Power Grid Corporation Of India Limited - Jharkhand
39809586 bids are invited for custom bid for services rectification of sag of earth wire in 400kv jamshedpur tisco baripada line...
39809586 bids are invited for custom bid for services rectification of sag of earth wire in 400kv jamshedpur tisco baripada line...
38481894 erection of earth wires for providing earth continuity in 6.6 kv feeders (05 and 06), 3.3 kv feeder (09 and 12) from new sub station and old sub station respectively to the sumps and mines of kdh ocp, nk area...
38480800 tender for erection of earth wires for providing earth continuity in 6.6 kv feeders (05 and 06), 3.3 kv feeder (09 and 12) from new sub station and old sub station respectively to the sumps and mines of kdh ocp, nk area....
38317438 erection of earth wires for providing earth continuity in 3.3kv fd no. 10 from old ss to subhash nagar officer club and 11kv fd from old ss to kd old colony and providing and fixing of lightening arrestor in 3.3kv and 11kv ht oh line of kdh ocp...
38223378 erection of poles, drawing of conductor and earth wire of 3.3kv overhead line for quarry feeder for day to day works as and when required in gidi c colliery under argada area ....
37371859 internal and external electrification work of mandal kara at chas in the district of bokaro ( 1 ) pvc insuleted copper conductor wire of make 2 1.3 point wiring in pvc conduit, with modular type switch: wiring for light point / fan point / exhaust fan point / call bell point with 1.5. sq.mm fr pvc insuleted copper conductor single core cable in recessed pvc conduit, with modular type switch, pheonlic lamineted sheet, suitable size g.i.box etc. 3 1.3.3group c 4 1.7circuit / submain wiring in pvc conduit: wiring for circuit / submain wiring along with earth wire with the following size pvc insuleted copper conductor single core cable in recessed pvc conduit as required 5 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire 6 1.7.114x10.0 sq mm+2x6.0 sq mm earth wire 7 1.24s / f modular type switch / socket : supplying and fixing following modular type switch box / cover including connections but excluding modular plate etc as required 8 1.24.15 / 6 amps, one way switch 9 1.24.45 / 6amps, 3 pin socket outlet 10 1.33s / f ceiling rose: supplying and fixing 2 pin 5 amp, ceiling rose on the existing junction box / wooden block including connection etc as required. 11 1.35errection on incandescent light fitting: errection of wall bracket / ceiling fitting, complete with all accessories including connection etc as required. 12 2.9s / f t.p.mcb db: supplying and fixing following way three pole and nutral, sheet, mcb distribution board, 415 volt, in recess, complete with tinned copper busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 13 2.9.56 way ( 4+18 ) , double door, horizontal type 14 2.11s / f b series. s.p.mcb: supplying and fixing 6 amps to 32 amps rating, 240 volts, b series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting mcb db complite with connections. testing and commisioning etc as required. 15 2.11.16 / 32 amps, single pole, b series 16 2.12s / f c series. s.p.mcb: supplying and fixing 6 amps to 32 amps rating, 240 volts, c series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting mcb db complite with connections. testing and commisioning etc as required. 17 2.12.16 / 32 amps, single pole, c series 18 2.12.1050 / 63 amps, tpn etc...
37342736 fitting of lighting arrester, providing and fitting of earth wire and other miscellaneous work at 1k pit, jarlahi, sahana and budora substation of phularitand, amp colliery....
36940907 tender for supply of materials 1.aluminum binding wire 2.earth clamp for earth wire (50 x 6 mm) [galvanized] 3.pg clamp for 100 sq. mm conductor 4.pg clamp for 80 sq.mm 5.male female contact of 11 kv ab switch 600 amp 6.gi wire no.8 7.ms nuts & bolts of different size...
36466621 (a) replacement of old conventional earth pits by chemical earth pits of electric sub stations, supply and erection of continuous earth wire of ht oh line with chemical earth pits at a distance of approximately 250 meter distance between poles of ht...
36350992 provision of path light in the civil court campus at hazaribagh. s.i.t.c of following rating led post top lamp made in die cast aluminium housing with decorative clear / opal serylic diffuser onexisting pipe including connection with 1.5sq.mm. copper conductor etc all complete as required. 2 40 / 45w led post top lamp clear 3 making pcc ( 1:2:4 ) foundation plinth size of 1.5 x 1.5 x 2 ( .30 m x .30 m x .45 m ) with 6 raised pcc structure for grouting of pole for pathway light / garden light etc. i / c the cost of plastering c.m. ( 1:3 ) & two coat painting on raised structure including the cost of all labour and materials etc. as reqd. 4 supplying and laying of xlpe insulated pvc sheathed aluminium armoured cable working voltage upto 1100 volts as per is: 7098 ( part i ) of following size 5 a ) 2 core 6 sq.mm 6 wiring for circuit submain wiring along with earth wire with the following size pvc insulated copper conductor , single core cable in surface / recessedpvc conduit etc as reqd . 7 a ) 3x1.5 sq mm 8 supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 ka, “b” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, esting and commissioning etc. as required. 9 earthing with g.i. earth pipe 4.5 mtr long . 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. 10 supply and laying 8 swg copper wire at 0.50 metre below ground level for conductor earth electrode, including soldingetc. as required. 11 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. 12 s / f cable junction box 13 s / f 40mm medium class g.i. pipe for stable of streetlight on roof aand cable laying in road crossing 14 s / f tubular g.i. pole in three section ( medium class ) 100mm 1 mtr, 80mm 1 mtr, and 65mm 1mtrincluding fabrication welding charge, 2 coat primer and aluminium paint etc. all complete as reqd. 15 providing and fixing following dp / tp&n sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuse, including drilling holes in metal board. making connections etc as reqd. 16 a ) 32 amps, double pole 17 6 sq mm aluminium lugs...
36099242 supply & fitting of electrical materials with new earth wire, wiring of machine point, all switch board, fan regulators fitting, switch & socket fitting, led bulb and led tube light fitting of area laboratory and area sales office under mugma area....
36046998 supply, erection and commissioning of earthing system at panchet dam area for dam lighting and other electrical equipment supply & erection of earthing with 40 mm dia. & 3 metre long ms rod, including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with alternate layers of charcoal and salt as required at four ( 4 ) locations in the downstream side of panchet dam ( as per drawing in annexure i ) . [ two no. of earth pits ( dimension 300mm x 300mm x 3m ) are to be provided at each end of the cocrete portion of the dam having 4m minimum distance between them, so as to keep the value of earth resistance minimum ] . 2 downstream side of dam including approach road of power house & colony except the concrete portion: supplying and laying 25 mm x 3mm gi strip at minimum 0.25 metre below ground level for conductor earth electrode, including connection / termination with gi thimble etc. as required at each lighting pole of downstream side of dam except the concrete portion ( total 150 no. of poles & approximate length of path is 6.0 km ) [ laying of gi strip will be carried out as per proposed picture in annexure ii, excavation of soil, refilling & compression of the same, cutting of cemented drain & repairing of the same with proper finish after laying of strip is under the scope of agency ] . 3 upstream side & concrete dam: supplying and laying 25 mm x 3mm gi strip on parapet wall at upstream side & both side of concrete dam as per schematic attached in annexure iii ( a & b ) as strip earth electrode, including connection / termination with gi thimble etc. as required at each lighting pole / jb ( total 120 no. of poles & approximate length of path is 5km ) . clamping of gi strip is to be done at parapet & concrete wall at an interval of 1m with 200mm x 2mm gi strip. connection of earth strip of concrete area with the running earth strip at both end of concrete area to form the closed loop network. 4 connection between running earthing strip and lighting poles ( 270 no. ) : supplying of materials and providing connection between running earthing gi strip and each lighting poles ( 270 no. ) through welding and clamping ( as required to fix tightly ) by 25 mm x 3mm gi strip [ required length of gi strip for each pole is 1.5 mtr. ( approx. ) ] 5 providing earthing to 270 no. of lighting fixtures: connecting the earth wire of the fixture to the gi strip of each pole by 8 swg gi wire through a tb at existing jb. ( supply& fixing of the tb & 8 swg gi wire with gi thimble etc. properly ensuring tightness will be under the scope of agency ) . 6 supply, laying & termination of 25 mm x 5mm gi earth strip from nearest running gi earth strip for providing double earthing to 15 no. of crest gate local control panels, 15 no. of lt motors, two no. of bus bar panels, four no. of lighting panels & one no. of remote control panel located at control room near concrete dam at downstream side. proper termination with clamping and bolting at each end has to be provided as required. [ maximum distance of equipment from the running earth strip will be 5m ] 7 providing road crossing at each end of the dam by 25 mm x 3mm gi earth strip through 40mm dia. ms pipe ( length approx. 6m. ) at depth 0.25m so as to form a close loop of earthing network [ road crossing should be close to the end poles. excavation of road for laying of ms pipe, repairing & finishing of road after laying of ms pipe and allied works will be under the scope of agency ] . 8 painting of lighting poles: painting of lighting poles with one coat of red oxide and two coats of synthetic enamel paint of approved brand upto required even shed [ colour white ] . supply of paint under scope of agency. cleaning and surface preparation for painting under scope of agency. numbering of poles has to be done as previous. => limited...
35909471 day to day bassis new installation of earth pit and connection with 4 sq mm copper earth wire for different type of quaters at staff colony,russian colony,cpp colony ,mrs colony,mq colony,gayatri colony,teachers colony and hospital colony under g...
35908724 day to day bassis new installation of earth pit and connection with 4 sq mm copper earth wire for different type of quaters at staff colony,russian colony,cpp colony ,mrs colony,mq colony,gayatri colony,teachers colony and hospital colony under g m unit kathara...
35679111 providing and fixing of lightening arrestor at end point in 3.3kv pump feeder and preparation of earth pit for connecting lightening arrestor, earth wire and starter to ground at 32 no. sump under dakra project, n k area....
35652664 miscellaneous works like fabrication work of gi metal sheet covered shed for 03 nos. of starter and 01 nos. of transwitch unit and erection of earth wire for maintaining earth continuity and cradle guard in overhead lines under purnadih ocp nk area...
35532715 tender for provision medical store office at mh ramgarh surface excavation notexceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as specified and directed. 2 add to ( or deduct from ) above itemno. 1 for every 3cm or part there of above or below 15 cm average depth complete all as specified and directed. 3 excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient forlaying cables / pipes, foundations, laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. 4 returning, filling in including spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by engineer in charge. 5 removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by engineer in charge at a level not exceeding 1.5 m above the starting point complete all as specified. 6 m&l for plain cement concrete 1:4:8 type d 2 ( using 40 mm gradedcrushed stone aggregate ) as in sub base of flooring, foundations, filling & mass concrete for fencing posts, foundation of pole , struts & stay assembly etc complete all as specified and directed. 7 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in foundation including rafts, footings, plinth beams, and mass concreteetc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 8 m& lfor use & wasteof form work to sides of concrete foundation, base of coloumn , rafts, footings, plinth beams, andplinth beamand similar work for rough finished flat surfaces of concrete complete all as specified and directed. 9 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as incolumns, pillars, piers, popst and struts etc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 10 m& lfor use and waste of form work to sidesof columns, pillars, piers, post and struts for rough finished surface of concrete complete all as specified and directed. 11 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 12 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in lintels beam, floor / roof beams, cantilevers, bressummers, , etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 13 m&l reinforced cement concrete m 25 ( design mix ) ( using20 mm gradedcrushedstoneaggregate ) as in chajja etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 14 m& lfor use and waste of form work to sidesof soffit ofchajja, chullah hoods, troughs & similaritemsetc includingfor rough finished surface of concrete complete all as specified and directed. 15 m& lfor use and waste of form work to sidesofsoffit ofsuspended slab such as roof slab , floor slab , landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. 16 m& lfor use and waste of form work to sidesandsoffit oflintel beam, floor / roof beams, etcfor rough finished surface of concrete complete all as specified and directed. 17 use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. 18 m&l for brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed. 19 m&l for halfbrick thick brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. 20 m&l for with moorum / red bajri fillingunder the floor not exceeding 100 mm thick spreaded, levelled and rammed including watering complete allas specified & directed . 21 m&l forpre constructionantitermite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 22 m&l forpre constructionantitermite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of verticalsurface ( area of the sub structure in contact with backfill to be measured ) complete allas specified & directed . 23 m&l forpre constructionantitermite treatment for treating the the top surface of filledat the rate of5 litres of emulsion per square metre of surfacecomplete allas specified & directed . 24 m&l forpre constructionantitermite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 25 s & f brass4 screw plate drawer pulls, plate with fixed dished pull; 80 mm to 100mmlong complete all as spcefied and directed 26 s & f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with ms square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by engr in charge . 27 s & f for factory made solid panel pvc door shutter 30mm thick ( style ) consisting of frame made out of ms tube for top and bottom rails. ms framed shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour pvc sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour pvc sheet to be fitted in the ms framed welded / sealed to stiles & rails with suitable pvc sheet beading & joined together with solvent cement complete all asfixing in the frame at site as per specification and drawing including 3 nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed. 28 s&f 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed. 29 s & f 100mm sizebutt hinges medium weight cold rolled mild steel complete all as specified and directed . 30 s&f 150mm extruded aluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 31 s&f 150mmaluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 32 s&f of aluminium mortice lock, vertical type, size 75 mm four levers ( isi marked ) for aluminium doorscomplete all as specified and directed. 33 s&f 65 mm , four lever brasslocks, drawer, grade i of size 65 mmcomplete all as specified and directed. 34 s&ffloor door stopper of aluminium alloy body& tounge, 150 mm , anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 35 s&f brass4 screw drawer plate with fixed dished pull; 80 mm to 100mm longcomplete all as specified and directed. 36 s&ffloor double action spring hinges, brass with phosphor bronze wire spring, bright polished of size 100 mm complete all as specified and directed. 37 m & l for 18 / 19 mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timberframe work complete all as specified and directed. 38 s&f 40mm dia, brass , cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed. 39 s&fbrass handles 150mm size cast type , polished brightcomplete all as specified and directed. 40 m&l for mild steel tmt bars 10mm dia and over grade fe 500, cut to length, bent to shape required, including cranking bending spirally for hooping for column, , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 41 m&l for mild steeltmt bars 08 mm dia and over grade fe 500 , asin stirrups, spacers & binders , cut to length, bent to shape required, including cranking bending spirally for hooping for column, , hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 42 m&l for hard core of broken stone or bouldergauge not exceeding 63mm deposited, spread & leveled in layers not exceeding15cm thick, watered and rammed to a true surface etccomplete all as specified& directed. 43 m & l for 75 mm thick plain cement concrete ( 1:3:6 ) mix, type c 1 ( using 20mm graded crushedstone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85 / 25 gradeand sand in the ratio 1:3 including necessary form work , complete all as specified and directed. 44 m & l joint free non skid coloured ceramic tiles 7 to 8 mm thick ( sqaure / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar ( 1:4 ) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed. 45 m & l glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm / 450 mmx 300 mm x7 mm thick, as in dado / skirting etc , set and jointed in neat cement slurry and pointed in colour cement to match the tiles including 10 mm thickrendering in cement plaster in cm ( 1:3 ) , complete all as specified and directed. 46 m&l for vetrifieddark shed coloured ceramicfloor tiles10 mm thick ( square / rectangular ) area of each tileexceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar ( 1:6 ) etc complete all as specified &directed. 47 m&l for vetrifieddark shed ceramic tiles 10 mm thick ( square / rectangular ) area of each tilenot exceeding 0.36 sqmon vertical surface such as skirting / dado etc , set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar ( 1:4 ) etc complete all as specified & directed. 48 m&l for rendering 10 mm thick on brick masonry / concrete surface etc in cm ( 1:6 ) surface finished even & smooth using extra cement complete all as specified and directed. 49 m&l for rendering 15 mm thick on other than fair face brick masonry / concrete surface etc in cm ( 1:4 ) surface finished even & smooth using extra cement complete all as specified and directed. 50 m & l for rendering 5 mm thick in cm 1:4 on concrete surfaces as in ceilingfinished even and faircomplete all as specified and directed. 51 m&l for preparation of newly plastered surfaceof wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 52 m&l for preparation of newly plastered surface of ceilingand applying two coats of oil emulsion distemper over a coat of primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 53 m&l for preparation of newly plastered surfaceof externalwall andapplying two coatacrylicexterior emulsion paint of required shade over and including priming coat of exterior primer and a layer of putty ( not less than 1.5 mm thick ) complete all as specifiedand directed. 54 s &f powder coated aluminium work for doors, windows, ventilators shutters ( fixed / sliding track two or three track ) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle, c.p. brass / stainless steel screws, all complete all as specified and directed. 55 s&f powder coated aluminiumsliding door shutters ( minimum thickness of powder coating 50 micron ) , aluminium section weighing 0.55 kg / m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long ( 1no. ) , 100mm long hinges type b 21 ( 2nos ) , suitable handle ( 02 nos. ) in each door top rail guide rail etc. complete all as specified and directed. 56 &f powder coated aluminiumwindow and ventilatorshutters ( minimum thickness of powder coating 50 micron ) , fixed typewithout sash baraluminium section weighing 0.55 kg / m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings complete all as specified and directed. 57 s&ffor anodised aluminium grillsfor windows and ventilatoraluminium sections ( weightnot less than 2.25 kg / sqm ) size4mmx4mm, 8mm thick and aperture not exeeding 80 mmx 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tintcomplete all as specified and as directed. 58 s&f 5.5 mm thick sheet glass not exceeding 0.5 sqm ineach pane of superior quality fixed to aluminium frame work with rubber neoprene beadingincluding solar control film 50 micron reflective type sticked to glasspanes as per instructions of manufacturers completeall as specified & directed. 59 s&f 4 mm thick figured glass pin headed type in squares / rectangularnot exceeding 0.5 sqm ineach pane glazing with oil putty or aluminium frame / shutters with rubber neoprene beadingcomplete etc all as specified & directed. 60 s&f for gi water tubing mediumgrade, isi marked, galvanised, 15 mm bore with all fittings, ( such as tee, elbow, socket, union & short pieces ) fixed to walls and ceiling or laid in floors including cutting chasees for brick wallsand making good the surface in cement mortar 1:3 complete all as specified & directed. 61 s&f for gi water tubing mediumgrade, isi marked, galvanised, 25 mm bore with all fittings, ( such as tee, elbow, socket, union & short pieces ) fixed to walls / laid in trenches and ceiling or laid in floors including cutting chasees for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. 62 s&f rotational moulded polythene water storage tank of capacity 1000 ltrs ( cylindrical / vertical with closed type ) , triple layer construction, isi marked, hoisted and fixed in position including 20 mm bore gi nipple and20 mm bore ball / float valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed ( minimum weight 210 gms ) complete all as specified and directed. 63 s&f 20 mm borebrass ball / float valves high pressure with polythene float & fly nutcomplete all as specified and directed. 64 s&f bib taps long body, cast copper alloy with capstan head or butter fly handle, chromium platedfancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified &directed. 65 s&f fancy type angle stop valve fancy type chromium plated with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15 mm bore complete all as specified &directed. 66 s&f pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered hot or cold with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed. 67 s&f for pvc connection 15 mm dia size with ptmt nuts of length 450 mmcomplete all as specified and directed. 68 s&f 75 mm bore pvc ( swr ) pipes single socketed , in any length with rubber ring joints, laid in trenches , floor or inwall complete all as specified and directed. 69 m&l for 75mm pvc ( swr ) floor trap, plain with grating including jointing with solvent cementwithchromium platedgratingwith or without hole complete all as specified and directed. 70 s & f600mm x 450 mm bevelled edge looking mirror of selected quality glass mounted on 6 mm thick pvc sheet with pvc frame and fixed to wooden plugs with cp brass screw and cup washers complete all as specified and directed. 71 s & f pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, pvc flush pipe 32 mm bore & pvc connection 15 mm bore 450 mm long with ptmt nuts and brackets complete set all as specified anddirected. 72 s & f vitreous china wash basin, any colour, flat back size 550 mm x 400mm including 32mm brass chromium platedwaste coupling , pvc 32 mm bore waste pipe, chromium plated gratingincluding bracket complete all as specified and directed. 73 m&l for pcc 1:2:4 type b 1 ( using 20mm graded crushed stone aggregates ) in kerbs or mud stops, rounded or chamfered on edges water troughs and the like including necessary form workcomplete all as specified and directed. 74 m & l for 15 mm thick screed bed in cement mortar 1:4 mixedwith usingliquid water proofing compoundas per manufacturers instructionsover roof top surface finished even and smooth using extra cement and application of water proofing treatment using app modified roof membrane over existing non accessible / non approachablercc roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed : ( a ) cleaning existing surface properly. ( b ) applying approved bituminousbased primer @ 0.30 litre / sqm manufactured by the same agency as that of app membrane with a density 0.87 0.89 kg per liter at 25 degree centigrade on prepared surface &hot blown grade bitumin85 / 25 @ 1.2 kg / sqm over primer . ( c ) laying not less than 3mm thick app modified water proofing membrane weighing not less than 3.00 kg / sqm reinforced with non woven polyster fiber weight not less than 160gsm / sqm using butane torch by torch application with 10cm side laps and 15cm end lap. physical property of membrane shall be as under : ( i ) membrane weight not less than 3.00 kg / sqm. ( ii ) non woven polyester weight not less than 160 gsm / sqm. ( iii ) softening point of membrane not less than 150degree celsius. ( iv ) joint tensile strength longitudinal not less than 650 kg / sqcm and transverse not less than 450 kg / sq.cm at230 degree celsius. ( v ) tear strength longitudinal not less than 300 n& transverse not less than 250n. ( vi ) elongation of reinforcement not less than 30%. ( vii ) impermeability under water pressure not less than 3 kg / sqcm. ( d ) app membrane shall be laid using butane torch by torch application with minimum 10cm side overlap and 15cm end lap. ( e ) applying two coat of bituminiousbased aluminium paint @ 0.3 kg / sqm over app membrane. ( note:water proofing compound shall be measured and paid seprerately under respective item of boq ) 75 supply only liquid water proofing compound complete all as specified and directed. 76 m&l for 60mm thick factory mademachine pressed pre cast concrete coloured interlocking paver blockof approved shade of any shape and size conforming to is 15658 2006 of m 35 grade laid over &including cleaned dry sand cushion bed 50mm thick over &including 100 mm thick pcc 1:4:8 type d 2 ( using 40mm graded crushed stone aggregate ) assub base, surface finished even and rough over and including 75mm thick hardcore of broken boulder of gauge n exc. 63mm, deposited, spread and levelled, watered and rammed to a true surface, etc complete all as specified and directed. 77 m & l for 100 mm thick concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type d 2 ( using 40 mm gradedcrushed stone aggregate ) complete all as specified & directed. 78 m & l for 150 mm bore ( internal dia ) reinforced concrete drain pipe , class np 3, laid and jointedin trenches complete all as specified & directed. 79 m&l for plain cement concrete 1:3:6 type c 2 ( using 40 mm gradedcrushed stone aggregate ) as in foundations, bed of manhole , filling & mass concrete etc complete all as specified and directed. 80 m&l for plain cement concrete 1:2:4, type b 1 ( using 20 mm graded crushed stone aggregates ) as in surface channels / benching of manhole , drain , laid to shape and slopeand surface finished even & smooth using extra cement complete all as specified and directed 81 s& f 25 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 82 m&l for drilling in existing water pipe, taking new tapping from existing pipe, proper welding to the pipe surface complete all as specified and directed 83 s& f towel ring of ptmt fixed with and including chromium plated brassscrews and wooden / plasticcleats ( minimum weight 90 gms ) complete all as specified and directed 84 s&f vitreous china wash down water closet ( pedestal pattern ) , white ( excluding fixing bolts, flushing cistern and flush pipe ) , fixing seat coverincluding connection to drain ( or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. note : plastic seat cover shall be measured separately as supply only as considered under respective items. 85 supply only plasticwater closet seat cover, black, closed pattern with flat bottom and mild steelchromium plated or aluminium hinging device complete all as specified and directed. 86 s & f health faucets , abs body with 1.0 mtr longeasy flex tube inchrome finish and wall hook complete all as specified and directed. 87 s & f chromium plated toilet paper holder fixed to walls complete all as specified and directed. 88 m&l for point wiring for one light / fan / exhaust fan point / exhaust fan / bell / buzzer pointcontrolled by one way switch with using with frlsh pvc insulated pvc unsheathed electric cable conforming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 1.5 sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid pvc conduit isi marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 sqmm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal boxmade out of 1.6mm thick of suitable size, for mounting fittings / junction boxes including pvc board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing / fixing switches etc., complete all as specified and directed. note: proper colour coding to be adopted. 89 all as per item no. 88 here in before but 5 amp socket outlet on same board. 90 all as per item no. 88 here in before butfor 5 amp switch socketon independent board. 91 m&l for point wiring with frlsh pvc insulated pvc sheathed electric cable confirming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 2.50 sq.mm nominal cross sectional area for phase & neutral& including non metallic rigid pvc conduit isi marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 sq.mm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steelanodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with bakelite hylem sheet 2.80 mm thick complete for one switch socket outlet combination , 15 amps & 5 amp socket point on independent board controlled by one , one way switch complete all as specified and directed. 92 s & f switch piano flush button single pole one way 5 amp, complete all as specified and as directed. 93 s & f socket outlet 2 in 1, 3 pin, 5amp, flush type, universal, complete all as specified. 94 s & f switch socket combination 2 in 1, 3 pin, 5amp and 15 amp flush type, universal, complete all as specified. 95 s & f switch socket combination 2 in 1, 3 pin, 5 amp, flush type, universal, complete all as specified. 96 supply and fix ceiling rose three terminals pvc / polycarbonate, isolated body complete all as specified. 97 s & f lamp holder, pvc / polycarbonate type with back plate having matching colour to holder suitable for angle / batten fittings ( isi marked ) , complete all as specified. 98 s & f bell push type single pole one way 5 amps, complete all as specified. 99 s & f bell electric ding dong ac 230 volts single pole complete all as specified. 100 s & f ceiling rose three terminals pvc / polycarbonate, isolated body complete all as specified. 101 s&f five stepped type electronic fan regulator flush type controlled 230 v, , 120 watt etc complete all as specified and directed. 102 s&f for ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air dilivery 210 cfm with service value 6.00 bee. five star rated with brushless direct current motor ( bldc ) including connecting up with three core flexible copper conductor cable suitable sizefrom ceiling rose to fan terminal with necessary accessoriescomplete all as specified and directed. 103 s & f led light fitting 1 x 20watt , 220 v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by engr in charge.make: havells / bajaj / crompton greaves / phillips. 104 s & f led bulb of capacity 10 watt , lumen out put ( 950 ) lm , length 102 mm dia56 mm , base cap b22 ( isi mark ) complete all as specified and as directed by engr in charge.make: havells / bajaj / crompton greaves / phillips. 105 s & f plastic body exhaust fan of 250 mm sweep with louvers shutter, single phase , 230 v, 50 hz, 1200 rpmac , copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed. 106 s & f sheet metal enclosures for dbs when mcbs to used single pole and neutral ( spn ) double door 240 volts, 8 way with ip 43 ik 09 protection including 200 amp bus bar and neutral link ( isi marked ) , complete all as specified and as directed. 107 s & famp rating 240v, 10 ka c curve miniature circuit breaker ( mcb ) of single poles and neutral and current carrying capacity 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed. make: indoasian or its equivalent make in havells / standard / l&t. 108 s & f240v, 10 ka c curve miniature circuit breaker ( mcb ) of single polesand current carrying capacity 5 to 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed.make: indoasian or its equivalent make in havells / standard / l&t. 109 m & lsub main wiring two single core 6.0 sqmm pvc insulated frlsh multistanderd copper conductor cable and one run of 6.0 sqmmpvc insulated unsheathedfrlsh multi stranded copper conductor cablefor earth wire drawnin & including concealed rigid non metallic pvc conduit medium grade with fittings ( isi marked ) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. note : 2 runs of 6.0 sqmm cable and 1 run of earth wire 6.0 sqmm shall be measured as one unit length. 110 supply, laying , jointing & testing lt under ground cablexlpe insulated, screened , pvc bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty ) with standard aluminium conductor , 1100 voltsgrade of cross sectional area 16 sq mm 2.0 core complete all as specified and directed. 111 material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by engineer in charge.note: for measurement purpose punned thickness shall beconsidered as per clause 19.75 of ssr part i. 112 supplying & laying un reinforced pre cast flat concrete cable protection cover of class lv, type 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the engineer in charge. 113 s & f 25 mm bore gi tube, light grade for cable protection with all necessary fitting, complete with all fittings laid as in floor etc., complete all as specified and as directed. 114 m&l , for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by gi pipe 15 mm bore ( light grade ) and watering pipe 20 mm bore gi pipe ( light grade ) and pcc of chamber and coping shall in 1:3:6 type c 1 using 20 mm graded stone aggregateincluding excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate no 3 of ssr pt i, 2009 with ci cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. note : earth test report should be submitted by the contractor duly tested in presence of engineer in charge 115 m&l for boring ofhole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine with & including provision of 50 mm borelight grade gi pipefor protection of cable complete all as specified and directed by engineer in charge.note : pipes shall be laid minimum 2.00 mtr below / under existing road surfaces / taxi track / apron / floors etc. 116 cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1 / 2 round or ¾ section ) in cement concrete 1:2:4 type b 1 smooth finished, and reforming benching as required in 150mm internal diapipe complete all as specified and as directed....
35457675 rectification work for replacement of non green earth wire in c 3 and db building at ktps dvc township proposal for rectification work for replacement of non green earth wire with green earth wire as per is and nec specification in c 3 and director bungalow building pertaining to colony township area at dvc ktps => limited...
35351945 proposal for rectification work for replacement of non green earth wire with green earth wire as per is & nec specification in c#3 and director bungalow building pertaining to colony township area at dvc, ktps....
35146193 tender for supply of following materials earthing g.i. strip for (65x6) t/c fuse wire 12 swg t/c fuse wire 14 swg t/c fuse wire 16 swg t/c fuse wire 18 swg gi wire 6 swg gi wire 8 swg gi wire no. 10 for earthing earthing (chemical) with gi earthing pipe 20 mm 2.5 mtrs. long gi earthing pipe 3.1 meter long (40 mm dia) earth clamp for earth wire (50 x 6 mm) [galvanized] stay set complete (1900x20 mm) with stay wire 7/10 swg 8 kg & guy insulator) stay set complete (1800x20 mm) with stay wire 7/10 swg 8 kg & guy insulator) stay set complete for dss with wire lt stay set complete (1700x16 mm) with stay wire 7/12 swg ...
35143346 erection of cradle guard, earth wire and installation of chemical earthpits below ht oh line under urimari ocp. erection of cradle guard, earth wire below ht oh line and construction of maintenance free chemical earth pit in ht oh line of different 11kv and 3.3kv overhead line under urimari ocp....
35053295 erection of poles, drawing of conductor and earth wire of 3.3 kv line quarry feeder for day to day work of gidi c colliery...
35042315 tender for erection of poles, drawing of conductor and earth wire of 3.3 kv line quarry feeder for day to day work of gidi c colliery...
35001872 erection of pole, drawing of conductor and earth wire of 3.3 kv o/h line in quarry feeder of religara colliery under argada area....
35001334 erection of pole, drawing of conductor and earth wire of 3.3 kv o/h line in quarry feeder of religara colliery under argada area....
34972110 provision of medical store office at mh ramgarh 1 surface excavation notexceeding 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed. 2 add to (or deduct from) above itemno. 1 for every 3cm or part there of above or below 15 cm average depth complete all as specified and directed. 3 excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient forlaying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. 4 returning, filling in including spreading, leveling, watering and well ramming in layers ofnot exceeding 25 cm thickafter the cables & pipes etc. are laid, jointed & testedand foundations complete all as specified and directed by engineer in charge. 5 removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by engineer in charge at a level not exceeding 1.5 m above the starting point complete all as specified. 6 m&l for plain cement concrete 1:4:8 type d 2(using 40 mm gradedcrushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed. 7 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in foundation including rafts, footings,plinth beams, and mass concreteetc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 8 m& lfor use & wasteof form work to sides of concrete foundation, base of coloumn ,rafts,footings, plinth beams, andplinth beamand similar work for rough finished flat surfaces of concrete complete all as specified and directed. 9 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as incolumns,pillars,piers,popst and struts etc.complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 10 m& lfor use and waste of form work to sidesof columns,pillars,piers,post and struts for rough finished surface of concrete complete all as specified and directed. 11 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the likecomplete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 12 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in lintels beam, floor/roof beams, cantilevers, bressummers, ,etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 13 m&l reinforced cement concrete m 25 (design mix)(using20 mm gradedcrushedstoneaggregate)as in chajja etc complete all as specified and directed.note : reinforcement & form work will be measured & paid seperately under respective item of boq. 14 m& lfor use and waste of form work to sidesof soffit ofchajja,chullah hoods,troughs & similaritemsetc includingfor rough finished surface of concrete complete all as specified and directed. 15 m& lfor use and waste of form work to sidesofsoffit ofsuspended slab such as roof slab ,floor slab ,landing and similar work , not exceeding 200 mm thick for rough finished surface of concrete complete all as specified and directed. 16 m& lfor use and waste of form work to sidesandsoffit oflintel beam,floor/roof beams, etcfor rough finished surface of concrete complete all as specified and directed. 17 use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor & roofs and sides of rcc/ pcc bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide rough finished surface of concrete complete all as specified and directed. 18 m&l for brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 etc complete all as specified & directed. 19 m&l for halfbrick thick brick work using fly ash bricks old size , straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:4 etc complete all as specified & directed. 20 m&l for with moorum/ red bajri fillingunder the floor not exceeding 100 mm thick spreaded, levelled and rammed including watering complete allas specified & directed . 21 m&l forpre constructionantitermite treatment for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 22 m&l forpre constructionantitermite treatment for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of verticalsurface (area of the sub structure in contact with backfill to be measured) complete allas specified & directed . 23 m&l forpre constructionantitermite treatment for treating the the top surface of filledat the rate of5 litres of emulsion per square metre of surfacecomplete allas specified & directed . 24 m&l forpre constructionantitermite treatment for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete allas specified & directed . 25 s & f brass4 screw plate drawer pulls, plate with fixed dished pull; 80 mm to 100mmlong complete all as spcefied and directed 26 s & f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with ms square tubes suppyling & fixing in opening as per specification & drawing complete all as spcefied and directed by engr in charge . 27 s & f for factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tube for top and bottom rails. ms framed shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour pvc sheet for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail, paneling of plain colour pvc sheet to be fitted in the ms framed welded/sealed to stiles & rails with suitable pvc sheet beading & joined together with solvent cement complete all asfixing in the frame at site as per specification and drawing including 3 nos stainless steel butt hinges 100 mm long for each door, complete all as specified and as directed. 28 s&f 100 mm long aluminium anodised barrel tower bolts of extruded section and fixed all as specified and directed. 29 s & f 100mm sizebutt hinges medium weight cold rolled mild steel complete all as specified and directed . 30 s&f 150mm extruded aluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 31 s&f 150mmaluminium alloy handles, cast type, anodisedcomplete all as specified& directed. 32 s&f of aluminium mortice lock,vertical type, size 75 mm four levers (isi marked) for aluminium doorscomplete all as specified and directed. 33 s&f 65 mm ,four lever brasslocks, drawer,grade i of size 65 mmcomplete all as specified and directed. 34 s&ffloor door stopper of aluminium alloy body& tounge,150 mm ,anodised with hard drawn steel spring fixed in floor complete all as specified and directed. 35 s&f brass4 screw drawer plate with fixed dished pull; 80 mm to 100mm longcomplete all as specified and directed. 36 s&ffloor double action spring hinges,brass with phosphor bronze wire spring, bright polished of size 100 mm complete all as specified and directed. 37 m & l for 18/19 mm thick prelaminated particle board exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timberframe work complete all as specified and directed. 38 s&f 40mm dia,brass ,cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed. 39 s&fbrass handles 150mm size cast type ,polished brightcomplete all as specified and directed. 40 m&l for mild steel tmt bars 10mm dia and over grade fe 500, cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 41 m&l for mild steeltmt bars 08 mm dia and over grade fe 500 , asin stirrups, spacers & binders ,cut to length, bent to shape required, including cranking bending spirally for hooping for column,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete etc all as specified and directed. 42 m&l for hard core of broken stone or bouldergauge not exceeding 63mm deposited, spread & leveled in layers not exceeding15cm thick, watered and rammed to a true surface etccomplete all as specified& directed. 43 m & l for 75 mm thick plain cement concrete (1:3:6) mix, type c 1 (using 20mm graded crushedstone aggregate ) as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide, 75mm deep joints made at 3.00 m in length and filled with bitumen 85/25 gradeand sand in the ratio 1:3 including necessary form work , complete all as specified and directed. 44 m & l joint free non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc., over and including 15mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces,complete all as specified and directed. 45 m & l glazed ceramic coloured tiles of size 375 mm x 250 mm x7mm/450 mmx 300 mm x7 mm thick,as in dado/skirting etc ,set and jointed in neat cement slurry and pointed in colour cement to match the tiles including 10 mm thickrendering in cement plaster in cm (1:3), complete all as specified and directed. 46 m&l for vetrifieddark shed coloured ceramicfloor tiles10 mm thick (square/rectangular) area of each tileexceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in cloured cement to match the shade of tiles over & including 15 mm thick screed bed in cement mortar (1:6) etc complete all as specified &directed. 47 m&l for vetrifieddark shed ceramic tiles 10 mm thick (square/rectangular) area of each tilenot exceeding 0.36 sqmon vertical surface such as skirting / dado etc ,set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over & including 10 mm thick backing coat in cement mortar (1:4) etc complete all as specified & directed. 48 m&l for rendering 10 mm thick on brick masonry/concrete surface etc in cm (1:6) surface finished even & smooth using extra cement complete all as specified and directed. 49 m&l for rendering 15 mm thick on other than fair face brick masonry/concrete surface etc in cm (1:4) surface finished even & smooth using extra cement complete all as specified and directed. 50 m & l for rendering 5 mm thick in cm 1:4 on concrete surfaces as in ceilingfinished even and faircomplete all as specified and directed. 51 m&l for preparation of newly plastered surfaceof wall and applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specifiedand directed. 52 m&l for preparation of newly plastered surface of ceilingand applying two coats of oil emulsion distemper over a coat of primer and a layer of putty (not less than 1.5 mm thick )complete all as specifiedand directed. 53 m&l for preparation of newly plastered surfaceof externalwall andapplying two coatacrylicexterior emulsion paint of required shade over and including priming coat of exterior primer and a layer of putty (not less than 1.5 mm thick ) complete all as specifiedand directed. 54 s &f powder coated aluminium work for doors, windows, ventilators shutters(fixed/sliding track two or three track) and partitions frames with extruded built up standard sections of approved make fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with sealent with wall, i.e. at top, bottom and sides including cleat angle,c.p. brass/ stainless steel screws, all complete all as specified and directed. 55 s&f powder coated aluminiumsliding door shutters (minimum thickness of powder coating 50 micron) , aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings such as peg stays 150mm long (1no.),100mm long hinges type b 21 (2nos), suitable handle(02 nos.) in each door top rail guide rail etc. complete all as specified and directed. 56 &f powder coated aluminiumwindow and ventilatorshutters (minimum thickness of powder coating 50 micron) ,fixed typewithout sash baraluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing anodised aluminium, snap beading screws, powder coated aluminium fittings complete all as specified and directed. 57 s&ffor anodised aluminium grillsfor windows and ventilatoraluminium sections (weightnot less than 2.25 kg/sqm) size4mmx4mm, 8mm thick and aperture not exeeding 80 mmx 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tintcomplete all as specified and as directed. 58 s&f 5.5 mm thick sheet glass not exceeding 0.5 sqm ineach pane of superior quality fixed to aluminium frame work with rubber neoprene beadingincluding solar control film 50 micron reflective type sticked to glasspanes as per instructions of manufacturers completeall as specified & directed. 59 s&f 4 mm thick figured glass pin headed type in squares/ rectangularnot exceeding 0.5 sqm ineach pane glazing with oil putty or aluminium frame/shutters with rubber neoprene beadingcomplete etc all as specified & directed. 60 s&f for gi water tubing mediumgrade, isi marked,galvanised, 15 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls and ceiling or laid in floors including cutting chasees for brick wallsand making good the surface in cement mortar 1:3 complete all as specified & directed. 61 s&f for gi water tubing mediumgrade, isi marked,galvanised, 25 mm bore with all fittings, (such as tee, elbow, socket, union & short pieces) fixed to walls /laid in trenches and ceiling or laid in floors including cutting chasees for brick wallsand making good the surfacein cement mortar 1:3 complete all as specified & directed. 62 s&f rotational moulded polythene water storage tank of capacity 1000 ltrs (cylindrical/vertical with closed type), triple layer construction, isi marked, hoisted and fixed in position including 20 mm bore gi nipple and20 mm bore ball/ float valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 210 gms)complete all as specified and directed. 63 s&f 20 mm borebrass ball/ float valves high pressure with polythene float & fly nutcomplete all as specified and directed. 64 s&f bib taps long body, cast copper alloy with capstan head or butter fly handle, chromium platedfancy type with long body shank, screwed down with high pressure screwed for iron pipe and fixed 15 mm bore complete all as specified &directed. 65 s&f fancy type angle stop valve fancy type chromium plated with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15 mm bore complete all as specified &directed. 66 s&f pillar taps fancy type, cast copper alloy with capstan head, chromium plated, screwed down with or without lettered hot or cold with long screw shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore complete all as specified & directed. 67 s&f for pvc connection 15 mm dia size with ptmt nuts of length 450 mmcomplete all as specified and directed. 68 s&f 75 mm bore pvc(swr) pipes single socketed , in any length with rubber ring joints, laid in trenches ,floor or inwall complete all as specified and directed. 69 m&l for 75mm pvc (swr) floor trap, plain with grating including jointing with solvent cementwithchromium platedgratingwith or without hole complete all as specified and directed. 70 s & f600mm x 450 mm bevelled edge looking mirror of selected quality glass mounted on 6 mm thick pvc sheet with pvc frame and fixed to wooden plugs with cp brass screw and cup washers complete all as specified and directed. 71 s & f pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float and handle, pvc flush pipe 32 mm bore & pvc connection 15 mm bore 450 mm long with ptmt nuts and brackets complete set all as specified anddirected. 72 s & f vitreous china wash basin, any colour, flat back size 550 mm x 400mm including 32mm brass chromium platedwaste coupling ,pvc 32 mm bore waste pipe, chromium plated gratingincluding bracket complete all as specified and directed. 73 m&l for pcc 1:2:4 type b 1 (using 20mm graded crushed stone aggregates) in kerbs or mud stops, rounded or chamfered on edges water troughs and the like including necessary form workcomplete all as specified and directed. 74 m & l for 15 mm thick screed bed in cement mortar 1:4 mixedwith usingliquid water proofing compoundas per manufacturers instructionsover roof top surface finished even and smooth using extra cement and application of water proofing treatment using app modified roof membrane over existing non accessible/non approachablercc roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed : (a) cleaning existing surface properly.(b) applying approved bituminousbased primer @ 0.30 litre / sqm manufactured by the same agency as that of app membrane with a density 0.87 0.89 kg per liter at 25 degree centigrade on prepared surface &hot blown grade bitumin85/25 @ 1.2 kg/sqm over primer .(c) laying not less than 3mm thick app modified water proofing membrane weighing not less than 3.00 kg/sqm reinforced with non woven polyster fiber weight not less than 160gsm/sqm using butane torch by torch application with 10cm side laps and 15cm end lap. physical property of membrane shall be as under : (i) membrane weight not less than 3.00 kg/sqm. (ii)non woven polyester weight not less than 160 gsm/sqm.(iii)softening point of membrane not less than 150degree celsius. (iv)joint tensile strength longitudinal not less than 650 kg / sqcm and transverse not less than 450 kg /sq.cm at230 degree celsius. (v) tear strength longitudinal not less than 300 n& transverse not less than 250n.(vi)elongation of reinforcement not less than 30%.(vii) impermeability under water pressure not less than 3 kg/sqcm.(d) app membrane shall be laid using butane torch by torch application with minimum 10cm side overlap and 15cm end lap. (e) applying two coat of bituminiousbased aluminium paint @ 0.3 kg /sqm over app membrane.(note:water proofing compound shall be measured and paid seprerately under respective item of boq) 75 supply only liquid water proofing compound complete all as specified and directed. 76 m&l for 60mm thick factory mademachine pressed pre cast concrete coloured interlocking paver blockof approved shade of any shape and size conforming to is 15658 2006 of m 35 grade laid over &including cleaned dry sand cushion bed 50mm thick over &including 100 mm thick pcc 1:4:8 type d 2 (using 40mm graded crushed stone aggregate) assub base, surface finished even and rough over and including 75mm thick hardcore of broken boulder of gauge n exc. 63mm, deposited, spread and levelled, watered and rammed to a true surface, etc complete all as specified and directed. 77 m & l for 100 mm thick concrete bed to 150 mm bore drain pipe including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type d 2 (using 40 mm gradedcrushed stone aggregate ) complete all as specified & directed. 78 m & l for 150 mm bore (internal dia )reinforced concrete drain pipe ,class np 3, laid and jointedin trenches complete all as specified & directed. 79 m&l for plain cement concrete 1:3:6 type c 2(using 40 mm gradedcrushed stone aggregate) as in foundations, bed of manhole ,filling & mass concrete etc complete all as specified and directed. 80 m&l for plain cement concrete 1:2:4, type b 1 (using 20 mm graded crushed stone aggregates) as in surface channels /benching of manhole ,drain ,laid to shape and slopeand surface finished even & smooth using extra cement complete all as specified and directed 81 s& f 25 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 82 m&l for drilling in existing water pipe, taking new tapping from existing pipe,proper welding to the pipe surface complete all as specified and directed 83 s& f towel ring of ptmt fixed with and including chromium plated brassscrews and wooden/plasticcleats (minimum weight 90 gms) complete all as specified and directed 84 s&f vitreous china wash down water closet (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), fixing seat coverincluding connection to drain (or outgoing pipe, and to flushing pipe & antisyphonage pipe etc with aluminium hinging device complete all as specified and directed. note : plastic seat cover shall be measured separately as supply only as considered under respective items. 85 supply only plasticwater closet seat cover,black,closed pattern with flat bottom and mild steelchromium plated or aluminium hinging device complete all as specified and directed. 86 s & f health faucets ,abs body with 1.0 mtr longeasy flex tube inchrome finish and wall hook complete all as specified and directed. 87 s & f chromium plated toilet paper holder fixed to walls complete all as specified and directed. 88 m&l for point wiring for one light/fan/exhaust fan point /exhaust fan/ bell /buzzer pointcontrolled by one way switch with using with frlsh pvc insulated pvc unsheathed electric cable conforming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 1.5 sq.mm nominal cross sectional area for phase & neutralandincluding non metallic rigid pvc conduit isi marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system & 1.5 sqmm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including sunken type anodized pressed steelsheet terminal boxmade out of 1.6mm thick of suitable size, for mounting fittings/junction boxes including wooden board with bakelite sheet 2.8 mm thick laminatedcover make sheet for housing/fixing switches etc., complete all as specified and directed. note: proper colour coding to be adopted. 89 all as per item no. 88 here in before but 5 amp socket outlet on same board. 90 all as per item no. 88 here in before butfor 5 amp switch socketon independent board. 91 m&l for point wiring with frlsh pvc insulated pvc sheathed electric cable confirming to is:694, 1100v grade ac, single core having multi stranded copper conductor of size 2.50 sq.mm nominal cross sectional area for phase & neutral& including non metallic rigid pvc conduit isi marked medium grade not less than 25 mm dia with all conduit accessories in concealed wiring system & 2.50 sq.mm green pvc insulated unsheathed multistranded copper conductor as a earth wire connected to earth dolly by providing lugs including pressed steelanodized sunken boxes 60 mm deep & 1.6 mm thick duly painted inside & anticorrosive outside with bakelite hylem sheet 2.80 mm thick complete for one six pin switch socket outlet combination ,15 amps & 5 amp socket point on independent board controlled by one ,one way switch complete all as specified and directed. 92 s & f switch piano flush button single pole one way 5 amp, complete all as specified and as directed. 93 s & f socket outlet 2 in 1, 3 pin, 5amp, flush type, universal, complete all as specified. 94 s & f switch socket combination 2 in 1, 3 pin, 5amp and 15 amp flush type, universal, complete all as specified. 95 s & f switch socket combination 2 in 1, 3 pin, 5 amp, flush type, universal, complete all as specified. 96 supply and fix ceiling rose three terminals pvc/ polycarbonate, isolated body complete all as specified. 97 s & f lamp holder, pvc/polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (isi marked), complete all as specified. 98 s & f bell push type single pole one way 5 amps, complete all as specified. 99 s & f bell electric ding dong ac 230 volts single pole complete all as specified. 100 s & f ceiling rose three terminals pvc/ polycarbonate, isolated body complete all as specified. 101 s&f five stepped type electronic fan regulator flush type controlled 230 v, , 120 watt etc complete all as specified and directed. 102 s&f for ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air dilivery 210 cfm with service value 6.00 bee. five star rated with brushless direct current motor (bldc) including connecting up with three core flexible copper conductor cable suitable sizefrom ceiling rose to fan terminal with necessary accessoriescomplete all as specified and directed. 103 s & f led light fitting 1 x 20watt , 220 v, ac decorative box type with driver, holder including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by engr in charge.make: havells/bajaj/crompton greaves/phillips. 104 s & f led bulb of capacity 10 watt , lumen out put (950)lm ,length 102 mm dia56 mm , base cap b22 (isi mark) complete all as specified and as directed by engr in charge.make: havells/bajaj/crompton greaves/phillips. 105 s & f plastic body exhaust fan of 250 mm sweep with louvers shutter,single phase ,230 v,50 hz,1200 rpmac ,copper winding , including provision of hole, mounting frame, nut, bolts, washer, fasteners etc and connecting exhaust fan to ceiling rose including provision of three core flexible copper cable of size 1.5 sqmm not less than 0.5 mtr long for connection complete all as specified & directed. 106 s & f sheet metal enclosures for dbs when mcbs to used single pole and neutral (spn) double door 240 volts, 8 way with ip 43 ik 09 protection including 200 amp bus bar and neutral link (isi marked), complete all as specified and as directed. 107 s & famp rating 240v, 10 ka c curve miniature circuit breaker (mcb) of single poles and neutral and current carrying capacity 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed. make: indoasian or its equivalent make in havells/standard/l&t. 108 s & f240v, 10 ka c curve miniature circuit breaker (mcb) of single polesand current carrying capacity 5 to 32 amp in the mcb db complete with connection testing and commissioning all as specified and as directed.make: indoasian or its equivalent make in havells/standard/l&t. 109 m & lsub main wiring two single core 6.0 sqmm pvc insulated frlsh multistanderd copper conductor cable and one run of 6.0 sqmmpvc insulated unsheathedfrlsh multi stranded copper conductor cablefor earth wire drawnin & including concealed rigid non metallic pvc conduit medium grade with fittings (isi marked) not less than 25 mm dia, complete and making good disturbed surface wall complete all as specified and as directed. note : 2 runs of 6.0 sqmm cable and 1 run of earth wire 6.0 sqmm shall be measured as one unit length. 110 supply, laying , jointing & testing lt under ground cablexlpe insulated, screened ,pvc bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 voltsgrade of cross sectional area 16 sq mm 2.0 core complete all as specified and directed. 111 material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by engineer in charge.note: for measurement purpose punned thickness shall beconsidered as per clause 19.75 of ssr part i. 112 supplying & laying un reinforced pre cast flat concrete cable protection cover of class lv, type 2, size 250 mm x 150mm x 40mm, factory made, complete all as specified and directed by the engineer in charge. 113 s & f 25 mm bore gi tube, light grade for cable protection with all necessary fitting, complete with all fittings laid as in floor etc., complete all as specified and as directed. 114 m&l ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by gi pipe 15 mm bore (light grade) and watering pipe 20 mm bore gi pipe (light grade) and pcc of chamber and coping shall in 1:3:6 type c 1 using 20 mm graded stone aggregateincluding excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate no 3 of ssr pt i, 2009 with ci cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. note : earth test result should not less than one ohm. 115 m&l for boring ofhole under road, pavement, hard standing without disturbing existing surface by trenchless technology using ultra sound technique and necessary machine with & including provision of 50 mm borelight grade gi pipefor protection of cable complete all as specified and directed by engineer in charge.note : pipes shall be laid minimum 2.00 mtr below/under existing road surfaces/taxi track / apron /floors etc. 116 cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type b 1 smooth finished, and reforming benching as required in 150mm internal diapipe complete all as specified and as directed. ...
34889006 tender for erection of 220v, overhead lighting line at 2 seam of kocp departmental patch, under bastacolla area 1 errection of 10 mtr. pole 2 transporting of pole 3 supply and errection of stay set 4 supply and errection of nut bolts & clamps 5 supply and errection of shackle insulator 6 errection of conductor 7 supply of swg 8 no. g.i. wire 3.3 kv o / h line and 220v o / h line 8 errection of earth wire 9 errection of guard wire 10 errection of two wire bracket 11 total impact of gst for the purpose of ctc...
34865200 tender for breakdown maintenance of eii / c replacement of faulty and old tube light fittings , repairing of fans , rewiring and out door light at main te building , ranchi under ranchi ba replacement of following faulty electrical items by new one i / c testing etc complete as reqd. 2 a ) 20 watt led tube light batten type fitting 3 b ) 20 watt led tube light retrofit type 4 c ) retrofit type 20watt tube light fitting 5 d ) led bulb 9 watt 6 e ) 15 a socket 7 f ) 15 / 16 amp switch 8 g ) 5 amp switch 9 h ) 5 amp socket 10 i ) fan regulator 11 through checking of faulty tube lights , street light and wiring etc i / c detection of fault, disconnection of wiring , cleaning and fittings etc as per site required. 12 s / f of 50 watt street light led type fittingmade up of diacast housing with toughned glass and individual leds with secondary optics and ip66 / 65 protectionsuitable for 230 volts 50 hz connectioni / c gi pipe 40mm dia etc as reqd. ( m / shavels or ss make ) 13 s / f of 100watt flood light led type fittingmade up of diacast housing with toughned glass and individual leds with secondary optics and ip66 / 65 protectionsuitable for 230 volts 50 hz connectioni / c gi pipe 40mm dia etc as reqd. ( havels or ss make ) 14 supply and installation of ceiling fan of 1200mm sweep , 50 watt, min 370 rpm, min. air delivery 215cmmsuitable for 230v , 50hz power supply as per site reqd. ( cropmton entrust 50 or ss make ) 15 repairing / rewinding / servicing of faulty ceiling / wallmounted / exhust fans i / c testing, commissioning etc as reqd. 16 a ) 1200 / 1400 mm ceiling / wall mounted fan 17 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 18 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 19 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 20 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 21 2 x 1.5 sq. mm 22 3 x 1.5 sq. mm 23 3 x 4 sq. mm 24 6 x 4 sq. mm 25 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 26 single pole 27 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. 28 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 29 4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire 30 replacement of control panel for 5 hp submersible pump making 16 guage ms sheet i / c starter, voltmeter, ammeter, selector switch and short cicuit protection etc as reqd. ( make: bch cat cpeynajn or similar superior make ) 31 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 32 8 way , double door 33 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 34 40 a 35 63 a 36 supplying and fixing brass batten / angle holder including connection etc. as required....
34737460 procurement of electrical materials under adp om head for fy 2022 23 under electric supply area jamshedpur , electrical items : , gi earthing pipe 3.1 meter long & 40 mm dia including 10 kgs bentonite clay or powder. , earthing g.i.strip for ( 65x6 ) , gi wire no. 10 for earthing , earth clamp for earth wire ( 50 x 6 mm ) [ galvanized ] ...
34665030 e tender notice for supply of electric line materials under adp & o & m head for financial year 2022 23. 1 gi earthing pipe 3.1 meter long & 40 mm dia including 10 kgs bentonite clay or powder. 2 earthing g.i. strip for (65x6) 3 gi wire no. 10 for earthing 4 earth clamp for earth wire (50 x 6 mm) [galvanized] ...
34590139 supply of materials and installation of power supply arrangement through fresh electrical wiring 1 wiring for circuit /submain wiring along with earth wire with the following size of fr pvc insulated copper conductor ,single core cable in surface/recessed medium class pvc conduit as required. 2 2x10 sq. mm+1x6 sq. mm earth wire 3 2x16 sq. mm+1x6 sq. mm earth wire 4 2x6 sq. mm+1x6 sq. mm earth wire 5 2x2.5 sq. mm+1x2.5 sq. mm earth wire 6 supplying and fixingdp sheet steel enclosure on surface/recess along with 25/32 amps 240 volts c curve dp mcb complete with connections,testing and commossioning etc.as required. 7 supplying and fixing following way,single pole and neutral,sheet steel,mcb distribution board,240 volts,on surface/recessed,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar, interconnections, powder painted including earthing etc.as required.(but without mcb/rccb/isoltor) 8 2+4 way,single door 9 2+6 way,single door 10 2+10 way,single door 11 supplying and fixing 5 amps to 32 amps rating,240/415 volts,c, miniature circuit breaker suitable for inductive load of following poles of existing mcb db complete with connections,testing and commining etc.as required. 12 double pole,32 amp 13 double pole,25 amp 14 single pole,20 amp 15 single pole,16 amp 16 single pole,10 amp 17 wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface/recessed medium class pvc conduit ,with piano type switch,phenolic laminated sheet ,suitable size m.s. box and earthing the point with 1.5 sq. mm fr pvc insulated copper conductor single core cable etc as required. 18 group b 19 supply and fixing following piano type switch/soccket on the existing switch box/cover including connections etc as required. 20 5/6 amps switch 21 3 pin 5/6 amp socket outlet 22 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/wooden block including connection etc as required. 23 supplying and fixing call bell/buzzer suitable forsingle phase, 230 volts, complete as required.required. 24 20 mm junction box,one way/two way 25 supplying and fixing brass batten/ angle holder including connection etc.as required. 26 supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. 27 wiring for light/power plug with 2x4 sq. mm fr pvc insulated copper conductor single core cable in surface/recessed medium class pvc conduit along with 1 no 4 sq.mm fr pvc insulated copper conductor single core cable for loop earthing as required. 28 supply and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection,painting etc. as required. 29 supply and fixing metal box of 150 mm x 75 mm x 60 mm deep(nominal size of phenilic laminated sheet cover in front including providing and fixing 3 pin 5 / 6amps socketoutlet and 5 / 6 amps piano type switch, connection, painting etc. as required. 30 supply and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 31 100mmx100mmx60mm deep 32 eartthing with g.i. earth plate 600 mm x600 mm x 6 mm thick including accessories and providing masonry encloused with cover plate havinglocking arrengement and watering pipe of 2.7 metre long etc.with charcoal/coke and salt as required. 33 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required. 34 providing and fixing 63a,16ka,three pole mccb in existing cubical pannel including drilling holes in cubical panel,making connections, etc as requrired. 35 enclosure for 63a mccb of sheet steel,dust protected,dully powder painted. 36 supply & fixing inclosure for 40 amp and 25 ampdp, mcb as an out going distribution boardof sheet steel, dust protected,dully powder painted. 37 providing and fixing 40a,16ka,dp mcb in existing cubical panel including ,making connections, etc as required 38 light shed 39 providing and laying earth connetion from earth electrode with6 swg dia g.i. wire in 25 mm dia pvc pipe of medium class from eatrth electrode including connection with g.i thimble, refilling as required. 40 miscellaneous including cleaning of rubbish, mending of wall, floor damage etc. 41 total impact of gst for the purpose of ctc ...
34320894 repair and maintenance of 33 / 3.3kv o / h line from reg. sub station to cpp plant, earth wire restringing with earthing connection, earth pit and pole painting etc....
34261248 auction sale of lot no: 23.0 lot name: old & used dismantled earth wire...
34168452 tender for electrical works in hoc, cwc, maithon rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wire in existing surface / recessed steel / pvc conduit including dismantling as required. 2 supplying, assembling and fitting of pvc electric board box ( 75 mm x 75 mm x 50 mm pvc box ) excluding switch and sockets. 3 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required. 4 5 / 6 amps switch 5 15 / 16 a switch 6 3 pin 5 / 6 a socket outlet 7 6 pin 15 / 16 a socket outlet 8 supplying and fixing of 20 mm of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 9 earthing with copper earth plate 600 mm x 600 mm x 3 mmthick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 meter long etc. with charcoal / coke and salt as required 10 supplying and fixing dp sheet steel enclosure on surface / recess along with 25 / 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required....
33997673 supply of different type of fabrication materials , electrical items : , clamp ( 50x6 ) mm for top channel forrail pole 2.40 kg ( galvanized ) , clamp ( 50x6 ) mm for abswitch base channel 1.75 kg ( galvanized ) , ms channel ( 100x50x6 ) mm for 11 kv ab switch 53.44 kg ( galvanized ) , 33 kv pole top bracket 2.90 kg ( galvanized ) , 33 kv backclamp for8mtr pole ( 50x6 ) mm 1.00 kgtop bracket ( galvanized ) , 33 kv vcrossarm ( 100x50x6 ) mm20.48 kg ( galvanized ) , m / s base plate for 33 kv ( 18.00 kg ) , back clamp ( 50x6 ) mm for 60 kg rail pole 1.95 kg ( galvanized ) , support clamp for vcross arm for 60 kg rail pole ( 1.79 ) kg ( galvanized ) , back clamp ( 50x6 ) mm jointing / packingpiece for 60 kg rail pole 0.80kg ( galvanized ) , 33 kv angle stay clamp 1.75 kg ( 50x6 ) mm ( galvanized ) , 33 kv clamp for line dp channel ( 4.20 kg ) ( galvanized ) , 33 kv d.p channel support clamp ( 50x6 ) mm 2.16 kg ( galvanized ) , 33 kv d.p channel ( 100x50x6 ) mm 52.00 kg ( galvanized ) , earth clamp for earth wire ( 50x6 ) mm 1.60kg ( galvanized ) , 11 kv pole top bracket 50x8 mm 2.10kg ( galvanized ) , 11 kv back clamp for top bracket 1.0 kg ( galvanized ) , 11 kv v cross arm ( 75x40x6 ) mm 10.93 kg ( galvanized ) , support clamp for 11 kv v cross arm 1.0 kg ( galvanized ) , 11 kv back clamp for line dp channel ( 40x6 ) mm 2.60 kg ( galvanized ) , 11 kv d.p channel support clamp ( 50x6 ) mm ( 1.80 kg ) ( galvanized ) , 11 kv d.p channel ( 75x40x6 ) mm 32.32 kg ( galvanized ) , anglestay clamp ( 50x6 ) mm for 8 mtr long 200 kg psc pole 1.65 kg ( galvanized ) , side stay clamp ( 50x6 ) mm for 8 mtr long 200 kg psc pole 1.65 kg ( galvanized ) , 11 kv angle stay clamp ( 50x10 ) mm 1.95 kg ( galvanized ) , 11 kv top channel ( 100x50x6 ) mm 53.44 kg ( galvanized ) , ms angle for lt distribution bus ( 35x35x6 ) mm 18.00 kg ( galvanized ) , clamp ( 50x6 ) mm for transformer base channel2.16 kg ( galvanized ) , clamp ( 50x6 ) mm for transformer belting 2.16 kg ( galvanized ) , clamp ( 50x6 ) mm for ltbusset0.90 kg ( galvanized ) , clamp ( 50x6 ) mm forhg fuseset 0.90 kg ( galvanized ) , m / s flat ( 75x40x6 ) mm ( galvanized ) ...
33975299 bids are invited for construction of community centre atturamdih township 1 earth work in excavation by mechanical means hydraulic excavator or manual means over areas exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan including disposal of excavated earth lead upto 50m and lift upto 1.5m disposed earth to be levelled and neatly dressed complete as per direction of eic. 2 excavating trenches of required width for pipes cables etc including excavation for sockets depth upto 1.5 m including getting out the excavated materials returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed within a lead of 50m as per direction of eic. pipes cables etc. not exceeding 80 mm dia. 3 filling available excavated earth excluding rock in trenches plinth sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 4 supplying and filling in plinth with foundation plinth wall sand under floors including watering ramming consolidating and dressing complete as per direction of eic. 5 surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 m and lift upto 1.5 m all kind of soil. 6 diluting and injecting chemical emulsion for postconstructional antitermite treatment excluding the cost of chemical emulsion treatment of soil under existing floors using chemical emulsion the existing floor. 7 treatment of existing masonry using chemical emulsion at the rate one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1 isto 2 1 cement isto 2 coarse sand to the full depth of the hole with chlorpyriphos or lindane ec 20 per cent with 1 percent concentration 8 providing and laying damp proof course 40mm thick with cement concrete 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 12.5 mm nominal size. 9 extra for providing and mixing water proofing material in cement concrete work at the rate 1 kg per 50kg of cement. 10 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size including cost of cement reinforced cement as per direction of eic. 11 rcc in retaining walls roofs return walls walls any thickness including attached pilasters columns piers abutments pillars posts struts buttresses string or lacing courses parapets coping bed blocks anchor blocks plain window sills fillets upto floor five level excluding the cost of centering shuttering and finishing 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size. 12 centering and shuttering including strutting propping etc. and removal of form for lintels beams plinth beams girders bressumers and cantilevers as per direction of eic. 13 reinforcement for rcc work including straightening cutting bending placing in position and binding all complete cold twisted bars 14 brick work with fps bricks of class designation 75 in foundation and plinth in cement mortar 1 isto 6 1 cement isto 6 coarse sand including mixing of mortar laying of bricks raking joints curing etc complete including cost of cement specification and direction of eic. 15 brick work with fps bricks of class designation 75 in super structure in cement mortar 1 isto 6 1 cement isto 6 coarse sand including mixing of mortar laying of bricks raking joints curing etc complete including cost of cement specification and direction of eic. 16 half brick masonry with fps bricks of class designation 75 in superstructure above plinth level upto floor v level. cement mirtar 1 isto 4 1 cement isto 4 coarse sand complete as per the direction of eic. 17 providing and fixing isi marked flush door shutters conforming to is2202 part i decorative type core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 30mm thick including isi marked stainless steel butt hinges with necessary screws complete as per the direction of eic. 18 providing and fixing oxidised ms sliding door bolts with nuts and screws etc. complete 300 into 16mm 19 providing and fixing oxidised ms tower bolts black finish barrel type with necessary screws etc. complete 20 providing and fixing oxidised ms handles with necessary screws etc. complete 125mm 21 providing and fixing factory made steel glazed doors windows and ventilators side or top or centre hung with beading and all members of standard rolled steel sections joints mitred and flash butt welded and sash bars tenoned and riveted with 15 into 3mm lugs 10cm long embedded in cement concrete blocks 15 into 10 into 10cm of 1isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20mm nominal size or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required including providing and fixing of hinges pivots float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design complete as per the direction of eic. 22 providing and fixing tiron frames for doors windows and ventilators of mild steel tee ections joints mitred and welded with 15 into 3 mm lugs 10cm long embedded in cement concrete blocks 15 into 10 into 10 cm of 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer complete as per the direction of eic. 23 providing and fixing ms fan clamp type i or ii of 16mm dia ms bar bent to shape with hooked ends in rcc slabs beams during laying including painting the exposed portion of loop all as per standard design complete complete as per the direction of eic. 24 cement concrete flooring 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate finished with a floating coat of neat cement including cement slurry but excluding the cost of nosing of steps etc. complete complete as per the direction of eic. 40mm thick with 20 mm nominal size stone aggregate. 25 providing and laying ceramic glazed floor tiles 300 into 300 mm thickness to be specified by the manufacturer of 1st quality conforming to is 15622 of approved make in colours such as white ivory grey fume red brown laid on 20mm thick cement mortar 1 isto 4 1 cement isto 4 coarse sand including pointing the joints with white cement and matching prgment etc. complete as per the direction of eic. 26 providing and fixing 1st quality ceramic glazed wall tiles conforming to is 15622 of approved make in all colours shades except burgundy bottle green black of any size as approved by eic in skirting, risers of steps and dados over 6 mm thick bed of cement mortar 1 isto 3 1 cement isto 3 coarse sand and jointing with grey cement slurry at the rate 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 27 providing and fixing on wall face pvc rain water pipes or toilet pipe including ms holder bat clamps wooden pegs etc with accessories like ci grating plain bend head shoes etc including filling joints with spun yarn soaked in neat cement slurry and cement mortar 1 isto 2 1 cement isto 2 fine sand including a coat of primer cost of all materials labour tools and tackles etc complete complete as per the direction of eic. upvc pipes working pressure 4 kgpersqm single socketed pipe 110 mm dia 28 12mm cement plaster of mix 1 isto 4 1 cement isto 4 fine sand complete as per the direction of eic. 29 15mm cement plaster on the rough side of single or half brick wall of mix 1 isto 6 1 cement isto 6 fine sand complete as per the direction of eic. 30 6mm cement plaster 1 isto 3 1 cement isto 3 fine sand finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of rcc slabs and beams complete as per the direction of eic. 31 supplying and applying two 2 coats of white wash over old work at various elevations including preparation of surfaces cleaning etc. complete with all materials labour tools and tackle etc scaffolding work as per specifications and directions of eic. composition water at the rate 5 litres per kg of lime for making cream. fevicol ddl at the rate 4 gm per litre of lime cream. robin blue at the rate 2gm. per kg lime. 32 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade new work two or more coats over and including priming coat with cement primer. 33 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade approved brand and manufuacturer and ist quality 10 yrs like asian berger nerolac ici dulux old work one or more coats applied at the rate 0.83 ltr per10 sqm. 34 applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work second coat 35 painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work. 36 providing groove of uniform size in plastered surface as per approved pattern using wooden battens bnailed to the under layer including of wooden battens repairs to the edges of the plaster panel and finishing the groove complete as per specifications and direction of eic including all materials labour tools and tackles etc complete. 12mm into 12mm 37 demolishing cement concrete manually or by mechanical means including disposal of material within 50 metres lead as per direction of eic. 1 isto 3 isto 6 or richer mix 38 demolishing brick work in cement mortar including tacking of serviceable material and disposal of unserviceable material within 50 metres lead including all materials labour tools and tackles etc complete 39 making plinth protection 50mm thick of cement concrete 1 isto 3 isto 6 1 cement isto 3 coarse sand isto 6 graded stone aggregate 20 mm nominal size over 75 mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 40 providing and fixing water closet squatting pan indian type wc pan with 100mm sand cast iron p or s trap 10 litre low level white pvc flushing cistern with manually controlled device handle lever conforming to is 7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required white vitreous china orissa pattern wc pan of size 580 into 440mm with integral type foot rests. 41 providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors ci trap and bend 100 mm inlet and 75 mm outlet sand cast iron sands as per is1729 42 providing and fixing 600 into 450 mm beveled edge mirror of superior glass of approved quality complete with 6mm thick hard board ground fixed to wooden cleats with c p brass screws and washers complete 43 providing & fixing 600 into 120 into 5mm glass shelf with edges round of supported on anodised aluminium angle frame with c p brass brackets and guard rail complete fixed with 40mm long screws rawl plugs etc. complete 44 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm long towel rail with total legth of 645mm width 78mm and effective height of 88mm weighing not less than 190 gms. 45 providing and fixing 2mm thick plaster of paris 46 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 15mm dia nominal bore 47 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 20mm dia nominal bore 48 providing and fixing gi pipe complete with gi fittings and clamps i or c cutting and making good the walls etc. complete as per the direction of eic. 25mm dia nominal bore 49 providing and fixing gun metal gate valve with ci wheel of approved quality screwed end 25 mm nominal bore 50 providing and fixing cp brass shower rose with 15 or 20mm inlet 100 mm diameter make emco 51 providing and fixing c p brass bib cock of approved quality make emco 15mm nominal bore 52 constructing masonry chamber 60 into 60 into 75cm inside with 75 class designation brick work in cement mortar 1 isto 4 1 cement isto 4 coarse sand for sluice valve with ci surface box 100mm top diameter 160 mm bottom diameter and 180mm deep inside with chained lid and rcc top slab 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20 mm nominal size necessary excavation foundation concrete 1 isto 5 isto 10 1 cement isto 5 fine sand isto 10 graded stone aggregate 40mm nominal size and inside plastering with cement mortar 1 isto 3 1 cement isto 3 coarse sand 12mm thick finished with a floating coat of neat cement complete as per standard design with fps bricks complete as per the direction of eic. 53 providing & fixing c p brass stop cock concealed of standard design and of approved make conforming to is 8931.15mm nominal bore. 54 making soak pit 2.5 m diameter 3.0 metre deep with 45 into 45cm dry brick honey comb shaft with bricks of class designation 75 and sw drain pipe 100mm diameter 1.8m long complete as per standard design with fps bricks 55 grading roof for water proofing treatment with cement concrete 1 isto 2 isto 4 1 cement isto 2 coarse sand isto 4 graded stone aggregate 20mm nominal size 56 providing and placing on terrace at all floor levels polyethylene water storage tank isi 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflor pipes but without fittings and the base support for tank.make sintex 57 providing and fixing wash basin with ci brackets 15mm cp brass pillar taps 32mm cp brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever required white vitreous china wash basin size 630 into 450 mm with a pair of 15mm c. p brass pillar taps complete as per the direction of eic. 58 wiring for circuit or submain wiring along with earth wire with the following sizes of frls pvc insulated copper conductor single core cable in surface or recessed medium class pvc conduit as required 2 into 6 sqmm plus 1 into 6 sq mm earth wire 59 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc.as required 60 wiring for light or power plug with 2 into 4 sqmm frls pvc insulated copper conductor single core cable in surface ot recessed medium class pvc conduit alongwith 1 no. 4 sqmm frls pvc insulated copper conductor single core cable for loop earthing as required 61 supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc. as required 62 3 pin 5or6 a socket outlet 63 6 pin 15or16 a socket outlet 64 supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 65 supplying and fixing following size or modules gi box alongwith modular base and cover plate for modular switches in recess etc. 1 or 2 module 75 mm into 75 mm 66 4 module 125 mm into 75 mm 67 8 module 125 mm into 125 mm 68 supplying and fixing 3 pin 5 a ceiling rose on the existing junction box or wooden block including connections etc. as required 69 erection of wall bracket or ceiling fittings of all sizes and shapes containing upto two gls lamps per fitting complete with all accessories including connections etc. as required 70 installation testing and commissioning of pre wired fluorescent fitting or compact fluorescent fitting of all types complete with all accessories and tube etc. directly on ceiling or wall including connections with 1.5 sqmm fr pvc insulated copper conductor single core cable and earthing etc. as required 71 providing and fixing following rating and breaking capacity mccb in existing cubicle panel board including drilling holes in cubicle panel making connections etc. as required 100 a 16 ka 72 supplying and fixing 5 a to 32 a rating 240or415 v 10 ka c curve miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections testing and commissioning etc. as required single pole 6 amp 73 supplying and fixing following rating four pole three phase and neutral 415 v residual current circuit breaker rccb having a sensitivity current 30 ma in the existing mcb db complete with connections testing and commissioning etc. as required 63 amps 74 earthing with gi earth pipe 4.5 meter long 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required 75 supplying and laying 25 mm into 5 mm g.i strip at 0.50 meter below ground as strip earth electrode including connection or terminating with gi nut bolt spring washer etc. as required. jointing shall be done by overlapping and with 2 sets of g.i nut bolt and spring washer spaced at 50 mm 76 fixing of lightning conductor finial single prong with base plate including holes etc. complete as required 77 providing and fixing g.i tape 20 mm into 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.for horizontal run 78 providing and fixing g.i tape 20 mm into 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. for vertical run 79 laying of one number pvc insulated and pvc sheathed or xlpe power cable of 1.1 kv grade of following size direct in ground including excavation sand cushioning protective covering and refilling the trench etc. as required upto 35or50 sq. 80 excavation for cable trench / foundation in soft soil including dressing of sides and ramming of ottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 meter 81 supply of 46inch 1200 mm sweep energy efficient 5 star high speed ceiling fan with electronic regulator size 150 watt make crompton complete in all respect as per specification and direction of eic. high breeze colour brown or ivopry 82 supply 1 into 40w led tube light make philips type bn 550 wled 20 to 300 led linea 83 supply and fixing of single phase energy meter kwh with box of model no. 1plcd meter 5 to 30a catno. wm1018csdl0bok make land t...
33857224 repair and maintenance of 33/3.3kv o/h line from reg. sub station to cpp plant, earth wire restringing with earthing connection, earth pit and pole painting etc....
33843070 repair and maintenance of 33 / 3.3kv o / h line from reg. sub station to cpp plant, earth wire restringing with earthing connection, earth pit and pole painting etc....
33461609 diversion of 6.6 kv shovel feeder no ( 1 ) clear the area drill m / c and dragline m / c power supply dragline m / c drill m / c 602 it patch ( b ) extension, braekdown repairing of 6.6 kv benidih feeder power supply 4000 gpm pump deco patch and dismantling of idle 6.6 kv benidih feeder ( c ) extension of 220v l.t o / h line deco patch and braekdown repairing of 220v l.t o / h line d / l face 9 seem of abocp mine. 1 6.6kv sfi part i for erection job 2 erection of ht pipe pole / rail pole 3 transportation of pole 4 dismantling of ht pipe pole jocp face 5 erection ofiron material 6 supply anderection ofiron material 7 erection of stay set 8 supply and erection of stay set 9 erection of earth wire 10 erection of disc insulator 11 erection of pin insulator 12 jampharing of cable lead 13 jampharing of o / h line conductor 14 construction of earth pit 15 laying hanging on pole for armored cable 16 drawing of acsr dog conductor 17 dismantling of rail pole 18 transportation of pole side of safe side abocp mine 19 dismantling of iron material 20 disconnaction of cable lead 21 disconnaction of o / h line jumpher 22 dismantling of earth wire 23 dismantling of pin insulator 24 dismantling of disc insulator 25 dismantling of acsr / dog conductor 26 part i 6.6 kv benidih feeder for erection job 27 erection of ht pipe pole / rail pole 28 re eretion of pipe pole 29 transportation of pole 30 erection ofiron material 31 supply anderection ofiron material 32 erection of stay set 33 supply and erection of stay set 34 erection of erath wire 35 supply and erection of earth wire 36 erection of pin insulator 37 erection of disc insulator 38 jampharing of o / h line conductor 39 jampharing of cable lead 40 laying hanging on pole for armored cable 41 drawing of acsr dog conductor 42 dismantling of rail pole 43 dismantling of iron material 44 transportation of pole side of safe side abocp mine 45 dismantling of disc insulator 46 dismantling of pin insulator 47 disconnection of cable lead 48 disconnaction of o / h line jumpher 49 dismantling of earth wire 50 dismantling of stay set 51 dismantling of ab switch 52 dismantling of acsr / dog conductor 53 220v l.t o / h line 54 erection of rail pole / ht pipe pole 55 re eretion of pipe pole 56 transpotation of pole 57 erection ofiron material 58 supply anderection ofiron material 59 erection of stay set 60 supply and erection of stay set 61 erection of shackle insulator 62 supply of shackle / pin insulator 63 jumpharing of o / h line conductor 64 drawing of acsr rabbit conductor 65 dismantling of ht pipe pole / rail pole 66 dismantling of stay set 67 dismantling og shackle / pin insulator 68 dismantling of s.v lamp set 69 disconnection of o / h line jumpher 70 dismantling of iron material 71 dismantling of acsr rabbit conductor 72 total impact of gst for the purpose of ctc...
33447164 monsoon maintenance erection of earth wire and cradle guard of 11kv kuya feeder...
33447008 monsoon maintenance earth wire and cradle guard errection of 11kv bera bastacolla feeder....
33442564 stringing of acsr rabbit conductor replacing g.i. earth wire and making of earth pit at different location in mines...
33426410 stringing of conductor and making of earth pit stringing of acsr rabbit conductor replacing g.i. earth wire and making of earth pit at different location in mines...
33058669 diversion, extension, dismantling of 6.6 kv d / l feeder for advancing of face power supply shovel m / c and drill m / ccontra ding jocp ocb of abocp b ) dismantling, erection of 220v l.t o / h line clear the area advancing of face lighting for coal dump ob dump houl road jocp mine of abocp. erection of 6.6 kv d / l feeder part i 2 erection of ht pipe pole / rail pole 3 re erection of ht pipe pole 4 transportation of pole 5 erection of iron material 6 supply and erection of iron material 7 erection of stay set 8 supply and erection of stay set 9 erection of pin insulator 10 erection of disc insulator 11 construction of earth pit 12 erection of earth wire 13 supply and erection of earth wire 14 supply and erection of cradle guard 15 transportation, laying hanging and 16 jumphering of cable lead 17 jumphering of o / h line conductor 18 drawing of acsr dog conductor 19 part ii dismantling work of 6.6 kv 20 dismantling of ht pipe pole / rail pole 21 transportation of pole side 22 dismantling of iron material 445kg+ 335 kg 23 dismantling of stay set 24 dismantling of earth wire 25 disconnection of cable lead 26 dismantling of pin insulator 27 disconnection of disc insulator 28 disconnection of acsr dog conductor 29 220v l.t o / h line 30 dismantling of pipe pole 31 transportation of pole 32 dismantling of iron material 33 dismantling of shakle / pin insulator 34 disconnection o / h line jumpher 35 dismantling of s.v lump set 36 dismantling of acsr rabbit conductor 37 erection of pipe pole 38 erection of iron material 39 supply and erection of iron material 40 supply and erection of stay set 41 fitting of s.v lump set 42 jumphering of o / h line conductor 43 supply and erection of cradle guard 44 erection of shakle / pin insulator 45 drawing of acsr rabbit conductor 46 total impact of gst for the purpose of ctc...
33056603 dismantling, erection, breakdown repairing damaged by blasting bolder power supply dm 3 / 521, dm 3 / 522, 4000 gpm pump jocp of abocp. ( b ) erection, breakdown repairing of 220v l.t o / h line lighting for jocp face 4000 gpm pump and haul road jocp of abocp mine. ( c ) dismantling, erection of 6.6 kv d / l feeder, 220v l.t o / h line for marching of dm 3 / 522 midil banch jocp of abocp. ( d ) supply and erection of cradle guard for safety purpose 11kv o / h line 6.6 kv o / h line, 440v / 220v lt o / h line defferent place of jocp mine of abocp. 1 6.6 kv d / l feeder 2 erection of pipe pole 3 transpotation of pole 4 re erection of pipe pole / rail pole 5 erection ofiron material 6 supply anderection ofiron material 7 erection of stay set 8 supply and erection of stay set 9 erection of earth wire 10 supply and erection of eaarth wire 11 supply and erection of cradle guard 12 construction of earth pit 13 transportation laying hanging on pole for amored cable 14 jampharing of cable lead 15 jampharing of o / h line conductor 16 erection of disc insulator 17 erection of pin insulator 18 dismantling of rail pole 19 transportation of rail pole 20 dismantling of iron material 21 dismantling of stay set 22 dismantling of earth wire 23 disconnection of cable lead 24 disconnection of o / h line jumpher 25 dismantling of damaged cradle guard 26 dismantling of pin insulator 27 dismantling of disc insulator 28 dismantling of acsr / dog conductor 29 drawing of acsr dog conductor 30 220v l.t o / h line 31 erection of pipe pole 32 re erection of pipe pole 33 erection ofiron material 34 supply anderection ofiron material 35 supply and erection of stay set 36 erection of shackle pin insulator 37 supply of shackle pin insulator 38 supply and erection cradle guard 39 fitting of s.v lamp set 40 jumpharing of o / h line jumphar 41 dismantling of pipe pole 42 dismantling ofiron material 43 disconnection of o / h line jumpher 44 dismantling of s.v lamp set 45 dismantling of damaged cradle guard 46 dismantling of shackle pin insulator 47 dismantling of acsr rabbit conductor 48 drawing of acsr rabbit conductor 49 marching of dm 3 / 522, dismantling and erection of 6.6 kv / 220v o / h line 50 dismantling of acsr dog conductor 51 dismantling of disc insulator 52 dismantling of cradle guard 53 disconnection of cable lead 54 disconnection of o / h line jumpher 55 re jupharing of o / h line conductor 56 re jupharing of cable lead 57 transpotation laying hanging on pole for armored cable 58 erection of disc insulator 59 erection of ascr dog conductor 60 220v l.t o / h line 61 dismantling of ascr robbit conductor 62 dismantling of shackle pin insulator 63 disconnection of o / h line jumpher 64 re jupharing of o / h line conductor 65 erection of shackle pin insulator 66 drawing of acsr rabbit conductor 67 supply and erection of cradle guard 11kv, 6.6 kv, 440v / 220v lt o / h line for safety porpose 68 supply and eretion of cradle guard 11kv o / h line 69 supply and erection of earth wire 70 erection ofiron material 71 supply anderection ofiron material 72 supply and eretion of cradle guard 6.6 kv o / h line 73 supply and erection of earth wire 74 erection ofiron material 75 supply and erection of earth wire 440v / 220v lt o / h line 76 supply and eretion of cradle guard 77 erection ofiron material 78 supply anderection ofiron material 79 total impact of gst for the purpose of ctc...
32703378 maintenance of 33kv tie line with replacement of 01 no. damaged tp structure and earth wires of 33kv oh tie line in between new and old substation of kdh ocp, nk area m ...
32694711 supplying, installation, testing and commissioning submersible pump set for rural water supply scheme manushmudya, pumping plant. under d.w and s mechanical division, jamshedpur 1 supply of submersible pump set suitable for 6 dia bore well running with 3 phase415± 10% volts50 c / s 2900 rpm having discharging capacity 2600 gph against total head of 60 meters with noryl / g.m impeller consists of following accessories ( a ) 2½ dia g.i column pipe 200 ( 10 long both end threaded one end fitted socket and other end covered by plastic ) ( b ) 3 core flat copper cable 4 mm² 1 coil ( c ) m.s clamp 2½ dia 2 pairs ( d ) c.i.d.f sluice valve 2½dia 1no. ( e ) ) c.i.d.freflexvalve 2½dia 1no. 2 supplying and fitting cubical type duly painted control panel boardconsisting 32 amps. tpn mccb inbuilt single phase preventor and suitable forstar delta automatic starter water level guard with suitable length and size of wire phase indicating bulb in three different colour suitable voltmeter and ampere meterwith selector switch make l&t / havell;s 3 chemical earthing3 metersand80 mm hole size with electrode and chemical compound etc. with watering pipe and locking arrangement including soldering, riveting, jointing g.i flat 50 mm x 6 mm to all equipments. 4 supplyingtriple spur gear type 3 tonne capacitychain pulley block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 5 renovation of light wiring inside & out side pump chamber by doing short point light wiring 4 point long point light wiring 4 points, 150 watt led street light complete set 2 nos., 36 watt cfl 4 nos. etc. all including labour charges all complete 6 supplying and making tripod ( 14x 65 mm c.i pipe ) hanging chain pulley block 7 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 25 mm² x 3½ core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved. from transformer to p / house via gangway. 8 supplying installation testing and commissioning of 30 kva servo controlled automatic voltage stabilizer oil cooled power line / ipc / servokon make suitable for output voltage of 415 volt ± 1% under input voltage range of 280 450 volts ( phase to phase ) 3 phase, 50 hz, with copper wound transformer. the stabilizer shall function satisfactory even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should have indicator, alarm, voltmeterand auto / manual selector switch for measuring input and output voltage, raise / low push buttons etc. suitable capacity terminationstrip and bus bars for incoming and outgoing cable should be provided. all three phase shall be independently monitored and corrected. following protections and indications shall be incorporated :over voltage / under voltage single phasing cut off conductor with electronic output sensing unit. 9 supplying and fixing 100 amp. 415± 15% voltage change over switch, havells / l & t make 10 transformer oil for the above stabilizer of best make up to mark. 11 supplying, installation, testing & commissioningof outdoor type 63 kva 11 / 0.433 kva copper wound distribution transformer with off load tap changer 12.5% to 2.5% in step of 2.5%, continuously rated for three phase, 50 hz, full load and temperature rise not exceeding 45 degree centigrade by thermometer in oil and 50 degree centigrade by the resistance in winding after continuous, run atfull load rating, the transformer should have oil immersed winding having vector group of 0.4 / 11, ht side connected in delta & lt side connected in star with neutral brought out connected. the transformer should have power terminal bushing arrangement on ht side & cable box in lt side with standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. all complete with all materials make – indian transformer / synergy / banglabijulee / kirloskar for ruralwatersupply p / pmanushmudia....
32596889 tender forpreventive maintenance work of 132/33 kv grid sub station, deoghar and patrolling work (tree pruning repositioning of earth wire, checking, tightening & positioning of fasteners, all jumpers etc and backfilling of soil erosion of tower legs along the corridor) of 132 kv transmission line (117 km) under transmission sub division, deoghar for the period of 30 days....
32534073 e quotation for rate of materials for schedule rate jharkhand under d w and s division, medininagar 2022 23.= 1 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) 2 gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) 3 jute ( m337 ) 4 g.m. ferrules ( m922 ) 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 stop cocks ( m923 ) 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 g.m. full way valve ( m924 ) 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 g.m. non return valve verticle ( m925 ) 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 g.m. non return valve horizontal ( m926 ) 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 cocks ( m927 ) 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 chromium plated brass fittings ( m928 ) 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 connection pipe ( m929 ) 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 mirrors ( m931 ) 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) 194 ( b ) do 450 mm x 125 mm do 195 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) 198 c.p. liquid soap solution holder ( m935 ) 199 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) 205 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) 206 ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) 218 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 drain board. ( m944 ) 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 h.c.i. pipes ( m945 ) 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 h.c.i. fittings. ( m946 ) 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 c.i. cover with frame for manhole and inspection chamber. ( m947 ) 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 c.i. bracket pair for w.h.b. ( m948 ) 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) 311 rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) 312 pig lead ( m953 ) 313 yarn ( m954 ) 314 rubber gasket for c.i pipe of good quality ( m955 ) 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 cotton waste ( m956 ) 334 asbestos suta ( gland packing ) ( m957 ) 335 solvent cement ( m958 ) 336 hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) 337 cp & pvc fitting ( m960 ) 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 c.i special & pvc pipes ( m962 ) 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) 385 rcc esr ( m1030 ) 386 designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. 387 notes 388 the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) 389 the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. 390 for design having more than 6 columns, suitable bracing is obligatory. 391 plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed 392 irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 393 these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. 394 staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 395 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 396 all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 397 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 398 the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . 399 for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. 400 below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. 401 the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. 402 the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 403 12 to 16 m staging 2% per metre 404 16 to 20 m staging 3% per metre 405 20 m and above 4% per metre 406 for 17 m staging height, percentage calculation will be like below : 407 12 to 16 m 4 x 2 = 8% 408 16 & 17 m 1 x 3% = 3% total = 11% 409 for 21 m staging height, percentage calculation will be like below : 410 12 to 16 m 4 x 2 = 8% 411 16 to 20 m 4 x 3% = 12% 412 20& 21 m 1 x 4% = 4% total = 24% 413 following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . 414 notes 415 conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. 416 conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. 417 rates for rcc esrs 418 upto 25, 000 litres 419 cost of 25, 000 litres capacity 420 add for capacity above 25, 000 upto 50, 000 litres 421 cost of 50, 000 litres capacity 422 add for capacity above 50, 000 upto 75, 000 litres 423 cost of 75, 000 litres capacity 424 add for capacity above 75, 000 upto 1, 00, 000 litres 425 cost of 1, 00, 000 litres capacity 426 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 427 cost of 1, 50, 000 litres capacity 428 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 429 cost of 2, 00, 000 litres capacity 430 add for capacity above 2, 00, 000 upto 2, 50, 000 litres 431 cost of 2, 50, 000 litres capacity 432 add for capacity above 2, 50, 000 upto 3, 00, 000 litres 433 cost of 3, 00, 000 litres capacity 434 add for capacity above 3, 00, 000 upto 4, 00, 000 litres 435 cost of 4, 00, 000 litres capacity 436 add for capacity above 4, 00, 000 upto 5, 00, 000 litres 437 cost of 5, 00, 000 litres capacity 438 add for capacity above 5, 00, 000 upto 7, 50, 000 litres 439 cost of 7, 50, 000 litres capacity 440 add for capacity above 7, 50, 000 upto 10, 00, 000 litres 441 cost of 10, 00, 000 litres capacity 442 add for capacity above 10, 00, 000 upto 15, 00, 000 litres 443 cost of 15, 00, 000 litres capacity 444 add for capacity above 15, 00, 000 upto 20, 00, 000 litres 445 cost of 20, 00, 000 litres capacity 446 rcc gsr and sump ( m1031 ) 447 designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. 448 anti –termite treatment shall be given for under ground portion of the structure. 449 notes 450 the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) 451 only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. 452 entire structure shall be in m 300 only. 453 the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 454 the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. 455 the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. 456 g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. 457 for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. 458 cost of pump house is not included in these rates. 459 above rates are applicable for seismic zones 2, 3 and 4. 460 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 461 10% shall be added for sump if over head pump house is proposed. 462 note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. 463 rates for rcc gsrs and sumps 464 upto 25, 000 litres 465 cost of 25, 000 litres capacity 466 add for capacity above 25, 000 upto 50, 000 litres 467 cost of 50, 000 litres capacity 468 add for capacity above 50, 000 upto 75, 000 litres 469 cost of 75, 000 litres capacity 470 add for capacity above 75, 000 upto 1, 00, 000 litres 471 cost of 1, 00, 000 litres capacity 472 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 473 cost of 1, 50, 000 litres capacity 474 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 475 cost of 2, 00, 000 litres capacity 476 add for capacity above 2, 00, 000 upto 3, 00, 000 litres 477 cost of 3, 00, 000 litres capacity 478 add for capacity above 3, 00, 000 upto 5, 00, 000 litres 479 cost of 5, 00, 000 litres capacity 480 add for capacity above 5, 00, 000 upto 10, 00, 000 litres 481 cost of 10, 00, 000 litres capacity 482 addforcapacityabove10, 00, 000upto15, 00, 000 litres 483 cost of 15, 00, 000 litres capacity 484 add for capacity above 15, 00, 000 litres 485 note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. 486 unconventionalwater treatment plant ( m1032 ) 487 designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. 488 aeration fountain 489 inlet arrangements 490 mixing channel with ventury flume and flow measuring arrangement 491 inlet channel 492 flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes 493 tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance 494 rapid sand gravity filters all valve shall be glandless. 495 filter house 496 chemical house 497 alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 498 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. 499 tcl solution tank with mixing, carrying and dosing arrangement with piping. 500 bypass arrangement 501 external and internal electrification 502 laboratory equipments 503 wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. 504 wash water pumps with 100% standby 505 air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. 506 pure water sump of capacity equal to 1 hourpumping capacity. 507 pure water pump house over the sump / by the side of sump. 508 drainage arrangements 509 alum store 510 sanitary block with necessary water supply and drainage arrangements and internalwbm roads. 511 these rates are applicable for seismic zones 2, 3 and 4. 512 rates given below are inclusive of uplift pressure if any and dewatering during the entire work. 513 all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. 514 unconventional treatment plants less than 1 mld capacity shall not be constructed. 515 all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . 516 note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. 517 unconventional water treatment plant 518 fixed cost for 1 mld 519 add for capacity above 1 mld upto 2 mld 520 cost of 2 mld treatment plant 521 add for capacity above 2 mld upto 3 mld 522 cost of 3 mld treatment plant 523 conventionalwater treatment plant ( m1033 ) 524 designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . 525 aeration fountain plan are a not less than 0.625 square metre per mld 526 ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) 527 flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. 528 flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. 529 clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. 530 rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. 531 filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. 532 wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. 533 wash water pumps capacity to fill water tank in 1 hour with 100% standby. 534 air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . 535 chemical house in two storeys 536 ground floor to accommodate 7 days alum requirement and sundry storage. 537 first floor to accommodate alum and lime tanks.etc. 538 solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. 539 pure water sump and sump house. 540 capacity of sump – one hour of designed flow. 541 pump house pump house of required size over the sump or by the side. 542 store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. 543 vacuum feed type chlorinators make tobe approved by mjp. 544 conforming to i.s. 10533 a part ii 1983 545 rate for withdrawal 546 temperature kg. of chlorine discharge degree c per day ( cylinders ) 547 45 67 tonnes 548 10 6.359.50 110 549 15 10.75 16.10130 550 20 14.50 21.24254 551 27&above18.70 28.12315 552 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 553 100% standby shall be provided. 554 by pass arrangements c.i. or m.s. pipes. 555 disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe 556 for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete 557 drainage arrangements – rcc pipes up to plot boundary. 558 electrical installation – both internal and external including entire plant area. 559 laboratory equipment –as per requirement ( to be specified during tendering ) . 560 sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. 561 administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. 562 rates given below are inclusive of up lift pressure if any and dewatering during entire work. 563 all pipes condutes channels with20%overloading 564 these rates are applicable for seismic zones 2, 3 and 4. 565 all rcc structures shall be constructed in m 300. 566 note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . 567 conventional water treatment plant 568 above3 mld to upto 5 mld 569 cost of 5 mld treatment plant 570 add for capacity above 5mld upto 10 mld 571 cost of 10 mld treatment plant 572 add for capacity above 10 mld upto20 mld 573 cost of 20 mld treatment plant 574 add for capacity above 20 mld upto 50 mld 575 cost of 50 mld treatment plant 576 add for capacityabove 50 mld upto 100 mld 577 cost of 100 mld treatment plant 578 add for capacity above 100 mld 579 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) 580 300 mm dia for gpt 581 400 mm dia for hygpt 582 hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) 583 from 0 50 meter 584 from 51 125 meter 585 dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) 586 drillig upto 30 mtr depth below g. l. in rural area 587 drilling beyond 31 mtr upto 60 mtr below g. l. in rural area 588 trenchless ( m1038 ) 589 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 590 from 900 mm to 1000 mm dia 591 in soft soil 592 in hard soil 593 in sandy soil 594 in stone soil 595 from 1000 mm to 1200 mm dia 596 in soft soil 597 in hard soil 598 in sandy soil 599 in stone soil 600 above 1200 mm to 1500 mm dia 601 in soft soil 602 in hard soil 603 in sandy soil 604 in stone soil 605 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 606 upto 300 mm dia 607 in soft soil 608 in hard soil 609 in sandy soil 610 in stone soil 611 above300 mm to 450 mm dia 612 in soft soil 613 in hard soil 614 in sandy soil 615 in stone soil 616 above 450 mm to 600 mm dia 617 in soft soil 618 in hard soil 619 in sandy soil 620 in stone soil 621 above 600 mm to 900 mm dia 622 in soft soil 623 in hard soil 624 in sandy soil 625 in stone soil 626 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 627 upto 300 mm dia 628 in soft soil 629 in hard soil 630 in sandy soil 631 in stone soil 632 above300 mm to 450 mm dia 633 in soft soil 634 in hard soil 635 in sandy soil 636 in stone soil 637 above 450 mm to 600 mm dia 638 in soft soil 639 in hard soil 640 in sandy soil 641 in stone soil 642 above 600 mm to 900 mm dia 643 in soft soil 644 in hard soil 645 in sandy soil 646 in stone soil 647 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) 648 without byepass arrangement pn 1 649 50 mm 650 65 mm 651 80 mm 652 100 mm 653 125 mm 654 150 mm 655 200 mm 656 250 mm 657 300 mm 658 350 mm 659 400 mm 660 450 mm 661 500 mm 662 600 mm 663 700 mm 664 750 mm 665 800 mm 666 900 mm 667 1000 mm 668 1100 mm 669 1200 mm 670 with byepass arrangement pn 1 671 50 mm 672 65 mm 673 80 mm 674 100 mm 675 125 mm 676 150 mm 677 200 mm 678 250 mm 679 300 mm 680 350 mm 681 400 mm 682 450 mm 683 500 mm 684 600 mm 685 700 mm 686 750 mm 687 800 mm 688 900 mm 689 1000 mm 690 1100 mm 691 1200 mm 692 without byepass arrangement pn 1.6 693 50 mm 694 65 mm 695 80 mm 696 100 mm 697 125 mm 698 150 mm 699 200 mm 700 250 mm 701 300 mm 702 350 mm 703 400 mm 704 450 mm 705 500 mm 706 600 mm 707 with byepass arrangement pn 1.6 708 50 mm 709 65 mm 710 80 mm 711 100 mm 712 125 mm 713 150 mm 714 200 mm 715 250 mm 716 300 mm 717 350 mm 718 400 mm 719 450 mm 720 500 mm 721 600 mm 722 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 723 with byepass arrangement pn 1 724 50 mm 725 65 mm 726 80 mm 727 100 mm 728 125 mm 729 150 mm 730 200 mm 731 250 mm 732 300 mm 733 350 mm 734 400 mm 735 450 mm 736 500 mm 737 600 mm 738 700mm 739 750 mm 740 800 mm 741 900 mm 742 1000 mm 743 1100 mm 744 1200mm 745 without byepass arrangement pn 1 746 50 mm 747 65 mm 748 80 mm 749 100 mm 750 125 mm 751 150 mm 752 200 mm 753 250 mm 754 300 mm 755 350 mm 756 400 mm 757 450 mm 758 500 mm 759 600 mm 760 700mm 761 750 mm 762 800 mm 763 900 mm 764 1000 mm 765 1100 mm 766 1200mm 767 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 768 without byepass arrangement pn 1.6 769 50 mm 770 65 mm 771 80 mm 772 100 mm 773 125 mm 774 150 mm 775 200 mm 776 250 mm 777 300 mm 778 350 mm 779 400 mm 780 450 mm 781 500 mm 782 600 mm 783 700mm 784 750 mm 785 800 mm 786 900 mm 787 1000 mm 788 1100 mm 789 1200mm 790 with byepass arrangement pn 1.6 791 50 mm 792 65 mm 793 80 mm 794 100 mm 795 125 mm 796 150 mm 797 200 mm 798 250 mm 799 300 mm 800 350 mm 801 400 mm 802 450 mm 803 500 mm 804 600 mm 805 design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . ( m1040 ) 806 dia 06 inch ( 150 mm ) 807 id 153 mm od 167 mm 808 screen thickness 07 mm 809 slot 1.00 mm 810 moc lowcarbon galvenised steel 811 length 5 mtr. 812 dia 08 inch ( 200 mm ) 813 id 205 mm od 221mm 814 screen thickness 08 mm 815 slot 1.00 mm 816 moc lowcarbon galvenised steel 817 length 5 mtr. 818 dia 10 inch ( 250 mm ) 819 id 256 mm od 276mm 820 screen thickness 10 mm 821 slot 1.00 mm 822 moc lowcarbon galvenised steel 823 length 5 mtr. 824 dia 12 inch ( 300 mm ) 825 id 306 mm od 326 mm 826 screen thickness 10 mm 827 slot 1.00 mm 828 moc lowcarbon galvenised steel 829 length 5 mtr. 830 dia 14 inch ( 350 mm ) 831 id 338 mm od 363 mm 832 screen thickness 12.5 mm 833 slot 1.00 mm 834 moc lowcarbon galvenised steel 835 length 5 mtr. 836 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) 837 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) 838 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) 839 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) 840 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) 841 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) 842 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) 843 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) 844 supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) 845 supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) 846 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) 847 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) 848 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) 849 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) 850 packaged lamella clarified type wtp with mgf capacity in mld. 851 0.2 852 0.3 853 0.4 854 0.5 855 0.6 856 pumps ( m1055 ) 857 supplying100 mm dia submersible pump sets confirming to is 8034 and motor confirming to is 9283. pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene / noryl impeller. motor suitable for working on 415v+10%, 3ph, 50 hz, a.c. supply with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. pump shall have suitable outlet as per manufacturers design. anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump. 858 submersible pump set 100 mm dia ( with polypropylene / noryl impeller ) up to 20 stages 859 1 h.p. 860 1.5hp 861 2 hp 862 2.5 hp 863 3.0 hp 864 4.0 hp 865 5.0 hp 866 supply rate should be increased by rs 200 / per stage for pump with more than 20 stages 867 submersible pump 150 mm dia ( with bronze impeller ) up to 8 stages 868 1.5 hp 869 2.0 hp 870 3.0 hp 871 4.0 hp 872 5.0 hp 873 6.0 hp 874 7.5 hp 875 supply rate should be increased by rs 600 / per stage for pump with more than 8 stages 876 submersible pump 150 mm dia ( with bronze impeller ) up to 12 stages 877 8.0 hp 878 9.0 hp 879 10.0 hp 880 11.0 hp 881 12.5 hp 882 15.0 hp 883 supply rate should be increased by rs 600 / per stage for pump with more than 12 stages 884 submersible pump 150 mm dia ( with bronze impeller ) up to 20 stages 885 17.5 hp 886 20.0 hp 887 25 hp 888 1 ) supply rate should be increased by rs 600 / per stage for pump with more than 20 stages for bore well only. 889 for other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump. 890 2 ) for 150 mm dia energy efficient pumps add as below 891 a. up to 8 stages : 3% on supply rate 892 b. up to 12 stages : 4% on supply rate 893 c. up to 15 stages : 5% on supply rate 894 pressure gauge ( m1056 ) 895 providing fabricating, testing and commisioning pressure vessel fabricating in m.s plate on providing foundation including epoxy paint 896 pressure gauge ( 100 mm dia ) 897 pressure gauge ( 150 mm dia ) 898 vacuum / combination gauge 899 supplyingvacuum gauge / combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia g.i. pipe. 900 vacuum / combination gauge – 100 mm dia 901 vacuum / combination gauge – 150 mm dia 902 lifting equipment ( m1057 ) 903 chain pulley block 904 supplyingtriple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 905 1 tonne capacity 906 2 tonne capacity 907 3 tonne capacity 908 hand operated circular or rectangular travelling crane ( single girder ) 909 supplyingsingle girder hand operated circular / rectangular travelling crane with 6 m lift complete with chain pulley block isi marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete. 910 3 tonne capacity 911 up to 5 m span 912 above 5 m up to 6 m span 913 above 6 m up to 8 m span 914 5 tonne capacity 915 up to 5 m span 916 above 5 m up to 6 m span 917 above 6 m up to 8 m span 918 above 8 m up to 10 m span 919 electric operated circular or rectangular travelling crane ( single girder ) 920 supplying single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class ii duty, all three motions electrically operated by suitable rating motor ip 54, control panel and down pendant control block. 921 5 tonne capacity 922 above 6 m up to 8 m span 923 above 8 m up to 10 m span 924 7.5 tonne capacity 925 above 6 m upto 8 m span 926 above 8 m up to 10 m span 927 10 tonne capacity 928 above 6 m up to 8 m span 929 above 8 m up to 10 m span 930 square bar / rail 931 providing, erecting and fixing square bar of en 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and “j” bolts. 932 50 x 50 mm ( en 8 ) 933 40 x 40 mm ( en 8 ) 934 lightening arrester, ab switch, insulators ( m1058 ) 935 lightening arrestor 936 supplying, erecting approved make thyrite type lightening arrestor suitable for h.t. supply with necessary ancillary material complete on provided cross arm and connected to overhead line. 937 suitable for 11 kv supply, distribution class 938 suitable for 22 kv supply, distribution class 939 suitable for 33 kv supply, station class 940 disc insulator 941 supplying, erecting porcelain disc type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 942 suitable for 11kv line 943 suitable for 33kv line 944 pin insulator 945 supplying, erecting porcelain pin type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 946 suitable for 11kv line 947 suitable for 33kv line 948 air break switch without earth switch 949 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 950 suitable for 11kv line 951 rocking / tilting type 952 rotating type 953 suitable for 33kv line 954 rocking / tilting type 955 rotating type 956 air break switch with earth switch 957 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 958 suitable for 11kv line 959 rotating type 960 suitable for 33kv line 961 rotating type 962 drop out fuse ( channel mounted ) 963 supplying, erecting approved make out door type drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working currentup to 50 amp, capacity completeerected on provided cross arm, each set comprising 3 units 964 suitable for 11 kv line 965 suitable for 33 kv line 966 horn gap fuse ( channel mounted ) 967 supplying, erecting approved make out door type horn gap type fuse with insulator, fuse element, with working current up to 50 amp, capacity complete erected on provided cross arm, each set comprising 3 units 968 suitable for 11 kv line 969 suitable for 33 kv line 970 transformer ( m1059 ) 971 power transformer ( with off load tap changer ) any isi mark 972 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 973 1. oil conservator with filling hole with cap and plain oil level gauge. 974 2. silica gel dehydrating breather charged with silica gel. 975 3. oil drain valve 976 4. oil filter valve 977 5. lifting eyes / hooks 978 6. two earthing terminals 979 7. diagram and rating plate 980 8. air vent 981 9. explosion vent 982 10. 100mm dia thermo meter with thermometer pocket 983 11. four bi directional plain roller. 984 power transformer 11000 / 433 volts with off load tap changer – 12.5% to +2.5% in steps of 2.5% as per bis level 2. 985 63 kva ( no load loss 180w and load loss 1235w ) 986 100 kva ( no load loss 260w and load loss 1760w ) 987 160kva ( no load loss 260w and load loss 1760w ) 988 200kva ( no load loss 500w and load loss3000w ) 989 250kvaa ( no load loss 550w and load loss3600w ) 990 315kva ( no load loss 580w and load loss 4200w ) 991 400 kva ( no load loss 715w and load loss 5000w ) 992 500 kva ( no load loss 850w and load loss 5800w ) 993 630 kva ( no load loss 1000w and load loss 7000w ) 994 750 kva ( no load loss 1500w and load loss 8000w ) 995 power transformer ( with on load tap changer ) 996 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. the oltc should be suitable for minimum 50 operations per day. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 997 1. oil conservator with filling hole with cap and plain oil level gauge. 998 2. silica gel dehydrating breather charged with silica gel. 999 3. oil drain valve 1000 4. oil filter valve 1001 5. lifting eyes / hooks 1002 6. two earthing terminals 1003 7. diagram and rating plate 1004 8. air vent 1005 9. explosion vent 1006 10. 100mm dia thermo meter with thermometer pocket 1007 11. four bi directional plain roller. 1008 12. buchholz relay 1009 13. resistance temp. detector 1010 14. marshalling box 1011 15. automatic voltage regulator ( avr ) 1012 16. remote tap changing controller ( rtcc ) 1013 transformer 11000 / 433 volts withon load tap changer – 15% to +5% in steps of 1.25% with rtcc, avr and marshalling box and other specification as per bis level 2. 1014 750 kva 1015 1000 kva 1016 1250 kva 1017 1600 kva 1018 2000 kva 1019 motors ( m1060 ) 1020 foot mounted motors tefc 1500 rpm 1021 supplyingfoot mounted tefc 1500 rpm, squirrel cage induction motor, conforming to is 325 having continuous rating suitable for operation at 415 volts + / 10%, 3 phase, 50 hz + / 3% with “f” class insulation temperature rise limited to class “b” insulation. motors conform to is 12615 with efficiency level ie3 and provided with enclosure protection class ip 55. 1022 15 kw ( 20 hp ) 1023 18.5 kw ( 25 hp ) 1024 22 kw ( 30 hp ) 1025 30 kw ( 40 hp ) 1026 37 kw ( 50 hp ) 1027 45 kw ( 60 hp ) 1028 55 kw ( 75 hp ) 1029 75 kw ( 100 hp ) 1030 90 kw ( 120 hp ) 1031 110 kw ( 150 hp ) 1032 132kw ( 180hp ) 1033 160kw ( 215 hp ) 1034 250kw ( 335 hp ) 1035 foot mounted motor tefc 1500 rpm 1036 0.75 kw ( 1hp ) 1037 1.1 kw ( 1.5 hp ) 1038 1.5 kw ( 2 hp ) 1039 2.2 kw ( 3 hp ) 1040 3.7 kw ( 5 hp ) 1041 5.5 kw ( 7.5 hp ) 1042 7.5 kw ( 10 hp ) 1043 9.3 kw ( 12.5 hp ) 1044 11 kw ( 15 hp ) 1045 aluminium cable ( m1061 ) 1046 cable 1047 aluminium conductor three core, xlpe / pvc insulated & armoured cable . 1048 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1049 3 core 2.5 sq mm 1050 3 core 4 sq mm 1051 3 core 6 sq mm 1052 3 core 10 sq mm 1053 3 core 16 sq mm 1054 3 core 25 sq mm 1055 3 core 35 sq mm 1056 3 core 50 sq mm 1057 3 core 70 sq mm 1058 3 core 95 sq mm 1059 3 core 120 sq mm 1060 3 core 150 sq mm 1061 3 core 185 sq mm 1062 3 core 240 sq mm 1063 3 core 300 sq mm 1064 3 core 400 sq mm 1065 aluminium conductor 3.5 core, xlpe / pvc insulated & unarmoured cable 1066 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three and half core, stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1067 3.5 core 25 sq mm 1068 3.5 core 35 sq mm 1069 3.5 core 50 sq mm 1070 3.5 core 70 sq mm 1071 3.5 core 95 sq mm 1072 3.5 core 120 sq mm 1073 3.5 core 150 sq mm 1074 3.5 core 185 sq mm 1075 3.5 core 240 sq mm 1076 3.5 core 300 sq mm 1077 3.5 core 400 sq mm 1078 ht aluminium three core 3.3 kve cable xlpe insulated 1079 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1080 3 core 35 sq mm 1081 3 core 50 sq mm 1082 3 core 70 sq mm 1083 3 core 95 sq mm 1084 3 core 120 sq mm 1085 3 core150sq mm 1086 3 core 185 sq mm 1087 3 core 240sq mm 1088 3 core 300 sq mm 1089 3 core 400 sq mm 1090 ht aluminium three core 6.6 kv ( ue ) / 11kv ecable xlpe insulated 1091 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1092 3 core 35 sq mm 1093 3 core 50 sq mm 1094 3 core 70 sq mm 1095 3 core 95 sq mm 1096 3 core 120 sq mm 1097 3 core150sq mm 1098 3 core 185 sq mm 1099 3 core 240sq mm 1100 3 core 300 sq mm 1101 3 core 400 sq mm 1102 ht aluminium three core 11kv ( ue ) cable xlpe insulated 1103 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1104 3 core 35 sq mm 1105 3 core 50 sq mm 1106 3 core 70 sq mm 1107 3 core 95 sq mm 1108 3 core 120 sq mm 1109 3 core150sq mm 1110 3 core 185 sq mm 1111 3 core 240sq mm 1112 3 core 300 sq mm 1113 3 core 400 sq mm 1114 aluminium conductor three core, xlpe / pvc insulated & unarmoured cable . 1115 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1116 3 core 4 sq mm 1117 3 core 6 sq mm 1118 3 core 10 sq mm 1119 3 core 16 sq mm 1120 3 core 25 sq mm 1121 3 core 35 sq mm 1122 3 core 50 sq mm 1123 3 core 70 sq mm 1124 3 core 95 sq mm 1125 3 core 120 sq mm 1126 3 core 150 sq mm 1127 3 core 185 sq mm 1128 3 core 240 sq mm 1129 3 core 300 sq mm 1130 3 core 400 sq mm 1131 copper cable ( m1062 ) 1132 cable 1133 3 core pvc insulated, pvc sheathed copper conductor flat submersible cable . 1134 supplying , flat flexible submersible cable with, copper conductor, pvc insulated, and pvc sheathed . 1135 3 core 1.5 sq mm 1136 3 core 2.5 sq mm 1137 3 core 4 sq mm 1138 3 core 6 sq mm 1139 3 core 10 sq mm 1140 3 core 16 sq mm 1141 3 core 25 sq mm 1142 3 core 35 sq mm 1143 copper conductor three core, xlpe / pvc insulated & unarmoured cable . 1144 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1145 3 core 1.5 sq mm 1146 3 core 2.5 sq mm 1147 3 core 4 sq mm 1148 3 core 6 sq mm 1149 3 core 10 sq mm 1150 3 core 16 sq mm 1151 3 core 25 sq mm 1152 3 core 35 sq mm 1153 3 core 50 sq mm 1154 3 core 70 sq mm 1155 3 core 95 sq mm 1156 copper conductor 3.5 core, xlpe / pvc insulated & armoured cable . 1157 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1158 3.5 core 1.5 sq mm 1159 3.5 core 2.5 sq mm 1160 3.5 core 4 sq mm 1161 3.5 core 6 sq mm 1162 3.5 core 10 sq mm 1163 3.5 core 16 sq mm 1164 3.5 core 25 sq mm 1165 3.5 core 35 sq mm 1166 3.5 core 50 sq mm 1167 3 .5 core 70 sq mm 1168 3.5 core 95 sq mm 1169 3.5 core 120 sq mm 1170 3 .5 core150sq mm 1171 3.5 core 185 sq mm 1172 3.5 core 240sq mm 1173 3.5 core 300 sq mm 1174 3.5 core 400 sq mm 1175 copper conductor 3.5 core xlpe / pvcunarmoured 1176 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1177 3.5core 25 sq mm 1178 3.5core 35 sq mm 1179 3.5 core 50 sq mm 1180 3.5 core 70 sq mm 1181 3.5 core 95 sq mm 1182 3.5 core 120 sq mm 1183 3.5 core150sq mm 1184 3.5 core 185 sq mm 1185 3.5 core 240sq mm 1186 3.5 core 300 sq mm 1187 3.5 core 400 sq mm 1188 copper conductor three core, xlpe / pvc insulated & armoured cable . 1189 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1190 3 core 1.5 sq mm 1191 3 core 2.5 sq mm 1192 3 core 4 sq mm 1193 3 core 6 sq mm 1194 3 core 10 sq mm 1195 3 core 16 sq mm 1196 3 core 25 sq mm 1197 3 core 35 sq mm 1198 3 core 50 sq mm 1199 3 core 70 sq mm 1200 3 core 95 sq mm 1201 3 core 120 sq mm 1202 3 core 150sq mm 1203 3core 185 sq mm 1204 3 core 240 sq mm 1205 3 core 300 sq mm 1206 3 core 400 sq mm 1207 foot valve ( m1063 ) 1208 foot valve 1209 supplying c.i. foot valve having single leather flap and gunmetal seating. valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. 1210 flanged type 1211 50 mm 1212 65 mm 1213 80 mm 1214 100 mm 1215 125 mm 1216 150 mm 1217 aircircuit breaker ( m1064 ) 1218 acbbreaking capacity 50ka thermal magnetic manual draw out type 3 pole 1219 630a 1220 800a 1221 1000a 1222 1250a 1223 1600a 1224 2000a 1225 starter ( m1065 ) 1226 d.o.l. starter with ss enclosure with 380 / 415 volt coil 1227 7.5 h.p. 1228 10 h.p. 1229 supplyingfully automatic star delta starter to operate induction motor working on415v, 3phase, 50 hz with no volt coil, over load element, on off push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser 1230 f.a.s.d starter 1231 10.0 h.p. 1232 15 h.p. 1233 20 h.p. 1234 25 h.p. 1235 35 h.p. 1236 40 hp 1237 50 hp 1238 75 h.p. 1239 100 h.p. 1240 125 h.p. 1241 150 h.p. 1242 250 h.p. 1243 servo controlled automatic voltage stabilizer ( m1066 ) 1244 providing, erecting servo controlled automatic voltage stabiliser suitable for out put voltage of 415 volt + / 1%, 3 ph, 50 hz, with copper wound transformer ( air / oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, auto / manual selector switch, raise / low push buttons etc. suitable capacity termination strips and bus bars for incoming and out going cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated over voltage / under voltage single phasing cut off contactor with electronic output sensing unit 1245 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 150 to 450 volt 1246 20 kva air cooled 1247 25 kva air cooled 1248 30 kva air cooled 1249 40 kva air cooled 1250 50 kva oil cooled 1251 60 kva oil cooled 1252 75 kva oil cooled 1253 100 kva oil cooled 1254 125 kva oil cooled 1255 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 280 to 460 volt 1256 15 kva air cooled 1257 20 kva air cooled 1258 25 kva air cooled 1259 30 kva air cooled 1260 40 kva air cooled 1261 50kva air cooled 1262 60 kva oil cooled 1263 75kva oil cooled 1264 100 kva oil cooled 1265 125 kva oil cooled 1266 150 kva oil cooled 1267 200kva oil cooled 1268 250kva oil cooled 1269 300 kva oil cooled 1270 400 kva oil cooled 1271 termination kit ( m1067 ) 1272 providing and errecting in door type termination kit, for 3.3kv / 6.6 kv / 11kv / 22kv / 33kv xlpe screened 3 core cable 1273 in door termination kit for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1274 25 50 mm2 1275 70 120 mm2 1276 150 185 mm2 1277 240 400 mm2 1278 out door termination kit for 3.3 ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1279 25 50 mm2 1280 70 120 mm2 1281 150 185 mm2 1282 240 400 mm2 1283 straight through joint for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1284 25 50 mm2 1285 70 120 mm2 1286 150 185 mm2 1287 240 300 mm2 1288 in door termination kit for 11kv ( e ) xlpe screened 3 core cable 1289 25 50 mm2 1290 70 120 mm2 1291 150 185 mm2 1292 240 400 mm2 1293 out door termination kit for 11kv ( e ) xlpe screened 3 core cable 1294 25 50 mm2 1295 70 120 mm2 1296 150 185 mm2 1297 240 400 mm2 1298 straight through joint for 11 kv ( e ) xlpe screened 3 core cable 1299 25 50 mm2 1300 70 120 mm2 1301 150 185 mm2 1302 240 300 mm2 1303 in door termination kit for 22kv ( e ) xlpe screened 3 core cable 1304 25 50 mm2 1305 70 120 mm2 1306 150 185 mm2 1307 240 400 mm2 1308 out door termination kit for 22kv ( e ) xlpe screened 3 core cable 1309 25 50 mm2 1310 70 120 mm2 1311 150 185 mm2 1312 240 400 mm2 1313 straight through joint for 22 kv ( e ) xlpe screened 3 core cable 1314 25 50 mm2 1315 70 95 mm2 1316 120 150 mm2 1317 185 240 mm2 1318 300 400 mm2 1319 in door termination kit for 33kv ( e ) xlpe screened 3 core cable 1320 25 50 mm2 1321 70 95 mm2 1322 120 185 mm2 1323 240 400 mm2 1324 out door termination kit for 33 kv ( e ) xlpe screened 3 core cable 1325 25 50 mm2 1326 70 95 mm2 1327 120 185 mm2 1328 240 400 mm2 1329 straight through joint for 33 kv ( e ) xlpe screened 3 core cable 1330 35 70 mm2 1331 95 150 mm2 1332 185 300 mm2 1333 400 mm2...
32223632 e quotation for rate of materials for schedule rate jharkhand under d w and s division, medininagar 2022 23. 1 polythene water storage tank of mark ( e.g sintex / sinter / himgiri / gangotietc ) with cover and locking system. ( m079 ) 2 gi pipe 50 mm dia ( tata or equivalent make ) ( m193 ) 3 jute ( m337 ) 4 g.m. ferrules ( m922 ) 5 ( i ) 8 mm dia wt. not less than 400 gms 6 ( ii ) 10 mm dia wt. not less than 400 gms 7 ( iii ) 15 mm dia wt. not less than 400 gms 8 ( iv ) 20 mm dia wt. not less than 600 gms 9 ( v ) 25 mm dia wt. not less than 900 gms 10 stop cocks ( m923 ) 11 ( i ) 15 mm brass stop cock wt. not less than 300 gms 12 ( ii ) 20 mm brass stop cock wt. not less than 400 gms 13 ( iii ) 25 mm brass stop cock wt. not less than 575 gms 14 ( iv ) 32 mm brass stop cock wt. not less than 850 gms 15 ( v ) 40 mm brass stop cock wt. not less than 1.15 kg 16 ( vi ) 50 mm brass stop cock wt. not less than 2.15 kg 17 ( vii ) 15 mm dia c.i. body brass working part stop cock. 18 ( viii ) 20 mm dia c.i. body brass working part stop cock. 19 ( ix ) 25 mm dia c.i. body brass working part stop cock. 20 g.m. full way valve ( m924 ) 21 ( i ) 15 mm dia wt. not less than 300 gms without wheel 22 ( ii ) 20 mm dia wt. not less than 400 gms without wheel 23 ( iii ) 25 mm dia wt. not less than 500 gms without wheel 24 ( iv ) 32 mm dia wt. not less than 700 gms without wheel 25 ( v ) 40 mm dia wt. not less than 1.0 kg without wheel 26 ( vi ) 50 mm dia wt. not less than 1.4 kg without wheel 27 ( vii ) 65 mm dia wt. not less than 1.8 kg without wheel 28 ( viii ) 80 mm dia wt. not less than 2.5 kg without wheel 29 g.m. non return valve verticle ( m925 ) 30 ( i ) 15 mm dia wt. not less than 150 gms 31 ( ii ) 20 mm dia wt. not less than 250 gms 32 ( iii ) 25 mm dia wt. not less than 375 gms 33 ( iv ) 32 mm dia wt. not less than 600 gms 34 ( v ) 40 mm dia wt. not less than 700 gms 35 ( vi ) 50 mm dia wt. not less than 1.0 kg 36 ( vii ) 65 mm dia wt. not less than 1.20 kg 37 ( viii ) 80 mm dia wt. not less than 1.50 kg 38 ( ix ) 100 mm dia wt. not less than 1.80 kg 39 g.m. non return valve horizontal ( m926 ) 40 ( i ) 15 mm dia wt. not less than 150 gms 41 ( ii ) 20 mm dia wt. not less than 250 gms 42 ( iii ) 25 mm dia wt. not less than 375 gms 43 ( iv ) 32 mm dia wt. not less than 600 gms 44 ( v ) 40 mm dia wt. not less than 700 gms 45 ( vi ) 50 mm dia wt. not less than 1.0 kg 46 ( vii ) 65 mm dia wt. not less than 1.20 kg 47 ( viii ) 80 mm dia wt. not less than 1.50 kg 48 ( ix ) 100 mm dia wt. not less than 1.80 kg 49 cocks ( m927 ) 50 ( i ) 15 mm dia g.m. bib cock wt. not less than 300 gms 51 ( ii ) 15 mm dia brass bib cock wt. not less than 400 gms 52 ( iii ) 15 mm dia c.i. bib cock wt. not less than 400 gms 53 ( iv ) 15 mm dia c.i. body brass working part spray painted bib cock wt. not less than 400 gms 54 ( v ) 15 mm dia c.i. brass pillar cock cock wt. not less than 400 gms 55 ( vi ) 15 mm c.i. plug cock ordinary 56 ( vii ) 15 mm c.i. push cock ordinary 57 chromium plated brass fittings ( m928 ) 58 ( i ) c.p. shower rose 100 mm dia 59 ( ii ) c.p. shower rose 125 mm dia 60 ( iii ) p.v.c. shower rose 150 mm dia 61 ( iv ) p.v.c shower rose 125 mm dia 62 connection pipe ( m929 ) 63 ( i ) 15 mm dia x 30 cm. long lead connection pipe with brass fittings. 64 ( ii ) 15 mm dia x 45 cm. long lead connection pipe with brass fittings. 65 ( iii ) 15 mm dia x 30 cm. long pvc connection pipe with brass fittings. 66 ( iv ) 15 mm dia x 45 cm. long pvc connection pipe withbrass fittings. 67 g.i. fittings ( conforming to i.s. 1879 ) isi marked ( m930 ) 68 [ a ] g.i. bend 69 ( i ) 15 mm 70 ( ii ) 20 mm 71 ( iii ) 25 mm 72 ( iv ) 32 mm 73 ( v ) 40 mm 74 ( vi ) 50 mm 75 ( vii ) 65 mm 76 ( viii ) 80 mm 77 ( ix ) 100 mm 78 ( x ) 125 mm 79 ( xi ) 150 mm 80 [ b ] elbow of the following sizes 81 ( i ) 15 mm 82 ( ii ) 20 mm 83 ( iii ) 25 mm 84 ( iv ) 32 mm 85 ( v ) 40 mm 86 ( vi ) 50 mm 87 ( vii ) 65 mm 88 ( viii ) 80 mm 89 ( ix ) 100 mm 90 ( x ) 125 mm 91 ( xi ) 150 mm 92 [ c ] tee plain of the following sizes 93 ( i ) 15 mm 94 ( ii ) 20 mm 95 ( iii ) 25 mm 96 ( iv ) 32 mm 97 ( v ) 40 mm 98 ( vi ) 50 mm 99 ( vii ) 65 mm 100 ( viii ) 80 mm 101 ( ix ) 100 mm 102 ( x ) 125 mm 103 ( xi ) 150 mm 104 [ d ] reducing tee plain of the following sizes ( taking larger dimension ) 105 ( i ) 20 mm 106 ( ii ) 25 mm 107 ( iii ) 32 mm 108 ( iv ) 40 mm 109 ( v ) 50 mm 110 ( vi ) 65 mm 111 ( vii ) 80 mm 112 ( viii ) 100 mm 113 ( ix ) 125 mm 114 ( x ) 150 mm 115 [ e ] socket plain of the following size ( taking larger dimension ) 116 ( i ) 15 mm 117 ( ii ) 20 mm 118 ( iii ) 25 mm 119 ( v ) 40 mm 120 ( vi ) 50 mm 121 ( vii ) 65 mm 122 ( viii ) 80 mm 123 ( ix ) 100 mm 124 ( x ) 125 mm 125 ( xi ) 150 mm 126 [ f ] reducing socket plain of the following sizes ( taking larger dimension ) 127 ( i ) 20 mm 128 ( ii ) 25 mm 129 ( iii ) 32 mm 130 ( iv ) 40 mm 131 ( v ) 50 mm 132 ( vi ) 65 mm 133 ( vii ) 80 mm 134 ( viii ) 100 mm 135 ( ix ) 125 mm 136 ( x ) 150 mm 137 [ g ] union socket of the following sizes 138 ( i ) 15 mm 139 ( ii ) 20 mm 140 ( iii ) 25 mm 141 ( iv ) 32 mm 142 ( v ) 40 mm 143 ( vi ) 50 mm 144 ( vii ) 65 mm 145 ( viii ) 80 mm 146 ( ix ) 100 mm 147 ( x ) 125 mm 148 ( xi ) 150 mm 149 [ h ] plugs of the following sizes 150 ( i ) 15 mm 151 ( ii ) 20 mm 152 ( iii ) 25 mm 153 ( iv ) 32 mm 154 ( v ) 40 mm 155 ( vi ) 50 mm 156 ( vii ) 65 mm 157 ( viii ) 80 mm 158 ( ix ) 100 mm 159 ( x ) 125 mm 160 ( xi ) 150 mm 161 [ i ] jam nuts of the following sizes 162 ( i ) 15 mm 163 ( ii ) 20 mm 164 ( iii ) 25 mm 165 ( iv ) 32 mm 166 ( v ) 40 mm 167 ( vi ) 50 mm 168 ( vii ) 65 mm 169 ( viii ) 80 mm 170 ( ix ) 100 mm 171 ( x ) 125 mm 172 ( xi ) 150 mm 173 [ j ] g.i. nipple of the following sizes 174 ( i ) 15 mm dia x 100 mm long 175 ( ii ) 20 mm dia x 100 mm long 176 ( iii ) 25 mm dia x 100 mm long 177 ( iv ) 32mm dia x 100 mm long 178 ( v ) 40 mm dia x 100 mm long 179 ( vi ) 50 mm dia x 100 mm long 180 ( vii ) 65 mm dia x 100 mm long 181 ( viii ) 80 mm dia x 100 mm long 182 ( ix ) 100 mm dia x 100 mm long 183 [ k ] g.i. pipes midium ( tata mark ) or equivalent as per is 1239 ( part 01 ) / 2004 isi marked / medium quality 184 ( i ) 15 mm dia 185 ( ii ) 20 mm dia 186 ( iii ) 25 mm dia 187 ( iv ) 32 mm dia 188 ( v ) 40 mm dia 189 ( vii ) 65 mm dia 190 mirrors ( m931 ) 191 ( a ) mirror of 6 mm thick plain glass 600 mm x 450 mm beveled edge mirror includingc.p. brass revolving fittings 3 mm plywood boardand c.p. hinges etc.to fix the mirror 192 ( b ) do 450 mm x 300 mm do 193 ( a ) glass shelf 600 mm x 125 mm with c.p. brass rail ( m932 ) 194 ( b ) do 450 mm x 125 mm do 195 ( a ) c.p. brass towel rail 20 mm x 600 mm with bracket all complete ( m933 ) 196 ( b ) anodized aluminum 20 mm x 600 mm towel rail complete with brackets 197 c.p. brass soap dish medium quality with screw andhinges etc. ( m934 ) 198 c.p. liquid soap solution holder ( m935 ) 199 vitreous white glazed indian water closet of hindustan / parry ware / cera / naycer or anyotherequivalent make ( m936 ) 200 ( a ) 580 mm long 201 ( b ) 510 mm long 202 ( c ) 450 mm long 203 ( d ) 510 mm long white glazed fiber i.w.c 204 pair of vetreous white glazed foot rest of hindustan / parryware / cera / naycer or any other equivalent make ( m937 ) 205 15 liters capacity pull and let go high level c.i. cistern complete with ball cock and a pair of bracket ( m938 ) 206 ( a ) 12.5 liters lowdown c.i. cistern ( m939 ) 207 ( b ) 10.0 liters capacity p.v.c. low design cistern 208 ( a ) white glazed vitreous e.w.c with p trap orany other equivalent make. ( m940 ) 209 ( b ) e.w.c with s trap 400 mm high of hindustan / parry ware / cera / naycear or any other equivalent make 210 ( c ) black / white plastic seat for e.w.c do as above. 211 ( a ) white glazed vitreous earthen were urinal flat back of hindustan / parryware / cera / naycer or any other equivalent make 600 mm x 350 mm size. ( m941 ) 212 ( b ) do squatting small 450 mm x 350 mm 213 ( c ) do squatting large 600 mm x 350 mm 214 ( d ) white glazed vitreous earthen ware urinal standing corner size 600 mm x 350 mm hindustan / parryware / cera / naycer or any other equivalent make 215 ( e ) partition plate for urinal 25 x 13 size 216 ( f ) 5 liters c.i. automatic cistern with all p.v.c fittings 217 white glazed vitreous wash hand basin 550 mm x 400mm size of hindustan / parryware / cera / naycer or any otherequivalent make. ( m942 ) 218 white glazed vitreous earthen ware kitchensinks of hindustan / parryware / cera / nayceror any other equivalent make ( m943 ) 219 ( a ) kitchen sink 600 mm x 450 mm x 200 mm ( 24 x 18 x 8 ) 220 ( b ) kitchen sink 600 mm x 450 mm x 250 mm ( 24 x 18 x 10 ) 221 ( c ) lab sink 450 mm x 300 mm x 150 mm ( 18 x 12 x 6 ) 222 ( d ) lab sink 300 mm x 250 mm x 150 mm ( 12 x 10 x 6 ) 223 drain board. ( m944 ) 224 ( a ) 600 mm x 450 mm ( 24 x 18 ) 225 ( b ) 525 mm x 450 mm ( 21 x 18 ) 226 h.c.i. pipes ( m945 ) 227 ( a ) 50 mm dia single socket 6 0 ( with ear weight 13 kg ) 228 ( b ) 80 mm dia single socket 6 0 ( with ear weight 18 kg ) 229 ( c ) 100 mm dia single socket 6 0 ( with ear weight 23 kg ) 230 ( d ) 150 mm dia single socket 6 0 ( with ear weight 30 kg ) 231 ( e ) 50 mm dia double socket 6 0 ( with ear weight 14 kg ) 232 ( f ) 80 mm dia double socket 6 0 ( with ear weight 19 kg ) 233 ( g ) 100 mm dia double socket 6 0 ( with ear weight 25 kg ) 234 ( h ) 150 mm dia double socket 6 0 ( with ear weight 13 kg ) 235 ( i ) 50 mm dia single socket 3 0 ( with ear weight 7.25 kg ) 236 ( j ) 80 mm dia single socket 3 0 ( with ear weight 10.5 kg ) 237 ( k ) 100 mm dia single socket 3 0 ( with ear weight 13.75 kg ) 238 ( l ) 150 mm dia single socket 3 0 with ear 239 ( m ) 50 mm dia single socket 2 0 ( with ear weight 5.35 kg ) 240 ( n ) 80 mm dia single socket2 0 ( with ear weight 8.00 kg ) 241 ( o ) 100 mm dia single socket 2 0 ( with ear weight 10.10 kg ) 242 ( p ) 150 mm dia single socket 2 0 with ear 243 ( q ) 50 mm dia single socket 1 0 ( with ear weight 3.4 kg ) 244 ( r ) 80 mm dia single socket 1 0 ( with ear weight 5.50 kg ) 245 ( s ) 100 mm dia single socket 1 0 ( with ear weight 7.60 kg ) 246 ( t ) 150 mm dia single socket 247 h.c.i. fittings. ( m946 ) 248 ( i ) plain bend of following size 249 ( a ) 50 mm dia ( weight without ear and socket 2.75 kg ) 250 ( b ) 80 mm dia ( weight without ear and socket 3.5 kg ) 251 ( c ) 100 mm dia ( weight without ear and socket 4.5 kg ) 252 ( d ) 150 mm dia ( weight without ear and socket 4.5 kg ) 253 ( ii ) bend with door with following size 254 ( a ) 50 mm dia ( wight without ear and socket 2.75 kg ) 255 ( b ) 80 mm dia ( wight without ear and socket 4.00 kg ) 256 ( c ) 100 mm dia do 5.5 kg 257 ( d ) 150 mm dia do 258 ( iii ) single junction with door of followings sizes. 259 ( a ) 50 mm dia ( weight without ear and socket 3.75 kg ) 260 ( b ) 80 mm dia ( weight without ear and socket 6.50 kg ) 261 ( c ) 100 mm dia do 9.50 kg 262 ( d ) 150 mm dia do 263 ( iv ) double junction with door of following sizes. 264 ( a ) 50 mm dia do 4.5 kg 265 ( b ) 80 mm dia do 7.00 kg 266 ( c ) 100 mm dia do 13.00 kg 267 ( d ) 150 mm dia do 268 ( v ) heel rest bend of following sizes 269 ( a ) 50 mm dia 270 ( b ) 80 mm dia 271 ( c ) 100 mm dia 272 ( d ) 150 mm dia 273 ( vi ) cowel of following sizes 274 ( a ) 50 mm dia ( weight without ear and socket 2.25 kg ) 275 ( b ) 80 mm dia ( weight without ear and socket 3.25 kg ) 276 ( c ) 100 mm dia ( weight without ear and socket 3.25 kg ) 277 ( d ) 150 mm dia do 278 ( vii ) 100 mm dia p trap ( wt without ear and socket ) 8.5 kg 279 ( viii ) 100 mm dia p trap ( wt without ear and socket ) 8.8 kg 280 ( ix ) 100 mm x 80 mm floor trap ( weight without ear and socket ) 4.00 kg 281 ( x ) pass over 50 mm x 150 mm for 50 mm projection 282 ( xi ) do 100 mm x 150 mm for 100 mm projection 283 ( xii ) inverted junction single 100 mm x 50 ( weight without ear and socket ) 9.0 kg 284 ( xiii ) inverted junction double 100 mm x 50 mm x 50 mm ( weight without ear and socket ) 12.0 kg 285 ( xiv ) h.c.i. offset 80 mm projection of the following size 286 ( a ) 50 mm dia ( weight without ear and socket ) 2.75 kg 287 ( b ) 80 mm dia do 3.50 kg 288 ( c ) 100 mm dia do 5.00 kg 289 ( d ) 150 mm dia do 290 ( xv ) h.c.i. socket of following sizes 291 ( a ) 50 mm dia ( weight without ear ) 1.50 kg 292 ( b ) 80 mm dia ( weight without ear ) 3.00 kg 293 ( c ) 100 mm dia ( weight without ear ) 4.50 kg 294 ( d ) 150 mm dia ( weight without ear ) do 295 c.i. cover with frame for manhole and inspection chamber. ( m947 ) 296 ( a ) 600 mm x 450 mm size ( wt. 39 kg ) 297 ( b ) 600 mm x 450 mm size ( wt. 25 kg ) 298 ( c ) 500 mm x 450 mm size ( wt. 25 kg ) 299 c.i. bracket pair for w.h.b. ( m948 ) 300 ( a ) 550 mm x 400 mm size ( 22 x 16 ) 301 ( b ) do for 12.5 liter cistern 302 ( c ) do for 600 mm x 450 mm ( 24 x 18 ) sink 303 ( d ) 40 mm x 60 mm ms plate bracket for sink as above 304 ( a ) 32 mm ( 1 1 / 4 ) c.p. brass waste for w.h.b ( m949 ) 305 ( b ) 40 mm ( 1 1 / 2 ) c.p. brass waste for w.h.b for sink 306 ( c ) 32 mm ( 1 1 / 4 ) c.p. waste of white metal 307 ( d ) 40 mm ( 1 1 / 2 ) c.p. waste of white metal 308 ( a ) 32 mm ( 1 1 / 4 ) p.v.c. waste pipe 750 mm long ( 26 long ) withbrass union for w h b ( m950 ) 309 ( b ) 40 mm ( 1 1 / 2 ) p.v.c. waste pipe 750 mm long ( 26 long ) with brass union for w h b 310 32 mm ( 1 1 / 4 ) p.v.c. telescopic flush pipe with brass union for high level cistern ( m951 ) 311 rubber inserttion 3 mm ( 1 / 8 ) thick ( m952 ) 312 pig lead ( m953 ) 313 yarn ( m954 ) 314 rubber gasket for c.i pipe of good quality ( m955 ) 315 ( a ) 80 mm 316 ( b ) 100 mm 317 ( c ) 125 mm 318 ( d ) 150 mm 319 ( e ) 200 mm 320 ( f ) 250 mm 321 ( g ) 300 mm 322 ( h ) 350 mm 323 ( i ) 400 mm 324 ( j ) 450 mm 325 ( k ) 500 mm 326 ( l ) 600 mm 327 ( m ) 700 mm 328 ( n ) 750 mm 329 ( o ) 800 mm 330 ( p ) 900 mm 331 ( q ) 1000 mm 332 ( r ) 1200 mm 333 cotton waste ( m956 ) 334 asbestos suta ( gland packing ) ( m957 ) 335 solvent cement ( m958 ) 336 hydrocloric acid ( sepecific gravity 1.20 ) ( m959 ) 337 cp & pvc fitting ( m960 ) 338 ( i ) 32 mm dia c.p. waste 339 ( ii ) 32 mm dia pv c waste pipe 750 mm long with coupling 340 ( iii ) 40 mm dia c.p. waste 341 ( iv 40 mm dia pvc waste pipe 750 mm long with coupling 342 ( v 100 mm dia steel jali 343 ( vi ) 15 mm dia c.p. nipple with coupling ( short pieces ) 344 ( vii ) 50 mm dia pvc pipe with coupling 345 special type of c.p. bath room fittings for v.i.p.buildings ( jal, jaquar, marc or equivalent mark ) ( m961 ) 346 ( i ) pillar cock ( isi ) 347 ( ii ) pillar cock ( long neck ) 348 ( iii ) bib cock ( isi ) 349 ( iv ) bib cock ( long thread ) 350 ( v ) angular stop cock 351 ( vi ) angular stop cock ( long thread ) 352 ( vii ) concealed stop cock reduce ( isi ) 353 ( viii ) concealed stop cock heavy duty extra adjustable wall flange 354 ( ix ) long body bib cock 355 ( x ) swan neck tap with left hand operating knob 356 ( xi ) central hole basin mixer ( best quality ) 357 ( xii ) wall mixer with telephonic shower arrangement 358 ( xiii ) wall mixer with provision for over head shower with elbow coupling and well flange 359 ( xiv ) wall mixer 3 in 1 system with provision for over head shower with elbow coupling and wall flange 360 ( xv ) sink mixer with swinging casted spout 361 ( xvi ) sink cock with swinging casted spout 362 ( xvii ) 4 way diverter for concealed fittings 363 ( xviii ) pressure adjustable shower with revolving joint 364 ( xix ) telephone shower with flexible pipe 365 ( xx ) flush cock with wall flange ( 25 mm ) 366 ( xxi ) towel rail 24 367 ( xxii ) towel ring 368 ( xxiii ) soap dish 369 ( xxiv ) tumbler holder 370 ( xxv ) toilet paper holder 371 ( xxvi ) glass shelf 22 372 ( xxvii ) corner glass shelf with bracket 373 ( xxviii ) flush valve complete with 32 mm size controlcock & flange 374 c.i special & pvc pipes ( m962 ) 375 1. c.i double shocketted fittings bend such as bend, tee, taper, 376 ( a ) 80 200 mm 377 ( b ) 250 700 mm 378 ( c ) 700 1000 mm 379 2. c.i double flange fittings such as tee, taper, tailpiece, bend etc 380 ( a ) 80 200 mm 381 ( b ) 250 700 mm 382 ( c ) 700 1000 mm 383 spare parts of hand pump 384 basic rate of upvc pipe 125mm dia conforming to i.s.i. latest revision is 12818 / 2016 cml no. 5543459 ( m1024 ) 385 rcc esr ( m1030 ) 386 designing ( aesthetically ) , and constructing rcc elevated service reservoirs of following capacity with rcc staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for esr having capacity upto 500 cum and not more than 6m c / c for esr having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the in side and out side face of the container and also plaster with plastic paint in all columns and bracingsincluding refilling disposing off the surplus stuff with in a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as m.s. ladder out side, stainless steel lader in contenor, c.i. manhole frame and covers, water level indicators, lightening conductor, g.i. pipe railing around walk way and top slab, providing stair case from ground level to roof level, m.s. grill gate of 2m height with locking arrangement of approved design, b.b. masonry chambers for all valves, ventilating shafts, providing and applying three coats of acrylie emulsion with silicon edditives paint to the structure incluingroof slab, epoxy painting to internal surface and anti termite treatment for under ground part soft he structure and giving satisfactory water tightness test as per i.s. code. the job to include painting then ame of the scheme and other details on thereservoir as per the directions of engineer in charge. 387 notes 388 the design of the structure be in accordance with relevant i.s. specification ( i.s. 3370 1965 or revised. ) 389 the design shall satisfy the stipulations as per i.s. 1893 1984 and i.s.13920 / 1993 for seismic force and i.s. 11682 / 1985 for r.c.c. staging of over head tanks. 390 for design having more than 6 columns, suitable bracing is obligatory. 391 plain round mild steel bars grade i conforming to i.s.432 part i orhigh yield strength deformed bars conforming to i.s. 1786 or i.s. 1139 shall beused, grade i imildsteel bars will not be allowed 392 irrespective of the type of foundation proposed in the design, one set of bracing be provided at the ground level. 393 these rates include providing m.s. ladder for e.s.r.s upto 2 lakh litres capacity and providing spiral stair case for e.s.r. above 2 lakh litres capacity. 394 staging shall have to bede signed with stresses of m 200 concrete for esr. however all rcc construction should be donein m 250. structures in contact with water shall be designed & casted in m 300 395 these rates are including the cost of up lift pressure if any and entire dewatering during execution. incase of water logging are a where water is struck at shallow depth, extra provision of dewatering shall be made as per site condition. 396 all conditions given in the member secretarys circular no. mjp / ts i / 350 / 1668 dt. 2 8 97 and mjp / s i / 350 / 2127 dt. 13 7 99 shall be strictly followed and additional cost, if any, due to these conditions is included in the rates mentioned below. 397 75 % part rate shall be payable for reinforcement concrete and plastering items of containers of e.s.r. till satisfactory hydraulic testing for water tightness is given; and till that work shall be treated as incomplete. 398 the rates indicated in the table are excluding the cost of pipes, specials and valves required for inlet, outlet, washout, overflow and bypass arrangement. the scope of work, however, includes cost of erecting, laying and jointing of pipe and valves including cost of jointing materials upto 5 m beyond outer face of outer most column ( cost of pipe, specials and valves is taken as 10% of the cost of esr as per table ) . 399 for esr upto 500 cum capacity c.i. double flanged pipes upto 300 mm dia shall be provided and c.i. specials shall be used. for esr above 500 cum capacity c.i. / m.s. pipe assembly with minimum 8 mm thickness upto 500 mm dia and minimum 10 mm thickness above 500 mm dia can be used with proper anti corrosive epoxy treatment from in side and out side. 400 below mentioned rates are for foundation swith individual footing with bearing capacity of 20 tonnes per square metre. for raft foundations, these rates shall be increased by 7.5% where safe bearing capacity ( sbc ) is 5 mt per sqm and by 5 % where sbc is more than 5mt / sqm and upto 10 mt / sqm. this % of5 % or 7. 5 % is applicable for estimation of amount of lumpsum item of esr. for extra item due to change from individual foundation to raft, actual increase in concrete and steel be paid as per relevant dsr item. 401 the rate shall be increased by 30 % for bearing piles upto depth of 10 m and for further increased in depth by 5 m each, it shall be increased by another 10%. these rates are applicable where raft is not feasible. for pile foundations sulphate resistant cement shall only beused. single pile for the column is not permitted, group of piles shall be designed with pile cap for each column of esr. 402 the rates are applicable for staging height of 12 m. these rates shall be increased or decreased for per metre variation in this staging height as below : 403 12 to 16 m staging 2% per metre 404 16 to 20 m staging 3% per metre 405 20 m and above 4% per metre 406 for 17 m staging height, percentage calculation will be like below : 407 12 to 16 m 4 x 2 = 8% 408 16 & 17 m 1 x 3% = 3% total = 11% 409 for 21 m staging height, percentage calculation will be like below : 410 12 to 16 m 4 x 2 = 8% 411 16 to 20 m 4 x 3% = 12% 412 20& 21 m 1 x 4% = 4% total = 24% 413 following rates are for seismic zone iii. for zone iv, these rates shall be increased by 5% and for zone ii, these rates shall be decreased by 5%. concerned executive engineer shall confirm the seismic zone for the scheme from seismic zone splan before estimation and adopt appropriate rates as per actual seismic zones. ( seismic maps attached in this csr ) . 414 notes 415 conditions from sr.no.1 to 10 shall form a part and parcel of the tender and must be included in the draft tender papers for works of r.c.c. e.s.r. 416 conditions from sr.no.11 to 16 are for estimation purpose only and shall not appear in the tender. 417 rates for rcc esrs 418 upto 25, 000 litres 419 cost of 25, 000 litres capacity 420 add for capacity above 25, 000 upto 50, 000 litres 421 cost of 50, 000 litres capacity 422 add for capacity above 50, 000 upto 75, 000 litres 423 cost of 75, 000 litres capacity 424 add for capacity above 75, 000 upto 1, 00, 000 litres 425 cost of 1, 00, 000 litres capacity 426 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 427 cost of 1, 50, 000 litres capacity 428 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 429 cost of 2, 00, 000 litres capacity 430 add for capacity above 2, 00, 000 upto 2, 50, 000 litres 431 cost of 2, 50, 000 litres capacity 432 add for capacity above 2, 50, 000 upto 3, 00, 000 litres 433 cost of 3, 00, 000 litres capacity 434 add for capacity above 3, 00, 000 upto 4, 00, 000 litres 435 cost of 4, 00, 000 litres capacity 436 add for capacity above 4, 00, 000 upto 5, 00, 000 litres 437 cost of 5, 00, 000 litres capacity 438 add for capacity above 5, 00, 000 upto 7, 50, 000 litres 439 cost of 7, 50, 000 litres capacity 440 add for capacity above 7, 50, 000 upto 10, 00, 000 litres 441 cost of 10, 00, 000 litres capacity 442 add for capacity above 10, 00, 000 upto 15, 00, 000 litres 443 cost of 15, 00, 000 litres capacity 444 add for capacity above 15, 00, 000 upto 20, 00, 000 litres 445 cost of 20, 00, 000 litres capacity 446 rcc gsr and sump ( m1031 ) 447 designing ( aesthetically ) , and constructing rcc ground service reservoirs / rcc sumps in m 300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top rcc roof slab / or dome, 20 mm thick cement plaster with water proofing compound in cm 1:3 proportion. to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 m, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye pass arrangement consisting of c.i. / m.s. d / f. pipes, specials and valves of given diameters, providing and fixing accessories such as m.s. ladder inside and outside, c.i. manhole frame and cover, water top slab, b.b. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per is code and providing three coat of cement paints to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. 448 anti –termite treatment shall be given for under ground portion of the structure. 449 notes 450 the design shall be in accordance with various relevant i.s. specification ( i.s.456 / 2000, i.s.875 1987, i.s.3370 1965 or revised. ) 451 only m.s. bars grade i conforming to i.s. 432 part i or high yield strength deformed bars conforming to i.s. 1786 or i.s.1139 shall be used.grade ii m.s. bars shall not be used. 452 entire structure shall be in m 300 only. 453 the scope of pipe assembly work shall be upto 5 metre beyond out side face of the wall, cost of pipes valves and specials is not included in the rate but labour cost for laying and jointing is included. 454 the g.s.r. / sump above 15 lakh litres capacity shall be in two compartment. 455 the job includes designing the structure for up lift pressure and dewatering if required during entire execution and disposal of surplus excavated stuff within lead of 50 metres as directed by engineer in charge. if up lifts considered in design, then these rates shall be increased by 7.5%. 456 g.s.r. outlets shall be with bell mouth of approved pattern in bottom slab and cost of designing bell mouth is included in the rate. sump well includes cost of suction pit required at bottom. 457 for pipe diameters upto 300mm only cipipes and ci specials shall be used. for pipe diameters above 300mm, m.s. pipes and specials minimum 10mm thick shall be used with proper anti corrosive epoxy treatment from inside and outside. 458 cost of pump house is not included in these rates. 459 above rates are applicable for seismic zones 2, 3 and 4. 460 75% part rate shall be payable for reinforcement, concrete and plastering items of all types of g.s.r. sand sump still satisfactory hydraulic testing for water tightness test is given and till that work shall be treated as incomplete. 461 10% shall be added for sump if over head pump house is proposed. 462 note: conditions from sr.no.1 to 11 shall form a part and parcel of tender and must be included in the draft tender papers for work of r.c.c .gsrs and sumps. 463 rates for rcc gsrs and sumps 464 upto 25, 000 litres 465 cost of 25, 000 litres capacity 466 add for capacity above 25, 000 upto 50, 000 litres 467 cost of 50, 000 litres capacity 468 add for capacity above 50, 000 upto 75, 000 litres 469 cost of 75, 000 litres capacity 470 add for capacity above 75, 000 upto 1, 00, 000 litres 471 cost of 1, 00, 000 litres capacity 472 add for capacity above 1, 00, 000 upto 1, 50, 000 litres 473 cost of 1, 50, 000 litres capacity 474 add for capacity above 1, 50, 000 upto 2, 00, 000 litres 475 cost of 2, 00, 000 litres capacity 476 add for capacity above 2, 00, 000 upto 3, 00, 000 litres 477 cost of 3, 00, 000 litres capacity 478 add for capacity above 3, 00, 000 upto 5, 00, 000 litres 479 cost of 5, 00, 000 litres capacity 480 add for capacity above 5, 00, 000 upto 10, 00, 000 litres 481 cost of 10, 00, 000 litres capacity 482 addforcapacityabove10, 00, 000upto15, 00, 000 litres 483 cost of 15, 00, 000 litres capacity 484 add for capacity above 15, 00, 000 litres 485 note: 10% shall be added over the cost of gsr for sump where over head pump house is proposed. 486 unconventionalwater treatment plant ( m1032 ) 487 designing ( aesthetically ) , providing and constructinghigh rate unconventionalwatertreatmentplant i.e. simplified water treatment plant consisting of civil works includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidinganti termitetreatmenttoentirestructurebelowgroundlevel, ceramic tiles for floring, acrylic emulsion with silicon additives paint from outside stainless steel railing, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow : includingnecessaryhydraulic testing, structuraltesting and trial for 3 months, etc. completeas directedbyengineer in charge ( turn key job ) works. 488 aeration fountain 489 inlet arrangements 490 mixing channel with ventury flume and flow measuring arrangement 491 inlet channel 492 flocculator conforming to i.s. 7208 1974 ( type c ) with detention period of 30 minutes 493 tube settlers designing, fabricating and constructing tube settlers with square or any other shaped tube like circular, cheveron, hexagonal etc .having proven performance 494 rapid sand gravity filters all valve shall be glandless. 495 filter house 496 chemical house 497 alum tanks 2nos. with mixing, carrying and dosing arrangements with piping. 498 100 kg chlorine cylender for capacity upto 5mld and chlorine tonner for capacity above 5 mld. 499 tcl solution tank with mixing, carrying and dosing arrangement with piping. 500 bypass arrangement 501 external and internal electrification 502 laboratory equipments 503 wash water tanks of capacity equal to12 minutes to wash specified number of filter beds at time at 600 lit / m2 / m under head of 12m at under drain. 504 wash water pumps with 100% standby 505 air blowers capable of delivering 600 lmp per square metre of free air of filter area at 0.4 kg / sqcm at the under drains ( 100 % standby ) .air blowers shall be adopted for wtp having capacity more than 3 mld only. below 3 mld capacity, air blowers shall not be adopted. 506 pure water sump of capacity equal to 1 hourpumping capacity. 507 pure water pump house over the sump / by the side of sump. 508 drainage arrangements 509 alum store 510 sanitary block with necessary water supply and drainage arrangements and internalwbm roads. 511 these rates are applicable for seismic zones 2, 3 and 4. 512 rates given below are inclusive of uplift pressure if any and dewatering during the entire work. 513 all rcc structures shall be constructed in m 250. structures in contact with water shall be in m 300. 514 unconventional treatment plants less than 1 mld capacity shall not be constructed. 515 all the structural steel works / fabrications are to be provided with application of hot dip zinc coating according to specification as per is 4759:1996 ( reafirmed 2006 ) . 516 note: conditions from sr. no. 1 to 28 shall form a part and parcel of the tender and must be included in draft tender papers for the work of unconventional treatment plants. 517 unconventional water treatment plant 518 fixed cost for 1 mld 519 add for capacity above 1 mld upto 2 mld 520 cost of 2 mld treatment plant 521 add for capacity above 2 mld upto 3 mld 522 cost of 3 mld treatment plant 523 conventionalwater treatment plant ( m1033 ) 524 designing ( aesthetically ) , providingconstructingandcommissioningconventionalwatertreatmentplantconsistingofallcivil, mechanicalandelectricalworks includingcostofprovidingandapplyingepoxypainttoinsidesurfaceofwaterretainingstructuresincontactwithchlorineandprovidingantitermitetreatmenttoentirestructurebelowgroundlevel, mechanicalandelectricalcomponentsofvarioussub worksasgivenbelow, includingnecessaryhydraulic testing, structuraltesting, equipmenttestingandtrialrunfora periodof3 months, etc. completeas directedbyengineer in charge ( turn key job ) . 525 aeration fountain plan are a not less than 0.625 square metre per mld 526 ventury flume with necessary devices, consisting of simple mechanical indicator. ( pedestal type gauge ) 527 flash mixer rapid mixing device, detention time 60 seconds to give velocity gradient 300 to 400 sec 1, vane mixer type conforming to i.s. 7090 of 1985. 528 flocculator – conforming to i.s.7208 1974 ( type c ) with detention period of 30 minutes. 529 clarifier horizontal flow circular tank, detention period 2 5 hours, overflow rate 30 cubic metre per square metre per day ( to be specified ) , weir loading not more than 300 cubic metre per metre per day, with mechanical sludge scraper conforming to i.s. no. 10313 1982. 530 rapid sand filter sand filter house filter designed for filteration rate of 5, 000 litres per square metre per hour, minimum 2 beds for plant upto 10 mld, for larger plants as specified, filters to be located in filter house with roof slab, pipe gallery and platform minimum 5.5 metre in width. 531 filtersand effective size 0.45 to 0.70mm, uniformity coefficient not more than 1.7, nor less than 1.3, depth of water over sand 0.75m, free board 50cm, gravel 0.45m in depth, sand and gravel conforming to i.s. 8491 ( i ) 77, back wash by air wash, stand ard appurtenances ( to be specified ) , rate of flow controller, filter gauge, sand expansion gauge, etc. 532 wash water tank capacity to be specified and suitable to supply water to wash 2 filter units at a time where the units are 4 or more. 533 wash water pumps capacity to fill water tank in 1 hour with 100% standby. 534 air blowers capable of delivering 600 lmp per square metre of free air, of filter area at 0.4kg / sqcm at the under drains ( 100% standby ) . 535 chemical house in two storeys 536 ground floor to accommodate 7 days alum requirement and sundry storage. 537 first floor to accommodate alum and lime tanks.etc. 538 solution tanks minimum 3 tanks ( one for preparation, second for dosing and third as standby ) , each tank capable of giving 8 hours maximum dose without interruption, minimum free board 0.30m, trays for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines, solution feed device ( constant head device, strength of solution upto 10% only ) conforming to i.s. 9222 part i 1979. 539 pure water sump and sump house. 540 capacity of sump – one hour of designed flow. 541 pump house pump house of required size over the sump or by the side. 542 store house suitable for alum storage of three months requirement in monsoon with 10% extra capacity for other sundry articles. 543 vacuum feed type chlorinators make tobe approved by mjp. 544 conforming to i.s. 10533 a part ii 1983 545 rate for withdrawal 546 temperature kg. of chlorine discharge degree c per day ( cylinders ) 547 45 67 tonnes 548 10 6.359.50 110 549 15 10.75 16.10130 550 20 14.50 21.24254 551 27&above18.70 28.12315 552 chlorinator equipment and container room to conform to i.s. 10553 part i 1983. 553 100% standby shall be provided. 554 by pass arrangements c.i. or m.s. pipes. 555 disposal of waste from wtp: safe disposal arrangement to near by nala including cost of pipe 556 for wtp of capacity 30 mld and more additional arrangement for backwash water recycle shall be provided, including sump, pupming machinary, rising main etc complete 557 drainage arrangements – rcc pipes up to plot boundary. 558 electrical installation – both internal and external including entire plant area. 559 laboratory equipment –as per requirement ( to be specified during tendering ) . 560 sanitary blocks – carpet area 15 square metre minimum upto 25 mld and 25 square metre above 25 mld. 561 administrative block and internal road to accommodate office room, chlorine room, laboratory room, panel board room, blower room etc. and wbm road to connect all units from main gate of plot. 562 rates given below are inclusive of up lift pressure if any and dewatering during entire work. 563 all pipes condutes channels with20%overloading 564 these rates are applicable for seismic zones 2, 3 and 4. 565 all rcc structures shall be constructed in m 300. 566 note: conditions from sr. no. 1 to 22 shall form a part and parcel of the tender and must be incorporated in draft tender papers of conventional treatment plants ( proposed ) . 567 conventional water treatment plant 568 above3 mld to upto 5 mld 569 cost of 5 mld treatment plant 570 add for capacity above 5mld upto 10 mld 571 cost of 10 mld treatment plant 572 add for capacity above 10 mld upto20 mld 573 cost of 20 mld treatment plant 574 add for capacity above 20 mld upto 50 mld 575 cost of 50 mld treatment plant 576 add for capacityabove 50 mld upto 100 mld 577 cost of 100 mld treatment plant 578 add for capacity above 100 mld 579 gpt / hygpt : drilling by rotary drill machine of size 300mm & 400mm dia with t.c. drill bit for tubewells in all kinds of soil including moorum, hard soil, soil mixed with pebbles, shingles, compacted soil, clay, soft and decomposed rock etc, up to 60 meters depth including reaming to facilitate smooth lowering of casing pipe etc. as per specification and direction of e / i ( basic rates ) ( m1034 ) 580 300 mm dia for gpt 581 400 mm dia for hygpt 582 hydt : cost of drilling 200 mm x 165 mm x 125 meter deep bore well in all kinds of soil and rock in rural area for installation of pump set with hydraulic dth rig machine, all complete including supplying all materials, tools, drilling rig, air compressor and equipments, as well as fuel, lubricants and cost of transportation of rig machine and other vehicles up to the site ( basic rates ) ( m1035 ) 583 from 0 50 meter 584 from 51 125 meter 585 dt :basic rates for 125 / 115 mm dia drilled tube well for drilling in all kinds of soil and rock for installation of hand pump with dth rig machine all complete including supplying all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125 / 115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and dirrection of engineer incharge ( basic rates ) ( m1037 ) 586 drillig upto 30 mtr depth below g. l. in rural area 587 drilling beyond 31 mtr upto 60 mtr below g. l. in rural area 588 trenchless ( m1038 ) 589 installation of product pipe by manual pipe jacking method including making of entry and exit pits all related civil works like excavation , shoring / strutting etc manual shielded excation , lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 590 from 900 mm to 1000 mm dia 591 in soft soil 592 in hard soil 593 in sandy soil 594 in stone soil 595 from 1000 mm to 1200 mm dia 596 in soft soil 597 in hard soil 598 in sandy soil 599 in stone soil 600 above 1200 mm to 1500 mm dia 601 in soft soil 602 in hard soil 603 in sandy soil 604 in stone soil 605 installation of product pipe by auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 606 upto 300 mm dia 607 in soft soil 608 in hard soil 609 in sandy soil 610 in stone soil 611 above300 mm to 450 mm dia 612 in soft soil 613 in hard soil 614 in sandy soil 615 in stone soil 616 above 450 mm to 600 mm dia 617 in soft soil 618 in hard soil 619 in sandy soil 620 in stone soil 621 above 600 mm to 900 mm dia 622 in soft soil 623 in hard soil 624 in sandy soil 625 in stone soil 626 installation of product pipe by guided auger boring methodincluding making of entry and exit pits all related civil works like excavation , shoring / strutting etc shielded excavation , through auger boring process lowering of pipe segments in the jacking pit laying and jointing of product pipeline through jacking process from the jacking pit and restoration of site after project completion as per the instruction of the engineering in charge all complete exept the cost of the pipe average cover of 1.5 depth below gi ( upto 100 meter installation length ) 627 upto 300 mm dia 628 in soft soil 629 in hard soil 630 in sandy soil 631 in stone soil 632 above300 mm to 450 mm dia 633 in soft soil 634 in hard soil 635 in sandy soil 636 in stone soil 637 above 450 mm to 600 mm dia 638 in soft soil 639 in hard soil 640 in sandy soil 641 in stone soil 642 above 600 mm to 900 mm dia 643 in soft soil 644 in hard soil 645 in sandy soil 646 in stone soil 647 providing and supplying isi mark ci / d / f reflux valves ( non return valves ) of following dia inspection charges unloading from railway wagon , loading into truck transportation upto department stores / site unloading stacking etc. complete reflux valve as per is 5312 part i ( 1984 ) ( m1039 ) 648 without byepass arrangement pn 1 649 50 mm 650 65 mm 651 80 mm 652 100 mm 653 125 mm 654 150 mm 655 200 mm 656 250 mm 657 300 mm 658 350 mm 659 400 mm 660 450 mm 661 500 mm 662 600 mm 663 700 mm 664 750 mm 665 800 mm 666 900 mm 667 1000 mm 668 1100 mm 669 1200 mm 670 with byepass arrangement pn 1 671 50 mm 672 65 mm 673 80 mm 674 100 mm 675 125 mm 676 150 mm 677 200 mm 678 250 mm 679 300 mm 680 350 mm 681 400 mm 682 450 mm 683 500 mm 684 600 mm 685 700 mm 686 750 mm 687 800 mm 688 900 mm 689 1000 mm 690 1100 mm 691 1200 mm 692 without byepass arrangement pn 1.6 693 50 mm 694 65 mm 695 80 mm 696 100 mm 697 125 mm 698 150 mm 699 200 mm 700 250 mm 701 300 mm 702 350 mm 703 400 mm 704 450 mm 705 500 mm 706 600 mm 707 with byepass arrangement pn 1.6 708 50 mm 709 65 mm 710 80 mm 711 100 mm 712 125 mm 713 150 mm 714 200 mm 715 250 mm 716 300 mm 717 350 mm 718 400 mm 719 450 mm 720 500 mm 721 600 mm 722 providing double flange sluice valve ( size 50 mm to 1200 mm ) confirming for is 2906 / 14846 including worn gear arrangements as per test pressure stailess steel spindle , caps transportation etc. all complete . 723 with byepass arrangement pn 1 724 50 mm 725 65 mm 726 80 mm 727 100 mm 728 125 mm 729 150 mm 730 200 mm 731 250 mm 732 300 mm 733 350 mm 734 400 mm 735 450 mm 736 500 mm 737 600 mm 738 700mm 739 750 mm 740 800 mm 741 900 mm 742 1000 mm 743 1100 mm 744 1200mm 745 without byepass arrangement pn 1 746 50 mm 747 65 mm 748 80 mm 749 100 mm 750 125 mm 751 150 mm 752 200 mm 753 250 mm 754 300 mm 755 350 mm 756 400 mm 757 450 mm 758 500 mm 759 600 mm 760 700mm 761 750 mm 762 800 mm 763 900 mm 764 1000 mm 765 1100 mm 766 1200mm 767 providing double flange sluice valve confirming for is 2906 / 14846 including worn gearas per test pressure stailess steel spindle , caps transportation etc. all complete for rateincluding all taxes . . 768 without byepass arrangement pn 1.6 769 50 mm 770 65 mm 771 80 mm 772 100 mm 773 125 mm 774 150 mm 775 200 mm 776 250 mm 777 300 mm 778 350 mm 779 400 mm 780 450 mm 781 500 mm 782 600 mm 783 700mm 784 750 mm 785 800 mm 786 900 mm 787 1000 mm 788 1100 mm 789 1200mm 790 with byepass arrangement pn 1.6 791 50 mm 792 65 mm 793 80 mm 794 100 mm 795 125 mm 796 150 mm 797 200 mm 798 250 mm 799 300 mm 800 350 mm 801 400 mm 802 450 mm 803 500 mm 804 600 mm 805 design and supply of v wire screen laterals suitable for infiltration galleryas per site condition and detail provided end connection suitable flange excluding taxes and transportation . ( m1040 ) 806 dia 06 inch ( 150 mm ) 807 id 153 mm od 167 mm 808 screen thickness 07 mm 809 slot 1.00 mm 810 moc lowcarbon galvenised steel 811 length 5 mtr. 812 dia 08 inch ( 200 mm ) 813 id 205 mm od 221mm 814 screen thickness 08 mm 815 slot 1.00 mm 816 moc lowcarbon galvenised steel 817 length 5 mtr. 818 dia 10 inch ( 250 mm ) 819 id 256 mm od 276mm 820 screen thickness 10 mm 821 slot 1.00 mm 822 moc lowcarbon galvenised steel 823 length 5 mtr. 824 dia 12 inch ( 300 mm ) 825 id 306 mm od 326 mm 826 screen thickness 10 mm 827 slot 1.00 mm 828 moc lowcarbon galvenised steel 829 length 5 mtr. 830 dia 14 inch ( 350 mm ) 831 id 338 mm od 363 mm 832 screen thickness 12.5 mm 833 slot 1.00 mm 834 moc lowcarbon galvenised steel 835 length 5 mtr. 836 supplying all materials, labours, equipments for lowering 125mm dia blue upvc casing pipe as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site ( basic rate ) . ( m1041 ) 837 supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per dirction e / i ( basic rate ) . ( m1042 ) 838 supplying labour cement and calcium chloride or bentonite solution and equipments for grouting the casing pipe after lowering in the bore including carriage of materials to work site etc. all complete as per specification & direction of e / i ( basic rate ) . ( m1043 ) 839 supplying labour and equipments including 125mm dia g.i. cap and fitting and fixing over the casing pipe of tube well properly and taking it out as per direction e / i ( the cap will be the property of department ) ( basic rate ) . ( m1044 ) 840 supplying all materials, labours, equipments for constructing p.c.c. ( 1:2:4 ) circular platform around drilled tube well including 12mm thick cement plaster ( 1:4 ) with neat cement punning over exposed surface as per unicef design, etc. all complete including carriage of materials ( basic rate ) . ( m1045 ) 841 supplying all materials, labours and equipments for constructing p.c.c. ( 1:2:4 ) drain as per unicef design etc. all complete including carriage of materials ( basic rate ) . ( m1046 ) 842 supplying extra deep well hand pump complete sets with cylinder assembly & connecting rod ( 12 pcs ) as per is : 15500 part 2 / 2004 ( basic rate ) . ( m1047 ) 843 supply of 200mm dia x 3.00m long upvc casing pipe conferming to is : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1048 ) 844 supply of 200mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1049 ) 845 supply of 125mm dia ribbed screen pipe conferming tois : 12818: 2016 ( cml no. 5543459 ) latest revision including carrigae ( basic rate ) . ( m1050 ) 846 supplying all tools, equipments and labour and lowering 32 mm dia medium quality g.i. pipe in drilled tube well in 3 mtrs. length all complete as per dirction e / i including carriage of materials ( basic rate ) . ( m1051 ) 847 supplying all tools, labour for fitting and fixing deep well cylinder with necessary connecting rod complete job as per specification & direction of e / i including carriage of materials ( basic rate ) . ( m1052 ) 848 supplying all materials, labours and fixing india mark ii hand pump with all accessories all complete job as per direction of e / i including carriage of materials ( basic rate ) . ( m1053 ) 849 design, supply, installation testing & commissioning of packaged water treatment plants ( unconventional type ) of different capacity with ( 20 hours operation ) comprising of lamella clarifier, static mixture flocculation tank ( smet ) , multi grade filter ( mgf ) with best quality filter media, lime / coagulant / polymer dosing system hypo chloride dosing system, raw water feed pump / clear water transfer pump ( either or ) , sludge transfer cum recirculation pump, filter feed pump & back wash pump including all fitting like valve and other special fittings and electrical power supply to the different supplied units with mcb panel internal electrification with lighting arrangement with treatment plant site with provision of chemical storage and water testing boratoryfacility should be from a reputed manufacturer / authorized distribution / authorized dealer conforming to relevant is codes and certified by iso 9001 2008 & 14001, it also include cost of civil foundation, including clarified water tank internal connecting pipe line from raw water inlet to cwr and applying internal epoxy paint on the supply equipment all the prices are exclusive of gst, allied structure / items which are site specific such as external electrification, approach road, foot bridge, cofferdam, compound wall, scada and automation, cwr pumps etc are to be considered extra. ( m1054 ) 850 packaged lamella clarified type wtp with mgf capacity in mld. 851 0.2 852 0.3 853 0.4 854 0.5 855 0.6 856 pumps ( m1055 ) 857 supplying100 mm dia submersible pump sets confirming to is 8034 and motor confirming to is 9283. pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene / noryl impeller. motor suitable for working on 415v+10%, 3ph, 50 hz, a.c. supply with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. pump shall have suitable outlet as per manufacturers design. anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump. 858 submersible pump set 100 mm dia ( with polypropylene / noryl impeller ) up to 20 stages 859 1 h.p. 860 1.5hp 861 2 hp 862 2.5 hp 863 3.0 hp 864 4.0 hp 865 5.0 hp 866 supply rate should be increased by rs 200 / per stage for pump with more than 20 stages 867 submersible pump 150 mm dia ( with bronze impeller ) up to 8 stages 868 1.5 hp 869 2.0 hp 870 3.0 hp 871 4.0 hp 872 5.0 hp 873 6.0 hp 874 7.5 hp 875 supply rate should be increased by rs 600 / per stage for pump with more than 8 stages 876 submersible pump 150 mm dia ( with bronze impeller ) up to 12 stages 877 8.0 hp 878 9.0 hp 879 10.0 hp 880 11.0 hp 881 12.5 hp 882 15.0 hp 883 supply rate should be increased by rs 600 / per stage for pump with more than 12 stages 884 submersible pump 150 mm dia ( with bronze impeller ) up to 20 stages 885 17.5 hp 886 20.0 hp 887 25 hp 888 1 ) supply rate should be increased by rs 600 / per stage for pump with more than 20 stages for bore well only. 889 for other use 200 mm dia pump shall be preferred over 150 mm dia with more than 20 stage pump. 890 2 ) for 150 mm dia energy efficient pumps add as below 891 a. up to 8 stages : 3% on supply rate 892 b. up to 12 stages : 4% on supply rate 893 c. up to 15 stages : 5% on supply rate 894 pressure gauge ( m1056 ) 895 providing fabricating, testing and commisioning pressure vessel fabricating in m.s plate on providing foundation including epoxy paint 896 pressure gauge ( 100 mm dia ) 897 pressure gauge ( 150 mm dia ) 898 vacuum / combination gauge 899 supplyingvacuum gauge / combination gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia g.i. pipe. 900 vacuum / combination gauge – 100 mm dia 901 vacuum / combination gauge – 150 mm dia 902 lifting equipment ( m1057 ) 903 chain pulley block 904 supplyingtriple spur gear type chain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per is 3832 carrying isi mark. 905 1 tonne capacity 906 2 tonne capacity 907 3 tonne capacity 908 hand operated circular or rectangular travelling crane ( single girder ) 909 supplyingsingle girder hand operated circular / rectangular travelling crane with 6 m lift complete with chain pulley block isi marked and travelling trolley both tested for 50% overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete. 910 3 tonne capacity 911 up to 5 m span 912 above 5 m up to 6 m span 913 above 6 m up to 8 m span 914 5 tonne capacity 915 up to 5 m span 916 above 5 m up to 6 m span 917 above 6 m up to 8 m span 918 above 8 m up to 10 m span 919 electric operated circular or rectangular travelling crane ( single girder ) 920 supplying single girder electrically operated rectangular over head travelling crane with 6 m lift complete with wire rope hoist, class ii duty, all three motions electrically operated by suitable rating motor ip 54, control panel and down pendant control block. 921 5 tonne capacity 922 above 6 m up to 8 m span 923 above 8 m up to 10 m span 924 7.5 tonne capacity 925 above 6 m upto 8 m span 926 above 8 m up to 10 m span 927 10 tonne capacity 928 above 6 m up to 8 m span 929 above 8 m up to 10 m span 930 square bar / rail 931 providing, erecting and fixing square bar of en 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and “j” bolts. 932 50 x 50 mm ( en 8 ) 933 40 x 40 mm ( en 8 ) 934 lightening arrester, ab switch, insulators ( m1058 ) 935 lightening arrestor 936 supplying, erecting approved make thyrite type lightening arrestor suitable for h.t. supply with necessary ancillary material complete on provided cross arm and connected to overhead line. 937 suitable for 11 kv supply, distribution class 938 suitable for 22 kv supply, distribution class 939 suitable for 33 kv supply, station class 940 disc insulator 941 supplying, erecting porcelain disc type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 942 suitable for 11kv line 943 suitable for 33kv line 944 pin insulator 945 supplying, erecting porcelain pin type insulators with hardware fittings suitable for h.t. overhead line complete erected with nuts and bolts on provided cross arm 946 suitable for 11kv line 947 suitable for 33kv line 948 air break switch without earth switch 949 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 950 suitable for 11kv line 951 rocking / tilting type 952 rotating type 953 suitable for 33kv line 954 rocking / tilting type 955 rotating type 956 air break switch with earth switch 957 supplying, erecting approved make h.t. outdoor type gang operated air break triple pole switch with earth switch of required capacity with 3 post / pin type insulator per phase , mounted in horizontal or vertical position on provided cross arm with adequate length of g.i. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps 958 suitable for 11kv line 959 rotating type 960 suitable for 33kv line 961 rotating type 962 drop out fuse ( channel mounted ) 963 supplying, erecting approved make out door type drop out fuse channel type with insulator complete with fuse holders fuse barrel with metal fittings, fuse element, with working currentup to 50 amp, capacity completeerected on provided cross arm, each set comprising 3 units 964 suitable for 11 kv line 965 suitable for 33 kv line 966 horn gap fuse ( channel mounted ) 967 supplying, erecting approved make out door type horn gap type fuse with insulator, fuse element, with working current up to 50 amp, capacity complete erected on provided cross arm, each set comprising 3 units 968 suitable for 11 kv line 969 suitable for 33 kv line 970 transformer ( m1059 ) 971 power transformer ( with off load tap changer ) any isi mark 972 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2 nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 973 1. oil conservator with filling hole with cap and plain oil level gauge. 974 2. silica gel dehydrating breather charged with silica gel. 975 3. oil drain valve 976 4. oil filter valve 977 5. lifting eyes / hooks 978 6. two earthing terminals 979 7. diagram and rating plate 980 8. air vent 981 9. explosion vent 982 10. 100mm dia thermo meter with thermometer pocket 983 11. four bi directional plain roller. 984 power transformer 11000 / 433 volts with off load tap changer – 12.5% to +2.5% in steps of 2.5% as per bis level 2. 985 63 kva ( no load loss 180w and load loss 1235w ) 986 100 kva ( no load loss 260w and load loss 1760w ) 987 160kva ( no load loss 260w and load loss 1760w ) 988 200kva ( no load loss 500w and load loss3000w ) 989 250kvaa ( no load loss 550w and load loss3600w ) 990 315kva ( no load loss 580w and load loss 4200w ) 991 400 kva ( no load loss 715w and load loss 5000w ) 992 500 kva ( no load loss 850w and load loss 5800w ) 993 630 kva ( no load loss 1000w and load loss 7000w ) 994 750 kva ( no load loss 1500w and load loss 8000w ) 995 power transformer ( with on load tap changer ) 996 supplyingoutdoor type copper wound transformer continuously rated for 3ph, 50 hz, at full load and temp. rise not exceeding 450 c by thermometer in oil and 500 c by theresistance in winding after continuous run at full load rating, thetransformer should have oil immersed winding having vector group dy11, ht side connected in delta and lt side connected in star with neutral brought out connected to provideseparateearthing. the transformer shall have power terminal arrangement, bushing / cable end box on ht side and cable end box on lt side. 2nos channels with stoppers shall be provided and fixed on the provided plinth for mounting the transformer. the transformer should have following standard fittings. the oltc should be suitable for minimum 50 operations per day. transformer shall be latest manufacturing standards as per amended is specifications and the load & no load losses shall be limited to the values given below or as per is or norms issued by seb which ever are lower 997 1. oil conservator with filling hole with cap and plain oil level gauge. 998 2. silica gel dehydrating breather charged with silica gel. 999 3. oil drain valve 1000 4. oil filter valve 1001 5. lifting eyes / hooks 1002 6. two earthing terminals 1003 7. diagram and rating plate 1004 8. air vent 1005 9. explosion vent 1006 10. 100mm dia thermo meter with thermometer pocket 1007 11. four bi directional plain roller. 1008 12. buchholz relay 1009 13. resistance temp. detector 1010 14. marshalling box 1011 15. automatic voltage regulator ( avr ) 1012 16. remote tap changing controller ( rtcc ) 1013 transformer 11000 / 433 volts withon load tap changer – 15% to +5% in steps of 1.25% with rtcc, avr and marshalling box and other specification as per bis level 2. 1014 750 kva 1015 1000 kva 1016 1250 kva 1017 1600 kva 1018 2000 kva 1019 motors ( m1060 ) 1020 foot mounted motors tefc 1500 rpm 1021 supplyingfoot mounted tefc 1500 rpm, squirrel cage induction motor, conforming to is 325 having continuous rating suitable for operation at 415 volts + / 10%, 3 phase, 50 hz + / 3% with “f” class insulation temperature rise limited to class “b” insulation. motors conform to is 12615 with efficiency level ie3 and provided with enclosure protection class ip 55. 1022 15 kw ( 20 hp ) 1023 18.5 kw ( 25 hp ) 1024 22 kw ( 30 hp ) 1025 30 kw ( 40 hp ) 1026 37 kw ( 50 hp ) 1027 45 kw ( 60 hp ) 1028 55 kw ( 75 hp ) 1029 75 kw ( 100 hp ) 1030 90 kw ( 120 hp ) 1031 110 kw ( 150 hp ) 1032 132kw ( 180hp ) 1033 160kw ( 215 hp ) 1034 250kw ( 335 hp ) 1035 foot mounted motor tefc 1500 rpm 1036 0.75 kw ( 1hp ) 1037 1.1 kw ( 1.5 hp ) 1038 1.5 kw ( 2 hp ) 1039 2.2 kw ( 3 hp ) 1040 3.7 kw ( 5 hp ) 1041 5.5 kw ( 7.5 hp ) 1042 7.5 kw ( 10 hp ) 1043 9.3 kw ( 12.5 hp ) 1044 11 kw ( 15 hp ) 1045 aluminium cable ( m1061 ) 1046 cable 1047 aluminium conductor three core, xlpe / pvc insulated & armoured cable . 1048 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1049 3 core 2.5 sq mm 1050 3 core 4 sq mm 1051 3 core 6 sq mm 1052 3 core 10 sq mm 1053 3 core 16 sq mm 1054 3 core 25 sq mm 1055 3 core 35 sq mm 1056 3 core 50 sq mm 1057 3 core 70 sq mm 1058 3 core 95 sq mm 1059 3 core 120 sq mm 1060 3 core 150 sq mm 1061 3 core 185 sq mm 1062 3 core 240 sq mm 1063 3 core 300 sq mm 1064 3 core 400 sq mm 1065 aluminium conductor 3.5 core, xlpe / pvc insulated & unarmoured cable 1066 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three and half core, stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1067 3.5 core 25 sq mm 1068 3.5 core 35 sq mm 1069 3.5 core 50 sq mm 1070 3.5 core 70 sq mm 1071 3.5 core 95 sq mm 1072 3.5 core 120 sq mm 1073 3.5 core 150 sq mm 1074 3.5 core 185 sq mm 1075 3.5 core 240 sq mm 1076 3.5 core 300 sq mm 1077 3.5 core 400 sq mm 1078 ht aluminium three core 3.3 kve cable xlpe insulated 1079 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1080 3 core 35 sq mm 1081 3 core 50 sq mm 1082 3 core 70 sq mm 1083 3 core 95 sq mm 1084 3 core 120 sq mm 1085 3 core150sq mm 1086 3 core 185 sq mm 1087 3 core 240sq mm 1088 3 core 300 sq mm 1089 3 core 400 sq mm 1090 ht aluminium three core 6.6 kv ( ue ) / 11kv ecable xlpe insulated 1091 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1092 3 core 35 sq mm 1093 3 core 50 sq mm 1094 3 core 70 sq mm 1095 3 core 95 sq mm 1096 3 core 120 sq mm 1097 3 core150sq mm 1098 3 core 185 sq mm 1099 3 core 240sq mm 1100 3 core 300 sq mm 1101 3 core 400 sq mm 1102 ht aluminium three core 11kv ( ue ) cable xlpe insulated 1103 supplying ht aluminium three core cable xlpe insulated , insulation screened with extruded semi conducting compound in combination with copper tape ( 0.3 ka for 1 sec. ) cores laidup inner sheath of pvc tape , galvanised steel flat strip armoured, and overall pvc sheathed cable conforming to is :7098 / ii / 85 with latest amendments 1104 3 core 35 sq mm 1105 3 core 50 sq mm 1106 3 core 70 sq mm 1107 3 core 95 sq mm 1108 3 core 120 sq mm 1109 3 core150sq mm 1110 3 core 185 sq mm 1111 3 core 240sq mm 1112 3 core 300 sq mm 1113 3 core 400 sq mm 1114 aluminium conductor three core, xlpe / pvc insulated & unarmoured cable . 1115 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded aluminium conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1116 3 core 4 sq mm 1117 3 core 6 sq mm 1118 3 core 10 sq mm 1119 3 core 16 sq mm 1120 3 core 25 sq mm 1121 3 core 35 sq mm 1122 3 core 50 sq mm 1123 3 core 70 sq mm 1124 3 core 95 sq mm 1125 3 core 120 sq mm 1126 3 core 150 sq mm 1127 3 core 185 sq mm 1128 3 core 240 sq mm 1129 3 core 300 sq mm 1130 3 core 400 sq mm 1131 copper cable ( m1062 ) 1132 cable 1133 3 core pvc insulated, pvc sheathed copper conductor flat submersible cable . 1134 supplying , flat flexible submersible cable with, copper conductor, pvc insulated, and pvc sheathed . 1135 3 core 1.5 sq mm 1136 3 core 2.5 sq mm 1137 3 core 4 sq mm 1138 3 core 6 sq mm 1139 3 core 10 sq mm 1140 3 core 16 sq mm 1141 3 core 25 sq mm 1142 3 core 35 sq mm 1143 copper conductor three core, xlpe / pvc insulated & unarmoured cable . 1144 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1145 3 core 1.5 sq mm 1146 3 core 2.5 sq mm 1147 3 core 4 sq mm 1148 3 core 6 sq mm 1149 3 core 10 sq mm 1150 3 core 16 sq mm 1151 3 core 25 sq mm 1152 3 core 35 sq mm 1153 3 core 50 sq mm 1154 3 core 70 sq mm 1155 3 core 95 sq mm 1156 copper conductor 3.5 core, xlpe / pvc insulated & armoured cable . 1157 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, completein an approved manner. 1158 3.5 core 1.5 sq mm 1159 3.5 core 2.5 sq mm 1160 3.5 core 4 sq mm 1161 3.5 core 6 sq mm 1162 3.5 core 10 sq mm 1163 3.5 core 16 sq mm 1164 3.5 core 25 sq mm 1165 3.5 core 35 sq mm 1166 3.5 core 50 sq mm 1167 3 .5 core 70 sq mm 1168 3.5 core 95 sq mm 1169 3.5 core 120 sq mm 1170 3 .5 core150sq mm 1171 3.5 core 185 sq mm 1172 3.5 core 240sq mm 1173 3.5 core 300 sq mm 1174 3.5 core 400 sq mm 1175 copper conductor 3.5 core xlpe / pvcunarmoured 1176 supplyingxlpe / pvc insulated, unarmoured cable 1100 v grade with isi mark 3.5 core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1177 3.5core 25 sq mm 1178 3.5core 35 sq mm 1179 3.5 core 50 sq mm 1180 3.5 core 70 sq mm 1181 3.5 core 95 sq mm 1182 3.5 core 120 sq mm 1183 3.5 core150sq mm 1184 3.5 core 185 sq mm 1185 3.5 core 240sq mm 1186 3.5 core 300 sq mm 1187 3.5 core 400 sq mm 1188 copper conductor three core, xlpe / pvc insulated & armoured cable . 1189 supplyingxlpe / pvc insulated, armoured cable 1100 v grade with isi mark three core, solid / stranded copper conductor with 6 mm thick 25 mm width m.s. spacer with g.i. earth wire 6 sq mm, complete in an approved manner. 1190 3 core 1.5 sq mm 1191 3 core 2.5 sq mm 1192 3 core 4 sq mm 1193 3 core 6 sq mm 1194 3 core 10 sq mm 1195 3 core 16 sq mm 1196 3 core 25 sq mm 1197 3 core 35 sq mm 1198 3 core 50 sq mm 1199 3 core 70 sq mm 1200 3 core 95 sq mm 1201 3 core 120 sq mm 1202 3 core 150sq mm 1203 3core 185 sq mm 1204 3 core 240 sq mm 1205 3 core 300 sq mm 1206 3 core 400 sq mm 1207 foot valve ( m1063 ) 1208 foot valve 1209 supplying c.i. foot valve having single leather flap and gunmetal seating. valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. 1210 flanged type 1211 50 mm 1212 65 mm 1213 80 mm 1214 100 mm 1215 125 mm 1216 150 mm 1217 aircircuit breaker ( m1064 ) 1218 acbbreaking capacity 50ka thermal magnetic manual draw out type 3 pole 1219 630a 1220 800a 1221 1000a 1222 1250a 1223 1600a 1224 2000a 1225 starter ( m1065 ) 1226 d.o.l. starter with ss enclosure with 380 / 415 volt coil 1227 7.5 h.p. 1228 10 h.p. 1229 supplyingfully automatic star delta starter to operate induction motor working on415v, 3phase, 50 hz with no volt coil, over load element, on off push buttons, with necessary materials and connected to supply, etc complete starter with original sheet steel encloser 1230 f.a.s.d starter 1231 10.0 h.p. 1232 15 h.p. 1233 20 h.p. 1234 25 h.p. 1235 35 h.p. 1236 40 hp 1237 50 hp 1238 75 h.p. 1239 100 h.p. 1240 125 h.p. 1241 150 h.p. 1242 250 h.p. 1243 servo controlled automatic voltage stabilizer ( m1066 ) 1244 providing, erecting servo controlled automatic voltage stabiliser suitable for out put voltage of 415 volt + / 1%, 3 ph, 50 hz, with copper wound transformer ( air / oil cooled ) as mentioned below. the stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. the stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and users controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, auto / manual selector switch, raise / low push buttons etc. suitable capacity termination strips and bus bars for incoming and out going cable should be provided. all three phases shall be independently monitored and corrected. following protections and indications shall be incorporated over voltage / under voltage single phasing cut off contactor with electronic output sensing unit 1245 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 150 to 450 volt 1246 20 kva air cooled 1247 25 kva air cooled 1248 30 kva air cooled 1249 40 kva air cooled 1250 50 kva oil cooled 1251 60 kva oil cooled 1252 75 kva oil cooled 1253 100 kva oil cooled 1254 125 kva oil cooled 1255 servo controlled automatic voltage stabiliser ( out put 415 + / 1% ) input 280 to 460 volt 1256 15 kva air cooled 1257 20 kva air cooled 1258 25 kva air cooled 1259 30 kva air cooled 1260 40 kva air cooled 1261 50kva air cooled 1262 60 kva oil cooled 1263 75kva oil cooled 1264 100 kva oil cooled 1265 125 kva oil cooled 1266 150 kva oil cooled 1267 200kva oil cooled 1268 250kva oil cooled 1269 300 kva oil cooled 1270 400 kva oil cooled 1271 termination kit ( m1067 ) 1272 providing and errecting in door type termination kit, for 3.3kv / 6.6 kv / 11kv / 22kv / 33kv xlpe screened 3 core cable 1273 in door termination kit for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1274 25 50 mm2 1275 70 120 mm2 1276 150 185 mm2 1277 240 400 mm2 1278 out door termination kit for 3.3 ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1279 25 50 mm2 1280 70 120 mm2 1281 150 185 mm2 1282 240 400 mm2 1283 straight through joint for 3.3kv ( e / ue ) / 6.6 kv ( e ) xlpe 3 core cable 1284 25 50 mm2 1285 70 120 mm2 1286 150 185 mm2 1287 240 300 mm2 1288 in door termination kit for 11kv ( e ) xlpe screened 3 core cable 1289 25 50 mm2 1290 70 120 mm2 1291 150 185 mm2 1292 240 400 mm2 1293 out door termination kit for 11kv ( e ) xlpe screened 3 core cable 1294 25 50 mm2 1295 70 120 mm2 1296 150 185 mm2 1297 240 400 mm2 1298 straight through joint for 11 kv ( e ) xlpe screened 3 core cable 1299 25 50 mm2 1300 70 120 mm2 1301 150 185 mm2 1302 240 300 mm2 1303 in door termination kit for 22kv ( e ) xlpe screened 3 core cable 1304 25 50 mm2 1305 70 120 mm2 1306 150 185 mm2 1307 240 400 mm2 1308 out door termination kit for 22kv ( e ) xlpe screened 3 core cable 1309 25 50 mm2 1310 70 120 mm2 1311 150 185 mm2 1312 240 400 mm2 1313 straight through joint for 22 kv ( e ) xlpe screened 3 core cable 1314 25 50 mm2 1315 70 95 mm2 1316 120 150 mm2 1317 185 240 mm2 1318 300 400 mm2 1319 in door termination kit for 33kv ( e ) xlpe screened 3 core cable 1320 25 50 mm2 1321 70 95 mm2 1322 120 185 mm2 1323 240 400 mm2 1324 out door termination kit for 33 kv ( e ) xlpe screened 3 core cable 1325 25 50 mm2 1326 70 95 mm2 1327 120 185 mm2 1328 240 400 mm2 1329 straight through joint for 33 kv ( e ) xlpe screened 3 core cable 1330 35 70 mm2 1331 95 150 mm2 1332 185 300 mm2 1333 400 mm2...