( 0.2s accuracy class for ct and 0.2 accuracy class for pt ) , ratio 1600 / 1a or 1200 / 1a ct pt combined metering unit for feeder ( vi ) metering panel, data concentrator unit ( dcu ) with modem ( vii ) structure for 33 kv metering unit ( viii ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.2s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( ix ) ht electronic trivector static meter, 3 phase 4 wire, accuracy class 0.5s ( – / 110v & – / 5a ) ( dlms complaint ) with compatible gprs modem with meter box ( x ) trivector energy meter of 800 / 5 amp for 100 kva dtr ( xi ) trivector energy meter of 400 / 5 amp ( xii ) 11 kv, outdoor type oil immersed ct pt combined metering unit, 3 phase 4 wire ( 11kv / 110v ) [ 12 kv pt 50va burden 0.5 accuracy class; ct 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 15 va, 0.5 accuracy class ] ( xiii ) 11 kv metering cubicle with pt ratio 11kv / √3 / 110v and ct ratio 20 / 5a, 30 / 5a, 60 / 5a, 100 / 5a, 200 / 5a, 400 / 5a, 0.5 accuracy class for both ( xiv ) ltct electronic meter, ct ratio ( 1000 / 5 ) , 3 phase 4 wire with meter box, class 0.5s accuracy ( xv ) ltct electronic meter ( 200 / 5 ) 3 phase 4 wire with meter box, class 0.5s accuracy ( xvi ) ltct electronic meter ( 150 / 5 ) 3 phase 4 wire with meter box, class 0.5s accuracy ( xvii ) ltct electronic meter ( 100 / 5 ) 3 phase 4 wire with meter box, class 0.5 accuracy ( xviii ) ac 3 phase, 4 wire, 40 200amp lt electronic trivector accuracy class 1.0 dlms compliant category a meter with inbuilt cts and inbuilt gsm / gprs modem for di rating upto 100 kva ( xix ) structure for d.t meter ( xx ) ac 3 phase dtr meter complete set above 100kva 400 / 5a ( xxi ) lt electronic trivector meter 40 200 amp. ( xxii ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 200 / 5a ( xxiii ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 5a ( xxiv ) 11 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 5a ( xxv ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 400 / 1a ( xxvi ) 33 kv / 110, 3 phase 4 wire accuracy class dlms compliant trivector energy meter ratio 600 / 1a ( xxvii ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 1a ( xxviii ) 11kv / 110, 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 400 / 5a ( xxix ) 11 kv / 110 v 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 200 / 5 a ( xxx ) 33kv / 110v , 3 phase, 4 wire , accuracy class 0.5 ct pt, combined metering unit for feeder, ratio 600 / 1a ( xxxi ) 11 kv / 110, 3 phase 4 wire accuracty class 0.5 ct pt combined metering unit for feeder, ratio 600 / 5 a ( xxxii ) dlms compliant, single phase 2 wire 5 30 amp. 1.0 accuracy, class ac statics single phase meter with meter box ( xxxiii ) lt static energy meter, 3 phase 4 wire, direct connected, 100 amp. with meter box, class 1.0 accuracy ( xxxiv ) three phase 4 wire ac static whole current meter, electronic energy meter with box ( 10 60 ) amp 1 2 ( xxxv ) single phase electronic meter, two wire, 5 30 amp. class 1.0 accuracy with box ( xxxvi ) single phase rf meter with box as per is 13779 standards, dlms compliant ( xxxvii ) three phase rf meter with box as per is 13779 standards, dlms compliant ( xxxviii ) single phase rs 232 / 485 prepaid energy meter ( xxxix ) three phase rs 232 / 485 prepaid energy meter ( xl ) single phase rf prepaid energy meter ( xli ) three phase rf prepaid energy meter ( xlii ) single phase gprs / gsm prepaid energy meter ( xliii ) three phase gprs / gsm prepaid energy meter ( xliv ) supply of l.t. meter boxes ( metering cubicle ) with l.t cts of different ratio, class of accuracy 0.5 along with pvc wire for connection of metering. ( xlv ) l.t c.t. resin casted having ratio 100 / 5a class of accuracy 0.5 ( xlvi ) l.t c.t. resin casted having ratio 150 / 5a class of accuracy 0.5 ( xlvii ) l.t c.t. resin casted having ratio 200 / 5a class of accuracy 0.5 ( xlviii ) l.t c.t. resin casted having ratio 300 / 5a class of accuracy 0.5 ( xlix ) l.t c.t. resin casted having ratio 400 / 5a class of accuracy 0.5 ( l ) l.t c.t. resin casted having ratio 600 / 5a class of accuracy 0.5 ( li ) l.t c.t. resin casted having ratio 800 / 5a class of accuracy 0.5 ( lii ) l.t c.t. resin casted having ratio 1000 / 5a class of accuracy 0.5 ( liii ) pvc cable gland sizes 20 mm, ( liv ) pvc cable gland sizes 25 mm, ( lv ) pvc cable gland sizes 32 mm ( lvi ) pvc cable gland sizes 40 mm ( lvii ) pvc cable gland sizes 50 mm ( lviii ) pvc cable gland sizes 63 mm ( lix ) pvc cable gland sizes 75 mm m1648 gi service pipe ( i ) gi service pipe 25 mm diameter 3 mtr length ( ii ) gi service pipe 40 mm diameter 3 mtr length ( iii ) gi service pipe 60mm diameter 3 mtr length ( iv ) g.i. pipe 3 dia m1649 ring main units ( i ) 11 kv 3 way rmu, 2od + 1vl, one incomer + one breaker + one outgoing ( ii ) 11 kv 4 way rmu, 2od + 2vl, ( one incomer + two breakers + one outgoing ( iii ) 11 kv 5 way rmu, 2od + 3vl, ( one incomer + three breakers + one outgoing ) ( iv ) 11 kv 6 way rmu, 2od + 4vl, ( one incomer + four breakers + one outgoing m1650 xlpe insulated cables ( i ) 33 kv ht xlpe cable single core 630mm2 ( armoured ) ( ii ) 1c x 400mm2 cable ( 33 kv power cable ) ( iii ) 33 kv ht xlpe cable 3 core 400 sq mm ( armoured ) ( iv ) 33 kv ht xlpe cable 3 core 300mm2 ( armoured ) ( v ) 33 kv ht xlpe cable 3 core 240mm2 ( armoured ) ( vi ) 33 kv ht xlpe cable 3 core 185mm2 ( armoured ) ( vii ) 33 kv ht xlpe cable 3 core 150mm2 ( armoured ) ( viii ) 33 kv ht xlpe cable 3 core 120mm2 ( armoured ) ( ix ) 33 kv ht xlpe cable 3 core 95mm2 ( armoured ) ( x ) 33 kv ht xlpe cable 3 core 70mm2 ( armoured ) ( xi ) 33 kv ht xlpe cable 3 core 50mm2 ( armoured ) 1 2 ( xii ) 3core x 35 sq. mm cable ( xiii ) 11 kv xlpe cable single core 630mm2 ( armoured ) ( xiv ) 11 kv xlpe cable single core 120mm2 ( armoured ) ( xv ) 11 kv xlpe cable single core 70mm2 ( armoured ) ( xvi ) 11 kv xlpe cable single core 50mm2 ( armoured ) ( xvii ) 11 kv xlpe cable single core 35mm2 ( armoured ) ( xviii ) 3core x 630sq mm ( 11 kv power cable ) ( xix ) 11 kv xlpe cable 3 core 25mm2 ( armoured ) ( xx ) power cable for dt meter 120 sq.mm unarmoured ( xxi ) power cable for dt meter 240 sq.mm unarmoured ( xxii ) power cable 240 sq. mm. ( unarmoured ) ( xxiii ) xlpe cable 4 core 16 mm2 ( xxiv ) lt xlpe cable 4 core 16mm2 ( unarmoured ) ( xxv ) lt xlpe cable 4 core 25mm2 ( armoured ) ( xxvi ) lt xlpe cable 3.5 core 300mm2 ( armoured ) ( xxvii ) lt xlpe cable 3.5 core 185mm2 ( armoured ) ( xxviii ) lt xlpe cable 3.5 core 120mm2 ( armoured ) ( xxix ) lt xlpe cable 3.5 core 95 mm2 ( armoured ) ( xxx ) lt xlpe cable 3.5 core 50mm2 ( armoured ) ( xxxi ) lt xlpe cable 3.5 core 25mm2 ( armoured ) ( xxxii ) lt xlpe cable 2 core 10mm2 ( armoured ) ( xxxiii ) lt xlpe cable 2 core 6mm2 ( armoured ) ( xxxiv ) lt xlpe cable 1cx120 sqmm ( xxxv ) lt xlpe single core cable 95 mm2 ( armoured ) ( xxxvi ) lt xlpe single core cable 50 mm2 ( armoured ) ( xxxvii ) lt xlpe single core cable 25 mm2 ( armoured ) ( xxxviii ) lt xlpe cable 3.5 core 35 sq. mm. ( armoured ) ( xxxix ) lt xlpe cable 3.5 core 70 sq. mm. ( armoured ) ( xl ) lt xlpe single core 1100 v cable 1*35 sqmm ( xli ) lt xlpe single core unarmoured 1 x 35sqmm ( xlii ) lt xlpe single core unarmoured 1 x 50 sqmm ( xliii ) lt xlpe single core unarmoured 1 x 240 sqmm ( xliv ) lt xlpe single core unarmoured 1 x 400 sqmm ( xlv ) cable 2.5 core x 240 sq mm ( xlvi ) lt xlpe single core unarmoured 1 x 70 sqmm ( xlvii ) cable 2 core x 16sq mm m1651 pvc insulated cables ( i ) 10 core 2.5 sqmm armoured, stranded copper conductor, pvc insulated and pvc sheathed cable ( ii ) 6 core 2.5 sqmm armoured, stranded copper conductor, pvc insulated and pvc sheathed cable ( iii ) 3.5 core 300 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( iv ) 3.5 core 240 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( v ) 3.5 core 185 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vi ) 3.5 core 150 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( vii ) 3.5 core 70 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( viii ) 3.5 core 35 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( ix ) 2 core 16 sq. mm armoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable 1 2 ( x ) 2 core 2.5 sqmm armoured, stranded copper conductor, pvc insulated and pvc sheathed cable ( xi ) 1 core 50 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( xii ) 1 core 70 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( xiii ) 1 core 120 sq. mm unarmoured, stranded aluminium conductor, pvc insulated and pvc sheathed cable ( xiv ) lt pvc cable 3.5 core 95 mm2 ( armoured ) ( xv ) lt pvc cable 3.5 core 10 mm2 ( armoured ) ( xvi ) lt pvc cable 3.5 core 6 mm2 ( armoured ) ( xvii ) lt pvc cable 2 core 16 mm2 ( armoured ) ( xviii ) lt pvc cable 2 core 10 mm2 ( armoured ) ( xix ) lt pvc cable 2 core 6 mm2 ( armoured ) ( xx ) lt pvc cable 2 core 4 mm2 ( armoured ) ( xxi ) lt pvc cable 1 core 16 mm2 ( armoured ) ( xxii ) lt pvc cable 1 core 50 mm2 ( armoured ) ( xxiii ) lt pvc cable 1 core 70 mm2 ( armoured ) ( xxiv ) lt pvc cable 1 core 150 mm2 ( armoured ) ( xxv ) lt pvc cable 1 core 300 mm2 ( armoured ) ( xxvi ) pvc single phase service cable 3.5 core 25 mm2 ( amoured ) ( xxvii ) 2.5 sq mm twin core pvc service cable ( xxviii ) 4 sq mm twin core pvc service cable ( xxix ) pvc single phase service cable 2 core 6 mm2 ( armoured ) ( xxx ) pvc single phase service cable 2 core 10 mm2 ( armoured ) ( xxxi ) pvc single phase service cable 2 core 2.5 mm2 ( unamoured ) ( xxxii ) pvc single phase service cable 2 core 4 mm2 ( unarmoured ) ( xxxiii ) pvc single phase service cable 2 core 6 mm2 ( unarmoured ) ( xxxiv ) pvc three phase service cable 4 core 6 mm2 ( armoured ) ( xxxv ) pvc three phase service cable 4 core 8 mm2 ( armoured ) ( xxxvi ) pvc three phase service cable 4 core 10 mm2 ( armoured ) ( xxxvii ) pvc three phase service cable 4 core 16 mm2 ( armoured ) ( xxxviii ) pvc three phase service cable 4 core 25 mm2 ( armoured ) ( xxxix ) pvc three phase service cable 4 core 10 mm2 ( unarmoured ) m1652 aerial bunched cables ( i ) 33 kv xlpe ht ab cable 3 core x 185mm2+240 mm2 bare messenger ( ii ) 33 kv xlpe ht ab cable 3 core x 120mm2+150 mm2 bare messenger ( iii ) 33 kv xlpe ht ab cable 3 core x 95mm2+120 mm2 bare messenger ( iv ) 11 kv xlpe ht ab cable 3cx185mm2+240mm2 bare messenger ( v ) 11 kv xlpe ht ab cable 3cx185mm2+150mm2 bare messenger ( vi ) 11 kv xlpe ht ab cable 3cx150mm2+120mm2 bare messenger ( vii ) 11kv xlpe ht ab cable 3cx120 mm2 + 95mm2 bare messenger ( viii ) 11 kv xlpe ht ab cable 3cx95mm2+80mm2 bare messenger ( ix ) 11 kv xlpe ht ab cable 3cx70mm2+70mm2 bare messenger ( x ) 11 kv xlpe ht ab cable 3cx50mm2+70mm2 bare messenger ( xi ) 11 kv xlpe ht ab cable 3cx35mm2+70mm2 bare messenger ( xii ) 11 kv xlpe ht ab cable 3cx35mm2+35mm2 bare messenger ( xiii ) lt xlpe ab cable 3cx120+1cx70+1cx16 mm2 ( xiv ) lt xlpe ab cable 3cx95 sqmm + 1x70 sqmm+1x70 sq mm ( xv ) lt xlpe ab cable 3cx95+1cx70+1cx16 mm2 ( xvi ) lt xlpe ab cable 3x70+1x50+1x16 ( street light ) mm2 ( xvii ) lt xlpe ab cable 3cx50 sqmm + 1x35 sqmm+1x16 sq mm ( xviii ) lt xlpe ab cable 3x50+1x25+1x35 mm2 ( xix ) lt xlpe ab cables 1x16 ( ph ) + 1x25 ( bare condustor + 1x16 ( insulated street lighting ) mm2 ( xx ) lt xlpe ab cable 3cx120+70mm2 ( xxi ) lt xlpe ab cable 3cx95+70mm2 ( xxii ) lt xlpe ab cable 3cx50+35mm2 ( xxiii ) lt xlpe ab cable 3cx35+25mm2 ( xxiv ) lt xlpe ab cable 3cx25+25mm2 ( xxv ) lt xlpe ab cable 3cx16+25mm2 ( xxvi ) lt xlpe ab cable 1cx16+25mm2 single phase ( xxvii ) lt xlpe ab cable 1cx35mm2 ( xxviii ) lt xlpe ab cable 1cx250mm2 ( xxix ) lt xlpe ab cable 1cx70mm2 ( xxx ) lt xlpe ab cable 1cx400mm2 m1653 ab cable accessories ( i ) 33 kv ab cable straight thru joint kit suitable for 35 70 sqmm ( ii ) 33 kv ab cable straight thru joint kit suitable for 95 120 sqmm ( iii ) 33 kv ab cable straight thru joint kit suitable for 185 sqmm ( iv ) 33 kv abc termination kit 95 120 sqmm ( v ) 33 kv abc termination kit 185 sqmm ( vi ) 33 kv abc termination kit 240 sqmm ( vii ) 11 kv ab cable straight thru joint kit suitable for 35 70 sqmm ( viii ) 11 kv ab cable straight thru joint kit suitable for 95 120 sqmm ( ix ) 11 kv abc termination kit 35 70 sqmm ( x ) 11 kv abc termination kit 95 120 sqmm ( xi ) lt pre insulated mid span joint suitable 25 mm2 phases ( xii ) lt pre insulated mid span joint suitable 35 mm2 phases ( xiii ) lt pre insulated mid span joint suitable 50 mm2 phases ( xiv ) lt pre insulated mid span joint suitable 70 mm2 phases ( xv ) lt pre insulated mid span joint suitable 95 mm2 phases ( xvi ) lt pre insulated mid span joint suitable 120 mm2 phases ( xvii ) pre insulated mid span joint suitable for 25 mm2 neutral messenger ( xviii ) pre insulated mid span joint suitable for 35 mm2 neutral messenger ( xix ) pre insulated mid span joint suitable for 50 mm2 neutral messenger ( xx ) insulation piercing connector for db charging ( xxi ) insulation piercing connector branching suitable for t joints ( xxii ) piercing connector for lt ab cable ( xxiii ) insulation piercing connector type i ( main 16 95 mm2 & tap 4 35 mm2 ) ( xxiv ) insulation piercing connector type ii ( main 16 95 mm2 & tap 16 95 sq mm ) ( xxv ) satellite connector ( xxvi ) lt ab cable accessory, 1.1mtr. stainless steel strap if207 ( 20x0.7 ) ( xxvii ) buckle for strap ( xxviii ) suspension clamp with eyehook ( xxix ) suspension clamp suitable for 25 70 sqmm baremessenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxx ) suspension clamp suitable for 35 95 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) 1 2 ( xxxi ) suspension clamp suitable for 95 150 sqmm bare messenger ( including 1 no. suspension clamp with bracket + 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxxii ) dead end clamp with eyehook ( xxxiii ) dead end clamp suitable for 25 50 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxxiv ) dead end clamp suitable for 70 95 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxxv ) dead end clamp suitable for 95 150 sqmm bare messenger ( including 1 no. dead end bracket + 1 no. dead end 1.5 mtr ss strap + 2 nos. ss buckle ) ( xxxvi ) dead end clamp assembly suitable upto 25 sq.mm bare messenger ( 01 dead end clamp with bracket, 2 mtr. stainless steel straps, 02 nos. buckles ) ( xxxvii ) suspension clamp assembly suitable for 95 mm2 bare messenger ( 01 nos. suspension clamp with bracket, 2 mtr. stainless stell straps 02 nos. buckles ( xxxviii ) service main anchor clamp for proper support of service cable ( 4mm2 and 10 mm2 ) ( xxxix ) eye hook ( xl ) stainless steel strip of 20mmx1mmx1000mm with buckle clip m1654 fabricated items ( i ) hot dip galvanized fabricated iron material for 33 kv line, lt line & dss ( ii ) 33 kv pole top bracket 50x10 mm flat [ galvanized ] ( iii ) 33 kv pole top bracket [ non galvanized ] ( iv ) 11kv pole top bracket 50x8 mm flat [ galvanized ] ( v ) 11 kv pole top bracket 50x8 mm ( f type ) [ non galvanized ] ( vi ) 11 kv f clamp / bracket ( vii ) 11 kv fish plate ( viii ) 33 kv fish plate ( for st pole 13 mtr. ) ( ix ) 33kv v cross arm for ( 100x50x6 mm ) [ galvanized ] ( x ) 33 kv v cross arm ( 100x 50x 6 mm ) [ non galvanized ] ( xi ) 33 kv dp special type v cross arm ( xii ) 11kv v cross arm ( 75x40x6 mm ) , 7.14 kg per meter [ galvanized ] ( xiii ) 11 kv v cross arm ( 75 x 40 x6 mm ) [ non galvanized ] ( xiv ) 11 kv guarding channel ( 75x40x6 mm ) ( xv ) 33 kv guarding channel ( 100x50x6mm ) ( xvi ) ms angle ( 65x65x6 mm ) for guarding of 33 kv, 11 kv, l.t line [ galvanized ] ( xvii ) ms angle ( 65x65x6 mm ) for guarding of 33 kv, 11 kv, l.t line [ non galvanized ] ( xviii ) top channel set ( 100x50x6 mm ) 9.56 kg per meter [ galvanized ] ( xix ) top channel set ( 100x50x6 mm ) 9.56 kg per meter [ non galvanized ] ( xx ) ms channel for ab switch ( 100x50x6 mm ) [ galvanized ] ( xxi ) ms channel ab switch ( 100x50x6 mm ) [ non galvanized ] ( xxii ) 33kv d p channel ( 100x50x6 mm ) 3150 mm long [ galvanized ] ( xxiii ) 33kv d p channel ( 100x50x6 mm ) 2200 mm long [ galvanized ] ( xxiv ) 33kv d p channel ( 100x50x6 mm ) 1.3 meter long [ galvanized ] ( xxv ) 33 kv d.p channel ( 100x50x6 mm ) 1.3 meter [ non galvanized ] ( xxvi ) 11kv d p channel ( 75x40x6 mm ) [ galvanized ] ( xxvii ) 11kv d.p channel ( 75x40x6mm ) [ non galvanized ] ( xxviii ) transformer base channel ( 100x50x6 mm ) [ galvanized ] ( xxix ) transformer base channel ( 100x50x6 mm ) [ non galvanized ] ( xxx ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ galvanized ] ( xxxi ) transformer belting ( 50x50x6 mm ) & belting support ( 40x40x6 mm ) [ non galvanized ] ( xxxii ) back clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( xxxiii ) back clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( xxxiv ) back clamp ( 50x6 mm ) for9 mtr 400kg psc pole [ galvanized ] ( xxxv ) back clamp ( 50x6 mm ) for 9mtr 400kg psc pole [ non galvanized ] ( xxxvi ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( xxxvii ) back clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( xxxviii ) back clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( xxxix ) back clamp ( 50x6 mm ) for tublar pole [ non galvanized ] ( xl ) support clamp for v cross arm for 60kg rail pole [ galvanized ] ( xli ) support clamp for v cross arm for 60kg rail pole [ non galvanized ] ( xlii ) support clamp for v cross arm for 9 mtr 400kg psc pole [ galvanized ] ( xliii ) support clamp for v cross arm for 9 mtr 400kg psc pole [ non galvanized ] ( xliv ) support clamp for v cross arm for 8 mtr 200kg psc pole [ galvanized ] ( xlv ) support clamp for v cross arm for 8 mtr 200kg psc pole [ non galvanized ] ( xlvi ) support clamp for v cross arm for tublar pole [ galvanized ] ( xlvii ) support clamp for v cross arm for tublar pole [ non galvanized ] ( xlviii ) back clamp for 33 kv dp special type v cross arm ( xlix ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ galvanized ] ( l ) back clamp ( 50x6 mm ) jointing / packing piece for 60kg rail pole [ non galvanized ] ( li ) back clamp ( 50x6 mm ) jointing / packing piece for 9 mtr 400kg psc pole [ galvanized ] ( lii ) back clamp ( 50x6 mm ) jointing / packing piece for 9 mtr 400kg psc pole [ non galvanized ] ( liii ) back clamp ( 50x6 mm ) jointing / packing piece for 8 mtr 200kg psc pole [ galvanized ] ( liv ) back clamp ( 50x6 mm ) jointing / packing piece for 8 mtr 200kg psc pole [ non galvanized ] ( lv ) back clamp ( 50x6 mm ) jointing / packing piece for tublar pole [ galvanized ] ( lvi ) back clamp ( 50x6 mm ) jointing / packing piece for tublar pole [ non galvanized ] ( lvii ) clamp for top channel 50x6 mm flat for 60kg rail pole [ galvanized ] ( lviii ) clamp for top channel 50x6 mm flat for 60kg rail pole [ non galvanized ] ( lix ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ galvanized ] ( lx ) clamp for top channel 50x6 mm flat for 9 mtr 400kg psc pole [ non galvanized ] ( lxi ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ galvanized ] ( lxii ) clamp for top channel 50x6 mm flat for 8 mtr 200kg psc pole [ non galvanized ] ( lxiii ) clamp for top channel 50x6 mm flat for tublar pole [ galvanized ] ( lxiv ) clamp for top channel 50x6 mm flat for tublar pole [ non galvanized ] ( lxv ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 60kg rail pole [ galvanized ] ( lxvi ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 60kg rail pole [ non galvanized ] ( lxvii ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 9 mtr 400kg psc pole [ galvanized ] ( lxviii ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 9 mtr 400kg psc pole [ non galvanized ] ( lxix ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 8 mtr 200kg psc pole [ galvanized ] ( lxx ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for 8 mtr 200kg psc pole [ non galvanized ] ( lxxi ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for tublar pole [ galvanized ] ( lxxii ) clamp for ab switch base channel ( 50x6 mm ) ( 1 set for 2 pair ) for tublar pole [ non galvanized ] ( lxxiii ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ galvanized ] ( lxxiv ) ms channel ( 75x40x6 mm ) for supporting h.g fuse & l.a [ non galvanized ] ( lxxv ) clamp ( 50 x 6 mm ) for transformer base channel [ galvanized ] ( lxxvi ) clamp ( 50 x 6 mm ) for transformer base channel [ non galvanized ] ( lxxvii ) clamp ( 50 x 6 mm ) for transformer belting [ galvanized ] ( lxxviii ) clamp ( 50 x 6 mm ) for transformer belting [ non galvanized ] ( lxxix ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] ( lxxx ) clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ non galvanized ] ( lxxxi ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 60kg rail pole [ galvanized ] ( lxxxii ) d.p channel support clamp ( 50x6 mm ) ) for 60kg rail pole [ non galvanized ] ( lxxxiii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 9 mtr 400kg psc pole [ galvanized ] ( lxxxiv ) d.p channel support clamp ( 50x6 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( lxxxv ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for 8 mtr 200kg psc pole [ galvanized ] ( lxxxvi ) d.p channel support clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ nongalvanized ] ( lxxxvii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ galvanized ] ( lxxxviii ) d p channel support clamp ( 50x6 mm ) feet ( 1 pair = 1 set ) for tublar pole [ non galvanized ] ( lxxxix ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ galvanized ] ( xc ) d p channel clamp ( 40x6 mm ) flat for 60 kg rail pole [ non galvanized ] ( xci ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ galvanized ] ( xcii ) d p channel clamp ( 40x6 mm ) flat 9 mtr 400kg psc pole [ non galvanized ] ( xciii ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ galvanized ] ( xciv ) d p channel clamp ( 40x6 mm ) flat 8 mtr 200kg psc pole [ non galvanized ] ( xcv ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ galvanized ] ( xcvi ) d p channel clamp ( 40x6 mm ) flat for tublar pole [ non galvanized ] ( xcvii ) 33kv cross bracing for d p structure [ galvanized ] ( xcviii ) 33 kv cross bracing for dp channel [ non galvanized ] ( xcix ) 11 kv cross bracing for d p structure [ galvanized ] ( c ) 11 kv cross bracing for d p structure [ non galvanized ] ( ci ) clamp for cross bracing set of 2 pair for 60kg rail pole [ galvanized ] ( cii ) clamp for cross bracing set of 2 pair for 60kg rail pole [ non galvanized ] ( ciii ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ galvanized ] ( civ ) clamp for cross bracing set of 2 pair for 9 mtr 400kg psc pole [ non galvanized ] ( cv ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole [ galvanized ] ( cvi ) clamp for cross bracing set of 2 pair for 8 mtr 200kg psc pole non [ galvanized ] ( cvii ) clamp for cross bracing set of 2 pair for tublar pole [ galvanized ] ( cviii ) clamp for cross bracing set of 2 pair for tublar pole [ non galvanized ] ( cix ) support clamp for cross bracing for 60kg rail pole [ galvanized ] ( cx ) support clamp for cross bracing for 60kg rail pole [ non galvanized ] ( cxi ) support clamp for cross bracing for 9 mtr 400kg psc pole [ galvanized ] ( cxii ) support clamp for cross bracing for 9 mtr 400kg psc pole [ non galvanized ] ( cxiii ) support clamp for cross bracing for 8 mtr 200kg psc pole [ galvanized ] ( cxiv ) support clamp for cross bracing for 8 mtr 200kg psc pole [ non galvanized ] ( cxv ) support clamp for cross bracing for tublar pole [ galvanized ] ( cxvi ) support clamp for cross bracing for tublar pole [ non galvanized ] ( cxvii ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ galvanized ] ( cxviii ) angle / side stay clamp ( 50x6 mm ) for 60kg rail pole [ non galvanized ] ( cxix ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ galvanized ] ( cxx ) angle / side stay clamp ( 50x10 mm ) for 9 mtr 400kg psc pole [ non galvanized ] ( cxxi ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ galvanized ] ( cxxii ) angle / side stay clamp ( 50x6 mm ) for 8 mtr 200kg psc pole [ non galvanized ] ( cxxiii ) angle / side stay clamp ( 50x6 mm ) for tublar pole [ galvanized ] ( cxxiv ) angle / side stay clamp ( 50 x 6 mm ) for tublar pole [ non galvanized ] ( cxxv ) clamp for g.i. pipe ( cxxvi ) ms flat ( 75x40x6 mm ) [ galvanized ] ( cxxvii ) ms flat ( 75x40x6 mm ) [ non galvanized ] ( cxxviii ) earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] ( cxxix ) earth clamp for earthwire ( 50 x 6 mm ) [ non galvanized ] ( cxxx ) ms angle for lt distribution bus ( 35x35x6 mm ) 1 set for 2 pair [ galvanized ] ( cxxxi ) ms angle for l t distribution bus ( 35 x 35 x6 mm ) [ non galvanized ] ( cxxxii ) lt bracket vertical formation ( cxxxiii ) lt bracket for tapping point ( cxxxiv ) lt angle bracket ( 35x35x6 mm ) [ galvanized ] ( cxxxv ) lt angle bracket ( 35 x 35 x 6 mm ) [ non galvanized ] ( cxxxvi ) ms flat 35x6 mm ( d ring ) for 10 connections [ galvanized ] ( cxxxvii ) ms flat 35x6 mm ( d ring ) for 10 connections [ non galvanized ] ( cxxxviii ) pole clamp for i hook b type ( cxxxix ) lt back clamp ( 50 x 6 mm ) for lt angle [ galvanized ] ( cxl ) lt back clamp ( 50 x 6 mm ) for lt angle [ non galvanized ] ( cxli ) u clamp ( 40 x 6 mm ) [ galvanized ] ( cxlii ) u clamp ( 40 x 6 mm ) [ non galvanized ] ( cxliii ) 50 x 6 mm galvanized gi flat ( risers ) ( cxliv ) 25 x 3 mm galvanized gi flat ( risers ) m1655 d.o. fuse ( i ) 11 kv d.o. fuse unit ( polymer type ) ( ii ) 33 kv d.o. fuse unit ( polymer type ) m1656 electrical conduit ( pipes ) ( i ) gi pipe 4 medium duty ( b class ) ( ii ) gi pipe 6 medium duty ( b class ) ( iii ) gi pipe 8 medium duty ( b class ) ( iv ) hume pipe rcc pipe 100 mm ( np2 class ) ( v ) hume pipe rcc pipe 150 mm ( np2 class ) ( vi ) hume pipe rcc pipe 200 mm ( np3 class ) m1657 heat shrinkable kit ( i ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 400 mm2 ( ii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 300 mm2 ( iii ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 240mm2 ( iv ) 33 kv 3 core xlpe ug cable heat shrinkable straight through jointing kit suitable for 185 mm2 ( v ) 33 kv termination kit for 1core x 400mm2 ( vi ) 11 kv termination kit for 3core x 630mm2 ( vii ) in door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( viii ) out door heat shrink type cable termination kit 11kv ht xlpecable 1cx 630 sqmm ( armoured ) ( ix ) lt xlpe 3 3.5 4 core heat shrinkable straight through cable jointing kit 400 mm2 ( x ) lt xlpe 3 3.5 4 core heat shrinkable straight through cable jointing kit 300 185 mm2 ( xi ) lt xlpe 3 3.5 4 core heat shrinkable straight through cable jointing kit 150 70 mm2 ( xii ) lt xlpe 3 3.5 4 core heat shrinkable straight through cable jointing kit 50 25 mm2 ( xiii ) lt xlpe 3 3.5 4 core heat shrinkable straight through cable jointing kit 4 16 mm2 ( xiv ) lt xlpe 3 3.5 4 core heat shrinkable indoor outdoor cable jointing kit 400 mm2 ( xv ) lt xlpe 3 3.5 4 core heat shrinkable indoor outdoor cable jointing kit 185 300 mm2 ( xvi ) lt xlpe 3 3.5 4 core heat shrinkable indoor outdoor cable jointing kit 70 150 mm2 ( xvii ) lt xlpe 3 3.5 4 core heat shrinkable indoor outdoor cable jointing kit 25 50 mm2 ( xviii ) lt xlpe 3 3.5 4 core heat shrinkable indoor outdoor cable jointing kit 4 16 mm2 m1658 ug cables related material ( i ) pillar box cum consumer service distribution box one time lock system ( 1 no. 3 ph 4 wire incoming and 5 nos. 3ph 4 wire outgoing ) ( ii ) cable marker ( metal ) m1659 ( ) ab switch contact ( i ) male female contact of 33 kv ab switch 600 630 amp ( ii ) male female contact of 33 kv ab switch 400 amp ( iii ) male female contact of 33 kv ab switch 200 amp ( iv ) male female contact of 11 kv ab switch 800 amp ( v ) male female contact of 11 kv ab switch 600 amp ( vi ) male female contact of 11 kv ab switch 400 amp ( vii ) male female contact of 11 kv ab switch 200 amp m1660 testing equipment ( i ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt whole current single phase meters up to 60a ( ii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh, kvarh and kvah maximum current up to 6a in direct mode and up to 500a in clamp on mode. lt+ : to test lt 3 phase & ct operated energy meters ( iii ) accuchek meter high accuracy ( 0.2% in director mode / 0.5% in clamp on mode ) for kwh for ht+ : to test meters suitable for ht, 3 phase, 3 wire and 4 wire systems ( iv ) eh ii chain electric hoist ( capacity 1 ton, standard lift 3 mtr ) with 1.5 hp motor ( v ) electronic weighing machine with 1.2x1.2 mtr. platform, suitable for weighing limit upto 2 tons ( vi ) electronic weighing machine with 2x2 mtr. platform, suitable for weighing limit upto 4 tons ( vii ) earth tester 200 amp. 2000 ohm ( digital ) ( viii ) 500 v megger ( ix ) 2.5 / 5 kv megger ( mannual ) ( x ) digital clamp meter ( meco 3150 ) ( xi ) digital tong tester ( 1000 amp., 500 v ) with associated accessories. ( xii ) digital multi meter ( 10 amp along with ma range ) ( xiii ) 2.5 kv motorised with range up to 20000 mega ohms ( xiv ) 2.5 kv motorised cum manual with range up to 20000 mega ohms ( xv ) 5 kv motorised with range up to 100000 mega ohms ( xvi ) 5 kv motorised cum manual with range up to 100000 mega ohms m1661 tool kit ( i ) adhesive insulation tape ( ii ) high temperature tape ( iii ) dicharge rod for 33 kv / 11kv ( iv ) screw driver set 840 ( v ) screw driver set 935 ( vi ) neon tester 813 ( vii ) hammer 200 gm ( viii ) hack saw frame ( ix ) hack saw blades ( x ) adjustable spanner ( xi ) wire stripper ( xii ) combinational plier ( xiii ) side cutting plier ( xiv ) measuring tape ( xv ) hand drill machine ( xvi ) punch ( xvii ) knife ( xviii ) spanner set ( xix ) tool bag ( xx ) nose plier ( xxi ) drill bit 3 / 10 concrete ( jk ) ( xxii ) chain pulley 5ton with 15 meter chain ( xxiii ) max pulley 10 ton m1662 civil works ( i ) opc cement ( ii ) earth work in excavation in foundation trenches ( along with disposal of excavated earth upto 50m, removing tree roots and shrubs ) ( for normal soil ) ( iii ) earth work in excavation in foundation trenches ( along with disposal of excavated earth upto 50m, removing tree roots and shrubs ) ( for rocky soil ) ( iv ) filling in foundation trenches and plenth in layers not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 m and lift of 1.5 m all complete as per building specification and direction of e / i ( v ) providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150 mm thick with all leads and lifts including cost of all material labor, royalty and taxes all complete as per building specification and direction of e / i” ( vi ) brick flat soling ( vii ) providing p.c.c.m 150 in nominal mix ( 1:2:4 ) in foundation with quality of stone chips 20mm to 6mm size graded and clean coarse sand of f.m 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as perbuilding specification and direction of engineer in charge ( viii ) providing p.c.c.m 100 in nominal mix ( 1:3:6 ) in foundation with quality of stone chips 20mm to 6mm size graded and clean coarse sand of f.m 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as perbuilding specification and direction of engineer in charge ( ix ) providing p.c.c.m 75 in nominal mix ( 1:4:8 ) in foundation with quality of stone chips 20mm to 6mm size graded and clean coarse sand of f.m 2.5 to 3 including screening shuttering mixing cement concrete in mixer and placing in position vibrating, striking, curing, taxes and royalty all complete as perbuilding specification and direction of engineer in charge ( x ) providing r.c.c.m 150 with nominal mix ( 1:2:4 ) in foundation and plinth and with quality stone chips 20mm to 6mm size graded and clean coarse sand of f.m. 2.5 to 3 incuding screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing ( but excluding the cost of reinforcement, taxed and royalty all complete, as per building specification and direction of e / i. ) m1663 ( ) scada related materials ( a ) scada server ( i ) fep server with interface switches for rtus and frtus ( ii ) isr server { data server } ( iii ) nms server { dms server } ( iv ) dts server ( only at ranchi ) ( v ) developmental server ( vi ) communication server ( vii ) web / directory server ( viii ) workstation with dual tft monitors ( ix ) led based video projection system with 2x3 module configuration with each module at least 67 diagonal with common projector ( x ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 1f ) ( xi ) 33 kv or 11 kv control and relay panel, scada compatable for transformer protection ( it ) with o / c +e / f + diff relay ( xii ) 33 kv or 11 kv control and relay panel, scada compatable for feeder protection ( 2f ) ( xiii ) buchholz relay contact ( xiv ) minimum oil gauge ( xv ) scada compatible winding temp. indicator ( xvi ) scada compatible oil temp. indicator ( xvii ) rtu base equipment comprising panels, racks, sub racks, powe suppy modules, cpu, analog and digital input control output modules, interfacing mft using rs 485 modbus protocol and 2 ethernet ports + 4 serial ports ( rs232 / 485 ) , required a d converters and all other accessories required ( xviii ) dc voltage transducer ( xix ) rtu base and foundation ( base should be capable of withstanding 200 kg. load ) ( xx ) multi function transducers ( 5 amps, 110 v with rs 485 modbus communication protocol ) ( xxi ) type a frtu for 5 way rmus ( xxii ) type a frtu for 4 way rmus ( xxiii ) type b frtu for 3 way rmus ( xxiv ) type c frtu for 2 way rmus ( xxv ) routers 230 v ac, 2 ge ports, 48xfe, wan speed 200 mbps ( xxvi ) ethernet switch ( xxvii ) 2 mbps vpn link for connectivity for s / s with scada control center ( xxviii ) ldms ( xxix ) 2 kva ups ( for ldms ) with 160 ah battery, 72 v battery set ( xxx ) 6 kva ups ( xxxi ) gsm / gprs modem along with accessories ( xxxii ) 5 kva ups ( xxxiii ) 12 u network rack ( xxxiv ) hp eio code ( xxxv ) interrupter ( xxxvi ) cmri 3phase ( xxxvii ) b / w laser printer for ldms ( xxxviii ) 48 v dc power supply system based on smps for rtu & comm. equipment with 80 ah battery ( xxxix ) cat 6 cable ( xl ) ldms software ( xli ) numerical relay scada compatible for power transformer protection ( xlii ) numerical relay scada compatible for 33kv and 11 kv feeder protection ( xliii ) mcu module card ( xliv ) power module card ( xlv ) di card ( xlvi ) do card ( xlvii ) ai card ( xlviii ) com 6 card ( xlix ) rmu 3 way ( 1 incomer, 1 outgoing and 1 breaker ) scada compatible ( l ) rmu 5 way ( 1 incomer, 1 outgoing and 3 breakers ) scada compatible ( li ) 11 kv sectionalizer ( lii ) 11 kv auto reclosure ( liii ) gprs / cdma / edge / 3g modem ( liv ) heavy duty relay for cb trip / close ( 48 v dc, 2 no, 1 nc ) ( lv ) 48 v dcps at rtu locations along with vrla batteries ( lvi ) 11 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( lvii ) 33 kv stand alone fault passage indicator complete with gprs enabled modem ( scada compatible ) ( b ) storage & backup devices ( i ) external raid mass storage device ( for 2 months online backup ) ( ii ) external dat drive ( c ) switches ( i ) layer ii switch ( scada / dms lan ) ( 48 ports ) ( ii ) layer switch ( planning & development system lan ) ( 24 ports ) ( d ) other active devices ( i ) gps time synchronization system ( ii ) time, day & date digital displays ( e ) printers ( i ) a3 color inkjet printer ( ii ) b / w laser printer ( iii ) color laser printer ( f ) security system ( dmz ) ( i ) web server with load balancing ( ii ) mail server ( 1+1 ) included in it system ( iii ) firewall & network ids / ips in pair ( 2 nos. ) ( g ) cabling system ( i ) cable, jacks, hubs, etc. ( ii ) acdb for control centre ( iii ) kvm switch ( iv ) panels ( h ) software for control centre ( i ) scada software ( ii ) isr software ( iii ) dms software ( iv ) dts software ( v ) developmental software ( vi ) network management software ( vii ) web / network security software ( included in it package ) ( viii ) rdbms package ( included in isr ) ( ix ) gis adaptor / engine for importing data from gis system under it system ( i ) form: f 4: rtu:rtu type b 33 / 11 kv sub stations ( i ) rtu base equipment comprising panels, racks, sub racks, power supply modules, cpu, analog and digital input control output modules, interfacing equipments for interfacing mfts using rs 485 modbus protocol and 2 eathernet ports, required a d converters & all other required items / accessories including complete wiring for all modules for locations mentioned for type b rtus ( ii ) multifunction transducers ( mfts ) ( iii ) contact multiplying relays ( cmrs ) ( iv ) heavy duty relays ( hdrs ) for cb trip / close and rise and lower of oltc ( v ) weather transducer wind speed ( vi ) weather transducer rainfall ( vii ) weather transducer humidity ( viii ) weather transducer temperature ( ix ) weather transducer wind direction ( x ) router for rtus at dc power supply ( xi ) oltc transducers ( xii ) dc current transducer ( xiii ) dc voltage transducer ( xiv ) acdb with sufficient mccbs ( j ) test equipments for rtu ( i ) rtu database configuration & maintenance software tool ( ii ) master station cum rtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( k ) form: f 5:frtu / frtus ( i ) mini frtu base equipment along with enclosuress suitable to work in open environment withadequate protection to water & dust, with racks, sub racks, power supply modulesi / o modules, cpu, interfacing equipments, required a d converters & all other required items / accessories including complete wiring for all modules for frtu locations. ( ii ) type a frtu for 5 way rmus ( iii ) type a1 frtu for 4 way rmus ( iv ) type b frtu for 3 way rmus ( v ) type c frtu for sectionalizers ( vi ) mfts ( vii ) contact multiplying relays ( cmrs ) ( viii ) heavy duty relays for cb trip / close ( l ) test equipments for frtu ( i ) frtu database configuration & maintenance software tool ( ii ) master station cum frtu simulator & protocol analyzer software tool ( iii ) laptop pc for above software tools along with interfacing hardware including hub ( m ) f4: gprs / cdma / edge / 3gmodems ( i ) gprs ( ii ) cdma for frtu locations + 3 at hub ( no back up to rtus allowed ) ( iii ) edge ( iv ) 3g ( n ) form: f 7: auxiliary power supply system ( aps ) ( i ) 20 kva ups ( 1+1 ) with vrla batteries to give 4 hrs back up ( ii ) dc power supply ( dcps ) system based on smps ( for 20 a load plus charging current@10% capacity ) with vrla batteries to give 4 hrs back up. ( iii ) 10 kva ups ( 1+1 ) with vrla batteries to give 4 hrs back up ( iv ) dc power supply ( dcps ) system based on smps ( for 20 a load plus charging current@10% capacity ) with vrla batteries to give 4 hrs back up. ( v ) 2 kva ups for rtu locations / ldms ( vi ) 48 v dcps at rtu locations along with vrla batteries ( vii ) 24 / 48 v dcps for frtu locations along with vrla batteries ( o ) cards for rtu and frtu ( i ) mcu 1 a module card of rtu ( ii ) mcu 4 a module card of rtu ( iii ) comm module card of rtu ( iv ) power module card of rtu ( v ) di card of rtu ( vi ) do card of rtu ( vii ) ai card of rtu ( viii ) mcu module card of frtu ( ix ) power module card of frtu ( x ) di card of frtu ( xi ) do card of frtu m1664 safety equipment ( i ) rechargeable led hand torch ( ii ) safety helmet pvc ( iii ) safety shoes ( electrical safety ) ( iv ) rubber hand gloves ( 1.1kv ) commander ( v ) safety double adjustable belts ( karam ) ( vi ) safety items as per the requirement of electrical inspector as under first aid box, shock treatment chart, rubber matts 8 mm thick, 4 fire buckets with sand & m.s. hooks / stand, helmet, hand gloves and, fire extinguisher ( 2 nos ) m1665 fire extinguishers ( i ) i kg dry chemical powder ( map 50% ) ; fire rating : 1a, 8b ( ii ) 2 kg dry chemical powder ( map 50% ) ; fire rating: 2a, 8b ( iii ) 4 kg dry chemical powder ( map 50% ) ; fire rating : 2a, 21b ( iv ) 6 kg dry chemical powder ( map 50% ) ; fire rating: 3a, 34b ( v ) 9 kg dry chemical powder ( map 50% ) fire rating: 4a, 55b ( vi ) 6 ltr water type; fire rating : 2a 1 2 ( vii ) 9 ltr water type, fire rating: 3a ( viii ) 6 ltr mechanical foam type, fire rating: 2a, 21b ( ix ) 9 ltr mechanical foam type, fire rating: 4a, 34b ( x ) 2 kg carbon dioxide type, fire rating: 8b ( xi ) 3 kg carbon dioxide type, fire rating: 13b ( xii ) 4.5 kg carbon dioxide type, fire rating: 21b ( xiii ) 6.5 kg carbon dioxide type, fire rating: 55b ( xiv ) 9 kg carbon dioxide type, fire rating: 70b ( xv ) 22.5 kg carbon dioxide type, fire rating: 70b ( xvi ) gas pressure ctc fire extinguisher ( xvii ) fire buckets ( capacity 10 ltrs. ) m1666 ( ) feeder pillar / smdb / distribution board ( i ) lt mini feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) ( ii ) smdb ( 1 in, 3 out ) with housing 5 nos 20 amp spn mcb, ( iii ) tpn distribution board 12 way, 50 amp tpn mcb, ( iv ) tpn distribution board 12 way, 100 amp tpn mcb, ( v ) tpn distribution board 12 way, 150 amp tpn mcb, ( vi ) lt feeder piller box for 1 phase 8 connection made of m.s.sheet. ( vii ) lt feeder piller box for 1 phase 12 connection made of m.s.sheet. ( viii ) lt feeder piller box for 3 phase 4 connection made of m.s.sheet. ( ix ) lt feeder piller box for 3 phase 8 connection made of m.s.sheet. ( x ) lt feeder pillar ( simple with fuse arrangement ) ( aluminium bus ) m1667 ( a ) aluminium end terminal ( i ) 10 sq mm ( ii ) 225 sq mm m1668 other misc. equipment ( i ) earthing g.i.strip ( 65x6 ) mm2 ( ii ) rain coat ( iii ) rubber mat along length of pannel ( iv ) aluminium pipe 40 mm dia ( v ) 400 watt / 250 v hpsv lamp fitting complete for 33 / 11 kv pss yard lightining ( vi ) 30 v 80 ah battery charging unit complete with battery and stand ( vii ) 30 volts 100 ah lead acid battery with battery charger and stand ( viii ) 30v, 40 amp. float cum boost battery charger with full wave rectification for 230 v, 1 phase, 50 hz ac input supply as per technical specifications. ( ix ) polycarbonate seal bit ( x ) sticker seal with hologram ( xi ) earth knob ( xii ) ms earth mat for switch yard ( xiii ) rail piece 44.64kg / m 6.92 meter long for power transformer ( xiv ) aluminium binding wire ( xv ) gi wire no. 6 / 8 / 10 ( xvi ) t / c fuse wire 12 / 14 / 16 / 18 / 22 / 28 / 32 swg ( xvii ) m s nuts & bolts of different size ( xviii ) galvanised nuts & bolts ( assorted size ) ( xix ) jointing sleeves ( alumnium ) suitable for 34 / 55 sq.mm ( xx ) jointing sleeves ( alumnium ) suitable for 70 100 sq.mm ( xxi ) jointing sleeves ( alumnium ) suitable for 150 232 sq.mm ( xxii ) anticlimbing device ( barbed wire ) 2x12 swg ( xxiii ) al paint ( xxiv ) red oxide paint ( xxv ) lt phase seperator ( xxvi ) 3 mm thick ms plate with weight of 0.36 kg asset tag ( xxvii ) transformer oil ( ehv grade ) ( xxviii ) natural ester oil ( xxix ) c wedge connector for 0.2sq panther conductor ( nominal aluminum area 200mm2 ) ( xxx ) fault locator machine for ug cables ( flc ) without vehicle ( xxxi ) transformer oil testing kit ( 220 / 230 ac ) ( xxxii ) transformer oil filter machine ( 500 gph ) ( b ) furniture ( i ) godrej thrive mid back revolving chair size:75cm ( w ) x 75cm ( d ) x 100cm 109cm ( h ) x 45cm 54cm ( seat height ) . ( ii ) godrej thrive non revolving visitor chair size:63.5cm ( w ) x 59.5cm ( d ) x 97.5cm ( h ) x 42.5cm ( seat height ) . ( iii ) godrej regency non revolving visitor chair with armrest size:59cm ( w ) x 63cm ( d ) x 81.5cm ( h ) x 45cm ( seat height ) . ( iv ) godrej regency mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 78.5cm 90.5cm ( h ) x 44.2cm 54.2cm ( seat height ) . ( v ) godrej bravo mid back revolving chair size:76.3cm ( w ) x 76.3cm ( d ) x 85.5cm 97.5cm ( h ) x 42.5cm 54.5cm ( seat height ) . ( vi ) godrej la sede high back revolving chair size:76.1cm ( w ) x 76.1cm ( d ) x 114.5cm 131.5cm ( h ) x 44.5cm 54.5cm height ) . ( vii ) godrej la sede non revolving visitor chair size:60.9cm ( w ) x 64.7cm ( d ) x 98.2cm ( h ) x 46.2cm ( seat height ) . ( viii ) godrej halo very high back revolving chair size:77cm ( w ) x 77cm ( d ) x 134.9cm 143.9cm ( h ) x 49.9cm 58.9cm ( height ) . ( ix ) godrej halo non revolving visitor chair size:59cm ( w ) x 68.5cm ( d ) x 89.5cm ( h ) x 46.5cm ( seat height ) . ( x ) godrej unlearn single seater cpu / laptop table for computer training hall size: 90cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xi ) godrej unlearn 2 seater laptop table for meeting hall size:135cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xii ) godrej unlearn 4 seater laptop table for meeting hall size:270cm ( w ) x 60cm ( d ) x 68cm ( h ) ( xiii ) godrej talk unitised 4 seater round table size:120cm dia x 75cm ( h ) ( xiv ) godrej talk modular conference table size:67.5cm ( w ) x 60cm ( d ) x 75cm ( h ) ( xv ) godrej enterprise table with cpu hanger size:165cm ( w ) x 90cm ( d ) x 72.8cm ( h ) ( xvi ) godrej insight table for library size:180cm ( w ) x 90cm ( d ) x 74cm ( h ) ( xvii ) godrej versatila v2 table for faculty sitting area size:150cm ( w ) x 89.4cm ( d ) x 75cm ( h ) ( xviii ) godrej aristo executive table with right unit and pedestal size:180cm ( w ) x 210cm ( d ) x 75cm ( h ) ( xix ) godrej impress main desk table size: 180cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xx ) godrej impress back unit for impress desk table size: 221.5cm ( w ) x 41cm ( d ) x 200cm ( h ) ( xxi ) godrej display unit tv cabinet walnut color size: 140cm ( w ) x 40cm ( d ) x 75.4cm ( h ) ( xxii ) godrej time out 4 seater pu coated dining table size: 113.5cm ( w ) x 117.5cm ( d ) x 75cm ( h ) ( xxiii ) godrej unwind café chair without armrest size: 52.5cm ( w ) x 55.8cm ( d ) x 84.5cm ( h ) x 45cm ( seat height ) ( xxiv ) godrej neo apple dining table 6 seater glass top size: 160cm ( w ) x 90cm ( d ) x 75cm ( h ) ( xxv ) godrej novice silver dining chair size: 44.5cm ( w ) x 41.5cm ( d ) x 96cm ( h ) ( xxvi ) godrej grande dark walnut dining chair size: 45cm ( w ) x 45cm ( d ) x 95cm ( h ) ( xxvii ) godrej alice coffee table walnut color size: 100cm ( w ) x 65cm ( d ) x 45cm ( h ) ( xxviii ) godrej pisa 3 seater leatherite sofa size: 205.5cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxix ) godrej pisa 2 seater leatherite sofa size: 100cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxx ) godrej pisa single seater leatherite sofa size: 86cm ( w ) x 92cm ( d ) x 82cm ( h ) ( xxxi ) godrej storwel plain almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxii ) godrej glass door storwel almirah size: 91.6cm ( w ) x 48.6cm ( d ) x 198cm ( h ) ( xxxiii ) godrej single sided wood & steel book rack base unit size:90cm ( w ) x 30cm ( d ) x 189cm ( h ) ( xxxiv ) godrej all steel periodical display rack size:90cm ( w ) x 45cm ( d ) x 183cm ( h ) ( xxxv ) godrej 4 door bookcase ( without top ) size:91.4cmw x 32cm ( d ) x 174.2cm ( h ) ( xxxvi ) white board 4ft. x 3ft. with stand ( xxxvii ) l shaped workstation made of 19mm thk white mdf board with pvc edges. ( xxxvii ) size:1800mm ( l ) + 1200mm ( l ) x 600mm ( d ) x 1200mm ( h ) ( c ) led tv ( i ) supply, installation, testing and commissioning of 75 ultra hd led television with all accessories. ( ii ) make : sony / samsung / lg ( iii ) supply, installation, testing and commissioning of 32 hd led television with all accessories. ( iv ) make : sony / samsung / lg ( d ) projector & screen set complete ( i ) supply, installation, testing and commissioning of full hd projector with all accessories like bracket, ceiling mount kit powder coated for projector, 4x6, 16:9 aspect ratio, motorised projection screen etc.make : epson / canon / panasonic ( e ) split type air conditioners set complete ( i ) supply, installation, testing and commissioning of 1.5tr split ac inverter type 3 star rating with ms frame, copper pipe, drain pipe etc.. complete with all accessories like 5kva stabiliser, wiring etc.make: voltas / daikin / mitsubishi / hitachi / lg / samsung ( ii ) supply, installation, testing and commissioning of 2tr split ac inverter type 3 star rating with ms frame, copper pipe, drain pipe etc.. complete with all accessories like 5kva stabiliser, wiring etc.make: voltas / daikin / mitsubishi / hitachi / lg / samsung ( f ) water purifier cum cooler set complete ( i ) supplying, installing, testing & commissioning of water purifier cum cooler of following specifications: make : bluestar / eurak forbes / voltas / zero b / kentstorage tank : 150 litersno.of faucets 2nett weight in kg ( approx ) 95 kgdimensions : 812mm ( w ) x 612mm ( d ) x 1210mm ( h ) refrigerant : r 22current in amps : 8.0type of compressor : rotarycooling capacity 150litres per hourwater tank sheet material and thickness stainless steel ( grade aisi 304 ) with puf insulation, thickness > =0.6 mmwater tank cover and lid bottom sheet material high impact polystrene ( hip ) water tank cover and lid bottom sheet thickness 1.5 millimetercooler cabinet sheet material stainless steel ( grade aisi 304 ) cooler cabinet sheet thickness 0.8 millimeter ( g ) sound system set complete ( i ) supply, installation, testing & commissioning of sound system ( make: ahuja / bose ) set consisting of following items: i ) amplifier with 5 independent channels and can provide automatic re settable overcurrent, overload, overheating, overvoltage, under voltage and dc protection 4 nos.ii ) 6w ceiling speaker with max spl1m / 1w 96db . frequency response of 80hz 20khz with a dispersion angle of 160 deg 16 nos.iii ) 30w wall mount with max spl1m / 1w 96db . frequency response of 160hz 20khz 12 nos.iv ) 2 x 1.5 sq mm armoured frls cable 1000 mtsv ) wireless microphone system 2 nos.vi ) tabletop wireless microphone 64 nos. meter box ( i ) poly carbonate weather proof outdoor type meter cover boxes for single phase meter size 315mm x 265mm x 130mm along with zinc plated clamps ( ii ) poly carbonate weather proof outdoor type meter cover boxes for three phase meters 445mm x 345mm x 170mm along with zinc plated clamps ( iii ) deep drawn m.s. sheet weather proof outdoor type meter cover box for single phase meter size 300mm x 250mm x 160mm along with zinc plated clamps ( iv ) deep drawn m.s. sheet weather proof outdoor type meter cover box for three phase meter size 500mm x 300mm x 160mm along with zinc plated clamps ( v ) metal box of ct 800 / 5 amp ( vi ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 400 / 5a ( vii ) meter box ( viii ) meter box made of m / s sheet etc. crca metal sheet each fitted with 4no. racing cost ct ratio 800 / 5a ( ix ) metal box of ct 400 / 5 amp gas insulated switchgear s / s ( i ) 30kv, 10ka, metal oxide, station class, surge arrester ( scada compliant ) ( for 33kv incoming line, ht side of 2nos. power transformers and 33 / 0.433kv station transformer ) outdoor type with surge counter. ( ii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) with: breaker: 36kv, 1250 a, ( 25ka s.c. rating ) , 3 ph, indoor type breaker ( with 30v dc tripping / closing coil and associated control ) along with marshalling box, terminal connectors and required accessories complete as per applicable ts ct:36kv, 1 ph, 25ka ( 800^00 200 / 1 1 1 a ) indoor type current transformer, having three secondary cores ( protection & metering & current differential protection ) along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set = 3 nos. ) pts: 36kv, 1 ph, 33kv / 110 v, single core outdoor type potential transformer along with terminal connectors, junction box and required accessories etc. complete as per applicable ts ( 1 set= 3 nos. ) and digital ammeter / voltmeter / energy meter, o / c and e / f relay etc. the cable chamber shall have 3 nos., 20kv, 10 ka distribution class valve type lightning arresters and isolators of capacity given in ts. for feeder protection 1 2 ( iii ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between gis and indoor control panel required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter static vector energy meter, relays and accessories complete for bus coupler protection. ( iv ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 1a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between breakers and indoor control and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter tri vector energy meter, relays and accessories complete for power transformer protection. ( v ) 33kv indoor gas insulated switchgear panel ( scada compliants ) consisting of 36 kv breaker 630a, 25 ka for 3 sec, phase single busbar 1250a ( copper ) , 36 kv single phase, ( 800 400 200 / 1 1 1a ) 3 nos of indoor type cts, 33 kv / 110volts potential transformers, indoor mounting type control panel, control cabelling between breakers and indoor control and required accessories, bi metalic clamps, ammeter , voltmeter, modem compatible dlms compliant class 1 meter tri vector energy meter, relays and accessories complete for station transformer protection. ( vi ) 11 kv indoor gas insulated switch gear panel ( scada compliants ) consisting of 1250 a, 25ka for 3 seconds, 3 ph, indoor type breaker along with 12 kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for transformer protection ( vii ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, indoor mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for bus coupler protection ( viii ) 12 kv, 1250 a, 25ka for 3 seconds, 3 ph, indoor gas insulated switch gear panel ( scada compliants ) along with kv, 1 phase, 600 300 / 1 1 1 1 amp 3 nos indoor type current transformer, 11 kv / 110 volts potential transformers, mounting type control panel for transformer breaker, control cabling between breaker and indoor control panel and required accessories, bi metallic clamps, a meter, volt meter, modem compatible dlms complaint class a static tri vector energy meter, relay & accessories complete for feeder protection ( ix ) remote terminal unit ( rtu ) & accessories with pc & connections with 30 nos. analog points for voltage, frequency, mw, mvar ; 3 positional analog points for oltc and 28 digital points for breaker and isolator status. ( x ) flexible cu. earth bond 1cm dia & 500mm long, both end provision of socket suitable for m 16 bolts. ( xi ) g 3 gi beam ( 5.05mtr long, consisting of 2 nos 150x75 x5.7mm ) for 33kv incoming line ( 2 nos. beam one for arrester and other for isolator, nominal unit wt 0.2 mt ) ( xii ) gi spikes with cone and gi ( 2 nos ) base plate 10mm ( 50x2500 mm gi pipe ) ( unit wt=0.04 mt ) ( xiii ) 12 kv, 630 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , gang operated isolator along earth switch and support insulators, operating mechanism, base channel, down pipe and all required accessories complete as per technical specifications, without earth switch for substation transformers. ( xiv ) 60 kg / mtr rail pole pieces 5.4 mts ( 2.7x2 ) 44.62 kg per mtr / transformer ( unit wt=0.240 mt ) ( xv ) 2 tier 2 rows cable trench ( internal width 1500 mm, depth 680 mm, width 75x75x6 mm support angles fixed rcc column of 250 x 250 mm & with ladder type cable tray ( 45x45x5mm two angles at both side having welded flats of mm at a gap of 150mm ) for power & control cable ( xvi ) chequerred plate 1000x300x5.6mm thick for cable trench in side control room 12 mtr ( xvii ) overhead hoist beam mounted remote opertated for lifting of equipment of control room, capacity 5 tonnes ( xviii ) 36kv, 800 a, 25ka for 3 seconds, 3 ph double break centre rotating type ( dbcr ) , motorised indoor floor mounted off load isolator along with all required accessories complete as per technical specifications, scope of works and approved ( xix ) external electrification in switch yard area including power receptacles, station yard lighting with 6 nos lighting ( fitted with 2x100 watts led flood light ) made of 11 meters high steel tubular poles ( is 2713 part i, ii iii ) of designation 410 – sp 60 and 6 nos light ( 1 x 250 w led ) on structure & control room complete as per technical specifications, approved drawings and scope of the work. ( xx ) internal electrification works of control room comprising of main distribution board, sub distribution boards, flexible multi conductor 2.5 sqmm wiring ( for light & fan ) / 4 sqmm wiring ( for power points ) , power and light points, conduits, fan / led lamps / tube fittings, exhaust fans, switches, sockets, 2mm thick, pvc 25mm dia conduits pipes in plugs, miniature circuit breakers, seperate independent earthing ( 2 nos of 40mm gi pipe / 3 m long ) etc as required including dc emergency lighting and auto change over switch as per technical specifcations, approved drawings and of work. m1671 ( ) over head distance to fault locator ( offline ) with signature analyser. a ) accessories & laptop as per latest technical specifications m1672 ( ) tower line for river crossings ( i ) d type tower for 33kv, 11kv ( double circuit line ) ( 13.56mt each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( ii ) d type tower for 33kv, 11kv ( four circuit line ) ( 15.14mt ) ( double circuit tower +3meter extension each ) with all related nuts and bolts including foundation nuts and bolts ( g i type ) ( iii ) compression type tension hardware fitting for earth wire ( iv ) vibration damper suitable for 7 / 3.15 mm gi earth wire ( v ) 25x500 mm flexible cu. earth bond. m1673 covered conductor & accessories ( i ) acsr covered panther conductor ( 200 sq. mm ) ( ii ) acsr covered wolf conductor ( 150 sq. mm ) ( iii ) acsr covered dog conductor ( 100 sq. mm ) ( iv ) mid span joint ( 150 sq mm & 200 sq mm ) ( v ) suspension ties ( ( 150 sq mm & 200 sq mm ) ) ( vi ) tension clamp ( wedge type ) ( ( 150 sq mm & 200 sq mm ) ) ( vii ) insulation piercing connector ( bare to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( viii ) insulation piercing connector ( covered to covered ) ( ( 150 sq mm & 200 sq mm ) ) ( ix ) insulation piercing connector with alumunium bail for earthing ( ( 150 sq mm & 200 sq mm ) ) ( x ) mid span joint ( 100 sq mm & 50 sq mm ) ( xi ) suspension ties ( ( 100 sq mm & 50 sq mm ) ) ( xii ) tension clamp ( wedge type ) ( ( 100 sq mm & 50 sq mm ) ( xiii ) insulation piercing connector ( bare to covered ) ( 100 sq mm & 50 sq mm ) ( xiv ) insulation piercing connector ( covered to covered ) ( 100 sq mm & 50 sq mm ) ( xv ) insulation piercing connector with aluminium bail for earthing ( 100 sq mm & 50 sq mm ) m1674 led lights and related items ( i ) led light 190w ( ii ) led light 120w ( iii ) led light 75w ( iv ) led light 40w ( v ) 18 watt led panel bulb with outer 205x205x25 mm sq. and 180x180 mm inner m1675 diesel generator sets ( three phase ) with amf panel ( i ) 10kva ( ii ) 20kva ( iii ) 30kva ( iv ) 40kva ( v ) 50kva ( vi ) 62.5kva ( vii ) 82.5kva ( viii ) 100kva ( ix ) 160kva m1676 trw related items ( i ) 1 / 2 l.t. brass studs ( ii ) 1 / 2 h.t. brass studs ( iii ) l.t bushing 3347 250 amp ( iv ) l.t. bushing 250 amp ( v ) kraft paper 4 mile ( vi ) insulating paper tap 2.0 mm ( vii ) press board 1 mm ( viii ) bakelite tube 3 / 8x1 / 2 ( ix ) empire sleeving size 4 mm ( x ) r.c. sheet 3 x2x1 / 2 mm ( xi ) inline connector 6 mm ( xii ) cotton tap 1 ( xiii ) r.c. strip ( xiv ) r.c. washer 50x28x2 ( xv ) silicagel breather 200 kva ( xvi ) m.seal ( xvii ) c.i.cap 1 8 1 / 2 ( xviii ) insulating paper top 2.5 mil 20 mm ( xix ) crap paper ( xx ) g.p. thinner ( xxi ) d.a. gray paint ( xxii ) white paint ( xxiii ) nylon washer 3 / 4 ( xxiv ) m.s. plug ( xxv ) l.t. al.strip 6.50x4.50 mm m1677 transformer repairing items ( i ) l.t bushing rod assembly of 750 kva transformer. ( ii ) h.t bushing rod assembly of 750 kva transformer. ( iii ) l.t bushing insulator of 750 kva transformer. ( iv ) h.t bushing insulator of 750 kva transformer. ( v ) l.t bushing gasket set of 750 kva transformer. ( vi ) h.t bushing gasket set of 750 kva transformer. ( vii ) tank gasket set of 750 kva transformer. ( viii ) silica gel breather of 750 kva transformer. ( ix ) arching horn of 750 kva transformer, ( x ) l.t bushing rod assembly of 500 kva transformer ( xi ) h.t bushing rod assembly of 500 kva transformer ( xii ) l.t bushing insulator of 500 kva transformer ( xiii ) h.t bushing insulator of 500 kva transformer ( xiv ) l.t bushing gasket set of 500 kva transformer ( xv ) h.t bushing gasket set of 500 kva transformer ( xvi ) tank gasket set of 500 kva transformer ( xvii ) silica gel breather of 500 kva transformer ( xviii ) arching horn of 500 kva transformer ( xix ) l.t bushing rod assembly of 400 kva transformer ( xx ) h.t bushing rod assembly of 400 kva transformer ( xxi ) l.t bushing insulator of 400 kva transformer ( xxii ) h.t bushing insulator of 400 kva transformer ( xxiii ) l.t bushing gasket set of 400 kva transformer ( xxiv ) h.t bushing gasket set of 400 kva transformer ( xxv ) tank gasket set of 400 kva transformer ( xxvi ) silica gel breather of 400 kva transformer ( xxvii ) arching horn of 400 kva transformer ( xxviii ) l.t bushing rod assembly of 315 kva transformer ( xxix ) h.t bushing rod assembly of 315 kva transformer ( xxx ) l.t bushing insulator of 315 kva transformer ( xxxi ) h.t bushing insulator of 315 kva transformer ( xxxii ) l.t bushing gasket set of 315 kva transformer ( xxxiii ) h.t bushing gasket set of 315 kva transformer ( xxxiv ) tank gasket set of 315 kva transformer ( xxxv ) silica gel breather of 315 kva transformer ( xxxvi ) arching horn of 315 kva transformer ( xxxvii ) l.t bushing rod assembly of 250 kva transformer ( xxxviii ) h.t bushing rod assembly of 250 kva transformer ( xxxix ) l.t bushing insulator of 250 kva transformer ( xl ) h.t bushing insulator of 250 kva transformer ( xli ) l.t bushing gasket set of 250 kva transformer ( xlii ) h.t bushing gasket set of 250 kva transformer ( xliii ) tank gasket set of 250 kva transformer ( xliv ) silica gel breather of 250 kva transformer ( xlv ) arching horn of 250 kva transformer ( xlvi ) l.t bushing rod assembly of 200 kva transformer ( xlvii ) h.t bushing rod assembly of 200 kva transformer ( xlviii ) l.t bushing insulator of 200 kva transformer ( xlix ) h.t bushing insulator of 200 kva transformer ( l ) l.t bushing gasket set of 200 kva transformer ( li ) h.t bushing gasket set of 200 kva transformer ( lii ) tank gasket set of 200 kva transformer ( liii ) silica gel breather of 200 kva transformer ( liv ) arching horn of 200 kva transformer ( lv ) l.t bushing rod assembly of 100 kva transformer ( lvi ) h.t bushing rod assembly of 100 kva transformer ( lvii ) l.t bushing insulator of 100 kva transformer ( lviii ) h.t bushing insulator of 100 kva transformer ( lix ) l.t bushing gasket set of 100 kva transformer ( lx ) h.t bushing gasket set of 100 kva transformer ( lxi ) tank gasket set of 100 kva transformer ( lxii ) silica gel breather of 100 kva transformer ( lxiii ) arching horn of 100 kva transformer ( lxiv ) l.t bushing rod assembly of 63 kva transformer ( lxv ) h.t bushing rod assembly of 63 kva transformer ( lxvi ) l.t bushing insulator of 63 kva transformer ( lxvii ) h.t bushing insulator of 63 kva transformer ( lxviii ) l.t bushing gasket set of 63 kva transformer ( lxix ) h.t bushing gasket set of 63 kva transformer ( lxx ) tank gasket set of 63 kva transformer ( lxxi ) silica gel breather of 63 kva transformer ( lxxii ) arching horn of 63 kva transformer ( lxxiii ) l.t bushing rod assembly of 25 kva transformer ( lxxiv ) h.t bushing rod assembly of 25 kva transformer ( lxxv ) l.t bushing insulator of 25 kva transformer ( lxxvi ) h.t bushing insulator of 25 kva transformer ( lxxvii ) l.t bushing gasket set of 25 kva transformer ( lxxviii ) h.t bushing gasket set of 25 kva transformer ( lxxix ) tank gasket set of 25 kva transformer ( lxxx ) silica gel breather of 25 kva transformer ( lxxxi ) arching horn of 25 kva transformer ab switch repairing item ( i ) jaw of air break switch 600a ( ii ) blade of of air break switch 600a ( iii ) post insulator of air break switch 600a ( iv ) bearing of air break switch 600a ( v ) phase coupling pipe of air break switch 600 a ( vi ) down pipe of air break switch 600 a ( vii ) operating handle of air break switch 600 a ( viii ) operating leaver of air break switch 600 a ( ix ) connector of air break switch 600 a ( x ) arching horn of air break switch 600 a ( xi ) jaw of air break switch 400a ( xii ) blade of of air break switch 400a ( xiii ) post insulator of air break switch 400a ( xiv ) bearing of air break switch 400a ( xv ) phase coupling pipe of air break switch 400 a ( xvi ) down pipe of air break switch 400 a ( xvii ) operating handle of air break switch 400 a ( xviii ) operating leaver of air break switch 400 a ( xix ) connector of air break switch 400 a ( xx ) arching horn of air break switch 400 a ( xxi ) jaw of air break switch 200a ( xxii ) blade of of air break switch 200a ( xxiii ) post insulator of air break switch 200a ( xxiv ) bearing of air break switch 200a ( xxv ) phase coupling pipe of air break switch 200 a ( xxvi ) down pipe of air break switch 200 a ( xxvii ) operating handle of air break switch 200 a ( xxviii ) operating leaver of air break switch 200 a ( xxix ) connector of air break switch 200 a ( xxx ) arching horn of air break switch 200 a vcb repairing item ( i ) trip coil of 33kv vcb ( ii ) trip coil of 11kv vcb ( iii ) closing coil of 33kv vcb ( iv ) closing coil of 11kv vcb ( v ) push button switch 5a ( vi ) test terminal block 5a ( vii ) 33 kv indoor current transformers of ratio as required suitable for metering and protection. ( viii ) 33 kv outdoor current transformers of ratio as required suitable for metering and protection. ( ix ) 11 kv indoor current transformers of ratio as required suitable for metering and protection. ( x ) 11 kv outdoor current transformers of ratio as required suitable for metering and protection. ( xi ) 33000 / 110 volts single phase voltage transformer indoor. ( xii ) 33000 / 110 volts single phase voltage transformer outdoor. ( xiii ) 11000 / 110 volts single phase voltage transformer indoor. ( xiv ) 11000 / 110 volts single phase voltage transformer outdoor. ( xv ) flush type switchboard mounting pattern 96x96 sq.mm m.i. voltmeter ( xvi ) voltmeter phase selector switch. ( xvii ) indicating lamps coloured red, amber and blue, white, green, etc. ( xviii ) auxiliary switch having minimum of 8 contacts, 4 normally open and 4 normally closed ( xix ) flush mounting pattern 96x96 sq.mm m.i. ammeter ( xx ) ammeter selector switch to indicate phase current ( xxi ) over current and earth fault numerical relay ( xxii ) automatic door illuminating lamps with switch ( xxiii ) 240 v, 100 w, ac single phase anti / condensation heaters, with thermostat ( 0 60 deg. c ) and switch. ( xxiv ) operation counter for vcb ( xxv ) bus bar spout epoxy casted r phase of 33kv indoor vcb ( xxvi ) bus bar spout epoxy casted y phase of 33kv indoor vcb ( xxvii ) bus bar spout epoxy casted b phase of 33kv indoor vcb ( xxviii ) circuit spout epoxy casted of 33kv indoor vcb ( xxix ) housing for vacuum interrupter of 33kv indoor vcb ( xxx ) drive insulator 33kv vcb ( xxxi ) release coil of 33kv indoor vcb ( xxxii ) bus bar spout epoxy casted r phase of 11kv indoor vcb ( xxxiii ) bus bar spout epoxy casted y phase of 11kv indoor vcb ( xxxiv ) bus bar spout epoxy casted b phase of 11kv indoor vcb ( xxxv ) circuit spout epoxy casted of 11kv indoor vcb ( xxxvi ) housing for vacuum interrupter of 11kv indoor vcb ( xxxvii ) drive insulator of 11kv vcb ( xxxviii ) release coil of 11kv indoor vcb ( xxxix ) vacuum interrupter of 33kv outdoor type ( xl ) vacuum interrupter of 33kv indoor type ( xli ) vacuum interrupter of 11kv outdoor type ( xlii ) vacuum interrupter of 11kv indoor type ( xliii ) buzzer / hooter ( xliv ) t n c switch m1680 mrt related items ( i ) fully automatic energy meter test bench with 0.02 class, 10 position, for testing of 1 ph & 3 ph energy meters ( ii ) 3 ph energy meter test kit field testing of 3 ph energy meters comprising of portable reference meter and portable power source ( iii ) 1 ph energy meter test kit for field testing of 1 ph energy meter ( iv ) instrument transformer ( ct pt ) test system ( v ) dc winding resistance measurement test kit rating 25 a ( vi ) acdc hipot test kit 5kv ( vii ) transformer turn ratio meter and measurement test kit ( viii ) oil breakdown value ( bdv ) test kit 80kv ( ix ) transformer oil filtering machine 600 lph ( x ) earth tester with all necessary accessories ( xi ) circuit breaker operational analyzer ( xii ) 3 ph relay test kit with all necessary accessories ( xiii ) digital micro ohm meter measurement test kit ( xiv ) primary injection kit 1000 a with relay testing facility ( xv ) ct polarity tester ( xvi ) tong tester: 2000 a ac / dc ( xvii ) electro mechanical tool kit ( xviii ) hv gloves ( xix ) capacitance tan delta test set for transformer, motor and switchgear ( xx ) capacitance tan delta test set for cables ( xxi ) vaccum interrupter tester ( xxii ) secondary injection kit ( xxiii ) digital ht earth tester ( xxiv ) 3 ph power quality analyser ( xxv ) 05 kv insulation tester ( manual ) ( xxvi ) 10 kv insulation tester ( motarized ) ( xxvii ) digital clamp meter; 20 1000a, 200 v dc ( xxviii ) digital clamp meter; 20a ( 1ma 20a ) ( xxix ) discharge rod ( xxx ) thermal imaging camera m1681 frp fencing ( i ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 63kva substation ( ii ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 100 kva substation ( iii ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 200 kva substation ( iv ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 315 kva substation ( v ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 400kva substation ( vi ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 500 kva substation ( vii ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 630 kva substation ( viii ) fiber reinforced plastic ( frp ) fencing for 11 / 0.433kv, 750 kva substation...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

23753708 supply of 1 gi earthing pipe 3.1 meter long (40 mm dia) 2 aluminium pipe 40 mm dia 3 earthingg.i.strip for (65x6) 4 earthing (chemical) with gi earthing pipe 40 mm 3.1 mtrs. long (bentonite as intermittent layers) 5 earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long 6 earth clamp for earthwire (50 x 6 mm)[galvanized]...

Jharkhand State Electricity Board - Jharkhand

23729232 supply of earthing related materials , electrical items : , gi earthing pipe 3 . 1 meter long ( 40 mm dia ) , aluminium pipe 40 mm dia , earthing g . i . strip for ( 65x6 ) , earthing ( chemical ) with gi earthing pipe 40 mm 3 . 1 mtrs . long ( bentonite as intermittent layers ) , earthing ( chemical ) with gi earthing pipe 20 mm 2 . 5 mtrs . long , earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] ...

Jharkhand State Electricity Board - Jharkhand

15931890 supply of electric line materials 1 33 kv dp channel (100 x 50 x 6 mm) 1.3 meter long (galvanized) 2 33 kv back clamp for line dp channel, rail pole (galvanized) 3 33 kv dp channel support clamp (50 x 6 mm) rail pole (galvainzed) 4 33 kv back clamp for top bracket rail pole (galvanized) 5 11 kv back clamp for line dp channel (galvanized) 6 11 kv dp channel support clamp (50 x 6 mm) (galvanized) 7 11 kv dp channel (100 x 50 x 6 mm) 1.3 meter long (galvanized) 8 clamp (50 x 6 mm flat) for top channel (galvanized) 9 clamp (50 x 6 mm ) for ab switch base channel (galvanized) 10 clamp (50 x 6 mm) for transformer base channel (galvanized) 11 clamp (50 x 6 mm) for transformer belting (galvanized) 12 clamp (50 x 6 mm) for lt bus & h.g. fuse set (galvanized) 13 back clamp for (50 x 6 mm) for 60 kg. rail pole (galvanized) 14 support clamp for v cross arm for 60 kg. rail pole (galvanized) 15 back clamp for (50 x 6 mm) jointing/ packing piece for 60 kg. rail pole (galvanized) 16 33 kv angle stay clamp (50 x 5 mm) (galvanized) 17 anticlimbing device (barbed wire) 18 stay clamp side/angle (50 x 10 mm) 19 angle/ side stay clamp (50 x 6 mm) for 8 mtr. 200 kg. psc pole (galvanized) 20 earth clamp for earthwire (50 x 6 mm) (galvanized) ...

Jharkhand State Electricity Board - Jharkhand

15339358 supply of electric line materials, 407 / pr / jbvnl / 2017 18 1 33 kv dp channel (100 x 50 x 6 mm) 1.3 meter long (galvanized) 2 33 kv back clamp for line dp channel (galvanized) 3 33 kv dp channel support clamp (50 x 6 mm) (galvainzed) 4 33 kv back clamp for top bracket (galvanized) 5 11 kv back clamp for line dp channel (galvanized) 6 11 kv dp channel support clamp (50 x 6 mm) (galvanized) 7 11 kv dp channel (100 x 50 x 6 mm) 1.3 meter long (galvanized) 8 clamp (50 x 6 mm flat) for top channel (galvanized) 9 clamp (50 x 6 mm ) for ab switch base channel (galvanized) 10 clamp (50 x 6 mm) for transformer base channel (galvanized) 11 clamp (50 x 6 mm) for transformer belting (galvanized) 12 clamp (50 x 6 mm) for lt bus & h.g. fuse set (galvanized) 13 back clamp for (50 x 6 mm) for 60 kg. rail pole (galvanized) 14 support clamp for v cross arm for 60 kg. rail pole (galvanized) 15 back clamp for (50 x 6 mm) jointing/ packing piece for 60 kg. rail pole (galvanized) 16 33 kv angle stay clamp (50 x 5 mm) (galvanized) 17 anticlimbing device (barbed wire) 18 stay clamp side/angle (50 x 10 mm) 19 angle/ side stay clamp (50 x 6 mm) for 8 mtr. 200 kg. psc pole (galvanized) 20 earth clamp for earthwire (50 x 6 mm) (galvanized)...

Jharkhand Bijli Vitran Nigam Limited - Jharkhand

14102964 supply of 33 kv angle stay clamp (50 x 6 mm) (galvanized), 11 kv angle stay clamp (50 x 10 mm) (galvanized) , angle/side stay clmap (50x6 mm) for 8 mtr 200 kg psc pole (galvanized), earth clamp for earthwire (50x6 mm) (galvanized), support clamp for v cross arm for 60kg rail pole (galvanized), support clamp for 11 kv v cross arm (galvanized), 33 kv d.p. channel support clamp (50 x6 mm) (galvanized),11 kv d.p. channel support clamp (50 x 6 mm) (galvanized),ms base plate for 33 kv, ms flat (75x40x6 mm) (galvanized), ant climbing device (barbed wire)...

Jharkhand State Electricity Board - Jharkhand

14046042 adp line materials, 266 / pr / jbvnl / 2017 18 1 33 kv v cross arm (100x50x6 mm) (galvanized) 2 33 kv pole top bracket for 60kg rail pole (galvanized) 3 11 kv v cross arm (75x40x6 mm) (galvanized) 4 11 kv pole top bracket 50 x8 mm flat (galvanized) 5 clamp (50x6 mm flat) for top channel (galvanized) 6 clamp (50x6 mm) for ab switch base channel (galvanized) 7 clamp (50x6 mm) for transformer base channel (galvanized) 8 clamp (50x6 mm) for transformer belting (galvanized) 9 clamp (50x6 mm) for lt bus & hg fuse set (galvanized) 10 33 kv back clamp for top bracket (galvanized) 11 33 kv back clamp for line dp channel (galvanized) 12 11 kv back clamp for v cross arm (galvanized) 13 11 kv back clamp for top bracket (galvanized) 14 11 kv back clamp for line dp channel (galvanized) 15 back clamp (50x6 mm) for 60kg rail pole (galvanized) 16 back clamp (50x6 mm)jointing/packing piece for 60kg rail pole (galvanized) 17 stay clamp side/angle (50x10 mm) 18 33 kv angle stay clamp (50 x 6 mm) (galvanized) 19 11 kv angle stay clamp (50 x 10 mm) (galvanized) 20 angle/side stay clmap (50x6 mm) for 8 mtr 200 kg psc pole (galvanized) 21 earth clamp for earthwire (50x6 mm) (galvanized) 22 support clamp for v cross arm for 60kg rail pole (galvanized) 23 support clamp for 11 kv v cross arm (galvanized) 24 33 kv d.p. channel support clamp (50 x6 mm) (galvanized) 25 11 kv d.p. channel support clamp (50 x 6 mm) (galvanized) 26 ms base plate for 33 kv 27 ms flat (75x40x6 mm) (galvanized) 28 anticlimbing device (barbed wire) s...

Jharkhand State Electricity Board - Jharkhand

14045659 adp line materials, 266 / pr / jbvnl / 2017 18 1 33 kv v cross arm (100x50x6 mm) (galvanized) 2 33 kv pole top bracket for 60kg rail pole (galvanized) 3 11 kv v cross arm (75x40x6 mm) (galvanized) 4 11 kv pole top bracket 50 x8 mm flat (galvanized) 5 clamp (50x6 mm flat) for top channel (galvanized) 6 clamp (50x6 mm) for ab switch base channel (galvanized) 7 clamp (50x6 mm) for transformer base channel (galvanized) 8 clamp (50x6 mm) for transformer belting (galvanized) 9 clamp (50x6 mm) for lt bus & hg fuse set (galvanized) 10 33 kv back clamp for top bracket (galvanized) 11 33 kv back clamp for line dp channel (galvanized) 12 11 kv back clamp for v cross arm (galvanized) 13 11 kv back clamp for top bracket (galvanized) 14 11 kv back clamp for line dp channel (galvanized) 15 back clamp (50x6 mm) for 60kg rail pole (galvanized) 16 back clamp (50x6 mm)jointing/packing piece for 60kg rail pole (galvanized) 17 stay clamp side/angle (50x10 mm) 18 33 kv angle stay clamp (50 x 6 mm) (galvanized) 19 11 kv angle stay clamp (50 x 10 mm) (galvanized) 20 angle/side stay clmap (50x6 mm) for 8 mtr 200 kg psc pole (galvanized) 21 earth clamp for earthwire (50x6 mm) (galvanized) 22 support clamp for v cross arm for 60kg rail pole (galvanized) 23 support clamp for 11 kv v cross arm (galvanized) 24 33 kv d.p. channel support clamp (50 x6 mm) (galvanized) 25 11 kv d.p. channel support clamp (50 x 6 mm) (galvanized) 26 ms base plate for 33 kv 27 ms flat (75x40x6 mm) (galvanized) 28 anticlimbing device (barbed wire)...

Jharkhand State Electricity Board - Jharkhand

13431988 supply of electric line materials (i) clamp (50 x 6 mm flat) for top channel [galvanized] (set of 2 pair) (ii) clamp (50 x 6 mm) for ab switch base channel [galvanized] 1 set = 2 pair (iii) stay clamp side/angle (50 x 10 mm) [galvanized] (iv) clamp (50 x 6 mm) for transformer base channel [galvanized] 1 set = 2 pair (v) clamp (50 x 6 mm) for transformer belting [ galvanized] (vi) clamp (50 x 6 mm) for lt bus & h.g fuse set [ galvanized] (vii) earth clamp for earthwire (50 x 6 mm) [galvanized] (viii) 11 kv back clamp for top bracket [galvanized] (ix) 11 kv back clamp for v cross arm [galvanized] (x) 11 kv d.p channel support clamp (50x6 mm) [galvanized] (xi) 33 kv back clamp for top bracket [galvanized] (xii) back clamp ( 50x6 mm) for 60kg rail pole[galvanized] (xiii) support clamp for v cross arm for 60kg rail pole[galvanized] (xiv) packing piece for 60kg rail pole [galvanized] (xv) 33 kv angle stay clamp (50 x 6 mm) [galvanized] 1 set = 1 pair (xvi) 33 kv d.p channel support clamp (50x6 mm) [galvanized] (xvii) earth clamp for earthwire (50 x 6 mm) [galvanized] for rail pole (xviii) earthing g.i.strip for (65x6) (xix) angle/side stay clamp ( 50x6 mm) for 8 mtr 200kg psc pole[galvanized]...

Jharkhand State Electricity Board - Jharkhand

13272418 tender for supply of electric line materials : 1 clamp ( 50 x 6 mm flat ) for top channel [ galvanized ] 2 stay clamp side / angle ( 50 x 10 mm ) 16 3 earth clamp for earthwire ( 50 x 6 mm ) [ galvanized ] 4 11kv top channel 5 ms angle for l t distribution bus 6 clamp ( 50 x 6 mm ) for lt bus & h.g fuse set [ galvanized ] 7 ms flat ( 75x40x6 mm ) [ galvanized ] 8 structure for 33kv lightening arrestor [ galvanized ] 9 gantry column, girder structures 10 a structures for top mounted ab switch on 11 kv & 33 kv bus [ galvanized ] 11 structure for 33 kv pt [ galvanized ] 12 structure for 33 & 11 kv isolator [ galvanized ] 13 structure for post insulator for 33kv [ galvanized ] 14 earthing g.i. strip for ( 65x6 ) 15 33 kv pole top bracket 16 33 kv back clamp 17 33 kv v cross arm 18 back clamp 19 support clamp 20 back clamp 21 33 kv angle stay clamp 22 33 kv d.p channel support clamp etc....